Delta Style Room Humidity Units
|
|
- Emory Chandler
- 5 years ago
- Views:
Transcription
1 B8 Delta Style Room Humidity Units Rev. 12/14/17 Features & Options l Low Profile Delta Style Enclosure with Optional Display l Humidity Only or Temperature/Humidity Combo l 2% and 3% RH Accuracies l Optional Communications Jack l User Adjustable Toggle Rate Between Temp & Humidity Display l Wide Selection of Temperature Sensing Elements l Full-range Temperature Compensation of RH Signal l Five Year Warranty The Delta Style room units are available as Humidity Only sensors or as Combination temperature and humidity sensors. They feature an optional display with a user adjustable toggle rate between humidity and temperature and can display in either C or F. The unit is available with the entire line of BAPI temperature sensors. If a temperature transmitter and humidity transmitter are desired, then see the X-Combo Unit on pages B10-11 of this section. Delta Style Enclosures with and without Display Specifications Power: 10 to 35 VDC (0 to 5 VDC or 4 to 20 ma Outputs) 15 to 40 VDC (0 to 10 VDC Output) 12 to 24 VAC (0 to 5 VDC Output) 15 to 28 VAC (0 to 10 VDC Output) Note: If AC power is used, it must be shielded from the signal wiring Power Consumption: 22 ma max. DC (0 to 5 VDC or 4 to 20 ma Outputs) 6 ma max DC (0 to 10 VDC Output) 0.53 VA max. AC (0 to 5 VDC Output) 0.14 VA max. AC (0 to10 VDC Output) Sensing Elements: Temperature - Thermistor or RTD (See Sensors section for specs.) Humidity - Capacitive Type, ±2% or 25 C (77 F), 20 to 80%RH %RH Calibration Adjustment: ±5% POT Wiring: 2 to 3 pair of 16 to 22 AWG* Mounting: 2 x4 J-box or drywall mount - screws provided Environmental Operation Range: Temp: 32 to 122 o F (0 to 50 o C) Humidity: 5 to 95%, non-condensing Material & Rating: ABS Plastic, UL94 HB Agency: RoHS and CE *BAPI recommends that you do not run wiring for the room units in the same conduit as line voltage wiring or with wiring used to supply highly inductive loads such as motors, generators and coils.
2 Delta Style Room Humidity Units B9 Use the Option Selection Guide below to create your custom part number. Replace the number and parenthesis with the designator for each selection. Skip the designator and dashes for optional selections that are not required in your configuration. Delta Style Room Humidity Sensor Option Selection Guide: BA/ ( #1 ) - ( #2 ) - ( #3 ) - ( #4 ) - ( #5 ) #1: Temperature Sensor (optional) 1K[375]...1K Platinum RTD (375 curve) 1K...1K Platinum RTD (385 curve) 1.8K...1.8K Thermistor 3K...3K Thermistor 10K K-2 Thermistor 10K K-3 Thermistor 10K-3[11K]...10K-3[11K] Thermistor 20K...20K Thermistor #2: Humidity Output (required) H200...Interchangeable 4 to 20mA or 0 to 5V Output H to 10 Output H to 10V Output #3: Display and Indication (required) RD...With Display R...No Display #4: Communication Jack (optional) C35L mm Phono Style Jack Additional options are available for these units but not shown in this Selection Guide. Contact your BAPI representative for the complete list of options. Submittal sheets without List Prices can be downloaded from our website at Example Number: BA/ ( 10K-2 ) - ( H200 ) - ( RD ) - ( C35L ) - ( ) Actual Number (with parenthesis removed): BA/10K-2-H200-RD-C35L Description: 10K-2 Thermistor Temperature Sensor, 4 to 20mA or 0 to 5V Interchangeable Humidity Output, Delta Style Room Enclosure with Display, 3.5mm Phono Style Comm. Jack Your Number: BA/
3 B20 Duct Units Features & Options l 10 Points of Calibration from 10 to 90% RH l Humidity Only or Temp./Humidity Combination l Replaceable Stainless Steel Filter l Green Power Indication LED on BAPI-Box Crossover Units l 2% and 3% RH Accuracies Humidity control is an important aspect of any climate control system. Therefore, humidity sensors must be both accurate and dependable. BAPI s humidity transmitters are calibrated at 10 points from 10 to 90% RH for accuracy, eliminating field calibration. The Duct Units are also extremely dependable, featuring two of the most watertight enclosures available today. The BAPI-Box and BAPI-Box Crossover Enclosures are made of UV-resistant polycarbonate and carry an IP66 rating. The BAPI-Box is only available for