Real-time pulse length measurement of few-cycle laser pulses using above-threshold ionization

Size: px
Start display at page:

Download "Real-time pulse length measurement of few-cycle laser pulses using above-threshold ionization"

Transcription

1 Real-time pulse length measurement of few-cycle laser pulses using above-threshold ionization A. M. Sayler, 1,2 Tim Rathje, 1,2 W. Müller, 1 Ch. Kürbis, 1 Klaus Rühle, 1 Gero Stibenz, 3 and G. G. Paulus 1,2,4, 1 Institut für Optik und Quantenelektronik, Max-Wien-Platz 1, Jena, Germany 2 Helmholtz Institut Jena, Max-Wien-Platz 1, Jena, Germany 3 APE GmbH, Plauener Str , Berlin, Germany 4 Department of Physics, Texas A&M University, College Station, Texas 77843, USA gerhard.paulus@uni-jena.de Abstract: The pulse lengths of intense few-cycle (4 10 fs) laser pulses at 790 nm are determined in real-time using a stereographic above-threshold ionization (ATI) measurement of Xe, i.e. the same apparatus recently shown to provide a precise, real-time, every-single-shot, carrier-envelope phase measurement of ultrashort laser pulses. The pulse length is calibrated using spectral-phase interferometry for direct electric-field reconstruction (SPIDER) and roughly agrees with calculations done using quantitative rescattering theory (QRS). This stereo-ati technique provides the information necessary to characterize the waveform of every pulse in a khz pulse train, within the Gaussian pulse approximation, and relies upon no theoretical assumptions. Moreover, the real-time display is a highly effective tool for tuning and monitoring ultrashort pulse characteristics Optical Society of America OCIS codes: Ultrafast measurements; Strong field laser physics; Ultrafast technology; Multiphoton processes; Femtosecond phenomena. References and links 1. A. Baltuška, T. Udem, M. Uiberacker, M. Hentschel, E. Goulielmakis, C. Gohle, R. Holzwarth, V. Yakoviev, A. Scrinzi, T. Hänsch, and F. Krausz, Attosecond control of electronic processes by intense light fields, Nature 421, (2003). 2. I. P. Christov, M. M. Murnane, and H. C. Kapteyn, High-harmonic generation of attosecond pulses in the singlecycle regime, Phys. Rev. Lett. 78, (1997). 3. P. B. Corkum and F. Krausz, Attosecond science, Nat. Phys. 3, (2007). 4. R. Holzwarth, T. Udem, T. W. Hänsch, J. C. Knight, W. J. Wadsworth, and P. S. J. Russell, Optical frequency synthesizer for precision spectroscopy, Phys. Rev. Lett. 85, (2000). 5. M. Kakehata, H. Takada, Y. Kobayashi, K. Torizuka, Y. Fujihira, T. Homma, and H. Takahashi, Single-shot measurement of carrier-envelope phase changes by spectral interferometry, Opt. Lett. 26, (2001). 6. A. Baltuška, M. Uiberacker, E. Goulielmakis, R. Kienberger, V. S. Yakovlev, T. Udem, T. W. Hänsch, and F. Krausz, Phase-controlled amplification of few-cycle laser pulses, IEEE J. Sel. Top. Quantum Electron. 9, (2003) 7. C. A. Haworth, L. E. Chipperfield, J. S. Robinson, P. L. Knight, J. P. Marangos, and J. W. G. Tisch, Half-cycle cutoffs in harmonic spectra and robust carrier-envelope phase retrieval, Nat. Phys. 3, (2007). 8. T. M. Fortier, P. A. Roos, D. J. Jones, S. T. Cundiff, R. D. R. Bhat, and J. E. Sipe, Carrier-envelope phasecontrolled quantum interference of injected photocurrents in semiconductors, Phys. Rev. Lett. 92, (2004). 9. R. Trebino, K. W. Delong, D. N. Fittinghoff, J. N. Sweetster, M. A. Krumbugel, and B. A. Richman, Measuring ultrashort laser pulses in the time-frequency domain using frequency-resolved optical gating Rev. Sci. Instrum. 68, (1997). (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4464

2 10. D. J. Kane, Recent progress toward real-time measurement of ultrashort laser pulses, IEEE J. Quantum Electron. 35, (1999). 11. C. Iaconis and I. A. Walmsley, Self-referencing spectral interferometry for measuring ultrashort optical pulses, IEEE J. Quantum Electron 35, (1999). 12. G. Stibenz and G. Steinmeyer, Optimizing spectral phase interferometry for direct electric-field reconstruction, Rev. Sci. Instr. 77, (2006). 13. R. Kienberger, E. Goulielmakis, M. Uiberacker, A. Baltuška, V. Yakovlev, F. Bammer, A. Scrinzi, T. Westerwalbesloh, U. Kleineberg, U. Heinzmann, M. Drescher, and F. Krausz, Atomic transient recorder, Nature 427, (2004). 14. J. Itatani, F. Quéré, G. L. Yudin, M. Y. Ivanov, F. Krausz, and P. B. Corkum, Attosecond streak camera, Phys. Rev. Lett. 88, (2002). 15. M. Drescher, M. Hentschel, R. Kienberger, M. Uiberacker, V. Yakovlev, A. Scrinizi, T. Westerwalbesloh, U. Kleineberg, U. Heinzmann, and F. Krausz, Time-resolved atomic inner-shell spectroscopy, Nature 419, (2002). 16. E. Goulielmakis, M. Uiberacker, R. Kienberger, A. Baltuška, V. Yakovlev, A. Scrinzi, T. Westerwalbesloh, U. Kleineberg, U. Heinzmann, M. Drescher, and F. Krausz, Direct measurement of light waves, Science 305, (2004). 17. E. Goulielmakis, M. Schultze, M. Hofstetter, V. S. Yakovlev, J. Gagnon, M. Uiberacker, L. A. Aquila, E. M. Gullikson, D. T. Attwood, R. Kienberger, F. Krausz, and U. Kleineberg, Single-cycle nonlinear optics, Science 320, (2008). 18. V. S. Yakovlev, F. Bammer, and A. Scrinzi, Attosecond streaking measurements, J. Mod. Opt. 52, (2005). 19. M. F. Kling, J. Rauschenberger, A. J. Verhoef, E. Hasović, T. Uphues, D. B. Milošević, H. G. Muller, and M. J. J. Vrakking, Imaging of carrier-envelope phase effects in bovethreshold ionization with intense few-cycle laser fields, New J. Phys. 10, (2008). 20. S. Micheau, Zhangjin Chen, A. T. Le, J. Rauschenberger, M. F. Kling, C. D. Lin, Accurate retrieval of target structures and laser parameters of few-cycle pulses from photoelectron momentum spectra, Phys. Rev. Lett. 102, (2009). 21. A. M. Sayler, T. Rathje, W. Müller, Klaus Rühle, R. Kienberger, and G. G. Paulus, Precise, real-time, everysingle-shot, carrier-envelope phase measurement of ultrashort laser pulses, Opt. Lett. 36, 1 3 (2011). 22. N. G. Johnson, O. Herrwerth, A. Wirth, S. De, I. Ben-Itzhak, M. Lezius, F. Krausz, B. Bergues, M. F. Kling, A. Senftleben, C. D. Schröter, R. Moshammer, J. Ullrich, K. J. Betsch, R. R. Jones, A. M. Sayler, T. Rathje, K. Rühle, W. Müller, and G. G. Paulus, Single-shot carrier-envelope-phase tagged ion momentum imaging of non-sequential double ionization of argon in intense 4-fs laser fields, Phys. Rev. A 83, (2011). 23. G. G. Paulus, A. M. Sayler, T. Rathje, and W. Müller, Apparatus for a fast phase measurement of few-cycle pulses, German Patent Pending, (May 5, 2010). 24. T. Wittmann, B. Horvath, W. Helml, M. G. Schatzel, X. Gu, A. L. Cavalieri, G. G. Paulus, and R. Kienberger, Single-shot carrier-envelope phase measurement of fewcycle laser pulses, Nat. Phys. 5, (2009). 25. Z. Chen, T. Wittmann, B. Horvath, and C. D. Lin, Complete real-time temporal waveform characterization of single-shot few-cycle laser pulses, Phys. Rev. A 80, (2009). 26. Z. Chen, A. T. Le, T. Morishita, and C. D. Lin, Quantitative rescattering theory for laser-induced high-energy plateau photoelectron spectra, Phys. Rev. A 79, (2009). 27. G. G. Paulus, F. Lindner, H. Walther, A. Baltuška, E. Goulielmakis, M. Lezius, and F. Krausz, Measurement of the phase of few-cycle laser pulses, Phys. Rev. Lett. 91, (2003). 28. G. G. Paulus, F. Grasbon, H. Walther, P. Villoresi, M. Nisoli, S. Stagira, E. Priori, and S. De Silvestri, Absolutephase phenomena in photoionization with few-cycle laser pulses, Nature 414, (2001). 29. D. J. Jones, S. A. Diddams, J. K. Ranka, A. Stentz, R. S. Windeler, J. L. Hall, and S. T. Cundiff, Carrier-envelope phase control of femtosecond mode-locked lasers and direct optical frequency synthesis, Science 288, (2000). 1. Introduction The time-dependent electric field of a laser pulse dictates the dynamics of strong-field laser matter interactions. Therefore, characterization of the waveform is critical for the understanding and control of these interactions. Moreover, the precise determination of these parameters is especially important for applications in the few-cycle regime, e.g. the production of extremeultraviolet (XUV) pulses [1, 2], which serve as the basis for much of the burgeoning field of attosecond science [3]. Assuming a Fourier-transform-limited, Gaussian pulse, the waveform can be written as E(t) = E 0 exp( t 2 /τ 2 )cos(ωt + φ), where ω is the laser field frequency, φ is the carrier-envelope phase (CEP), E 0 is the peak electric field, and the commonly-used full- (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4465

