Ref /b VARMECA 10 Variable speed motors and geared motors. Parameter-setting manual

Size: px
Start display at page:

Download "Ref /b VARMECA 10 Variable speed motors and geared motors. Parameter-setting manual"

Transcription

1 en L This manual is to be given to the end user L L PE Parameter-setting manual

2 NOTE LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice. LEROY-SOMER gives no contractual guarantee whatsoever concerning the information published in this document and cannot be held responsible for any errors it may contain, nor for any damage resulting from its use. CAUTION For the user s own safety, this motor must be connected to an approved earth ( terminal). It is imperative that the equipment is supplied via an isolating device and a circuit-breaking device (power contactor) which can be controlled by an external safety system (emergency stop, fault detector). The motor is fitted with safety devices which, in the event of a fault, control stopping and thus stop the motor. The motor itself can become jammed for mechanical reasons. Voltage fluctuations, and in particular power cuts, may also cause the motor to stop. The removal of the causes of the shutdown can lead to restarting, which may be dangerous for certain machines or installations. In such cases, it is essential that the user takes appropriate precautions against the motor restarting after an unscheduled stop. is a component designed to be integrated in an installation or an electrical machine. It is the responsibility of the user to take all necessary precautions to ensure that the system complies with current standards. For safety reasons, LEROY-SOMER prohibits the use of for lifting applications. LEROY-SOMER declines all responsibility in the event of the above recommendations not being observed. 6

3 SAFETY AND OPERATING INSTRUCTIONS FOR ELECTRICAL ACTUATORS (In accordance with the low voltage directive //EEC modified by 9/6/EEC) Throughout the manual, this symbol warns of consequences which may arise from inappropriate use of the, since electrical risks may lead to material or physical damage as well as constituting a fire hazard. - General Depending on their degree of protection, motors may contain moving parts, as well as hot surfaces, during operation. Unjustified removal of protections, incorrect use, faulty installation or inappropriate operation could represent a serious risk to personnel, animals and equipment. For further information, consult the manual. All work relating to transportation, installation, commissioning and maintenance must be performed by experienced, qualified personnel (see IEC 64 or CENELEC HD 4, or DIN VDE 000 and national specifications for installation and accident prevention). In these basic safety instructions, qualified personnel means persons competent to install, mount, commission and operate the product and possessing the relevant qualifications. - Use motors are components designed for integration in installations or electrical machines. When integrated in a machine, commissioning must not take place until it has been verified that the machine conforms with directive 9/9/EEC (Machinery Directive). It is also necessary to comply with standard EN 6004, which stipulates in particular that electrical actuators (which include ) cannot be regarded as circuit-breaking devices and certainly not as isolating switches. Commissioning can take place only if the requirements of the Electromagnetic Compatibility Directive (9/6/EEC, modified by 9//EEC) are met. motors meet the requirements of the Low Voltage Directive //EEC, modified by 9/6/EEC. The harmonised standards of the DIN VDE 060 series in connection with standard VDE 0660, part 500 and EN 6046/ VDE 055 are also applicable. The technical characteristics and instructions concerning the connection conditions specified on the nameplate and in the documentation provided must be observed without fail. - Transportation, storage All instructions concerning transportation, storage and correct handling must be observed. The climatic conditions specified in the technical manual must be observed. 4 - Installation The installation and cooling of equipment must comply with the specifications in the manual supplied with the product. motors must be protected against excessive stress. In particular, there must be no damage to parts and/or modification of the clearance between components during transportation and handling. Avoid touching the electronic components and contact parts. motors contain parts which are sensitive to electrostatic stress and may be easily damaged if handled incorrectly. Electrical components must not be exposed to mechanical damage or destruction (risks to health!). 5 - Electrical connection When work is performed on motors which are powered up, national accident prevention specifications must be respected. The electrical installation must comply with the relevant specifications (for example conductor cross-sections, protection via fused circuit-breaker, connection of protective conductor). More detailed information is given in the manual. Instructions for an installation which meets the requirements for electromagnetic compatibility, such as screening, earthing, presence of filters and correct insertion of cables and conductors, are given in the documentation supplied with the. These instructions must be followed in all cases, even if the carries the CE mark. Adherence to the limits given in the EMC legislation is the responsibility of the manufacturer of the installation or the machine. 6 - Operation Installations incorporating motors must be fitted with additional protection and monitoring devices as laid down in the current relevant safety regulations : law on technical equipment, accident prevention regulations, etc. Modification of motors using control software is permitted. Active parts of the device and live power connections must not be touched immediately after the is powered down, as the capacitors may still be charged. In view of this, the warnings fixed to motors must be observed. During operation, all doors and protective devices must remain closed. - Servicing and maintenance Refer to the manufacturer s documentation. en

4 CONTENTS - GENERAL INFORMATION Operating principle General characteristics Weight and dimensions of the CDC-VMA console Wiring diagrams... - COMMISSIONING THE CDC-VMA CONSOLE Installation Presentation of the keypad Read mode Parameter-setting mode The parameters COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE Connection Installing the software Use The parameters TROUBLESHOOTING SUMMARY OF SETTINGS... 4 en 9

