CALEC ST II BACnet MS/TP
|
|
- Eustace Shields
- 6 years ago
- Views:
Transcription
1 Communication description Page 2 9 CALEC ST II BACnet MS/TP Table of contents 1 General information Content Definition Registered trademark and brand names Certification according to BACnet standard Hardware Communication interface Line termination Commissioning Commissioning of CALEC ST II with the BACnet MS/TP interface BACnet Baud rate BACnet MAC address Master/slave mode Device instance number (DIN) Device object name Location Description CALEC ST II BACnet services and objects Supported BACnet services Supported BACnet objects BACnet connections, e.g. with water and oil meters Alarm PICS document Troubleshooting... 9 VD 3-125b e
2 1 General information 1.1 Content This communication description includes only specific information about CALEC ST II with the BACnet MS/TP module. Further information is available in the technical documentation of CALEC ST II. Additional documents can be found on the following website: General information about BACnet can be found at Definition BACnet is a globally accepted, open standard (ISO Standard ) in building automation. BACnet assures the inter-operability between devices of different manufacturers. CALEC ST II with BACnet MS/TP interface allows an integration in BACnet networks without using gateways. The physics of RS485 interface is used for transmission. 1.3 Registered trademark and brand names BACnet, as well as the BACnet logo are registered trademarks of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) in Atlanta, GA (USA). 1.4 Certification according to BACnet standard CALEC ST II with the BACnet MS/TP module is certified according to the following test standards: Test standards ISO :2014 ANSI/ASHRAE Addendum ai to ANSI/ASHRAE Addendum al to ANSI/ASHRAE Addendum ar to ANSI/ASHRAE Addendum as to ANSI/ASHRAE Addendum ay to ANSI/ASHRAE Addenda an, at, au, av, aw, ax, and az to ANSI/ASHRAE ANSI/ASHRAE Addendum o to ANSI/ASHRAE BTL Test Plan 14.0 BTL Specified Tests 14.0 BTL Checklist CALEC ST II
3 2 Hardware 2.1 Communication interface INTEGRA METERING AG uses a communication interface defined by BACnet technology with twisted-pair wiring (2-core). CALEC ST II: Overview of supported functions Function Parameter Value description More information Manufacturer ID This identification is valid for INTEGRA METERING AG and Aquametro AG Data protocol BACnet MS/TP - - BACnet device profile B-ASC - - MAC address master and slave slave Factory setting: the last 2 digits of the device serial no. Master/slave setting: Changeable via CALEC ST II operating menu. Factory setting: master See: Chapter 3.4 Master/slave mode Baud rate 9600, 19200, 38400, 57600, 76800, Automatic adjustment See: Chapter 3.2 BACnet Baud rate Device instance number - The last 5 digits of the device serial no. See: Chapter 3.5 Device instance number (DIN) BACnet connection type - RS Line termination A termination resistor must be connected to both ends of the segment. The technical BACnet MS/TP specifications recommend a 120 Ohm resistor. If CALEC ST II is at the end of a segment, the internal termination resistor can be activated. Operating menu: BAcnEt TRm CALEC ST II 3
4 3 Commissioning 3.1 Commissioning of CALEC ST II with the BACnet MS/TP interface After connecting the RS-485 cable with the terminals 90a(+) and 91b(-), the following steps need to be performed: Step-by-step instructions Step Action Description 1 Configuration of CALEC ST II for use of application The respective information can be found in the operating instructions of CALEC ST II. 2 Configuration of CALEC ST II for BACnet use According to this description The relevant bus number for the configuration results from the assembly of the BACnet interface in socket # 1 or socket # BACnet Baud rate The baud rate adjustment of CALEC ST II will be set automatically after connecting the BTU meter to the network. Supported baud rates are 9600, 19200, 38400, and If the Baud rate is changed at the master system during operation, CALEC ST II needs to be restarted. 