Phase Comparison of High Current Shunts up to 100 khz

Size: px
Start display at page:

Download "Phase Comparison of High Current Shunts up to 100 khz"

Transcription

1 Accepted for publication in IEEE I&M 1 Phase Comparison of High Current Shunts up to 100 khz ian Carlo Bosco, Martin arcocz, Kåre Lind, Umberto Pogliano, ert Rietveld, Valter Tarasso, Boštjan Voljč. and Věra Nováková Zachovalová. Abstract - A comparison of the phase error of existing shunts for currents between 10 A and 100 A and frequencies from 500 Hz to 100 khz has been organized. The measurements were performed at INRIM on some shunts using the first prototype of a new type of phase comparator and a step-up method for the data processing. The results of the relative measurements have shown a good repeatability. The method for the evaluation of the reference value was based on similar shunts and suitable assumptions and derived by extrapolation. For the type of the resistance elements employed in these shunts, the derivation of the reference is not very accurate and still needs to be improved. Index Terms Measurement, Electrical variable measurement, Measurement standards, Current measurement, Phase measurement T I. INTRODUCTION HE measurement of power and power quality with high accuracy needs a lot of skill and competence in a wide area of ac measurements. So, a co-operation activity was undertaken between many national metrological institutes (NMIs) in the framework of a imera Plus project The Next eneration of Power and Energy Measurements. In this project it was recognized that the current state-of-the-art in ac power metrology was mainly involving sinewave signals and that NMIs were not adequately equipped to underpin a regulatory system for power quality. For this purpose some Manuscript received June 5, The research presented in this paper is part of the EURAMET joint research project on "Power and Energy" and has received funding from the European Community's Seventh Framework Programme, ERA-NET Plus, under rant Agreement No C. Bosco and U. Pogliano are with the Electromagnetics Division of the Istituto Nationale di Ricerca Metrologica (I.N.RI.M), Strada delle Cacce 91, 10135, Torino, Italy. M. arcocz is with the Bundesamt für Eich und Vermessungswesen (BEV), Arltgasse 35, Vienna, Austia. K. Lind is with the Justervesenet-Norwegian Metrology Service, Fetveien 99, N-2007 Kjeller, Norway.. Rietveld is with the Van Swinden Laboratorium (VSL), Thijsseweg 11, 2629 JA Delft, The Netherlands. V. Tarasso is with the Technical Research Institute of Sweden (SP), Box 857, SE , Boras, Sweden. B. Voljč. is with the Slovenian Institute of Quality and Metrology (SIQ), Trzaska 2, 1000 Lubjana, Slovenia. V. N. Zachovalová is with.český Metrologický Institut (CMI), Okruzni 31, Brno, Czech Republic. Correspondent author U. Pogliano, phone: ; fax: ; u.pogliano@inrim.it. technological objectives were defined, such as for example to accurately measure ac voltage and current waveforms that are highly distorted, contain discontinuities and are non-stationary. An essential part of ac metrology for power measurement, mainly where digitizers are employed, is scaling the voltage signals and converting current into voltage from the working levels to values convenient for the inputs of the digitizer. The transducers used for these aims must be stable and insensitive to temperature and signal level. They also need a phase error that is both low and stable within the bandwidth of interest. For current measurements the project aim is to develop shunts with different current ranges, having high stability of impedance with load current, temperature and time, starting from the technology already available. The first type of technology is the so-called cage designs, where a number of resistive elements are connected in parallel, in a cylindrical in cage-like design. This configuration has the advantages of reducing the self-inductance by connecting in parallel the resistive elements and of dissipating efficiently the heat produced. The second technology for shunt construction utilizes a coaxial structure of resistive alloys in metal foils arranged in coaxial structures which minimizes the space between the current paths, so reducing the inductance that, for these shunts, is the main source of error and phase shift. Analytical models can lead to proper design, with minimization of stray parameters and optimization of these shunts for absolute measurements of current and phase angle. However, beside models, there is always the need of an experimental verification. So, the measurement of the impedance components of the shunts and their changes with frequency is required and methods for such characterization have been undertaken in this study. In particular, while other laboratories have investigated other types of problems, at INRIM the measurements of the phase for high current shunts (over 10 A) has been considered and a phase comparator has been developed. The characterization performed and reported in this paper is related to the existing shunts, in the range form 10 A to 100 A, built by different laboratories [1], [2], [3], [4], [5], [6]. The aim of this comparison, beside the construction of the reference for phase (as for example in [7]), is to establish a connection between the analytical models and the resulting devices. Then, in the following part of the project, the measurements will be applied to the characterization of the shunts produced in the project.

2 Accepted for publication in IEEE I&M 2 A. The phase comparator II. COMPARISON METHOD The measurements of phase differences between two shunts were performed by means of a phase comparator, which was specifically built for this purpose and which is a first simplified version of a model studied at INRIM for this project. AC CURRENT ENERATOR SH2 SH1 The design of the phase comparator has already been partially reported in [8], and it is going to be more extensively described in [9]. Its basic scheme, shown in Fig. 1, contains an ac current generator (built by connecting an AC calibrator to the input of a transconductance amplifier). The resulting generator is suitable for currents up to 100 A in the frequency range up to 100 khz. It supplies the inputs of the two shunts under comparison connected in series. The outputs of the two shunts are connected to a two-input phase analyzer through two active guarded transformers (ATs) employed as wideband decoupled precision voltage transmitters. The two ATs, of identical construction, with relatively low phase errors (about 350 rad at 100 khz), are made as double stage transformers with two separate screens between the primary and the secondary windings. One screen is connected to one side of the input, while the other one is connected to the reference ground of the output. A buffer supplied by rechargeable batteries drives the magnetizing winding. In the first prototype used for this comparison the phase detector was built using a commercial board put inside the computer. Two synchronized inputs of this board, operating at a sampling rate up to 1 Msamples/s with 16 bits resolution are employed for the phase determination. The phase relation of the two signals between the outputs of the active transformers and the inputs of the phase detector is maintained by connectors and balanced cables. The current generator and the digitizing board are controlled by a computer that sets the desired currents at the suitable frequencies and drives the digitizing board to acquire the samples, which are subsequently processed to derive the phase difference between the two inputs. B. The program for the determination of the phase A software program was developed for acquiring and processing the samples of the two signals at the output of the AT AT Fig. 1 Basic circuit of the comparison system. SH1 and SH2 denote the two shunts being compared. Two active guarded transformers (ATs) are employed as wideband decoupled precision transmitters. IN2 DIITAL PHASE ANALYSER IN1 shunts. Here??? the sampling rate, for the best phase resolution, is generally near the maximum (about 1 Msample/s), the samples are simultaneously acquired in a selected number, as consecutive bursts of nominally simultaneous samples from the two inputs. For each burst the phase is evaluated by an asynchronous method evaluating first the frequency throughout the zero transitions [9] and, then, the phase by the best fit on the fundamental. The mean and the standard deviation of all burst of a group of measurement are eventually computed and produced as a result of the measurement for each current and frequency. A. Data acquisition III. MEASUREMENT PROCEDURE The procedure for measurements employed for this comparison was developed after some preliminary investigations with the data obtained in experimental tests, made by means of the phase comparator. The repeatability of these results was analyzed in order to take the greatest advantage of the time employed in the process. Then, the procedure for the measurement of the phase difference between two shunts for this specific comparison was set up and standardized. 1) For each pair of shunts under comparison, they are firstly put in series, with the external screen of one of them connected to the ground potential and the other one with its screen connected to the opposite side of the current generator, as in Fig. 2a. In this connection an exact opposite current is applied to the High terminals of the two shunts and the stray capacitive currents produced by the screen voltages do not flow within the shunts, with only a relatively small effect on the phase of the shunt output (if the screen resistance is low). SH2 SH1 AT2 a) AT1 b) SH1 SH2 2) Three sets of measurement samples are taken for each current and for each frequency planned for this couple of shunts. Every set consists of 38 bursts of consecutive samples for both voltages at the outputs of the two shunts. The sample rate for all measurement frequencies is 800 ksample/s. The two series of data are acquired and stored in the computer and, then, with a AT2 AT1 Fig. 2 a and b. Connections of the shunts SH1 and SH2 with the two active guarded transformers (ATs) at the input of the phase comparator, in the two successive measurements for the compensation of the systematic errors

