Price list 2018 Devices

Size: px
Start display at page:

Download "Price list 2018 Devices"

Transcription

1 Price list 2018 Devices

2 Product range Chapter Chapter name System overview Page 1 1 Heat cost allocator - Q caloric New installation - Standard exchange - Conversion installation (P2 + AL2) New installation - Standard exchange - Conversion installation (P3 + AL2) Article-Number-Matrix 8 2 Compact heat meters - Q heat Screw-type meters (QDS) Screw-type meters (QDS) incl. radio add-on modul Screw-type meters (QDS) - integrated communication M-Bus Measuring capsule (IST) Measuring capsule (IST) incl. radio add-on modul Screw-type meters (US) - ultrasonic Screw-type meters (US) - ultrasonic incl. radio add-on modul Article-Number-Matrix 18 3 Split heat meters - Q heat split Split heat meters complete - Ultrasonic flow sensors (thread) Split heat meters complete - Ultrasonic flow sensors (flange) Split heat meters complete - Woltman flow sensors (flange) Article-Number-Matrix Split heat meters Calculator units 27 4 Water meters - Q water Electronic screw-type water meters Mechanical screw-type water meters incl. radio add-on modul Mechanical screw-type water meters Electronic measuring capsule water meters Mechanical measuring capsule water meters incl. radio add-on modul Mechanical measuring capsule water meters Electronic valve and bath meters 44 5 Smoke detector - Q smoke Smoke detector standalone Smoke detector radio 49 6 Further system components data readout Q walk-by / Q AMR Radio add-on modules for mechnical water meters Radio add-on modules for heat meters Radio impulse adapter 55 subject to error and change, previous price lists lose their validity

3 Product range Chapter Chapter name Page 7 Further system components data readout Q AMR Networknodes Gateways Overview of tariffs Gateway Service Description (GSD) Solution package for small Q AMR systems 57 8 Further system components data readout Q M-Bus Add-on modules for water meters Add-on modules for heat meters Impulse input module 60 9 General terms and conditions General terms and conditions 61 subject to error and change, previous price lists lose their validity

4 Our systems. Ideal for every property. AMR walk-by M-Bus Q AMR provides automated meter reading for buildings of all sizes. The values are transmitted securely and reliably to the service provider using a GSM phone network or broadband cable. The data is available immediately for the invoicing of heating and operating costs as well as the display of statistics for the housing industry and consumption patterns. Q walk-by operates without the need to enter flats or offices. Instead the meter reading service receives the data simply, fast and securely in the publicly accessible areas of the building. Where installations are not too extensive the data can even be recorded from outside the building. Q M-Bus is based on the European meter bus industrial standard. The main features of this wired remote data reading system are a high level of flexibility and secure data transmission. It is especially recommended for use in buildings where the wireless transmission of data is less suitable because of the design of the building opto basic All devices in the Q opto series have a close-range optical interface (IrDA). With the IrDA interface the data exchange is implemented across short distances by infrared light. Q opto enables the reader to compare current consumption values with the previous year s data. Q basic covers devices which are read individually and directly by visual contact. The measuring results are recorded manually by the reader. Comparison transmission features S-Mode (mode switch possible with Q suite 5) parallel transmission of telegrams Q walk-by Q AMR every 128 seconds every 4 hours 10 hours a day ( hrs) 24 hours a day monthly: 4 read-out days from the 1st of each month 7 days a week or: 48 days after the scheduled day 365 days a year delayed transmission possible (offset) transmission-free days possible read-out requirements: Q log current ACT46 Q node 5 + Q gateway 5 C-Mode (mode switch possible with Q suite 5) parallel transmission of telegrams Q walk-by Q AMR enhanced transmission performance enhanced transmission performance (max. 10 dbm) (max. 10 dbm) every 112 seconds every 7,5 minutes 10 hours a day ( hrs) 24 hours a day 365 days a year 365 days a year read-out requirements: Q log current ACT46 Q node 5.5 (a. Q3/2018) + Q gateway 5 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT page 1

5 1 Heat cost allocators Electronic heat cost allocators are radiator-mounted devices capable of measuring its heat output and storing the data acquired. A distinction is made between one-sensor and two-sensor heat cost allocators. One-sensor devices record the radiator temperature and assume a fixed room temperature for consumption calculation. In contrast, two-sensor devices record both the radiator and the room temperatures. Both device types can be used with standard heating systems, with low-temperature heating systems twosensor devices are mandatory or more suitable. Both device types can display and/or store different values, e.g. the cumulated value at a selectable due date or end-of-the-month values and a fault message in case of an error. There are different systems: Q basic is readout visually and noted manually. With Q opto, the devices have an integrated IrDA interface and are readout with a respective device directly at the radiator. Then there are the devices and systems that are readout via radio. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 3

6 1 Heat cost allocators 1.1 Q caloric 5.5 (P2 + AL2) The heat cost allocators listed below are for installation in new systems (no attachment parts available on the radiator), for standard exchange in systems with existing QUNDIS devices Q caloric 5, 201 and 202 (attachment parts available on the radiator) and for conversion installation in systems with external brands e.g. evaporator (attachment parts partly available). New installation: suitable installation plate has to be ordered Conversion installation: suitable installation plate has to be ordered Standard exchange: installation plate available EN 834-conform one-sensor or two-sensor heat cost allocator, storing of annual values with checksum, electromechanical contact for detecting device opening (e.g. in the case of manipulation), programmable due date and seal already pre-mounted in the housing, for average temperatures ranges from 55 C or 35 C to 110 C, prepared for the installation of a remote sensor, retrofitting can be done at any time on site. Standard version: Due date , battery warning off / opening detection in plain text / no summer switch-off - yet prepared, urther parameter setting options are possible on request or can be activated directly on site / can be changed using software Q suite Please note the instructions concerning approval of mixed operation. Please contact us if you have any questions. Communication: Q basic (no interface) Metering technology compatible with Q caloric 5, 201S and 202S/K, mixed operation is permitted! 1-sensor measuring principle K = 26, DD = C 1 HCA A1A ,00 2-sensor measuring principle K = 60, DD = C 1 HCA B3C ,55 Communication: Q opto (IrDA-interface) Metering technology compatible with Q caloric 5, 201S and 202S/K, mixed operation is permitted! 1-sensor measuring principle K = 26, DD = E 1 HCA A1A ,20 2-sensor measuring principle K = 60, DD = E 1 HCA B3C ,75 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 4

7 1 Heat cost allocators 1.1 Q caloric 5.5 (P2 + AL2) Communication: Radio / S-mode und - S-Mode features see page 1 - switch from S to C mode possible - re-parameterisation from 2-sensor to 1-sensor device possible Radio transmission compatible with Q caloric 5, mixed operation possible! Radio technology NOT compatible with 202R, mixed operation NOT possible! 2-sensor measuring principle K = 60, DD = F 1 HCA B3C ,05 2-sensor measuring principle + IrDA K = 60, DD = F 1 HCA5-000N-B3C ,25 Further Q caloric parameterising variants available on request. See also matrix on page 8. Communication: Radio / C-mode und - C-Mode features see page 1 - switch from C to S mode possible - re-parameterisation from 2-sensor to 1-sensor device possible Radio transmission not compatible in C-Mode with Q caloric 5 for AMR installations, Mixed operations possible with walk-by operations (read-out requirements: Q log current ACT46)! 2-sensor measuring principle K = 60, DD = F 1 HCA B3C ,05 2-sensor measuring principle + IrDA K = 60, DD = F 1 HCA5-000T-B3C ,25 Further Q caloric parameterising variants available on request. See also matrix on page 8. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 5

8 1 Heat cost allocators 1.2 Q caloric 5.5 (P3 + AL2) The heat cost allocators listed below are for installation in new systems (no attachment parts available on the radiator), for standard exchange in systems with existing QUNDIS devices Q caloric 5, WHE2, WHE3 and WHE4 (attachment parts available on the radiator) and for conversion installation in systems with external brands e.g. evaporator (attachment parts partly available). New installation: suitable installation plate has to be ordered Conversion installation: suitable installation plate has to be ordered Standard exchange: installation plate available EN 834-conform one-sensor or two-sensor heat cost allocator, storing of annual values with checksum, electromechanical contact for detecting device opening (e.g. in the case of manipulation), programmable due date and seal already pre-mounted in the housing, for average temperatures ranges from 55 C or 35 C to 110 C, prepared for the installation of a remote sensor, retrofitting can be done at any time on site. Standard version: Due date , battery warning off / opening detection in plain text / no summer switch-off - yet prepared, urther parameter setting options are possible on request or can be activated directly on site / can be changed using software Q suite 5 Please note the instructions concerning approval of mixed operation. Please contact us if you have any questions. Communication: Q basic (no interface) Metering technology compatible with Q caloric 5, mixed operation is permitted! Metering technology NOT compatible with WHE3, mixed operation is NOT permitted! 1-sensor measuring principle K = 26, ST = C 1 HCA A1A ,00 2-sensor measuring principle K = 60, ST = C 1 HCA B3C ,55 Communication: Q opto (IrDA-interface) Metering technology compatible with Q caloric 5, mixed operation is permitted! Metering technology NOT compatible with WHE3, mixed operation is NOT permitted! 1-sensor measuring principle K = 26, ST = E 1 HCA A1A ,20 2-sensor measuring principle K = 60, ST = E 1 HCA B3C ,75 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 6

9 1 Heat cost allocators 1.2 Q caloric 5.5 (P3 + AL2) Communication: Radio / S-mode und - S-Mode features see page 1 - switch from S to C mode possible - re-parameterisation from 2-sensor to 1-sensor device possible Radio transmission compatible with Q caloric 5, mixed operation possible! Metering technology NOT compatible with WHE4, mixed operation NOT possible! 2-sensor measuring principle K = 60, ST = F 1 HCA B3C ,05 2-sensor measuring principle + IrDA K = 60, ST = F 1 HCA5-003N-B3C ,25 Further Q caloric parameterising variants available on request. See also matrix on page 8. Communication: Radio / C-mode und - C-Mode features see page 1 - switch from C to S mode possible - re-parameterisation from 2-sensor to 1-sensor device possible Radio transmission not compatible in C-Mode with Q caloric 5 for AMR installations, Mixed operations possible with walk-by operations (read-out requirements: Q log current ACT46)! Metering technology NOT compatible with WHE4, mixed operation is NOT permitted! 2-sensor measuring principle K = 60, ST = F 1 HCA B3C ,05 2-sensor measuring principle + IrDA K = 60, ST = F 1 HCA5-003T-B3C ,25 Further Q caloric parameterising variants available on request. See also matrix on page 8. Other products for NEW INSTALLATION - STANDARD REPLACEMENT - REPAIR - CONVERSION (P3) Further product variants for Q caloric 5.5 new installation or for systems with existing devices / attachment parts of the series Q caloric 5 (P3), WHE3 and WHE4 with AL3 or AL4 can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 7

