ANNEXURE 1 LIST OF EQUIPMENTS LOT 1
|
|
- Vincent Stevenson
- 5 years ago
- Views:
Transcription
1 ANNEXURE LIST OF EQUIPMENTS LOT Sl. No. Description Quantity Nos Recommended Make Digital Multimeter Fluke AC/DC Clamp meter with flexi clamp Fluke/Kyoritsu AC/DC Clamp meter(0ma to 0A) Kyoritsu/Fluke/Hioki Digital Megger(0 KV) Megger Digital Megger(0 0KV) Megger 6 Primary current Injection Kit, 000A AE/RE/Equivalent 7 Temperature Gun Fluke/Flir/Raychem 8 Portable Hydrogen Leakage Detector As per specification 9 Battery discharge resistor (0A) As per specification 0 Battery discharge resistor (00A) As per specification Phase Variac (0A) AE/RE/Equivalent Phase Variac (0A) AE/RE/Equivalent Motor checker(lcr meter) MCM or Equivalent Oil sampling bottles (SS) As per specification Low, medium & High voltage proximity detector Salisbury/Amprobe/Equivalent 6 Single phase relay test kit Megger(Sverker)/Omicron 7 Digital Tachometer(both contact & Noncontact type) Amprobe/Extech/Fluke/Testo 8 Knee point voltage Test Kit As per specification 9 Manual Earth tester As per specification 0 Vacuum bottle tester Megger or equivalent Surge arrester tester ISA/Scope
2 ANNEXURE. TECHNICAL SPECIFICATIONS FOR DIGITAL MULTIMETER Instrument should measure accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment Digit display with bright, two level backlight True RMS AC voltage and current for accurate measurements on non linear signals True RMS AC voltage and current for accurate measurements on non linear signals Selectable filter for accurate voltage and frequency measurements on motor drives 6 / digit mode for precise measurements (0,000 counts) 7 Measure up to 000 VAC and DC 8 0,000 µf capacitance range for components and motor caps Min/Max Average recording with Min/Max Alert to capture variations 9 automatically 0 Peak capture to record transients as fast as 0 µs Relative mode to remove test lead interference from low ohms measurements Auto and manual ranging for maximum flexibility Touch Hold to capture stable readings avoiding noisy signals Improved selectable sleep mode for long battery life Maximum voltage 000 V Voltage DC Accuracy ±(0.0% + ) Maximum resolution 0 µv Maximum voltage 000 V Accuracy ±(0.7% + ) True RMS 6 Voltage AC 8 khz with low pass AC bandwidth filter; khz Maximum resolution 0. mv 0 A (0 A for 0 Maximum amps seconds maximum) 7 Current DC Amps accuracy ±(0.% + ) Maximum resolution 0.0 µa 0 A (0 A for 0 Maximum amps 8 Current AC seconds maximum) Amps accuracy ±(.0% + ) True RMS
3 Maximum resolution 0. µa Maximum resistance 0 MΩ 9 Resistance Accuracy ±(0.% + ) Maximum resolution 0. Ω Maximum capacitance 9,999 µf 0 Capacitance Accuracy ±(% + ) Maximum resolution 0.0 nf Maximum frequency 00 khz Frequency Accuracy ±(0.00% + ) Maximum resolution 0.0 Hz Maximum duty cycle 99.90% Duty cycle Accuracy ±(0.% per khz + 0.%) Maximum resolution 0.0% Temperature 00.0 C 090 C measurement 8.0 F 99.0 F Maximum ns conductance Conductance Accuracy ±(.0% + 0) Maximum resolution 0.0 ns V Diode Resolution mv Accuracy ±(% + ) 6 Duty cycle range Accuracy Within ±(0.% per khz + 0.%) 7 Operating Environmental 0 C to + C temperature Specifications Storage temperature 0 C to + 60 C 8 Safety Specification Overvoltage category EN 600 to 000 V CAT III, 600V CAT IV 9 Battery Life Alkaline ~00 hours typical, without backlight 0 Shock Meter drop per IEC 600 :00. TECHNICAL SPECIFICATIONS FOR DIGITAL CLAMPMETER WITH FLEXIBLE CLAMP 000 A ac and dc current measurement 000 A ac current measurement with iflex flexible current probe 000 V ac and dc voltage measurement
