Measuring Instruments. Measuring Instruments

Size: px
Start display at page:

Download "Measuring Instruments. Measuring Instruments"

Transcription

1 Measuring Instruments wa_sg05811 wa_sg

2 Measuring Instruments PHASE OUT TYPE Power Meter KWZ System Rated Current Type Designation Article No. Units per package SG N 40 A KWZ / 60 3N 3N 5 A,CT 63 A KWZ-3PH / 30 KWZ-3PH / 30 KWZ-3PH-63 Power Meter EME System Rated Current Type Designation Article No. Units per package wa_sg N 1N 1N 1N 1N 1N 1N 1N 32 A 32 A, MID cert. 40 A 40 A, MID cert. 80 A 80 A, MID cert. 125 A 125 A, MID cert. EME1P EME1P32MID EME1P EME1P40MID EME1P EME1P80MID EME1P EME1P125MID EME1P125 3N 3N 3N 3N 3N 3N 80 A 80 A, MID cert. 5 A, CT 5 A, CT MID cert. 125 A 125 A, MID cert. EME3P EME3P80MID EME3PCT EME3PCTMID EME3P EME3P125MID Accessories Current Transformer Z-MG/WAK: maximum cable diameter 21 mm Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms Communication modules wa_sg00312 Designation Type Designation Article No. Units per package Communication module Communication module MBUS Communication module with MODBUS EMECLAN EMECMBUS EMECMODB EMECMODB Basic Devices wa_sg05711 System Rated Current Type Designation Article No. Units per package 3N 3N 3N 3N 3N 3N 3N 3N 5 A, CT S0 5 A, CT S0 MID cert. 63 A, S0 63 A, S0 MID cert. 63 A, MODBUS 63 A, S0 MODBUS MID cert. 80 A, S0 MID cert. 80 A, S0 MODBUS MID cert. EME3PCTB EME3PCTBMID EME3P63B EME3P63BMID EME3P63BMODBUS EME3P63BMODBUSMID EME3P80BMID EME3P80BMODBUSMID

3 Multimeter EME3PMMCT5 Communication link Type Designation Article No. Units per package S0 EME3PMMCT LAN Server Modbus/TCP EMELSMODBUS Description Type Designation Article No. Units per package Data Concentrator with Modbus/TCP EMELSMODBUS SG2802 PHASE OUT TYPE Function/Measuring Range Type Designation Article No. Units per package Analogue Ammeter and Voltmeter Z-MG Ammeter/0-10 A Z-MG/AA / 30 Ammeter/0-40 A Z-MG/AA / 30 Ammeter transformer/0-600a, x/5a Z-MG/AA5-WS / 30 Voltmeter/0-250 V Z-MG/VA / 30 Voltmeter/0-500 V Z-MG/VA / 30 SG30012 PHASE OUT TYPE Digital Ammeter and Voltmeter Z-MG Ammeter/0-20 A Z-MG/AD / 30 Ammeter transformer/0-999a, x/5a Z-MG/AD / 30 Voltmeter/0-600 V Z-MG/VD / 30 Ammeter+Voltmeter/0-8kA, x/5a; Z-MG/VD+AD / V Ammeter+Voltmeter/0-8kA, x/5a; 0-600V, 2 programmable contacors Z-MG/VD+AD+S / 30 Accessories Current transformer Z-MG/WAS.., Z-MG/WAK.. Exchangeable scale Z7-MG/WS-.. for Z-MG/AA5-WS 102

4 Digital Ammeter and Voltmeter EM Description Type Designation Article No. Units per package wa_sg00212 Ammeter Voltmeter EMA EMV Accessories Current Transformer Z-MG/WAK: maximum cable diameter 21 mm Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms SG8797 SG8897 PHASE OUT TYPE Function/Ratio/Measuring Range Type Designation Article No. Units per package Current transf. f. cable / 40/5 Current transf. f. cable / 50/5 Current transf. f. cable / 60/5 Current transf. f. cable / 80/5 Current transf. f. busbar / 100/5 Current transf. f. busbar / 150/5 Current transf. f. busbar / 200/5 Current transf. f. busbar / 250/5 Current transf. f. busbar / 300/5 Current transf. f. busbar / 400/5 Current transf. f. busbar / 500/5 Current transf. f. busbar / 600/5 Current transf. f. busbar / 800/5 Current transf. f. busbar / 1000/5 Scale to Z-MG/AA5-WS / 0-50 Scale to Z-MG/AA5-WS / 0-60 Scale to Z-MG/AA5-WS / 0-80 Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Scale to Z-MG/AA5-WS / Z-MG/WAK Z-MG/WAK Z-MG/WAK Z-MG/WAK Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z-MG/WAS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS Z7-MG/WS PHASE OUT TYPE Operating Hours Counter BSZ Readout Rated Voltage Type Designation Article No. Units per package SG digit 5+2digit 230V 50Hz 24V 50Hz BSZ/ / 60 BSZ/ /