3.3 BACnet MAC address The BACnet MS/TP MAC address can be changed in the operating menu of CALEC ST II. The applicable range of the BACnet MS/TP MAC address lies between 0 and 254 (for master functionality between 0 and 127, for the slave functionality between 0 and 254). The differentiation between master and slave address range is defined via the operating menu in the menu Mod of CALEC ST II. Operating menu: BAcnEt Adr 3.4 Master/slave mode By means of the BACnet MS/TP mode selection the mode behaviour of CALEC ST II can be selected as master or slave. After 30 seconds the change is active. Operating menu: BAcnEt Mod 3.5 Device instance number (DIN) The device instance number can be changed in the operating menu of CALEC ST II. The last 5 digits of the serial number (CALEC ST II) are the factory setting for the DIN. Operating menu: BAcnEt DIN 4 CALEC ST II
5 3.6 Device object name The parameter object-name can be overwritten (standard: Calec ST II BACnet ) 3.7 Location The parameter location can be overwritten (standard: No Location set ) 3.8 Description The parameter description can be overwritten (standard: CALEC BTU METER ) 4 CALEC ST II BACnet services and objects 4.1 Supported BACnet services CALEC ST II is a BACnet Application Specific Controller (B-ASC) and supports the following services: BACnet Interoperability Building Blocks (BIBB s) Data Sharing - ReadProperty - B Data Sharing - ReadPropertyMultiple - B Data Sharing - WriteProperty - B Data Sharing WritePropertyMultiple - B Data Sharing - COV - B Device Management - Dynamic Device Binding - B Device Management - Dynamic Object Binding - B Device Management - DeviceCommunicationControl - B Device Management - TimeSynchronization - B Device Management - UTCTimeSynchronization - B Device Management - ReinitializeDevice - B DS-RP-B DS-RPM-B DS-WP-B DS-WPM-B DS-COV-B DM-DDB-B DM-DOB-B DM-DCC-B DM-TS-B DM-UTC-B DM-RD-B CALEC ST II 5
6 4.2 Supported BACnet objects CALEC ST II with BACnet MS/TP supports the following device objects and variants and their analog inputs. The analog inputs are made available according to the respective device variants. Analog inputs Object no. Designation Volume Mass Flow BDE TGR BDV DTF AI-0 Energy X X X X X X AI-1 Energy-BDE X X X X AI-2 Volume X X X X X AI-3 Volume-BDE X X X AI-4 Mass X AI-5 Auxiliary counter 1 X AI-6 Auxiliary counter 2 X X X X X X X AI-7 Auxiliary counter 3 X X X X X AI-8 Power X X X X X X AI-9 Volume flow X X X X X X AI-10 Mass flow X AI-11 Temperature warm X X X X X X AI-12 Temperature cold X X X X X X AI-13 Temperature difference X X X X X X AI-14 Density X X X X X X AI-15 Energy-TGR X Binary outputs Object no. Designation Volume Mass Flow BDE TGR BDV DTF BO-0 Relay 1 X X X X X X X BO-1 Relay 2 X X X X X X X 6 CALEC ST II
7 4.2.1 Supported BACnet units of current values CALEC ST II with BACnet MS/TP supports the following units for current values: Energy and Energy-BDE/TGR units Volume and Volume-BDE units Unit BACnet Enum Unit BACnet Enum J 16 cft 79 kj 17 m 3 80 kj/kg 125 Imp.gal. 81 MJ 126 L 82 Wh 18 US.gal. 83 kwh 19 MWh 146 BTU 20 kbtu 147 MBTU 148 thm 21 Th 22 Mass units Unit kg 39 lb 40 Tons 41 BACnet Enum Supported BACnet units of the auxiliary counters The selectable units depend on the setting of the auxiliary counter in CALEC ST II. Energy-related Volume-related Unit BACnet Enum Unit BACnet Enum J 16 cft 79 kj 17 m 3 80 kj/kg 125 Imp.gal. 81 MJ 126 L 82 Wh 18 US.gal. 83 kwh 19 MWh 146 BTU 20 kbtu 147 MBTU 148 thm 21 Th 22 Mass-related Without unit Unit BACnet Enum Unit BACnet Enum kg 39 Without unit 95 lb 40 Tons 41 CALEC ST II 7
8 4.2.3 Supported BACnet units instant values CALEC ST II with BACnet MS/TP supports the following units for instant values: Power units Volume flow units Unit BACnet Enum Unit BACnet Enum mw 132 cft/s 142 W 47 cft/min 84 kw 48 m 3 /s 85 MW 49 m 3 /min 165 BTU/h 50 m 3 /h 135 kbtu/h 157 Imp.gal./min 86 PS 51 l/s 87 RT 52 l/min 88 l/h 136 US.gal./min 89 Mass flow units Temperature units Unit BACnet Enum Unit BACnet Enum g/s 154 C 62 g/min 155 K 63 kg/s 42 F 64 kg/min 43 kg/h 44 lb/s 119 lb/min 45 lb/h 46 Tons/h 156 Temperature difference units Unit BACnet Enum K 63 8 CALEC ST II