units with a temperature transmitter and a humidity transmitter. BAPI-Box Crossover Rev. 03/16/18 BAPI-Box (only available for units with a temperature transmitter and a humidity transmitter) The BAPI-Box Crossover Enclosure The BAPI-Box Crossover features a hinged cover with thumb latch for easy termination. A pierceable knockout plug is available for the open port. See the Accessories section for more info. (Unit shown with knockplug plug sold separately.) Specifications Power and Consumption: 10 to 35 VDC, 22 ma max. (for units with 0 to 5 VDC or 4 to 20 ma Humidity Outputs) 15 to 35 VDC, 6 ma max. (for units with 0 to 10 VDC Humidity Output) 12 to 27 VAC, 0.53 VA max. (for units with 0 to 5 VDC Humidity Outputs) 15 to 27 VAC, 0.14 VA max. (for units with 0 to 10 VDC Humidity Output) Enclosure Dimensions: H x W x D BAPI-Box Crossover: x 2.2 x 1.9 (79 x 56 x 49mm) BAPI-Box...5 x 4.1 x 2.5 (127 x 104 x 63.5mm) (For enclosure dimension drawings, turn to the end of the section.) Sensor: Humidity: Capacitive 2% or 3%RH (10 to 90% 23 C) Temperature: Thermistor or RTD (See Sensors section for specs) Enclosure Rating: BAPI-Box Crossover: IP10, NEMA 1 (IP44 with knockout plug) BAPI-Box: IP66, NEMA 4X Enclosure Material: UV-res. Polycarbonate, UL 94, V-0 Environmental Operation Range: Temp: -40 to 158 F (-40 to 70 C) Humidity: 0% to 100% RH Fully Temperature Compensated
4 Duct Units B21 Use the Option Selection Guide below to create your custom part number. Replace the number and parenthesis with the designator for each selection. Skip the designator and dashes for optional selections that are not required in your configuration. Duct Humidity Sensor Option Selection Guide BA/ ( #1 ) - ( #2 ) - ( #3 ) #1: Temperature Sensor or Transmitter (optional) 1.8K...1.8K Thermistor 3K...3K Thermistor 10K K-2 Thermistor 10K K-3 Thermistor 10K-3[11K]...10K-3[11K] Thermistor 20K...20K Thermistor 1K[375]...1K Platinum RTD (375 curve) 1K[NI]...1K Ω Nickel RTD 1K...1K Platinum RTD (385 curve) Temperature Transmitters below require a BAPI-Box Enclosure T1K[32 TO 212F]...1K Plat. RTD Transmitter, 4 to 20 ma Output, 32 to 212 F Range T1K[20 TO 120F]...1K Plat. RTD Transmitter, 4 to 20 ma Output, 20 to 120 F Range T1K[0 TO 100F]...1K Plat. RTD Transmitter, 4 to 20 ma Output, 0 to 100 F Range T1K[0 TO 100C]...1K Plat. RTD Transmitter, 4 to 20 ma Output, 0 to 100 C Range T1K[-7 TO 49C]...1K Plat. RTD Transmitter, 4 to 20 ma Output, -7 to 49 C Range T1K[-18 TO 38C]...1K Plat. RTD Transmitter, 4 to 20 ma Output, -18 to 38 C Range Matched Transmitters are also available. Contact your BAPI representative for ordering. #2: Humidity Output (required) H200...±2% Humidity Transmitter with Interchangeable Output of 0 to 5 V or 4 to 20 ma H210...±2% Humidity Transmitter with 0 to 10 V Output H212...±2% Humidity Transmitter with 2 to 10 V Output H300...±3% Humidity Transmitter with Interchangeable Output of 0 to 5 V or 4 to 20 ma H310...±3% Humidity Transmitter with 0 to 10 V Output H312...±3% Humidity Transmitter with 2 to 10 V Output #3: Enclosure Style (required) D-BBX...BAPI-Box Crossover (IP10, NEMA 1) D-BB...BAPI-Box (for units with a humidity and temperature transmitter only) Additional options are available for these units but not shown in this Selection Guide. Contact your BAPI representative for the complete list of options. Submittal sheets without List Prices can be downloaded from our website at Example Number: BA/( 10K-2 ) - ( H200 ) - ( D-BBX ) Actual Number (with parenthesis removed): BA/10K-2-H200-D-BBX Description: 10K-2 Thermistor, 0 to 5V or 4 to 20mA Humidity Output, BAPI-Box Crossover IP10- rated Enclosure. Your Number: BA/
