Users Guide. Electrical Safety Analyzer

Size: px
Start display at page:

Download "Users Guide. Electrical Safety Analyzer"

Transcription

1 180 Electrical Safety nalyzer Users Guide PN May Fluke Corporation, ll rights reserved. Printed in US. Specifications subject to change without notice. ll product names are trademarks of their respective companies.

2 Warranty and Product Support Fluke Biomedical warrants this instrument against defects in materials and workmanship for one year from the date of original purchase. During the warranty period, we will repair or at our option replace, at no charge, a product that proves to be defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty covers the original purchaser only and is not transferable. The warranty does not apply if the product has been damaged by accident or misuse or has been serviced or modified by anyone other than an authorized Fluke Biomedical service facility. NO OTHER WRRNTIES, SUCH S FITNESS FOR PRTICULR PURPOSE, RE EXPRESSED OR IMPLIED. FLUKE SHLL NOT BE LIBLE FOR NY SPECIL, INDIRECT, INCIDENTL OR CONSEQUENTIL DMGES OR LOSSES, INCLUDING LOSS OF DT, RISING FROM NY CUSE OR THEORY. This warranty covers only serialized products and their accessory items that bear a distinct serial number tag. Recalibration of instruments is not covered under the warranty This warranty gives you specific legal rights and you may also have other rights that vary in different jurisdictions. Since some jurisdictions do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. If any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. 07/07

3 Notices ll Rights Reserved Copyright 2007, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications. If you would like other reproductions or distributions, submit a written request to Fluke Biomedical. Unpacking and Inspection Follow standard receiving practices upon receipt of the instrument. Check the shipping carton for damage. If damage is found, stop unpacking the instrument. Notify the carrier and ask for an agent to be present while the instrument is unpacked. There are no special unpacking instructions, but be careful not to damage the instrument when unpacking it. Inspect the instrument for physical damage such as bent or broken parts, dents, or scratches. Technical Support For application support or answers to technical questions, either techservices@flukebiomedical.com or call or Claims Our routine method of shipment is via common carrier, FOB origin. Upon delivery, if physical damage is found, retain all packing materials in their original condition and contact the carrier immediately to file a claim. If the instrument is delivered in good physical condition but does not operate within specifications, or if there are any other problems not caused by shipping damage, please contact Fluke Biomedical or your local sales representative. Standard Terms and Conditions Refunds and Credits Please note that only serialized products and their accessory items (i.e., products and items bearing a distinct serial number tag) are eligible for partial refund and/or credit. Nonserialized parts and accessory items (e.g., cables, carrying cases, auxiliary modules, etc.) are not eligible for return or refund. Only products returned within 90 days from the date of original purchase are eligible for refund/credit. In order to receive a partial refund/credit of a product purchase price on a serialized product, the product must not have been damaged by the customer or by the carrier chosen by the customer to return the goods, and the product must be returned complete (meaning with all manuals, cables, accessories, etc.) and in as new and resalable condition. Products not returned within 90 days of purchase, or products which are not in as new and resalable condition, are not eligible for credit return and will be returned to the customer. The Return Procedure (see below) must be followed to assure prompt refund/credit. Restocking Charges Products returned within 30 days of original purchase are subject to a minimum restocking fee of 15 %. Products returned in excess of 30 days after purchase, but prior to 90 days, are subject to a minimum restocking fee of 20 %. dditional charges for damage and/or missing parts and accessories will be applied to all returns.

4 Return Procedure ll items being returned (including all warranty-claim shipments) must be sent freight-prepaid to our factory location. When you return an instrument to Fluke Biomedical, we recommend using United Parcel Service, Federal Express, or ir Parcel Post. We also recommend that you insure your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost shipments or instruments that are received in damaged condition due to improper packaging or handling. Use the original carton and packaging material for shipment. If they are not available, we recommend the following guide for repackaging: Use a double-walled carton of sufficient strength for the weight being shipped. Use heavy paper or cardboard to protect all instrument surfaces. Use nonabrasive material around all projecting parts. Use at least four inches of tightly packed, industry-approved, shock-absorbent material around the instrument. Returns for partial refund/credit: Every product returned for refund/credit must be accompanied by a Return Material uthorization (RM) number, obtained from our Order Entry Group at or Repair and calibration: To find the nearest service center, go to or In the U.S..: Cleveland Calibration Lab Tel: globalcal@flukebiomedical.com Everett Calibration Lab Tel: service.status@fluke.com In Europe, Middle East, and frica: Eindhoven Calibration Lab Tel: ServiceDesk@fluke.com In sia: Everett Calibration Lab Tel: service.international@fluke.com Certification This instrument was thoroughly tested and inspected. It was found to meet Fluke Biomedical s manufacturing specifications when it was shipped from the factory. Calibration measurements are traceable to the National Institute of Standards and Technology (NIST). Devices for which there are no NIST calibration standards are measured against in-house performance standards using accepted test procedures. WRNING Unauthorized user modifications or application beyond the published specifications may result in electrical shock hazards or improper operation. Fluke Biomedical will not be responsible for any injuries sustained due to unauthorized equipment modifications.

5 Restrictions and Liabilities Information in this document is subject to change and does not represent a commitment by Fluke Biomedical. Changes made to the information in this document will be incorporated in new editions of the publication. No responsibility is assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke Biomedical, or by its affiliated dealers. Manufacturing Location The 180 Electrical Safety nalyzer is manufactured in Everett, Washington by Fluke Biomedical, 6920 Seaway Blvd., Everett, W, U.S..