9 5 BACnet connections, e.g. with water and oil meters There are two auxiliary inputs available to measure pulses from other meters, such as water and oil meters with pulse signals and to directly communicate the result to the BACnet MS/TP network. 6 Alarm CALEC ST II status messages are linked with the BACnet objects. INTEGRA METERING AG differs between the following types of status messages: Device status error All important device errors such as system error need to be verified including their error codes. Measurement value status alarm : Specific messages such as dt alarm have to be verified (further information can be found in the section Error messages, alarms in the operating instructions of CALEC ST II). 7 PICS document The PICS document of CALEC ST II can be found at Additional documents can be found on the following website: 8 Troubleshooting Communication errors No. Error / malfunction Possible reason Correction 1 CALEC ST II is not communicating in the BACnet MS/TP network 2 After changing the Baud rate on the master system, CALEC CALEC ST II is not communicating via BACnet MS/TP anymore Wiring of the network Terminating resistors Configuratin of CALEC ST II Configuration of BMS CALEC ST II is unable to automatically recognise the set Baud rate Check if the BACnet MS/TP devices are correctly connected. Check, if the termination and bus topology are correct. Check, if the BACnet MAC address and the device instance number are correctly configured and unique within the network Restart CALEC ST II by switching the power supply off and on again. CALEC ST II runs through an initialisation process and takes over the new Baud rate. The adapted Baud rate is displayed in Device Object in the Proprietary Property CALEC ST II 9
10 Änderungen vorbehalten / Sous réserve de modifications Modification rights reserved / Copyright INTEGRA METERING AG info@integra-metering.com * CALEC ST II
IF96014 BACnet COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement
25/07/14 Pagina 1 di 7 MULTIFUNCTION FIRMWARE 2.27 IF96014 BACnet COMMUNICATION PROTOCOL BACnet Protocol Implementation Conformance Statement Date: February, 17 th 2009 Vendor Name: IME Product Name: NEMO
More informationNemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:
30/03/12 Pagina 1 di 6 MULTIFUNCTION FIRMWARE 4.09 Nemo D4-L+ BACNET COMMUNICATION PROTOCOL BACnet Protocol Implementation Conformance Statement Date: March, 30 th 2012 Vendor Name: IME Product Name: NEMO
More informationBAS Integration Manual
Snow Melting Control 680 Introduction BAS Integration Manual Snow Melting 680_B 10/15 Replaces: 04/15 The Snow Melting Control 680 can communicate with a Building Automation System (BAS) using either BACnet
More informationElectronic pressure-independent characterised control valve with energy monitoring
Protocol Implementation Conformance Statement Energy Valve Electronic pressure-independent characterised control valve with energy monitoring Contents Protocol Implementation Conformance Statement - PICS
More informationSensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3
Sensor Sensor BACnet PICS 22DTH-..6.. Duct sensor humidity / temperature 22UTH-..60X Outdoor sensor humidity / temperature 22DTM-..6 Duct sensor CO2 / humidity / temperature Contents 1. Operating elements
More informationElectronic pressure-independent characterised control valve with energy monitoring
Protocol Implementation Conformance Statement Energy Valve Electronic pressure-independent characterised control valve with energy monitoring Contents Protocol Implementation Conformance Statement - PICS
More informationEPC3000 Programmable Controller
EPC3000 Programmable Controller Protocol Implementation Conformance Statement Date Vendor name Vendor ID Website Range name Product name 9 October, 2018 Schneider Electric 10 www.eurotherm.com EPC3000
More informationMulti-protocol heating and cooling energy calculator
CALEC ST ll Multi-protocol heating and cooling energy calculator Swiss Made Application The CALEC ST ll energy calculator can be used to create high-quality meters for heating, air conditioning, refrigeration
More informationChoose from our wide range of volume-measuring elements. Our advisers will be pleased to help you select the right ones for your needs.
