1 TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: NTT docomo P-05C To: OET Bulletin 65 Supplement C: ( ) Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 supersedes all previous versions This Test Report Is Issued Under The Authority Of Chris Guy, Head of Global Approvals: (APPROVED SIGNATORY) pp Checked By: Richelieu Quoi (APPROVED SIGNATORY) Issue Date: 24 March 2011 Test Dates: 15 March to 24 March 2011 This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested.

2 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 This page has been left intentionally blank. Page: 2 of 169 RFI Global Services Ltd.

3 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 TABLE OF CONTENTS 1. Customer Information Equipment Under Test (EUT) Test Specification, Methods and Procedures Deviations from the Test Specification Operation and Configuration of the EUT during Testing Summary of Test Results Measurements, Examinations and Derived Results Measurement Uncertainty Appendix 1. Test Equipment Used Appendix 2. Measurement Methods Appendix 3. SAR Distribution Scans Appendix 4. Photographs Appendix 5. Validation of System Appendix 6. Simulated Tissues Appendix 7. DASY4 System Details Page: 3 of 169 RFI Global Services Ltd.

4 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Customer Information Company Name: Address: Panasonic Mobile Comms Dev of Europe Ltd Panasonic House Willoughby Road Bracknell Berkshire RG12 8FP United Kingdom Page: 4 of 169 RFI Global Services Ltd.

5 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Equipment Under Test (EUT) 2.1. Identification of Equipment Under Test (EUT) Description: Mobile Handset Brand Name: Model Name or Number: NTT docomo P-05C Serial Number: None Stated (Customer Label: Sample C4) IMEI Number: Hardware Version Number: Software Version Number: Hardware Revision of GSM Module: Software Revision of GSM Module: FCC ID Number: Country of Manufacture: Rev C B-D11SL D11SL1_Cv Not Applicable Not Applicable UCE211039A Japan Date of Receipt: 14 March Description of EUT The equipment under test was a Dual mode mobile handset operating in the UMTS FDD V, PCS1900 band, WiFi 2450 band Bluetooth band and RFID. The EUT operates on UMTS Release 5 HSDPA 850 MHz Band, GPRS class 10, b/g/n and Bluetooth 2400 MHz Band Modifications Incorporated in the EUT There were no modifications incorporated in the EUT. Page: 5 of 169 RFI Global Services Ltd.

6 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Accessories The following accessories were supplied with the EUT during testing: Description: Battery Brand Name: NTT Model Name or Number: P20* Serial Number: Cable Length and Type: Country of Manufacture: Connected to Port None Stated Not Applicable None Stated 3 point contact Description: Personal Hands-Free Brand Name: NTT docomo Model Name or Number: Stereo Earphone Set 01 Serial Number: None Stated Cable Length and Type: ~1.8m / multi-core Country of Manufacture: None Stated Connected to Port AV Out Port Unique to Manufacturer Description: Brand Name: Model Name or Number: Serial Number: Cable Length and Type: Country of Manufacture: Connected to Port Micro-SD Memory Card Generic None Stated None Stated Not applicable None Stated Dedicated micro-sd card port Page: 6 of 169 RFI Global Services Ltd.

7 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Support Equipment The following support equipment was used to exercise the EUT during testing: Description: Wireless Communication Test Set Brand Name: Agilent Model Name or Number: 8960 Series 10 Serial Number: Cable Length and Type: Connected to Port: GB ~4.0m Utiflex Cable RF (Input / Output) Air Link Description: Wireless Communication Test Set Brand Name: Rohde & Schwarz Model Name or Number: CMU200 Serial Number: Cable Length and Type: ~4.0m Utiflex Cable Connected to Port: RF (Input / Output) Air Link Description: Communication Test Set Brand Name: Will tek Model Name or Number: 4202S Serial Number: Cable Length and Type: ~4.0m Utiflex Cable Connected to Port: RF (Input / Output) Air Link Page: 7 of 169 RFI Global Services Ltd.

8 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Additional Information Related to Testing Equipment Category UMTS FDD V / PCS1900/GPRS1900 /Bluetooth / WiFi802.11b/g/n /RFID Type of Unit Intended Operating Environment: Transmitter Maximum Output Power Characteristics: Portable Transceiver Within UMTS FDD V, GSM and WiFi Coverage UMTS Band V PCS1900 WiFi802.11b/g/n Bluetooth Communication Test Set was configured to allow the EUT to transmit at a maximum power of up to 24dBm. Communication Test Set was configured to allow the EUT to transmit at a maximum power of up to 30dBm. EUT setup in test mode to allow the EUT to transmit at a maximum power of up to 15dBm. ~2dBm Transmitter Frequency Range: UMTS Band V (826 to 847) MHz Transmitter Frequency Allocation of EUT When Under Test: Modulation(s): Modulation Scheme (Crest Factor): Type: Length: Number of Positions: PCS1900 WiFi802.11b/g/n Channel Number (1850 to 1910) MHz (2412 to 2462) MHz Channel Description Frequency (MHz) 4132 Low Middle High Low Middle High Low Middle 2437 QPSK (UMTS / HSDPA):0 Hz GMSK (GSM / GPRS): 217 HZ DBPSK, CCK (WiFi): 0 Hz QPSK (UMTS FDD/HSDPA):1 GMSK (GSM): 8.3 GMSK (GPRS): 4 DBPSK, CCK (WiFi): 1 Internal Power Supply Requirement: 3.7V Battery Type(s): Unknown 2 fixed (GSM and Wi-Fi) With TV extendable and retractable antenna Li-ion Page: 8 of 169 RFI Global Services Ltd.