3 width at half of the maximum (FWHM) pulse duration in intensity is defined as t FWHM = τ 2ln2. Thus, for a given wavelength and peak intensity, the waveform is characterized by the pulse duration, t, along with the carrier-envelope phase (CEP), φ. Typically, the measurement of these two quantities is performed by separate devices. The CEP is most often measured and/or controlled by f -2 f interferometers [4 6], but alternative methods, such as analysis of high harmonic generation [7] and quantum interference [8], have also been developed. The pulse duration is typically measured using autocorrelation, frequencyresolved optical gating (FROG) [9,10], or spectral phase interferometry for direct electric-field reconstruction (SPIDER) [11,12]. Until now, the exceptions, which measure both pulse duration and the CEP, have been attosecond streaking [13 18] and the analysis of velocity-map images (VMI) of above-threshold ionization (ATI) from nobel gases [19, 20], which require a CEP stabilized pulse train for the lengthy measurement times and relatively complex experimental apparatuses. We have recently proposed and implemented a technique using the ATI of Xe to determine the CEP for each individual laser shot in a khz pulse train in real-time [21 23]. This technique moves beyond the initial work of Wittmann et al. [24] as it facilitates data tagging and realtime analysis and requires no theoretical assumptions to precisely determine the relative CEP. In this paper, we show how the same device can be used to simultaneously measure the pulse duration in real-time. This differs significantly from the recent work of Chen et al. [25] in that our analysis does not rely upon theoretical assumptions, e.g. those of quantitative rescattering theory (QRS) [26], and that we address how the measurement can be accomplished in real-time. We believe the apparatus and technique described herein is a viable alternative to existing fewcycle pulse length and/or CEP measurements as it (i) accomplishes both simultaneously and in real-time, (ii) is easy to install and operate, (iii) operates with and without CEP locking, and (iv) operates at repetition rates from approximately 1 Hz to tens of khz, which encompasses frequencies obtainable from TW class systems to commercially available tabletop Ti:Sapphire lasers. 2. Experimental setup Ultrashort (28 fs) laser pulses are generated by a Ti:Sapphire Femtopower Compact Pro HP / HR CEP laser system, see Fig. 1(a). The frequency spectrum is then broadened using an Ne-filled hollow-core fiber. The pulse duration is varied by changing the pressure of Ne gas within the hollow-core fiber, i.e. increasing the gas pressure within the hollow-core fiber increases the spectral broadening and, thereby, decreases the Fourier-transform limited pulse duration. Chirped mirrors (CM) are then used to compensate for the spectral phase introduced by the fiber and produce a negative chirp to accommodate the dispersion in the remaining beam paths. Next, using a thin broadband beam splitter, the laser is split into two parts one going to the stereo-ati measurement, Fig. 1(b), and the other going to the SPIDER, Fig. 1(c). Both beam paths have independent sets of fused silica wedges (W2 and W3) to fine tune the spectral phase and minimize the pulse length in both measurements Stereographic ATI measurement We utilize the facts that the ATI spectrum of Xe is dependent upon the CEP and that this dependence increases as the pulse length decreases. This is to say, the magnitude of the possible asymmetry in the electric field increases as the pulse length decreases and this asymmetry depends on the CEP and is reflected in the ATI spectrum [27]. The stereo-ati measurement apparatus [28] is designed to take advantage of this fact and produce a real-time signal for every individual laser shot in a khz pulse train corresponding to the CEP [21, 24] and pulse duration of that pulse. (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4466

4 Fig. 1. (a) Schematic of the beam path (FM: out-coupling focusing mirror, CM: chirped mirrors, PM: plane mirror, W1 W3: fused silica wedges, BS: beam splitter). (b) Schematic of the stereographic apparatus used to measure ATI [28]. (c) Schematic of the single-shot SPIDER setup (BS: beam splitter, E: etalon, WP: λ/2 waveplate, S: stretcher, Fm: focusing mirror, X: nonlinear crystal, A: aperture, OMA: optical multichannel analyzer) [11,12]. See text for details. This apparatus is depicted in Fig. 1(b) and consists of a high vacuum chamber with µ-metal shielding and two identical field-free time-of-flight (TOF) spectrometers arranged back-to-back [28]. The laser is focused into a Xe target where many atoms are ionized in each laser pulse. Those electrons emitted within a small angle around the laser polarization, 2, are detected by micro-channel plate (MCP) detectors with metal anodes to the left, L, and right, R. The ATI spectra are encoded in the time-dependent electron currents for each pulse, which are then converted to voltage signals via capacitors and amplifiers. The ATI yield is CEP dependent and the phase of this dependence varies with energy or equivalently time-of-flight (TOF) [21, 24, 27, 28]. To make this dependence more pronounced, we examine the asymmetry in the electron yield to the left (L) and right (R), i.e. A = (L R)/(L + R). In the plateau region, the asymmetry, A, varies approximately sinusoidally with the CEP. Moreover, one can choose two regions in the spectra, which will be denoted as high and low energy, in which the sinusoidal dependence of A differs by a phase of 90. That is to say, A high A 0 sin(φ +φ 0 ) and A low A 0 sin(φ +φ 0 +π/2), where φ is the CEP, φ 0 is an arbitrary offset, and A 0 is the amplitude of the asymmetry. In practice, the two energy regions are chosen by varying the bounds until two parameters are optimized: (i) the uniformity of the radius, i.e. the standard deviation in r is minimized, and (ii) the isotropic distribution of points in θ, i.e. the standard deviation in N(θ) is minimized. Finally, by plotting the two asymmetry values against one another in a parametric asymmetry plot (PAP), one finds that the polar angle (θ) corresponds to the CEP (φ), i.e. φ θ + φ 0. See Fig. 2(a) for typical data. Note that although the dependence of φ on θ deviates slightly from being purely linear, one can determine φ(θ) exactly using a pulse train in which the CEP is random and uniformly distributed [21]. In addition to revealing the CEP, the PAP is also dependent upon the pulse duration. Namely, the radial coordinate, r, in the PAP is related to the pulse duration, t. As the pulse length decreases the amplitude of the left-right-asymmetry (A 0 ) increases, i.e. as the pulse length moves (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4467