For heating, air-conditioning, refrigeration or systems with thermal alternative energy VD 3-121e 02.2018 Application The CALEC ST II is used for energy metering in split systems which are equipped with
More informationBACnet Protocol Implementation Conformance Statement
BACnet Protocol Implementation Conformance Statement Date: 2012-06-27 Vendor Name: Trane Product Name: Trane TR150 Product Model Number: TR150 Applications Software Version: 3.0 Firmware Revision: 3.0
More informationUSB BACNET COMMUNICATION OPTION MANUAL
USB BACNET COMMUNICATION OPTION MANUAL SINGLE PHASE Series E, EM & IE EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500
More informationBelimo Gateway MP to BACnet MS/TP - UK24BAC
Product information UK24BAC BACnet MS/TP Belimo Gateway MP to BACnet MS/TP - UK24BAC Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
More informationBAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted
Product sheet MOD Type BAC-IO9 BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted BAC-IO9 and BAC-IO9-AI have been designed to be a compact wall mounted BACnet MS/TP input and output modules. The
More informationUSB BACNET COMMUNICATION OPTION MANUAL
USB BACNET COMMUNICATION OPTION MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610)
More informationCommunicative heating and cooling controller, BACnet MS/TP UB200. Summary
UB200 Communicative heating and cooling controller, BACnet MS/TP Summary UB200 is a communicative room heating controller with two inputs and two onoff/pwm outputs for control of a radiator or electrical
More informationBACnet Protocol Implementation Conformance Statement
BACnet Protocol Implementation Conformance Statement Date: October 06, 2009 Vendor Name: Schneider Electric Product Name: Low Voltage AC Motor Drive Product Model Number: Altivar 61 Application Software
More informationRF-RXS-B SonNet Wireless Receiver BACnet IP
Features & Benefits Sensing and controlling without the need of structural cabling Minimal downtime and costs for installation Seamless integration into BACnet IP over Ethernet DIN-rail mounted Easy to
More informationOutput AC L /DC + Power In AC C /DC - Btu ENERGY METER Model: 340 BN/MB S/N Power Out Signal - Sensor Input. Input LED.
Data Industrial 340 BN/MB Btu Energy Transmitter Hydronic Energy Transmitter with RS-485 BACnet and Modbus and Scaled Pulse Output AC L /DC + AC C /DC - Power Out Signal + Signal - Shield Sensor Input
More informationTR150 Embedded BACnet Operating Instructions
TR150 Embedded BACnet Operating Instructions BAS-SVX066A-EN January 2014 BAS-SVX066A-EN Contents Contents 1 Safety 2 2 Introduction 4 3 How to Install 6 3.1 The BACnet Interface 6 3.2 Bus Cabling 8 4 How
More informationBACnet communication module for TCX2: AEX-BAC
BACnet communication module for TCX2: AEX-BAC Features BACnet MS/TP communication over RS485 Slave type of communication Supports up to 127 nodes on one network Galvanic isolated bus connection Baudrates:
More informationSRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC
Product sheet CT2.143 Type SC-110-BAC SC-110 Series Zone Controllers with BACnet MS/TP The SC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue
More informationBACnet Integration Manual
BACnet Integration Manual With & Without Scheduling Controllers For Commercial HVAC Applications CONTENTS SE7600 Series Product Overview Protocol Implementation 2 Conformance Statements (PICS) 3 Device
More informationBACnet Option Module Instruction Manual
BACnet Option Module Instruction Manual TR200 November 2009 BAS-SVX24B-EN Table of Contents Safety 1-1 Copyright, limitation of liability and revision rights 1-1 High Voltage Warning 1-3 Before Commencing
More informationPIR Ready SE7200, SE7300 & SER7300 Series
PIR Ready SE7200, SE7300 & SER7300 Series 24 Vac Zoning, Fan Coil and Line-Voltage Fan Coil Controllers For Commercial and Lodging HVAC Applications CONTENTS Protocol Implementation Conformance Statement
More informationCALEC ST Innovative solutions in energy measurement
CALEC ST Innovative solutions in energy measurement Applications The CALEC ST is an energy totalizer with communication capabilities for critical measuring tasks such as those for: Heating plants Climatic
More informationOutput AC L /DC + Power In AC C /DC - Btu ENERGY METER Model: 340 BN/MB S/N Power Out Signal - Sensor Input. Shield. Input LED.