3 Accepted for publication in IEEE I&M 3 proper software, the controller of the phase comparator evaluates the values of the phase differences for every burst [9]. 3) The same shunts are then put in series in the reversed order, see Fig. 2b, and the same inversion is also applied in the connections of the external screens of the ATs. In this way the voltages applied to the guards of the ATs are the same for both measurements and the phase shifts of each of them does not change. Finally, three other sets of measurements are taken with the same methodology as before. After the measurement, the phase differences for each burst are stored in a file and a first processing is performed by an automatic program assisted by the operator. During this processing the operator inspects the graphs of the measurement results for all bursts to see the consistency of the data and the possible presence of outlayers. If any of them are found, they are removed from the results. This was found necessary especially for higher frequencies where, for the noise, sometimes the program for the identification of the frequency fails and, consequently, produces a wrong value of the phase. This first processing evaluates the mean values for each measurement set and for the three sets together and the related standard deviations. B. Compensation of systematic errors Three sets of measurements, with an inversion in the series of the shunts, have been introduced in order to cancel some of the systematic errors in the comparator and the non negligible phase errors of the ATs. In the measurement process the data are taken with the shunts put in series in a given order and, then, in the reversed order. In this way, the phase differences of the signals measured by in each position ( A and B ) are related to the phase of the two shunts ( SH1 and SH2 ) by the relations [8]: A B S H2 S H1, (1) 2 while the quantity: A B (2) 2 is the phase difference between the two channels and it is specific for the phase comparator. Its stability for a given frequency indicates the good functioning of the measurement system. Its value depends on the frequency, it is approximately linear with frequency and in the worst conditions at 50 A and 100 khz is about 1.5 mrad with a spread of variations, when the measurement works correctly, contained in 130 rad (standard deviation). Eventually, the phase difference of the two-shunt comparison is computed by relation (1) and its standard deviation is obtained by the square root of the quadratic composition of the components. IV. DATA PROCESSIN AND UNCERTAINTY EVALUATION A. Comparison between the shunts at the same current The differences of the phases between two shunts and the standard deviations resulting from the measurements performed by the procedure in the previous chapter are the starting point for processing the results and deriving the uncertainty budget. Additional components of uncertainty (type B) for each measurement link has been derived from specific tests performed on the comparator [9]. The possible effect of the Tee was tested for some measurements at 20 A by using two very different models: one built by about 50 cm of coaxial cable connected with a brass box and two N connector, the other one, for high currents, built by a quasi-coaxial structure (internal part in copper and external part in aluminum) with LC connectors (for connection proper LC-N adapters have been used). The differences in the results were found in the normal spread of the results and a specific uncertainty component for the Tee was not taken into account in the budget. The data processing on the whole measurement set at the same current is aimed at consolidating the results to satisfy the additional requirement introduced by the coherence principle, which demands that, in all closed loops, the sum of the phase differences is zero. These additional constraints allow to adjust the resulting values by means of a suitable optimization performed by a best fit which also can estimate the uncertainties as a function of the frequency. For this purpose after the collection of measurement data between all shunts, the data were organized in separate groups one group for each current value and for every group a diagram of the comparison links was derived from the measurement data. For each frequency, the values are adjusted by a best fit to obtain a null sum of the residuals in every closed loop of these diagrams, minimizing the quadratic sum of the displacements. The evaluation of the uncertainty is made a priori from the means of the variance divided by the number of degrees of freedom in the comparison [10]. A successive evaluation can be made a posteriori from the quadratic mean of the displacements. The maximum of these two values, multiplied by a proper coverage factor, is taken as the expanded uncertainty for the phase difference of one shunt relative to others of the same group. Specifically, for all the four measurement groups considered, the a-priory estimated uncertainties were greater than the a-posteriori ones, which indicate that main uncertainty components taken into account, were not underestimated. B. Linking the phase of the shunts at different current To link the phase differences of the shunts with different nominal current, a typical step-up procedure, widely used in ac-dc transfer difference measurement, has been utilized. In a group of measurements at the same current the shunts that are considered are generally those that have the same nominal current. However some additional shunts with higher nominal current are also introduced into the group. These shunts are also associated with a measurement group of higher current. This allows us to link the values of the phase differences,

4 Accepted for publication in IEEE I&M 4 between measurements made at different current. For the determination of the relative value of the phase difference, one of the shunts is taken as a preliminary reference and the optimization inside the group of the measurements a step-up and a step-down is performed. For each step a specific shunt is assumed to have the same phase difference at two currents with an additional uncertainty that can be evaluated by the relative changes of the shunts measured at the two currents. between the two groups in the step-up. The same happens also for the shunt V1240A2, which is used only for the determination of the step-up uncertainty. An analogous procedure was applied for linking the 50 A group of measurement, which is shown in Fig. 5 and the one of 100 A shown in Fig. 6. In this case, unfortunately, the number of shunts involved was only three, resulting in a smaller V. COMPARISON RESULTS A. Determination of the relative phase differences The first step for measuring the phases of the shunts was the determination of the relative phases. The shunts sent by the NMIs and those of INRIM (some of them acquired as commercial products) were considered in the investigation. Four groups of measurements were organized, respectively, at the currents of 10 A, 20 A, 50 A and 100 A. The frequencies Fig. 4 Comparisons the phase difference between the shunt at 20 A Fig. 3 Comparisons the phase difference between the shunt at 10 A the boxes represent the shunts under comparisons, while the arrows the measurement links. Fig. 5 Comparisons the phase difference between the shunt at 50 A Fig. 6 Comparisons the phase difference between the shunt at 100 A considered were: 500 Hz, 1 khz, 2 khz, 5 khz, 10 khz, 20 khz, 50 khz and 100 khz. The structure of the measurements at 10 A is shown in Fig. 3. One of the shunts (denoted by the label V1620A3) was taken as the relative reference. The same shunt, having a nominal current of 20 A, is also in the graphs shown in Fig. 4 of the measurements at the current of 20 A and is the link reduction of the uncertainties due to the optimization. By applying in sequence the concept illustrated in chapter III and IV, the value of the relevant uncertainty can be computed. Table I shows these relative phase differences of each shunt (if a shunt is used to as a step-up element the same value is reported for both currents). In the second column the type of shunt is indicated (MF = metal foil, CL = cage-like, O = other). In the last lines the relative uncertainty at each current value is reported. B. Reference value The phases evaluated in the previous section are relative to the phase of the shunt V1620A3 at 10 A, which is taken as a