6

7 Table of Contents Chapter Title Page 1 Introduction and Specifications Introduction Simplicity Versatility General Safety Considerations Symbols Warnings and Cautions Key Features Instrument Familiarity Specifications ccessories Operation, Maintenance, and Service Preliminary Steps Preparing the nalyzer for Use Verifying the Power Outlet Connections Measuring Line Voltage Measuring Device Current Measuring Chassis Grounding Resistance Measuring Leakage Current Ground Leakage Current Chassis (Enclosure) Leakage Current Lead-to-Ground (Patient Source) Current Lead-to-Lead (uxiliary) Current Lead Isolation (Patient Sink) Current Point-to-Point Measurements Leakage Current Isolation Current Resistance Maintenance voiding Damage Cleaning Service and Calibration Packing Instructions Shipping ppendices bbreviations i

8 180 Users Guide ii

9 List of Tables Table Title Page 1-1. Symbols Components and Controls of the nalyzer Standard ccessories Optional ccessories List of Figures Figure Title Page 1-1. Fluke Biomedical 180 Electrical Safety nalyzer Block Diagram of a Typical DUT iii

10 180 Users Guide iv

11 Chapter 1 Introduction and Specifications Contents Page Introduction Simplicity Versatility General Safety Considerations Symbols Warnings and Cautions Key Features Instrument Familiarity Specifications ccessories

12 180 Users Guide 1-2

13 Introduction Introduction and Specifications Introduction 1 The Fluke Biomedical 180 Electrical Safety nalyzer, hereafter referred to as the nalyzer, is a highly versatile and portable instrument. It is used for the basic electrical safety evaluation of electrical systems, medical devices and physiological instrumentation. Its compact handheld size makes it an ideal addition to a service technician or engineer's toolbox for that "after service test" as well as serving as a bench top instrument for the laboratory. It does not sacrifice functions or accuracy, and its low cost permits putting one on each bench. Simplicity The nalyzer is simple to use. single master function switch, directly labeled with the test to be performed, leads the user through a complete measurement procedure. single range meter for each measurement avoids potential erroneous readings. The nalyzer utilizes simple, yet sophisticated, electronics for true-rms measurement of current and voltage. Input impedance uses the MI ES test load to compensate for high frequency components in the measurement. Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length and connector resistance. Versatility Unique to the nalyzer is its capability to make a broad range of point-to-point measurements. These include leakage current and/or voltage gradients and resistance between two points. lso, the nalyzer provides the voltage and measuring provision for the independent measurement of the isolation current of a device. Thus the nalyzer provides the additional versatility for evaluation of electrical systems, system installation, separate components, isolation of probes, transducers, and conventional leakage current measurements. 1-3

14 180 Users Guide General Safety Considerations This instrument and related documentation must be reviewed for familiarization with safety markings and instructions before you operate the instrument. Symbols Table 1-1 describes the symbols used in association with this instrument. Table 1-1. Symbols Symbol Description X W ~ CT I Hazardous voltage Important information; refer to manual. Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. IEC Measurement Category I CT I equipment designed to protect against transients in equipment on circuits not directly connected to MINS. Under no circumstances should the terminals of the nalyzer be connected to any MINS voltage. Warnings and Cautions Warning identifies hazardous conditions and actions that could cause bodily harm or death. Caution identifies conditions and actions that could damage the nalyzer, the equipment under test, or cause permanent loss of data. 1-4

15 Introduction and Specifications General Safety Considerations 1 XW Warning To avoid possible electrical shock or personal injury, follow these guidelines: Disconnect all patient connections before connecting the device to be tested to the analyzer. Continued connection may jeopardize patient safety by possible application of measurement currents. Maintain care when making connections. Isolation test utilizes 120 or 240 V ac applied to patient leads or to external connections that are accessible to the tester. lthough the voltage is current limited by 120 kω resistor per MI test procedure and is safe for healthy intact skin contact, it can be felt and can result in a startle reaction. Ensure the mains installation current rating is adequate for the device under test. If the device under test requires 20, the analyzer must be powered by a 20 service to avoid overloading the mains installation. W Caution To avoid possible damage to the nalyzer, follow these guidelines: Perform the dual lead leakage test only with an optional black test lead with the clamp with the red insulation (Fluke Biomedical part numbers or ) in the jack labeled DUL. Using a black test lead with the clamp with the black insulation in the DUL jack may result in a blown internal fuse and false readings of 000 to 002 μ, requiring the unit to be returned for servicing. Note For point to point measurements, optional accessory cables must be purchased. 1-5

16 180 Users Guide Ensure that the device under test power requirements are within the capabilities of the nalyzer, labeled as 20 at 120 V ac and 10 at 240 V ac. The nalyzer requires that adapter cables match the appropriate connector for line voltages other than 120V. Do not leave the device under test connected and drawing high load current for extended periods. The nalyzer is not designed for continuous measurements and may overheat. lways pause in the off (middle) position when switching polarity from normal to reverse. Inductive loads of the device under test may create high voltage transients when trying to reverse the direction of current flow instantaneously. Key Features Handheld instrument Test power line integrity Line voltage Instrument current Grounding resistance via 4-wire method Ground leakage current Enclosure (chassis) leakage current Patient (lead to ground) leakage current Patient (lead to lead) auxiliary current Patient isolation (sink) current Voltage gradients Device-to-device resistance Device-to-device leakage current Probe and transducer isolation current True-rms measurement MI test load 1-6

17 Instrument Familiarity Introduction and Specifications Instrument Familiarity 1 The nalyzer is shown in Figure 1-1, and Table 1-2 describes its labeled components rl ra OUTLET OK REV POL ELECTRICL SFETY NLYZER la ll C VOLTS 20 MP 5 MINUTES MX E K G µ - DUL - RESISTNCE - GROUND - CHSSIS - LED -GND - LED -LED L E V - LINE VOLTS - CURRENT LED la ll C ISO TEST CHSSIS DUL HZRDOUS LIVE VOLTGE DURING ISO TEST 12 NEUTRL CLOSED all OPEN OPEN GND OUTLET NORML 11 REVERSED OFF Figure 1-1. Fluke Biomedical 180 Electrical Safety nalyzer fat01.eps 1-7