4 True rms voltage and current for accurate measurements on non linear signals Frequency measurement to 00 Hz with body jaw and iflex 6 Resistance measurement to 60 kω with continuity detection Min, max, average, and inrush recording to capture variations 7 automatically 8 00 mv dc measurement range to interface with other accessories μf capacitance measurement A 0 AC Current via Jaw AC Current via Flexible Current Probe DC Current AC Voltage DC Voltage Frequency via Jaw 6 Frequency via Flexible Current Probe 7 Resistance Resolution Accuracy Crest Factor (0 Hz/60 Hz) 0. A.% ± digits (0 Hz to A 00 A Resolution 0. A ( 600 A) A ( 00 A) Accuracy % ± digits ( 00 Hz) 000 A Resolution Accuracy 0. A % ± digits 000 V Resolution 0. V ( V) V ( 000 V) Accuracy.% ± digits (0 Hz to 00 Hz) 000 V Resolution 0. V ( V) V ( 000 V) Accuracy % ± digits.0 Hz to 00.0 Hz Resolution Accuracy Resolution Accuracy 0. Hz 0.% ± digits.0 Hz to 00.0 Hz 0. Hz 0.% ± digits 60 kω Resolution 0. Ω ( 600 Ω) Accuracy % ± digits 8 Capacitance 000 μf
5 Resolution Accuracy 0. μf ( 00 μf) μ F ( 000 μf) % ± digits 9 Jaw opening Minimum mm Flexible current probe 0 Minimum.8 m cable length Safety IEC 600 0:CAT III 000 V / CAT IV 600 V. TECHNICAL SPECIFICATION FOR AC/DC MILLI AMPERE CLAMP METER High sensitivity, miniature AC/DC clamp meter 0.mA minimum resolution for AC current and ma minimum resolution for DC current. Output terminal for recorder connection. Should be suitable for measuring CT secondary, relay and transducer currents with high precision accuracy. 00mA//0A AC A 6 DC A /0A ±%rdg±dgt [0/60Hz] (00mA) ±.%rdg±8dgt [0Hz khz] (00mA) ±%rdg±dgt [0/60Hz] (A) ±.%rdg±0dgt [0Hz khz] (/0A) ±%rdg±dgt (A) ±.%rdg±dgt (0A) 7 Conductor size Ø7.mm max. 8 Frequency response DC, 0Hz khz 9 Output Recorder : DC00mV against AC00mA//0A DC00mV against DC/0A 0 Power source Rechargeable battery AC Adaptor Accessories Carrying Case Instruction Manual
6 . TECHNICAL SPECIFICATION FOR DIGITAL MEGGER (KV) The instrument should perform automatic tests and measure insulation resistance, current, capacitance, polarization index. Instrument should display direct reading of voltage across the test piece, pi value. The tester shall be suitable for DC battery operation and ac mains operation. The DC batteries should be Digital and software filter should be available in the instrument to remove induced noise. Capacitor charging time should be available. 6 Auto discharge feature should be available. Instrument should have high voltage warning display when input voltage 7 across the terminal is above 0V. 8 Guard: % error guarding 00KΩ leakage with 00MΩ load 9 Measuring range 0KΩ to 0TΩ 0 Analog display Resistance range 00KΩ to 0TΩ Test Voltage s (DC) 00 V, 000 V, 00 V, 000 V, USER DEFINED TEST VOLTAGE: 00 V TO KV IN 0 V STEPS, KV TO KV IN V STEPS, Withstanding Test Voltage kv Leakage Current ma or higher Voltage Measurement AC/DC 0 V to 660 V AC or DC, 0/60 Hz Accuracy ±% to TΩ, ±0% to 0TΩ 6 Polarization Index (PI) Auto 7 Capacitance and time constant nf to 0µF 8 Power Supply Independent mains as well as battery operated 9 Protection Classification Meets the requirements of IEC 600, CATIV 600 V 0 Over Voltage Category CATIV Degree of Protection IP6 (lid closed), IP0 (lid open) Visual and Sound Warnings Yes Display Large LCD display with automatic backlight Working Temperature 0 C to 0 C 6
7 Storage Temperature 0 C to 6 C 6 Maximum Humidity 90% RH non condensing at 0 C 7 Induction Suppression Capability ma per 0 V upto maximum of ma. TECHNICAL SPECIFICATION FOR DIGITAL MEGGER (0KV) The instrument should be suitable for testing water filled stator of Generator, equipment in live switchyards etc., The instrument should performs automatic tests and measure Insulation Resistance, current, capacitance, Polarization Index, Step voltage tests, DAR & Dielectric Discharge, Ramp Test. Voltage selection 0V to KV in 0V steps, KV to KV,kV to 0kV in V steps, With Enable Voltage Lock Option Instrument should have provision to operate in both modes i.e. (i) In AC 0 V RMS, 0Hz mains (ii) Internal rechargeable Battery mode. The Battery supplied with tester should have minimum hour charging time, should be able to operate from main supply even with flat battery Rated analogue display resistance Minimum 00 KΩ to 0 TΩ. 6 Rated Digital Display Resistance 0 KΩ to0 TΩ. 7 Resistance range for each rated voltage shall be indicated in the offer. 8 Instrument should display direct reading of voltage across the test piece, PI value, and Dielectric discharge value when the test is in progress. 