5 Fig. 2. (a) Parametric asymmetry plots (PAP) for 4.02 (black), 5.70 (red), and 7.20 fs (blue). Each laser shot produces one point, 80,000 points are shown for each distribution, and the dashed circles mark the average radii for the 3 distributions. In these measurements the CEP is freely and randomly changing and uniformly distributed. (b) Radius of the PAP, r, as a function of pulse length (FWHM in intensity, t), where the radius is from the measured PAP and the pulse length is measured with a SPIDER (open circles). The error bars on the data points represent the standard deviation in the single-shot radial measurement and uncertainty in the pulse length measurement of the SPIDER. The data is fit with the function r = 1 exp( α/( t β) 2 ), where α = ± , β = ± , and R 2 = Additionally, the uncertainty in the pulse length measurement using a single laser shot (squares) and the ensemble of laser shots (triangles) is displayed. Points calculated using quantitative rescattering theory (QRS) [25] for a given pulse length (filled circles) are also shown. See text for details. from a many-cycle pulse to a few-cycle pulse, A 0 moves from 0 to 1. Moreover, as r A 0, the radial size of the PAP will increase as the pulse length decreases. This trend is illustrated in Fig. 2(a) using three different pulse lengths Few-cycle SPIDER For spectral phase sensitive pulse characterization, we used a commercial SPIDER system (FC SPIDER by APE GmbH) that is specifically designed to measure few-cycle pulses [11]. Fig. 1(c) shows the schematic setup of this device, which splits the laser into a spectral amplitude characterization part with a fundamental spectrometer (OMA1) and a spectral phase characterization part with a second spectrometer (OMA2) for recording the up-converted pulses. The introduction of the spectral shear between the two test pulses is realized by their noncollinear type-ii interaction with the third, stretched pulse. The resulting sum-frequency generation (SFG) signal is detected by an UV-sensitive spectrometer. The incidence angle at the etalon is balanced between a higher Fresnel reflectivity and reduced intensity modulation of the transmitted beam for robust phase detection [12]. To support the robustness of the measurement, especially in case of fluctuating laser sources, the spectral power density is measured independently, yet synchronously with the spectral phase. (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4468

6 3. Results and discussion 3.1. pulse duration Using the stereo-ati and SPIDER measurements in tandem, we are able to determine the dependence of the radial dimension in the PAP, r, on the pulse duration, t. This relationship is shown in Fig. 2(b) and closely fits a function of the form r = 1 exp( α/( t β) 2 ). In the measured range, the slope of this curve increases as the pulse length decreases, so the measurement is more precise as the pulse length decreases. For few-cycle pulses roughly in the range of 4 to 7 fs, the radial dependence is especially strong and allows one to determine pulse length differences of a few 100 attoseconds. Additionally, this calibration does not depend upon any theoretical assumptions and is in rough agreement with the limited number of data points predicted using quantitative rescattering theory (QRS) [25] (see filled circles in Fig. 2(b)). The aforementioned fitting function is based on a simple model. The peak value of a cosine pulse is E(t=0) = E 0 and the absolute value at the maximum of the next half cycle is E(t=π/ω) = E 0 exp( (π/ωτ) 2 ). Thus, if the half-cycle yields depend on the peak values of the electric field to some power, we expect the L-R asymmetry in the ATI yield to follow the form 1 exp( α/ t 2 ). Additionally, the offset, β, is added to better fit the data and can be thought of as the minimum pulse length required to produce rescattered electrons. Although this model is quite crude, it fits the data extremely well, with α = ± , β = ± , and R 2 = Inverting this fit yields the pulse length as a function of the PAP radius, t = β + α/ln(1 r). Using this formula and propagating the uncertainties in the fit and radial measurement, one can determine the uncertainty in the stereo-ati pulse length measurement. As one would expect and shown in Fig. 2(b), the error when using one laser shot (squares) is larger than when using a large ensemble of laser shots (triangles). However, unlike the CEP, which can vary over the full 2π range from shot-to-shot, the pulse duration is typically much more stable. Therefore, using the average radial value along with the single-shot CEP value still allows one to determine the waveform of individual laser pulses in a train. Furthermore, the number of values being averaged can be easily varied from one to many depending on the desired application Spectral phase As compared to methods that retrieve the spectral phase of the pulse, e.g. SIPDER [11, 12] or frequency-resolved optical gating (FROG) [9,10], our technique has a distinct disadvantage we must assume a temporal Gaussian pulse shape. In many cases this is an appropriate assumption as spectral phase introduced by frequency broadening, e.g. hollow core fiber compression, is well compensated for using the appropriate chirped-mirrors. However, when one pushes the limits towards shorter pulses, the time-bandwidth product (TBP) typically increases to a point where assuming a Gaussian pulse shape is erroneous. This is illustrated in Figs. 3(a d), which show the intensity envelopes and the spectral representation of a relatively Gaussian 6.3 fs pulse and a more complex 4.1 fs pulse. Nevertheless, as our technique is insensitive to structures below 30% of the peak intensity, the stereo-ati measurement provides an excellent measurement of the pulse duration of the primary intensity envelope. Moreover, as many strong-field processes show a highly exponential dependence on the electric field, determination of primary pulse structure is often adequate. Although our technique does not retrieve the spectral phase, some general information about the spectral phase can be determined. The more the spectral phase deviates from being flat, the smaller the maximum achievable radius of the PAP, rmax, will be with respect to the radius corresponding to the Fourier transform limited (FTL) temporal pulse duration, r FTL. In other (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4469