5 Accepted for publication in IEEE I&M 5 reference. In order to evaluate the absolute phases of all shunts linked in the measurement it is necessary to compute with some method the absolute phase of this shunt. The value was evaluated firstly using a step-down procedure, like that shown in the previous section, for the steps 5 A, 2 A, 1 A and 0.5 A and deriving the relative values of the relative phases of the shunts involved. TABLE I RELATIVE PHASE OF THE SHUNTS UNDER COMPARISON, RELATIVE TO THE SHUNT V16A20A3 AT 10 A VALUE IN mrad, UNCERTAINTIES COVERAE FACTOR (k=2) Type I 500 Hz 1 khz 2 khz 5 khz 10 khz 20 khz 50 khz 100 khz B7A10A MF CMI10A1 CL JVNT10A CL MU10ASIQ CL TDA20A O A40A20A O A40B50A CL HT20A O TDA20A O V1240A2 MF V1280A2 MF A40B50A CL CS1D0701 CL CS2D0702 CL V1280A2 MF CS1D0701 CL CS2D0702 CL V1280A2 MF U U U U A determination of the absolute value of the reference was accomplished by considering that at INRIM there were three types of shunts of identical structure having nominal currents of 2 A, 1 A and 0.5 A (a couple of each of them), and The phase of the reference shunt V1620A3 as a function of the frequency is shown in Table II with the expanded uncertainties. From these values it is possible to derive, by composition with the data in Table I, all the absolute phases and the uncertainties for all the shunt taking part in the comparison. TABLE II PHASE OF THE REFERENCE SHUNT IN mrad, UNCERTAINTIES COVERAE FACTOR (k=2) I 500 Hz 1 khz 2 khz 5 khz 10 khz 20 khz 50 khz 100 khz V1620A U C. Summary of the results From the results of the comparison, much information about the phases of the different shunts could be derived. At 10 A, which was the best measurement point, given the large number of shunts and measurements between them, the expanded uncertainty of the phase differences was less than 6 rad up to 10 khz and about 40 rad at 100 khz. The uncertainty increases respectively to about 30 rad and 250 rad at the same frequencies for the shunts measured at 50 A. In the absolute determination of phase, the uncertainty in all shunts is dominated by the uncertainty of the reference. In fact, by reasonable assumptions, the expanded uncertainty of the reference has been evaluated to be less than 60 rad up to 10 khz and 600 rad to 100 khz. The phase of all studied shunts built by NMIs, in the 10 A to 100 A range was generally linear as a function of frequency (a slight nonlinearity was observed over 50 khz in MF type of shunts) and very stable, even thought up to now the measurement were repeated only within less than one year. For all the shunts, apart from a 20 A preliminary prototype from INRIM (TDA20), the spread of the results was contained within 60 rad/khz. Fig. 7 Internal resistive structure of the 2 A, 1 A, 0.5 A shunts employed for deriving the absolute reference for phase resistance R respectively of 0.5, 1, 2. From the identical internal construction, shown if Fig. 7, the same value of the inductance L was assumed, even if the contribution of the inductance of the resistive components is not negligible, and can be different for each one of them. Then, the reference value was computed by assuming that, for every pair of shunts of this type and with different resistances, the absolute of phase error values can be obtained from the relative ones, considering their time constants proportional to 1/R. So, the differences of the time constants can be assumed from the measurements, while their ratio is given by the inverse proportionality of the resistances. As there are several shunts different available, possible extrapolations are possible and their spread was considered as an indication of the accuracy. VI. CONCLUSIONS The phase values for a set of 10 A to 100 A shunts have been measured up to 100 khz and the values obtained seem to be stable in time and linear as a function of the frequency. This comparison and the other tests were performed for characterizing the shunts already built. The data collected are useful, within the project, for identifying the models that are more suitable for the different current ranges and for improving the design of the shunts. In fact, in the design process, it is necessary to improve the models by identifying the differences between their previsions and the experimental results. Furthermore, the results will be useful, with an improved phase comparator and a new determination of the reference, to characterize the prototype of the shunt built in the project. At the moment, the accuracy level of the determination of the reference is not satisfactory. However, by using the described method of the evaluation by extrapolation, with suitable metal film shunts (one of which has been already

6 Accepted for publication in IEEE I&M 6 built), it will be possible to widely improve the accuracy of this determination, because in this case the inductance of each element is almost equal. REFERENCES [1] M. arcocz, P. Scheibenreiter, W. Waldmann and. Heine: Expanding the measurement capability for AC-DC Current Transfer at BEV, CPEM 2004 Digest, pp [2] K. Lind, T. Sorsdal, H. Slinde, Design, Modeling, and Verification of High-Performance AC DC Current Shunts From Inexpensive Components, IEEE Trans. on Instr. and Meas., vol. 57, no. 1, pp , [3] K. -E. Rydler, V. Tarasso, Extending ac-dc current transfer measurement to 100 A, 100 khz, CPEM 2008 Digest, pp [4] V. N. Zachovalova, AC-DC current transfer difference in CMI, CPEM 2008 Digest, pp [5] B. Voljc, M. Lindic, R. Lapuh, Direct Measurement of AC Current by Measuring the Voltage Drop on the Coaxial Current Shunt, IEEE Trans. on Instr. and Meas., vol. 58, no. 4, pp , [6] U. Pogliano,. C. Bosco, D. Serazio, Coaxial Shunts as AC DC Transfer Standards of Current, IEEE Trans. on Instr. and Meas., vol. 58, no. 4, pp , [7] I. Budovsky, "Measurement of Phase Angle Errors of Precision Current Shunts in the Frequency Range From 40 Hz to 200 khz," in IEEE Trans. on Instr. and Meas., vol 56, no 2, pp , [8] U. Pogliano, D. Serazio, B. Trinchera, Wideband Phase Comparator for High Current Shunts, CPEM 2010 Digest, Deajeon, Korea, June [9] U. Pogliano, D. Serazio, B. Trinchera, Wideband Phase Comparator for High Current Shunts, submitted to IEEE Trans. on Instr. and Meas. [10] O. Cardfeld, The Use of an Electric Network Analogue in Least Square Method Evaluations of Measurements, Metrologia, vol. 5, no. 2, ian Carlo Bosco was born in Turin, Italy, in He received the high school degree in electrotechnics in He joined the Electrical Metrology Department of the Istituto Elettrotecnico Nazionale "alileo Ferraris," now Istituto Nazionale di Ricerca Metrologica (I.N.RI.M.), Turin, in 1967, where he has been involved in low-frequency measurements devoted particularly to establish and maintain the standards of inductance, capacitance and ac-dc transfer. At present he is responsible for the calibration activity in electrical metrology. Martin arcocz was born in Vienna, Austria, in He received the Ing. degree in electrical engineering from the Höhere Technische Bundes- Lehr- und Versuchsanstalt Vienna in He joined the Bundesamt für Eich- und Vermessungswesen (BEV), Vienna, in 1977 and is working in the field of ac-dc transfer and ac quantities. Since 2004 he is head of the laboratory Electrical Quantities at BEV. Kåre Lind was born in Tromsø, Norway, in He received the degree sivilingeniør in electrical engineering from the Norwegian Institute of Technology, Trondheim, in He joined the Norwegian Telecom s Research and Development department (NT R&D), where he worked on the development of calibration, test, and measurement methods for telecom equipment. In 1986, he became the Head of the calibration and measurement methods group at NT R&D. The group was granted accreditation as an electrical calibration laboratory in In addition, he was engaged in microwave radio propagation studies. In 1998, he joined Justervesenet, the Norwegian metrology and accreditation service, Kjeller, Norway, where he currently works primarily with time and frequency and developing methods for electrical calibration. Umberto Pogliano was born in Leinì, Turin, Italy, in He received the Dr. Ing. degree in Electronic Engineering in 1975 and the Ph.D degree in metrology in 1987, both from the Politecnico di Torino. In 1977 he joined the Electrical Metrology Department of the Istituto Elettrotecnico Nazionale "alileo Ferraris," now Istituto Nazionale di Ricerca Metrologica (I.N.RI.M.), Turin. His research activity has been focused on the modelling of standards, on the development of systems and procedures in the field of precision dc and ac low-frequency measurements. At present his main interests are in the ac-dc transfer standard, in the ac voltage, current and power measurements, and in the generation, acquisition and reconstruction of electrical signals. From 2002 to 2007 he was responsible for the Electrical Metrology Department and now is he responsible for the research group The metrology of voltage, current and power in variable regime and in high frequency. Dr. Pogliano is an Italian delegate of CCEM and TC4. ert Rietveld was born in The Netherlands in He received the M.Sc. (cum laude) and Ph.D. degrees in low temperature and solid state physics from the Delft University of Technology, Delft, The Netherlands, in 1988 and 1993, respectively. In 1993, he joined VSL (Van Swinden Laboratorium), Delft, where he is a senior scientist in the DC/LF group of the Research & Development Department. He is involved in the development of power measurement systems and electrical quantum standards, especially the quantum Hall resistance standard. Other scientific work concerns the measurement of very small electrical currents and evaluation of selfcalibrating instruments. In addition he has worked as a program manager, coordinating the scientific work of all technological areas within VSL. Dr. Rietveld is a member of the Consultative Committee for Electricity and Magnetism (CCEM) of the International Bureau of Weights and Measures (BIPM), the contact person for VSL in the technical committee of electricity and magnetism (TCEM) of the European Association of National Metrology Institutes (EURAMET), and a member of several CCEM and EURAMET working groups. Valter Tarasso was born is Sweden in He received the M.S. degree in electrical engineering from Chalmers University of Technology, othenburg, Sweden, in He joined the Electrical Metrology Laboratory at SP Technical Research Institute of Sweden in He is involved in calibration and development of measuring methods for electrical ac low frequency quantities and ac-dc transfer of voltage and current. Internationally he is actively participating in EURAMET SC-LF group.