9 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Test Specification, Methods and Procedures 3.1. Test Specification Reference: OET Bulletin 65 Supplement C: ( ) Title: Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. To determine whether the equipment met the basic restrictions as defined in Purpose of Test: OET Bulletin 65 Supplement C: ( ) using the SAR averaging method as described in the test specification above Methods and Procedures Reference Documentation The methods and procedures used were as detailed in: Federal Communications Commission, Evaluating compliance with FCC Guidelines for human exposure to radio frequency electromagnetic fields, OET Bulletin 65 Supplement C, FCC, Washington, D.C, 20554, Thomas Schmid, Oliver Egger and Neils Kuster, Automated E-field scanning system for dosimetric assessments, IEEE Transaction on microwave theory and techniques, Vol. 44, pp , January Neils Kuster, Ralph Kastle and Thomas Schmid, Dosimetric evaluation of mobile communications equipment with know precision, IEICE Transactions of communications, Vol. E80-B, No.5, pp , May KDB D01 Mobile Portable RF Exposure v04 KDB D01 SAR Handsets Multi Xmiter and Ant v01r05 KDB D01 SAR test for 3G devices v02 KDB D01 SAR measurement Procedure for a/b/g Transmitters v01r Definition of Measurement Equipment The measurement equipment used complied with the requirements of the standards referenced in the methods & procedures section above. Appendix 1 contains a list of the test equipment used. Page: 9 of 169 RFI Global Services Ltd.

10 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Deviations from the Test Specification Test was performed as per KDB D01 Mobile Portable RF Exposure v04, KDB D01 SAR Handsets Multi Xmiter and Ant v01r05, according to the handset procedures in IEEE Std , OET Bulletin 65 Supplement C and the specific FCC test procedures. 3G Body SAR test was performed in the middle channel as the measured SAR levels were < 0.8 W/kg, where the transmission band corresponding to all channels were 100 MHz. Testing for the other channels were not required as stated in KDB D01. SAR test was performed in the highest output channel for WLAN as the measured SAR levels were < 0.8 W/kg, where the transmission band corresponding to all channels were 100 MHz. Testing for the other channels were not required as stated in KDB D01. Simultaneous transmission was not evaluated as the sum of the individual SAR for WWAN and WLAN was < 0.8 W/kg and the antenna-to-antenna distance was greater than 5 cm. Page: 10 of 169 RFI Global Services Ltd.

11 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Operation and Configuration of the EUT during Testing 5.1. Operating Modes The EUT was tested in the following operating mode(s) unless otherwise stated: PCS1900 Call allocated mode with Communication Test Set configured to allow the EUT to transmit at a maximum power of up to 30 dbm. GPRS1900 Data allocated mode with Communication Test Set configured to allow the EUT to transmit at a maximum power of up to 30 dbm. UMTS Band V 12.2kbps with test loop mode 1 and TPC bits configured to all "1's" and Communication Test Set configured to allow the EUT to transmit at a maximum power of up to 24 dbm. UMTS FDD V - RMC 12.2kbps + HSDPA With Test loop mode 1 and TPC bits configured to all "1's", Sub-test 1and Communication Test Set configured to allow the EUT to transmit at a maximum power of up to 24 dbm. WiFi b/g/n Data allocated test mode using manufacturer customised software OMTN2 Ver It was setup in test mode to allow the EUT to transmit at a maximum power of up to 15dBm. WLAN SAR test was performed on the middle channel as the measured values were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC-2. The overall worst case configuration on the middle channel using 1 Mbps for b was also evaluated on middle channel using 6 Mbps for 802,11g and 6.5 Mbps for n. Page: 11 of 169 RFI Global Services Ltd.

12 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Configuration and Peripherals The EUT was tested in the following configuration(s) unless otherwise stated: Standalone Battery Powered EUT tested in Head and Body-worn configuration. The applied configurations for body-worn orientations where the corresponding edge(s) is closest to the user with the most conservative exposure condition Head Configuration a) The EUT was placed in a normal operating position with the centre of the ear-piece aligned with the ear canal on the phantom. b) With the ear-piece touching the phantom the centre line of the EUT was aligned with an imaginary plane (X and Y axis) consisting of three lines connecting both ears and the mouth. c) For the cheek position the EUT was gradually moved towards the cheek until any point of the mouth-piece or keypad touched the cheek. d) For the tilted position the EUT was positioned as for the cheek position, and then the horizontal angle was increased by fifteen degrees (the phone keypad was moved away from the cheek by fifteen degrees). e) SAR measurements were evaluated at maximum power and the unit was operated for an appropriate period prior to the evaluation in order to minimise the drift. f) The device was keyed to operate continuously in the transmit mode for the duration of the test. g) The location of the maximum spatial SAR distribution (hot spot) was determined relative to the EUT and its antenna. h) The EUT was transmitting at full power throughout the duration of the test powered by a fully charged battery. Body Configuration a) The EUT was placed in a normal operating position where the centre of EUT was aligned with the centre reference point on the flat section of the SAM phantom. b) With the EUT touching the phantom at an imaginary centre line. The EUT was aligned with a marked plane (X and Y axis) consisting of two lines. c) For the touch-safe position the EUT was gradually moved towards the flat section of the SAM phantom until any point of the EUT touched the phantom. d) For position(s) greater then 0mm separation the EUT was positioned as per the touch-safe position, and then the vertical height was decreased/adjusted as required. e) SAR measurements were evaluated at maximum power and the unit was operated for an appropriate period prior to the evaluation in order to minimise the drift. f) The device was keyed to operate continuously in the transmit mode for the duration of the test. g) The location of the maximum spatial SAR distribution (hot spot) was determined relative to the EUT and its antenna. h) The EUT was transmitting at full power throughout the duration of the test powered by a fully charged battery. Page: 12 of 169 RFI Global Services Ltd.