18 180 Users Guide Table 1-2. Components and Controls of the nalyzer Label Name Function B C D E Power Cord Outlet Indicators Test Receptacle Outlet Switch Neutral Switch Supplies power to the Electrical Safety nalyzer and to the device under test (DUT). The measurement circuits are energized when the power cord is plugged into an outlet. There is no on/off switch. Verify the polarity and wiring of the outlet to which the nalyzer is connected. Only correctly wired outlets should be used. Not applicable to isolated power systems. Supplies power to the DUT. This outlet is powered if the OUTLET switch is set to NORML or REVERSED and the NEUTRL switch is CLOSED. If in the center off position, there is no power to the DUT receptacle. This switch permits testing with both normal (forward) and reversed polarity of the line. It is recommended that the switch be paused in the center OFF position before changing polarity. Note: Failure to pause the three-position switch in the OFF position may cause switch damage or blow the internal pico fuse. Permits making leakage current measurements under the OPEN condition as required by UL and IEC. 1-8

19 Introduction and Specifications Instrument Familiarity 1 Table 1.2. Components and controls of the nalyzer (cont.) F G H I J Lift Ground/ISO Test Switch Function Switch Lead Switch Meter Universal Patient Lead Terminals This is a dual-function momentary switch that must be held in position while performing the test. The OPEN GND position will open ground to the device for leakage current measurements. The ISO TEST position will energize the selected patient lead at 110 percent line voltage, current limited, to measure the isolation current when the main FUNCTION switch is in the LED ISO position. With the FUNCTION switch in the DUL position, the isolation test voltage is supplied to the DUL connector for measuring the isolation current of a probe or transducer. Provides direct, one-step selection of the measurement to be made. These are line V ac, instrument current, grounding resistance, ground (internal) and chassis (external) leakage currents, and the patient leakage currents. These include lead to ground (source), lead to lead (auxiliary) and isolation (sink) current. dual position is provided to measure leakage current between two points or isolation current of probes and transducers independent of their instruments. Directs the selected patient lead measurement to the desired lead. When testing a 10-lead device, a second pass will be required for the C leads. This is a large, ½ inch, high-contrast LCD, 3½digit display of the measured parameter. This will read up to 1999 with decimal points added where required. Provide means for connection of the patient leads for leakage current measurement. 1-9

20 180 Users Guide Table 1.2. Components and controls of the nalyzer (cont.) K L Chassis Connector Dual Connector Provides a means for inputting the chassis cable with its clip for connection to the DUT chassis or enclosure. The chassis ground resistance is measured with the FUNCTION switch in the RESISTNCE position, and the chassis leakage current is measured in the CHSSIS position. Used to make point-to-point measurements with optional leads available for purchase. For leakage and voltage measurements, the black cable with the clamp with black insulation is attached to the CHSSIS connector, and the black cable with the clamp with red insulation to the DUL connector. For point-to-point resistance measurements, the black cables with clamps with black insulation are attached to the DUL and CHSSIS connectors. Specifications The following are specifications for the nalyzer. Please contact your Fluke Biomedical service representative for more information regarding the device specifications. Line Voltage Range V ac 50/60 Hz ccuracy... ±3 % of reading, ±1 LSD Load Current Range ccuracy...±5 % of reading, ±1 LSD 1-10

21 Introduction and Specifications Specifications 1 Ground Resistance Range Ω ccuracy... ±1 % of reading, ±1 LSD Range Ω ccuracy... ±3 % of reading, ±1 LSD Current source m dc Type... 4-wire bridge Leakage Current Range μ ccuracy: DC and 25 Hz to 1 khz... ±1 % of reading, ±3 LSD 1.0 khz to 100 khz... ±2.5 % of reading, ±3 LSD 100 khz to 1 MHz... ±5 % of reading, ±3 LSD Type measurement... True rms Impedance Ω, MI ESI 1993 Isolation Test Voltage % Line voltage ±5% Current... limited by 120 kω resistor Current Capacity Line 90 to 140 V ac max. on time 5 min. 15 max. on time 30 min. Line over 140 V ac Current Consumption ES V 60 Hz Environmental Operating Temperature C Storage Temperature C Relative Humidity % max. Mains voltage range to 240 V ac 1-11

22 180 Users Guide ccessories The following are accessories for the nalyzer. To order, contact your Fluke Biomedical equipment dealer and use the Fluke Biomedical part numbers provided. Table 1-3 lists standard accessories shipped with the nalyzer; Table 1-4 lists optional accessories that must be ordered. Table 1-3. Standard ccessories Description Quantity Shipped Part Number Users Guide foot black cable with large clamp with black insulation Table 1-4. Optional ccessories Description 8-foot black cable with large clamp with black insulation (used for dual lead resistance) 16-foot black cable with large clamp with black insulation 8-foot black cable with large clamp with red insulation 16-foot black cable with large clamp with red insulation Part Number Soft carrying case V dapter kit

23 Chapter 2 Operation, Maintenance, and Service Contents Page Preliminary Steps Preparing the nalyzer for Use Verifying the Power Outlet Connections Measuring Line Voltage Measuring Device Current Measuring Chassis Grounding Resistance Measuring Leakage Current Ground Leakage Current Chassis (Enclosure) Leakage Current Lead-to-Ground (Patient Source) Current Lead-to-Lead (uxiliary) Current Lead Isolation (Patient Sink) Current Point-to-Point Measurements Leakage Current Isolation Current Resistance Maintenance voiding Damage Cleaning Service and Calibration Packing Instructions Shipping

24 180 Users Guide 2-2

25 Operation, Maintenance, and Service Preliminary Steps 2 Preliminary Steps The nalyzer measures electrical parameters, as described below. These voltages and currents are a natural phenomenon, and their presence within reasonable limits does not constitute a hazard. However, it is necessary to measure their values to determine if there is a significant change from previous measurements or from the device specifications. Figure 2-1 is a block diagram of a typical line-operated instrument with patient connections. ll measured parameters are labeled, and the following topics are keyed to the labels in the diagram. CL ZI Hot IL Neutral Ground VL RL ZL CL Grounded Data and Control Circuits Isolated Patient Circuits I IE II IP RG Chassis 120/220 VC IC Enclosure Earth Figure 2-1. Block Diagram of a Typical DUT fat02.eps Preparing the nalyzer for Use WX Warning To avoid possible electric shock, burning of the skin, or personal injury to the patient, disconnect all patient connections to the device before starting the following procedure. 2-3

