DTR n n n n n. Notice de fonctionnement User s manual Bedienungsanleitung Libretto d istruzioni Manual de instrucciones 3

Size: px
Start display at page:

Download "DTR n n n n n. Notice de fonctionnement User s manual Bedienungsanleitung Libretto d istruzioni Manual de instrucciones 3"

Transcription

1 n n n n n RATIOMÈTRE RATIOMETER RATIOMETER RAPPORTOMETRO RATIOMETER DTR 8500 FRANÇAIS ENGLISH DEUTSCH ITALIANO ESPANOL Notice de fonctionnement User s manual Bedienungsanleitung Libretto d istruzioni Manual de instrucciones 3

2 Meaning of the symbol : Warning! Please refer to the User s Manual before using the instrument. In this User s Manual, the instructions preceded by the above symbol, should they not be carried out as shown, can result in a physical accident or damage the instrument and the installations. Thank you for purchasing a Ratiometer DTR To get the best service from this instrument: - read this user s manual carefully, - respect the safety precautions detailed. SAFETY PRECAUTIONS n The Digital Transformer Ratiometer DTR 8500 is designed for use on de-energised («deactivated») transformers only. Make sure that the device tested has been completely disconnected from the mains power supply and that it is fully discharged, before connecting the test leads. n Only qualified staff should use the instrument. The user is entirely responsible for his own safety. n Proceed with due care when working near transformers: high voltage and current may be present and constitute a danger of electrocution. n In the event of an electric shock, the ratiometer (especially its leads) does not provide sufficient protection/insulation against high voltages. n Do not touch, adjust or reposition test cables when the DTR 8500 is conducting a test. n Never open the instrument when connected to the mains power supply or when test leads are connected to transformers, equipment, circuits, etc. n Always check the instrument and test cables before use. Faulty parts should be replaced immediately with genuine spare parts only (see 9. Maintenance). n Always use the correct fuse rating and type: failure to do so may result in damage to the instrument, causing the warranty to be null and vold (see 9. Maintenance). n This instrument has been designed for use indoors in an environment with the following characteristics: degree of pollution 2, altitude < 2000 m, temperature between 0 and 50 C and relative humidity of 0 to 90 %. n It can be used in category III installations, for voltages never exceeding 300 V with respect to the earth. Category III meets stringent reliability and availability crtiteria, corresponding to permanent use on industrial installations (see IEC 664-1). 21

3 CONTENTS 1. Presentation Description Technical specifications Measurements and operation Mode selection Voltage transformers (VT/PT) Current transformers (CT) Displayed messages Power supply (230V / 115V) Tips on obtaining accurate ratio measerements Appendix Warranty Maintenance Accessories and spare parts (to order)

4 1. PRESENTATION The DTR 8500 is a portable, sturdy and lightweight digital transformer ratiometer, designed for onsite testing of power, voltage and current transformers. Operation of the DTR 8500 is fully automatic. Calibration, range selection, hand-start or tedious adjustment is unnecessary. During each test cycle, the DTR automatically checks: n H/X lead reversal, n continuity of circuits/windings tested, n short-circuit conditions (high current). Upon completion of a test cycle, the DTR 8500 displays: n The transformation ratio the ratio of the primary to the secondary voltage at the transformer terminals resulting from the test. n Test current test current in RMS in the H winding resulting from the test during negligible loading of the associated X winding. n Polarity Indicates the polarity (phase) of X in relation to H. The transformation ratio, test current and polarity are useful parameters for diagnosing and predicting various faults that may occur in power, voltage and current transformers. The DTR 8500 displays the following messages: n Incorrect lead connections n H/X reversal (incorrect primary and secondary circuit connection, causing voltage set-up) n Short-circuit (excess test current) n Open circuits n Circuit continuity n Low battery The DTR 8500 uses an advanced, low-voltage step-down measurement technique in which the high voltage winding «H» is subjected to the test. Operator safety is thus improved and a larger range of types and sizes of transformer can be tested. 23

5 2. DESCRIPTION 2.1 Instrument 3 4 « V 50 Hz Top side cable connector «H» (primary) 2. Bottom side cable connector «X» (secondary) 3. Display 4. Battery charge indicator 5. Mains input 6. Fuse tray 7. Power supply adjustment (label) 8. Adjustment of display contrast 9.TEST button 10. Off/on switch 2.2 Cables 24