13 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Summary of Test Results Test Name Specification Reference Result Specific Absorption Rate-UMTS-FDD V Head OET Bulletin 65 Supplement C: Configuration 1g ( ) Complied Specific Absorption Rate-UMTS-FDD V Body OET Bulletin 65 Supplement C: Configuration 1g ( ) Complied Specific Absorption Rate-UMTS-FDD V + OET Bulletin 65 Supplement C: HSDPA Body Configuration 1g ( ) Complied Specific Absorption Rate-PCS 1900 Head OET Bulletin 65 Supplement C: Configuration 1g ( ) Complied Specific Absorption Rate-GPRS 1900 Body OET Bulletin 65 Supplement C: Configuration 1g ( ) Complied Specific Absorption Rate-PCS 1900 Body OET Bulletin 65 Supplement C: Configuration 1g ( ) Complied Specific Absorption Rate-Wi-Fi b/g/n OET Bulletin 65 Supplement C: Body Configuration 1g ( ) Complied SAR Individual Transmitter Evaluation device, mode Frequency, (MHz) P x (mw) P REF (mw) single SAR, W/kg Remarks WWAN, UMTS WWAN, GSM WLAN, WiFi802.11b/g/n FDD V Routine Evaluation Routine Evaluation Routine Evaluation BT, Bluetooth 2410 ~ 2 12 :=0 {P BT 2P REF } {d WWAN, BT > 5cm} SAR Simultaneous Transmitter Evaluation (x,y) D(x,y) cm L(x,y) cm SPLSR xy Sim-Tx SAR Remarks (WWAN GSM, BT) >5 n/a n/a n/a {no stand-alone SAR for BT} (WWAN GSM, Wi-Fi) >5 n/a n/a n/a Note(s): {D(x,y) > 5 } & {Σ WWAN, WLAN < 1.6 W/kg} 1. Simultaneous transmission evaluation was not required as the output power for Bluetooth was < (60/f) and the Sum of all antenna < 1.6w/kg. 2. Bluetooth transmitter thresholds output power P Ref = 12 as listed in KDB Px: power level measured by RFI. 4. Single SAR value was measured by RFI. 5. The -to- distance and -to-user distance were provided by the customer Location of Tests All the measurements described in this report were performed at the premises of RFI Global Services Ltd, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG United Kingdom Page: 13 of 169 RFI Global Services Ltd.

14 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Measurements, Examinations and Derived Results 7.1. General Comments This section contains test results only. Measurement uncertainties are evaluated in accordance with current best practice. Our reported expanded uncertainties are based on standard uncertainties, which are multiplied by an appropriate coverage factor to provide a statistical confidence level of approximately 95%. Please refer to section 8 for details of measurement uncertainties. Page: 14 of 169 RFI Global Services Ltd.

15 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Test Results Specific Absorption Rate - UMTS-FDD V Head Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 23.7 to 23.7 Results: EUT Position Touch Slide Closed Retracted Touch Slide Closed Extended Touch Slide Open Retracted Touch Slide Open Extended Tilt Slide Closed Retracted Tilt Slide Closed Extended Tilt Slide Open Retracted Tilt Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Left , 2 Complied Left , 2 Complied Left , 2 Complied Left , 2 Complied Left , 2 Complied Left , 2 Complied Left , 2 Complied Left , 2 Complied Page: 15 of 169 RFI Global Services Ltd.

16 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Specific Absorption Rate - UMTS-FDD V Head Configuration 1g (Continued) EUT Position Touch Slide Closed Retracted Touch Slide Closed Extended Touch Slide Open Retracted Touch Slide Open Extended Tilt Slide Closed Retracted Tilt Slide Closed Extended Tilt Slide Open Retracted Tilt Slide Open Extended Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Right , 2 Complied Right , 2 Complied Right , 2 Complied Right , 2 Complied Right , 2 Complied Right , 2 Complied Right , 2 Complied Right , 2 Complied 1. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC kbps RMC with TPC bits configured to all "1's". Page: 16 of 169 RFI Global Services Ltd.

17 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - UMTS-FDD V Body Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 21.2 to 21.2 Results: EUT Position Front of EUT Facing Phantom with Slide Closed Retracted Front of EUT Facing Phantom with Slide Closed Extended Front of EUT Facing Phantom with Slide Open Retracted Front of EUT Facing Phantom with Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Page: 17 of 169 RFI Global Services Ltd.