5 B18 Outside Air Units Rev. 07/31/17 Features & Options l 10 Points of Calibration from 10 to 90%RH l Humidity Only or Temp./Humidity Combination l Replaceable Filter l 2% and 3%RH Accuracies l BAPI-Box 2 or BAPI-Box Enclosure Styles l Wide Selection of Temperature Sensing Elements Humidity control is an important aspect of any climate control system. Therefore, humidity sensors must be both accurate and dependable. BAPI s humidity transmitters are calibrated at 10 points from 10 to 90% RH for accuracy, eliminating field calibration. The Outside Air Units are also extremely dependable, featuring two of the most watertight enclosures available today. The BAPI-Box and BAPI-Box 2 are made of UV-resistant polycarbonate and carry an IP66 rating. The BAPI-Box is only available for units with a temperature transmitter and a humidity transmitter. BAPI-Box 2 Enclosure Weather Shade External temperature, humidity and air quality sensors are affected by radiant heat from the surfaces of buildings and parking lots. The BAPI Weather Shade effectively blocks the radiant heat, improving the accuracy of the sensor. Specifications Power and Consumption: 10 to 35 VDC, 22 ma max. (for units with 0 to 5 VDC or 4 to 20 ma Humidity Outputs) 15 to 35 VDC, 6 ma max. (for units with 0 to 10 VDC Humidity Output) 12 to 27 VAC, 0.53 VA max. (for units with 0 to 5 VDC Humidity Outputs) 15 to 27 VAC, 0.14 VA max. (for units with 0 to 10 VDC Humidity Output) Enclosure Dimensions: H x W x D BAPI-Box...5 x 4.1 x 2.5 (127 x 104 x 63.5mm) BAPI-Box 2: x 2.8 x 2.35 (125 x 71.6 x 60mm) (For enclosure dimension drawings, turn to the end of the section.) Sensor: Humidity: Capacitive 2% or 3%RH (10 to 90% 23 C) Temperature: Thermistor or RTD (See Sensors section for specs) (See Accessories for more info.) BAPI-Box Enclosure (only available for units with a humidity and temperature transmitter) Enclosure Rating: IP66, NEMA 4 Enclosure Material: UV-res. Polycarbonate, UL 94, V-0 Environmental Operation Range: Temp: -40 to 158 F (-40 to 70 C) Humidity: 0% to 100% RH Fully Temperature Compensated
6 Outside Air Units B19 Use the Option Selection Guide below to create your custom part number. Replace the number and parenthesis with the designator for each selection. Skip the designator and dashes for optional selections that are not required in your configuration. Outside Air Humidity Sensor Option Selection Guide BA/ ( #1 ) - ( #2 ) - ( #3 ) #1: Temperature Sensor or Transmitter (optional) 1.8K...1.8K Thermistor 3K...3K Thermistor 10K K-2 Thermistor 10K K-3 Thermistor 10K-3[11K]...10K-3[11K] Thermistor 20K...20K Thermistor 1K[375]...1K Platinum RTD (375 curve) 1K[NI]...1K Ω Nickel RTD 1K...1K Platinum RTD (385 curve) Temperature Transmitters below require a BAPI-Box Enclosure T1K[32 TO 212F]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, 32 to 212 F Range T1K[20 TO 120F]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, 20 to 120 F Range T1K[0 TO 100F]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, 0 to 100 F Range T1K[0 TO 100C]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, 0 to 100 C Range T1K[-7 TO 49C]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, -7 to 49 C Range T1K[-18 TO 38C]... 1K Plat. RTD Transmitter, 4 to 20 ma Output, -18 to 38 C Range Matched Transmitters are also available. Contact your BAPI representative for ordering. #2: Humidity Output (required) H200...±2% Humidity Transmitter with Interchangeable Output of 0 to 5 V or 4 to 20 ma H210...±2% Humidity Transmitter with 0 to 10 V Output H212...±2% Humidity Transmitter with 2 to 10 V Output H300...±3% Humidity Transmitter with Interchangeable Output of 0 to 5 V or 4 to 20 ma H310...±3% Humidity Transmitter with 0 to 10 V Output H312...±3% Humidity Transmitter with 2 to 10 V Output #3: Enclosure Style (required) O-BB2...BAPI-Box 2 (IP66, NEMA 4X) O-BB... BAPI-Box (for units with a humidity and temp transmitter only) (IP66, NEMA 4X) Additional options are available for these units but not shown in this Selection Guide. Contact your BAPI representative for the complete list of options. Submittal sheets without List Prices can be downloaded from our website at Example Number: BA/( 10K-2 ) - ( H200 ) - ( O-BB2 ) Actual Number (with parenthesis removed): BA/10K-2-H200-O-BB2 Description: 10K-2 Thermistor, 0 to 5V or 4 to 20mA Humidity Output, BAPI-Box 2 Enclosure. Your Number: BA/
BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions
Overview and Identification The BAPI-Stat 4 X-Combo () Room Unit features 4 output channels and optional local indication of temperature and humidity. Additional options include Temperature Setpoint, Humidity
More information2018 PRODUCT LINE. Changing the way you think about sensors... BUILDING AUTOMATION PRODUCTS INC.