5 GENERAL INFORMATION - GENERAL INFORMATION. - Operating principle This manual describes access to the parameter settings of the (VMA ) range, using a CDC-VMA console or PEGASE VMA 0 PC software. Combined with the, these tools can simplify programming, diagnostics and displaying parameters.. - General characteristics.. - "CDC-VMA console" OPTION CONTENTS OF THE KIT: - power supply unit to connect to single phase mains supply 0 V - 50/60 Hz. - connection cable (length =.5 m) to connect to the. - console with digital LCD display - lines of 6 characters. - parameter-setting manual... - "PEGASE VMA 0 programming software" OPTION CONTENTS OF THE KIT: - connection cable (length = m) to connect to the, - disks for loading the software onto a PC (or CD-ROM). - parameter-setting manual. MINIMUM PC CONFIGURATION: - Pentium 00 MHz. - Mb of RAM. - WINDOWS 95 or Weight and dimensions of the CDC-VMA console See the following diagram CDC -VMA 5 P0 FMIN. FREQUENCE MIN. HZ MIN. FREQUENCY HZ MIN. FREQUENZ HZ P0 REF 4MA ETALONNAGE CONSIGNE MIN. HZ MIN. REF. SCALING HZ ABGLEICH SOLLWERT MIN. HZ P0 F MAX. FREQUENCE MAX. HZ MAX. FREQUENCY HZ MAX. FREQUENZ HZ P04 REF 0MA ETALONNAGE CONSIGNE MAX. HZ MAX. REF. SCALING HZ ABGLEICH SOLLWERT MAX. HZ P05 ACCEL. RAMPE ACCEL. S ACCEL. RAMP S HOCHLAUF RAMPE S P06 DECEL. RAMPE DECEL. S DECEL. RAMP S AUSLAUF RAMPE S P0 STOP MODE MODE D'ARRET STOPPING MODE HALTE MODUS 0 = ROUE LIBRE = RAMPE 0 = FREE WHEEL = RAMP 0 = FREILAUF = RAMPE P0 U / F LOI U / F U / F RATIO U / F KENNLINIE 0 = FIXE = DYNAMIQUE 0 = FIXED = DYNAMIC 0 = FEST = DYNAMISCH P BOOST BOOST % BOOST % BOOST % P F MOT. LECTURE FREQUENCE MOTEUR HZ MOTOR FREQUENCY STATUS HZ MOTOR FREQUENZ ANZEIGE HZ P4 I MOT. LECTURE COURANT MOTEUR A/0 MOTOR CURRENT STATUS A/0 MOTOR STROM ANZEIGE A/0 MEM. Weight : 0, kg 0

6 .4 - Wiring diagram GENERAL INFORMATION.4. - Standard configuration (factory setting) L + MAINS SUPPLY L L Local button or external potentiometer 0- speed image output PE 4 en 5 Ramp selection Fault relay Run reverse / stop Run forward / stop Terminals Specifications +0 V analogue source Rated current: ma Analogue reference input 0 to +0 V or 4-0 ma Analogue output 0 to +0 V Rated current: ma 0 V = zero speed 0 V = max. speed 4 0 V - common with terminal 6 Ramp selection logic input 5 s (50 Hz) = terminals 5 and 6 not connected s (50 Hz) = terminals 5 and 6 connected 6 0 V - common with terminal 4 Logic input run reverse/stop Logic input run forward/stop Relay output 50 V - A Associated parameter setting Reference K4 K Local button OFF - External potentiometer or ON ON external 0-0 V 4-0 ma reference ON OFF Setting other parameters see sections and 9-0 Switched off or faulty On

7 GENERAL INFORMATION.4. - Configuration option : preset speeds - operating directions L MAINS SUPPLY L L 0- speed image output PE 4 5 S Preset speed selection Fault relay Run reverse / stop Run forward / stop Terminals Specifications +0 V analogue source Rated current: ma Analogue input not used Analogue output 0 to +0 V Rated current: ma 0 V = zero speed 0 V = max. speed 4 0 V - common with terminal 6 5 Logic input S 6 0 V - common with terminal 4 Logic input run reverse/stop Logic input run forward/stop Relay output 50 V - A Associated parameter setting CDC-VMA PEGASE VMA 0 Terminal block configuration P4 = OPTION P5 = VP-(Hz) VP OPTION (Hz) P6 = VP-(Hz) VP OPTION (Hz) MINI DIP K4 = ON Reference S VP- VP Switched off or faulty On Setting other parameters see sections and

8 GENERAL INFORMATION.4. - Configuration option : analogue reference and preset speeds - operating direction MAINS SUPPLY L L L + External potentiometer or external reference 0- speed image output PE 4 5 S Preset speeds en Fault relay S Run/stop Preset speeds Terminals Specifications +0 V analogue source Rated current: ma Analogue input reference Analogue output 0 to +0 V Rated current: ma 0 V = zero speed 0 V = max. speed 4 0 V - common with terminal 6 5- Logic inputs S- S 6 0 V - common with terminal 4 Logic input run forward/stop Relay output 50 V - A Associated parameter setting CDC-VMA PEGASE VMA 0 Terminal block configuration P4 = OPTION P6 = VP-(Hz) VP OPTION (Hz) P = VP-(Hz) VP OPTION (Hz) P = VP-(Hz) VP OPTION (Hz) MINI DIP K4 = ON Reference Mini DIP K 0-0 V ON 4-0 ma OFF 9-0 Switched off or faulty On Reference S S VP- 0 VP- 0 VP- 0 0 Analogue reference Setting other parameters see sections and