7 Relative Intensity 1,0 (a) 0,8 0,6 0,4 0,2 0,0 (c) 0,8 0,6 0,4 0,2 0, Time (fs) (b) 6.27 fs (d) 4.08 fs Intensity Phase Intensity Phase ,0 (e) 0, ,0 0,5 1,0 1,5 Wavelength (nm) fused silica (mm) Fig. 3. (a) (d) Temporal and frequency spectra for 6.27 (top two panels) and 4.08 fs (bottom two panels) pulses derived from a SPIDER measurement. (e) Typical data for the PAP radius, r, as a function of fused silica introduced in the beam path for a few-cycle pulse with poorly balanced higher-order dispersion. (f) Same as (e) transformed to pulse length using the aforementioned r t conversion. See text for details. Relative Phase (rad.) Radius Pulse Length (fs) 0,6 0,4 0, (f) words, the closer the measured pulse duration is to the FTL and rmax r FTL, the flatter the spectral phase. In practice, one will optimize the pulse duration by varying the amount of dispersive material in the beam path, e.g. by inserting fused silica wedges (W1 in Fig. 1(a)). A pulse carrying higher-order dispersion will typically lengthen and shorten in a non-monotonic way as dispersion is added or removed. This is because the phase for different parts of the spectrum becomes linear for different amounts of fused silica dispersion. For pulses with poorly balanced higherorder dispersion, we observe several local maxima for the radius, r, of the PAP as a function of the glass thickness (see Figs. 3(e) and (f)), while spectra with well balanced dispersion exhibit a single maximum. In general, the closer the radius of the PAP is to the FTL and the fewer and closer together the minima are in the dispersion scan, the flatter the spectral phase. Thus, one can use the stereo-ati measurement alone to optimize the spectral phase Waveform characterization The most important advantage of our technique is that the stereo-ati measurement also yields the CEP of each laser pulse. Knowing the laser power and frequency and assuming a Gaussian pulse, this information allows one to reconstruct the time-dependent electric field of each pulse. To our knowledge, this is the only device capable of retrieving the approximate temporal waveform for single few-cycle laser pulses. In addition to the stereo-ati apparatus, we have developed and employ electronics, which allow for the calculation of the asymmetry parameters (A high and A low ) along with r and θ within 20 µs of the laser interaction [21, 23]. This combination enables real-time characterization of the waveform for each laser pulse in a khz pulse train. That is to say: (i) There is no dead time between laser shots or groups of laser shots. (ii) The parameters are determined for each laser shot completely independent of adjacent pulses, i.e. although values from multiple pulses can be subsequently averaged to decrease error if so desired, there is no inherent averaging. These properties make this technique ideal for data tagging [21 23] and feedback (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4470

8 loops. Moreover, these capabilities make for a highly effective tool for tuning and monitoring ultrashort pulse characteristics. By simply displaying the asymmetry parameters on an oscilloscope in parametric mode, one has a continuous real-time monitor of the pulse characteristics while optimizing the pulse to the desired specifications. Furthermore, as the stereo-ati requires the optical alignment of just two elements the focusing mirror and the interaction chamber, the apparatus is trivial to align. Additionally, only 30 µj of pulse energy is needed. Thus, when a small portion of the laser energy can be sacrificed, this measurement/monitoring can be done in parallel to a primary measurement by splitting off a portion of the main laser beam. 4. Conclusion In conclusion, we have demonstrated a novel technique to determine the approximate waveform of few-cycle Ti:Sapphire laser pulses using the ATI spectrum of Xe. In addition to allowing for the single-shot CEP determining and tagging [21 24], this technique allows for the simultaneous retrieval of the pulse duration without the need for CEP locking. This technique relies upon no theoretical assumptions and has been calibrated using a few-cycle SPIDER [11, 12]. The measurement is applicable to sub-10 fs pulses and is especially sensitive to changes in pulse duration for sub-6 fs pulses, where we estimate the accuracy to be better than ±0.4 fs. Moreover, the real-time response of the system is ideal for the feedback and monitoring necessary to achieve pulse durations pushing the limits of current Ti:Sapphire laser sources. Because of these properties along with the ease of installation and operation, we believe that this technique is a viable alternative to existing few-cycle pulse length and/or CEP measurements. Acknowledgements This work was supported by LaserLab Europe and a grant PA 730/4 from the German Research Foundation (DFG). (C) 2011 OSA 28 February 2011 / Vol. 19, No. 5 / OPTICS EXPRESS 4471

Precision control of carrier-envelope phase in grating based chirped pulse amplifiers

Precision control of carrier-envelope phase in grating based chirped pulse amplifiers Precision control of carrier-envelope phase in grating based chirped pulse amplifiers Chengquan Li, Eric Moon, Hiroki Mashiko, Christopher M. Nakamura, Predrag Ranitovic, Chakra M. Maharjan, C. Lewis Cocke,

More information

Spider Pulse Characterization

Spider Pulse Characterization Spider Pulse Characterization Spectral and Temporal Characterization of Ultrashort Laser Pulses The Spider series by APE is an all-purpose and frequently used solution for complete characterization of

More information

High-Energy 6.2-fs Pulses for Attosecond Pulse Generation

High-Energy 6.2-fs Pulses for Attosecond Pulse Generation Laser Physics, Vol. 15, No. 6, 25, pp. 838 842. Original Text Copyright 25 by Astro, Ltd. Copyright 25 by MAIK Nauka /Interperiodica (Russia). ATTOSECOND SCIENCE AND TECHNOLOGY High-Energy 6.2-fs Pulses

More information

Generating coherent broadband continuum soft-x-ray radiation by attosecond ionization gating

Generating coherent broadband continuum soft-x-ray radiation by attosecond ionization gating Generating coherent broadband continuum soft-x-ray radiation by attosecond ionization gating Thomas Pfeifer, Aurélie Jullien, Mark J. Abel, Phillip M. Nagel, Lukas Gallmann, Daniel M. Neumark, Stephen

More information

Long-term carrier-envelope-phase stabilization of a femtosecond laser by the direct locking method

Long-term carrier-envelope-phase stabilization of a femtosecond laser by the direct locking method Long-term carrier-envelope-phase stabilization of a femtosecond laser by the direct locking method Jae-hwan Lee 1, Yong Soo Lee 1, Juyun Park 1, Tae Jun Yu 2, and Chang Hee Nam 1 1 Dept. of Physics and

More information

Control of the frequency comb from a modelocked Erbium-doped fiber laser

Control of the frequency comb from a modelocked Erbium-doped fiber laser Control of the frequency comb from a modelocked Erbium-doped fiber laser Jens Rauschenberger*, Tara M. Fortier, David J. Jones, Jun Ye, and Steven T. Cundiff JILA, University of Colorado and National Institute

More information

Modified Spectrum Auto-Interferometric Correlation. (MOSAIC) for Single Shot Pulse Characterization

Modified Spectrum Auto-Interferometric Correlation. (MOSAIC) for Single Shot Pulse Characterization To appear in OPTICS LETTERS, October 1, 2007 / Vol. 32, No. 19 Modified Spectrum Auto-Interferometric Correlation (MOSAIC) for Single Shot Pulse Characterization Daniel A. Bender* and Mansoor Sheik-Bahae

More information

Characterization of Chirped volume bragg grating (CVBG)

Characterization of Chirped volume bragg grating (CVBG) Characterization of Chirped volume bragg grating (CVBG) Sobhy Kholaif September 7, 017 1 Laser pulses Ultrashort laser pulses have extremely short pulse duration. When the pulse duration is less than picoseconds

More information

Simultaneous measurement of two different-color ultrashort pulses on a single shot

Simultaneous measurement of two different-color ultrashort pulses on a single shot Wong et al. Vol. 29, No. 8 / August 2012 / J. Opt. Soc. Am. B 1889 Simultaneous measurement of two different-color ultrashort pulses on a single shot Tsz Chun Wong,* Justin Ratner, and Rick Trebino School

More information

Remote characterization and dispersion compensation of amplified shaped femtosecond pulses using MIIPS

Remote characterization and dispersion compensation of amplified shaped femtosecond pulses using MIIPS Remote characterization and dispersion compensation of amplified shaped femtosecond pulses using MIIPS I. Pastirk Biophotonic Solutions, Inc. Okemos, MI 48864 pastirk@biophotonicsolutions.com X. Zhu, R.