7 Accepted for publication in IEEE I&M 7 Boštjan Voljč was born in Ljubljana, Slovenia, in He received the B.Sc. degree in electrical engineering from the University of Ljubljana in In 2001, he joined the Slovenian Institute of Quality and Metrology (SIQ), Ljubljana, where he is currently a Senior Calibration Engineer. He is in charge of maintaining the national standard of electric current and is also a speaker at metrology related seminars. He has recently been involved in local and international research projects. His research interests include precision ac voltage and ac current measurements. Mr. Voljč is a member of the EURAMET Technical Committee for Electricity and Magnetism, of the Subcommittee for Low Frequency and Subcommittee for Power and Energy. Vera Novakova Zachovalova was born in Znojmo, Czech Republic, in She received the Ing. degree in electrical engineering from Brno University of Technology in In 2005 she joined the Department of DC and LF electrical quantities of the Czech Metrology Institute (CMI). She is responsible for AC-DC transfer difference and AC voltage and current traceability. She is involved in several national and international research projects.

New generation of cage-type current shunts at CMI

New generation of cage-type current shunts at CMI 20th IMEKO TC4 International Symposium and 18th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn Benevento, Italy, September 15-17,

More information

New generation of cage type current shunts developed using model analysis

New generation of cage type current shunts developed using model analysis ACTA IMEKO ISSN: 2221 870X September 2015, Volume 4, Number 3, 59 64 New generation of cage type s developed using model analysis Věra Nováková Zachovalová, Martin Šíra, Pavel Bednář, Stanislav Mašláň

More information

arxiv: v1 [physics.ins-det] 4 Oct 2011

arxiv: v1 [physics.ins-det] 4 Oct 2011 arxiv:1110.0866v1 [physics.ins-det] 4 Oct 2011 Wideband digital phase comparator for high current shunts Umberto Pogliano, Bruno Trinchera and Danilo Serazio Istituto Nazionale di Ricerca Metrologica (INRIM),

More information

Ac-dc transfer standard shunts for frequencies up to 1 MHz. U. Pogliano, C.G. Bosco, M. Lanzillotti, D Serazio

Ac-dc transfer standard shunts for frequencies up to 1 MHz. U. Pogliano, C.G. Bosco, M. Lanzillotti, D Serazio Ac-dc transfer standard shunts for frequencies up to 1 MHz U. Pogliano, C.G. Bosco, M. Lanzillotti, D Serazio Istituto Nazionale di Ricerca Metrologica (I.N.RI.M.) Strada delle Cacce 91 10135 Torino -

More information

Validation Of The New Automatic System For AC Voltage Comparisons. Umberto Pogliano, Gian Carlo Bosco and Marco Lanzillotti

Validation Of The New Automatic System For AC Voltage Comparisons. Umberto Pogliano, Gian Carlo Bosco and Marco Lanzillotti Validation Of The New Automatic System For AC Voltage Comparisons Umberto Pogliano, Gian Carlo Bosco and Marco Lanzillotti Istituto Elettrotecnico Galileo Ferraris,Strada delle Cacce 91, 10135 Torino,

More information

THE ELECTROMETRIC AC-DC TRANSFER STANDARD AS PRIMARY STANDARD AT IEN FOR AC VOLTAGES FROM 300 V TO 1000 V

THE ELECTROMETRIC AC-DC TRANSFER STANDARD AS PRIMARY STANDARD AT IEN FOR AC VOLTAGES FROM 300 V TO 1000 V THE ELECTROMETRIC AC-DC TRANER TANDARD A PRIMARY TANDARD AT IEN OR AC VOLTAGE ROM 300 V TO 1000 V U. Pogliano and G.C. Bosco Istituto Elettrotecnico Nazionale "Galileo erraris" trada delle Cacce 9, 10135

More information

COAXIAL CURRENT SHUNTS FROM 1 ma TO 100 A

COAXIAL CURRENT SHUNTS FROM 1 ma TO 100 A COAXIAL CURRENT SHUNTS FROM 1 ma TO 100 A B. Voljč, M. Lindič, B. Pinter, R. Lapuh, Z.Svetik SIQ - Slovenian Institute of Quality and Metrology, Slovenia info.metrology@siq.si; www.siq.si 1 Coaxial current

More information

Publishable JRP Summary for Project T4 J03 JOSY. Next generation of quantum voltage systems for wide range applications

Publishable JRP Summary for Project T4 J03 JOSY. Next generation of quantum voltage systems for wide range applications Publishable JRP Summary for Project T4 J3 JOSY Next generation of quantum voltage systems for wide range applications The main objective of this project is to introduce quantum-based measurement systems