9 GENERAL INFORMATION Configuration option : correction of an external reference with the speed control button - operating directions - enabling/disabling the control button Version with remote potentiometer Local button : adjustment from 0 to 00% of the external reference + 0KΩ MAINS SUPPLY L L L PE 4 5 S External reference 0- / 4-0mA Enable / disable local button 4 Fault relay Run reverse / stop Run forward / stop Terminals Specifications +0 V analogue source rated current: ma Analogue reference input 0 to +0 V or 4-0 ma Analogue output 0 to +0 V Rated current: ma 0 V = zero speed 0 V = max. speed 4 0 V - common with terminal 6 Logic input, for enabling/disabling the correction 5 S open = correction possible S closed = no correction 6 0 V - common with terminal 4 Logic input run reverse/stop Logic input run forward/stop Relay output 50 V - A Associated parameter setting CDC-VMA PEGASE VMA 0 Terminal block configuration P4 = OPTION MINI DIP K4 = ON Reference Mini DIP K 0-0 V ON 4-0 ma OFF Setting other parameters see sections and 9-0 Switched off or faulty On 4

10 GENERAL INFORMATION Configuration option 4: preset speeds fixed or proportional to the reference - operating direction MAINS SUPPLY Fault relay L L L PE S S + S External potentiometer or external reference Fixed or proportional preset speed selection Preset speed selection Run / stop Stopping mode en Terminals Specifications +0 V analogue source rated current: ma Analogue reference input Analogue input S 0 V - common with terminal 6 Logic input S 0 V - common with terminal 4 Logic input run/stop Logic input S Relay output 50 V - A Switched off or faulty On Associated parameter setting CDC-VMA PEGASE VMA 0 Terminal block configuration P4 = 4 OPTION 4 P5 = VP(Hz) VP OPTION -4(Hz) P6 = VP-(Hz) VP OPTION -4(Hz) MINI DIP K4 = ON Reference Mini DIP K 0-0 V ON 4-0 ma OFF VP- VP- S Fixed 0 Proportional Reference S VP- VP- 0 Stop mode S Free wheel 0 Ramp Setting other parameters see sections and 5

11 GENERAL INFORMATION Standard configuration: regulation with the integrated PI loop - PI reference using the local button or external reference - operating directions MAINS SUPPLY Fault relay L L L PE S + PI reference (local button or external reference) PI sensor feedback (0-) PI reference selection (local button or external reference) Run reverse / stop Run forward / stop Terminals Specifications +0 V analogue source rated current: ma Analogue input PI reference Analogue input - PI sensor feedback 0 to +0 V - Impedance = 00 kω 4 0 V - common with terminal 6 5 Logic input S PI reference selection 6 0 V - common with terminal 4 Logic input run reverse/stop Logic input run forward/stop Relay output 50 V - A Associated parameter setting CDC-VMA PEGASE VMA 0 Terminal block configuration P4 = 0 STANDARD P0 = Terminal N assignment PI input PI reference selection Reference S switches K K4 Local button - ON Ext. ref. 0-0 V 0 ON ON Ext. ref. 4-0 ma 0 OFF ON 9-0 Switched off or faulty On Setting other parameters see sections and 6

12 COMMISSIONING THE CDC-VMA CONSOLE - COMMISSIONING THE CDC-VMA CONSOLE. - Installation.. - Checks on receipt When you receive your CDC-VMA console, make sure that it has not been damaged during transport. If necessary, report any damage to the delivery company... - Connection - Open the front cover of the. - Connect the 0-pin socket on the end of the cable to the connector on the rolled cable. - The RS socket on the cable is connected to the console socket. THE CONSOLE KIT COMPRISES: - the CDC-VMA console - connection cable (length =.5 m) with RS socket. - power supply unit 0 V single phase - 50/60 Hz, - parameter-setting manual. en 0 V power supply 0-pin socket RS socket connector. - Presentation of the keypad CDC -VMA P0 FMIN. FREQUENCE MIN. HZ MIN. FREQUENCY HZ MIN. FREQUENZ HZ P0 REF 4MA ETALONNAGE CONSIGNE MIN. HZ MIN. REF. SCALING HZ ABGLEICH SOLLWERT MIN. HZ P0 F MAX. FREQUENCE MAX. HZ MAX. FREQUENCY HZ MAX. FREQUENZ HZ P04 REF 0MA ETALONNAGE CONSIGNE MAX. HZ MAX. REF. SCALING HZ ABGLEICH SOLLWERT MAX. HZ P05 ACCEL. RAMPE ACCEL. S ACCEL. RAMP S HOCHLAUF RAMPE S P06 DECEL. RAMPE DECEL. S DECEL. RAMP S AUSLAUF RAMPE S P0 STOP MODE MODE D'ARRET STOPPING MODE HALTE MODUS 0 = ROUE LIBRE = RAMPE 0 = FREE WHEEL = RAMP 0 = FREILAUF = RAMPE P0 U / F LOI U / F U / F RATIO U / F KENNLINIE 0 = FIXE = DYNAMIQUE 0 = FIXED = DYNAMIC 0 = FEST = DYNAMISCH P BOOST BOOST % BOOST % BOOST % P F MOT. LECTURE FREQUENCE MOTEUR HZ MOTOR FREQUENCY STATUS HZ MOTOR FREQUENZ ANZEIGE HZ P4 I MOT. LECTURE COURANT MOTEUR A/0 MOTOR CURRENT STATUS A/0 MOTOR STROM ANZEIGE A/0 MEM. Summary table of main parameters Keys for accessing and modifying the different parameters Key for storing settings