6 3. TECHNICAL SPECIFICATIONS 3.1. Electrical Characteristics n Ratio range: Autoranging: to :1 n Accuracy: Ratio 1000:1 : ± 0.1 % of reading Ratio > 1000:1 : ± 0.2 % of reading NB : 23 C ± 5 C, 50 to 70% HR, full battery charge, no external fields. n Test signal : Mode PT/VT : 44 Vrms maximum Mode CT : 0-1A automatic level, Vrms n Test current display: Range: ma Accuracy: 2 % reading ± 2 ma n Test frequency: 70 Hz n Display: LCD, 20 x 2, adjustable backlighting, visible day/night n Measurement method: In accordance with ANSI/IEEE C n Power supply: NiCd rechargeable battery and 230/115 V (50/60 Hz) mains supply. Unit can be changed from 230 V to 115 V by an internal switch. Units supplied pre-set to 230 V are available. n Battery: NiCd 12.5 V x 2, 1300 ma/h, Panasonic P-130SCR or equivalent n Battery life: Up to 10 hrs continuous operation. The DTR can be used while recharging. Low battery is indicated on the LCD. n Charging time: Approximately 14 hrs n Fuses: 1.0 A V (5x 20 mm), slow-acting 0.5 A V (5 x 20 mm), slow-acting 4 A V (5 x 20 mm), slow-acting 3.2. General characteristics n Safety: IEC , Cat III, 300 V, degree of pollution 2 n EMC: EN /EN n Connections: Cannon XLR connectors and large industrial colour-coded clips n Leads: 5 m, H and Y colour-coded, in a shoulder bag n Display: 99 x 24 mm alphanumeric, adjustable contrast and backlighting n Operation temperature: 0 to 50 C, 0 to 90% RH (without condensation) n Storage temperature: - 20 C to 70 C n Unit: High-resistance yellow polypropylene (yellow) n Dimensions: 330 x 305 x 152 mm n Weight: 6.4 kg 25

7 4. MEASUREMENT AND OPERATION The Digital Transformer Ratiometer DTR 8500 is designed for use on non-energised transformers only. Make sure that the device tested has been disconnected from the mains power supply and that it is fully discharged. To conduct a test: 1. Connect the DTR test cables correctly to a non-energised transformer. See examples of connection et Switch the DTR on and select the appropriate test mode. (See below for mode selection 4.1). 3. When the Ready message appears, press the test button to start. After a short test cycle, the ratio, polarity and test current will be displayed. NB : Please refer to the VT/PT and CT Test of this manual for complete operating information Mode selection The operating mode of the DTR is configured when the instrument is powered up. The default test mode is VT/PT. To enter the CT test mode, press on the TEST button while switching the machine on and hold down until «CT Test Mode Selected» is displayed. n Use VT/PT test mode for testing voltage transformers (maximum test voltage of 44 V). n Use CT test mode for testing current transformers (maximum test current of 5 V). n The DTR automatically reverts to the VT/PT test mode when the power is switched off. 26

8 4.2. Voltage transformers (VT/PT) Examples of VT/PT connections Here is an example of connections to an ordinary 7200: 120/240 distribution transformer with a centre-tapped secondary winding. NB : n Unlike other instruments, the DTR 8500 does not impose polarity restrictions or forced autoconnections; thus there are several valid connections and virtually all transformer configurations can be tested. n In all tests, a minus sign before the ratio displayed indicates phase reversal (inverted polarity) of the X signal detected in relation to the test signal at H. When using the DTR, always make a note of the colour code of the test cable clamps. 27

9 VT/PT Tests 1. When the instrument is set up for a VT/PT test, the DTR displays the message «VT/PT Test Mode Ready» after the initial power-up sequence. This message indicates that the DTR is now ready to execute a test. 2. Press the TEST button once. The test must not be performed when staff are handling transformer connections. 3. «Press TEST to Check Continuity» is now displayed for three (3) seconds. If you wish to do a continuity test, press the TEST button once. The results of the continuity test are displayed as CONT or OPEN for the X and H connections. Refer to the VT/ PT continuity test ( 4.25) for more information. 4. The next message to be displayed is *Ratio Testing TEST to Cancel». The asterisk (*) will flash while testing lasts. You can cancel the test at this stage by pressing the TEST button once. If the test continues, the ratio and test current will be displayed. 5. Once the results of the test are recorded, press the TEST button to reset for the following test. NB: This sequence can be repeated as often as required without disconnecting the unit. 28