More information

How to build an Er:fiber femtosecond laser

How to build an Er:fiber femtosecond laser How to build an Er:fiber femtosecond laser Daniele Brida 17.02.2016 Konstanz Ultrafast laser Time domain : pulse train Frequency domain: comb 3 26.03.2016 Frequency comb laser Time domain : pulse train

More information

Generation and Control of Ultrashort Supercontinuum Pulses

Generation and Control of Ultrashort Supercontinuum Pulses Generation and Control of Ultrashort Supercontinuum Pulses Franziska Kirschner, Mansfield College, University of Oxford September 10, 2014 Abstract Supercontinuum laser pulses in the visible and near infrared

More information

Figure1. To construct a light pulse, the electric component of the plane wave should be multiplied with a bell shaped function.

Figure1. To construct a light pulse, the electric component of the plane wave should be multiplied with a bell shaped function. Introduction The Electric field of a monochromatic plane wave is given by is the angular frequency of the plane wave. The plot of this function is given by a cosine function as shown in the following graph.

More information

Ultrafast Optical Physics II (SoSe 2017) Lecture 9, June 16

Ultrafast Optical Physics II (SoSe 2017) Lecture 9, June 16 Ultrafast Optical Physics II (SoSe 2017) Lecture 9, June 16 9 Pulse Characterization 9.1 Intensity Autocorrelation 9.2 Interferometric Autocorrelation (IAC) 9.3 Frequency Resolved Optical Gating (FROG)

More information

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers Optical phase-coherent link between an optical atomic clock and 1550 nm mode-locked lasers Kevin W. Holman, David J. Jones, Steven T. Cundiff, and Jun Ye* JILA, National Institute of Standards and Technology

More information

Single-shot velocity-map imaging of attosecond light-field control at kilohertz rate

Single-shot velocity-map imaging of attosecond light-field control at kilohertz rate Single-shot velocity-map imaging of attosecond light-field control at kilohertz rate F. Süßmann, S. Zherebtsov, J. Plenge, Nora G. Johnson, M. Kübel, A. M. Sayler, V. Mondes, C. Graf, E. Rühl, G. G. Paulus,

More information

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015 Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015 Chapter 9: Optical Parametric Amplifiers and Oscillators 9.8 Noncollinear optical parametric amplifier (NOPA) 9.9 Optical parametric chirped-pulse

More information

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES Luca Poletto CNR - Institute of Photonics and Nanotechnologies Laboratory for UV and X-Ray Optical Research Padova, Italy e-mail:

More information

Chad A. Husko 1,, Sylvain Combrié 2, Pierre Colman 2, Jiangjun Zheng 1, Alfredo De Rossi 2, Chee Wei Wong 1,

Chad A. Husko 1,, Sylvain Combrié 2, Pierre Colman 2, Jiangjun Zheng 1, Alfredo De Rossi 2, Chee Wei Wong 1, SOLITON DYNAMICS IN THE MULTIPHOTON PLASMA REGIME Chad A. Husko,, Sylvain Combrié, Pierre Colman, Jiangjun Zheng, Alfredo De Rossi, Chee Wei Wong, Optical Nanostructures Laboratory, Columbia University

More information

GRENOUILLE.

GRENOUILLE. GRENOUILLE Measuring ultrashort laser pulses the shortest events ever created has always been a challenge. For many years, it was possible to create ultrashort pulses, but not to measure them. Techniques

More information

Increased-bandwidth in ultrashort-pulse measurement using an angle-dithered nonlinear-optical crystal

Increased-bandwidth in ultrashort-pulse measurement using an angle-dithered nonlinear-optical crystal Increased-bandwidth in ultrashort-pulse measurement using an angle-dithered nonlinear-optical crystal PatrickO Shea,MarkKimmel,XunGu,andRickTrebino Georgia Institute of Technology, School of Physics, Atlanta,

More information

A CW seeded femtosecond optical parametric amplifier

A CW seeded femtosecond optical parametric amplifier Science in China Ser. G Physics, Mechanics & Astronomy 2004 Vol.47 No.6 767 772 767 A CW seeded femtosecond optical parametric amplifier ZHU Heyuan, XU Guang, WANG Tao, QIAN Liejia & FAN Dianyuan State

More information

Carrier envelope phase effects on polarization gated attosecond spectra

Carrier envelope phase effects on polarization gated attosecond spectra Carrier envelope phase effects on polarization gated attosecond spectra Mahendra Man Shakya, S.Gilbertson, Hiroki Mashiko, C.Nakamura,C. Li, E.Moon, Z.Duan, Jason Tackett, and Zenghu Chang a J.R.Macdonald

More information

Pulse stretching and compressing using grating pairs

Pulse stretching and compressing using grating pairs Pulse stretching and compressing using grating pairs A White Paper Prof. Dr. Clara Saraceno Photonics and Ultrafast Laser Science Publication Version: 1.0, January, 2017-1 - Table of Contents Dispersion

More information

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory ULTRAFAST THEORY The distinguishing aspect of femtosecond laser optics design is the need to control the phase characteristic of the optical system over the requisite wide pulse bandwidth. CVI Laser Optics

More information

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT In this chapter, the experimental results for fine-tuning of the laser wavelength with an intracavity liquid crystal element

More information

Propagation, Dispersion and Measurement of sub-10 fs Pulses

Propagation, Dispersion and Measurement of sub-10 fs Pulses Propagation, Dispersion and Measurement of sub-10 fs Pulses Table of Contents 1. Theory 2. Pulse propagation through various materials o Calculating the index of refraction Glass materials Air Index of

More information

Extremely simple device for measuring 1.5-µm ultrashort laser pulses

Extremely simple device for measuring 1.5-µm ultrashort laser pulses Extremely simple device for measuring 1.5-µm ultrashort laser pulses Selcuk Akturk, Mark Kimmel, and Rick Trebino School of Physics, Georgia Institute of Technology, Atlanta, Georgia 30332-0430, USA akturk@socrates.physics.gatech.edu

More information

Case Study: Simplifying Access to High Energy sub-5-fs Pulses

Case Study: Simplifying Access to High Energy sub-5-fs Pulses Case Study: Simplifying Access to High Energy sub-5-fs Pulses High pulse energy and long term stability from a one-box Coherent Astrella ultrafast amplifier, together with a novel hollow fiber compressor

More information

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation Z. Wu, H. Loos, Y. Shen, B. Sheehy, E. D. Johnson, S. Krinsky, J. B. Murphy, T. Shaftan,, X.-J. Wang, L. H. Yu,

More information

atom physics seminar ultra short laser pulses

atom physics seminar ultra short laser pulses atom physics seminar ultra short laser pulses creation and application ultra short laser pulses overview what? - why? - how? creation and optimisation typical experimental setup properties of existing

More information

High energy femtosecond OPA pumped by 1030 nm Nd:KGW laser.

High energy femtosecond OPA pumped by 1030 nm Nd:KGW laser. High energy femtosecond OPA pumped by 1030 nm Nd:KGW laser. V. Kozich 1, A. Moguilevski, and K. Heyne Institut für Experimentalphysik, Freie Universität Berlin, Arnimallee 14, D-14195 Berlin, Germany Abstract

More information

taccor Optional features Overview Turn-key GHz femtosecond laser

taccor Optional features Overview Turn-key GHz femtosecond laser taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond

More information

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally

More information

Isolated sub-30-attosecond pulse generation using a multicycle two-color chirped laser and a static electric field

Isolated sub-30-attosecond pulse generation using a multicycle two-color chirped laser and a static electric field Chin. Phys. B Vol., No. 4 (14) 4 Isolated sub--attosecond pulse generation using a multicycle two-color chirped laser and a static electric field Zhang Gang-Tai( 张刚台 ) Department of Physics and Information

More information

Designing for Femtosecond Pulses

Designing for Femtosecond Pulses Designing for Femtosecond Pulses White Paper PN 200-1100-00 Revision 1.1 July 2013 Calmar Laser, Inc www.calmarlaser.com Overview Calmar s femtosecond laser sources are passively mode-locked fiber lasers.