More information

AC-DC TCC with Built-in Tee Connector for Accurate Calibrations

AC-DC TCC with Built-in Tee Connector for Accurate Calibrations AC-DC TCC with Built-in Tee Connector for Accurate Calibrations Rasha S. M. Ali Electrical Quantities Metrology Laboratory, National Institute of Standards (NIS), Egypt E-mail: rasha_sama79@hotmail.com

More information

Power Quality Measurements the Importance of Traceable Calibration

Power Quality Measurements the Importance of Traceable Calibration Power Quality Measurements the Importance of Traceable Calibration H.E. van den Brom and D. Hoogenboom VSL Dutch Metrology Institute, Delft, the Netherlands, hvdbrom@vsl.nl Summary: Standardization has

More information

A Synchronized Two-Phase Sinewave Generator for AC Metrology System Compensations

A Synchronized Two-Phase Sinewave Generator for AC Metrology System Compensations 320 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 49, NO. 2, APRIL 2000 A Synchronized Two-Phase Sinewave Generator for AC Metrology System Compensations Luca Callegaro and Vincenzo D Elia

More information

Wideband resistive voltage divider for a standard wattmeter

Wideband resistive voltage divider for a standard wattmeter Journal of Physics: Conference Series PAPER OPEN ACCESS Wideband resistive voltage divider for a standard wattmeter To cite this article: D Slomovitz et al 2016 J. Phys.: Conf. Ser. 733 012072 Recent citations

More information

1 Ω 10 kω High Precision Resistance Setup to calibrate Multifunction Electrical instruments

1 Ω 10 kω High Precision Resistance Setup to calibrate Multifunction Electrical instruments 20th IMEKO TC4 International Symposium and 18th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn enevento, Italy, September 15-17,

More information

Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability

Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability 17 th Symposium IMEKO TC, 3 rd Symposium IMEKO TC 19 and 15 th IWDC Workshop Sept. -1, 1, Kosice, Slovakia Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability. Morando 1, M. Borsero,.

More information

Two different ways in evaluating the uncertainty of S-parameter measurements

Two different ways in evaluating the uncertainty of S-parameter measurements th IMEKO TC International Symposium and 8th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn Benevento, Italy, September 57, Two

More information

RF-POWER STANDARD FROM AC-DC THERMAL CONVERTER. L. Brunetti, L. Oberto, M. Sellone

RF-POWER STANDARD FROM AC-DC THERMAL CONVERTER. L. Brunetti, L. Oberto, M. Sellone RF-POWER STANDARD FROM AC-DC THERMAL CONVERTER L. Brunetti, L. Oberto, M. Sellone Istituto Nazionale di Ricerca in Metrologia (INRIM) Strada delle Cacce 91, 10135 Torino, Italia Tel: + 39 (0)11 3919323,

More information

Use of the BVD for traceability of bipolar DC voltage scale from 1 mv up to 1200 V

Use of the BVD for traceability of bipolar DC voltage scale from 1 mv up to 1200 V Use of the BVD for traceability of bipolar DC voltage scale from 1 mv up to 1200 V Speaker: Roman Honig, MI-Europe, Druzstevni 845, 686 05 Uherske Hradiste, Czech Republic, Tel.: #420 731 440 665, Fax:

More information

A New Method for the Calibration of the mv Ranges of an AC Measurement Standard

A New Method for the Calibration of the mv Ranges of an AC Measurement Standard A New Method for the Calibration of the mv Ranges of an AC Measurement Standard Speaker/Author Neil Faulkner Fluke Corporation PO Box 9090, Everett, WA 98206 Phone: (425) 446-5538 FAX: (425) 446-5649 E-mail:

More information

The Effect of Changing the Applied Sequence Using the TVC on the Accuracy of the AC Signal Calibration

The Effect of Changing the Applied Sequence Using the TVC on the Accuracy of the AC Signal Calibration Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com The Effect of Changing the Sequence Using the TVC on the Accuracy of the AC Signal Calibration Rasha S. M. Ali National Institute for Standards

More information

NRC Publications Archive Archives des publications du CNRC

NRC Publications Archive Archives des publications du CNRC NRC Publications Archive Archives des publications du CNRC AC shunt calibrations at NRC Filipski, Peter S.; Boecker, Michael Publisher s version / Version de l'éditeur:, pp. 1-9, 2010-08-25 NRC Publications

More information

EUROMET 557 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS

EUROMET 557 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS EUROMET 557 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS Key comparison Final Report Andre POLETAEFF LNE 29, avenue Roger Hennequin 78197 TRAPPES FRANCE Report on the EUROMET comparison of AC-DC high voltage

More information

Wideband resistive voltage divider for a standard wattmeter

Wideband resistive voltage divider for a standard wattmeter Wideband resistive voltage divider for a standard wattmeter Daniel Slomovitz 1, Leonardo Trigo 1, Gonzalo Aristoy 1, Marcelo Brehm 1 Gregory A. Kyriazis 2 1 Administración Nacional de Usinas y Transmisiones

More information

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard 1. Abstract The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard Authors: Milen Todorakev, Jeff Gust Fluke Calibration. 6920 Seaway Blvd, Everett WA Tel:

More information

30 th meeting of the CCEM March 2017 at BIPM. Activities from CEM Electricity and Magnetism Division

30 th meeting of the CCEM March 2017 at BIPM. Activities from CEM Electricity and Magnetism Division CCEM/17-Report-CEM 30 th meeting of the CCEM 22 24 March 2017 at BIPM Activities from CEM Electricity and Magnetism Division The activities of the Electricity and Magnetism Division are mainly directed

More information

MODEL 5002 PHASE VERIFICATION BRIDGE SET

MODEL 5002 PHASE VERIFICATION BRIDGE SET CLARKE-HESS COMMUNICATION RESEARCH CORPORATION clarke-hess.com MODEL 5002 PHASE VERIFICATION BRIDGE SET TABLE OF CONTENTS WARRANTY i I BASIC ASSEMBLIES I-1 1-1 INTRODUCTION I-1 1-2 BASIC ASSEMBLY AND SPECIFICATIONS

More information

SPEED is one of the quantities to be measured in many

SPEED is one of the quantities to be measured in many 776 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 47, NO. 3, JUNE 1998 A Novel Low-Cost Noncontact Resistive Potentiometric Sensor for the Measurement of Low Speeds Xiujun Li and Gerard C.

More information

Report on the Activities in Electricity and Magnetism within National Institute of Metrology (NIM), China CCEM 2017

Report on the Activities in Electricity and Magnetism within National Institute of Metrology (NIM), China CCEM 2017 Report on the Activities in Electricity and Magnetism within National Institute of Metrology (NIM), China CCEM 2017 RESEARCH PROGRESS DC&LF 1. Joule Balance The new Joule balance has been mounted by the

More information

FINAL REPORT. EUROMET project No Bilateral comparison of DC and AC voltages BEV - NCM. W. Waldmann (BEV, pilot laboratory) P.