9 Instrument should display leakage measurement. 0 Short Circuit current 6 0KV Instrument should have 7mA or better Interference Rejection, plus instrument should have additional filter of 0, 0 and 00,00 seconds time constant selectable. Guard terminal should have at least % error guarding 00KΩ leakage with 00MΩ load for proper measurement upon high leakage current specimen. Insulation Resistance Measurement should be in Digital and Analogue with backlit display. Instrument should have capability for 0 hours logging as internal memory with date/time stamp Insulation resistance measurement range Digital display 0 KΩ to TΩ. Analogue display 00KΩ to 0TΩ. 7
8 6 Current measurement range 0.0 na to 6 ma 7 Voltage measurement range 0 to 660VDc or AC The Equipment should be able to perform the live data streaming along 8 with real time graphing, storage with the supplied software with the interface via USB Cable. 9 Digital and software filter should be available in the instrument to remove induced noise. 0 Safety should Conform to IEC 00 (99) Environmental Protection: Instrument should be rated to IP6 Instrument should have compliance to following Safety standards IEC00 (99), EN600 (99) to installation category IV, 600 V, 6. TECHNICAL SPECIFICATION FOR AC PRIMARY CURRENT INJECTION TEST SET (000A) Primary Injection Test System for testing for Current Transformer shall consist of a load unit with knob for adjusting current range. The load unit shall have following values given at supply voltage of 0V. 6 Injection up to 000A at minimum kva power shall be possible.current shall be stable regardless of load change or input fluctuations with accuracy of ±0.% of the value. The output transformer should have built in thermal cut out, and the primary side should be protected by a circuit breaker. Weight of the kit with better portability will be preferred. The weight and size shall be such that one person can handle the equipment at site for transportation from one place to other. Enclosure& Safety The primary injection test system shall include a rugged, shock proof enclosure equipped with handle and wheels for ease of transportation. The test system shall be certified to meet one or more of the following international safety standards. CE marking ( LVD 006/9/EC) EMC 00/08/EC ANSI C9., Safety Standard for Electrical and Electronic Equipment IEC 600, International Safety Standard 8
9 7. TECHNICAL SPECIFICATION FOR TEMPERATURE GUN The equipment should be of non contact thermometer of portable size and light weight so that it enables professionals to diagnose heating and ventilation problems and monitor the temperature of electrical motors and electrical panels without contact. Single point offset laser sighting Accuracy of ±% of reading Should have capability to hold temperature readings for minimum of sec. Should be able to display current and MAX measurements simultaneously. 6 Backlit display for poorly lit areas. Comfortable ergonomic handle with protective rubber boot for added 7 durability 8 Fitted carrying case 9 Temperature range from 0 to 00 C ( 0 to 9 F) 8. TECHNICAL SPECIFICATION FOR PORTABLE HYDROGEN LEAKAGE DETECTOR The instrument should be of detecting & pinpoint the gas leaks higher concentrations of hydrogen in the surrounding air. The detector should also has an audible alarm that warns option when a threshold is crossed and a headphone jack which allows you to connect earphones for more focused and productive working in loud or distracting environments. Flexible measurement probe for inaccessible places Optical and audible alarm with bar display for increasing and dangerous gas concentrations. Trend display showing maximum leakage 6 Rechargeable battery with charger 7 Measuring range 0 ppm to.0 Vol.% 8 Lower response 0 ppm 9 st alarm limit 00 ppm 0 nd alarm limit 0000 ppm 9