26 180 Users Guide Prepare the nalyzer for use as follows: 1. To start from the same position each time, place the nalyzer's switches in the following starting positions: FUNCTION switch LED switch NEUTRL switch OUTLET switch V- LINE VOLTS RL CLOSED OFF [center] 2. Plug the nalyzer into a properly rated outlet. The nalyzer is equipped with a hospital-grade power plug. Grounding reliability can be achieved only when the nalyzer is connected to an equivalent power receptacle marked "Hospital Grade." Grounding is important for personnel safety and to make some of the tests offered by the nalyzer. Do not circumvent this step for any reason. Verifying the Power Outlet Connections Note Not applicable to isolated power systems. Three neon lamps indicate the polarity and condition of the outlet being used, as shown in the following chart: REV OK Correct wiring Reverse polarity Open ground Open hot Open neutral Hot / ground reversed Note 2-4 Review all power outlets that do not indicate "correct wiring" and have them corrected by a qualified electrician. If the line is found faulty, correct the problem before proceeding. If the line checks OK, plug the device to be tested into the nalyzer's line receptacle.

27 Operation, Maintenance, and Service Measuring Line Voltage 2 WX Warning To avoid electrical shock due to faulty DUT, DO NOT touch the metal chassis, any accessible conductive part, or terminal of the DUT with mains power applied until all applicable tests have been completed and the product is verified as compliant. Keep fingers behind guards on supplied test accessories and/or remove power from the DUT before making necessary connections. Measuring Line Voltage Line Voltage [VL] is the mains power supplied by the electrical distribution system of the hospital. It is a three-wire system of HOT, NEUTRL, and GROUND, with NEUTRL, like GROUND, returned to true earth at their entry into the building. The nalyzer measurement is made between the HOT and NEUTRL wires via transformer coupling to isolate the measuring circuits from the line. s recommended, measurement of the line voltage with the device under test (DUT) OFF and then ON indicates whether the line is adequate for the device. Use the following steps to measure line voltage: 1. From the recommended start position, with the FUNCTION switch in the V - LINE VOLTS position, observe that the meter displays the line voltage with a resolution of one volt. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat03.eps 2. With the OUTLET switch in the NORML position and the DUT turned on, the meter continues to display line voltage, but under the load of the 2-5

28 180 Users Guide device being tested. Depending on the device's operating current and the electrical supply wiring, the voltage differential may be significant. 3. Check the value under load against the device's ratings to ensure that the actual value remains within prescribed limits. n excessive drop also suggests that a dedicated line of increased capacity should be run to the instrument. Measuring Device Current Device, or Instrument, Current [I L ] is the current used by the DUT. When turned on, the device should be operated in its various modes to determine the worst condition to track. Verify that the current of the DUT is within the current rating of the nalyzer being used. Measurement is made in the HOT wire via transformer coupling to ensure that the total current is measured, as it is possible that the NEUTRL and GROUND wire could share the return path. Use the following steps to measure device current: 1. Switch the FUNCTION switch to - CURRENT. The meter displays the device's current to V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat04.eps 2. Place the OUTLET switch in the NORML position; the NEUTRL switch remains in the CLOSED position. 3. Turn on the device and place it in its maximum load condition to obtain the proper reading. 4. Log this data to note changes in values that indicate early problems. 2-6

29 Operation, Maintenance, and Service Measuring Chassis Grounding Resistance 2 Measuring Chassis Grounding Resistance Note This test is only applicable to devices utilizing three-wire (grounded) power cords. Ground Wire Resistance [R G ] (grounding resistance) is the resistance from the device's conductive "grounded" chassis to the grounding terminal on the receptacle into which it is plugged. The resistance is largely composed of the GROUND wire in the power cable and is directly proportional to its length. Use the following steps to measure chassis grounding resistance: 1. Connect the standard cable supplied with unit that has a black cable with the clamp with black insulation to the CHSSIS connector on the front panel of the nalyzer. 2. Clamp the clip of the cable to the DUT's exposed chassis or the enclosure, if conductive. Resistance is measured between the clip on the black chassis cable and the grounding pin receptacle of the nalyzer. Take care to ensure that bare metal is reached and that both jaws of the clip are in contact with the chassis. Metal labels or incidental conductive hardware should not be used for this test. If a non-conducting enclosure is used and no chassis is readily accessible, a safety ground terminal can be used. 3. Once connection is made, rotate the FUNCTION switch to Ω - RESISTNCE and read its value directly in ohms to Ω. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat05.eps 2-7

30 180 Users Guide Note The OUTLET switch should be in the OFF (center) position for this measurement. Measuring Leakage Current Leakage current is the flow of current through or over the surface of an insulating material or insulator. For example, if a person comes in contact with an operational device, leakage current is the amount of current that flows from the point where the person came in contact with the device product, through the person s body, and back to ground. Measurement of leakage current is required on all mains power products. Ground Leakage Current Ground Leakage Current [I E ] (internal chassis current) is the current that flows in the ground wire of the power cable to return the chassis leakage current to true earth ground. It is only applicable to devices utilizing three-wire (grounded) power cords. This current does not constitute a hazard as long as the ground wire remains intact and the current does not become excessive. Leakage current is due to the proximity of the hot wire or line potential components to the chassis represented by Z L, a combination of capacitance, C L, and resistance, R L, components. Note The connection is made internally in the nalyzer, so no external connectors are required for this test. Use the following steps to measure ground leakage current: 1. Set the FUNCTION switch to GROUND. The leakage current is displayed to 1999 μ (microamperes). 2-8