FINAL REPORT. EUROMET project No Bilateral comparison of DC and AC voltages BEV - NCM. W. Waldmann (BEV, pilot laboratory) P. FINAL REPORT EUROMET project No. 690 Bilateral comparison of DC and AC voltages BEV - NCM W. Waldmann (BEV, pilot laboratory) P. Aladzhem (NCM) April 006 Euromet690_Final_Report.doc page 1 of 1 1. Introduction

More information

Comparison of IC Conducted Emission Measurement Methods

Comparison of IC Conducted Emission Measurement Methods IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 52, NO. 3, JUNE 2003 839 Comparison of IC Conducted Emission Measurement Methods Franco Fiori, Member, IEEE, and Francesco Musolino, Member, IEEE

More information

CONDUCTIVITY sensors are required in many application

CONDUCTIVITY sensors are required in many application IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 54, NO. 6, DECEMBER 2005 2433 A Low-Cost and Accurate Interface for Four-Electrode Conductivity Sensors Xiujun Li, Senior Member, IEEE, and Gerard

More information

FINAL PUBLISHABLE JRP REPORT

FINAL PUBLISHABLE JRP REPORT FINAL PUBLISHABLE JRP REPORT JRP Contract Number: JRP Short Name: JRP Full Title: T4 J01 Power & Energy The Next Generation of Power and Energy Measurements Period covered (dates): From April 2008 To March

More information

Application of Digital Sampling Method for Voltage Transformer Test Set Calibrations. Hüseyin Çaycı

Application of Digital Sampling Method for Voltage Transformer Test Set Calibrations. Hüseyin Çaycı Application of Digital Sampling Method for Voltage Transformer Test Set Calibrations Hüseyin Çaycı National Metrology Institute of Turkey, TUBITAK UME, P.O.Box:54, 41470, Gebze, Kocaeli, Turkey, phone:

More information

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Christian Suttner*, Stefan Tenbohlen Institute of Power Transmission and High Voltage Technology (IEH), University of

More information

e th2 e th1 e th4 e th3

e th2 e th1 e th4 e th3 Automated reversing switch and monitor for high accuracy voltage standards P. P. Capra, A. Sosso, D. Serazio Istituto Elettrotecnico Nazionale G. Ferraris Strada Delle Cacce, 91 10135 TURIN (Italy) Tel.

More information

CCEM-K9 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS

CCEM-K9 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS CCEM-K9 COMPARISON OF AC-DC HIGH VOLTAGE STANDARDS Key comparison final report Andre POLETAEFF LNE 29, avenue Roger Hennequin 78197 TRAPPES FRANCE Report on the CCEM-K9 comparison of AC-DC high voltage

More information

Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material

Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material Marko Kettunen, Kare-Petri Lätti, Janne-Matti Heinola, Juha-Pekka Ström and Pertti Silventoinen Lappeenranta

More information

AC-DC TRANSFER DIFFERENCE STANDARDS AND CALIBRATIONS AT NRC CANADA

AC-DC TRANSFER DIFFERENCE STANDARDS AND CALIBRATIONS AT NRC CANADA AC-DC TRANSFER DIFFERENCE STANDARDS AND CALIBRATIONS AT NRC CANADA Piotr S. Filipski, Michael Boecker Institute for National Measurement Standards, National Research Council Canada 1200 Montreal Rd. Bldg.

More information

Summary 185. Chapter 4

Summary 185. Chapter 4 Summary This thesis describes the theory, design and realization of precision interface electronics for bridge transducers and thermocouples that require high accuracy, low noise, low drift and simultaneously,

More information

Calibration of 100 MΩ Hamon resistor using current-sensing Wheatstone bridge. Ivan Leniček 1, Roman Malarić 2, Alan Šala 3

Calibration of 100 MΩ Hamon resistor using current-sensing Wheatstone bridge. Ivan Leniček 1, Roman Malarić 2, Alan Šala 3 Calibration of 100 MΩ Hamon resistor using current-sensing Wheatstone bridge Ivan Leniček 1, Roman Malarić 2, Alan Šala 3 1 Faculty of electrical engineering and computing, Unska 3, 10000 Zagreb, Croatia,

More information

TO LIMIT degradation in power quality caused by nonlinear

TO LIMIT degradation in power quality caused by nonlinear 1152 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 6, NOVEMBER 1998 Optimal Current Programming in Three-Phase High-Power-Factor Rectifier Based on Two Boost Converters Predrag Pejović, Member,

More information

A COMPLEX CURRENT RATIO DEVICE FOR THE CALIBRATION OF CURRENT TRANSFORMER TEST SETS

A COMPLEX CURRENT RATIO DEVICE FOR THE CALIBRATION OF CURRENT TRANSFORMER TEST SETS Metrol. Meas. Syst., Vol. XVIII (2011), No. 1, pp. 159-164 METROLOGY AND MEASUREMENT SYSTEMS Index 330930, ISSN 0860-8229 www.metrology.pg.gda.pl A COMPLEX CURRENT RATIO DEVICE FOR THE CALIBRATION OF CURRENT

More information

MEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS

MEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS MEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS Gert RIETVELD Ernest HOUTZAGER Milos ACANSKI Dennis HOOGENBOOM VSL, the Netherlands

More information

Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report

Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report Gregory A. Kyriazis 1, Lucas Di Lillo 2, Daniel Slomovitz 3, Ricardo Iuzzolino 2, Eliana

More information

Comparison of the NIST and NRC Josephson Voltage Standards (SIM.EM.BIPM-K10.b)

Comparison of the NIST and NRC Josephson Voltage Standards (SIM.EM.BIPM-K10.b) Comparison of the NIST and Josephson Voltage Standards (SIM.EM.BIPM-K10.b) Yi-hua Tang National Institute of Standards and Technology (NIST) Gaithersburg, MD 0899, USA Telephone: + (301) 975-4691, email:

More information

INTERNATIONAL OIML R 103 RECOMMENDATION

INTERNATIONAL OIML R 103 RECOMMENDATION INTERNATIONAL OIML R 103 RECOMMENDATION Edition 1992 (E) Measuring instrumentation for human response to vibration (with reference to International Standards 8041 and 5347 of the International Organization

More information

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK Cost-Effective Traceability for Oscilloscope Calibration Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK Abstract The widespread adoption of ISO 9000 has brought an increased

More information

2-3 Calibration of Standard Voltage and Current Generator

2-3 Calibration of Standard Voltage and Current Generator 2-3 Calibration of Standard Voltage and Current Generator Katsumi FUJII, Kojiro SAKAI, Tsutomu SUGIYAMA, Kouichi SEBATA, and Iwao NISHIYAMA This paper describes the calibration method of standard voltage

More information

Design on LVDT Displacement Sensor Based on AD598

Design on LVDT Displacement Sensor Based on AD598 Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Design on LDT Displacement Sensor Based on AD598 Ran LIU, Hui BU North China University of Water Resources and Electric Power, 450045, China

More information

Improving Passive Filter Compensation Performance With Active Techniques

Improving Passive Filter Compensation Performance With Active Techniques IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 50, NO. 1, FEBRUARY 2003 161 Improving Passive Filter Compensation Performance With Active Techniques Darwin Rivas, Luis Morán, Senior Member, IEEE, Juan

More information

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function 328 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 50, NO. 2, APRIL 2003 A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function Sangsun Kim, Member, IEEE, and Prasad

More information

Supplementary Comparison EUROMET.EM.RF-S25 EURAMET Project 819. Comparison of Electrical Field Strength Measurements above 1 GHz.