5 Operating Hours Counter ASOHC230 wa_sg04411 Readout Rated Voltage Type Designation Article No. Units per package 5+2stellig 230V 50Hz ASOHC PHASE OUT TYPE Pulse Counter Z-IMZ Readout Rated Voltage Type Designation Article No. Units per package SG2702 7digit 7digit 230V 50Hz 24V 50Hz Z-IMZ/ / 60 Z-IMZ/ / 60 Pulse Counter ASPC230 wa_sg05011 Readout Rated Voltage Type Designation Article No. Units per package 7digit 230V 50Hz ASPC

6 Power Meter KWZ Power meter according to IEC/EN for sub-measurement For active energy 3-phase AC types also suitable for uneven load Type KWZ-230: single-phase kwh-meter Type Z-KWZ-3PH: for 4-wire 3-phase AC system with external transducer X/5A; Type Z-MG/WA. Transducer ratios according to table Type Z-KWZ-3PH-25: For 4-wire 3-phase AC system with direct connection Connection diagram KWZ-230 L N 1 4 Output Load KWZ-230 Electrical Rated voltage U n 230 V AC Working range x U n Rated current I b 10A, direct Maximum currenti max 40 A Rated frequency 50/60Hz Overload short time Back-up fuse MCB: C40 40 A gg/gl Sealable no Auxiliary voltage from measurement Power consumption Power loss 2 W Input signal sinusoidal Power factor cosϕ=0.5 inductive to cosϕ=0,8 capacitive Accuracy class 1 Resolution 0.1 kwh LED signal 640 pulse/kwh Own consumption per phase <8 VA DIP adjustment switch for transducer ratios Pulse output rated values 5-48V DC, 50mA Pulse value (jumper) 10 pulse/kwh Switching contact (potential-free) 1 NO Rated peak withstand voltage(1.2/50) µs 5 kv Test voltage 50Hz/1min. 2.5 kv Mechanical Frame size 45 mm Device height 90 mm Device width 35 mm (2MU) Weight 180 g Calibrateable no Display 5+1digit Maximum display reading 99999,9kWh Height of figures 4 mm Mounting quick fastening on DIN rail IEC/EN Degree of protection, built-in IP51 Upper and lower terminals lift terminals Terminal capacity 12mm 2 (2.5mm 2 pulse-outp.) Tightening torque of terminal screws 2 Nm Permitted relative humidity 90% Perm. ambient temperature range -5 to +55 C Flame class acc. to UL 94 V0 Dimensions (mm) KWZ

7 Power Meter KWZ-3PH Power meter according to EN for sub-measurement For active/reactive energy For unbalanced load Programming by front keyboard, 2 keys Sealability front frame and terminal Connection diagram KWZ-3PH KWZ-3PH-63 KWZ-3PH KWZ-3PH-63 Electrical Rated voltage U n / V AC / V AC Working range / V AC / V AC Rated current I b 1 and 5 A 10 A Maximum current I max 6 A 63 A Maximum back-up fuse MCB: B10 or 10A gg/gl MCB: C63 or 63A gg/gl (only voltage pathes) Rated frequency 50 and 60 Hz 50 and 60 Hz Frequency range Hz Hz Power consumption per phase (current path) 0.5 VA (each phase) 4 VA (each phase) Overcurrent short time 20 x I max / 0.5 s 30 x I max / 10 ms Auxiliary voltage from measurement from measurement Input signal sinusoidal sinusoidal Accuracy class 1 1 Metering LED 1 pulse / 0.1 Wh 1 pulse / Wh Pulse output rated values max. 110V AC/DC, 50mA max. 110V AC/DC, 50mA Switching contact (potential-free) Opto coupler Opto coupler S0-Interface according S0-Interface according DIN / EN DIN / EN Pulse frequency (selectable) 1 pulse / 10Wh-100Wh-1kWh-10kWh 1 pulse / 1Wh-10Wh--100Wh1kWh-10kWh optional 1 pulse / 10VArh-100VArh- optional 1 pulse / 10VArh-100VArh- 1kVArh-10kVArh 1kVArh-10kVArh Pulse duration (selectable) ms ms Programmable parameters connection (1-phase, 3-phases connection (3-phases 3- or 4-wire), 3- or 4-wire), external VT and counting, power demand, pulse CT-ratio, power demand, output pulse output Overvoltage category III III Insulation voltage rating (phase - phase) 450 V 300 V Rated impulse withstand voltage (1.2/50) µs 5 kv 5 kv Test voltage Input/pulse-output 2.75 kv 2.75 kv all circuits and earth 4 kv 4 kv Protection class II II Mechanical Frame size 45 mm 45 mm Device height 89 mm 89 mm Device width 71.2 mm 71.2 mm Weight 260 g 260 g Display LCD 8 digit LCD 8 digit Digit height 6 mm 6 mm Maximum display setable ,99 kwh Resolution setable 10 W Measurement display subdivided on 6 pages subdivided on 7 pages Mounting quick fastening on DIN rail IEC/EN Degree of protection, front frame / terminals IP52 / IP20 IP52 / IP20 Upper and lower terminals screw terminals screw terminals Terminal capacity Current terminal rigid cable mm 2 input: rigid cable 1-10mm 2 flexible cable mm 2 flexible cable 1-13mm 2 Voltage terminal rigid cable mm 2 output: rigid cable 1-4mm 2 flexible cable mm 2 flexible cable 1-3mm 2 Permitted relative air humidity suitable for tropical dissipation suitable for tropical dissipation Reference temperature 23 C ±2 C 23 C ±2 C Perm. ambient temperature range -5 to +55 C -5 to +55 C Storage and transportation temperature range -25 to +70 C -25 to +70 C Pollution degree