More information

pulsecheck The Modular Autocorrelator

pulsecheck The Modular Autocorrelator pulsecheck The Modular Autocorrelator Pulse Measurement Perfection with the Multitalent from APE It is good to have plenty of options at hand. Suitable for the characterization of virtually any ultrafast

More information

Optimization of supercontinuum generation in photonic crystal fibers for pulse compression

Optimization of supercontinuum generation in photonic crystal fibers for pulse compression Optimization of supercontinuum generation in photonic crystal fibers for pulse compression Noah Chang Herbert Winful,Ted Norris Center for Ultrafast Optical Science University of Michigan What is Photonic

More information

A new picosecond Laser pulse generation method.

A new picosecond Laser pulse generation method. PULSE GATING : A new picosecond Laser pulse generation method. Picosecond lasers can be found in many fields of applications from research to industry. These lasers are very common in bio-photonics, non-linear

More information

Applied Physics B Lasers and Optics. m. hirasawa 1,3, n. nakagawa 1,3 k. yamamoto 1,3 r. morita 1,3 h. shigekawa 2,3 m.

Applied Physics B Lasers and Optics. m. hirasawa 1,3, n. nakagawa 1,3 k. yamamoto 1,3 r. morita 1,3 h. shigekawa 2,3 m. Appl. Phys. B 74 [Suppl.], S225 S229 (2002) DOI: 10.1007/s00340-002-0891-y Applied Physics B Lasers and Optics m. hirasawa 1,3, n. nakagawa 1,3 k. yamamoto 1,3 r. morita 1,3 h. shigekawa 2,3 m. yamashita

More information

Carrier-envelope phase stabilization of modelocked lasers

Carrier-envelope phase stabilization of modelocked lasers Carrier-envelope phase stabilization of modelocked lasers Tara M. Fortier, David J. Jones, Jun Ye and Steven T. Cundiff JILA, University of Colorado and National Institute of Standards and Technology,

More information

Quantifying noise in ultrafast laser sources and its effect on nonlinear applications

Quantifying noise in ultrafast laser sources and its effect on nonlinear applications Quantifying noise in ultrafast laser sources and its effect on nonlinear applications Vadim V. Lozovoy, 1 Gennady Rasskazov, 1 Dmitry Pestov, 3 and Marcos Dantus 1,2,3,* 1 Department of Chemistry, Michigan

More information

Real-time inversion of polarization gate frequency-resolved optical gating spectrograms

Real-time inversion of polarization gate frequency-resolved optical gating spectrograms Real-time inversion of polarization gate frequency-resolved optical gating spectrograms Daniel J. Kane, Jeremy Weston, and Kai-Chien J. Chu Frequency-resolved optical gating FROG is a technique used to

More information

APE Autocorrelator Product Family

APE Autocorrelator Product Family APE Autocorrelator Product Family APE Autocorrelators The autocorrelator product family by APE includes a variety of impressive features and properties, designed to cater for a wide range of ultrafast

More information

Testing with Femtosecond Pulses

Testing with Femtosecond Pulses Testing with Femtosecond Pulses White Paper PN 200-0200-00 Revision 1.3 January 2009 Calmar Laser, Inc www.calmarlaser.com Overview Calmar s femtosecond laser sources are passively mode-locked fiber lasers.

More information

Time-Resolved Optical Gating Based on Dispersive Propagation: A New Method to Characterize Optical Pulses

Time-Resolved Optical Gating Based on Dispersive Propagation: A New Method to Characterize Optical Pulses IEEE JOURNAL OF QUANTUM ELECTRONICS, VOL. 36, NO. 2, FEBRUARY 2000 137 Time-Resolved Optical Gating Based on Dispersive Propagation: A New Method to Characterize Optical Pulses Roger G. M. P. Koumans and

More information

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

SUPPLEMENTARY INFORMATION DOI: /NPHOTON Supplementary Methods and Data 1. Apparatus Design The time-of-flight measurement apparatus built in this study is shown in Supplementary Figure 1. An erbium-doped femtosecond fibre oscillator (C-Fiber,

More information

Supplementary material

Supplementary material Supplementary material Supplementary Figures Supplementary Figure 1. a) A general scheme of the experimental setup and the mid-ir SEA-SPIDER pulse characterization apparatus. BS beam splitter, M mirror,

More information

ULTRAFAST LASER DIAGNOSTICS

ULTRAFAST LASER DIAGNOSTICS ULTRAFAST LASER DIAGNOSTICS USE OUR APP IN YOUR LAB The faster way to master nonlinear phenomena... Wavelength conversion calculator Bandwidth and pulse duration Frequency conversion Bandwidth conversion

More information

XUV FREQUENCY COMB SPECTROSCOPY

XUV FREQUENCY COMB SPECTROSCOPY 1 XUV FREQUENCY COMB SPECTROSCOPY C. GOHLE, D. Z. KANDULA, T. J. PINKERT, W. UBACHS, and K.S.E. EIKEMA Laser Centre, Vrije Universiteit, De Boelelaan 1081, 1081 HV, Amsterdam, The Netherlands E-mail: KSE.Eikema@few.vu.nl

More information

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

Timing Noise Measurement of High-Repetition-Rate Optical Pulses 564 Timing Noise Measurement of High-Repetition-Rate Optical Pulses Hidemi Tsuchida National Institute of Advanced Industrial Science and Technology 1-1-1 Umezono, Tsukuba, 305-8568 JAPAN Tel: 81-29-861-5342;

More information

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION: Theoretical Approach Why do we need ultra short technology?? INTRODUCTION: Generating ultrashort laser pulses that last a few femtoseconds is a highly active area of research that is finding applications

More information

A Multiwavelength Interferometer for Geodetic Lengths

A Multiwavelength Interferometer for Geodetic Lengths A Multiwavelength Interferometer for Geodetic Lengths K. Meiners-Hagen, P. Köchert, A. Abou-Zeid, Physikalisch-Technische Bundesanstalt, Braunschweig Abstract: Within the EURAMET joint research project

More information

Ultrafast instrumentation (No Alignment!)

Ultrafast instrumentation (No Alignment!) Ultrafast instrumentation (No Alignment!) We offer products specialized in ultrafast metrology with strong expertise in the production and characterization of high energy ultrashort pulses. We provide

More information

Photon Diagnostics. FLASH User Workshop 08.