13 COMMISSIONING THE CDC-VMA CONSOLE. - Read mode.4 - Parameter-setting mode If when the console is powered up, it is not connected to the or if the VARMECA 0 is switched off, the message CONSOLE LINK FAULT will appear - Power up the. - Connect the 0 V socket on the console power supply unit. - On power-up, the console display is positioned on the st parameter PO FMIN. The st line of the display unit indicates the parameter designation. The nd line indicates the parameter value and unit. Parameter modifications must be performed with the stopped (run command disabled) To modify a setting, use the or keys to select the parameter. The key is used to make the parameter, which is to be modified, flash. Modify the setting value with the or keys. As soon as the value differs from the stored value, the MEM? message appears. The to P9. The key is used for scrolling through parameters P0 key is used for scrolling in the opposite direction. When the desired setting value has been reached, it can be stored using the MEM. key. The MEM? indication disappears. The key is used to quit the parameter-setting mode.

14 .5 - The parameters COMMISSIONING THE CDC-VMA CONSOLE List and description of the parameters which can be accessed by the CDC-VMA console Display Description Adjustment range in increments of Factory setting P0 F min minimum operating frequency 6 to 0 Hz Hz P0 REF 0 V - 4 ma calibration of the min. reference 0 V or 4 ma 0 to 0 Hz Hz P0 F max maximum operating frequency (according to mini DIP K position) to 0 Hz 50 or 0 Hz P04 REF 0 V - 0 ma calibration of the max. reference to 0 Hz 50 or 0 Hz P05 ACCEL. P06 DECEL. P0 STOP MODE P0 UN MOT () P09 FN MOT () P0 U / F () P BOOST () P OVER BOOST () P F PWM P4 CONFIG acceleration ramp ramp value to pass from 0 to 50 Hz deceleration ramp ramp value to pass from 50 to 0 Hz stop mode 0 = freewheel stop = stop according to ramp voltage applied to the motor from the base frequency (percentage of mains voltage: base 400 V) motor base frequency selection of voltage/frequency ratio 0 = fixed U / F the P0 voltage will be applied at the P0 frequency point = dynamic U / F the voltage adapts automatically to the motor load value of voltage applied in low frequencies (percentage of mains voltage) value of voltage during starting phase (percentage of mains voltage) switching frequency 0 = 4 khz = 6 khz = khz = khz terminal block configuration 0 = standard = option - preset speeds and operating directions = option - analogue reference and preset speeds - operating direction = option - correction of an external reference with the local button - operating directions 4 = option 4 - preset speeds proportional to the reference - operating direction 0 to 0 s s 0 to 0 s s 0 or 0 to 00 % 00 % 50 to 50 Hz 50 Hz 0 or 0 to 40 % 0 to 00 % 0 to 0 from 0.5 to. kw from.5 to.5 kw adapted to the motor according to the power adapted to the motor according to the power from 0.5 to. kw from to 4kW 0 to 4 0 P5 VP- preset speed in options and 4 6 to 0 Hz 50 Hz P6 VP- VP- preset speed in options and 4 or preset speed in option 6 to 0 Hz 60 Hz P VP- preset speed in option 6 to 0 Hz 40 Hz P VP- preset speed in option 6 to 0 Hz 0 Hz en () : the voltage/frequency ratio is illustrated at the end of the table 9

15 COMMISSIONING THE CDC-VMA CONSOLE Display Description Adjustment range in increments of Factory setting choice of directions of rotation in the configuration P9 ROTATION option 0 = clockwise = anti-clockwise 0 to 0 P0 SELECT terminal assignment 0 = speed image output 0 to 0 = PI feedback input P PI KPRO proportional gain of the PI loop to 00 0 P PI KINT integral gain of the PI loop to 00 0 P F_MOT motor operating frequency 0 to 0 Hz P4 I_MOT motor current (in tenths of an ampere) A/0 0 to 50% of I n P5 FAULT P6 STOP Fmin P LOG CDC-VMA P CAL MOT P9 last fault in memory fault code 0 = no fault = motor overheating = overvoltage = overcurrent 4 = locked rotor 5 = DC bus undervoltage 6 = EEPROM = serial link = power module fault enabling of the STOP USING REFERENCE function 0 = disabled = enabled when the reference is less than Fmin, it forces the motor to stop console software version power rating setting code of ratings 0 = 0. kw = 0.55 kw = 0.5 kw = 0.9 kw 4 =. kw 5 =.5 kw 6 =. kw =. kw = kw 9 = 4 kw 0 = 0.5 kw = test = special. kw = 5.5 kw 4 =.5 kw access code 0 to 0 0 to 0 0 to 4 reserved LEROY-SOMER adapted to the motor according to the power 0 Representation of voltage/frequency ratio U motor P0 P0 Dynamic U/F P P P09 F motor 40