10 4.2.3 VT/PT test mode flow chart Display indication for VT/PT mode Version XXX 1997 Chauvin Arnoux Operator action Switch unit on Comments Indicates version of internal firmware AEMC Instruments DTR* Model 8500 N/A Identification of the model AEMC Instruments Low Battery N/A Replaces above indication when battery needs recharging VT/PT Test Mode N/A Indication of selected mode Calibrating Please Wait VT/PT Test Mode Ready N/A Now press on TEST to initiate test Internal calibration in process System ready to begin test Press TEST to Check Continuity Ratio Testing Test to Cancel Now press TEST to verify continuity or do nothing to skip Now press TEST to cancel test in process Continuity test Option selected Ratio test in process with test cancel option Ratio: : 1 Current: 11 ma Now press TEST to reset for the next test 29

11 4.2.4 VT/PT test current Test current, displayed in milliamperes is the RMS current in the H winding due to the test, during negligible loading of the associated X winding. The DTR uses a maximum test signal of 44 V for testing; the test current value displayed will almost always be a small fraction of the no-load excitation of the transformer tested at full rate voltage. The majority of transformers require 100 ma or less; some require less than 1 ma. Note: If you are currently using a ratiometer with X side step-up excitation (for example, a manually-operated instrument), the test current displayed by the DTR will be significantly lower in the majority of cases. This is normal and is due to the fact that in most step-down type transformers, the H winding shows a much higher impedance than the associated X winding VT/PT continuity test The DTR 8500 continuity test function is used to identify open primary and secondary windings, open circuit-breakers and blown fuses. When the function is selected, the DTR alternately verifies continuity between the X and H cables. The continuity test is selected when the user presses TEST at the Press TEST to Check Continuity prompt. The DTR displays the results of the continuity test then enters a brief demagnetising period. In the meantime, the Pre-Test Checks message is displayed. n The DTR indicates OPEN for tested circuits greater than 2 kw and CONT for those less than 2 kw. A small percentage of transformers (for example, those with high inductance or winding resistance) can be considered as open circuits by the DTR. n If OPEN is indicated, this does not cancel out the test cycle in process and the results of the ratio test will continue to be displayed. n Transformers with winding arrangements involving several parallel paths (for example, delta connected types) may display CONT, when, in fact, one or several windings are open. 30

12 4.3 Current transformers (CT) Examples of CT connections Current transformer ratio testing (CT) is performed by connecting the H cable set to the X winding and by short-circuiting the X cable set through the CT aperture as described below. This creates a step-down type set up in which the X winding serves as the primary circuit and the X set of cables as a one-turn secondary winding CT tests 1. When the instrument is set for a CT test; the DTR displays the message «CT Test Mode Selected» after the initial power-up sequence. This message indicates that the DTR is now ready to execute a test. 2. Press the TEST button once to begin the test cycle. 3. The next message displayed is «*Ratio Testing TEST to Cancel». The asterisk (*) flashes while testing lasts. You can cancel the test at this stage by pressing the TEST button once. If the test continues, the ratio and test current will be displayed. 4. Once the results of the test are recorded, press the TEST button to reset for the following test. NB: Comes pre-set to 230 V the DTR may not be able to provide the correct ratio for some low mass, low ratio current transformers. The message «High Excitation Current» is displayed. As in VT/PT test mode, the sequence can be repeated as often as required without disconnecting the unit. CT test mode remains active until the power supply is switched off. 31