10 9. TECHNICAL SPECIFICATION FOR BATTERY DISCHARGE RESISTOR (0A) The instrument able to discharge the substation battery set of V//8/0/0V/80V DC system with facility of regulating discharge rate manually. The discharge current capacity of the kit shall be 0A The discharge current shall be user adjustable with sufficient amount of current selection switches/mcbs of discharge current rating A, A, 0A, 0A The discharge current can be settable at every voltage, subject to maximum current value. The kit shall display the running parameters during discharges like discharge currents (A), present Voltage (V) and temperature inside enclosure. 6 The Instrument should have internal cooling arrangement. 7 Test leads and necessary cables should be provided. The equipment shall be supplied with roller arrangement to transport 8 from one location to other easily and a user manual. 0. TECHNICAL SPECIFICATION FOR BATTERY DISCHARGE RESISTOR (00A) The instrument able to discharge the substation battery set of V//8/0/0V/80V DC system with facility of regulating discharge rate manually. The discharge current capacity of the kit shall be 00A The discharge current shall be user adjustable with sufficient amount of current selection switches of discharge current rating A, A, 0A, 0A The discharge current can be settable at every voltage, subject to maximum current value. The kit shall display the running parameters during discharges like discharge currents (A), present Voltage (V) and temperature inside enclosure. 6 The Instrument should have internal cooling arrangement. 7 Test leads and necessary cables should be provided. The equipment shall be supplied with roller arrangement to transport 8 from one location to other easily and a user manual. 0
11 . TECHNICAL SPECIFICATION FOR PHASE VARIAC (0A) Phase: Single Input: 0V, 0/60Hz AC ph. Output: 0 70V, 0/60Hz AC ph. Maximum output Current 0A Variac should be portable, enclosed air cooled Type 6 Excellent Regulation 7 High Efficiency 8 No Waveform Distortion 9 Silver Plated Commutator 0 Smooth & Linear Output Low magnetizing current. TECHNICAL SPECIFICATION FOR PHASE VARIAC (0A) Phase: Single Input: 0V, 0/60Hz AC ph. Output: 0 70V, 0/60Hz AC ph. Maximum output Current 0A Variac should be portable, enclosed air cooled Type 6 Excellent Regulation 7 High Efficiency 8 No Waveform Distortion 9 Silver Plated Commutator 0 Smooth & Linear Output Low magnetizing current
12 . TECHNICAL SPECIFICATION FOR MOTOR CHECKER The kit should be Digital portable and is used for quick on site checks of electric motor and other three phase machines The instruments should have separate operating modes to measure different types of faults like fully insulation, open circuits / loose connections, short circuits and rotor defects. Motor insulation is tested with a high voltage of 00V & 000V DC supplied by the instrument. Shall be capable of identifying open and short circuits / loose connections in a winding coil. Inductance of the winding with respect to different positions for rotor for detecting blow holes or cracks in the rotor bars. Simple operation, accurate & quick assessment of motor condition. 6 Battery operated with rechargeable batteries and AC adaptor for charging the same. 7 Measurement specifications 7. Insulation resistance 7. Resistance 7. Inductance 0 99M ohms at 00V DC 0 000M ohms at 000V DC 0 00milli ohms Resolution 0.M ohms 0.M ohms 0.0milli ohms 0 ohms 0.00ohms 0 0 ohms 0.0 ohms 0 00 ohms 0.0 ohms 0 mh 0 0mH 0 00mH 0 000mH 0.00mH 0.0mH 0.mH mh
13 . TECHNICAL SPECIFICATION FOR OIL SAMPLING BOTTLES Sampling bottle shall be made of Stainless steel 0 and 6 material Other accessories like nipples etc., shall also be made of stainless steel 0 grade. Gas tight valve to ensure there is no loss of gas during transport form site to lab for DGA test. Sampling bottles volume capacity shall be of liter. TECHNICAL SPECIFICATION FOR PROXIMITY DETECTOR The instrument should be rugged and reliable. The instrument should be capable of verifying the presence of voltage in low, medium and high voltage test applications up to 00 kv without contacting the energized conductor. Instrument should be provided with hot stick arrangement including hotstick. Voltage selection feature for verifying different voltage levels Alert with visual and loud audible indication when used in proximity of live source.