10 1 Heat cost allocators 1.3 Q caloric part number matrix Product family Block1 Block2 Block3 Block4 Basic Price Heat Cost Allocator Q caloric 5.5 HCA5 x x x x x x x x x x x x x 22,00 Logo Block1 Block2 Block3 Block4 Extra charge QUNDIS (standard) HCA5 0 0 x x x x x x x x x x x - Housing version Block1 Block2 Block3 Block4 Extra charge P2 (201/202 compatible) HCA5 x x 0 x x x x x x x x x x - P3 (WHE3 / WHE4 compatible) HCA5 x x 3 x x x x x x x x x x - Communication interface Block1 Block2 Block3 Block4 Extra charge none H C A 5 x x x 2 x x x x x x x x x - IrDA H C A 5 x x x 5 x x x x x x x x x 6,20 walk-by + AMR (S-mode) H C A 5 x x x 6 x x x x x x x x x 30,50 walk-by + AMR (C-mode) H C A 5 x x x 8 x x x x x x x x x 30,50 IrDA + walk-by + AMR (S-mode) H C A 5 x x x N x x x x x x x x x 36,70 IrDA + walk-by + AMR (C-mode) H C A 5 x x x T x x x x x x x x x 36,70 Measuring / calculation algorithm + Metering system Block1 Block2 Block3 Block4 Extra charge AL2-1-sensor - prepared for summer switch-off (only basic + IrDA) H C A 5 x x x x A x x x x x x x x - AL2-2-sensor - prepared for summer switch-off HCA5 xxxx B xxx xxxxx 1,55 AL3-2-sensor - prepared for summer switch-off HCA5 xxxx C xxx xxxxx 1,55 AL4-2-sensor - prepared for summer switch-off HCA5 xxxx D xxx xxxxx 1,55 AL3/4-1-sensor - prepared for summer switch-off (only basic + IrDA) H C A 5 x x x x E x x x x x x x x - K-level Block1 Block2 Block3 Block4 Extra charge none H C A 5 x x x x x 0 0 x x x x x x - 26 (standard for 1-sensor) H C A 5 x x x x x 1Ax x x x x x - 60 (standard for 2-sensor) H C A 5 x x x x x 3Cx x x x x x H C A 5 x x x x x X3x x x x x x - Approval Block1 Block2 Block3 Block4 Extra charge EN 834 H C A 5 x x x x x x x 0 x x x x x - France H C A 5 x x x x x x x 1 x x x x x - Denmark H C A 5 x x x x x x x 2 x x x x x - Russia H C A 5 x x x x x x x 3 x x x x x - Due date Block1 Block2 Block3 Block4 Extra charge standard H C A 5 x x x x x x x x 0 x x x x - more on request Special options Block1 Block2 Block3 Block4 Extra charge none (standard) H C A 5 x x x x x x x x x 0 x x x - Summer month beginning Block1 Block2 Block3 Block4 Extra charge none H C A 5 x x x x x x x x x x 0 x x - more on request Summer month end Block1 Block2 Block3 Block4 Extra charge none H C A 5 x x x x x x x x x x x 0 x - more on request Special options Block1 Block2 Block3 Block4 Extra charge none H C A 5 x x x x x x x x x x x x 0 - more on request Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 1, page 8

11 2 Compact heat meters Heat meters are devices which are mounted in a water cycle, can measure its heat output and save the data recorded. A distinction is made between heat meters and combined heat/cold meters. Heat meters record temperatures in the water circuit s supply and return flow as well as the volume flow rate, and assume a pure heat output of the pipe system (heating operation) for the consumption calculation. In contrast, combined heat/cold meters record both the heat output and the heat input of the pipe system (cooling operation). The data of both operating modes are managed in separate memoriesboth device types can display and/or store different values, e.g. the cumulated values at a selectable due date or end-of-the-month values and a fault message in case of an error. Meters without integrated communication can be retrofitted with communication add-on modules an integrated into the Q AMR, Q walk-by or Q M-Bus system. Module variants can be found from chapter 6 onwards. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 9

12 2 Compact heat meters 2.1 Q heat 5 - Screw-type meters (QDS) The heat meters listed below have been designed for installation in systems where an installation section is available with the dimensions listed next to the meter, and the meter is screwed to the pipework system by means of two union nuts. All suitable meters are marked with "QDS". MID-conform compact heat meter with integrated IrDA interface, inductive scanning process, current value as well as annual value and monthly values with checksum, detection of direction of rotation, programmable due date as well as display and storage of the maximum values, prepared for installation of external communication modules for integration in a Q walk-by, Q AMR or Q M-Bus system (see chapter 6 onwards), retrofitting on site is possible at any time, Parameter setting via the operating keys or the software Q suite 5 - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Q opto (IrDA-interface) Nominal flow 0.6 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 3/4" x 110 mm 5H 1 HMC ,00 Calculator unit removable G 3/4" x 110 mm 5I 1 HMR ,00 Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 3/4" x 110 mm 5H 1 HMC ,00 Calculator unit removable G 3/4" x 110 mm 5I 1 HMR ,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mmfor direct or immersion sleeve measurement Calculator unit cannot be removed G 1" x 130 mm 5H 1 HMC ,00 Calculator unit removable G 1" x 130 mm 5I 1 HMR ,00 Nominal flow 0.6 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 3/4" x 110 mm 5H 1 HMC ,00 Calculator unit removable G 3/4" x 110 mm 5I 1 HMR ,00 Nominal flow 1.5 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 3/4" x 110 mm 5H 1 HMC ,00 Calculator unit removable G 3/4" x 110 mm 5I 1 HMR ,00 Nominal flow 2.5 m³/h, temperature sensor 5.2 x 45 mmfor direct or immersion sleeve measurement Calculator unit cannot be removed G 1" x 130 mm 5H 1 HMC ,00 Calculator unit removable G 1" x 130 mm 5I 1 HMR ,00 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 18. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 10

13 2 Compact heat meters 2.2 Q heat 5 - Screw-type meters (QDS) incl. Q module 5.5 MID-conform compact heat meter - With mounted, sealed and parameterised radio add-on module - For integration into the Q AMR or Q walk-by system - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years Please note! Excluded from calibration (formerly re-calibration) and buyback. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Radio / S-mode und - S-Mode features see page 1 - Radio transmission compatible with heat meters incl.wfz166.ox / WFZ16.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5I 1 HMR5-000N A 335,00 Nominal flow 1.5 m³/h, temperature sensor 5.2 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5I 1 HMR5-000N A 335,00 Communication: Radio / C-mode und - C-Mode features see page 1 - Radio transmission (walk-by) compatible with WFZ166.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5I 1 HMR5-000T A 335,00 Nominal flow 1.5 m³/h, temperature sensor 5.2 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5I 1 HMR5-000T A 335,00 Note: Article numbers cover English language version and 10-year battery. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 11

14 2 Compact heat meters 2.3 Q heat 5 - Screw-type meters (QDS) - integrated communication The heat meters listed below have been designed for installation in systems where an installation section is available with the dimensions listed next to the meter, and the meter is screwed to the pipework system by means of two union nuts. MID-conform compact heat meter with integrated M-Bus and Impulse-IN interface inductive scanning process, display of current and cumulative values, check number and many service and operating parameters, storage of the maximum values, two additional impulse inputs for the connection of up to two water meters with impulse output, Parameter setting via the operating keys or the software Q suite 5 - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Q M-Bus / Impuls-IN Nominal flow 0.6 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5S 1 HMR5-000D ,00 Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5S 1 HMR5-000D ,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mmfor direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5S 1 HMR5-000D ,00 Note: Article numbers cover English language version and 10-year battery. Note: It is not possible to fit heat meters featuring integrated communication interfaces with external communication modules. Further Q heat parameterising variants available on request. See also matrix on page 18. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 12

15 2 Compact heat meters 2.3 Q heat 5 - Screw-type meters (QDS) - integrated communication The heat meters listed below have been designed for installation in systems where an installation section is available with the dimensions listed next to the meter, and the meter is screwed to the pipework system by means of two union nuts. MID-conform compact heat meter with integrated M-Bus inductive scanning process, display of current and cumulative values, check number and many service and operating parameters, storage of the maximum values, Parameter setting via the operating keys or the software Q suite 5 - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Q M-Bus Nominal flow 0.6 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5S 1 HMR5-000C ,00 Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5S 1 HMR5-000C ,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mmfor direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5S 1 HMR5-000C ,00 Note: Article numbers cover English language version and 10-year battery. Note: It is not possible to fit heat meters featuring integrated communication interfaces with external communication modules. Further Q heat parameterising variants available on request. See also matrix on page 18. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 13

16 2 Compact heat meters 2.4 Q heat 5 - Measuring capsule ISTA-compatible (IST) The heat meters listed below have been designed for installation in systems where an installation section is available with a ISTAcompatible single-pipe connection piece (EAT, EAS). All suitable meters are marked with "IST". MID-conform compact heat meter with integrated IrDA interface, inductive scanning process, current value as well as annual value and monthly values with checksum, detection of direction of rotation, programmable due date as well as display and storage of the maximum values, prepared for installation of external communication modules for integration in a Q walk-by, Q AMR or Q M-Bus system (see chapter 6 onwards), retrofitting on site is possible at any time, Parameter setting via the operating keys or the software Q suite 5 - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication Q opto (IrDA interface) Nominal flow 0.6 m³/h, Temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Nominal flow 1.5 m³/h, Temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Nominal flow 2.5 m³/h, Temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Nominal flow 0.6 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Nominal flow 1.5 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Nominal flow 2.5 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit cannot be removed G 2" 5J 1 HMC ,00 Calculator unit removable G 2" 5L 1 HMR ,00 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 18. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 14

17 2 Compact heat meters 2.5 Q heat 5 - Measuring capsule ISTA-compatible (IST) incl. Q module 5.5 MID-conform measuring capsule heat meter ISTA-compatible (IST) - With mounted, sealed and parameterised radio add-on module - For integration into the Q AMR or Q walk-by system - Measuring cycle: 36 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years Please note! Excluded from calibration (formerly re-calibration) and buyback. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Radio / S-mode und - S-Mode features see page 1 - Radio transmission compatible with heat meters incl.wfz166.ox / WFZ16.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 2" 5L 1 HMR5-000N A 345,00 Communication: Radio / C-mode und - C-Mode features see page 1 - Radio transmission (walk-by) compatible with WFZ166.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 2" 5L 1 HMR5-000T A 345,00 Note: Article numbers cover English language version and 10-year battery. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 15

18 2 Compact heat meters 2.6 Q heat 5 - Screw-type meters - Ultrasonic (US) Ultrasonic heat meters are used wherever especially precise measurements with long-term stability are required. The patented and innovative measuring process guarantees measuring accuracy over the whole product service life. The extremely small installation height allows it to be used in very narrow space. There is a free choice of installation position for the metering device, and even upside down installation is possible, allowing flexible adaptation to the installation conditions found on site. The device has a detachable calculator unit as a standard feature. All suitable Ultrasonic meters are marked with"us". MID-conform compact Ultrasonic heat meter with integrated IrDA interface, current value as well as annual value and monthly values with checksum, detection of direction of rotation, programmable due date as well as display and storage of the maximum values, prepared for installation of external communication modules for integration in a Q walk-by, Q AMR or Q M-Bus system (see chapter 6 onwards), retrofitting on site is possible at any time, Parameter setting via the operating keys or the software Q suite 5 - Measuring cycle: 12 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication Q opto (IrDA interface) Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5M 1 HMR5-00A ,00 Nominal flow 1.5 m³/h, temperature sensor 5.2 x 45 mm for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5M 1 HMR5-00A ,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mmfor direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5M 1 HMR5-00A ,00 Nominal flow 2.5 m³/h, temperature sensor 5.2 x 45 mmfor direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5M 1 HMR5-00A ,00 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 18. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 16

19 2 Compact heat meters 2.7 Q heat 5 - Screw-type meters - Ultrasonic (US) incl. Q module 5.5 MID-conform compact Ultrasonic heat meter - With mounted, sealed and parameterised radio add-on module - For integration into the Q AMR or Q walk-by system - Measuring cycle: 12 seconds - Display unit: kwh - Installation: Return flow - Battery: 10 years Please note! Excluded from calibration (formerly re-calibration) and buyback. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Communication: Radio / S-mode und - S-Mode features see page 1 - Radio transmission compatible with heat meters incl. WFZ166.Ox or WFZ16.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5M 1 HMR5-00AN A 355,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5M 1 HMR5-00AN A 365,00 Communication: Radio / C-mode walk-by und AMR - C-Mode features see page 1 - Radio transmission (walk-by) compatible with WFZ166.Ox, mixed operation possible! Nominal flow 1.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 3/4" x 110 mm 5M 1 HMR5-00AT A 355,00 Nominal flow 2.5 m³/h, temperature sensor 5.0 x 45 mm, 1.5 m sensor cable, for direct or immersion sleeve measurement Calculator unit removable G 1" x 130 mm 5M 1 HMR5-00AT A 365,00 Note: Article numbers cover English language version and 10-year battery. Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 17