13 4.3.3 CT test flow chart Display indication for CT mode Operator action Comments Version XXX 1997 Chauvin Arnoux Switch unit on holding down TEST button Indicates version of internal firmware AEMC Instruments DTR* Model 8500 Hold TEST button down Identification of the model AEMC Instruments Low Battery Hold TEST button down Replaces above indication when battery needs recharging CT Test Mode Release TEST button Indication of selected mode Calibrating Please Wait CT Test Mode Ready N/A Now press on TEST to initiate test Internal calibration in process System ready to begin test Ratio Testing Test to Cancel Ratio: : 1 Current: 35 ma Now press on TEST to cancel test in process Now press on TEST to reset for the next test Ratio test in process with test cancel option 32

14 4.4 Displayed messages Check for H <> X Cable Reversal The DTR may have detected a potentially dangerous voltage step-up while trying to test the transformer as connected. Verify the connections: HRED and HBLACK should be attached to the high voltage winding. XRED & XBLACK should be attached to the low voltage winding. High Excitation Current Verify test cable connections to check for inadvertent short-circuits. Check there are no shortcircuited transformer windings. Check Cables & Connectors Verify that all test cable connections have been made correctly and are firmly attached to transformer terminals. Verify the transformer terminal for dielectric coating, fungus and corrosion. Low Battery Indicates the battery is low. Recharge the battery immediately. Note: The DTR can operate while battery is being recharged. Calibrating Please Wait The DTR always self-calibrates when powered up. The DTR will also automatically selfcalibrate:. at periodic intervals,. after 32 test cycles in a row,. after detection of an error causing the DTR to automatically cancel the test in progress. VT/PT Test Mode Operating mode used for a VT/PT test, default mode when powered up. VT/PT Test Mode Ready Indicates the system is ready for the VT/PT test. CT Test Mode Selected Indicates selection by the user of the CT test mode. This mode is selected by pressing down the TEST button and holding it down during the power-up sequence. CT Test Mode Ready Indicates the system is ready for the CT test. X Circuit: OPEN (or CONT) See the VT/PT continuity test section H Circuit: OPEN (or CONT) See the VT/PT continuity test section Low X Signal Check X cables for inadvertent short-circuits. The X winding may be short-circuited or the transformer circuit-breaker may be open. Low H Signal Check H cables for inadvertent short-circuits. Check H cable connector on the DTR front panel. 33

15 5. POWER SUPPLY The DTR 8500 can be used for a maximum of 10 hours with fully-charged NiCd batteries. The DTR can also be powered from the mains supply during measurement. In this mode, the DTR also recharges the NiCd batteries. LOW BATTERY is displayed when the internal batteries are low. When this signal is displayed, a limited number of measurements can still be executed, although we recommend recharging the DTR as soon as possible. If battery voltage drops too low, the DTR will block further operations. In blocked mode, the DTR interrupts all functions until the mains supply is restored and the battery recharged. We recommend recharging the DTR at night. Each time the DTR is connected to the mains, a 14-hour recharge cycle begins. Repeated charging of partially discharged batteries will not damage the battery. During the 14-hour cycle, the CHARGING indicator will remain lit; after this period, a pulse maintenance charge mode is instituted and the indicator flashes. NB: The ratiometer comes pre-set to 230 V. 34

16 Changing power setting between 230 V and 115 V The power supply setting of the instrument can be switched between 230 and 115 volts by following the procedure below: 1. Switch the power off. Disconnect the instrument from all inputs and power. 2. Unscrew the four bottom screws. 3. Remove the instrument from the unit. 4. Locate the switch next to the transformer (see drawing). 5. Set the red switch to 115 V or 230 V. The switch setting indicates the selected voltage. 6. Replace the fuse (see power input) with the appropriate current rating. 115 V = 1 A, 230 V = 0.5 A 7. Carefully replace the instrument in the unit and fasten the bottom screws. 8. Remove the old voltage label. Place the input voltage label (115 V or 230 V) beneath the mains power supply input. 35

17 6. TIPS ON OBTAINING ACCURATE RATIO MEASUREMENTS n Always verify the integrity of test cable connections and reposition test clips if necessary. Check the transformer terminals for dielectric coatings, fungus and corrosion. n During VT/PT mode operation, select «Continuity Test» whenever possible. Apart from being a useful way of checking windings and connections, this test has the advantage of reducing the magnetic afterglow in the transformer being tested. This is particularly important in transformers with series resistance or low kva transformers with extremely high primary side inductance. This is not necessary for most tap-change and regulator transformers. n When testing polyphase transformers, bear in mind that, in some cases, the ratios measured should be multiplied or divided by Ö3. Refer to Attachment 7. for polyphase connection diagrams and associated ratio equations. 1/1 Ratio test A simple test can be conducted to test the functionality of the DTR. By connecting HRED to XRED and (separately) HBLACK to XBLACK, you simulate a 1/1 transformer. Operation of the DTR in this configuration should give a ratio very nearly equal to If this is not the case, the DTR should be repaired or calibrated. 36