Supplementary Comparison EUROMET.EM.RF-S25 EURAMET Project 819. Comparison of Electrical Field Strength Measurements above 1 GHz. EURAMET.EM.RF-S25 Final Report page 1 of 120 Supplementary Comparison EUROMET.EM.RF-S25 EURAMET Project 819 Comparison of Electrical Field Strength Measurements above 1 GHz Final Report Karel Dražil Czech

More information

5790A Automated AC Measurement Standard

5790A Automated AC Measurement Standard 5790A Automated AC Measurement Standard Technical Data Accuracy that s easy to use The 5790A is a complete automated ac measurement standard designed for the most demanding calibration applications. It

More information

An improvement for dual channel sampling wattmeter

An improvement for dual channel sampling wattmeter Int. J. Metrol. Qual. Eng. 1, 59 65 (2010) c EDP Sciences 2010 DOI: 10.1051/ijmqe/2010014 An improvement for dual channel sampling wattmeter W.M.S. Wijesinghe 1, and Y.T. Park 2 1 University of Science

More information

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans.   Electronic Measurements & Instrumentation UNIT 2 Q.1) Describe the functioning of standard signal generator Ans. STANDARD SIGNAL GENERATOR A standard signal generator produces known and controllable voltages. It is used as power source for the

More information

A Prototype Wire Position Monitoring System

A Prototype Wire Position Monitoring System LCLS-TN-05-27 A Prototype Wire Position Monitoring System Wei Wang and Zachary Wolf Metrology Department, SLAC 1. INTRODUCTION ¹ The Wire Position Monitoring System (WPM) will track changes in the transverse

More information

HARMONIC contamination, due to the increment of nonlinear

HARMONIC contamination, due to the increment of nonlinear 612 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 44, NO. 5, OCTOBER 1997 A Series Active Power Filter Based on a Sinusoidal Current-Controlled Voltage-Source Inverter Juan W. Dixon, Senior Member,

More information

Realization and traceability of AC power standard at frequency of 50 Hz

Realization and traceability of AC power standard at frequency of 50 Hz Realization and traceability of AC power standard at frequency of 50 Hz Ivan Leniček niversity of Zagreb, Faculty of Electrical Engineering and Computing, nska 3, 0000 Zagreb, Croatia, ivan.lenicek@fer.hr

More information

13 th Asian Physics Olympiad India Experimental Competition Wednesday, 2 nd May 2012

13 th Asian Physics Olympiad India Experimental Competition Wednesday, 2 nd May 2012 13 th Asian Physics Olympiad India Experimental Competition Wednesday, nd May 01 Please first read the following instructions carefully: 1. The time available is ½ hours for each of the two experimental

More information

LFR: flexible, clip-around current probe for use in power measurements

LFR: flexible, clip-around current probe for use in power measurements LFR: flexible, clip-around current probe for use in power measurements These technical notes should be read in conjunction with the LFR short-form datasheet. Power Electronic Measurements Ltd Nottingham

More information

Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences

Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences A. Boglietti, IEEE Member, A. Cavagnino, IEEE Member, T. L. Mthombeni, IEEE Student Member, P. Pillay, IEEE Fellow

More information

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards Fourth LACCEI International Latin American and Caribbean Conference for Engineering and Technology (LACCEI 2006) Breaking Frontiers and Barriers in Engineering: Education, Research and Practice, 21-23

More information

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION David TOPOLANEK Petr TOMAN Michal PTACEK Jaromir DVORAK Brno University of Technology - Czech

More information

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO 16063-41 Dr.-Ing. Uwe Buehn

More information

CHARACTERIZATION and modeling of large-signal

CHARACTERIZATION and modeling of large-signal IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 53, NO. 2, APRIL 2004 341 A Nonlinear Dynamic Model for Performance Analysis of Large-Signal Amplifiers in Communication Systems Domenico Mirri,

More information

TD-100. HAEFELY HIPOTRONICS Technical Document

TD-100. HAEFELY HIPOTRONICS Technical Document HAEFELY HIPOTRONICS Technical Document Breaking the limit of power capacitor resonance frequency with help of PD pulse spectrum to check and setup PD measurement P. Treyer, P. Mraz, U. Hammer, S. Gonzalez

More information

High Efficiency Classes of RF Amplifiers

High Efficiency Classes of RF Amplifiers Rok / Year: Svazek / Volume: Číslo / Number: Jazyk / Language 2018 20 1 EN High Efficiency Classes of RF Amplifiers - Erik Herceg, Tomáš Urbanec urbanec@feec.vutbr.cz, herceg@feec.vutbr.cz Faculty of Electrical

More information

Investigation on the realization of an automated and guarded Hamon GΩ network

Investigation on the realization of an automated and guarded Hamon GΩ network Investigation on the realization of an automated and guarded Hamon 10 10 GΩ network Flavio Galliana 1, Pier Paolo Capra 2, E. Gasparotto 3 1,2 National Institute of Metrological Research, (INRIM) str.

More information

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By: CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL LF METROLOGY Approved By: Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee Date of Approval: 2015-08-26 Date of

More information

OPTICAL LINK TIME TRANSFER BETWEEN IPE AND BEV

OPTICAL LINK TIME TRANSFER BETWEEN IPE AND BEV OPTICAL LINK TIME TRANSFER BETWEEN IPE AND BEV Vladimír Smotlacha CESNET, z.s.p.o Zikova 4, Prague 6, 160 00, The Czech Republic vs@cesnet.cz Alexander Kuna Institute of Photonics and Electronics AS CR,

More information

Traceability for Oscilloscopes and Oscilloscope Calibrators

Traceability for Oscilloscopes and Oscilloscope Calibrators Traceability for Oscilloscopes and Oscilloscope Calibrators in relation to RF Voltage measurements Paul C. A. Roberts Fluke Precision Measurement PCAR Traceability for Scope Cal Mar 2006 1 Introduction

More information

ASPECTS OF REAL-TIME DIGITAL SIMULATIONS OF ELECTRICAL NETWORKS

ASPECTS OF REAL-TIME DIGITAL SIMULATIONS OF ELECTRICAL NETWORKS 23 rd International Conference on Electricity Distribution Lyon, 58 June 25 ASPECTS OF REAL-TIME DIGITAL SIMULATIONS OF ELECTRICAL ABSTRACT Ambrož BOŽIČEK ambroz.bozicek@fe.uni-lj.si Boštjan BLAŽIČ bostjan.blazic@fe.uni-lj.si

More information

High Precision Current Measurement for Power Converters

High Precision Current Measurement for Power Converters High Precision Current Measurement for Power Converters M. Cerqueira Bastos CERN, Geneva, Switzerland Abstract The accurate measurement of power converter currents is essential to controlling and delivering

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Sound level meters Sonomètres OIML R 58 Edition 1998 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Construction and maximum permissible

More information

Wavelet analysis: application to the magneto-inductive testing

Wavelet analysis: application to the magneto-inductive testing 11th European Conference on Non-Destructive Testing (ECNDT 214), October 6-1, 214, Prague, Czech Republic Wavelet analysis: application to the magneto-inductive testing More Info at Open Access Database

More information

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters 9 Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters Drives and Filters Overview. Fast switching of power devices in an inverter causes high dv/dt at the rising