16 COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE - COMMISSIONING THE PEGASE VMA 0 PC PARAMETER- SETTING SOFTWARE. - Connection.. - Checks on receipt When you receive your parameter-setting kit, make sure that it has not been damaged during transport. If necessary, report any damage to the delivery company. THE KIT COMPRISES: - connection cable (length = m) with RS socket. - disks or CD-ROM, - parameter-setting manual.. - Software installation - Start up your PC. - Insert disk n (or the CD ROM). - Open the "install" file. - Follow the instructions given on the screen, in particular those relating to changing disks. - When the "Installation complete" message appears, click on OK - The PEGASE VMA software is installed. en Depending on the PC used, the serial port may need to be reassigned if communication proves to be impossible (consult LEROY-SOMER) RS socket PEGASE 0-pin socket.. - Connection - The RS socket on the cable is connected to the RS socket on the PC. - The 0-pin socket on the cable connects to the connector on the rolled cable. connector 4

17 . - Use COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE - Double-click on the icon - The first window appears... - Detail of the st window Choice of language Go to next window Exit the current window.. - Detail of the nd window Power rating selected VARMECA software version Programming software version Go to next window Exit the current window 4

18 COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE.. - Detail of the rd window (access to parameters) Confirm parameter modifications en Return to previous window Exit the current window Parameter modifications must be made whilst the is powered up, but in the "stop" position (run command disabled).4 - The parameters Description of parameters which can be accessed from the PC. Display Description Adjustment range in increments of Factory setting F max maximum operating frequency (according to mini DIP K position) to 0 Hz 50 or 0 Hz F min minimum operating frequency 6 to 0 Hz Hz ACCEL acceleration ramp value to pass from 0 to 50 Hz 0 to 0 s s DECEL deceleration ramp value to pass from 50 to 0 Hz 0 to 0 s s U n mot () F n mot () BOOST () OVERBOOST () voltage applied to the motor at base frequency (percentage of mains voltage: base 400 V) 0 to 00 % 00 % base frequency of motor 50 to 50 Hz 50 Hz value of voltage applied in low frequencies (percentage of mains voltage) value of voltage applied during starting phase (percentage of mains voltage) 0 to 40 % 0 to 00 % () : the voltage/frequency ratio is illustrated at the end of the table adapted to the motor according to the power adapted to the motor according to the power 4

19 COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE Display Description Adjustment range in increments of Factory setting Max. reference point calibration of the max. reference 0 V or 0 ma to 0 Hz 50 or 0 Hz Min. reference point calibration of the min. reference 0 V or 4 ma 0 to 0 Hz Hz Stop mode choice of stop mode ramp or freewheel ramp auto U / F () selection of voltage/frequency ratio NO = fixed U / F ratio voltage U n mot is applied at the frequency point F n mot YES = dynamic U / F ratio the voltage adapts automatically to the motor load YES or NO F switching switching frequency 4, 6,, khz Terminal block configuration choice of terminal block configuration option = operating directions, preset speeds option = operating direction, preset speeds + reference option = correction of an external reference using the local button option 4 = preset speeds proportional to the reference standard, option, option, option, option 4 NO from 0.5 to. kw YES from.5 to.5 kw khz from 0.5 to. kw khz from to 4 kw standard VP option -4 preset speed in configuration options and 4 0 to 0 Hz 50 Hz VP option -4 VP option preset speed in configuration options and 4 or preset speed in configuration option 0 to 0 Hz 60 VP option preset speed in configuration option 0 to 0 Hz 40 Hz VP option preset speed in configuration option 0 to 0 Hz 0 Hz choice of terminal n assignment Terminal N assignment speed output = analogue output image of the V frequency 0 V = stop +0 V = max. frequency speed output or PI input speed output PI input = analogue input 0 to +0 V for the PI feedback PI : K proportional PI loop proportional gain setting to 00 0 PI : K integral PI loop integral gain setting to 00 0 enabling of stop by reference Stop by reference YES = when the reference is less than the minimum frequency, it forces the motor to stop NO = when the reference is less than the minimum frequency, the motor operates at the minimum frequency YES, NO () : the voltage/frequency ratio is illustrated at the end of the table NO 44

20 COMMISSIONING THE PEGASE VMA 0 PC PARAMETER-SETTING SOFTWARE Display Description Adjustment range in increments of F mot motor frequency reading 0 to 0 Hz reading V bus voltage of the speed controller DC bus V bus Vmains = reading from 0 to 00 V Factory setting Status speed controller status stop or run POSSIBLE INDICATIONS: no fault en motor overheating overvoltage Fault speed controller fault indication overcurrent locked rotor NO FAULT bus undervoltage EEPROM serial link module fault Representation of voltage/frequency ratio U motor U motor n Dynamic U/F Overboost Boost F motor n F motor 45