18 7. APPENDIX Polyphased connections Ref. N TRANSFORMER - XFMR TYPE PHASE HIGH HIGH VOLTAGE WINDING LOW VOLTAGE WINDING 1Ø STD D - D STD D - D REV D - Y STD D - Y REV Y- Y STD Y- Y REV Y - D STD Y - D REV 1 Ø H 1 - H 2 X 1 - X 2 V H V X A B C A B C A B C A B C A B C A B C A B C A B C VOLTAGE WINDING H 1 - H 3 (A) H 2 - H 1 (B) H 3 - H 2 (C) H 1 - H 3 (A) H 2 - H 1 (B) H 3 - H 2 (C) H 1 - H 3 (A) H 2 - H 1 (B) H 3 - H 2 (C) H 1 - H 3 (A) H 2 - H 1 (B) H 3 - H 2 (C) H 1 (A) H 2 (B) H 3 (C) H 1 (A) H 2 (B) H 3 (C) H 1 (A) H 2 (B) H 3 (C) H 1 (A) H 2 (B) H 3 (C) LOW VOLTAGE WINDING X 1 - X 3 (a) X 2 - X 1 (b) X 3 - X 2 (c) X 1 - X 3 (a) X 2 - X 1 (b) X 3 - X 2 (c) X 1 (a) X 2 (b) X 3 (c) X 1 (a) X 2 (b) X 3 (c) X 1 (a) X 2 (b) X 3 (c) X 1 (a) X 2 (b) X 3 (c) X 1 - X 2 (a) X 2 - X 3 (b) X 3 - X 1 (c) X 1 - X 2 (a) X 2 - X 3 (b) X 3 - X 1 (c) TRANSFOR- MATION RATIO V H V X V H V X V H x Ö3 V X V H x Ö3 V X V H V X V H V X V H V X x Ö3 V H V X x Ö3 37

19 8. WARRANTY Our guarantee is applicable for twelve months after the date on which the equipment is made available (extract from our General Conditions of Sale, available on request). 9. MAINTENANCE For maintenance, use only specified spare parts. The manufacturer will not be held responsible for any accident occurring following a repair done other than by its After Sales Service or approved repairers Replacing the fuses For your safety the leads mus be deconnected from the DTR before the cover is opened. n Open the cover. n Replace the faulty fuses respecting their value and their type : See To order. n Refit the cover before using the ratiometer Cleaning n Keep the jaw faces perfectly clean. Remove dust with a soft dry cloth. Now and then, clean the jaw faces with a lightly oiled solft cloth. n Clean the case with a cloth slightly moistened with soapy water. Rinse with a dry cloth. Then dry quickly with a cloth or in a hot air stream (80 C max.) Calibration As any other measuring or test instrument, your instrument must be regularly checked. For checking and calibration of your instrument, please contact our accredited laboratories (list on request) or the Chauvin Arnoux subsidiary or Agent in your country. Repairs under or out of guarantee: please return the product to your distributor. 38

20 10. TO ORDER DTR 8500 Ratiometer.... P Comes pre-set to 230 V, with a type power lead and two test leads (5 m marked «H» and «X») in a shoulder bag and operating instructions. Accessory n Set of 2 test leads (10 m - «H» and «X»)... P Spares n Set of 2 test leads (5 m - «H» and «X»)... P n NiCd 12 V 1.3 A/h battery... P n Set of 5 x 4 A V (5 x 20 mm) slow-acting fuses... P n Set of 5 x 0.5 A V (5 x 20 mm) slow acting fuses... P n Set of 10 x 1A V (5 x 20 mm) slow-acting fuses.... P

F 03. Pince multimètre Clamp multimeter Vielfachmesszange Pinza multimetro Pinza multimetrica