18 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Specific Absorption Rate - UMTS-FDD V Body Configuration 1g (Continued) EUT Position Rear of EUT Facing Phantom with Slide Closed Retracted Rear of EUT Facing Phantom with Slide Closed Extended Rear of EUT Facing Phantom with Slide Open Retracted Rear of EUT Facing Phantom with Slide Open Extended Rear of EUT Facing Phantom with Slide Closed Retracted with PHF Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied 1. SAR measurements were performed with the EUT at a separation distance of 15mm from the 'SAM' phantom flat section. 2. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC kbps RMC with TPC bits configured to all "1's". Page: 18 of 169 RFI Global Services Ltd.

19 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - UMTS-FDD V + HSDPA Body Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 21.2 to 21.2 Results: EUT Position Rear of EUT Facing Phantom with Slide Closed Retracted Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2, 3 Complied 1. SAR measurements were performed with the EUT at a separation distance of 15mm from the 'SAM' phantom flat section. 2. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC RMC+ HSDPA Enabled using FRC with H-Set 1, Test loop mode 1 and TPC bits configured to all "1's", Sub-test 1. Page: 19 of 169 RFI Global Services Ltd.

20 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - PCS 1900 Head Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 23.5 to 23.5 Results: EUT Position Touch Slide Closed Retracted Touch Slide Closed Extended Touch Slide Open Retracted Touch Slide Open Extended Tilt Slide Closed Retracted Tilt Slide Closed Extended Tilt Slide Open Retracted Tilt Slide Open Extended Tilt Slide Open Extended Tilt Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Left Complied Left Complied Left Complied Left Complied Left Complied Left Complied Left Complied Left Complied Left Complied Left Complied Page: 20 of 169 RFI Global Services Ltd.

21 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Specific Absorption Rate - PCS 1900 Head Configuration 1g (Continued) EUT Position Touch Slide Closed Retracted Touch Slide Closed Extended Touch Slide Open Retracted Touch Slide Open Extended Tilt Slide Closed Retracted Tilt Slide Closed Extended Tilt Slide Open Retracted Tilt Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Right Complied Right Complied Right Complied Right Complied Right Complied Right Complied Right Complied Right Complied Page: 21 of 169 RFI Global Services Ltd.

22 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - GPRS 1900 Body Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 23.2 to 23.2 Results: EUT Position Front of EUT Facing Phantom with Slide Closed Retracted Front of EUT Facing Phantom with Slide Closed Extended Front of EUT Facing Phantom with Slide Open Retracted Front of EUT Facing Phantom with Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Page: 22 of 169 RFI Global Services Ltd.

23 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Specific Absorption Rate - GPRS 1900 Body Configuration 1g (Continued) EUT Position Rear of EUT Facing Phantom with Slide Closed Retracted Rear of EUT Facing Phantom with Slide Closed Extended Rear of EUT Facing Phantom with Slide Open Retracted Rear of EUT Facing Phantom with Slide Open Extended Front of EUT Facing Phantom with Slide Open Extended With PHF Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied Flat (SAM) , 2 Complied 1. SAR measurements were performed with the EUT at a separation distance of 15mm from the 'SAM' phantom flat section. 2. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC-2. * GPRS mode configured with 2 Uplink slot active. Page: 23 of 169 RFI Global Services Ltd.

24 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - PCS 1900 Body Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 23.2 to 23.2 Results: EUT Position Front of EUT Facing Phantom with Slide Open Extended Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2 Complied 1. SAR measurements were performed with the EUT at a separation distance of 15mm from the 'SAM' phantom flat section. 2. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC-2. Page: 24 of 169 RFI Global Services Ltd.

25 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate - WLAN b/g/n Body Configuration 1g Test Summary: Tissue Volume: 1g Maximum Level (W/kg): Environmental Conditions: Temperature Variation in Lab ( C): 23.0 to 23.0 Temperature Variation in Liquid ( C): 21.9 to 21.9 Results: EUT Position Front of EUT Facing Phantom with Slide Closed Retracted Front of EUT Facing Phantom with Slide Closed Extended Front of EUT Facing Phantom with Slide Open Retracted Front of EUT Facing Phantom with Slide Open Extended Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Page: 25 of 169 RFI Global Services Ltd.

26 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Specific Absorption Rate WLAN b/g/n Body Configuration 1g (Continued) EUT Position Rear of EUT Facing Phantom with Slide Closed Retracted Rear of EUT Facing Phantom with Slide Closed Extended Rear of EUT Facing Phantom with Slide Open Retracted Rear of EUT Facing Phantom with Slide Open Extended Rear of EUT Facing Phantom with Slide Closed Retracted With PHF Rear of EUT Facing Phantom with Slide Closed Retracted Rear of EUT Facing Phantom with Slide Closed Retracted Note(s): Phantom Configuration Channel Number Level (W/kg) Limit (W/kg) Margin (W/kg) Note(s) Result Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 3 Complied Flat (SAM) , 2, 4 Complied Flat (SAM) , 2, 5 Complied 1. SAR measurements were performed with the EUT at a separation distance of 15mm from the 'SAM' phantom flat section. 2. SAR test was performed in the middle channel only as the measured levels were < 50% of the SAR limit as stated in the FCC Public Notice DA by the SCC-34/SC WLAN b at 1 Mbps 4. WLAN g at 6 Mbps 5. WLAN n at 6.5 Mbps Page: 26 of 169 RFI Global Services Ltd.