8 Dimensions (mm) Wiring diagrams KWZ-3PH 1-phase 3-phases 3-wires balanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 4-wires balanced 3-phases 4-wires unbalanced Wiring diagrams KWZ-3PH-63 3-phases 3-wires 3-phases 4-wires 178

9 Energy-meters single-phase A, EME Digital active energy meter with measurement I - U - Hz - PF measurement of active instantaneous power, by IR side set up communication - 1 tariff - 1 S0 Active energy-meters for single-phase alternating current with a, 7 digits counter. These meters have 1 S0 output generating pulses for remote processing of the active energy measurements for 1 tariff. Display LCD For direct connection 32 A and 40 A 7 digits for energy values indication Accuracy class 1 for active energy according to EN (B) Most attractive operating range current (I st... I max ) - for direct connection 32 A and 40 A = A or 40 A The standard versions are designed to be combined with the communication module Active energy register zero setting (not for MID types) Active energy register in T1 import/export Instantaneous power active import/export display Current RMS Voltage RMS Power factor Frequency FW release FW checksum 1 DIN modules wide (18 mm) EME1P32 EME1P32MID EME1P40 EME1P40MID direct connection 32 A direct connection 40 A Data in compliance with EN , EN and EN General characteristics Housing DIN DIN 1 modules 1 modules Mounting EN mm DIN rail DIN rail Depth mm Reference standard active energy - EN , EN EN , EN Operating features Connectivity to single-phase network n wires 2 2 Storage of energy values and configuration FRAM memory - yes yes Supply Rated control supply voltage U n VAC Operating range voltage V Rated frequency f n Hz Rated power dissipation (max.) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous V momentary (1 s) V Current I max continuous A momentary (10 ms) A Display (readouts) Display type LCD n digits 7 (2 decimals) 7 (2 decimals) digit dimensions mm x mm 6.00 x x 3 Active energy: 1 display, 7-digit kwh Instantaneous tariff measurement display, 1-digit - T1 T1 Display period refresh s 1 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN % ±1 (B) ±1 (B) Measuring input Type of connection phase/n - direct direct Operating range voltage phase/n V Current I ref A 5 5 Current I min A Operating range current (I st... I max ) direct connection A Frequency Hz Input waveform - alternating alternating Starting current for energy measurement (I st ) ma Pulse output S0 acc.to EN Pulse output for active energy - yes yes Pulse quantity Imp/kWh Pulse duration ms Required voltage min. (max.) VAC (DC) ±5% ( ) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh

10 EME1P32 EME1P32MID EME1P40 EME1P40MID direct connection 32 A direct connection 40 A Safety acc. to EN Indoor meter - yes yes Degree of pollution Operational voltage V AC voltage test (EN , 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - no yes no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet EMECLAN 10/100 Mbps 10/100 Mbps Modbus RTU, Ascii RS wires EMECMODB up to bps up to bps M-Bus RS wires EMECMBUS up to bps up to bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ1 PZ1 Type cage pulse output blade for slotted screw mm PZ0 PZ0 Terminal capacity main current paths solid wire min. (max.) mm stranded wire with sleeve min. (max.) mm Terminal capacity pulse outlet solid wire min. (max.) mm (2.5) 0.15 (2.5) stranded wire with sleeve min. (max.) mm (4) 0.15 (4) Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 32A or 40A is recommended. 180

11 Energy-meters single-phase 80 A, EME Digital active and reactive energy meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 Active and reaktive (not for MID types) energy-meters for single-phase alternating current with either 1, 7 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 80 A 7 digits for energy values indication Accuracy class 1 for active energy and power according to EN (B) Accuracy class 2 for reactive energy and power according to EN Most attractive operating range current (I st... I max ) for direct connection 80 A = A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 2 DIN modules wide (36 mm) EME1P80 EME1P80MID direct connection 80 A Data in compliance with EN , EN , EN and EN General characteristics Housing DIN DIN 2 modules Mounting EN mm DIN rail Depth mm 70 Reference standard active energy - EN , EN reactive energy - pulse output Operating features Connectivity to single-phase network n wires 2 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous V 276 momentary (1 s) V 300 Current I max continuous A 80 momentary (10 ms) A 2400 Display (readouts) Display type LCD n digits 7 (1 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 7-digit tariffs 1-2 kwh display import or export (arrow) overflow kwh Reactive energy: 1 display, 7-digit tariffs 1-2 kvarh display import or export (arrow) overflow kvarh Instantaneous active power: 1 display, 3-digit W, kw or MW Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar Instantaneous tariff measurement display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN % B Reactive energy and power acc.to EN % 2 Measuring input Type of connection phase/n - direct Operating range voltage phase/n V Current I ref A 15 Current I min A 0.75 Operating range current (I st... I max ) direct connection A Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma

12 EME1P80 EME1P80MID direct connection 80 A Pulse output S0 acc.to EN Pulse output for active and reactive energy T1 and T2 yes Pulse quantity Imp/kWh 1000 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN , 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet EMECLAN 10/100 Mbps Modbus RTU, Ascii RS wires EMECMODB up to bps M-Bus RS wires EMECMBUS up to bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm (35) stranded wire with sleeve min. (max.) mm (35) Terminal capacity pulse outlet solid wire min. (max.) mm (2.5) stranded wire with sleeve min. (max.) mm (1.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 80A is recommended. 182

13 Energy-meters single-phase 125 A, EME Digital active and reactive energy meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs Active energy-meters for single-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 125 A 8 digits for energy values indication Accuracy class 1 for active energy and power according to EN (B) Accuracy class 2 for reactive energy and power according to EN Most attractive operating range current (I st... I max ) for direct connection 125 A = A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display Sealable terminal covers 3 DIN modules wide (52 mm) EME1P125 EME1P125MID direct connection 125 A Data in compliance with EN , EN , EN and EN General characteristics Housing DIN DIN 3 modules Mounting EN mm DIN rail Depth mm 70 Reference standard active energy - EN , EN reactive energy - pulse output Operating features Connectivity to single-phase network n wires 2 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous V 276 momentary (1 s) V 300 Current I max continuous A 125 momentary (10 ms) A 3750 Display (readouts) Display type LCD n digits 8 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 8 digit tariffs 2 Wh display import or export (arrow) overflow MWh Reactive energy: 1 display, 8 digit tariffs 2 varh display import or export (arrow) overflow Mvarh Instantaneous active power: 1 display, 3-digit W, kw or MW Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar Instantaneous tariff measurement display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN % B Reactive energy and power acc.to EN % 2 Measuring input Type of connection phase/n - direct Operating range voltage phase/n V Current I ref A 5 Current I min A 0.25 Operating range current (I st... I max ) direct connection A Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma

14 EME1P125 EME1P125MID direct connection 125 A Pulse output S0 acc.to EN Pulse output for active and reactive energy T1 and T2 yes Pulse quantity Imp/kWh 1000 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN , 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet EMECLAN 10/100 Mbps Modbus RTU, Ascii RS wires EMECMODB up to bps M-Bus RS wires EMECMBUS up to bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm (50) stranded wire with sleeve min. (max.) mm (50) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 125A is recommended. 184

15 Energy-meters three-phase, transformer 5 A, direct 80 A, EME Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power). Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 80 A, or for transformer.../5 A For transformer primary current of 5 A to /5 A. Input is in 5 A increments 8 digits - 8 display for energy values indication Detection of connection errors (phase transposition) Accuracy class 1 for active energy and power according to EN (B) Accuracy class 2 for reactive energy and power according to EN Most attractive operating range current (I st... I max ), for direct connection 80 A = A, for connection by CT.../5 A = A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 4 DIN modules wide (72 mm) EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till /5 A Data in compliance with EN , EN , EN and EN General characteristics Housing DIN DIN 4 modules 4 modules Mounting EN mm DIN rail DIN rail Depth mm Reference standard active energy - EN EN pulse output EN EN Operating features Connectivity to single/three-phase network n wires Storage of energy values and configuration digital display (EEPROM) - yes yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 T1 and T2 Supply Rated control supply voltage U n VAC Operating range voltage V Rated frequency f n Hz Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V second: phase/phase V continuous; phase/n V second: phase/n V Current I max continuous A 80 6 momentary (0,5 s) A momentary (10 ms) A Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err PHASE Err Display type LCD n digits 8 (2 decimal) 8 (2 decimal) digit dimensions mm x mm 6.00 x x 3 Active energy: 1 display, 8 digit tariffs 2 Wh display import or export (arrow) overflow MWh Reactive energy: 1 display, 8-digit tariffs 2 varh display import or export (arrow) overflow Mvarh Instantaneous active power: 1 display, 3-digit W, kw or MW Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 T1 or T2 Transformer primary current A Display period refresh s 1 1 Measuring accuracy Active energy and power acc.to EN class 1 B B Reactive energy and power acc.to EN class