F 03. Pince multimètre Clamp multimeter Vielfachmesszange Pinza multimetro Pinza multimetrica Pince multimètre Clamp multimeter Vielfachmesszange Pinza multimetro Pinza multimetrica F 03 FRANÇAIS E N G L I S H D E U T S C H ITALIANO E S P A N O L Notice de fonctionnement User's manual Bedienungsanleitung

More information

C.A 6521 C.A 6523 C.A 6525

C.A 6521 C.A 6523 C.A 6525 MEGOHMMETRES MEGOHMMETERS MEGOHMMETER MEGAOHMMETRI MEGAÓHMETRO C.A 6521 C.A 6523 C.A 6525 FRANÇAIS ENGLISH DEUTSCH ITALIANO ESPANOL Notice de fonctionnement User's manual Bedienungsanleitung Libretto d

More information

Sound Level Meter C.A 832

Sound Level Meter C.A 832 Sound Level Meter C.A 832 E N G L I S H User's manual 1 Meaning of the symbol Caution! Please refer to the user s manual before using the instrument. In this manual, the instructions preceded by the above

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II ON OL AC/DC CURRENT PROBE K1 K2 ON OL 300V CAT II 10 mv/ma OFF C H A U V IN A R N O U X K2 AC/DC CURRENT PROBE 1 mv/ma OFF C H A U V IN A R N O U X K1 AC/DC CURRENT CLAMP E N G L I S H User's manual 1

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS n 8505 QUICK TESTER FOR TRANSFORMERS AND CAPACITORS E N G L I S H User Manual Table of Contents 1. INTRODUCTION... 3 1.1 Receiving Your Shipment...3 1.2 Ordering Information...3 1.2.1 Replacement Parts...3

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

TRMS LEAKAGE CURRENT CLAMP-ON METER 565 TRMS LEAKAGE CURRENT CLAMP-ON METER 565 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards

More information

AC/DC Current Probes Model MR411 Model MR521

AC/DC Current Probes Model MR411 Model MR521 AC/DC Current Probes Model MR411 Model MR521 USER MANUAL OL OL ON ON 600V CAT III - 600A 600V CAT III - 1500A 60A 600A OFF 150A 1500A OFF! OUTPUT: 600A: 1 mv/a 60A: 10 mv/a! OUTPUT: 1500A: 1 mv/a 150A:

More information

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga Pinza Multímetro - Corrientes de fugas F 62 F 65 FRANÇAIS ENGLISH DEUTSCH

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL Table of Contents 1 SAFETY PRECAUTIONS Before use, read the following safety precautions.- 1-1 Explanation of Warning Symbols 001 1-2 Warning Messages for Safe

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

UT232. Operating Manual. Digital Power Clamp Meter

UT232. Operating Manual. Digital Power Clamp Meter UT232 Operating Manual Digital Power Clamp Meter Model UT232 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical

More information

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

MHz FUNCTION GENERATOR INSTRUCTION MANUAL 72-6859 20MHz FUNCTION GENERATOR INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 EMC 5 Safety 4 Installation 5 Operation 7 Maintenance 8 www.tenma.com 1 Introduction This instrument

More information

GFL-1000 User Manual Ground Fault Locator

GFL-1000 User Manual Ground Fault Locator GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...

More information

Model UT233 OPERATING MANUAL

Model UT233 OPERATING MANUAL Model UT233 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure A. The Meter Front

More information

CONTENTS MS2033A. 1.Introduction Safety Information...01

CONTENTS MS2033A. 1.Introduction Safety Information...01 MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2-

More information

Model : OPERATING MANUAL Table of Contents (1)

Model : OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

Générateur de Fonctions 5 MHz 5 MHz-Function Generator 5 MHz-Funktionsgenerator Generatore di Funzioni 5 MHz Generador de Funciones 5 MHz

Générateur de Fonctions 5 MHz 5 MHz-Function Generator 5 MHz-Funktionsgenerator Generatore di Funzioni 5 MHz Generador de Funciones 5 MHz Pôle Test et Mesure de CHAUVIN ARNOUX Parc des Glaisins - B. P. 330 6, avenue du Pré de Challes F - 74943 ANNECY-LE-VIEUX Cedex Tél. +33 (0)4.50.64.22.22 - Fax +33 (0)4.50.64.22.00 3240 Générateur de Fonctions

More information

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A AC/DC OSCILLOSCOPE CURRENT PROBES MR461 MR561 OL OL ON ON 600V CAT III - 600A 600V CAT III - 1500A 60A 600A OFF 150A 1500A OFF!! OUTPUT: 600A: 1 mv/a 60A: 10 mv/a AC/DC CURRENT PROBE Model MR 461 OUTPUT:

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no. 20 751 696 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail:

More information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...