Photon Diagnostics. FLASH User Workshop 08. Photon Diagnostics FLASH User Workshop 08 Kai.Tiedtke@desy.de Outline What kind of diagnostic tools do user need to make efficient use of FLASH? intensity (New GMD) beam position intensity profile on the

More information

G. Norris* & G. McConnell

G. Norris* & G. McConnell Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry G. Norris* & G. McConnell Centre

More information

THE GENERATION and characterization of ultrafast

THE GENERATION and characterization of ultrafast 20 IEEE JOURNAL OF QUANTUM ELECTRONICS, VOL. 37, NO. 1, JANUARY 2001 Aberrations in Temporal Imaging Corey V. Bennett, Student Member, IEEE, and Brian H. Kolner, Member, IEEE Abstract Recent advances in

More information

Enhanced bandwidth of supercontinuum generated in microstructured fibers

Enhanced bandwidth of supercontinuum generated in microstructured fibers Enhanced bandwidth of supercontinuum generated in microstructured fibers G. Genty, M. Lehtonen, and H. Ludvigsen Fiber-Optics Group, Department of Electrical and Communications Engineering, Helsinki University

More information

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features:

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features: Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family Vitara is the new industry standard for hands-free, integrated, ultra-broadband, flexible ultrafast lasers. Representing the culmination

More information

Control of coherent light and its broad applications

Control of coherent light and its broad applications Control of coherent light and its broad applications Jun Ye, R. J. Jones, K. Holman, S. Foreman, D. J. Jones, S. T. Cundiff, J. L. Hall, T. M. Fortier, and A. Marian JILA, National Institute of Standards

More information

Stability of a Fiber-Fed Heterodyne Interferometer

Stability of a Fiber-Fed Heterodyne Interferometer Stability of a Fiber-Fed Heterodyne Interferometer Christoph Weichert, Jens Flügge, Paul Köchert, Rainer Köning, Physikalisch Technische Bundesanstalt, Braunschweig, Germany; Rainer Tutsch, Technische

More information

The Measurement of Ultrashort Laser Pulses

The Measurement of Ultrashort Laser Pulses The Measurement of Ultrashort Laser Pulses To spectrometer SHG crystal Fresnel biprism beamsplitter Cylindrical lens Etalon Oppositely tilted pulses Lens Prof. Rick Trebino Input pulse Georgia Tech & Swamp

More information

quantiflash Calibration Light Source for Cytometry

quantiflash Calibration Light Source for Cytometry quantiflash Calibration Light Source for Cytometry quantiflash Key Facts Cytometer calibration with light pulses Routine detector / PMT performance test Distinguish dim populations from noise Calibrate

More information

High Power and Energy Femtosecond Lasers

High Power and Energy Femtosecond Lasers High Power and Energy Femtosecond Lasers PHAROS is a single-unit integrated femtosecond laser system combining millijoule pulse energies and high average powers. PHAROS features a mechanical and optical

More information

Direct measurement and analysis of the carrier-envelope phase in light pulses approaching the single-cycle regime

Direct measurement and analysis of the carrier-envelope phase in light pulses approaching the single-cycle regime Direct measurement and analysis of the carrier-envelope phase in light pulses approaching the single-cycle regime P Dombi 1,7, A Apolonski 1,2, Ch Lemell 3, G G Paulus 4, M Kakehata 5, R Holzwarth 6,ThUdem

More information

Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers

Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers Natsuki Fujiwara and Junji Ohtsubo Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu, 432-8561 Japan

More information

The Proposed MIT X-ray Laser Facility: Laser Seeding to Achieve the Transform Limit

The Proposed MIT X-ray Laser Facility: Laser Seeding to Achieve the Transform Limit MIT X-ray Laser Project The Proposed MIT X-ray Laser Facility: Laser Seeding to Achieve the Transform Limit 30 or more independent beamlines Fully coherent milli-joule pulses at khz rates Wavelength range

More information

THE GENERATION of ultrashort laser pulses with durations

THE GENERATION of ultrashort laser pulses with durations IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, VOL. 2, NO. 3, SEPTEMBER 1996 575 Measurement of 10-fs Laser Pulses Greg Taft, Andy Rundquist, Margaret M. Murnane, Member, IEEE, Ivan P. Christov,

More information

All-Optical Signal Processing and Optical Regeneration

All-Optical Signal Processing and Optical Regeneration 1/36 All-Optical Signal Processing and Optical Regeneration Govind P. Agrawal Institute of Optics University of Rochester Rochester, NY 14627 c 2007 G. P. Agrawal Outline Introduction Major Nonlinear Effects

More information

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 ) 레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 ) Contents Frequency references Frequency locking methods Basic principle of loop filter Example of lock box circuits Quantifying frequency stability Applications

More information

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1 Spectral phase shaping for high resolution CARS spectroscopy around 3 cm A.C.W. van Rhijn, S. Postma, J.P. Korterik, J.L. Herek, and H.L. Offerhaus Mesa + Research Institute for Nanotechnology, University

More information

Incident IR Bandwidth Effects on Efficiency and Shaping for Third Harmonic Generation of Quasi-Rectangular UV Longitudinal Profiles *

Incident IR Bandwidth Effects on Efficiency and Shaping for Third Harmonic Generation of Quasi-Rectangular UV Longitudinal Profiles * LCLS-TN-05-29 Incident IR Bandwidth Effects on Efficiency and Shaping for Third Harmonic Generation of Quasi-Rectangular UV Longitudinal Profiles * I. Introduction Paul R. Bolton and Cecile Limborg-Deprey,

More information

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017 R. J. Jones College of Optical Sciences OPTI 511L Fall 2017 Active Modelocking of a Helium-Neon Laser The generation of short optical pulses is important for a wide variety of applications, from time-resolved

More information

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO. a Nd:YSO resonator array µm Transmission spectrum (a. u.) b 4 F3/2-4I9/2 25 2 5 5 875 88 λ(nm) 885 Supplementary Figure. An array of nano-beam resonators fabricated in Nd:YSO. (a) Scanning electron microscope

More information

Simultaneous compression and characterization of ultrashort laser pulses using chirped mirrors and glass wedges

Simultaneous compression and characterization of ultrashort laser pulses using chirped mirrors and glass wedges Simultaneous compression and characterization of ultrashort laser pulses using chirped mirrors and glass wedges Miranda, Miguel; Fordell, Thomas; Arnold, Cord; L'Huillier, Anne; Crespo, Helder Published

More information

Low threshold power density for the generation of frequency up-converted pulses in bismuth glass by two crossing chirped femtosecond pulses

Low threshold power density for the generation of frequency up-converted pulses in bismuth glass by two crossing chirped femtosecond pulses Low threshold power density for the generation of frequency up-converted pulses in bismuth glass by two crossing chirped femtosecond pulses Hang Zhang, Hui Liu, Jinhai Si, * Wenhui Yi, Feng Chen, and Xun

More information

Swept Wavelength Testing:

Swept Wavelength Testing: Application Note 13 Swept Wavelength Testing: Characterizing the Tuning Linearity of Tunable Laser Sources In a swept-wavelength measurement system, the wavelength of a tunable laser source (TLS) is swept

More information

Ultrashort Pulse Measurement Using High Sensitivity Two Photon Absorption Waveguide Semiconductor

Ultrashort Pulse Measurement Using High Sensitivity Two Photon Absorption Waveguide Semiconductor Ultrashort Pulse Measurement Using High Sensitivity Two Photon Absorption Wguide Semiconductor MOHAMMAD MEHDI KARKHANEHCHI Department of Electronics, Faculty of Engineering Razi University Taghbostan,

More information

Optical pulse compression to 5.0 fs by use of only a spatial light modulator for phase compensation

Optical pulse compression to 5.0 fs by use of only a spatial light modulator for phase compensation 1742 J. Opt. Soc. Am. B/ Vol. 18, No. 11/ November 2001 Karasawa et al. Optical pulse compression to 5.0 fs by use of only a spatial light modulator for phase compensation Naoki Karasawa Department of