16 EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till /5 A Measuring input Type of connection direct transformer.../5 A Voltage U n phase/phase V phase/n V Operating range voltage phase/phase V phase/n V Current I ref A 5 - Current I n A - 5 Current I min A Operating range current (I st... I max ) direct connection A transformer connection (CT) A Transformer current primary current of the transformer A smallest input step adjustment - in 5 A steps A - 5 Frequency Hz Input waveform - sinusoidal sinusoidal Starting current for energy measurement (I st ) ma 15 3 Pulse output SO acc.to EN Pulse output for act. and react. energy T1 and T2 yes yes Quantity pulse output for direct connection 80 A Imp/kWh depending on the transf. factor. Imp/kWh Pulse duration ms 30 ±2 30 ±2 Required voltage min. (max.) VAC (DC) ±5% ( ) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma Permissible current pulse OFF (leakage current max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh Safety acc. to EN Indoor meter - yes yes Degree of pollution Operational voltage V AC voltage test (EN , 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - yes no no yes Adaptor for Communication Plug-and-play technology - LAN (TCP/IP) interface Ethernet EMECLAN 10/100 Mbps 10/100 Mbps Modbus RTU, Ascii interface RS wires EMECMODB up to bps up to bps M-Bus interface RS wires EMECMBUS up to bps up to bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 PZ1 Type cage pulse output blade for slotted screw mm 0.8 x x 3.5 Terminal capacity main current paths solid wire min. (max.) mm (35) 1 (4) stranded wire with sleeve min. (max.) mm (35) 1 (4) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) 1 (4) 186

17 EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till /5 A Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Direct connection 80 A Dimensions (mm) Connection diagrams A Miniature Circuit Breaker of 80A is recommended. Wire N needs to be connected to the meter. 187

18 Connection through CT.../5 A till /5 A Dimensions (mm) Connection diagrams Wire N needs to be connected to the meter. Instructions for the connection of transformer counters A Miniature Circuit Breaker of 6A is recommended. Current transformers must not be operated with open terminals since dangerous high voltages might occur which may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload. 188

19 Energy-meters three-phase 125 A, EME Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power). Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 125 A 8 digits - 8 display for energy values indication Detection of connection errors (phase transposition) Accuracy class 1 for active energy and power according to EN (B) Accuracy class 2 for reactive energy and power according to EN Most attractive operating range current (I st... I max ) for direct connection 125 A = A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 6 DIN modules wide (108 mm) EME3P125 EME3P125MID direct connection 125 A Data in compliance with EN , EN , EN and EN General characteristics Housing DIN DIN 6 modules Mounting EN mm DIN rail Depth mm 70 Reference standard active energy - EN reactive energy - pulse output EN Operating features Connectivity to single/three-phase network n wires 2-4 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V second: phase/phase V 800 continuous; phase/n V second: phase/n V 300 Current I max continuous A 125 momentary (10 ms) A 3750 Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err Display type LCD n digits 8 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 8 digit tariffs 2 Wh display import or export (arrow) overflow MWh Reactive energy: 1 display, 8 digit tariffs 2 varh display import or export (arrow) overflow Mvarh Instantaneous active power: 1 display, 3-digit W, kw or MW Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar Instantaneous tariff measurement display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy Active energy and poweracc.to EN % B Reactive energy and power acc.to EN % 2 Measuring input Type of connection direct Voltage U n phase/phase V 400 phase/n V 230 Operating range voltage phase/phase V phase/n V

20 EME3P125 EME3P125MID direct connection 125 A Measuring input Current I ref A 5 Current I min A 0.25 Operating range current (I st... I max ) direct connection A Frequency Hz 50 ±2% Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 20 Pulse output S0 acc.to EN Pulse output for active and reactive energy T1 and T2 yes Quantity pulse output Imp/kWh 500 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN , 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN (TCP/IP) interface Ethernet EMECLAN 10/100 Mbps Modbus RTU, Ascii interface RS wires EMECMODB up to bps M-Bus interface RS wires ENECMBUS up to bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm (50) stranded wire with sleeve min. (max.) mm (50) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 190

21 Dimensions (mm) Connection diagrams A Miniature Circuit Breaker of 125A is recommended. Wire N needs to be connected to the meter. 191

22 LAN-TCP/IP interface EMECLAN Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for LAN-TCP/IP connection for energy, power, V, I, cosϕ, frequency Data transfer speed LAN limited Mbit/s 100 HW interface RJ 45 connector SW protocol TCP/IP Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECLAN Data in compliance with IEC 60950, EN , EN and EN General characteristics Housing DIN DIN 1 module Mounting EN mm DIN rail Depth mm 70 Power supply Auxiliary voltage rating U n VAC 230 Auxiliary power rating W 1.5 Auxiliary voltage range VAC x U n Frequency rating Hz 50/60 Frequency range Hz Operating features System start - automatic at connection of auxiliary power LAN Server data addressing - by means of it IP address Data transfer speed LAN limited Mbit/s 100 User interface for setup and management Web browser W3C HTML 4.01 compliant Suitable for both single-phase and three-phase energy meters yes LAN Interface HW interface - RJ 45 connector SW protocol - TCP/IP Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC Degree pollution - 2 Overvoltage category - II Working voltage V 300 Clearance mm 4 Creepage distance mm 4 Test voltage impulse (1,2/50 µs) peak value on AC power supply kv 4 50 Hz 1 min kv 4 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm (2.5) stranded wire with sleeve min. (max.) mm (4) Environmental conditions Operating temperature C Limit temperature of transportation and storage C Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC II Degree of protection housing when mounted in front IP20 Dimensions (mm) 192