21 4 - TROUBLESHOOTING TROUBLESHOOTING Faults are indicated on the CDC-VMA console by a code from 0 to. With the PEGASE VMA 0 software the faults are indicated clearly in the fault window. The table below can be used to analyse faults and specifies any checks which should be performed. Fault code on CDC-VMA Indication of fault on PEGASE 0 NO FAULT 4 MOTOR OVERHEATING Red LED illuminated OVERVOLTAGE Red LED flashing OVERCURRENT Red LED illuminated LOCKED ROTOR Red LED illuminated Checks to make, possible causes overheating fault It - check if the motor is overloaded (orange LED illuminated) - check the set rating and the motor power - make sure that the boost adjustment (P) has not been modified - check the mains supply voltage - check that the deceleration ramp is long enough for applications with high inertia - check that there is no short circuit occurring from a motor winding or on the connections - check the motor insulation - check that the deceleration ramp is long enough for applications with high inertia - check the set rating and the motor power - internal product fault - check if the motor is overloaded or has stalled (green LED flashing) 5 6 BUS UNDERVOLTAGE Red LED flashing EEPROM Red LED illuminated SERIAL LINK Red LED illuminated MODULE FAULT Red LED illuminated Fault specific to the use of the CDC-VMA console Fault specific to the use of the software PEGASE VMA 0 - check the mains supply voltage - make sure that the is not affected by interference - internal product fault - communication fault between the EEPROM and the controller - product fault - very sudden overcurrent (possible causes: see OVERCURRENT fault) - IGBT power module overheating. Check that the unit is not operating at an ambient temperature which is too high - IGBT power module fault. Internal product fault FAULTS CAN ONLY BE CLEARED BY SWITCHING OFF THE. CONSOLE LINK FAULT - Check the connection cable. - Check that the is correctly supplied. COMMUNICATION PROBLEM WITH THE - Check the connection cable. - Check that the is correctly supplied. - Check that the serial port is correctly configured. 46

22 5 - SUMMARY OF SETTINGS SUMMARY OF SETTINGS The table below can be used to note the settings entered in the in order to keep a record should a replacement product be needed. Settings made using the CDC-VMA console Parameters P0 F MIN P0 REF 0 V -4 ma P0 F MAX P04 REF 0 V - 0 ma P05 ACCEL P06 DECEL. P0 STOP MODE P0 Un MOT P09 Fn MOT P0 U / F P BOOST P OVERBOOST P F PWM P4 CONFIG Value set Parameters P5 VP- P6 VP- VP- P VP- P VP- P9 ROTATION P0 SELECT P PI K PRO P PI K INT P F MOT P4 I MOT P5 FAULT P6 STOP Fmin P LOG CDC-VMA P CAL MOT Value set en Settings made using the PEGASE VMA 0 software 4

Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301

Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301 Réf. 335-4.33 / a -.98.5 X-.39 Synchro output speed reference Menu 3 Max. sp Min. spe Negativ speed s.4 Synchro out speed refere selection Menu 3 Skip frequency Skip width.29.3.3 g t Run Run FWD REV 27

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668) INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668) Use with Models KBDA-24D, 27D, 29, 45, 48 See Safety Warning, on page 4. RoHS The information contained in this

More information

13. Before making a service call Trip information and remedies

13. Before making a service call Trip information and remedies . Before making a service call Trip information and remedies.1 Trip causes/warnings and remedies When a problem arises, diagnose it in accordance with the following table. If it is found that replacement

More information

smd frequency inverter

smd frequency inverter S03B These Instructions contain important technical data and describe installation, operation and commissioning of the smd frequency inverter. are only valid for smd frequency inverters with software rev

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

POWERDRIVE Variable speed drive

POWERDRIVE Variable speed drive Control card Input/Output command Micro regulator ASIC PWM MD- Encoder (optional) This manual is to be given to the end user Mains supply Carrier power supply IGBT IGBT IGBT M (Optional encoder) Installation

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

6.9 Jump frequency - Avoiding frequency resonance

6.9 Jump frequency - Avoiding frequency resonance E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant

More information

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F Ametek, Inc. Rotron Technical Products Division 100 East Erie St., Suite 200 Kent, Ohio 44240 User's 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2"

More information

PROXIDRIVE IP66 variable speed drive

PROXIDRIVE IP66 variable speed drive ADI A ADIO3 DI4 SDI S 0- analogue reference 4-20mA analogue reference 0- motor speed image output Zero speed output Run FWD/Stop Run REV/Stop Selection of ADI/A Safety/Unlocking input This manual is to

More information

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External

More information

MICROMASTER. Operating Instructions

MICROMASTER. Operating Instructions MICROMASTER Operating Instructions Contents Safety Instructions...2 1. OVERVIEW...3 2. INSTALLATION...4 3. FRONT PANEL CONTROLS & BASIC OPERATION...14 4. OPERATING MODES...17 5. SYSTEM PARAMETERS...20

More information

Altivar 28 drive Altivar 28 enclosed drive

Altivar 28 drive Altivar 28 enclosed drive Telemecanique drive enclosed drive March 00 Characteristics : pages 0 to pages 4 to 2 Dimensions, schemes : pages 24 to 29 Presentation, functions Presentation A frequency inverter for -phase asynchronous

More information

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

Altivar 68 Telemecanique

Altivar 68 Telemecanique Altivar 68 Telemecanique Programming manual Variable speed drives for asynchronous motors Contents Installation recommendations 3 Control 7 A - Display of references and actual values and configuration