20 2 Compact heat meters 2.8 Q heat 5 - part number matrix Product family Block1 Block2 Block3 Block4 Basic Price Heat Meter Compact Q heat 5 HMC5 x x x x x x x x x x x x x 230,00 Heat Meter Removable Q heat 5 HMR5 x x x x x x x x x x x x x 260,00 Logo Block1 Block2 Block3 Block4 Extra charge QUNDIS (standard) HMx x x x x x x x x x x x - Version Block1 Block2 Block3 Block4 Extra charge standard H M x 5 x x 0 x x x x x x x x x x - + cold metering (not MID-compliant) H M x 5 x x 1 x x x x x x x x x x 35,00 + solar metering (not MID-compliant) H M x 5 x x 2 x x x x x x x x x x 75,00 + cold metering + solar metering (not MID-compliant) H M x 5 x x 3 x x x x x x x x x x 110,00 + ultrasonic (only removable) HMR5 xxa x xxxx xxxxx 20,00 Communication interface Block1 Block2 Block3 Block4 Extra charge opto (IrDA) H M x 5 x x x 1 x x x x x x x x x - IrDA + M-Bus + Impuls in (1 liters per pulse / filter off) H M x 5 x x x 5 x x x x x x x x x 30,00 IrDA + M-Bus H M x 5 x x x C x x x x x x x x x 20,00 IrDA + M-Bus + Impuls in (10 liters per pulse / filter off) H M x 5 x x x D x x x x x x x x x 30,00 IrDA + walk-by + AMR (S-mode; add-on module with 10 year battery) H M x 5 x x x N x x x x x x x x A 70,00 IrDA + walk-by + AMR (C-mode; add-on module with 10 year battery) H M x 5 x x x T x x x x x x x x A 70,00 Flow sensor Block1 Block2 Block3 Block4 Extra charge Screwed connection m³/h mm - return flow installation H M x 5 x x x x 0 x x x x x x x x - Screwed connection m³/h mm - return flow installation H M x 5 x x x x 1 x x x x x x x x - Screwed connection m³/h mm - return flow installation H M x 5 x x x x 2 x x x x x x x x 10,00 Capsule (IST) m³/h - G2 - return flow installation H M x 5 x x x x 4 x x x x x x x x 10,00 Capsule (IST) m³/h - G2 - return flow installation H M x 5 x x x x 5 x x x x x x x x 10,00 Capsule (IST) m³/h - G2 - return flow installation H M x 5 x x x x 6 x x x x x x x x 20,00 Capsule (AMS) m³/h - M77x1,5 - return flow installation (only removable) H M R 5 x x x x 8 x x x x x x x x 15,00 Screwed connection m³/h - 80 mm - return flow installation H M x 5 x x x x H x x x x x x x x - Screwed connection m³/h mm - supply flow installation H M x 5 x x x x J x x x x x x x x 45,00 Screwed connection m³/h mm - supply flow installation H M x 5 x x x x K x x x x x x x x 45,00 Screwed connection m³/h mm - supply flow installation H M x 5 x x x x L x x x x x x x x 55,00 Capsule (IST) m³/h - G2 - supply flow installation H M x 5 x x x x M x x x x x x x x 55,00 Capsule (IST) m³/h - G2 - supply flow installation H M x 5 x x x x N x x x x x x x x 55,00 Capsule (IST) m³/h - G2 - supply flow installation H M x 5 x x x x O x x x x x x x x 65,00 Capsule (AMS) m³/h - M77x1,5 - supply flow installation (only removable) H M R 5 x x x x Q x x x x x x x x 70,00 Screwed connection m³/h - 80 mm - supply flow installation H M x 5 x x x x Y x x x x x x x x 45,00 Temperature sensor Block1 Block2 Block3 Block4 Extra charge 5,0 x 45 mm m H M x 5 x x x x x 0 x x x x x x x - 5,2 x 45 mm m H M x 5 x x x x x 1 x x x x x x x - 6,0 x 50 mm m H M x 5 x x x x x 2 x x x x x x x 15,00 nach AGFW m H M x 5 x x x x x 3 x x x x x x x 15,00 5,0 x 45 mm m H M x 5 x x x x x 4 x x x x x x x 15,00 5,2 x 45 mm m H M x 5 x x x x x 5 x x x x x x x 15,00 6,0 x 50 mm m H M x 5 x x x x x 6 x x x x x x x 30,00 nach AGFW m H M x 5 x x x x x 7 x x x x x x x 30,00 6,0 x 60 mm m (only AMS capsule) H M R 5 x x x x x 8 x x x x x x x - 6,0 x 60 mm m (only AMS capsule) H M R 5 x x x x x 9 x x x x x x x 15,00 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 18

21 2 Compact heat meters 2.8 Q heat 5 - part number matrix Power supply + measuring cycle Block1 Block2 Block3 Block4 Extra charge Battery 6 years - 36 seconds H M x 5 x x x x x x 0 x x x x x x - Battery 10 years - 36 seconds H M x 5 x x x x x x 1 x x x x x x 5,00 Battery 6 years - 6 seconds H M x 5 x x x x x x 4 x x x x x x 5,00 Battery 10 years - 12 seconds (only ultrasonic) H M x 5 x x x x x x 8 x x x x x x 5,00 Battery 6 years - 4 seconds (only ultrasonic) H M x 5 x x x x x x 9 x x x x x x - Approval + medium Block1 Block2 Block3 Block4 Extra charge Heat MID/Class 3, wihtou cold, water H M x 5 x x x x x x x 0 x x x x x - without - (heating) water + Glythermin P44 H M x 5 x x x x x x x A x x x x x - without - (heating) water + Tyfocor L H M x 5 x x x x x x x B x x x x x - without - (heating) water + Tyfocor N H M x 5 x x x x x x x C x x x x x - without - (heating) water + Antifrogen L H M x 5 x x x x x x x D x x x x x - without - (heating) water + Antifrogen N H M x 5 x x x x x x x E x x x x x - without - (heating) water + Dowcal 20 H M x 5 x x x x x x x F x x x x x - without - (heating) water + Gelbin DC 924 L H M x 5 x x x x x x x G x x x x x - without - (heating) water + Tyfocor LS H M x 5 x x x x x x x H x x x x x - without - (heating) water + Solarliquid L H M x 5 x x x x x x x L x x x x x - Due date Block1 Block2 Block3 Block4 Extra charge standard H M x 5 x x x x x x x x 0 x x x x - more on request Temperature switch-on threshold: Block1 Block2 Block3 Block4 Extra charge 1,0 / 0,2 K (standard) H M x 5 x x x x x x x x x 0 x x x - more on request Labeling and documenation Block1 Block2 Block3 Block4 Extra charge German (standard) H M x 5 x x x x x x x x x x 0 x x - English H M x 5 x x x x x x x x x x 2 x x - Italian H M x 5 x x x x x x x x x x 3 x x - French H M x 5 x x x x x x x x x x 4 x x - Spanish H M x 5 x x x x x x x x x x 5 x x - Greek H M x 5 x x x x x x x x x x 6 x x - Lithuanian H M x 5 x x x x x x x x x x 7 x x - Czech H M x 5 x x x x x x x x x x 8 x x - Polish H M x 5 x x x x x x x x x x 9 x x - Slovenian HMx5 xxxx xxxx xxax x - Russian HMx5 xxxx xxxx xxrx x - Turkish HMx5 xxxx xxxx xxtx x - Display Block1 Block2 Block3 Block4 Extra charge kwh (Standard) H M x 5 x x x x x x x x x x x 0 x - GJ H M x 5 x x x x x x x x x x x 4 x - more on request Special options Block1 Block2 Block3 Block4 Extra charge none H M x 5 x x x x x x x x x x x x 0 - Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 2, page 19

22 3 Split heat meters Heat meters are devices which are mounted in a water cycle, can measure its heat output and save the data recorded. A distinction is made between heat meters and combined heat/cold meters. Heat meters record temperatures in the water circuit s supply and return flow as well as the volume flow rate, and assume a pure heat output of the pipe system (heating operation) for the consumption calculation. In contrast, combined heat/cold meters record both the heat output and the heat input of the pipe system (cooling operation). The data of both operating modes are managed in separate memories. Both device types can display and/or store different values, e.g. the cumulated values at a selectable due date or end-of-the-month values and a fault message in case of an error. Both device types are optionally available with an integrated M-Bus module. In addition, all the meters featured in this chapter can be retrofitted with external communication modules on site and can thus be integrated in the Q AMR, Q walk-by or Q M-Bus system. You can find the external module variants from chapter 6 onwards. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 21

23 3 Split heat meters The heat meters listed below have been designed for installation in systems where there is an installation section available with the dimensions listed next to the meter. 3.1 Ultrasonic flow sensors (thread) MID-compliant split heat meter G 03 consisting of: calculator unit with optical interface for programming / readout and for retrofitting of external communication modules, MID-compliant pair of temperature sensors PT for dimensions see below with 3 m cable, direct measurement up to nominal flow of 6.0 m³/h, ultrasonic flow sensor with thread connections and a dynamic ratio of 1:100 for any required installation position, up to and including a nominal flow of 10.0 m³/h with 5.6 mm sensor bore hole, operating pressure PN16 bar, approved medium temperature 130 C up to Qp 2.5 and 150 C from Qp 3.5, display of annual value with check number, programmable scheduled date, parameterisation possible via operating key and adapter ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. G 03 nominal flow rate 0.6 m³/h, temperature sensor 5.2 x 45 mm Standard G 3/4" x 110 mm C5 1 G M ,20 alternative flow sensor G 1" x 130 mm C5 1 G M 4003 with H 4 369,50 alternative flow sensor G 1" x 190 mm C5 1 G M 4003 with H 4 378,30 G 03 nominal flow rate 1.5 m³/h, temperature sensor 5.2 x 45 mm Standard G 3/4" x 110 mm C5 1 G M ,20 alternative flow sensor G 1" x 130 mm C5 1 G M 4003 with H 4 378,30 alternative flow sensor G 1" x 190 mm C5 1 G M 4003 with H 4 384,80 G 03 nominal flow rate 2.5 m³/h, temperature sensor 5.2 x 45 mm Standard G 1" x 130 mm C5 1 G M ,00 alternative flow sensor G 1" x 190 mm C5 1 G M 4003 with H 4 422,80 G 03 nominal flow rate 3.5 m³/h, temperature sensor 6.0 x 105 mm (for existing installations) Standard G 5/4" x 260 mm C5 1 G M ,67 alternative G 5/4" x 135 mm C5 1 G M 4003 with H 4 652,17 alternative G 5/4" x 150 mm C5 1 G M 4003 with H 4 652,17 alternative G 1½" x 150 mm C5 1 G M 4003 with H 4 652,17 alternative G 1½" x 260 mm C5 1 G M 4003 with H 4 591,67 G 03 nominal flow rate 3.5 m³/h, temperature sensor 5.2 x 45 mm (for new installations) Standard G 5/4" x 260 mm C5 1 G M ,40 alternative flow sensor G 5/4" x 135 mm C5 1 G M 4003 with H 4 595,90 alternative flow sensor G 5/4" x 150 mm C5 1 G M 4003 with H 4 595,90 alternative flow sensor G 1½" x 150 mm C5 1 G M 4003 with H 4 595,90 alternative flow sensor G 1½" x 260 mm C5 1 G M 4003 with H 4 535,40 G 03 nominal flow rate 6.0 m³/h, temperature sensor 6.0 x 105 (for existing installations) Standard G 5/4" x 260 mm C5 1 G M ,67 alternative flow sensor G 5/4" x 135 mm C5 1 G M 4003 with H 4 652,17 alternative flow sensor G 5/4" x 150 mm C5 1 G M 4003 with H 4 652,17 alternative flow sensor G 1½" x 150 mm C5 1 G M 4003 with H 4 697,17 alternative flow sensor G 1½" x 260 mm C5 1 G M 4003 with H 4 697,17 alternative flow sensor G 2" x 150 mm C5 1 G M 4003 with H 4 736,22 G 03 nominal flow rate 6.0 m³/h, temperature sensor 5.2 x 45 mm (for new installations) Standard G 5/4" x 260 mm C5 1 G M ,40 alternative flow sensor G 5/4" x 135 mm C5 1 G M 4003 with H 4 595,90 alternative flow sensor G 5/4" x 150 mm C5 1 G M 4003 with H 4 595,90 alternative flow sensor G 1½" x 150 mm C5 1 G M 4003 with H 4 640,90 alternative flow sensor G 1½" x 260 mm C5 1 G M 4003 with H 4 640,90 alternative flow sensor G 2" x 150 mm C5 1 G M 4003 with H 4 679,95 G 03 nominal flow rate 10.0 m³/h, temperature sensor 6.0 x 105 mm Standard G 2" x 300 mm C5 1 G M ,20 alternative flow sensor G 2" x 200 mm C5 1 G M 4003 with H 4 795,47 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 25. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 22