BUILDING AUTOMATION PRODUCTS INC. 2018 PRODUCT LINE TEMPERATURE HUMIDITY PRESSURE AIR QUALITY ACCESSORIES WIRELESS Changing the way you think about sensors... THE BAPI DIFFERENCE BAPI headquarters in Gays
More informationWireless HVAC Sensors
Rev. 02/15/11 Wireless Overview l 8 Year Battery Life l Temperature Only or Temperature/Humidity Combination l 100 Foot In-Building Range, Extendable to 1,000 Feet with Repeater* l Transmitted signals
More informationPrecision humidity control/sensing
HIGH ACCURACY HUMIDITY TRANSMITTER HAH Series Precision humidity control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% or 2% Room, Duct, or Outside models
More informationPrecision humidity control/sensing
RELATIVE HUMIDITY TRANSMITTER RH Series Precision humidity control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 2%, 3%, & 5% Choice of precision temperature
More informationRH/RHT Series. Relative Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. Features
GE Sensing & Inspection Technologies RH/RHT Series Relative Humidity and Temperature Transmitters The Relative Humidity (RH) and Temperature transmitters are designed for continuous monitoring of relative
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationFST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL
FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL 20020628 CONTENTS DESCRIPTION... 3 OPERATION... 4 Power Supply...4 Output Range...4 Temperature Operating Range and Temperature Limits...4
More informationHumidity Sensor/Transmitter Assembly
Humidity Sensor/Transmitter Assembly Wall/Duct Space Outside Air (OSA) Overview Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing
More informationHUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER
HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER A. GENERAL DESCRIPTION The Tegam Model RH is a relative humidity transmitter; the Model RHT includes a temperature
More informationHT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions
HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Model HT2 is a 2-wire temperature
More informationWireless Temp/Setpoint & Override Room Transmitter
Overview The BAPI Wireless Combination Transmitter measures the room temperature and relative humidity and transmits the data at 418MHz or 433MHz RF to a receiver. Temperature setpoint and override button
More informationWireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions
Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationType EXT with cable, probe sold
standard signal FF-GLT-Series Description Type INT for duct mounting, probe installed Type EXT with cable, probe sold Type AF for wall mounting, probe sold Characteristic features Standard signal 0...
More informationRTD Input Module. Product Specifications and Installation Data 1 DESCRIPTION 2 INSTALLATION
RTD Input Module Product Specifications and Installation Data 1 DESCRIPTION The HE693RTD720 Input Modules allow RTD temperature sensors to be directly connected to the PLC without external signal processing
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationTOP VIEW. 6.75" (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285" (185mm) Battery Positive Terminal SIDE VIEW. 6.12" (155.