27 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Conducted Average Power Measurement UMTS FDD V Modes HSDPA WCDMA Voice / Sets RMC12.2kbps Band Channel Power (dbm) Avg. Power (dbm) Avg. Power (dbm) Avg. Power (dbm) Avg. Power (dbm) Avg ßc ßd ACK, NACK, CQI Sub-test 1 Setup for Release 5 HSDPA Sub-test β c β d Β d (SF) β c/ β d β hs (1) SM (db) (2) 1 2/15 15/ /15 4/ /15 (3) 15/15 (3) 64 12/15 (3) 24/ /15 8/ /8 30/ /15 4/ /4 30/ Note 1: Δ ACK, Δ NACK and Δ CQI = 8 A hs = β hs/β c = 30/15 β hs = 30/15 * β c Note 2: CM = 1 for β c/ β d = 12/15, Β hs/β c = 24/15 Note 3: For subtest 2 the β c/ β d ratio of 12/15 for the TFC during the measurement period (TF1, TF0) is achieved by setting the signalled gain factors for the reference TFC (TF1, TF1) to β c = 11/15 and β d = 15/15 PCS/GPRS 1900 Average Power Measurements Channel Number Frequency (MHZ) GSM TX Power before Test (dbm) GPRS TX Power before Test (dbm) Note Conducted Conducted Conducted Page: 27 of 169 RFI Global Services Ltd.

28 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Conducted Average Power Measurement (Continued) WLAN b/g/n Channel Number Frequency (GHZ) TX Power before Test (dbm) Note 2.4GHz b (1Mbps) 2.4GHz b (11Mbps) 2.4GHz g (6Mbps) 2.4GHz g (54Mbps) 2.4GHz n (6.5Mbps) 2.4GHz n (65Mbps) Page: 28 of 169 RFI Global Services Ltd.

29 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Measurement Uncertainty No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the results. Consequently, the result of a measurement is only an approximation to the value of the measurand (the specific quantity subject to measurement) and is only complete when accompanied by a statement of the uncertainty of the approximation. The expression of uncertainty of a measurement result allows realistic comparison of results with reference values and limits given in specifications and standards. The uncertainty of the result may need to be taken into account when interpreting the measurement results. The reported expanded uncertainties below are based on a standard uncertainty multiplied by an appropriate coverage factor, such that a confidence level of approximately 95% is maintained. For the purposes of this document approximately is interpreted as meaning effectively or for most practical purposes. Test Name Confidence Level Calculated Uncertainty Specific Absorption Rate-UMTS-FDD V Head Configuration 1g 95% Specific Absorption Rate-UMTS-FDD V Body Configuration 1g 95% Specific Absorption Rate-PCS 1900 Head Configuration 1g 95% Specific Absorption Rate-GPRS/PCS 1900 Body Configuration 1g 95% Specific Absorption Rate-Wi-Fi 2450 Body Configuration 1g 95% The methods used to calculate the above uncertainties are in line with those recommended within the various measurement specifications. Where measurement specifications do not include guidelines for the evaluation of measurement uncertainty, the published guidance of the appropriate accreditation body is followed. Page: 29 of 169 RFI Global Services Ltd.

30 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate Uncertainty - UMTS FDD V Head Configuration 1g Standard υ + - Probability i Type Source of uncertainty Value Value Distribution Divisor ci Uncertainty (10g) or + u (%) - u (%) υ eff B Probe calibration normal (k=2) B Axial Isotropy normal (k=2) B Hemispherical Isotropy normal (k=2) B Spatial Resolution Rectangular B Boundary Effect Rectangular B Linearity Rectangular B Detection Limits Rectangular B Readout Electronics normal (k=2) B Response Time Rectangular B Integration Time Rectangular B RF Ambient conditions Rectangular B B B Probe Positioner Mechanical Restrictions Probe Positioning with regard to Phantom Shell Extrapolation and integration / Maximum SAR evaluation Rectangular Rectangular Rectangular A Test Sample Positioning normal (k=1) A Device Holder uncertainty normal (k=1) B Phantom Uncertainty Rectangular B Drift of output power Rectangular B Liquid Conductivity (target value) Rectangular A Liquid Conductivity (measured value) normal (k=1) B Liquid Permittivity (target value) Rectangular A Liquid Permittivity (measured value) normal (k=1) Combined standard uncertainty t-distribution >200 Expanded uncertainty k = >200 Page: 30 of 169 RFI Global Services Ltd.

31 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate- UMTS FDD V Body Configuration 1g Standard υ + - Probability i Type Source of uncertainty Value Value Distribution Divisor ci Uncertainty (10g) or + u (%) - u (%) υ eff B Probe calibration normal (k=2) B Axial Isotropy normal (k=2) B Hemispherical Isotropy normal (k=2) B Spatial Resolution Rectangular B Boundary Effect Rectangular B Linearity Rectangular B Detection Limits Rectangular B Readout Electronics normal (k=2) B Response Time Rectangular B Integration Time Rectangular B RF Ambient conditions Rectangular B B B Probe Positioner Mechanical Restrictions Probe Positioning with regard to Phantom Shell Extrapolation and integration /Maximum SAR evaluation Rectangular Rectangular Rectangular A Test Sample Positioning normal (k=1) A Device Holder uncertainty normal (k=1) B Phantom Uncertainty Rectangular B Drift of output power Rectangular B Liquid Conductivity (target value) Rectangular A Liquid Conductivity (measured value) normal (k=1) B Liquid Permittivity (target value) Rectangular A Liquid Permittivity (measured value) normal (k=1) Combined standard uncertainty t-distribution >250 Expanded uncertainty k = >250 Page: 31 of 169 RFI Global Services Ltd.