24 3 Split heat meters 3.2 Ultrasonic flow sensors (flange) MID-compliant split heat meter G 04 consisting of: calculator unit with optical interface for programming / readout and for retrofitting of external communication modules, MID-compliant pair of temperature sensors PT for dimensions see below with 3 m cable, direct measurement up to nominal flow of 6.0 m³/h, ultrasonic flow sensor with flange connections and a dynamic ratio of 1:100 for any required installation position, up to and including a nominal flow of 10.0 m³/h with 5.6 mm sensor bore hole, operating pressure PN25 bar, approved medium temperature 150 C, display of annual value with check number, programmable scheduled date, parameterisation possible via operating key and adapter ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. G 04 nominal flow rate 3.5 m³/h, temperature sensor 6.0 x 105 (for existing installations) DN 25 x 260 mm C5 1 G M ,07 G 04 nominal flow rate 3.5 m³/h, temperature sensor 5.2 x 45 mm (for new installations) DN 25 x 260 mm C5 1 G M ,80 G 04 nominal flow rate 6.0 m³/h, temperature sensor 6.0 x 105 mm (for existing installations) DN 25 x 260 mm C5 1 G M ,07 alternative flow sensor DN 32 x 260 mm C5 1 G M 4003 with H 4 774,27 G 04 nominal flow rate 6.0 m³/h, temperature sensor 5.2 x 45 mm (for new installations) DN 25 x 260 mm C5 1 G M ,80 alternative flow sensor DN 32 x 260 mm C5 1 G M 4003 with H 4 718,00 G 04 nominal flow rate 10.0 m³/h, temperature sensor 6.0 x 105 mm DN 40 x 300 mm C5 1 G M ,50 G 04 nominal flow rate 15.0 m³/h, temperature sensor 6.0 x 140 mm DN 50 x 270 mm C5 1 G M ,80 G 04 nominal flow rate 25.0 m³/h, temperature sensor 6.0 x 140 mm DN 65 x 300 mm C5 1 G M ,90 G 04 nominal flow rate 40.0 m³/h, temperature sensor 6.0 x 140 mm DN 80 x 300 mm C5 1 G M ,70 G 04 nominal flow rate 60.0 m³/h, temperature sensor 6.0 x 140 mm DN 100 x 360 mm C5 1 G M 4003 with H ,97 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 25. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 23

25 3 Split heat meters 3.3 Woltmann flow sensors (flange) MID-compliant split heat meter G 04 consisting of: calculator unit with optical interface for programming / readout and for retrofitting of external communication modules, Woltman flow sensor with flange connections for the indicated installation position, display of annual value with check number, programmable scheduled date, approved medium temperature 120 C, parameterisation possible via operating key and adapter - mounting: return flow - battery life: 10 years - MID-compliant pair of temperature sensors: PT 1000 with 6.0 x 140 mm and 3 m cable ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. G 04 nominal flow rate 15.0 m³/h for horizontal installation 4-hole DN 50 x 270 mm C5 1 G M ,10 G 04 nominal flow rate 25.0 m³/h for horizontal installation 4-hole DN 65 x 300 mm C5 1 G M ,30 G 04 nominal flow rate 40.0 m³/h for horizontal installation 8-hole DN 80 x 300 mm C5 1 G M ,30 G 04 nominal flow rate 60.0 m³/h for horizontal installation 8-hole DN 100 x 360 mm C5 1 G M ,00 G 04 nominal flow rate 15.0 m³/h for horizontal / vertical installation 4-hole DN 50 x 200 mm C5 1 G M ,10 G 04 nominal flow rate 25.0 m³/h for horizontal / vertical installation 4-hole DN 65 x 200 mm C5 1 G M ,30 G 04 nominal flow rate 32.0 m³/h for horizontal / vertical installation 8-hole DN 80 x 225 mm C5 1 G M ,30 G 04 nominal flow rate 60.0 m³/h for horizontal / vertical installation 8-hole DN 100 x 250 mm C5 1 G M ,00 G 04 nominal flow rate m³/h for horizontal / vertical installation 8-hole DN 125 x 250 mm C5 1 G M ,50 G 04 nominal flow rate m³/h for horizontal / vertical installation 8-hole DN 150 x 300 mm C5 1 G M ,40 G 04 nominal flow rate m³/h for horizontal / vertical installation 12-hole DN 200 x 350 mm C5 1 G M ,40 Note: Article numbers cover English language version and 10-year battery. Further Q heat parameterising variants available on request. See also matrix on page 25. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 24

26 3 Split heat meters 3.4 Q heat split - part number matrix Product family + version AAA BBBB CC D EFGH Price Device Heat meter with threaded connections G03 x x x x x x x x x x x 126,50 Heat meter with flange connections G04 x x x x x x x x x x x 126,50 Combined heat/cold meter with threaded connections G13 x x x x x x x x x x x 162,10 Combined heat/cold meter with flange connections G14 x x x x x x x x x x x 162,10 Solar heat meter with threaded connections G18 x x x x x x x x x x x 227,10 Solar heat meter with flange connections G19 x x x x x x x x x x x 227,10 ASN code flow sensor Price flow sensor Ultrasonic flow sensors - thread AAA BBBB CC D EFGH Ultrasonic / any installation position / qp 0.6 m³/h - G ¾" x 110 mm Gxx x x x x x x x H 4 148,00 Ultrasonic / any installation position / qp 0.6 m³/h - G 1" x 130 mm Gxx x x x x x x x H 4 153,30 Ultrasonic / any installation position / qp 0.6 m³/h - G 1" x 190 mm Gxx x x x x x x x H 4 162,10 Ultrasonic / any installation position / qp 1.5 m³/h - G ¾" x 110 mm Gxx x x x x x x x H 4 148,00 Ultrasonic / any installation position / qp 1.5 m³/h - G ¾" x 130 mm Gxx x x x x x x x H 4 162,10 Ultrasonic / any installation position / qp 1.5 m³/h - G1" x 190 mm Gxx x x x x x x x H 4 168,60 Ultrasonic / any installation position / qp 2.5 m³/h - G 1" x 130 mm Gxx x x x x x x x H 4 156,80 Ultrasonic / any installation position / qp 2.5 m³/h - G 1" x 190 mm Gxx x x x x x x x H 4 206,60 Ultrasonic / any installation position / qp 3.5 m³/h - G 1¼" x 260 mm Gxx x x x x x x x H 4 319,20 Ultrasonic / any installation position / qp 3.5 m³/h - G 1¼" x 135 mm Gxx x x x x x x x H 4 379,70 Ultrasonic / any installation position / qp 3.5 m³/h - G 1¼" x 150 mm Gxx x x x x x x x H 4 379,70 Ultrasonic / any installation position / qp 3.5 m³/h - G 1½" x 150 mm Gxx x x x x x x x H 4 379,70 Ultrasonic / any installation position / qp 3.5 m³/h - G 1½" x 260 mm Gxx x x x x x x x H 4 319,20 Ultrasonic / any installation position / qp 6.0 m³/h - G 1¼" x 260 mm Gxx x x x x x x x H 4 319,20 Ultrasonic / any installation position / qp 6.0 m³/h - G 1¼" x 135 mm Gxx x x x x x x x H 4 379,70 Ultrasonic / any installation position / qp 6.0 m³/h - G 1¼ " x 150 mm Gxx x x x x x x x H 4 379,70 Ultrasonic / any installation position / qp 6.0 m³/h - G 1½" x 150 mm Gxx x x x x x x x H 4 424,70 Ultrasonic / any installation position / qp 6.0 m³/h - G 1½" x 260 mm Gxx x x x x x x x H 4 424,70 Ultrasonic / any installation position / qp 6.0 m³/h - G 2" x 150 mm Gxx x x x x x x x H 4 463,75 Ultrasonic / any installation position / qp 10.0 m³/h - G 2" x 300 mm Gxx x x x x x x x H 4 463,73 Ultrasonic / any installation position / qp 10.0 m³/h - G 2" x 200 mm Gxx x x x x x x x H 4 523,00 ASN code flow sensor Price flow sensor Ultrasonic flow sensors - flange AAA BBBB CC D EFGH Ultrasonic / any installation position / qp 3.5 m³/h - FL DN mm Gxx x x x x x x x H 4 476,60 Ultrasonic / any installation position / qp 6.0 m³/h - FL DN mm Gxx x x x x x x x H 4 476,60 Ultrasonic / any installation position / qp 6.0 m³/h - FL DN mm Gxx x x x x x x x H 4 501,80 Ultrasonic / any installation position / qp 10.0 m³/h - FL DN mm Gxx x x x x x x x H 4 628,00 Ultrasonic / any installation position / qp 15.0 m³/h - FL DN mm Gxx x x x x x x x H 4 974,20 Ultrasonic / any installation position / qp 25.0 m³/h - FL DN mm Gxx x x x x x x x H ,30 Ultrasonic / any installation position / qp 40.0 m³/h - FL DN mm Gxx x x x x x x x H ,13 Ultrasonic / any installation position / qp 40.0 m³/h - FL DN mm Gxx x x x x x x x H ,40 ASN code flow sensor Price flow sensor Woltman-jet flow sensors - flange AAA BBBB CC D EFGH Woltman-jet / horizontal / qp 15.0 m³/h - FL DN mm Gxx x x x x x x H 4 793,30 Woltman-jet / horizontal / qp 25.0 m³/h - FL DN mm Gxx x x x x x x H 4 825,50 Woltman-jet / horizontal / qp 40.0 m³/h - FL DN mm Gxx x x x x x x H 4 936,50 Woltman-jet / horizontal / qp 60.0 m³/h - FL DN mm Gxx x x x x x x H ,20 Woltman-jet / horizontal + vertical / qp 15.0 m³/h - FL DN mm Gxx x x x x x x H 4 793,30 Woltman-jet / horizontal + vertical / qp 25.0 m³/h - FL DN mm Gxx x x x x x x H 4 825,50 Woltman-jet / horizontal + vertical / qp 32.0 m³/h - FL DN mm Gxx x x x x x x H 4 936,50 Woltman-jet / horizontal + vertical / qp 60.0 m³/h - FL DN mm Gxx x x x x x x H ,20 Woltman-jet / horizontal + vertical / qp m³/h - FL DN mm Gxx x x x x x x H ,70 Woltman-jet / horizontal + vertical / qp m³/h - FL DN mm Gxx x x x x x x H ,60 Woltman-jet / horizontal + vertical / qp m³/h - FL DN mm Gxx x x x x x x H ,60 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 25

27 3 Split heat meters 3.4 Q heat split - part number matrix Logo AAA BBBB CC D EFGH Price QUNDIS G x x x x x x 0 x x x x x x - Temperature sensor AAA BBBB CC D EFGH Price 5.2 x 45 mm / 3.0 m cable G x x x x x x x 0 x x x x x 61, x 105 mm / 3.0 m cable G x x x x x x x 1 x x x x x 118, x 140 mm / 3.0 m cable G x x x x x x x 2 x x x x x 121, x 45 mm / 10.0 m cable G x x x x x x x 3 x x x x x 122, x 105 mm / 10.0 m cable G x x x x x x x 4 x x x x x 184, x 140 mm / 10.0 m cable G x x x x x x x 5 x x x x x 187,70 Initial calibration AAA BBBB CC D EFGH Price heat MID, cold without (standard) G x x x x x x x x M x x x x - heat without, cold without G x x x x x x x x E x x x x - Power supply AAA BBBB CC D EFGH Price 6-year battery G x x x x x x x x x 0 x x x - 10-year battery G x x x x x x x x x 1 x x x 5,00 6-year battery + 2nd battery (for Ultrasonic) G x x x x x x x x x 3 x x x 22,77 10-year battery + 2nd battery (for Ultrasonic) G x x x x x x x x x 4 x x x 27,77 Installation location for flow sensor AAA BBBB CC D EFGH Price Return flow (cold pipe) G x x x x x x x x x x 0 x x - Supply flow (hot pipe) G x x x x x x x x x x 1 x x 58,80 Internal communication module AAA BBBB CC D EFGH Price none G x x x x x x x x x x x 0 x - M-Bus G x x x x x x x x x x x 2 x 70,20 Impulse output G x x x x x x x x x x x 3 x 27,20 Impulse output combined heat/cold meter G x x x x x x x x x x x 3 x 37,50 Approval mark + marking language AAA BBBB CC D EFGH Price MID, German G x x x x x x x x x x x x 0 - MID, English G x x x x x x x x x x x x 3 - MID, Italian G x x x x x x x x x x x x 4 - MID, Spanish G x x x x x x x x x x x x 5 - MID, Lithuanian G x x x x x x x x x x x x 8 - Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 26