31 Operation, Maintenance, and Service Measuring Leakage Current 2 V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat06.eps 2. Make measurements under all combinations of the OUTLET switch, NORML and REVERSE; the NEUTRL switch CLOSED and OPEN; and with the device power turned ON and OFF. Power to the outlet is OFF when the NEUTRL switch is in the OPEN position. Note Be sure to pause in the OFF (middle) position when switching the OUTLET switch from the NORML to the REVERSE position. Chassis (Enclosure) Leakage Current Chassis [Enclosure] Leakage Current [I C ] flows between the accessible conductive chassis or enclosure and earth (ground) measured through a 1,000 Ω impedance. The nalyzer measures chassis leakage from the exposed metal part on the DUT, through the black cable and the MI load, back to the ground. Use the following steps to measure chassis leakage current: 1. Connect the standard cable (supplied with unit) that has a black cable with the clamp that has black insulation to the CHSSIS connector on the front of the nalyzer. 2. Clamp the clip on the cable in turn to accessible conductive sections of the chassis and the enclosure. Metal labels or incidental conductive hardware are not applicable for this test. If a non-conducting enclosure is used, present standards require connection to the enclosure via a 200 cm² conductive foil in intimate contact with the enclosure. This can be accomplished with a 14 X 14 cm 2-9

32 180 Users Guide (5.5 X 5.5 in) piece of aluminum foil taped to the surface and the cable clipped to the foil. 3. To make the measurement, place the FUNCTION switch in the CHSSIS position and read the display in microamperes. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat07.eps 4. Make measurements under all combinations of the OUTLET switch, NORML and REVERSE; the GROUND switch CLOSED and OPEN; the NEUTRL switch CLOSED and OPEN; and with the device power turned ON and OFF. Power to the outlet is OFF when the NEUTRL switch is in the OPEN position. Note Be sure to pause in the OFF (middle) position when switching the OUTLET switch from the NORML to the REVERSE position. Lead-to-Ground (Patient Source) Current Lead-to-Ground [I P ] (patient source) current would flow between an individual patient lead and ground if the patient were to come into contact with earth ground. n example is a patient with leads attached touching ground such as an electric bed Note lthough originally required only for devices incorporating intracardiac electrodes or conductive pathways directly to the heart, leadto-ground current has found its way into standards for all devices having patient-applied parts.

33 Operation, Maintenance, and Service Measuring Leakage Current 2 Use the following steps to measure lead-to-ground current: 1. Connect the patient leads to the corresponding snaps on the top of the nalyzer. If the device has 10 leads, connect the limb leads and C1 (V1) initially and repeat with C2 (V2) through C6 (V6). Lead nomenclature for this test is not important. 2. Select LED-GND with the FUNCTION switch and read leakage current in microamperes for any combination of the patient lead selected by the LED switch. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat08.eps 3. Make measurements under all combinations of the OUTLET switch, NORML and REVERSE; the LIFT GROUND switch CLOSED and OPEN; and the device power turned ON and OFF. 4. Rotate the LED switch to each lead to test individually and then to LL for testing with all leads connected together. LED rl ra la ll c all fat17.eps Current measured should be the same for all leads, including the LL position, as the current represents the isolation impedance to the patient circuit. 2-11

34 180 Users Guide Lead-to-Lead (uxiliary) Current Lead-to-Lead [I ] (auxiliary) current flows from any patient lead to any other patient lead and to all other leads connected together. The current can be dc or ac or a combination of both. Measurements are made with a true-rms converter to provide the common base necessary for accurate readout with a variety of common wave forms. Under normal conditions, the current is primarily input bias current, measurement current, or lead off sensing current. The worst-case condition is measured from the individual lead to all others connected together. This is the measurement made by the nalyzer. Use the following steps to measure lead-to-lead current: 1. Connect the patient leads to the snaps on top of the nalyzer. 2. Set the FUNCTION switch in the LED-LED position. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat09.eps 3. Make readings for individual leads, selecting by the LED switch. The single lead carrying the most current is the reference lead, R L, acting as the return for the other leads. LED rl ra la ll c all fat12.eps 2-12

35 Operation, Maintenance, and Service Measuring Leakage Current 2 Note The LL position has no meaning in this test. 4. Make measurements under all combinations of the OUTLET switch, NORML and REVERSE; GROUND CLOSED and the LIFT GROUND switch OPEN; and the device power turned ON and OFF. 5. If the DUT utilizes a 10-lead patient input, test each C (V) lead in turn, individually. Lead Isolation (Patient Sink) Current Lead Isolation [I I ] (patient sink) current would flow into the DUT if the patient were to come into contact with full line voltage. n example is an electric bed that has become ungrounded and has a short to the frame. WX Warning To avoid possible electric shock, burning of the skin, or personal injury to the patient, take care when handling the patient leads. High voltage, 110 percent of line volts, with respect to earth ground is accessible at the patient connections (snaps) during part of this test. The patient lead isolation current can flow in individual leads or all leads connected together if line volts come into contact with the patient. Use the following steps to measure lead isolation current: 1. ttach the patient leads to the snaps on top of the nalyzer, making sure that ground is intact. 2. Set the FUNCTION switch in the LED ISO position. 2-13

36 180 Users Guide V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat10.eps 3. Test individual leads, selecting by the LED switch. 4. To apply the high voltage to the lead safely, press the LIFT GROUND/ISO TEST switch to ISO TEST. The current is limited with a 120 kω resistor for user protection. 5. While ISO TEST is energized, read the isolation current in microamperes. 6. Perform the test using the OUTLET switch in both NORML and REVERSE, the NEUTRL switch CLOSED, and with the DUT ON and OFF. Point-to-Point Measurements The nalyzer provides the capability of making point-to-point leakage current, isolation current, and resistance measurements between selected points, otherwise known as a dual lead measurement. Note dditional optional accessory cables must be purchased to perform these tests. Leakage Current Leakage Current between two points is also measured for permanently installed equipment as additional verification of the integrity of the installation. These measurements are equivalent, as the relationship between volts and current across 1,000 Ω is one mv per μ. 2-14

37 Operation, Maintenance, and Service Point-to-Point Measurements 2 Use the following steps to measure leakage current between two points: 1. To isolate the measurement circuit from ground, do not plug any device into the nalyzer's receptacle. 2. Connect the black cable with the clamp with black insulation to the CHSSIS connector and the black cable with the clamp with red insulation to the DUL connector. 3. Set the FUNCTION switch in the DUL position. V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat11.eps 4. Clip the two cables to the two points for which the leakage current is to be measured. The meter displays the leakage current between the two points to 1999 µ. The number displayed is also the voltage gradient in millivolts between the two points based on a volt meter with an input impedance of 1000 Ω. Isolation Current Isolation testing of probes and transducers making internal contact to a patient is provided to ensure the reliability of the isolation barrier. These devices incorporate electrical circuits that can introduce or sink hazardous currents to a patient who comes into contact with line potential or who becomes grounded, as previously described. Use the following steps to measure isolation current between two points: 1. To isolate the measurement circuit from ground, do not plug any device into the nalyzer's receptacle. 2-15