More information

SITE-TO-SITE REPRODUCIBILITY IN CONDUCTED IMMUNITY TESTS ON PC-BASED DATA ACQUISITION SYSTEMS

SITE-TO-SITE REPRODUCIBILITY IN CONDUCTED IMMUNITY TESTS ON PC-BASED DATA ACQUISITION SYSTEMS SITE-TO-SITE REPRODUCIBILITY IN CONDUCTED IMMUNITY TESTS ON PC-BASED DATA ACQUISITION SYSTEMS G.Betta 1, D.Capriglione 1, C.Spataro 2, G.Tinè 3 1 DAEIMI University of Cassino, Via G.Di Biasio 43, 03043

More information

Investigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals

Investigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals Investigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals Shereen M. El-Metwally 1, Mamdouh Halawa 2 1 Department of Systems and Biomedical Engineering, Cairo University,

More information

About the High-Frequency Interferences produced in Systems including PWM and AC Motors

About the High-Frequency Interferences produced in Systems including PWM and AC Motors About the High-Frequency Interferences produced in Systems including PWM and AC Motors ELEONORA DARIE Electrotechnical Department Technical University of Civil Engineering B-dul Pache Protopopescu 66,

More information

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

Analysis of magnetic and electromagnetic field emissions produced by a MRI device Sept. 8-1, 21, Kosice, Slovakia Analysis of magnetic and electromagnetic field emissions produced by a MRI device D. Giordano, M. Borsero, G. Crotti, M. ucca INRIM Istituto Nazionale di Ricerca Metrologica,

More information

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

There is a twenty db improvement in the reflection measurements when the port match errors are removed. ABSTRACT Many improvements have occurred in microwave error correction techniques the past few years. The various error sources which degrade calibration accuracy is better understood. Standards have been

More information

Comparison of the Josephson Voltage Standards of the NIMT and the BIPM

Comparison of the Josephson Voltage Standards of the NIMT and the BIPM Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b) S. Solve, R. Chayramy, M. Stock, S. Pimsut* and N. Rujirat* Bureau International

More information

Comparison of the Josephson Voltage Standards of the LNE and the BIPM

Comparison of the Josephson Voltage Standards of the LNE and the BIPM Comparison of the Josephson Voltage Standards of the LNE and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b) S. Solve and R. Chayramy Bureau International des Poids et Mesures F- 92312

More information

DC Voltage Linearity Measurements and DVM Calibration with Conventional and Programmable Josephson Voltage Standards

DC Voltage Linearity Measurements and DVM Calibration with Conventional and Programmable Josephson Voltage Standards 20th IMEKO TC4 International Symposium and 18th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn Benevento, Italy, September 15-17,

More information

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE Z.Liu, B.T.Phung, T.R.Blackburn and R.E.James School of Electrical Engineering and Telecommuniications University of New South Wales

More information

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses: TUNED AMPLIFIERS 5.1 Introduction: To amplify the selective range of frequencies, the resistive load R C is replaced by a tuned circuit. The tuned circuit is capable of amplifying a signal over a narrow

More information

IMPROVEMENTS IN THE NIST CALIBRATION SERVICE FOR THERMAL TRANSFER STANDARDS

IMPROVEMENTS IN THE NIST CALIBRATION SERVICE FOR THERMAL TRANSFER STANDARDS IMPROVEMENTS IN THE NIST CALIBRATION SERVICE FOR THERMAL TRANSFER STANDARDS Thomas E. Lipe, Joseph R. Kinard, June E. Sims, Yi-hua Tang Quantum Electrical Metrology Division National Institute of Standards

More information

CERN (The European Laboratory for Particle Physics)

CERN (The European Laboratory for Particle Physics) 462 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 48, NO. 2, APRIL 1999 The Measurement Challenge of the LHC Project Gunnar Fernqvist Abstract In 2005, CERN is planning to commission its next

More information

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 16, NO. 5, SEPTEMBER 2001 603 A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

More information

METHODS TO IMPROVE DYNAMIC RESPONSE OF POWER FACTOR PREREGULATORS: AN OVERVIEW

METHODS TO IMPROVE DYNAMIC RESPONSE OF POWER FACTOR PREREGULATORS: AN OVERVIEW METHODS TO IMPROE DYNAMIC RESPONSE OF POWER FACTOR PREREGULATORS: AN OERIEW G. Spiazzi*, P. Mattavelli**, L. Rossetto** *Dept. of Electronics and Informatics, **Dept. of Electrical Engineering University

More information

Moisture measurements with time domain reflectometer (TDR)

Moisture measurements with time domain reflectometer (TDR) 10th International Symposium on District Heating and Cooling September 3-5, 2006 Tuesday, 5 September 2006 Sektion 8 a Heat distribution optimisation of existing solutions Moisture measurements with time

More information

Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report II

Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report II Trilateral South American project: a reference system for measuring electric power up to 100 khz progress report II G. A. Kyriazis 1, L. Di Lillo 2, D. Slomovitz 3, R. Iuzzolino 2, E. Yasuda 2, L. Trigo

More information

COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 khz

COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 khz COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 khz Chen Yi 1, A E Isaev 2, Wang Yuebing 1, A M Enyakov 2, Fei Teng 1 and A N Matveev 2 1

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS

ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS Gerrit de Jong and Erik Kroon NMi Van Swinden Laboratorium P.O. Box 654, 2600 AR Delft,

More information

Politecnico di Torino. Porto Institutional Repository

Politecnico di Torino. Porto Institutional Repository Politecnico di Torino Porto Institutional Repository [Proceeding] Development of a front-end electronics for an innovative monitor chamber for high-intensity charged particle beams Original Citation: Guarachi,

More information

Proposal for instrumentation to calibrate DCCT s up to 24 ka

Proposal for instrumentation to calibrate DCCT s up to 24 ka Klaus. Unser 16. 03.1994 SL-I, CERN Draft: Controlled Circulation personal copy for:... The items marked with this sign ( ) are possibly new ideas which should not be disclosed before they are protected

More information

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet Military University of Technology Kaliskiego 2, 00-908 Warsaw, Poland Tel: +48 22 6839016; Fax: +48 22 6839038 E-mail:

More information

FINAL REPORT. CCEM.RF-K4.CL COMPARISON RF-Voltage measurements up to 1 GHz * Jan P.M. de Vreede 1 (Completed by James Randa 2 )

FINAL REPORT. CCEM.RF-K4.CL COMPARISON RF-Voltage measurements up to 1 GHz * Jan P.M. de Vreede 1 (Completed by James Randa 2 ) FINAL REPORT CCEM.RF-K4.CL COMPARISON RF-Voltage measurements up to 1 GHz * Jan P.M. de Vreede 1 (Completed by James Randa 2 ) 1 Department of Electricity, Radiation and Length Van Swinden Laboratorium

More information

Method for Static and Dynamic Resistance Measurements of HV Circuit Breaker

Method for Static and Dynamic Resistance Measurements of HV Circuit Breaker Method for Static and Dynamic Resistance Measurements of HV Circuit Breaker Zoran Stanisic Megger Sweden AB Stockholm, Sweden Zoran.Stanisic@megger.com Abstract S/DRM testing methods usually use long,

More information

Corona noise on the 400 kv overhead power line - measurements and computer modeling

Corona noise on the 400 kv overhead power line - measurements and computer modeling Corona noise on the 400 kv overhead power line - measurements and computer modeling A. MUJČIĆ, N.SULJANOVIĆ, M. ZAJC, J.F. TASIČ University of Ljubljana, Faculty of Electrical Engineering, Digital Signal

More information