28 3 Split heat meters 3.5 Calculator units MID-conform calculator unit opt. interface for programming / readout as well as retrofitting of external communication modules, for the connection of the given temperature sensors either using 2 or 4-conductor technology as well as flow sensors with its specified pulse values, display of the annual value with checksum, programmable due date, display unit MWh, Parameter setting via the operating key and adapter possible Suitable for the connection of any required flow sensors with impulse output. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Calculator units R 20 with 10-year battery, display unit MWh without additional power supply via the calculator unit Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Heat meter PT l/imp. C4 1 R M ,70 Calculator units R 21 with 10-year battery, display unit MWh without additional power supply via the calculator unit Combined heat / cold meter PT l/imp. C4 1 R M ,30 Combined heat / cold meter PT l/imp. C4 1 R M ,30 Combined heat / cold meter PT l/imp. C4 1 R M ,30 Combined heat / cold meter PT l/imp. C4 1 R M ,30 Calculator units R 28 with 10-year battery, display unit MWh without additional power supply via the calculator unit Solar heat meter - Medium: Dowcal 20 PT l/imp. C4 1 R E ,70 Solar heat meter - Medium: Antifrogen N PT l/imp. C4 1 R E ,70 Solar heat meter - Medium: Tyfocor L PT l/imp. C4 1 R E ,70 Note: Article numbers cover English language version and 10-year battery. Other split calculator variants are available on request: - Adaptations for glycol additives - Volume measurement in the supply flow (hot pipe) - Combined heat and cold meters (cold metering not MID-compliant) - Integrated M-Bus module - For temperature sensor connection PT100 or PT500 - integrated impulse output module - Devices with 6-year battery - Display unit kwh, MJ, kj - Display of decimal places - Marking languages: German, English, Italien, Spanisch, Lithuanian Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 27

29 3 Split heat meters 3.5 Calculator units Calculator units R 20 with 10-year battery + 2nd battery, display unit MWh with additional power supply via the calculator unit (standard for QUNDIS split heat meters with ultrasonic flow sensors) Heat meter PT l/imp. C4 1 R20-F M ,50 Heat meter PT l/imp. C4 1 R20-F M ,50 Heat meter PT l/imp. C4 1 R20-F M ,50 Heat meter PT l/imp. C4 1 R20-F M ,50 Heat meter PT l/imp. C4 1 R20-F M ,50 Heat meter PT l/imp. C4 1 R20-F M ,50 Note: Article numbers cover English language version and 10-year battery. Other split calculator variants are available on request: - Adaptations for glycol additives - Volume measurement in the supply flow (hot pipe) - Combined heat and cold meters (cold metering not MID-compliant) - Integrated M-Bus module - For temperature sensor connection PT100 or PT500 - integrated impulse output module - Devices with 6-year battery - Display unit kwh, MJ, kj - Display of decimal places - Marking languages: German, English, Italien, Spanisch, Lithuanian Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 3, page 28

30 4 Water meters Water meters are mainly used in business to measure hot and cold water consumption. QUNDIS supplies water meters both as screw-type and capsule meter variants. Depending on the type of meter and installation material used, they can be mounted on-wall or in-wall directly in the water pipe. An impellor sensor measures the flow, with the cumulated consumption either shown by a counter on mechanical water meters or on a display in the case of electronic water meters. As a recognised State Testing Centre for water meters, we can calibrate water meters and check their functionality and precision. This also allows us to use this quality assurance tool for our own developments of course, and put new developments and devices through their paces under real conditions. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 29

31 4 Water meters 4.1 Q water Electronic screw-type water meters The new water meter generation from QUNDIS provides both screw-type and capsule meters. Thanks to a great selection of measuring capsule versions for the most common connection interfaces from all major manufacturers, nearly every installation situation can be handled. With the improved radio performance and flexibility during readout, the Q water 5.5 is setting new standards. Product details: - MID-compliant screw-type and measuring capsule water meter (precision classes R80 horizontal /R40 vertical) - Easy fitting thanks to a plastic capsule seal and automatic radio activation - No parameterising required - High device protection level (IP68) - IrDA-interface for readout and parameterisation of the water meter rotatable calculator unit with 8-digit LC display - Horizontal and vertical installation possible - Counts forwards and backwards - Leaks are reported - Electronic scanning makes tampering impossible - Saving of 13 monthly values Communication: Radio / S-mode und - S-mode features see page 1 - switch from S to C mode possible ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h - Connection thread G 3/4" (ISO 228) - Nominal width 15 (DN) Installation length 80 mm max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Installation length 110 mm max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Permanent flow rate Q₃ 4.0 m³/h - Connection thread G 1" (ISO 228) - Nominal width 20 (DN) Installation length 130 mm max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 30

32 4 Water meters 4.1 Q water Electronic screw-type water meters Product details: - MID-compliant screw-type and measuring capsule water meter (precision classes R80 horizontal /R40 vertical) - Easy fitting thanks to a plastic capsule seal and automatic radio activation - No parameterising required - High device protection level (IP68) - IrDA-interface for readout and parameterisation of the water meter rotatable calculator unit with 8-digit LC display - Horizontal and vertical installation possible - Counts forwards and backwards - Leaks are reported - Electronic scanning makes tampering impossible - Saving of 13 monthly values Communication: Radio / C-Mode und - C-mode features see page 1 - switch from C to S mode possible ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h - Connection thread G 3/4" (ISO 228) - Nominal width 15 (DN) Installation length 80 mm max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Installation length 110 mm max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Permanent flow rate Q₃ 4.0 m³/h - Connection thread G 1" (ISO 228) - Nominal width 20 (DN) Installation length 130 mm max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 31

33 4 Water meters 4.2 Q water 4 - Mechanical screw-type water meters incl. Q module 5.5 Communication: Radio / S-mode und Mechanical water meter on-wall (single-jet) - with mounted and parameterised radio add-on module - for integration into the Q AMR or Q walk-by system (S-Mode) - Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - Dry runner, impeller wheel - MID approval - S-Mode features see page 1 - switch from S to C mode possible Radio transmission compatible with water meters incl. WFZ166.MO and WFZ16.MO, mixed operation possible! Please note! Excluded from calibration (formerly re-calibration) and buyback. Supplied in batches of 20 pieces. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h - Connection thread G 3/4" (ISO 228) - Nominal width 15 (DN) Installation length 80 mm max. 30 C water temperature 5P 1 WMM5-000N ,00 max. 90 C water temperature 5P 1 WMM5-001N ,00 Installation length 110 mm max. 30 C water temperature 5P 1 WMM5-000N ,00 max. 90 C water temperature 5P 1 WMM5-001N ,00 Permanent flow rate Q₃ 4.0 m³/h - Connection thread G 1" (ISO 228) - Nominal width 20 (DN) Installation length 130 mm max. 30 C water temperature 5P 1 WMM5-000N ,00 max. 90 C water temperature 5P 1 WMM5-001N ,00 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 32

34 4 Water meters 4.2 Q wtaer 4 - Mechanical screw-type water meters incl. Q module 5.5 Communication: Radio / C-mode und Mechanical water meter on-wall (single-jet) - with mounted and parameterised radio add-on module - for integration into the Q AMR or Q walk-by system (C-Mode) - Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - Dry runner, impeller wheel - MID approval - C-Mode features see page 1 - switch from C to S mode possible Radio transmission compatible with walk-by installations with WFZ166.MO, mixed operations possible (read-out requirements: Q log current ACT46). Please note! Excluded from calibration (formerly re-calibration) and buyback. Supplied in batches of 20 pieces. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h - Connection thread G 3/4" (ISO 228) - Nominal width 15 (DN) Installation length 80 mm max. 30 C water temperature 5P 1 WMM5-000T ,00 max. 90 C water temperature 5P 1 WMM5-001T ,00 Installation length 110 mm max. 30 C water temperature 5P 1 WMM5-000T ,00 max. 90 C water temperature 5P 1 WMM5-001T ,00 Permanent flow rate Q₃ 4.0 m³/h - Connection thread G 1" (ISO 228) - Nominal width 20 (DN) Installation length 130 mm max. 30 C water temperature 5P 1 WMM5-000T ,00 max. 90 C water temperature 5P 1 WMM5-001T ,00 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 33

35 4 Water meters 4.3 Q water 4 - Mechanical screw-type water meters Communication: basic Mechanical water meter on-wall (single-jet) - Dry runner, impeller wheel - Module shaft for retrofitting external communication modules - MID approval ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h - Connection thread G 3/4" (ISO 228) - Nominal width 15 (DN) Installation length 80 mm Q water 4 (WEH) - max. 30 C water temperature MA 1 WFK30.D080 36,90 Q water 4 (WEH) - max. 90 C water temperature MA 1 WFW30.D080 36,90 Q water 4 (MAD) - max. 30 C water temperature MA 1 WMMH Z1V00 30,40 Q water 4 (MAD) - max. 90 C water temperature MA 1 WMMH Z1V00 30,40 Installation length 110 mm Q water 4 (WEH) - max. 30 C water temperature MA 1 WFK30.D110 36,90 Q water 4 (WEH) - max. 90 C water temperature MA 1 WFW30.D110 36,90 Q water 4 (MAD) - max. 30 C water temperature MA 1 WMMH Z1V00 30,40 Q water 4 (MAD) - max. 90 C water temperature MA 1 WMMH Z1V00 30,40 Permanent flow rate Q₃ 4.0 m³/h - Connection thread G 1" (ISO 228) - Nominal width 20 (DN) Installation length 130 mm Q water 4 (WEH) - max. 30 C water temperature MA 1 WFK30.E130 49,10 Q water 4 (WEH) - max. 90 C water temperature MA 1 WFW30.E130 49,10 Q water 4 (MAD) - max. 30 C water temperature MA 1 WMMH Z1V00 44,60 Q water 4 (MAD) - max. 90 C water temperature MA 1 WMMH Z1V00 44,60 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 34

36 4 Water meters 4.4 Q water Electronic measuring capsule water meters The new water meter generation from QUNDIS provides both screw-type and capsule meters. Thanks to a great selection of measuring capsule versions for the most common connection interfaces from all major manufacturers, nearly every installation situation can be handled. With the improved radio performance and the flexibility during readout, the Q water 5.5 is setting new standards. Product details: - MID-compliant screw-type and measuring capsule water meter (precision classes R80 horizontal /R40 vertical) - Easy fitting thanks to a plastic capsule seal and automatic radio activation - No parameterising required - High device protection level (IP68) - IrDA-interface for readout and parameterisation of the water meter rotatable calculator unit with 8-digit LC display - Horizontal and vertical installation possible - Counts forwards and backwards - Leaks are reported - Electronic scanning makes tampering impossible - Saving of 13 monthly values Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 35

37 4 Water meters 4.4 Q water Electronic measuring capsule water meters Communication: Radio / S-mode und - S-mode features see page 1 - switch from S to C mode possible ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Connection interface IST (Ista) - Connection thread G 2" - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Connection interface A34 (Allmess) - Connection thread M77 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Connection interface TE1 (Techem) - Connection thread M62 x 2 - Permanent flow rate Q₃ 2,5 m³/h max. 30 C water temperature MF 1 WME5-000N V00 95,20 max. 90 C water temperature MF 1 WME5-001N V00 95,20 Note: The Q water connection interface TE1 - is not compatible with the original thrust tubes and covers. Suitable hrust tubes and covers can be found in our digital accessories price list. Connection interface MOC/MOE (Elster/ABB) - Connection thread M65 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-A111 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-A111 00V00 95,20 Connection interface MET (Brunata/Metrona HT3) - Connection thread M64 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-C111 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-C111 00V00 95,20 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 36

38 4 Water meters 4.4 Q water Electronic measuring capsule water meters Communication: Radio / S-mode und Connection interface HT2 (Brunata HT2/Metrona 307) - Connection thread M66 x 1 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-E011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-E011 00V00 95,20 Connection interface MB3 (Minol) - Connection thread M76 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-J011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-J011 00V00 95,20 Connection interface DM1 (Deltamess TK) - Connection thread M60 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-T011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-T011 00V00 95,20 Connection interface MUK (Sensus PolluMUK) - Connection thread G2 1/4" - Permanent flow rate Q ₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-V011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-V011 00V00 95,20 Connection interface WE1 (Wehrle) - Connection thread M78 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-W011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-W011 00V00 95,20 Connection interface WGU (Wassergeräte) - Connection thread M66 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000N-X011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001N-X011 00V00 95,20 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 37