Installation and Operation Instructions RR2552 Spread Spectrum Repeater TOP VIEW 6.75" (171.5mm) Network ID Selector Ø0.190 (4 PLCS.) Data Link LED 3.5" 4.72" (88.9mm) (119.89mm) Active LED Battery Positive
More informationMODEL DESCRIPTION PAGE
MONITORING Veris Industries offers a complete line of sensors for commercial/industrial relative humidity monitoring applications. Our sensors include a factory-calibrated humidity sensing element, fully
More informationRelative Humidity & Temperature Transmitters
Relative Humidity & Temperature Transmitters High Temperature Models up to 150 C (300 F) Series 740 and 741 EMC Immunity to EN 50082-1 Series 741: 2-Wire 4-20mA Ouput Series 740: User- Selectable Signals
More informationWireless Analog Output Modules
Overview and Product Identification Wireless Analog s Analog s receive data from a BAPI 418 MHz receiver or 900 MHz receiver through a four-wire RS 485 bus. Up to 127 different Analog s can be connected
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual
T0213 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0213 transmitter
More informationH7625B, H7626B, H7635B,C H7636B, H7655B, H7656B
H765B, H766B, H7635B,C H7636B, H7655B, H7656B DUCT-MOUNT AND OUTDOOR-MOUNT HUMIDITY/ TEMPERATURE SENSORS INSTALLATI INSTRUCTIS APPLICATI The H76XXB Duct-Mount and H76XXC Outdoor-Mount Humidity/Temperature
More informationTS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs
European Electronic Controls Catalogue Catalogue Section A Product Bulletin TS-9100 Issue Date 09 2000 TS-9100 Electronic Sensors and Transducers I ntroduction The TS-9100 series of electronic temperature
More informationSEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER
RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION
More informationTxBlock-USB Transmitter
Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is
More informationInstruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output
www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationVELTRON II Microprocessor Based Pressure & Flow Smart
VELTRON II Microprocessor Based Pressure & Flow Smart Transmitter Accurate airflow measurement for demanding applications Precision Airflow Measurement An ONICON Brand VELTRON II with Automatic Zeroing
More informationFor HVAC monitoring & control, the pharmaceutical industry, building management systems, the paper industry, research, museums and many others.
HUMIDITY PROBES HygroClip2 probe The HygroClip2 is a completely new type of probe in a class of it's own in terms of accuracy and performance. Thanks to the new AirChip3000 technology, it also boasts a
More informationModus M Series. General Eastern Differential Pressure Transmitters. GE Sensing
The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationNuclear Qualified Weed Instrument Model N7030 RTD and N7040 Thermocouple Analog Temperature Transmitter
DELIVERING CRITICAL MEASUREMENTS Nuclear Qualified Weed Instrument Model N7030 RTD and N7040 Thermocouple Analog Temperature Transmitter True Analog Transmitter Qualified per IEEE 323 Class 1E Mild Environment
More informationSEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER
UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationTechnical Information itemp TMT180
TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application
More informationPaperless Recorder PR20
Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationSAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force
4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24
More informationType Overview. Technical Data. Outdoor Humidity, Temperature Sensor
Outdoor Humidity, Temperature Sensor ±2% accurate humidity and temperature sensor for outdoor applications. Temperature is available with dual active 4 to 20 ma outputs or passive only for temperature.
More informationModel Q40CT. System Features. Toroidal Conductivity Monitor...
ATI s Model Q40CT toroidal conductivity system is designed for on-line monitoring of chemically aggressive process solutions. This blind, analog version is ideally suited for applications where reliable
More informationAH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models AH71, AH72, and AH73 are
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS
Zlinx Wireless Modbus I/O-0712ds page 1/5 Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII
More informationOutput Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V
Outdoor Humidity, Temperature Sensor ±2% accurate humidity and temperature sensor for outdoor applications. Temperature is available with dual active 4 to 20 ma outputs or passive only for temperature.
More informationTemperature Controllers E5 J
Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationMultifunction Intelligent 4-wire Isolated Signal Conditioner
Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationSAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke
s A6V10628469 ACVATIX Electromotoric actuators for valves SAY..P.. with a 15 mm stroke SAY31P03 Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationSAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke
s A6V10628469 ACVATIX Electromotoric actuators for VPI46 SAY..P.. with a 15 mm stroke Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20
More informationPolyGard Digital Transmitter DGC DT-02
PolyGard Digital Transmitter DGC DT-02 Description LON interoperable digital gas transmitter to monitor toxic and combustible gases and vapors in the ambient air. The complete monitoring and alarm tripping
More informationInstallation Instructions Space Temperature Transmitter
Installation Instructions Space Temperature Transmitter Catalog Number(s) 1414-CTZ03PBRAA, 1414-CTD03PBRAA, 1414-CTO03PBRAA, 1414-CTS03PBRAA, 1414-CTT03PBRAA, 1414-ITS03PBRAA, 1414-ITT03SBRAA, 1414-ITZ02GBRAA,
More informationSM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:
/ Flow / Variable Area SM-5 Plastic Flowmeters as per the Variable Area Principle Description: Features / For every industrial application / For fluid and gaseous media / Simple and robust design with
More informationNon-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
More informationSELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx
SELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx 2 INDUSTRIAL TRANSMITTERS of Txxxx, Pxxxx family: MEASURED VALUE /OUTPUT 4 to 20mA 0 to 10V RS485 RS232 Ethernet temperature
More informationECP-103 Series. ECP-103 Series. 10-Point Free Programmable Controller. Applications. Features
ECP-103 Series 10-Point Free Programmable Controller Applications Control of terminal units such as VAV, FCU, UV and HPU as well as control for chilled ceiling applications. Control of many other types
More informationH7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors
H765A, H765A, H766A, H766A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS INSTALLATI INSTRUCTIS APPLICATI The H765A, H766A, H765A and H766A Wall-Mount Humidity/Temperature Sensors are universal
More informationNon-Spring Return DuraDrive Modulating Actuator
MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries
More informationDP2500 DP0100 DP0250 Differential Pressure Transmitter
PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air
More informationOutput Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W
Duct Sensor Humidity / Temperature Active sensor (4...20 ma) for measuring the relative or absolute humidity and temperature in duct applications. Instead of the humidity signal, the enthalpy or the dewpoint
More informationNEUROLOGIC RESEARCH CORPORATION
NEUROLOGIC RESEARCH CORPORATION MODEL 1100A INDUSTRIAL TEMPERATURE NETWORK TRANSMITTER High temperature/sealed sensing element construction. Digitally calibrated for high accuracy Electronics are sealed
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationHLC-1000 High-limit Humidity Control
FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification
More informationTwo-Wire Programmable Transmitter for:
TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationHT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models HT880 and HT885 are 2-wire temperature
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual
T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter
More informationS E C T I O N 8 : H VAC S E N S O R S
S E C T I O N 8 : H VAC S E N S O R S Complete range of sensors/transmitter assemblies made for easy installation, high reliability, and compatibility with almost any Building Automation System Accurate
More informationSeries HT-9000 Electronic Humidity Transmitter. Features and Benefits. HT-9000 Electronic Humidity Transmitter
Series HT-9000 lectronic idity Transmitter uropean lectronic Controls Catalogue Catalogue Section A Product Bulletin HT-9000 Issue Date 06 2001 I ntroduction The Johnson Controls humidity transmitter is
More informationSOLID STATE HOURMETERS & COUNTERS 700 SERIES APPLICATIONS A wide variety of industrial and commercial applications, including scheduled maintenance, warranty and leasing for medical equipment, transport
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIsolated RTD Modules Product Specifications and Installation Data
Isolated RTD Modules Product Specifications and Installation Data 1 DESCRIPTION The Horner APG Isolated Resistance Temperature Detector (RTD) Input Modules allow RTD temperature sensors to be directly
More informationH7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors
H765A, H7635A, H766A, H7636A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATI The H765A, H766A, H7635A and H7636A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity
More informationSAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke
s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10
More informationC1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications
Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual
T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter
More informationSeries 10-ZSE30A(F)/10-ISE30A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H
More informationWhen it comes to humidity, we re not perfect. Just better.
HUMIDITY/TEMPERATURE HUMIDITY/TEMP Humidity (AQW) Series 44 Slimline Humidity (HR) Series 46 Duct Mount Humidity (HD) Series 48 Outside Air Humidity (HO) Series 50 Wireless Outside Air (WO) Series 52 Surface
More informationMODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System
Model AWRMS TM 200 Automated Winding Resistance Measurement System Currents up to 200A for performing Winding Resistance and Heat Run Tests. Heavy Duty Protection Circuit. Accuracy with Four Wire Measurements
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationHART Compatible Intelligent 2-wire In-head Transmitters
HART Compatible Intelligent 2-wire In-head Transmitters Actual size MESO-H is a Smart and universal 2-wire Inhead transmitter for temperature and other measurement applications. MESO-HX is the Intrinsic
More informationSignet 2750 DryLoc ph/orp Sensor Electronics
Signet 2750 DryLoc ph/ Sensor Electronics Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or operation In-line 2750 Submersible
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationGENERAL PURPOSE RELAYS
CONTROL LOGIC GENERAL PURPOSE RELAYS GR c3controls offers a full line of General Purpose Relays ( plug-in relays), perfect for your control logic applications. Quick and economical to install, our relays
More informationQPM Series Indoor Air Quality Duct Sensors
Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationE-BUS Digital Room Sensor Technical Guide
E-BUS Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Dimensions... 5 Environmental Requirements...
More information