14 6. TECHNICAL SPECIFICATION FOR SINGLE PHASE RELAY TEST KIT The single phase Relay Testing equipment should be capable of secondary testing of protective relays, excitation curve plotting in CTs Current and voltage transformer ratio tests burden measurement for protective relays. Current source should provide 0 00 A AC. Voltage source should provide 0 0V AC or 0 0V DC, Auxiliary voltage source should provide 0 0 V DC 6 The test set should have Built in capacitors providing phase shift when testing directional protection, and a set of resistors which can be used to divide voltages. Output ports used to start external timers or relays like LBB or Auto reclosure relays. 7 Terminal for external start / stop of built in timer should be available. 8 Terminal for connecting serial impedance when testing nonlinear protection should be available. 9 Kit should be portable and easy to carry. 0 Timer range of sec with msec resolution 7. TECHNICAL SPECIFICATION FOR DIGITAL TACHOMETER The equipment should accurately measures rotational or surface speed as well as length. It should come with a LCD display that allows the user to easily read the measurement. It should have built in memory function that permits automatic storage of maximum, minimum, average values plus the last measurement displayed. The Tachometer should supplied with all the necessary accessories designed with optimal mechanical stability to ensure accurate, reliable, and repeatable measurements. Should be provided with mechanical adapters that accepts a variety of tips, as well as the surface speed wheel for contact rpm measurement.
15 6 Tachometer should also perform non contact measurement by using the infrared beam function. 8. TECHNICAL SPECIFICATION FOR KNEE POINT VOLTAGE TEST KIT Knee point tester should be suitable for outdoor applications involving application of AC high voltage to test objects, particularly knee point tests on CVTs and CTs at site. Should be provide Panel mounted controls and indicators with easy to read legend. Continuously variable output by one knob control. Kit should have the linear scaled kv meter and leakage ma meter. Fused overload protection should be provided for safety purpose. 6 7 Output voltage range should be minimum 0 kv with 00mA output current. Kit should be provided with minimum mtrs long mains cable and 6mtr long test leads. 9. TECHNICAL SPECIFICATION FOR MANUAL EARTH TESTER The Manual, hand driven Earth Tester is required for the measurement of Resistance of Earth under the following conditions. Measurement of Earth Resistance for large complex earthing systems. Accurate measurement of Earth Resistance in sub station site where variation of soil resistivity values will be large. Manual Earth Tester shall be robust, compact instrument designed for measuring electrode resistance.the instrument should have facility to measure Ground Resistance by standard Fall of Potential method using terminal methods by Current and Potential spikes Shall have silent Generator with collapsible handle Centrifugal Clutch (Governor) For Constant Output Voltage Check nut locking arrangement to prevent anti clockwise rotation 6 Wide and anti parallax mirror scale
16 Shall have anti magnetic,aluminum body with protected metallic flap over 7 glass window of scale Accurate, reliable and quick response for measurement of resistance of 8 earth 9 Accuracy shall confirm to IS : 9/ TECHNICAL SPECIFICATION FOR VACUUM BOTTLE TESTER The Vacuum bottle test kit should be able to ascertain whether or not the vacuum bottle is intact before putting back into service by giving optical Indication. Safety as per EMC standards. Voltage : 0kv to 60kv DC (User Selectable) Resolution: > 0 micro Amperes Ripple: Not more than % 6 Indications/Warnings while performing operation: When High voltage being applied. When Vacuum bottle is healthy When Vacuum bottle is Defective When test carried out for more than min When Test Interrupted 7 Protection: Overload Cut Out 8 Mains voltage 0 V AC +/ 0, 0 / 60 Hz 9 Accessories: The bidder should provide High voltage cable with large test clip connectors for easy & firm connection. 6