39 4 Water meters 4.4 Q water Electronic measuring capsule water meters Communication: Radio / C-mode und - C-mode features see page 1 - switch from C to S mode possible ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Connection interface IST (Ista) - Connection thread G 2" - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Connection interface A34 (Allmess) - Connection thread M77 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Connection interface TE1 (Techem) - Connection thread M62 x 2 - Permanent flow rate Q₃ 2,5 m³/h max. 30 C water temperature MF 1 WME5-000T V00 95,20 max. 90 C water temperature MF 1 WME5-001T V00 95,20 Note: The Q water connection interface TE1 - is not compatible with the original thrust tubes and covers. Suitable hrust tubes and covers can be found in our digital accessories price list. Connection interface MOC/MOE (Elster/ABB) - Connection thread M65 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-A111 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-A111 00V00 95,20 Connection interface MET (Brunata/Metrona HT3) - Connection thread M64 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-C111 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-C111 00V00 95,20 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 38

40 4 Water meters 4.4 Q water Electronic measuring capsule water meters Communication: Radio / C-mode und Connection interface HT2 (Brunata HT2/Metrona 307) - Connection thread M66 x 1 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-E011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-E011 00V00 95,20 Connection interface MB3 (Minol) - Connection thread M76 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-J011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-J011 00V00 95,20 Connection interface DM1 (Deltamess TK) - Connection thread M60 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-T011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-T011 00V00 95,20 Connection interface MUK (Sensus PolluMUK) - Connection thread G2 1/4" - Permanent flow rate Q ₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-V011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-V011 00V00 95,20 Connection interface WE1 (Wehrle) - Connection thread M78 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-W011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-W011 00V00 95,20 Connection interface WGU (Wassergeräte) - Connection thread M66 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MF 1 WME5-000T-X011 00V00 95,20 max. 90 C water temperature MF 1 WME5-001T-X011 00V00 95,20 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 39

41 4 Water meters 4.5 Q water 4 - Mechanical measuring capsule water meters incl. Q module 5.5 Communication: Radio / S-mode und Mechanical water meter measuring capsule - with mounted and parameterised radio add-on module - for integration into the Q walk-by System or Q AMR System (S-mode) - Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - Dry runner, impeller wheel - MID approval - S-Mode features see page 1 - switch from S to C mode possible Radio transmission compatible with water meters incl. WFZ166.MO and WFZ16.MO, mixed operation possible! Please note! Excluded from calibration (formerly re-calibration) and buyback. Supplied in batches of 20 pieces. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m³/h Connection interface IST (Ista) - Connection thread G 2" - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000N ,00 max. 90 C water temperature 5P 1 WMM5-001N ,00 Connection interface A34 (Allmess) - Connection thread M77 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000N ,00 max. 90 C water temperature 5P 1 WMM5-001N ,00 Connection interface MOC/MOE (Elster/ABB) - Connection thread M65 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000N-A ,00 max. 90 C water temperature 5P 1 WMM5-001N-A ,00 Connection interface MET (Brunata/Metrona HT3)- Connection thread M64 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000N-C ,00 max. 90 C water temperature 5P 1 WMM5-001N-C ,00 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 40

42 4 Water meters 4.5 Q water 4 - Mechanical measuring capsule water meters incl. Q module 5.5 Communication: Radio / C-mode und Mechanical water meter measuring capsule - with mounted and parameterised radio add-on module - for integration into the Q walk-by System or Q AMR System (C-mode) - Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - Dry runner, impeller wheel - MID approval - C-Mode features see page 1 - switch from C to S mode possible Radio transmission compatible with walk-by installations with WFZ166.MO, mixed operations possible (read-out requirements: Q log current ACT46). Please note! Excluded from calibration (formerly re-calibration) and buyback. Supplied in batches of 20 pieces. ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Permanent flow rate Q₃ 2.5 m 3 /h Connection interface IST (Ista) - Connection thread G 2" - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000T ,00 max. 90 C water temperature 5P 1 WMM5-001T ,00 Connection interface A34 (Allmess) - Connection thread M77 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000T ,00 max. 90 C water temperature 5P 1 WMM5-001T ,00 Connection interface MOC/MOE (Elster/ABB) - Connection thread M65 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000T-A ,00 max. 90 C water temperature 5P 1 WMM5-001T-A ,00 Connection interface MET (Brunata/Metrona HT3)- Connection thread M64 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature 5P 1 WMM5-000T-C ,00 max. 90 C water temperature 5P 1 WMM5-001T-C ,00 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 41

43 4 Water meters 4.6 Q water 4 - Mechanical measuring capsule water meters Communication: basic Mechanical water meter measuring capsule - Dry runner, impeller wheel - module shaft for retrofitting external communication modules - MID approval ALL PRICES INCL. FIXED FEE, CONFORMITY ASSESSMENT. Connection interface IST (Ista)- Connection thread G 2" - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMK10.D 40,85 max. 90 C water temperature MD 1 WMW10.D 40,85 Connection interface A34 (Allmess) - Connection thread M77 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMK10.D/ALL 51,90 max. 90 C water temperature MD 1 WMW10.D/ALL 51,90 Connection interface TE1 (Techem) - Connection thread M62 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM V00 51,90 max. 90 C water temperature MD 1 WMM V00 51,90 Connection interface MOC/MOE (Elster/ABB) - Connection thread M65 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMK10.D/ABB 41,85 max. 90 C water temperature MD 1 WMW10.D/ABB 41,85 Connection interface MET (Brunata/Metrona HT3) - Connection thread M64 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMK10.D/MET 50,00 max. 90 C water temperature MD 1 WMW10.D/MET 50,00 Connection interface HT2 (Brunata HT2/Metrona 307)- Connection thread M66 x 1 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM E001 00V00 62,10 max. 90 C water temperature MD 1 WMM E001 00V00 62,10 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 42

44 4 Water meters 4.6 Q water 4 - Mechanical measuring capsule water meters Communication: basic Connection interface MB3 (Minol) - Connection thread M76 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM J001 00V00 71,90 max. 90 C water temperature MD 1 WMM J001 00V00 71,90 Connection interface MB2 (Minol) - Connection thread M80 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM G001 00V00 71,90 max. 90 C water temperature MD 1 WMM G001 00V00 71,90 Connection interface DM1 (Deltamess TK) - Connection thread M60 x 2 - Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM T001 00V00 62,10 max. 90 C water temperature MD 1 WMM T001 00V00 62,10 Connection interface MUK (Sensus PolluMUK)- Connection thread G2 1/4" - Permanent flow rate Q ₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM V001 00V00 51,90 max. 90 C water temperature MD 1 WMM V001 00V00 51,90 Connection interface WE1 (Wehrle)- Connection thread M78 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM W001 00V00 63,90 max. 90 C water temperature MD 1 WMM W001 00V00 63,90 Connection interface WGU (Wassergeräte) - Connection thread M66 x Permanent flow rate Q₃ 2.5 m³/h max. 30 C water temperature MD 1 WMM X001 00V00 62,10 max. 90 C water temperature MD 1 WMM X001 00V00 62,10 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 43

45 4 Water meters 4.7 Q water Electronic valve- and bath meters The new electronic valve and bath meters include a connection kit for valve or bath meters as well as a Q water 5.5 IST. That means the new connection kits can be combined with every version of the Q water 5.5 with connection interface IST and connection thread G2" (S-Mode, C-Mode, hot, cold). Valve meter-connection kit for Q water 5.5 (new installation) Valve meter connection kit for electronic water meter Q water with connection interface IST - connection thread G 2" - permanent flow rate Q₃ 2.5 m³/h The connection kit includes: - Chrome-plated valve meter fittings - Centre section - Chrome-plated connection housing - Accessories for installing of the valve meter (seals, O-rings, etc.) Please note: The Q water 5.5 is not part of the connection kit. Please find the matching Q water 5.5 with connection interface IST - connection thread G 2" - permanent flow Q₃ 2.5 m³/h on page 36 (S-Mode) and page 38 (C-Mode) in the device price list. Connection set and extensions as well as rosettes are not included in the scope of the valve meter connection kit (new installation). They can be found in the accessories price list. Valve meter connection kit for Q water 5.5 5G 1 BBV ,10 Bath meter-connection kit for Q water 5.5 (new installation) Bath meter connection kit for electronic water meter Q water with connection interface IST - connection thread G 2" - permanent flow rate Q₃ 2.5 m³/h The connection kit includes: - Chrome-plated bath meter fittings - Centre section - Chrome-plated connection housing - Accessories for installing of the bath meter (seals, O-rings, etc.) Please note: The Q water 5.5 is not part of the connection kit. Please find the matching Q water 5.5 with connection interface IST - connection thread G 2" - permanent flow Q₃ 2.5 m³/h on page 36 (S-Mode) and page 38 (C-Mode) in the device price list. Bath meter connection kit for Q water 5.5 5G 1 BBV ,40 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 44

46 4 Water meters 4.7 Q water Electronic valve- and bath meters Replacement connection kit for valve and bath meter for Q water 5.5 Replacement connection kit for electronic water meter Q water with connection interface IST - connection thread G 2" - permanent flow rate Q₃ 2.5 m³/h for the replacement of electronic valve and bath meters from QUNDIS of the WMx36.DVN series The connection kit includes: - Chrome-plated connection housing - Centre section - Accessories for installing of the connection kit (seals, O-rings, etc.) Please note: The Q water 5.5 is not part of the connection kit. Please find the matching Q water 5.5 with connection interface IST - connection thread G 2" - permanent flow Q₃ 2.5 m³/h on page 36 (S-Mode) and page 38 (C-Mode) in the device price list. Replacement connection kit for Q water 5.5 5G 1 BBV ,10 Hot water cost allocator connection kit for Q water 5.5 Hot water cost allocator connection kit for existing retrofitted hot water cost allocators. The connection housing takes up the space of the TZ90 and is designed for mounting of a Q water 5.5 with connection interface IST and connection thread G2 The connection kit includes: - Chrome-plated connection housing - Accessories for installing of the connection kit Please note: The Q water 5.5 is not part of the connection kit. Please find the matching Q water 5.5 with connection interface IST - connection thread G 2" - permanent flow Q₃ 2.5 m³/h on page 36 (S-Mode) and page 38 (C-Mode) in the device price list. Hot water cost allocator connection kit for Q water 5.5 5G 1 BBV ,10 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 4, page 45

47 5 Smoke detector Smoke detectors serve to detect and signal the development of smoke and/or heat. DIN the application standard for smoke detectors - regulates the planning, installation, operation and servicing of smoke detectors in residential houses, flats and rooms used for residence purposes on the (German) national level. DIN EN is the European product standard for smoke detectors. This describes the performance criteria and test methods used for the devices. In Germany, the obligation to equip residential buildings with smoke alarms is regulated by the building laws of the different regional states. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 5, page 47

48 5 Smoke detector 5.1 Q smoke - Smoke detector standalone - Hekatron Genius H-N The Q smoke Genius H smoke alarm alerts early-on and reliably during smouldering fires and open flames with smoke development. The intelligent evaluation electronics prevents false alarms and efficient battery management makes battery service lives of 10 years possible. Product details: - 85 db alarm signal at a distance of 3 m - User-friendly test stop button - Permanently installed lithium battery for a service life of 10 years (removal of battery not possible) - Automatic self-monitoring - Active contamination prediction - Alarm memory - Electronic dismantling detection - Made in Germany Communication: basic Smoke detector standalone - Genius H-N incl. mounting material Please note: You can only order the radio smoke detector in batch sizes of 30 pieces. Standalone Genius H-N, sale and delivery in packing units of 30 units each H1 1 PU SDT5-ZZ ,70 Installation material Suitable installation material can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 5, page 48

49 5 Smoke detector 5.2 Q smoke Smoke detector radio The new radio smoke detector Q smoke 5.5 ranks among the high-quality products on the smoke detector market. It unifies innovative electronics with comprehensive functions, minimum device size and the highest degree of reliability. Thanks to an integrated radio module the unit status and any possible status messages can be checked at any time. The 3-colour LED display provides information on the device status to the tenant on site. Product details: - Automatic operability after screwing into the socket - 85 db alarm signal at a distance of 3 m - User friendly test stop button - Permanently installed lithium battery for a service life of 10 years (removal of battery not possible) - Suitable for bedrooms thanks to LED deactivation and suppression of the status messages from 9 pm to 7 am - Contamination compensation and contamination prediction - Transmission of the device status via radio through Q walk-by or Q AMR into the Smart-Metering Platform (Q SMP) - Comprehensive evaluation facilities of the device status Communication: AMR / S-mode S-mode features - transmission of AMR data telegrams - every 4 hours, 24 hours a day - switch from S to C mode not possible The send mode is preconfigured at the factory based on the order and cannot be changed later onsite. Incl. mounting material. Please note: You can only order the radio smoke detector in batch sizes of 30 pieces. Radio (S-mode AMR), sale and delivery in packing units of 30 units each H2 1 PU SDT ,70 Communication: Radio / C-mode und - C-mode features see page 1 - switch from C to S mode not possible The send mode is preconfigured at the factory based on the order and cannot be changed later onsite. Incl. mounting material. Please note: You can only order the radio smoke detector in batch sizes of 30 pieces. Radio (C-mode), sale and delivery in packing units of 30 units each H2 1 PU SDT ,70 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 5, page 49