More information

Design and calibration of zero-additional-phase SPIDER

Design and calibration of zero-additional-phase SPIDER P. Baum and E. Riedle Vol. 22, No. 9/September 2005/ J. Opt. Soc. Am. B 1875 Design and calibration of zero-additional-phase SPIDER Peter Baum and Eberhard Riedle Lehrstuhl für BioMolekulare Optik, Ludwig-Maximilians-Universität,

More information

Laser systems for science instruments

Laser systems for science instruments European XFEL Users Meeting 27-20 January 2016, Main Auditorium (Bldg. 5), DESY, Hamburg Laser systems for science instruments M. J. Lederer WP78, European XFEL GmbH, Albert-Einstein-Ring 19, 22761 Hamburg,

More information

Ptychographic reconstruction of attosecond pulses

Ptychographic reconstruction of attosecond pulses Ptychographic reconstruction of attosecond pulses M. Lucchini, M.H. Brügmann, A. Ludwig, L. Gallmann,,,U. Keller, and T. Feurer, Department of Physics, ETH Zurich, 93 Zürich, Switzerland Institute of Applied

More information

Divided-pulse amplification for terawatt-class fiber lasers

Divided-pulse amplification for terawatt-class fiber lasers Eur. Phys. J. Special Topics 224, 2567 2571 (2015) EDP Sciences, Springer-Verlag 2015 DOI: 10.1140/epjst/e2015-02566-8 THE EUROPEAN PHYSICAL JOURNAL SPECIAL TOPICS Review Divided-pulse amplification for

More information

Attosecond technology - quantum control of high harmonic generation for phase matching

Attosecond technology - quantum control of high harmonic generation for phase matching Attosecond technology - quantum control of high harmonic generation for phase matching Xiaoshi Zhang, Amy Lytle, Oren Cohen, Ivan P. Christov, Margaret M. Murnane, Henry C. Kapteyn JILA, University of

More information

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Derek Puccio, Don Malocha, Nancy Saldanha Department of Electrical and Computer Engineering University of Central Florida

More information

Measurement of the group refractive index of air and glass

Measurement of the group refractive index of air and glass Application Note METROLOGY Czech Metrology Institute (CMI), Prague Menlo Systems, Martinsried Measurement of the group refractive index of air and glass Authors: Petr Balling (CMI), Benjamin Sprenger (Menlo

More information

Fiber Laser Chirped Pulse Amplifier

Fiber Laser Chirped Pulse Amplifier Fiber Laser Chirped Pulse Amplifier White Paper PN 200-0200-00 Revision 1.2 January 2009 Calmar Laser, Inc www.calmarlaser.com Overview Fiber lasers offer advantages in maintaining stable operation over

More information

An XUV Source using a Femtosecond Enhancement Cavity for Photoemission Spectroscopy

An XUV Source using a Femtosecond Enhancement Cavity for Photoemission Spectroscopy An XUV Source using a Femtosecond Enhancement Cavity for Photoemission Spectroscopy Arthur K. Mills a, Sergey Zhdanovich a, Alex Sheyerman a, Giorgio Levy a,b, Andrea Damascelli a,b, and David J. Jones

More information

Widely Wavelength-tunable Soliton Generation and Few-cycle Pulse Compression with the Use of Dispersion-decreasing Fiber

Widely Wavelength-tunable Soliton Generation and Few-cycle Pulse Compression with the Use of Dispersion-decreasing Fiber PIERS ONLINE, VOL. 5, NO. 5, 29 421 Widely Wavelength-tunable Soliton Generation and Few-cycle Pulse Compression with the Use of Dispersion-decreasing Fiber Alexey Andrianov 1, Sergey Muraviev 1, Arkady

More information

Control and precise measurement of carrier-envelope phase dynamics

Control and precise measurement of carrier-envelope phase dynamics Appl. Phys. B 78, 5 12 (2004) DOI: 10.1007/s00340-003-1307-3 Applied Physics B Lasers and Optics s. witte r.t. zinkstok w. hogervorst k.s.e. eikema Control and precise measurement of carrier-envelope phase

More information

FROG. In order to measure an event in time, you need a shorter one. So how do you measure the shortest one?

FROG. In order to measure an event in time, you need a shorter one. So how do you measure the shortest one? Swamp Optics, LLC. 6300 Powers Ferry Rd. Suite 600-345 Atlanta, GA 30339 +1.404.547.9267 www.swamoptics.com Swamp Optics Tutorial FROG In order to measure an event in time, you need a shorter one. So how

More information

EQUATION CHAPTER 1 SECTION 1 TOWARDS INTENSE SINGLE ATTOSECOND PULSE GENERATION FROM A 400 NM DRIVING LASER YAN CHENG

EQUATION CHAPTER 1 SECTION 1 TOWARDS INTENSE SINGLE ATTOSECOND PULSE GENERATION FROM A 400 NM DRIVING LASER YAN CHENG EQUATION CHAPTER 1 SECTION 1 TOWARDS INTENSE SINGLE ATTOSECOND PULSE GENERATION FROM A 400 NM DRIVING LASER by YAN CHENG B.A., University of Science and Technology of China, 2009 A THESIS submitted in

More information

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS By Jason O Daniel, Ph.D. TABLE OF CONTENTS 1. Introduction...1 2. Pulse Measurements for Pulse Widths

More information

Ultrafast pulse characterization using XPM in silicon

Ultrafast pulse characterization using XPM in silicon Ultrafast pulse characterization using XPM in silicon Nuh S. Yuksek, Xinzhu Sang, En-Kuang Tien, Qi Song, Feng Qian, Ivan V. Tomov, Ozdal Boyraz Department of Electrical Engineering & Computer Science,

More information

Pulse shape measurement issue ~ Pulse-stacker

Pulse shape measurement issue ~ Pulse-stacker Pulse shape measurement issue ~ Pulse-stacker stacker-based square pulse (>10 10ps) shaping system ~ Hiromistu Tomizawa Accelerator Division, Japan Synchrotron Radiation Research Institute (SPring-8) 0.

More information

Pulse Shaping Application Note

Pulse Shaping Application Note Application Note 8010 Pulse Shaping Application Note Revision 1.0 Boulder Nonlinear Systems, Inc. 450 Courtney Way Lafayette, CO 80026-8878 USA Shaping ultrafast optical pulses with liquid crystal spatial

More information

Crossed-beam spectral interferometry: a simple, high-spectral-resolution method for completely characterizing complex ultrashort pulses in real time

Crossed-beam spectral interferometry: a simple, high-spectral-resolution method for completely characterizing complex ultrashort pulses in real time Crossed-beam spectral interferometry: a simple, high-spectral-resolution method for completely characterizing complex ultrashort pulses in real time Pamela Bowlan, Pablo Gabolde, Aparna Shreenath, Kristan

More information

GA 30460, USA. Corresponding author

GA 30460, USA. Corresponding author Generation of femtosecond laser pulses tunable from 380 nm to 465 nm via cascaded nonlinear optical mixing in a noncollinear optical parametric amplifier with a type-i phase matched BBO crystal Chao-Kuei

More information

Faraday Rotators and Isolators

Faraday Rotators and Isolators Faraday Rotators and I. Introduction The negative effects of optical feedback on laser oscillators and laser diodes have long been known. Problems include frequency instability, relaxation oscillations,

More information

Phase-sensitive high-speed THz imaging

Phase-sensitive high-speed THz imaging Phase-sensitive high-speed THz imaging Toshiaki Hattori, Keisuke Ohta, Rakchanok Rungsawang and Keiji Tukamoto Institute of Applied Physics, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8573

More information