38 180 Users Guide 2. Connect the black cable with the clamp with black insulation to the CHSSIS connector and the black cable with the clamp with red insulation to the DUL connector. 3. Toggle the LIFT GROUND/ISO TEST switch to ISO TEST to apply isolated line voltage between the two sides. The meter displays the isolation current that flows. Note The actual method for making connection to either side of the isolation barrier varies with the device to be tested; therefore, full details are not provided. W X Warning To avoid possible electric shock, burning of the skin, or personal injury take care when handling the cables. High voltage, 110 percent of line volts, will be accessible between the two cables when the LIFT GROUND/ISO TEST switch is in the ISO TEST position. Resistance Resistance measurements between two points are made to verify the integrity of permanently installed equipment whose ground cannot be broken to measure the chassis leakage current. These are usually high-power devices that can have high leakage currents and depend on the bonding of all chassis to a common point for safety. To measure resistance between two points, follow the steps below: 1. Disconnect any device attached to the nalyzer instrument receptacle. 2. Turn off any electrical devices to be tested. 3. Connect two black cables with clamps with black insulation to the CHSSIS and DUL connectors, and clip onto the two points to be measured. 4. Set the FUNCTION switch to Ω - RESISTNCE, and the display will show the resistance between the two points. 2-16

39 Operation, Maintenance, and Service Maintenance 2 V - LINE VOLTS - CURRENT - RESISTNCE L - GROUND E - CHSSIS K - LED -GND G - LED -LED E - LED ISO µ - DUL fat05.eps 5. To compensate for possible dc components in the leakage current flowing between the two points, reverse the two clips and average the readings. Maintenance The nalyzer requires little maintenance or special care; however, it is a calibrated measuring instrument and should be treated as such. The following describes how to maintain the nalyzer. voiding Damage Do not drop the instrument or subject it to any mechanical abuse that could cause a shift in the calibrated settings. W Caution To avoid damage to the nalyzer or adverse affects on its performance, follow these guidelines: Do not expose the system to temperature extremes. mbient temperatures should remain between 15 C and 40 C. System performance may be adversely affected if temperatures fluctuate above or below this range. Cleaning Clean the exterior of the nalyzer occasionally with a cloth dampened with a mild detergent solution. Take care to keep liquids out of the device. 2-17

40 180 Users Guide W Caution To avoid damage to the nalyzer or adverse affects on its performance, clean it only by gently wiping down with a clean, lint-free cloth dampened with a mild detergent solution. Do not spray liquids on or immerse the unit. Carefully wipe down the cables and inspect them for damage and deterioration of the insulation. Check the cable connections for integrity of the cable clamp and strain relief. Service and Calibration If your new nalyzer fails to operate successfully, please contact Fluke Biomedical Service Center immediately, as indicated under Warranty and Product Support. W Caution To avoid damage to the nalyzer or adverse affects on its performance, allow only qualified technical personnel to service the nalyzer. nnual calibration of the nalyzer by an authorized Fluke Biomedical Service Center is recommended. Fluke Biomedical Service Centers have the appropriate tools and procedures for performing calibrations as well as factoryauthorized updates. International customers should contact their Fluke Biomedical dealers for service/product support. To obtain the name of your local dealer or service center, contact Fluke Biomedical as indicated under Return Procedures, Repair and calibration. Packing Instructions If repairs are required, return the nalyzer to the factory or the nearest service center, as follows: 1. Before returning the nalyzer for factory service, contact the Fluke Biomedical Service Center for a required Return uthorization Number. 2. Provide the following information: 2-18

41 Operation, Maintenance, and Service Service and Calibration 2 The nalyzer serial number The specific steps that reproduce your problem daytime phone number Your name/company fax number (if available) 3. Pack the instrument carefully, using the original packing materials. If the original packing materials are not available, refer to Return Procedures for a list of preferred materials or contact Fluke Biomedical for replacement packing. Failure to pack the instrument properly could void your warranty. Shipping 1. Place the Return uthorization Number in a prominent place on the outside of the packing box, and refer to the number in any correspondence with Fluke Biomedical Service. 2. Enclose your return address and Return uthorization Number. 3. Insure the unit for full retail value and ship to the nearest Fluke Biomedical service center. 2-19

42 180 Users Guide 2-20

43 ppendices ppendix Title Page bbreviations... -1

44 180 Users Guide

45 ppendix bbreviations bbreviations The following list includes abbreviations used in this document. NSI MI db ampere merican National Standards Institute ssociation for the dvancement of Medical Instrumentation decibel C degrees Celsius (centigrade) DUT ECG EUT device under test electrocardiograph or electrocardiogram equipment under test F degrees Fahrenheit Hz in hertz inch k kilo (10 3 ) khz kω LED kilohertz kilohm light-emitting diode M meg(a) (10 6 ) MHz MΩ megahertz megohm -1

46 180 Users Guide m meter m milli (10-3 ) m mm mv s milliampere millimeter millivolt second µ micro (10-6 ) µ microampere µv microvolt Ω ohm -2

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG

More information

ESA620. Users Manual. Electrical Safety Analyzer

ESA620. Users Manual. Electrical Safety Analyzer ESA620 Electrical Safety Analyzer Users Manual January 2008 2008 Fluke Corporation, All rights reserved. Specifications subject to change without notice. All product names are trademarks of their respective

More information

INSTRUCTION MANUAL LKG

INSTRUCTION MANUAL LKG INSTRUCTION MANUAL LKG 610 Electrical Safety Analyzer With 10 ECG Connectors 110 Toledo Street Farmingdale, NY 11735 USA Homepage: www.netech.org Dear User, We appreciate your purchase of the LKG 610 Electrical