17 . TECHNICAL SPECIFICATION FOR SURGE ARRESTER TESTER Instrument should be used to check regularly the efficiency of the metal oxide surge arrester in service that are installed on the high voltage transmission and distribution networks. Instrument should measure the following parameters True RMS of the total current. Peak value of the total current. True RMS of the third harmonic. Temperature. Third harmonic range: 99.9μA for currents less than ma, or 999μA for higher currents with automatic range selection. Current Clip On Transformer Voltage measuring probe Current ratio: 000:. Ratio error from 0. ma to 0 ma: % ± 0.0μA. Load resistance: 7 Ohm. Frequency response: less than 0. db from 0 Hz to 0000 Hz. Tightening diameter: mm. Jaw opening: over mm. Connection: m screened cable, ending with a bayonet connector. Test probe for measuring the third harmonic of the system voltage, m long, with banana plugs for the connection to the PT secondary Nominal voltage: 00 V phase to phase (7.8 V phase to neutral). Maximum voltage: 00 V phase to phase. The cable should incorporate a resistor divider made of two resistors. 7
Insulation Testers and Earth Ground Testers
Insulation Testers and Earth Ground Testers With a 5000 V MegOhmMeter for industrial-strength insulation testing and a range of compact hand-held instruments, we offer a solution for every troubleshooting
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More information5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated
n CAT IV 600 V safety rating n Line supply or battery operated n Noise rejection (3mA or 4mA rms@200v and above) for use in high voltage substations or switchyards n 5mA output current provides fast charging
More informationMIT510/2, MIT520/2 and MIT1020/2
MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510/2 and MIT520/2) and 35 TΩ (MIT1020/2) CAT IV 600 V safety rating Automatic
More information79/26 Series III Multimeter
79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position
More informationAnalog Digital Multimeter with Insulation Resistance Measurement
RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,
More informationUSER MANUAL 600A AC Clamp Meter + NCV Model MA610
USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures
More informationAPPA 300 Series. The Most User-Friendly High Performance Multimeter
APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation
More informationDM-45 Digital Multimeter
INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital
More informationGAMMA 20 DIGITAL MULTIMETER
Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel
More informationMS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.
MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM
More information400Amp True RMS AC/DC Clamp Meter Model EX613
User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,
More informationRISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement
RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application
More informationMIT510, MIT520 and MIT1020
MIT510, MIT520 and MIT1020 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510 and MIT520) and 35 TΩ (MIT1020) Automatic insulation resistance tests Automatic
More informationTesters: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:
Table of Contents Testers: / Ohmmeters Insulation Measuring Instruments 51 METRAOHM 413 Article: M630A Digital Low-Resistance Measuring Instrument for Measuring Protective Conductors, Equipotential Bonding
More information1587/1577 Insulation Multimeters
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationUSER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More informationKeysight U1461A Insulation Multimeter/ U1453A Insulation Tester
Keysight U46A Insulation Multimeter/ U453A Insulation Tester Quick Start Guide Standard Accessories Included In Your Purchase Standard Accessories Included In Your Purchase The following accessories are
More informationAgilent 970-Series Handheld Multimeters Data Sheet
Agilent 970-Series Handheld Multimeters Data Sheet Benchtop features and performance with handheld convenience and price 3 1 /2and 4 1 /2 digits with dcv accuracy to 0.05% 1 khz to 100 khz frequency response
More informationNOTE: Fully read and understand this manual before using this Digital Multimeter.
ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and
More informationElectrical and HVAC Test Tools
Electrical and HVAC Test Tools The New Fluke 330 Series Clamp Meters New Fluke Products! 330 Series Clamp Meters 1520 MegOhmMeter 43B Power Quality Analyzer 170 Series Digital Multimeters 110 Series Digital
More informationAutoranging Multimeter Extech EX503
User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationDVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use
True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution
More informationSTS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000
STS 4000 Multifunction substation maintenance & commissioning test system for current, voltage and power transformers. Capacitance / Tan Delta diagnostic system with the optional module TD 5000. w w w.