Data Industrial 340 BN/MB BTU Energy Transmitter Hydronic Energy Transmitter with RS-485 BACnet and Modbus and Scaled Pulse Output AC L /DC + AC C /DC - Power Out Signal + Signal - Shield Sensor Input
More informationMINI and MIX Series I/O modules
MINI and MIX Series I/O modules User Manual BACnet Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Contents 1 Introduction... 4 1.1 Revision history... 4 1.2 Safety rules... 6 1.3 Technical specifications...
More informationOperating Instructions
MAKING MODERN LIVING POSSIBLE Operating Instructions VLT DriveMotor FCP 106 and FCM 106 BACnet www.danfoss.com/drives Contents Contents 1 Introduction 3 1.1 Purpose of the Manual 3 1.2 Additional Resources
More informationDTS BACnet MSTP Map Version 3.2U TABLE OF CONTENTS
DTS BACnet MSTP Map Version 3.2U TABLE OF CONTENTS 1 SCOPE... 2 1.1 IDENTIFICATION... 2 1.2 INTRODUCTION... 2 2 BACNET INTERFACE SPECIFICATION... 3 2.1 GENERAL INFORMATION... 3 2.1.1 BACnet Object_Types
More informationBACnet communication module for TCX2: AEX-BAC
BACnet communication module for TCX2: AEX-BAC Features BACnet MS/TP communication over RS485 B-ASC Device Profile Slave type of communication Supports up to 128 nodes on one network Galvanic isolated bus
More informationSKDESC-xB Series Electronic Steam Controller
Electronic Steam Controller BACnet Communication Module User Guide SKDESCXB-BACnet-131114-EUA.docx Table of Contents Introduction & BACnet Requirements... 4 Introduction... 4 BACnet Requirements... 4
More informationGE Consumer & Industrial Electrical Distribution. AF-600 FP TM BACnet. Operating Instructions
GE Consumer & Industrial Electrical Distribution AF-600 FP TM BACnet Operating Instructions Contents 1 Introduction 3 Introduction 3 2 Safety 7 Copyright, Limitation of Liability and Revision Rights 7
More informationSupercal 531 Multi function Integrator that lives up to Your highest expectations
n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces
More informationECB-103 BACnet B-ASC 10-Point Programmable Controllers
D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,
More informationSAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.
Thank you for purchasing MD100P BACnet ption Board. SAFETY PRECAUTINS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety precautions are classified into
More informationMPS PROFIBUS-DP INTERFACE
3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/protectionrelays MPS PROFIBUS-DP INTERFACE PRELIMINARY SEPTEMBER 8, 2003 Publication: PROFIBUS-M
More informationPIR Ready VT72xx & VT(R) 73xx Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications
PIR Ready VT72xx & VT(R) 73xx Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications BACnet Integration Manual ITG-VT(R) 72_73-BAC-E11 (028-6009 R11 Issue Date: February
More informationN30P DIGITAL PANEL METER
N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,
More informationIntroduction to BAS Technology
Introduction to BAS Technology Dave Kahn, P.E. Why Back to basics? Sometimes you get what you ask for resulting in: The perfect job OR Unhappy owners & occupants Unexpected network limitations Product
More informationCommunication. Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus. Technical, Installation and Configuration Information
Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus Document Applicable to: Versatronik 532 Solar/Modbus P/N 704089 Versatronik 532D Solar/Modbus P/N 704090 Communication Applicable
More informationEVCB14NIT4X. BACnet Communication Module User Guide
(4 TRIACS / pressure independent / external motor) EVCB14NIT4X-V500-BACnet Guide-EUA-180927 Contents EVCB14NIT4X Introduction... 1 Pre-requisites... 1 Advantages of BACnet... 1 BACnet Properties Configuration...
More informationType EM-IP BACNET/IP INTERFACE, MODBUS/IP INTERFACE, AND WEBSERVER FOR EASYLAB CONTROLLERS AND TAM ADAPTER MODULES
Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Expansion modules > Type EM-IP Type EM-IP BACNET/IP INTERFACE, MODBUS/IP INTERFACE, AND WEBSERVER FOR EASYLAB CONTROLLERS AND
More informationULTRASONIC D. Compact ultrasonic heat meter
ULTRASONIC D Compact ultrasonic heat meter Applications ULTRASONIC D is a compact ultrasonic heat meter used for measuring energy in heating and cooling plants in facility management systems as well as
More informationBACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665
BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665 Application Note 140-1113 Building Technologies Table of Contents Overview... 5 BACnet...