More information

ESA620. Users Manual. Electrical Safety Analyzer

ESA620. Users Manual. Electrical Safety Analyzer ESA620 Electrical Safety Analyzer Users Manual FBC-0028 January 2008, Rev. 2, 3/13 2008, 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names

More information

ESA609. Users Manual. Electrical Safety Analyzer

ESA609. Users Manual. Electrical Safety Analyzer ESA609 Electrical Safety Analyzer Users Manual FBC-0060 February 2014, Rev. 1 2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

ESA620. Electrical Safety Analyzer

ESA620. Electrical Safety Analyzer PN 2814971 January 2008, Rev. 3, 5/15 2008-2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

More information

ELECTROSURGICAL UNIT ANALYZER

ELECTROSURGICAL UNIT ANALYZER ELECTROSURGICAL UNIT ANALYZER ESU-2000A USER MANUAL BC BIOMEDICAL ESU-2000A TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 OVERVIEW... 2 OPERATING INSTRUCTIONS... 3 MANUAL REVISIONS...

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

ECG PATIENT SIMULATOR FIVE LEAD

ECG PATIENT SIMULATOR FIVE LEAD ECG PATIENT SIMULATOR FIVE LEAD PS-2005 USER MANUAL BC BIOMEDICAL PS-2005 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394 User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

80i-600A AC Current Probe

80i-600A AC Current Probe x Instruction Sheet 80i-600A AC Current Probe INTRODUCTION The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes. A

More information

ECG PATIENT SIMULATOR SIX LEAD

ECG PATIENT SIMULATOR SIX LEAD ECG PATIENT SIMULATOR SIX LEAD PS-2006 USER MANUAL BC BIOMEDICAL PS-2006 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394 User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

742A Series Resistance Standards

742A Series Resistance Standards 742A Series Resistance Standards Instruction Manual PN 850255 September 1988 Rev. 1, 4/89 1988-2015 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

More information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009 User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent

More information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This

More information

16 Multimeter with Temperature

16 Multimeter with Temperature 16 Multimeter with Temperature Instruction Sheet P Read First: Safety Information To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP016 Passive Probe Operator s Manual PP016 Passive Probe 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11

More information

Operator s Manual. PP017 and PP018 Passive Probes

Operator s Manual. PP017 and PP018 Passive Probes Operator s Manual PP017 and PP018 Passive Probes 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com PP017 and PP018 Passive Probes Operator

More information

Autoranging Multimeter Extech EX503

Autoranging Multimeter Extech EX503 User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

PULSE OXIMETRY SIMULATOR

PULSE OXIMETRY SIMULATOR PULSE OXIMETRY SIMULATOR SPO-2000 SYSTEM USER MANUAL BC BIOMEDICAL SPO-2000 SYSTEM TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 KEYS... 3 LED INDICATORS... 4 OPERATIONS...

More information

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information 36 / True RMS Clamp Meter Instruction Sheet P Read First: Safety Information To ensure safe operation and service of the meter, follow these instructions: Avoid working alone so assistance can be rendered.

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i310s AC/DC Current Clamp Instruction Sheet Introduction The i310s Current Clamp ( Clamp ) has been designed for use with oscilloscopes and digital multimeters for accurate nonintrusive measurement of

More information

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP022 Passive Probe Operator s Manual PP022 Passive Probe 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com PP022 Passive Probe Instruction Manual 2017 Teledyne

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

Model 7000 Low Noise Differential Preamplifier

Model 7000 Low Noise Differential Preamplifier Model 7000 Low Noise Differential Preamplifier Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Broadband Step-Up Transformer. User Manual

Broadband Step-Up Transformer. User Manual Broadband Step-Up Transformer User Manual 990-1930 09/2004 Introduction Introduction About this unit The APC Step-Up Transformer provides 220 V power from 60 VAC Broadband cable systems. Safety Electrical

More information

User s Manual. Ground Resistance Clamp On Tester MODEL

User s Manual. Ground Resistance Clamp On Tester MODEL User s Manual Ground Resistance Clamp On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION warrants the basic instrument to be free of defects in parts and workmanship for one year from date

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

Electrical Multimeter

Electrical Multimeter 113 Electrical Multimeter Instruction Sheet Safety Information A Warning statement identifies hazardous conditions and actions that could cause bodily harm or death. A Caution statement identifies conditions

More information

16 Multimeter with Temperature

16 Multimeter with Temperature 16 Multimeter with Temperature P Read First: Safety Information Instruction Sheet To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear

More information

374/375/376 Clamp Meter

374/375/376 Clamp Meter 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

12B/18 MultiMeter Instruction Sheet

12B/18 MultiMeter Instruction Sheet 12B/18 MultiMeter Instruction Sheet P Read First: Safety Information To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear damaged,

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Test Equipment Auto Meter Products Inc. 413 West Elm Street Sycamore, IL 60178 Service (815) 899-0801 Toll Free (866) 883-TEST (8378) www.autometer.com/test DM-46 Instruction Manual Automotive Multimeter

More information

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,

More information

374/375/376 Clamp Meter

374/375/376 Clamp Meter 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA CANARY AUDIO 300B Push-Pull Parallel Power Amplifier Mono Block Handcrafted in California CA-309 OWNER S MANUAL MADE IN USA Dear Customer: Please allow us to take this opportunity to thank you for purchasing

More information

INSTRUCTION MANUAL UTL260

INSTRUCTION MANUAL UTL260 INSTRUCTION MANUAL UTL260 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The UTL260 has all the features and measurement functions that appliance technicians need.

More information

netzerotools.com 374/375/376 Users Manual Clamp Meter

netzerotools.com 374/375/376 Users Manual Clamp Meter 374/375/376 Clamp Meter Users Manual Fluke 376 True RMS AC DC Clamp Meter Fluke 374 True RMS AC / DC Clamp Meter Fluke 373 True RMS AC Clamp Meter Fluke 375 True RMS AC / DC Clamp Meter LIMITED WARRANTY

More information

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications...