More information

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF I N S T R U M E N T S FLEXIBLE AC CURRENT PROBE FlexProbe 24-3001 ON OL 1000V CAT III 300A 3000A OFF FlexProbe 24-3002 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC

More information

MEGOHMMETER. User Manual

MEGOHMMETER. User Manual MEGOHMMETER 11 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

Pince Multimètre. Multimeter Clamp. Multimeterzange. Pinza Multimetro. Pinza Multímetro MX 670 / 675 E N G L I S H. User s manual

Pince Multimètre. Multimeter Clamp. Multimeterzange. Pinza Multimetro. Pinza Multímetro MX 670 / 675 E N G L I S H. User s manual Pince Multimètre Multimeter Clamp Multimeterzange Pinza Multimetro Pinza Multímetro MX 670 / 675 E N G L I S H User s manual TABLE OF CONTENTS 1 GENERAL INSTRUCTIONS...21 1.1 UNPACKING PACKING...21 1.2

More information

User Manual Digital Multimeter

User Manual Digital Multimeter User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500

More information

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No. 20 750 190 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: metrel@metrel.si

More information

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL 2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions

More information

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes FLEXIBLE AC CURRENT SENSOR High Frequency Response for Oscilloscopes MiniFlex MF 300-6-2-10-HF MF 300-10-2-10-HF E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments

More information

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III HZ 115 Differential probe for oscilloscopes 1500 V input voltage max. 30 MHz bandwidth x 100 and x 1000 attenuation 50 db CMRR (1MHz) User-friendliness through a microcontroller Automatic Switch-off Beep

More information

600A Clamp Meters w/tightsight Display

600A Clamp Meters w/tightsight Display V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

POWER CLAMP-ON METER 405

POWER CLAMP-ON METER 405 POWER CLAMP-ON METER 405 ENGLISH User Manual 2 CONTENTS RECEIVING YOUR SHIPMENT... 8 ORDERING INFORMATION... 8 1 PRESENTATION... 9 1.1 THE ROTARY SWITCH... 10 1.2 THE FUNCTION BUTTONS... 11 1.3 THE DISPLAY...

More information

30XR-A Professional Digital Multimeter Users Manual

30XR-A Professional Digital Multimeter Users Manual Professional Digital Multimeter Users Manual 99 Washington Street Melrose, MA 076 Fax 78-665-0780 TestEquipmentDepot.com MADE IN TAIWAN PATENTS PENDING www.amprobe.com MIN 5 00 00 0 0 00m 00m 00 0M m M

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

CLAMP-ON METER 670. User Manual

CLAMP-ON METER 670. User Manual CLAMP-ON METER 670 675 E N G L I S H User Manual Certificate of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual FLEXIBLE AC CURRENT SENSOR MiniFlex MF 300-6-2-10 MF 3000-10-2-1 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

312, 316, 318. Clamp Meter. Users Manual

312, 316, 318. Clamp Meter. Users Manual 312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-920 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2. Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1

More information

Pen-type DIGITAL MULTITESTER

Pen-type DIGITAL MULTITESTER BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...