50 6 Further system components data readout walk-by walk-by recording of consumption data AMR wireless readout of consumption data Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 6, page 51

51 6 Further system components data readout 6.1 Q module Add-on radio module for mechanical water meters Communication: Radio / S-mode und Radio add-on modules suitable for radio prepared water meters of type Modularis (suitable for Q water 4 mechanical water meters) Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - S-Mode features see page 1 - switch from S to C mode possible Radio transmission compatible with WFZ166.MO and WFZ16.MO, mixed operation possible! Please note! Supplied in batches of 10 pieces. Radio (S-mode) 5T 1 RWM5-000N ,50 Communication: Funk / C-Mode und Radio add-on modules suitable for radio prepared water meters of type Modularis (suitable for Q water 4 mechanical water meters) Standard version: Due date (additional options are possible on request or can be changed onsite with the Q suite 5 software) - C-mode features see page 1 - switch from C to S mode possible Radio transmission (walk-by) compatible with WFZ166.MO, mixed operation possible! (read-out requirements: Q log current ACT46). Please note! Supplied in batches of 10 pieces. Radio (C-mode) 5T 1 RWM5-000T ,50 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 6, page 52

52 6 Further system components data readout 6.1 Q module 5 - Add-on radio module for mechanical water meters Communication: walk-by / S-mode Radio add-on modules suitable for radio prepared water meters of type Allmess (suitable for series MK +m, V +m) Parameter setting through software ACT20 walk-by (S-mode); 10pcs. per package unit walk-by (S-mode); single package unit 5T 1 PU WFZ166.AL 713,00 5T 1 WFZ166.AL-1 74,20 Communication: AMR / S-mode Radio add-on modules suitable for radio prepared water meters of type Allmess (suitable for series MK +m, V +m) Parameter setting through software ACT20 AMR (S-mode); 10pcs. per package unit AMR (S-mode); single package unit 5T 1 PU WFZ16.AL 713,00 5T 1 WFZ16.AL-1 74,20 Additional modules for radio prepared mechanical water meters on request. Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 6, page 53

53 6 Further system components data readout 6.2 Q module Radio add-on module for heat meters Communication: Radio / S-mode und Radio add-on module suitable for heat meters of the series Q heat 5 and calculator units R 20/21 The serial number, consumption and due date values are readout of the heat meter directly via an optical interface, which means parameter setting is not required for these data. - S-Mode features see page 1 - switch from S to C mode possible Radio transmission compatible with WFZ166.Ox and WFZ16.Ox, mixed operation possible! Please note! Supplied in batches of 10 pieces. Radio (S-mode) 5U 1 RHM5-00AN-0000 Z ,80 Communication: Radio / C-mode und Radio add-on module suitable for heat meters of the series Q heat 5 and calculator units R 20/21 The serial number, consumption and due date values are readout of the heat meter directly via an optical interface, which means parameter setting is not required for these data. - C-Mode features see page 1 - switch from C to S mode possible Radio transmission (walk-by) compatible with WFZ166.Ox, mixed operation possible! (read-out requirements: Q log current ACT46). Please note! Supplied in batches of 10 pieces. Radio (C-mode) 5U 1 RHM5-00AT-0000 Z ,80 Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 6, page 54

54 6 Further system components data readout 6.3 Q pulse - Pulse adapter Communication: walk-by / S-mode Impulse adapter for the integration of consumption meters with impulse output in the walk-by system suitable for meters with impulse output from different manufacturers; two meters can be connected Manipulation detection, if impulse acquisition is interrupted or short-circuited. This function must be supported by the consumption meter connected (NAMUR). Water meters, heat meters, heat/cold meters, gas meters, steam meters, oil meters with impulse output and electric meters with S0 interface can be recorded (impulse converter required). walk-by (S-mode); Impulse adapter MK 1 AEW ,90 Communication: AMR / S-mode Impulse adapter for the integration of consumption meters with impulse output in the AMR system suitable for meters with impulse output from different manufacturers; two meters can be connected Manipulation detection, if impulse acquisition is interrupted or short-circuited. This function must be supported by the consumption meter connected (NAMUR). Water meters, heat meters, heat/cold meters, gas meters, steam meters, oil meters with impulse output and electric meters with S0 interface can be recorded (impulse converter required). AMR (S-mode); Impulse adapter MK 1 AEW ,00 Application Software and Service Tools Application Software and Service Tools can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 6, page 55

55 7 Further system components data readout Q AMR 7.1 Q node 5 - Network nodes Communication: AMR / S-mode The network nodes Q node 5 come with an improved antenna capacity. This means that data from more consumption metering devices can be received even in difficult wireless conditions. An building-dependent reduction of the number of nodes per property is also possible. Q node 5 is compatible with existing network nodes and gateways of the series WTx16 and gateways of the series Q gateway 5. Local readout possible through the USB programming adapter RNNP-H or through the M-bus interface and, in the RNN5-000M version, also through the RS232 interface. Please note: The Q node 5 currently receives radio telegrams in S-mode. Q node 5 with battery supply Q node 5 with power supply and RS232 interface 5X 1 RNN5-000M ,50 5X 1 RNN5-000M , Q gateway 5 - Gateways Communication: AMR The function of the new Q gateway 5 is the remote readout of a Q AMR network, combining fully automatic remote data readout operations with the monitoring of metering devices and the overall system. The Q gateway 5 can read out up to metering devices and multiple AMR networks. Data transmission is by mobile communication (GPRS/EDGE/UMTS/HSPA). The Q gateway 5 is supplied ex works with a SIM card. All administrative and data recording operations are managed via the QUNDIS Smart Metering Platform (Q SMP). Please note: The Q gateway 5 is sold only in combination with a QUNDIS Gateway Service (GSD) contract for a minimum contractual period of five years. Q gateway 5 with battery supply Q gateway 5 with power supply 5Y 1 RNG5-N00R x 490,00 5Y 1 RNG5-N00R x 590,00 Application Software and Service Tools Application Software and Service Tools can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 7, page 56

56 7 Further system components data readout Q AMR 7.3 Overview of tariffs Gateway Service Description (GSD) data supply - twice per month data supply - once a week data supply - daily Qty. Part no. Price ( ) / year 1 QGW-A ,88 1 QGW-A ,88 1 QGW-A ,88 You will find the corresponding descriptions of features in the QUNDIS Download Center (QDC). 7.4 The solution package for small Q AMR systems (max. 80 devices) - Readout of max. 80 metering devices from 1 AMR network - Data delivery 1 x per month (tariff: QGW-A ) for an annual price of One Q gateway 5 as well as one Q node 5 for the package price - Upgrade to standard tariff possible if max. number of devices is exceeded - Minimum contract period 5 years Q gateway 5 + Q node 5 for small systems data supply - once a month / price per year 5Y 1 RNG5-N00R ,00 1 QGW-A ,00 You will find the corresponding description of features in the QUNDIS Download Center (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 7, page 57

57 8 Further system components data readout Q M-Bus Q M-Bus systems are used for recording consumption data primarily from heat meters and water meters. Compared to radio systems, wired systems make sense wherever meters have to transmit instantaneous values or where a few meters for central recording are spread over a large area. In addition to the actual meters for heat and water, QUNDIS also supplies impulse input modules that provide data from devices with an impulse output for the Q M-Bus system. Central units, level converters and remote displays round off the product range. wired remote meter readout Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 8, page 59

58 8 Further system components data readout Q M-Bus 8.1 Q module - M-Bus - Add-on module for mechanical water meter M-Bus-modul for mechanical water meters of type Modularis (suitable for Q water 4 mechanical water meters) M-Bus-add-on module MK 1 MWMH Z0V10 49, Q module - M-Bus - Add-on modules for heat meters M-Bus modul for heat meter suitable for heat meters of the series Q heat 5 and calculator units R 20/21 (Heat meter with integrated M-bus module, see chapter 2.3) M-Bus-add-on module MK 1 MHM5-00A ,15 M-Bus-add-on module with extended data telegram MK 1 MHM5-00A , Q pulse - M-Bus - impulse input module M-Bus-impulse input module with two inputs for the connection of up to two metering devices with impulse output (Reed contact with or without Namur circuitry), e.g. suitable for gas, water or oil meters The M-Bus Connection set included in the scope of supply. with 2 inputs B1 1 AEW ,00 Application Software and Service Tools Application Software and Service Tools can be found in our digital accessories price list (PDF) at in the section service/downloads-and-information/product-information and in Excel format in the Customer Centre (QDC). Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 8, page 60

59 9 General terms and conditions 9.1 General terms and conditions Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 9, page 61

60 9.1 General terms and conditions Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 9, page 62

61 9.1 General terms and conditions Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 9, page 63

62 9.1 General terms and conditions Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 9, page 64

63 9.1 General terms and conditions Our conditions of delivery and installation apply, subject to error and change, the prices do not include VAT chapter 9, page 65

Price list 2016 Devices

Price list 2016 Devices Price list 2016 Devices Product range Chapter Chapter name Page 1 Heat cost allocator - Q caloric 5 1 1.1 New installation - Standard exchange - Conversion installation (P2 + AL2) 2 2. Compact heat meters

More information

Heat meter Q heat 5 US

Heat meter Q heat 5 US Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement

More information

Electronic device for recording the share of heat output by radiators.

Electronic device for recording the share of heat output by radiators. Data sheet / 7.5.2018 - V 2.6 Q caloric 5.5 Electronic device for recording the share of heat output by radiators. In terms of measuring technology, the Q caloric 5.5 is 100% compatible with the Q caloric

More information

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1 Data sheet / 3.3.2017 - V 2.1 Electronic water meter Q water 5.5 Electronic MID-conform water meter for determining water consumption in water supply systems The electronic water meter Q water 5.5 has

More information

ultego III smart plus

ultego III smart plus Ultrasonic heating and cooling meter ultego III smart plus Residential ultego III smart plus Technical description 32 22 101 001 a Date: 07.04.2017 ista Middle East FZE Outstanding features 2/26 Outstanding

More information

ULTRAHEAT T230 ULTRACOLD T230

ULTRAHEAT T230 ULTRACOLD T230 Ultrasonic heating and cooling meter T230 Residential ULTRAHEAT T230 ULTRACOLD T230 Technical description 32 18 101 001 d Date: 15.01.2017 Landis+Gyr GmbH Outstanding features 2/26 Outstanding features

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS Design IEC870-6 EW447A0100 26757950 2252 00.02 Type440 Umgebungsklasse: C env: 5 C...105 C Δp: 3K...100K q: 1,5m 3 /h q: 0,03m 3 /h q: 3,0m 3 /h M-Bus kwh 2002 er: 5 C...90 C DN15 PN16 Rücklauf Pt500 Kl.

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Static Meters Portfolio ULTRAHEAT/ ULTRACOLD and ULTRAWATER The best of Landis+Gyr Ultrasonic Static Meters, for

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters Deltamess TKS-WM compact heat meter 1 Contents Safety and warranty... 3 Radio system... 3 Lithium

More information

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters 5 338 SIEMECA Electronic Heat and Cooling Meters WFR WFN Electronic, mains-independent meters to acquire the heat and cooling energy consumption in autonomous heating, cooling and domestic hot water plants.

More information

Electronic Heating Energy Meters

Electronic Heating Energy Meters 5 333 SIEMECA Electronic Heating Energy Meters WFM... WFQ... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage and

More information

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet SVM F27 / C27 Ultrasonic BTU meter for heating or cooling Data sheet Application field F27/C27 is a BTU meter for debiting and monitoring energy consumption (F27 for heating and C27 for cooling). F27/C27

More information

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h APPLICATION Ray is a fully electronic multi-jets compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors.