23 M-Bus interface EMECMBUS Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for M-Bus connection for energy, power, V, I, cosϕ, frequency M-Bus according to EN1434 Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECMBUS Data in compliance with EN , IEC 60950, EN , EN and EN General characteristics Housing DIN DIN 1 module Mounting EN mm DIN rail Depth mm 70 Power supply Power supply - through bus connection Operating features Suitable for both single-phase and three-phase energy meters yes M-bus interface HW interface - 2 screw clamps SW protocol - M-Bus according to EN1434 Baudrate Baud Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC Degree pollution - 2 Overvoltage category - II Working voltage V Clearance in equipment mm 1.5 on PCB (not coated) mm 1.5 Creepage distance mm 2.1 Test voltage impulse (1,2/50 µs) peak value kv Hz 1 min kv 1.35 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm (2.5) stranded wire with sleeve min. (max.) mm (4) Environmental conditions Operating temperature C Limit temperature of transportation and storage C Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC II Degree of protection housing when mounted in front IP20 Dimensions (mm) 193

24 Modbus interface RTU and Ascii EMECMODB Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for Modbus RTU and Ascii connection for energy, power, V, I, cosϕ, frequency Protocols Modbus Ascii - Modbus RTU Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECMODB Data in compliance with IEC 60950, EN , EN and EN General characteristics Housing DIN DIN 1 module Mounting EN mm DIN rail Depth mm 70 Power supply Auxiliary voltage rating U n VAC 230 Auxiliary power rating W 10 Auxiliary voltage range VAC x U n Frequency rating Hz 50/60 Frequency range Hz Operating features Protocol selectable by software - Modbus RTU or Ascii Suitable for both single-phase and three-phase energy meters yes Modbus interface HW interface RS-485 terminals n 3 (+/-, cable shield) Input resistance UL (kω) 1 (12) Termination resistance Ω 80 SW protocol SW selectable - Modbus Ascii - Modbus RTU Data transfer speed SW selectable baud default Parity - none/even - default: none Addressing - 1 to 247 Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC Degree pollution - 2 Overvoltage category - II Working voltage V 300 Clearance mm 4 Creepage distance mm 4 Test voltage impulse (1,2/50 µs) peak value on AC power supply kv 2.5 on telecommunication network kv Hz 1 min kv 2.5 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm (2.5) stranded wire with sleeve min. (max.) mm (4) Environmental conditions Operating temperature C Limit temperature of transportation and storage C Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC II Degree of protection housing when mounted in front IP20 Dimensions (mm) 194

25 BASIC Energy-meters three-phase, transformer 5 A, EME Active energy-meters for three-phase alternating current with either 2, 9 digits digital counters. These meters have 1 S0 output generating pulses for remote processing of the instantaneous energy active measurements for 2 tariffs. Three-phase digital active energy-meter with connection by CT.../5 A, up to /5 A (6) A - 2 tariffs - 2 S0 For transformer.../5 A For transformer primary current of 5 A to /5 A. Input is in 5 A increments 9 digits - 4 display for energy values indication Detection of connection errors (phase transposition and phase missing) Accuracy class 1 for active energy and power according to EN (B) Most attractive operating range current (I st... I max ), for connection by CT.../5 A = A Energy register zero setting (not for MID types) Energy register for import and export Sealable terminal covers 4 DIN modules wide (72 mm) EME3PCTB EME3PCTBMID CT connection till /5 A Data in compliance with EN , EN and EN General characteristics Housing DIN DIN 4 modules Mounting EN mm DIN rail Depth mm 70 Reference standard active energy - EN pulse output EN Operating features Connectivity to three-phase network n wires 4 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V Rated frequency f n Hz 50 Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V second: phase/phase V 800 continuous; phase/n V second: phase/n V 300 Current I max continuous A 6 momentary (0,5 s) A 120 momentary (10 ms) A - Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err Display type LCD n digits 9 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 9 digit - 2 tariffs min. measuring energy kwh display import or export (arrow) max. measuring overflow kwh Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 Transformer primary current A Display period refresh s 1 Measuring accuracy Active energy acc.to EN class 1 B Measuring input Type of connection transformer.../5 A Voltage U n phase/phase V 400 phase/n V 230 Operating range voltage phase/phase V phase/n V Current I ref A - Current I n A 5 Current I min A 0.05 Operating range current (I st... I max ) direct connection A - transformer connection (CT) A

26 EME3PCTB EME3PCTBMID CT connection till /5 A Measuring input Transformer current primary current of the transformer A smallest input step adjustment in 5 A steps A 5 Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 3 Pulse output S0 acc.to EN Pulse output for active and reactive energy T1 and T2 yes Quantity pulse output for direct connection 63 A Imp/kWh - depending on the transf. factor Imp/kWh Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh Safety acc. to EN Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN , 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ1 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (4) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (4) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 196