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationAC/DC DIGITAL CLAMP METER OPERATION MANUAL
AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -
More informationMIT415 Insulation tester
MIT415 Insulation tester General features o 10V & 100V ESD testing o 25V, 50V, 250V & 500V additional ranges o Insulation testing up to 50Gohms (500V) o Continuity testing at 200mA or 20mA from 0.01ohms
More informationMIT515, MIT525, MIT1025
MIT515, MIT525, MIT1025 5-kV and 10-kV Insulation Resistance Testers n Industry best guard terminal accuracy n Compact and lightweight for easy transport and use PI, DAR, DD, SV and ramp test Unique dual
More informationMS2109A AC/DC Clamp Meter. User Manual. Contents
MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description
More informationIndeks: WMXXCMM60 Advanced Industrial Multimeter
CMM-60 Indeks: WMXXCMM60 Advanced Industrial Multimeter Description The CMM-60 multimeter allows you to record data thanks to the Trend Capture function of the built-in memory as well as the possibility
More informationEX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature
USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationFluke Clamp Meters Solutions for every need
Fluke Clamp Meters Solutions for every need 381 355 773 more solutions inside Clamp Meter selection chart Job functions Applications Recommended clamp Process Technician/ Automation Specialist Multiple
More informationMIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers
MIT400/2 Designed for electrical and industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilized insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationMS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More informationCompact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)
User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter
More informationSUBJECT TO CHANGE WITHOUT NOTICE
www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters ijunior / JUNIOR Current Transformers Analogue Panel Meters
More informationAgilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide
Agilent U1251B and U1252B Handheld Digital Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide
More informationINDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4
Micro-ohmmeter MH-10 Page 3 MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Earth resistance meter TL-5 Page 5 Indirect earth contact simulator MPC (5, 20, 50 A) Page 6 Trip time tester CR
More informationGAMMA 12 DIGITAL MULTIMETER
Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel
More informationCurrent Clamp. 210
Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display
More informationElectrical measurement technology. Re-invented.
Electrical measurement technology. Re-invented. Simpler and safer: the new era of measuring instruments from Testo. Testo revolutionizes electrical measuring technology. Nearly six decades of s instrumentation
More information600A Clamp Meters w/tightsight Display
V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766
More informationINSULATION TESTER SERIES
INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection guide IR4056-20
More informationModel 77 Series IV. Digital Multimeter. Users Manual
Model 77 Series IV Digital Multimeter Users Manual Model 77 Series IV Digital Multimeter The Fluke Model 77 Series IV is a battery-powered, average responding-rms indicating multimeter (hereafter "the
More informationFluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease
Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality
More informationMIT400/2 CAT IV Insulation testers
MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationFluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads
Fluke 345 Power Quality Clamp Meter Technical Data The ideal meter for commissioning and troubleshooting modern electrical loads With a bright color display to analyze the harmonic spectrum, a low-pass
More informationDVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding
BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual
More informationFluke 170 Series True-rms Digital Multimeters
TECHNICAL DATA Fluke 170 Series True-rms Digital Multimeters Fluke 170 Series DMMs are the industry-standard troubleshooting tools for electrical and electronic systems Fluke 170 Series digital multimeters
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free
User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting
More informationAgilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide
Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4
More informationFluke 370 FC Series true-rms wireless AC/DC clamp meters
Fluke 370 FC Series true-rms wireless AC/DC clamp meters Fluke 376 FC & 375 FC logging wireless AC/DC clamp meters, Fluke 374 FC wireless AC/DC clamp meter The Fluke 370 FC Series (376 FC, 375 FC, and
More informationModel ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com
Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...