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

Glass Electrode Meter

Glass Electrode Meter Glass Electrode Meter INSTRUCTION MANUAL FOR Glass Electrode R/C Meter MODEL 2700 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com

More information

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4

More information

374/375/376. Calibration Manual. Clamp Meter

374/375/376. Calibration Manual. Clamp Meter 374/375/376 Clamp Meter Calibration Manual December 2010 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and

More information

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC PD5-RM-B PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview Model 4210-MMPC-W Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 28775 urora Road Quick Start Guide Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

MODEL W Power Amplifier

MODEL W Power Amplifier TEGAM, INC. MODEL 2348 18.75 W Power Amplifier This owner s manual was as current as possible when this product was manufactured. However, products are constantly being updated and improved. Because of

More information

R-X SERIES. Decade Resistor

R-X SERIES. Decade Resistor PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT R-X SERIES Decade Resistor User and Service Manual Effectivity: Serial Numbers beginning with P2 RX im/august, 2002 Copyright 2002 IET Labs, Inc. IET LABS,

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual Dawson DDM181 Pocket-Size Autorange Digital Meter User s Manual 1 Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Important Safety Information...

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

TA MHz oscilloscope probe TA MHz oscilloscope probe

TA MHz oscilloscope probe TA MHz oscilloscope probe TA375 100 MHz oscilloscope probe TA386 200 MHz oscilloscope probe User's Guide X1 X10 TA386 X1/X10 Max. 600 Vp Introduction This passive high-impedance oscilloscope probe is suitable for most oscilloscopes

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

374 FC/375 FC/376 FC Clamp Meter

374 FC/375 FC/376 FC Clamp Meter 374 FC/375 FC/376 FC Clamp Meter PN 4705494 September 2015 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

DMM8900 SERIES USERS MANUAL

DMM8900 SERIES USERS MANUAL DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA560D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

Model 4007DDS. 7 MHz Sweep Function Generator

Model 4007DDS. 7 MHz Sweep Function Generator Model 4007DDS 7 MHz Sweep Function Generator 1 Model 4007DDS - Instruction Manual Limited Two-Year Warranty B&K Precision warrants to the original purchaser that its products and the component parts thereof,

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. INSTRUCTION MANUAL Model 403380 Autoranging DMM ProbeMeter TM Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. Back lit LCD with Autorange and full function displays Audible

More information

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA604D DA954D DA501D DA801D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it

More information

Model 9305 Fast Preamplifier Operating and Service Manual

Model 9305 Fast Preamplifier Operating and Service Manual Model 9305 Fast Preamplifier Operating and Service Manual This manual applies to instruments marked Rev 03" on rear panel. Printed in U.S.A. ORTEC Part No.605540 1202 Manual Revision B Advanced Measurement

More information

True RMS AC / DC Power Clamp Meter Model

True RMS AC / DC Power Clamp Meter Model User's Guide True RMS AC / DC Power Clamp Meter Model 380940 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

15B & 17B. Users Manual. Multimeters

15B & 17B. Users Manual. Multimeters 15B & 17B Multimeters Users Manual PN 1991246 October 2002 Rev. 3, 3/04 2002-2004 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

More information

AT Advanced Wire Tracer. Users Manual

AT Advanced Wire Tracer. Users Manual AT-1000 Advanced Wire Tracer Users Manual AT-1000 Advanced Wire Tracer English Users Manual AT1000_Rev001 2008 Amprobe Test Tools. All rights reserved. Limited Warranty and Limitation of Liability Your

More information

Technical data ESA614 Electrical Safety Analyzer

Technical data ESA614 Electrical Safety Analyzer Technical data ESA614 Electrical Safety Analyzer The ESA614 Electrical Safety Analyzer brings fast and simple automated testing in the form of a portable analyzer to healthcare technology professionals

More information

USER'S MANUAL DMR-4350

USER'S MANUAL DMR-4350 USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer User's Guide Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer EX810 AC Clamp meter EX820 True RMS AC Clamp meter EX830 AC/DC True RMS Clamp meter Patented Introduction Congratulations on your

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

MICRO SERIES MONITORS

MICRO SERIES MONITORS LTO R OWNER'S MANUAL MICRO SERIES MONITORS PASSIVE & ACTIVE MODELS www.altoproaudio.com Version. SEPTEMBER 007 English IMPORTANT SAFETY INSTRUCTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE

More information

1523, 1524 Thermometer Readout User s Guide

1523, 1524 Thermometer Readout User s Guide 1523, 1524 Thermometer Readout User s Guide ThermoWorks Inc. 1762 W. 20 S. #100 Lindon, UT 84042 Phone: 801.756.7705 Fax: 801.756.8948 Email: info@thermoworks.com Web: www.thermoworks.com Rev. 891001_EN

More information

MODEL: D03128 CLAMP METER

MODEL: D03128 CLAMP METER MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications

More information

1507/1503. Insulation Testers. Users Manual

1507/1503. Insulation Testers. Users Manual 1507/1503 Insulation Testers Users Manual June 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

Handheld Digital Multimeter PRO-50A

Handheld Digital Multimeter PRO-50A Handheld Digital Multimeter PRO-50A Safety Summary A statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.

More information

DCM730. Digital Clamp Meter User s Manual

DCM730. Digital Clamp Meter User s Manual DCM730 Digital Clamp Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY...1 Out of the Box...1 Safety Information...2 INTRODUCTION...4 Components and Buttons...6 Names of

More information

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present. 9305 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates

More information

Amplifier Series BASIC. Installation & Operations Manual

Amplifier Series BASIC. Installation & Operations Manual Amplifier Series BASIC Installation & Operations Manual Bittner-Audio 200 Power Amplifier Series BASIC Bittner - Audio September 200 200 Bittner-Audio. All Rights Reserved. Bittner-Audio reserves specification

More information

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc User s Guide RP1000D Series High Voltage Differential Probe Feb. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2012 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

More information

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA CANARY AUDIO EL34 Stereo Power Amplifier Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA Dear Customer: Please allow us to take this opportunity to thank you for purchasing this CANARY AUDIO

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV. TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350 Instruction Manual PN# 810044-CD Publication Date: June 2006 REV. C This owner s manual was as current as possible when this product

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information