27 Connection through CT.../5 A till /5 A Connection diagrams Dimensions (mm) Wire N needs to be connected to the meter. Instructions for the connection of transformer counters A Miniature Circuit Breaker of 6A is recommended. Current transformers must not be operated with open terminals since dangerous high voltages might occur which may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload. 197

28 BASIC Energy-meters three-phase, direct 63 A, EME Active energy-meters for three-phase alternating current with either 2, 9 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active measurements for 2 tariffs. Three-phase digital active energy-meter with direct connection (63) A - 2 tariffs - 2 S0 For direct connection 63 A 9 digits - display for 4 energy values indication Detection of connection errors (phase transposition and phase missing) Accuracy class 1 for active energy and power according to EN (B) Most attractive operating range current (I st... I max ), for direct connection 63 A = A Energy register zero setting (not for MID types) Energy register for import and export Sealable terminal covers 4 DIN modules wide (72 mm) EME3P63B EME3P63BMID direct connection 63 A direct connection 63 A Data in compliance with EN , EN and EN General characteristics Housing DIN DIN 4 modules 4 modules Mounting EN mm DIN rail DIN rail Depth mm Reference standard active energy - EN EN pulse output EN EN Operating features Connectivity to three-phase network n wires 4 4 Storage of energy values and configuration digital display (EEPROM) - yes yes Display tariffs identifier for active energy n 2 T1 and T2 T1 and T2 Supply Rated control supply voltage U n VAC Operating range voltage V Rated frequency f n Hz Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V second: phase/phase V continuous; phase/n V second: phase/n V Current I max continuous A momentary (0,5 s) A - - momentary (10 ms) A Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err PHASE Err Display type LCD n digits 9 (2 decimal) 9 (2 decimal) digit dimensions mm x mm 6.00 x x 3 Active energy: 1 display, 9 digit - 2 tariffs min. measuring energy kwh display import or export (arrow) max. measuring overflow kwh Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 T1 or T2 Transformer primary current A - - Display period refresh s 1 1 Measuring accuracy Active energy acc.to EN class 1 B B Measuring input Type of connection direct direct Voltage U n phase/phase V phase/n V Operating range voltage phase/phase V phase/n V Current I ref A 5 5 Current I n A - - Current I min A Operating range current (I st... I max ) direct connection A transformer connection (CT) A

29 Measuring input Transformer current EME3P63B direct connection 63 A primary current of the transformer A - - smallest input step adjustment - - A - - EME3P63BMID direct connection 63 A Frequency Hz Input waveform - sinusoidal sinusoidal Starting current for energy measurement (I st ) ma Pulse output S0 acc.to EN Pulse output for active and reactive energy T1 and T2 yes yes Quantity pulse output for direct connection 63 A Imp/kWh depending on the transf. factor Imp/kWh - - Pulse duration ms 30 ±2 ms 30 ±2 ms Required voltage min. (max.) VAC (DC) ±5% ( ) ±5% ( ) Permissible current pulse ON (max. 230 V AC/DC) ma Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh Safety acc. to EN Indoor meter - yes yes Degree of pollution Operational voltage V AC voltage test (EN , 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - yes yes Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 PZ2 Type cage pulse output blade for slotted screw mm 0.8 x x 3.5 Terminal capacity main current paths solid wire min. (max.) mm (35) 1.5 (35) stranded wire with sleeve min. (max.) mm (35) 1.5 (35) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) 1 (2.5) Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C Limit temperature of transportation and storage C Relative humidity (not condensation) % Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 199

Power-meters three-phase

Power-meters three-phase ADP3-0C Digital display symbols for all three phases: I - U-PF -Hz -P- Q-S, active energy export/import by IR side set up communication Power-meters three-phase Direct connection 0 A Application The new

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 D 95448 Bayreuth Fon +49 (0) 921 1512678-0 Fa +49 (0) 921 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de DIN rail 35mm KE-N80

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

EM-72 Electricity Meters for Current Transformers

EM-72 Electricity Meters for Current Transformers Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the

More information

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Analyzer Type EM210 MID Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters. cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Energy Management Energy Meter Type EM340

Energy Management Energy Meter Type EM340 Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order

More information

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM112 Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter GM3T E GM3T-RS485 E Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320

More information

Energy Management Energy Analyzer Type EM111

Energy Management Energy Analyzer Type EM111 Energy Management Energy Analyzer Type EM111 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM21 72R Retro-Fit Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class

More information

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)

More information

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207 Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207 o 7 digits electromechanical register o Up to 2 registers

More information

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485 cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase

More information

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...