More information270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual
270 manual.qxd 5/9/2005 3:04 PM Page 1 270 Digital Clamp-on Meter Instruction Manual 270 manual.qxd 5/9/2005 3:04 PM Page 2 TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3
More informationUser's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,
More informationUser's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations
More informationSubstation Preventive Maintenance
Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS
More information400Amp True RMS AC Clamp Meter + NCV
User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationUSER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current, Resistance,
More informationAgilent U1253B True RMS OLED Multimeter. Quick Start Guide
Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4
More informationTESTING & MEASUREMENT
www.greenlee.com TESTING & MEASUREMENT Safe. Accurate. Reliable. Expect nothing but the best from Greenlee electric test and measurement equipment. Backed by a limited lifetime warranty and designed to
More informationAC/DC CLAMP METER CM4371, CM4373
AC/DC CLAMP METER CM4371, CM4373 Field measuring instruments CM4371 : 600 A AC/DC CM4373 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters
More information0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES Capacitance Meter
TES-1500 Capacitance 0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES-2620 TRMS Multimeter TES-2700 TES-2712 LCR Multimeter 3-3/4 Digital LCD with bar-graph
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) MIT515, MIT525, MIT1025 MIT515, MIT525, MIT1025 5-kV and 10-kV Insulation Resistance Testers n Industry best guard terminal
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationDL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter
DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationFluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease
Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality
More informationFluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents
Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationMIT400 CAT IV Industrial Insulation Testers
MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms
More informationSafety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.
9305 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates
More informationElectrical Test & Measurement Equipment
Appliance Tester MI 3309 Delta GT Earth Bond Test 200 ma Insulation resistance (250 VDC, 500 VDC) Insulation resistance of isolated accessible conductive parts Substitute leakage current (up to 19.99mA
More informationMIT400 CAT IV Industrial Insulation Testers
MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand
More informationUSER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at
USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device
More information1507/1503. Insulation Testers. Users Manual
1507/1503 Insulation Testers 1507/1503 Insulation Testers Introduction The Fluke model 1507 and model 1503 are battery-powered insulation testers (hereafter, "the Tester"). Although this manual describes
More informationDigital multimeter selection guide
Digital multimeter selection guide Advanced meters Wireless meters General purpose 87 V 289 287 233 3000 FC 179 Basic features Counts 20000 50000 50000 6000 6000 6000 -rms readings ac ac+dc ac+dc ac ac
More informationEX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC
USER MANUAL True RMS Digital Multimeters EX360 Series EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC EX365 True RMS DMM with 10A AC/DC Current Additional User Manual
More informationInsulation resistance testing. A complete solution for every person.
Insulation resistance testing. A complete solution for every person. Insulation resistance. The latest test tools from the testing experts. You asked. We responded. Now you have more insulation testing
More informationContents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5
Measuring and testing equipments P 6 P.6.01 GB for substations Micro-ohmmeter MH-10 Page 3 Mega-ohmmeter MI (5, 10, 15, 20 kv) Page 4 MD (5 kv) Page 4 Indirect earth contact simulator TL-5 Page 5 Indirect
More informationAC/DC Current Oscilloscope Probe Model SL261
AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationDIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.
DIGITAL MULTIMETERS Model M-1700 Model M-2775 Frequency to 20MHz Diode and Transistor Test AC/DC Current to 10A Three Way Overload Protection Extra Large 1 display test Data Hold Frequency to 20MHz Transistor
More informationE Series 9.00 (1/2) E series
Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationRS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.
3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER Field measuring instruments 2001 Support efficient data collection RS-232C communication All HiTESTERs For Personal
More informationMeasure voltage without test leads. Product Highlights
Measure voltage without test leads Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. + Without opening covers or removing wire nuts. On wires up to AWG 4/0
More informationAX-C Introduction. 2. Safety Information
AX-C708 1. Introduction Read Safety Information before using the meter. ProcessMeter ( referred to as the meter )is a handheld, battery-operated tool for measuring electrical parameters. It has all the
More informationDM-46 Instruction Manual
Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11
More informationSafety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software
Safety through Competence Short Form Catalogue Measuring Testing Controlling World Class Hardware and Software MAVOLOG 20P Test Instrument for Monitoring Voltage Quality Electrical Engineering, Maintenance,
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More information