32 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate-PCS 1900 Head Configuration 1g Standard υ + - Probability i Type Source of uncertainty Value Value Distribution Divisor ci Uncertainty (10g) or + u (%) - u (%) υ eff B Probe calibration normal (k=2) B Axial Isotropy normal (k=2) B Hemispherical Isotropy normal (k=2) B Spatial Resolution Rectangular B Boundary Effect Rectangular B Linearity Rectangular B Detection Limits Rectangular B Readout Electronics normal (k=2) B Response Time Rectangular B Integration Time Rectangular B RF Ambient conditions Rectangular B B B Probe Positioner Mechanical Restrictions Probe Positioning with Regard to Phantom Shell Extrapolation and integration / Maximum SAR evaluation Rectangular Rectangular Rectangular A Test Sample Positioning normal (k=1) A Device Holder uncertainty normal (k=1) B Phantom Uncertainty Rectangular B Drift of output power Rectangular B Liquid Conductivity (target value) Rectangular A Liquid Conductivity (measured value) normal (k=1) B Liquid Permittivity (target value) Rectangular A Liquid Permittivity (measured value) normal (k=1) Combined standard uncertainty t-distribution >200 Expanded uncertainty k = >200 Page: 32 of 169 RFI Global Services Ltd.

33 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate-PCS / GPRS1900 Body Configuration 1g Standard υ + - Probability i Type Source of uncertainty Value Value Distribution Divisor ci Uncertainty (10g) or + u (%) - u (%) υ eff B Probe calibration normal (k=2) B Axial Isotropy normal (k=2) B Hemispherical Isotropy normal (k=2) B Spatial Resolution Rectangular B Boundary Effect Rectangular B Linearity Rectangular B Detection Limits Rectangular B Readout Electronics normal (k=2) B Response Time Rectangular B Integration Time Rectangular B RF Ambient conditions Rectangular B B B Probe Positioner Mechanical Restrictions Probe Positioning with regard to Phantom Shell Extrapolation and integration / Maximum SAR evaluation Rectangular Rectangular Rectangular A Test Sample Positioning normal (k=1) A Device Holder uncertainty normal (k=1) B Phantom Uncertainty Rectangular B Drift of output power Rectangular B Liquid Conductivity (target value) Rectangular A Liquid Conductivity (measured value) normal (k=1) B Liquid Permittivity (target value) Rectangular A Liquid Permittivity (measured value) normal (k=1) Combined standard uncertainty t-distribution >200 Expanded uncertainty k = >200 Page: 33 of 169 RFI Global Services Ltd.

34 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March Specific Absorption Rate-Wi-Fi 2450 Body Configuration 1g Standard υ + - Probability i Type Source of uncertainty Value Value Distribution Divisor ci Uncertainty (10g) or + u (%) - u (%) υ eff B Probe calibration normal (k=2) B Axial Isotropy normal (k=2) B Hemispherical Isotropy normal (k=2) B Spatial Resolution Rectangular B Boundary Effect Rectangular B Linearity Rectangular B Detection Limits Rectangular B Readout Electronics normal (k=2) B Response Time Rectangular B Integration Time Rectangular B RF Ambient conditions Rectangular B B B Probe Positioner Mechanical Restrictions Probe Positioning with regard to Phantom Shell Extrapolation and integration / Maximum SAR evaluation Rectangular Rectangular Rectangular A Test Sample Positioning normal (k=1) A Device Holder uncertainty normal (k=1) B Phantom Uncertainty Rectangular B Drift of output power Rectangular B Liquid Conductivity (target value) Rectangular A Liquid Conductivity (measured value) normal (k=1) B Liquid Permittivity (target value) Rectangular A Liquid Permittivity (measured value) normal (k=1) Combined standard uncertainty t-distribution >200 Expanded uncertainty k = >200 Page: 34 of 169 RFI Global Services Ltd.

35 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Appendix 1. Test Equipment Used RFI No. Instrument Manufacturer Type No. Serial No. A034 A1097 Narda 20W Termination SMA Directional Coupler Narda 374BNM 8706 MiDISCO MDC None A1137 3dB Attenuator Narda A1174 A1328 A1182 Dielectric Probe Kit Handset Positioner Handset Positioner Agilent Technologies Schmid & Partner Engineering AG Schmid & Partner Engineering AG 85070C Modification Us SD 000 H01 DA Date Last Calibrated Calibrated as part of system Calibrated as part of system Calibrated as part of system Calibrated before use - - V3.0 None - - Cal. Interval (Months) A1234 Data Acquisition Electronics Schmid & Partner Engineering AG DAE Feb A MHz Dipole Kit Schmid & Partner Engineering AG D900V Feb A MHz Dipole Kit Schmid & Partner Engineering AG D1900V Feb A1238 SAM Phantom Schmid & Partner Engineering AG SAM b 001 Calibrated before use - A MHz Dipole Kit Schmid & Partner Engineering AG D2450V Feb A1378 Probe Schmid & Partner Engineering AG EX3 DV Feb A1497 Amplifier Mini-Circuits zhl-42w (sma) e Calibrated as part of system - A1566 SAM Phantom Schmid & Partner Engineering AG A1990 Digital Camera Samsung E515 SAM a 002 A db Attenuator Narda A23WC90 8A05431K Calibrated before use - - Calibrated as part of system A1531 AARONIA AG C1042 C1145 C1146 Network Analyzer Cable Agilent Cable Cable Rosenberger MICRO- COAX Rosenberger MICRO-COAX FA147A F FA147A F Calibrated as part of system Calibrated as part of system Page: 35 of 169 RFI Global Services Ltd.