More information

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet INSTRUCTION MANUAL COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet EN countis e27 countis e28 - mid www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM111 Energy Management Energy Meter Type EM111 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter

More information

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM112 Energy Management Energy Meter Type EM112 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter

More information

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM210 Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)

More information

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus speicher MID energy meter ECSEM series Emax 2 Tariffs GridVis 7 Tariffs 8 Tariffs 14 Tariffs 0,2 kwh Class 0,5 kwh Class 1,0 kwh Class Pulse output Tarife 2 tariffs Messgenauigkeit Modbus MID M-Bus eratureingang

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

MBus Interface for Energy and Power meters AEM and APM

MBus Interface for Energy and Power meters AEM and APM DESCRIPTION OF OPTION for Energy and Power meters AEM and APM Technical reference Document no.: 4189320045B Table of contents 1. ABOUT THIS DOCUMENT... 4 GENERAL PURPOSE... 4 INTENDED USERS... 4 CONTENTS/OVERALL

More information

Energy Management Energy Analyzer Type EM270-72D

Energy Management Energy Analyzer Type EM270-72D Energy Management Energy Analyzer Type EM270-72D RS485 dual port for daisy chain connection (optional) 2 programmable pulsating outputs (optional) Easy connections management (selectable) disabled by default

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual.   en/countis-e2x Instruction manual COUNTIS E23/E24 Three-phase energy meter Direct - 80 A MODBUS COUNTIS E23 COUNTIS E24 - MID www.socomec.com/ en/countis-e2x Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

3 phase energy meters with integrated Serial Modbus interface

3 phase energy meters with integrated Serial Modbus interface Data sheet www.sbc-support.com 3 phase energy meters with integrated Serial Modbus interface Energy meters with an integrated Serial RS-485 Modbus interface allow direct reading of all relevant data, such

More information

Contents. Introduction and description Package contents Device identification PM Options... 80

Contents. Introduction and description Package contents Device identification PM Options... 80 Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections

More information

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM280-72D Energy Management Energy Analyzer Type EM280-72D Equivalent to Class 1 (kwh) of EN62053-21 (EM280 base only) Equivalent to Class 2 (kvarh) of EN62053-23 (EM280 base only) Virtual meter (sum of two 3-phase

More information

Single phase energy meter with Serial Modbus interface

Single phase energy meter with Serial Modbus interface Data sheet www.sbc-support.com Single phase energy meter with Serial Modbus interface Energy meters with a Serial RS-485 Modbus interface allow direct reading of all relevant data, such as energy (total

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

GSC57 Rel of 257/10/05

GSC57 Rel of 257/10/05 Integrated meter for test verify and Power Quality analysis Pag 1 of 7 1. ELECTRICAL SPECIFICATIONS VERIFY TESTS Accuracy is indicated as ± (% readings + no. of digits) at 23 C ± 5 C, con relative humidity

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display:

More information

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN Energy Management Energy Meter Type EM33 DIN Easy connections management Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X):

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply

More information

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202 DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144 Panel Meters, Accessories Moving Coil, DQ Moving Coil, VDQ Moving Iron, EQ (240 ) (90 ) Measurement of DC currents and DC voltages. Measurement of AC currents and AC voltages. Measurement of AC currents

More information

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet Smart Energy & Power Quality Solutions Power Quality Analyser Data sheet Dok.-Nr. 2.054.030.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view Cut-out size: 92 +0,8 mm x 92 +0,8 mm. All

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110 Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit

More information

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft Energy Management Power Analyzer ype WM-DI Basic Version Optional dual pulse output Alarms (visual only) V L, An Optional galvanically insulated measuring inputs Product Description ype Selection Range

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

M.3. Electrical measurement and control. Electrical energy meters for partial consumption M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

UPM209 1/5A CT, 80A Multifunction three-phase meter

UPM209 1/5A CT, 80A Multifunction three-phase meter 1/5A CT, 80A Multifunction three-phase meter 4 DIN modules compact version Fully bi-directional four quadrants measurements for all energies and powers Main electrical parameters measured and displayed

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

Transformers, Power Supply Units and Socket Outlets

Transformers, Power Supply Units and Socket Outlets Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product

More information

Measurement and control. Digital instruments and measuring transducers

Measurement and control. Digital instruments and measuring transducers Measurement and control Digital instruments and measuring transducers M.2 - Digital instruments and measuring transducers Introduction...M2-3 Product selection table...m2-5 DC Series Digital indicator

More information

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DM-III Multitest & DM-III Multitest F Power Quality Recorders DM-III Multitest & DM-III Multitest F Power Quality Recorders CAT 600V TRUE RMSz Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to

More information

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5. Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics

More information

METRAClip87 and 88 Clamp Multimeters

METRAClip87 and 88 Clamp Multimeters 3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V

More information

Universal measuring transducer

Universal measuring transducer Universal measuring transducer EM4000 Compact housing High accuracy Full galvanic separation MODbus (RS232/RS485) 3 Analogue + 1 Pulse output Direct voltagemeasurement up to 690V 48 hour service EXW ELEQ

More information

Side view View from below Rear view

Side view View from below Rear view Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4

More information

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006 PRI Ltd. 9600-3004-2 Issue C Information contained within this document is subject to change without notice and does not represent

More information