More informationUser Guide. EVCB14NIT4X-V410-BACnet Guide-EUA docx
(4 TRIACS / pressure independent / external motor) BACnet Communication Module User Guide EVCB14NIT4X-V410-BACnet Guide-EUA-170524.docx Contents EVCB14NIT4X Introduction... 1 Pre requisites... 1 Advantages
More informationMetasys Integrator ESAM E as VND device Application
Systems Integration Services Europe Application Note Issue Date 0203 APPLICATION NOTE Metasys Integrator ESAM E742002 as VND device Application Introduction 2 Systems Integration Services Europe Contacts
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationKATflow 230 Portable Clamp-On Ultrasonic Flowmeter
Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative
More informationInstallation & Operation Manual
Badger Series 340N2 METASYS Compatible Energy Transmitter Installation & Operation Manual BadgerMeter, Inc. 872033 Rev. 6 4-09 Introduction The Badger Meter Series 340N2 Btu transmitter is an economical,
More informationMicroprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515
Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515 Technical Information 03/2012 FLOW THE EXPERT IN LEVEL AND FLOW DigiFlow
More informationExcel 800 / Excel Web II CABLE SPECIFICATIONS
HONEYWELL EXCEL 5000 OPEN SYSTEM Excel 800 / Excel Web II CABLE SPECIFICATIONS PRODUCT INFORMATION U.S. Registered Trademark Copyright 2014 Honeywell Inc. All Rights Reserved EN0B-0689GE51 R0114 Excel
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet 1 PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationOperating manual for the electronic transmitter UMC3-FF with Foundation-Fieldbus interface
Operating manual for the electronic transmitter UMC3-FF with Foundation-Fieldbus interface Supplement to the TM/UMC3, TMU/UMC3, TMR/UMC3 and TME/UMC3 Heinrichs Messtechnik GmbH Robert-Perthel-Str. 9 D
More informationModbus communication module for TCX2: AEX-MOD
Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation
More informationAcuMesh Wireless RS485 Network. User's Manual SOLUTION
AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the
More informationTip 65: Position control with MICROMASTER420 frequency converter
Seite 1 von 13 Version 5.1. Updated 8/02 Position control with MICROMASTER420 frequency converter and asynchronous motors with USS protocol (Tip 65) Category: Motor Control Special Hardware Requirements:
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet 1 PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationFCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE
FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE BACnet Enabled Description The FCU-503 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationEnergy Management Energy Meter Type EM340
Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order
More informationDEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description
Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationP/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123
TECHNICAL DATASHEET #TDAX181000 TC/Analog Inputs to CAN Controller 4 Thermocouple, 7 Analog & 3 Signal Inputs 12 Vdc, 24 Vdc, 48 Vdc 2 CAN (SAE J1939) with Electronic Assistant Description: The TC/Analog
More informationBACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682
BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682 Application Note 140-1156 Building Technologies Table of contents Overview... 5 BACnet...
More informationSolarEdge Feed-in Limitation Application Note
SolarEdge Feed-in Limitation Application Note Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a
More informationEnergy Management Energy Meter Type EM111
Energy Management Energy Meter Type EM111 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter
More informationEnergy Management Energy Meter Type EM112
Energy Management Energy Meter Type EM112 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter
More informationSales and Engineering Data Sheet ED
Sales and Engineering Data Sheet ED 15103-6 Group: Controls Part umber: ED 15103 Date: July 2018 MicroTech III Water Source Heat Pump Unit Controller Protocol Information LonWorks etworks BACnet etworks
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationAG FB-CAN. Absolute encoder viva CAN. Product Manual E-V0204.doc
AG FB-CAN Absolute encoder viva CAN Product Manual 04-02-03-E-V0204.doc Further descriptions, that relate to this document: UL: 07-02-08-01 631- Product - manual UL: 07-01-05-06 635- Product - manual UL:
More informationUN2 - Universal controller Building automation s missing link
Building automation s missing link Introduction A flexible line of controllers that allows facility managers, contrac - tors and OEM manufacturers to deploy integrated solutions for HVAC, lighting, and
More informationSUPPLY NETWORK ANALYZER CVM-96 SERIES
SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY
More informationInstallation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems
Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509
More informationHEAT CALCULATOR MODEL 212
HEAT CALCULATOR MODEL 212 July 1998 CONTENTS 1. Overview 3 1.1 Model Number Designation 5 1.2 Conversion Factors 6 2. Specification 7 3. Operation 11 3.1 Display Operation 13 3.1.1 Normal Operation 13
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative
More informationE8950 NOTICE WARNING. Modbus-to-BACnet Protocol Converter INSTALLATION GUIDE SPECIFICATIONS PRODUCT IDENTIFICATION PRODUCT OVERVIEW
o. NETWORK INTEGRATION C f N o r TUV Rheinland t h A m e r i c a, I n c E8950 -to-bacnet Protocol Converter US NOTICE This product is not intended for life or safety applications. Do not install this product
More informationA Super trainer with advanced hardware and software features only found in very expensive equipment.
PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such
More informationShenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/
ATC A-1 Serial Remote I/O Module User Manual V1.13 Edit:2018/01/30-1 - Catalogue 1.The introduction of Modbus protocol...- 3-1.1 Modbus protocol master-slave response process... - 3-1.2 Modbus register
More informationDin-Mon Smart Meter. Advanced kwh/demand Meters with Communication INSTALLATION INSTRUCTIONS
Din-Mon Smart Meter Advanced kwh/demand Meters with Communication INSTALLATION INSTRUCTIONS E-Mon 1985 Douglas Drive North Golden Valley, MN 55422 (800) 334-3666 www.emon.com info@emon.com 62-0442-05 Dear
More informationTOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z
TOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of BACnet Option unit. 2. Read this manual before installing
More informationRAY COMPACT ENERGY METER MECHANICAL
APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating
More informationBulletin B1243: RIBTW24B-BCAI RIBMNW24B-BCAI
Bulletin B243: RIBTW24B-BC RIBMNW24B-BC Enclosed BACnet Network Relay Device RIBTW24B-BC RIBMNW24B-BC One Binary Output (2 Amp Relay SPDT + Override) Contact Ratings: 2 Amp Resistive @ 277 Vac 2 Amp Magnetic
More informationMonitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55
Overview Application The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium,
More informationServoPac-A TTA-PRO Positioner
Application note April 1st, 2010 ServoPac-A TTA-PRO Positioner Hiperface/Endat absolute encoder feedback 1) INTRODUCTION This application note is dedicated to the commissioning of ServoPac-A range drives
More informationMicronics U1000MKII-HM
U1000MKII-HM Clamp On Ultrasonic Heat Meter User Manual Ltd, Knaves Beech Business Centre, Davies Way, Loudwater, High Wycombe, Bucks HP10 9QR Telephone: +44(0)1628 810456 E-mail: sales@micronicsltd.co.uk
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More informationDigital Multifunction Meter - RISH Integra 2000
Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement
More informationEIG DNP V3.0 Protocol Assignments
E Electro Industries/G augetech "The Leader in Web Accessed Power Monitoring" EIG DNP V3.0 Protocol Assignments For Futura+ and DM Series Power Monitors Version 1.14 July 15, 2003 Doc # E100-7-03 V1.14
More informationIBM Platform Technology Symposium
IBM Platform Technology Symposium Rochester, Minnesota USA September 14-15, 2004 Remote control by CAN bus (Controller Area Network) including active load sharing for scalable power supply systems Authors:
More informationEnergy Management Energy Analyzer Type EM112
Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement
More informationRAY MC COMPACT ENERGY METER MECHANICAL
APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing
More informationAHRI Standard Standard for Performance Rating of Modulating Positive Displacement Refrigerant Compressors
AHRI Standard 545 2017 Standard for Performance Rating of Modulating Positive Displacement Refrigerant Compressors IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify
More informationCCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault
CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...
More informationGas Fired Humidifier SKG Series
Gas Fired Humidifier SKG Series BACnet Communication Module User Guide SKG-BACNET Rev.: 060803 Table of content Table of content...1 Introduction & BACnet Requirements...2 Introduction...2 BACnet Requirements...2
More information