More information

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable

More information

POWERDRIVE Dual output variable speed drive

POWERDRIVE Dual output variable speed drive Bridge 1 control card Bridge 2 control card This manual is to be given to the end user I/O control Mains Micro controller ASIC PWM Switching mode power supply PX- Encoder option IGBT M I/O control Micro

More information

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual ACS 200 Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual Keep this User's Manual within easy reach. Warning symbols For

More information

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity

More information

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 191.76 USD Main Range of

More information

Frequency converter VAU 4/4 VAU(w) 7.5/3 VAU 11-22/3

Frequency converter VAU 4/4 VAU(w) 7.5/3 VAU 11-22/3 operating instructions Quick start guide Frequency converter VAU 4/4 VAU(w) 7.5/3 VAU 1122/3 28100241501 03/15 1 www.beckerinternational.com Table of Contents 1. Safety information...15 1.1 Warning symbols

More information

UMV Open or closed loop flux vector controller. Installation and maintenance. This manual must be given to the end user. Faster/slower function

UMV Open or closed loop flux vector controller. Installation and maintenance. This manual must be given to the end user. Faster/slower function Réf. 246 GB - 4.33 / d -. Faster/slower function 2.33 2.43 Joggin selectio This manual must be given to the end user Speed reference image 2.6 Speed ref. 2.3 Faster Slower term. UMV 33 Open or closed loop

More information

Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19. Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW

Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19. Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19 Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW Siemens G85139-H1751-U555-D1 0 of 23 CONTENS SAFETY AND CE

More information

User Guide. Optidrive Plus 3 GV Compact. OEM AC Variable Speed Drive kW (1 2HP) Installation and Operating Instructions

User Guide. Optidrive Plus 3 GV Compact. OEM AC Variable Speed Drive kW (1 2HP) Installation and Operating Instructions User Guide Optidrive Plus 3 GV Compact OEM AC Variable Speed Drive 0.75 1.5kW (1 2HP) Installation and Operating Instructions Declaration of Conformity: Invertek Drives Ltd hereby states that the Optidrive

More information

EC 45 flat with integrated electronics Document ID: en Operating Manual

EC 45 flat with integrated electronics Document ID: en Operating Manual EC 45 flat with integrated electronics Document ID: 919801en Operating Manual Edition June 2017 The EC 45 flat with integrated electronics is a brushless, speed-controlled 1-quadrant drive. It is available

More information

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG 6 5 4 7 8 9 C US 45 en -. / e 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG. KNEE 5Hz 65Hz 6Hz PHASE

More information

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

POWERDRIVE Regenerative variable speed drive

POWERDRIVE Regenerative variable speed drive This manual is to be given to the end user ter Sine filter Rectifying choke Preload Installation manual NOTE reserves the right to modify the characteristics of its products at any time in order to incorporate

More information

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2

More information

NX series Constant and variable torque Variable Speed Drives for induction motors

NX series Constant and variable torque Variable Speed Drives for induction motors Honeywell All in One Application Manual NX series Constant and variable torque Variable Speed Drives for induction motors Subject to changes without notice CONTENTS NX "All in One" APPLICATION MANUAL INDEX

More information

Commissioning manual. Powerdrive MD2/FX

Commissioning manual. Powerdrive MD2/FX Commissioning manual Powerdrive MD2/FX Référence : NOTE LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments.

More information

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , , maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers 249630, 249631, 249632, 318305, 381510 September 2009 edition The DEC (Digital EC Controller) is a 1-quadrant amplifier for controlling electronically

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866) DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL

POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL CIRCUIT DESCRIPTION Power Supplies SPS 1000 series are based on the primary switched AC/DC converters topology. Power supplies of

More information

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters. ~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES 8 7 9 6 5 4 C 45 en -. / a R 45 DETECT. PH PH. SENSING 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG.

More information

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual D.C. BRUSHLESS MOTORS DRIVE BLD07-IT Service Manual INTECNO s.r.l. Via Caduti di Sabbiuno n. 9/E 40011 Anzola Emilia (BO) - Italy tel. 051.19985350 fax 051.19985360 www.intecno-srl.com INDEX Description

More information

Technical Documentation

Technical Documentation Technical Documentation PROAM-21 Power amplifier for directional valves Grundlage der Funktionsbeschreibung und zur Prüfung der Module (keine Produktdokumentation). AMCA HYDRAULIC FLUID POWER B.V. P.O.BOX

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) D Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES KBDA SERIES ADJUSTABLE FREQUENCY DRIVES FOR 3-PHASE AC MOTORS NEMA-4X / IP-65 Washdown and Watertight for Indoor and Outdoor use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY Simplified Group Programming

More information

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company SERIES 70 R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL The High Performance Company Contents 1.0 Safety Instructions - Definition of Terms 2 1.1 Hazard-free Use 2 1.2 Qualified Personnel 2

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13 Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access

More information

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21 Product data sheet Characteristics ATV212HU22M3X variable speed drive ATV212-2.2kW - 3hp - 240V - 3ph - wo EMC - IP21 Product availability : Stock - Normally stocked in distribution facility Price* : 618.00

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Multi-function, Compact Inverters. 3G3MV Series