More information

SONOMETER TM 1000 Ultrasonic compact heat meter

SONOMETER TM 1000 Ultrasonic compact heat meter SONOMETER TM 1000 Ultrasonic compact heat meter Description/Application The SONOMETER 1000 is a static compact heat meter with fully electronic measurement based on the ultrasonic principle. It is especially

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Our system solutions for consumption data recording. Flexible compatible variable

Our system solutions for consumption data recording. Flexible compatible variable Our system solutions for consumption data recording. Fleible compatible variable Innovation rooted in tradition. The QUNDIS Group The systematic QUNDIS principle. Consumption metering from a single source

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

SonoSelect 10 and SonoSafe 10 Energy Meters

SonoSelect 10 and SonoSafe 10 Energy Meters SonoSelect 10 and SonoSafe 10 Energy Meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

INFOCAL 8 Energy calculator

INFOCAL 8 Energy calculator Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially

More information

HEAT COST ALLOCATORS HYDROCLIMA OPTO HYDROCLIMA RFM. Remote reading heat cost allocators. Optical reading heat cost allocators

HEAT COST ALLOCATORS HYDROCLIMA OPTO HYDROCLIMA RFM. Remote reading heat cost allocators. Optical reading heat cost allocators HEAT COST ALLOCATORS HYDROCLIMA RFM Remote reading heat cost allocators HYDROCLIMA OPTO Optical reading heat cost allocators In recent years, Energy savings and the Environment protection have become among

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron 1 Application and function This heat meter or heat / cooling meter is designed for the measurement of the

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

RF converter WTX660-E05060

RF converter WTX660-E05060 RF converter WTX660-E05060 The WTX660.. RF converter receives and processes data from heat cost allocators, heat and water meters within a M-bus radio system. Storage for up to 500 metering devices Repeater

More information

Ultrasonic heat and cooling energy meters

Ultrasonic heat and cooling energy meters Ultrasonic heat and cooling energy meters UH50.. Ultrasonic heat and cooling energy meters to measure flow and energy in hydronic heating or refrigerant circuits. Available as heat, cooling energy, or

More information

ULTRASONIC D. Compact ultrasonic heat meter

ULTRASONIC D. Compact ultrasonic heat meter ULTRASONIC D Compact ultrasonic heat meter Applications ULTRASONIC D is a compact ultrasonic heat meter used for measuring energy in heating and cooling plants in facility management systems as well as

More information

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet SVM F27 Compact Ultrasonic heatmeter Data sheet Application field F27 is a heat meter for debiting and monitoring heat energy consumption. F27 is a flexible compact heat meter with an ultra sonic flow

More information

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

Device Manual Chapter 4.1-R optosonic u 3 radio net

Device Manual Chapter 4.1-R optosonic u 3 radio net Chapter 4.1-R optosonic u 3 radio net L.83.0072 - Release 8.0.1 CH 2013 Nur für den internen Gebrauch For internal use only Uniquement pour utilisation interne http://www.ista.com Table of contents 1 Device

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

The innovative way forward symphonic sensor net radio system

The innovative way forward symphonic sensor net radio system The innovative way forward symphonic sensor net radio system Radio system technology The symphonic sensor net radio system Applications at a glance Heat cost allocation meter doprimo 3 radio net Smoke

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

microclima/sensostar 2/2+ MSH

microclima/sensostar 2/2+ MSH Installation and Operating Instructions Thermal Energy Meter (Compact Heat Meter, Combined Heat/Cooling Energy Meter) microclima/sensostar 2/2+ MSH Model MSH DE-07-MI004-PTB001 (MID heat) Model QStar DE-08-MI004-PTB005

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

Electronic Heat Cost Allocator GRADUS User Manual

Electronic Heat Cost Allocator GRADUS User Manual Electronic Heat Cost Allocator GADUS User Manual ev. 1 02/15 Table of Contents 1 APPLICATION AND FUNCTION... 3 2 CONTENTS OF PACKAGE... 3 3 GENEAL INFOMATION... 3 4 GENEAL MOUNTING INFOMATION... 3 5 DISPLAY

More information

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat) Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat) 1 Application and function This heat meter or

More information

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling) Installation and Operating Instructions Calculator with Ultrasonic flow sensor: Heat Meter, Cooling Meter, Combined Heat / Cooling Meter US-W/V US-S/FFL Certificate No.: DE-09-MI004-PTB018 (MID heat) /

More information

USB Meter Reader. Data sheet. For reading Kamstrup consumption meters

USB Meter Reader. Data sheet. For reading Kamstrup consumption meters Data sheet USB Meter Reader For reading Kamstrup consumption meters Reading system for reading Kamstrup MULTICAL meters via M-Bus and wireless M-Bus Mode C1, 434 MHz radio as well as flowiq water meters

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-R Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values). Operating Instructions Communication Interfaces 1 Interfaces and Options 1.1 Optical (infrared) interface For communication with the optical interface an optocoupler and the Device Monitor software are

More information

User s Manual. F2 Calculator. A metering component for thermal energy applications

User s Manual. F2 Calculator. A metering component for thermal energy applications User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007 1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer

More information

THYRO-P TM THYRO-P TM VSC. Digital thyristor power controller (SCR) NEW

THYRO-P TM THYRO-P TM VSC. Digital thyristor power controller (SCR) NEW THYRO-P TM THYRO-P TM VSC Digital thyristor power controller (SCR) NEW THYRO-P TM THYRO-P TM VSC Digital thyristor power controller (SCR) The Thyro-P is the result of consistent implementation of more

More information

Annex to application for conformity assessment of Heat meters in accordance with MID

Annex to application for conformity assessment of Heat meters in accordance with MID This is Annex No. 1 Dated: To application dated: Company Signed Documentation required (to be completed by applicant) for testing of Heat meter or sub-assemblies Note: All documentation must be equipped

More information

HDU-SF (Horizontal Distribution Units - Single Flat)

HDU-SF (Horizontal Distribution Units - Single Flat) MAKING MODERN LIVING POSSIBLE Service Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language

More information

SN+ MID MASTER + APPLICATION WATER METERS

SN+ MID MASTER + APPLICATION WATER METERS SMART THINKING WATER METERS MASTER + SINGLE-JET DRY WATER METERS DN25, DN32, DN40 MID R 100 Master+ is a single-jet dry meter intended to measurement of quantity of consumption. Thank to modern construction

More information

Ultrasonic heat and cooling energy meters

Ultrasonic heat and cooling energy meters s 5 324 Ultrasonic heat and cooling energy meters UH50.. Ultrasonic heat and cooling energy meters to measure flow and energy in hydronic heating or refrigerant circuits. Available as heat, cooling energy,

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information Instruction SONOMETER 1100 Ultrasonic compact energy meter 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy meter...2 4.0 Installation

More information

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter ata Sheet 902815 Page 1/13 JUMO trans T100 Screw-in RT Temperature Probe with/without Transmitter For temperatures between -50 and +260 C RoHS conformity for EU and China Configuration with setup program

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

Residential Water Meters

Residential Water Meters EnergyMetering Residential Water Meters Multi-jet wet dial meters Positive displacement meters All that counts. Multi-jet wet dial meters Options of the D-register at a glance Register and smart metering

More information

SONOMETER 2000 Ultrasonic heat meter

SONOMETER 2000 Ultrasonic heat meter SONOMETER 2000 Ultrasonic heat meter Description/Application The SONOMETER 2000 is an ultrasonic heat meter especially designed for measuring the water and energy consumption in district heating networks.

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation 07EN March 0 Sanitary water meters GE55- series 00A/ Qualitative error diagram % error 5 0 - - - - -5 Q Q Q Q GE55Y90 GE55Y9 Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Description Single-jet dry

More information

EDC communication module

EDC communication module EnergyMetering EDC communication module Water meter clip-on module for secure remote reading for integration of water meters in Smart Metering AMR/AMI Systems All that counts. EnergyMetering EDC communication

More information

MULTICAL 403. Data sheet

MULTICAL 403. Data sheet - Data sheet MULTICAL 403 Programmable data logger with AMR Configurable M-Bus modules with logger reading On-site configuration via front keys Highly flexible modular design Pulse inputs and pulse outputs

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

MULTICAL 302 DATA SHEET

MULTICAL 302 DATA SHEET MULTICAL 302 DATA SHEET On-site configurable as to inlet and outlet PN25 metal flow sensor, approved up to 130 C Small pressure loss, all flow sizes below 0.1 bar Dynamic range up to 1:1600 from start

More information

PWB encoders GmbH Am Goldberg 2 D-99817 Eisenach Germany Phone: +49 3691 72580-0 Fax: +49 3691 72580-29 info@pwb-encoders.com www.pwb-encoders.com 1 of 9 Description The ME22 is a reliable low cost optical

More information

wprime TM Series 280W-CI ULTRASONIC WATER METER

wprime TM Series 280W-CI ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Optical encoder MEC22 HR

Optical encoder MEC22 HR Optical encoder MEC22 HR Description The MEC22 HR is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square

More information

User manual. paper moisture meter RH5.1 with sword-sensor

User manual. paper moisture meter RH5.1 with sword-sensor User manual paper moisture meter RH5.1 with sword-sensor version 2.0_en Schaller GmbH 2012 User manual Positioning the instrument Insert the sword-sensor into the stack for only approx. 10 cm, and push

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual SVM F2 Calculator A small competent calculator for compact or wall montage Users manual Users manual F2 1 INSTALLATION... 5 1.1 AT DELIVERY... 5 1.2 CONNECTIONS... 6 2 MOUNTING... 7 2.1 MOUNTING ON A

More information

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility Data sheet MULTICAL 603 The future-proof heat and cooling meter with full flexibility Fully programmable data logger with minute loggers 2 second integration interval 16 years battery lifetime at a reading

More information

SONO 1500 CT Ultrasonic flow sensor

SONO 1500 CT Ultrasonic flow sensor Data sheet SONO 1500 CT Ultrasonic flow sensor Description/Application MID examination certificate no.: DE-09-MI004-PTB011 The SONO 1500 CT is an ultrasonic flow sensor especially designed for heating,

More information

Solids Content Sensor OUS 41 / OUS 41-W

Solids Content Sensor OUS 41 / OUS 41-W Technical Information TI 177e00/12.00 No. 51505145 Solids Content Sensor OUS 41 / OUS 41-W Process and immersion sensor for service water and solids content measurement based on multi-channel technology,

More information

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0) Installation & User Guide Multical 402 (Heating & Cooling) Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Installation and User Guide MULTICAL 402 Kamstrup A/S Industrivej 28, Stilling

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

EYL225: nova225, Compact automation station

EYL225: nova225, Compact automation station SAUTER EY3600 PDS 92.525 en Product Data Sheet EYL225 EYL225: nova225, Compact automation station The nova225 compact automation station can be connected with various outlying units, so-called field modules.

More information

Alpha IP: Room Control Unit Radio Analog

Alpha IP: Room Control Unit Radio Analog Alpha IP: Room Control Unit Radio Analog The Alpha IP Room Control Unit Radio Analog registers the room temperature in the assigned heating zone and regulates it via connected Alpha IP Radiator Thermostats

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

( F L O W I Z F A M I L Y )

( F L O W I Z F A M I L Y ) THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4

More information

Electromotoric actuators

Electromotoric actuators s 4 540 ACVATIX Electromotoric actuators for Combi valves VPI45.., DN40/50 SQD65 operating voltage AC 230 V, 3-position control signal operating voltage AC 24 V, 3-position control signal SQD65 operating

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Energy Technology. AMR Systems

Energy Technology. AMR Systems Energy Technology AMR Systems Bus systems Wireless M-Bus radio system LPWAN radio system (LoRaWAN, SIGFOX) Stationary GSM system Electronic components Software solutions 1 2 ZENNER AMR Systems Flexible,

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies A T u n e d M e a s u r e A Member of the Integrated Metering Technologies AMR Ready ARAD 3G easy connection to any automated metering reading system. No Moving Parts No wear - Therefore low maintenance.

More information

MID MP-01, MP WATER MEASUREMENT

MID MP-01, MP WATER MEASUREMENT FROM METERING TO DATA MANAGEMENT WATER MP-0, MP30-0 PROPELLER WATER METER WITH VERTICAL ROTOR AXIS DN40 DN0 MID APPROVED MP-0 is a dry Woltmant propeller water meter with the vertical rotor axis which

More information

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany 522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524

More information