More information

Multifunction Digital

Multifunction Digital MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

POWER CLAMP-ON METER. User Manual ENGLISH. 99 Washington Street Melrose, MA Phone Toll Free

POWER CLAMP-ON METER. User Manual ENGLISH. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 POWER CLAMP-ON METER Visit us at www.testequipmentdepot.com 205 ENGLISH User Manual Statement of Compliance Chauvin Arnoux,

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

C.A 6536 Megohmmeter

C.A 6536 Megohmmeter GB - User s manual C.A 6536 Megohmmeter Thank you for purchasing a megohmmeter C.A 6536. For best results from your instrument: read these operating instructions carefully, comply with the precautions

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

Instruction Manual for Digital Grounding Resistance Meter

Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4

More information

Digital Multimeter, Pen Type

Digital Multimeter, Pen Type MODEL: D03127 Digital Multimeter, Pen Type 1 CONTENTS Page Number Description 3 Important Safety Information 3 Electrical Symbols 4 Overview 4 Measurement Operation 5 AC & DC Voltage Measurement 5 AC &

More information

ATK Clamp Meter

ATK Clamp Meter ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...

More information

MI-10kV. Technical specifications Operating instructions. Supplier:

MI-10kV. Technical specifications Operating instructions. Supplier: Technical specifications Operating instructions Supplier: Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht P.O. Box 7023, 3502 KA Utrecht The Netherlands T +31 30 288 1311 F +31 30 289 8816 E sales@nieaf-smitt.nl

More information

Table of Contents Title Page

Table of Contents Title Page Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols

More information

1.General instructions Specifications Description...7

1.General instructions Specifications Description...7 USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.

More information

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n. MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10

More information

DIGITAL ANALOG MEGOHMMETERS

DIGITAL ANALOG MEGOHMMETERS DIGITAL ANALOG MEGOHMMETERS 1035 1039 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

SAFETY PRECAUTIONS: Before use, read the following safety precautions

SAFETY PRECAUTIONS: Before use, read the following safety precautions [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions This instruction manual explains how to use your multimeter CD731, CD751 safely. Before use, please read this manual thoroughly.

More information

Oberebenestrasse Bremgarten Switzerland Tel Fax

Oberebenestrasse Bremgarten Switzerland Tel Fax Oberebenestrasse 11 5620 Bremgarten Switzerland Tel. +41 56 640 06 70 Fax. +41 56 640 06 74 Single Phase - Battery Operated Automatic Transformer Turns Ratiometer Test System Model: TR-1 Model: TR-1P Instruction

More information

Model UT20B: OPERATING MANUAL Table of Contents (1)

Model UT20B: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Rotary Switch Display Symbols Measurement Operation A. AC Voltage

More information

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 2nd Edition IM E User s Manual 700937 Current Probe 2nd Edition Introduction Thank you for purchasing the 700937 Current Probe. This Instruction Manual contains useful information about the instrument s functions and operating

More information

I Pr I P I OUT R L. Applications. Standards

I Pr I P I OUT R L. Applications. Standards Ref: ATO-XXX-B225-D10 I Pr = 10, 15, 16, 20, 30, 32, 50, 60, 63, 75 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Megohmmeter Models 6526, 6532 and 6534

Megohmmeter Models 6526, 6532 and 6534 Megohmmeter Models 6526, 6532 and 6534 User Manual ENGLISH www.aemc.com Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced in any

More information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and

More information

MANUAL PCE-UT232

MANUAL PCE-UT232 www.pce-group-europe.com PCE- Deutschland Gmb H & Co. KG Tel: +49 029 03 976 99-0 Fax: +49 029 03 976 99-29 info@warensortiment.de www.warensortiment.de PCE Group Ibérica S.L. Tel: +34 967 543 548 Fax:

More information

G SAFETY WARNINGS. LT300 High current loop tester. User guide

G SAFETY WARNINGS. LT300 High current loop tester. User guide M LT300 High current loop tester User guide G SAFETY WARNINGS Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. The earth loop

More information

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL GENERAL INSTRUCTIONS This instrument complies with IEC 1010-1 (61010-1@IEC: 2001), CAT. II 1000V and CAT. III 600V overvoltage standards. See Specifications.

More information

DIGITAL MULTIMETER with Non-Contact Detection

DIGITAL MULTIMETER with Non-Contact Detection DIGITAL MULTIMETER with Non-Contact Detection 5233 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using

More information

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device

More information

DC/AC Current clamp 2000A A 1636 Instruction manual Version 1.2, Code no

DC/AC Current clamp 2000A A 1636 Instruction manual Version 1.2, Code no 2000A Instruction manual Version 1.2, Code no. 20 752 824 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: metrel@metrel.si 2012 METREL

More information