Multi-function, Compact Inverters. 3G3MV Series Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

ACS 300. User s Manual. ACS 300 Frequency Converters for Speed Control of 0.55 to 11 kw Squirrel Cage Motors

ACS 300. User s Manual. ACS 300 Frequency Converters for Speed Control of 0.55 to 11 kw Squirrel Cage Motors ACS 300 User s Manual ACS 300 Frequency Converters for Speed Control of 0.55 to 11 kw Squirrel Cage Motors ACS 300 Frequency Converters for Speed Control of 0.55 to 11 kw Squirrel Cage Motors User s Manual

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual Your Global Flow Control Partner Series 70 SERVO PRO Version 3.0 Table of Contents 1.0 Safety Instructions - Definition of Terms...........................2 1.1 Hazard-free Use.......................................2

More information

SX (400V) System configuration

SX (400V) System configuration ~ ~ SX (400V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

KSC-10 Kelvin Speed controller 10A Rev.00 of 23/01/17

KSC-10 Kelvin Speed controller 10A Rev.00 of 23/01/17 Kelvin Speed controller 10A Tel : +34 93 422 70 33 1 The KSC-10 is a 1 Quadrant digital servo amplifier for direct current motor with permanent magnets of up to 600 Watts. It permits speed regulation in

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

RMO500 M I C R O O H M M E T E R

RMO500 M I C R O O H M M E T E R M I C R O O H M M E T E R Reference Manual IBEKO POWER AB Sweden 2 IBEKO POWER AB Manual Version:. MV.01 IBEKO POWER AB 2003 This Reference Manual is a publication of IBEKO POWER AB, 18 125 Lidingö, Sweden.

More information

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

FREQUENCY INVERTER VFR-013 QUICK START GUIDE FREQUENCY INVERTER VFR-013 QUICK START GUIDE Inoréa Automation & Industry 9 rue du Lugan 33130 BEGLES www.inorea.com Table of contents 1. PEOPLE SAFETY... 3 2. MATERIAL SAFETY... 3 3. NAME PLATE... 4 a.

More information

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A) This manual must be sent to the end user X2 Z1 X1 Z2 E+ E- J1 t (12V - 10A) ~ 10 ohms Exciter field + - Isolated DC power supply Installation and maintenance WARNING TO AVOID HARM EITHER TO PEOPLE OR TO

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

A 1/10/2013. Hardware Manual STR2M Step Motor Drive

A 1/10/2013. Hardware Manual STR2M Step Motor Drive Hardware Manual 5000-235-001 STR2M Step Motor Drive 5000-235-001 STR2M Contents Safety Instructions... 3 Introduction... 5 Features... 5 Block Diagram... 6 Getting Started... 7 Mounting the Drive... 8

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) F Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47 8 7 9 6 5 4 5 Hz EXT FREQ 6 Hz SETTING VOLT. STAB. I EXC EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG. KNEE 65Hz 5Hz 6Hz PHASE SENSING MODE MODE MODE MODE LSA 49 / 5 LSA 46 / 47 7 / 8 5 / 6 LSA 49 / 5 7 /

More information

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number control 4-Q-EC Servoamplifier DES 70/10 Order number 228597 April 2006 Edition The DES (Digital EC Servoamplifier) is a very efficient digital servoamplifier with sinusoidal current commutation for perfectly

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Analog Servo Drive 25A20DD

Analog Servo Drive 25A20DD Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3 CHAPTER MAINTENANCE AND 6 TROUBLESHOOTING In This Chapter... Maintenance and Inspection.................6 2 Monthly Inspection:..................................6 2 Annual Inspection....................................6

More information

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number : Advanced user guide Commander SX IP66/Nema 4X AC Variable Speed Drive Part Number : NOTE CONTROL TECHNIQUES reserves the right to modify the characteristics of its products at any time in order to incorporate

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

Inverter Drive /Vector Drive Motors & Controls

Inverter Drive /Vector Drive Motors & Controls H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 50 180-264 VAC 3 Phase - 50/60 Hz 3/4 thru 60 340-528 VAC 3 Phase - 50/60 Hz 3/4 thru 60 515-660 VAC 3 Phase - 60 Hz HVAC

More information

FUJI Inverter. Standard Specifications

FUJI Inverter. Standard Specifications FUJI Inverter o Standard Specifications Norminal applied motor The rated output of a general-purpose motor, stated in kw. That is used as a standard motor. Rated capacity The rating of an output capacity,

More information

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces: Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-VSPA2-50 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block circuit diagram

More information

IF30. User's manual. Description. Table of contents IF30

IF30. User's manual. Description. Table of contents IF30 User's manual IF30 Description IF30 is an encoder interface unit designed to convert the output signals delivered by so-called sine-cosine-encoders and similar measuring systems (devices which deliver

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 8 9 R T DETECT. PH PH. SENSING Hz EXT FREQ Hz SETTING VOLT. STAB. I EXC EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG. KNEE Hz Hz MODE MODE MODE MODE Hz VOLTAGE V ~ V LSA 9 / LSA / / 8 / LSA 9 / LSA / / 8

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

SAFETY INSTRUCTIONS WARNING

SAFETY INSTRUCTIONS WARNING Important User Information Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information