36 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 RFI No. Instrument Manufacturer Type No. Serial No. Date Last Calibrated Cal. Interval (Months) G0528 Robot Power Supply Schmid & Partner Engineering AG DASY4 None Calibrated before use - G087 PSU Thurlby Thandar CPX Calibrated before use - M1015 Network Analyser Agilent Technologies 8753ES US Sept M1047 Robot Arm Staubli RX908 L F00/SD8 9A1/A/01 Calibrated before use - M1159 Signal Generator Agilent Technologies E8241A US Internal Checked 15 Dec M1071 Spectrum Analyzer Agilent HP8590E 3647U00514 (Monitoring use only) - M1270 Temperature/ Humidity/ Pressure Meter RS Components None None Internal Checked 31 March M1071 Spectrum Analyzer Agilent HP8590E 3647U00514 (Monitoring use only) - M1044 M265 M263 Diode Power Sensor Diode Power Sensor Dual Channel Power Meter Rohde & Schwarz NRV-Z / May Rohde & Schwarz NRV-Z / May Rohde & Schwarz NRVD / May S256 SAR Lab RFI Site 56 N/A Calibrated before use - Page: 36 of 169 RFI Global Services Ltd.

37 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 A.1.1. Calibration Certificates This section contains the calibration certificates and data for the Probe(s) and Dipole(s) used, which are not included in the total number of pages for this report. Page: 37 of 169 RFI Global Services Ltd.

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 Appendix 2. Measurement Methods A.2.1. Evaluation Procedure The Specific Absorption Rate (SAR) evaluation was performed in the following manner: a) (i) The evaluation was performed in an applicable area of the phantom depending on the type of device being tested. For devices worn about the ear during normal operation, both the left and right ear positions were evaluated at the centre frequency of the band at maximum power. The side, which produced the greatest SAR, determined which side of the phantom would be used for the entire evaluation. The positioning of the head worn device relative to the phantom was dictated by the test specification identified in section 3.1 of this report. (ii) For body worn devices or devices which can be operated within 20 cm of the body, the flat section of the SAM phantom was used were the size of the device(s) is normal. for bigger devices and base station the 2mm Oval phantom is used for evaluation. The type of device being evaluated dictated the distance of the EUT to the outer surface of the phantom flat section. b) The SAR was determined by a pre-defined procedure within the DASY4 software. The exposed region of the phantom was scanned near the inner surface with a grid spacing of 20mm x 20mm or appropriate resolution. c) A 5x5x7 matrix was performed around the greatest spatial SAR distribution found during the area scan of the applicable exposed region. SAR values were then calculated using a 3-D spline interpolation algorithm and averaged over spatial volumes of 1 and 10 grams. d) If the EUT had any appreciable drift over the course of the evaluation, then the EUT was reevaluated. Any unusual anomalies over the course of the test also warranted a re-evaluation. Page: 38 of 169 RFI Global Services Ltd.

77 Test Report Serial No: RFI/SAR/RP81001JD16A V3.0 Version 3.0 Issue Date: 24 March 2011 A.2.2. Specific Absorption Rate (SAR) Measurements to OET Bulletin 65 Supplement C: ( ) Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields SAR measurements were performed in accordance with Appendix D of the standard FCC OET Bulletin 65 Supplement C: 2001, IEEE 1528 and FCC KDB procedures, against appropriate limits for each measurement position in accordance with the standard. In some cases the FCC was contacted using a PBA or KDB process to ensure test is performed correctly. The test was performed in a shielded enclosure with the temperature controlled to remain between +18.0ºC and +25.0ºC. The tissue equivalent material fluid temperature was controlled to give a maximum variation of ± 2.0ºC Prior to any SAR measurements on the EUT, system validation and material dielectric property measurements were conducted. In the absence of a detailed procedure within the specification, system validation and material dielectric property measurements were performed in accordance with Appendix C and Appendix D of FCC OET Bulletin 65 Supplement C: 2001 and FCC KDB publication Following the successful system validation and material dielectric property measurements, a SAR versus time sweep shall be performed within 10 mm of the phantom inner surface. If the EUT power output is stable after three minutes then the measurement probe will perform a coarse surface level scan at each test position in order to ascertain the location of the maximum local SAR level. Once this area had been established, a 5x5x7 cube of 343 points (5 mm spacing in each axis 27g) will be centred at the area of concern. Extrapolation and interpolation will then be carried out on the 27g of tissue and the highest averaged SAR over a 10g cube determined. Once the maximum interpolated SAR measurement is complete; the coarse scan is visually assessed to check for secondary peaks within 50% of the maximum SAR level. If there are any further SAR measurements required, extra 5x5x7 cubes shall be centred on each of these extra local SAR maxima. At the end of each position test case a second time sweep shall be performed to check whether the EUT has remained stable throughout the test. Page: 39 of 169 RFI Global Services Ltd.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Serial No: RFI/SAR2/RP74716JD10A Supersedes Serial No: RFI/SAR1/RP74716JD10A This Is Issued Under The Authority Of Stuart Thomas, General Manager Cellular Services:

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Connexion2 Ltd, Identicom t777 To: OET Bulletin 65 Supplement C: (2001-01) RSS-102 Issue 4 March 2010 Test Report Serial No: RFI-SAR-RP81383JD01A V4.0

More information

This report cancels and replaces the test report R052-DAS /A Ed. 0 SAR TEST REPORT. According to the standard: EN : 2006

This report cancels and replaces the test report R052-DAS /A Ed. 0 SAR TEST REPORT. According to the standard: EN : 2006 R052-DAS-12-104374-3/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-3/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Serial No: RFI/SARE1/RP72887JD01A This Is Issued Under The Authority Of Steve Flooks, Service Leader Radio Performance Group: Checked By: Joe Lomako Report Copy

More information

SAR TEST REPORT. According to the standard: EN : 2006

SAR TEST REPORT. According to the standard: EN : 2006 RE052-12-106218-1/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch for mobile phone FAZUP Tested with an Apple iphone 5 (A1429) Company: - DISTRIBUTION:

More information

SAR TEST REPORT. According to the standard: EN : Equipment under test: Horizontal case for Smartphone Duthilleul Process

SAR TEST REPORT. According to the standard: EN : Equipment under test: Horizontal case for Smartphone Duthilleul Process SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Horizontal case for Smartphone Duthilleul Process Tested with a SAMSUNG Galaxy S4 (GT-I9505) Company: Mr. DUTHILLEUL DISTRIBUTION:

More information

SAR TEST REPORT. According to the standard: EN : 2006 Fast measurements. Company: FAZUP

SAR TEST REPORT. According to the standard: EN : 2006 Fast measurements. Company: FAZUP SAR TEST REPORT According to the standard: EN 62209-1: 2006 Fast measurements Equipment under test: Antenna patch for mobile phone FAZUP Tested with a SAMSUNG Galaxy S4 (GT-I9505) Company: FAZUP DISTRIBUTION:

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: Smart Gears Limited, Micro-tracker MT-01 To: 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP81827JD05A This test report is issued under

More information

SAR Test Report. Report Number: M170410F

SAR Test Report. Report Number: M170410F Report No. M170410F FCC ID: W77G7X ISED ID: 8255A-G7X Page 1 of 79 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: CIBS To: FCC Part 15.247: 2008 Subpart C, RSS-210 Issue 7 June 2007 & RSS-Gen Issue 2 June 2007 Test Report Serial No: RFI/RPT2/RP75103JD05A Supersedes Test Report

More information

SAR Compliance Test Report

SAR Compliance Test Report SAR Compliance Test Report Test report no.: Date of report: 2007-08-23 Template version: 6.0 Number of pages: 62 Testing laboratory: TCC Nokia Salo Laboratory P.O.Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101

More information

SAR TEST REPORT. Test Report No. : H

SAR TEST REPORT. Test Report No. : H SAR TEST REPORT Test Report No. : 10935242H Test report No. : 10935242H Page : 1 of 140 Applicant : Intel Mobile Communications Type of Equipment : and BT module installed on 2in1 PC PDW0J Model No. :

More information

RESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA

RESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA RESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA DEPARTMENT LABORATORIES High Voltage Division - HVD Laboratory for SAR evaluation Bvd. Decebal No. 118,

More information

SAR Test Report. Report Number: M Evaluation of the SAR of Apple iphones When Fitted with the Brainwave Patchd

SAR Test Report. Report Number: M Evaluation of the SAR of Apple iphones When Fitted with the Brainwave Patchd Page 1 of 103 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: melb@emctech.com.au SAR Test Report Report

More information

SAR Evaluation Considerations for Handsets with Multiple Transmitters and Antennas

SAR Evaluation Considerations for Handsets with Multiple Transmitters and Antennas Evaluation Considerations for Handsets with Multiple Transmitters and Antennas February 2008 Laboratory Division Office of Engineering and Techlogy Federal Communications Commission Introduction This document

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Ingenico France, IWL252-01T1535A To: 47CFR15.107, 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP82173JD02A V2.0 Version

More information

FCC SAR Test Report. : Motorola Mobility, LLC. : Mobile Cellular Phone. STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE

FCC SAR Test Report. : Motorola Mobility, LLC. : Mobile Cellular Phone. STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE Exhibit 11 Report No. : FA451423B FCC SAR Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : 3605 FCC ID : Motorola Mobility LLC : Mobile Cellular Phone : Motorola Mobility, LLC : IHDT56QA2 STANDARD

More information

Shenzhen Academy of Information and Communications Technology SAR TEST REPORT. No. B17N01624-SAR. For. Roam Data Inc. POS Tablet. Model Name: Moby/M70

Shenzhen Academy of Information and Communications Technology SAR TEST REPORT. No. B17N01624-SAR. For. Roam Data Inc. POS Tablet. Model Name: Moby/M70 Shenzhen Academy of Information and Communications Technology SAR TEST REPORT For Roam Data Inc. POS Tablet Model Name: Moby/M70 With Hardware Version: 9888C Software Version: M70 FCC: 2ABY6-M70 Issued

More information

11 MEASUREMENT PROCEDURES

11 MEASUREMENT PROCEDURES 11 MEASUREMENT PROCEDURES 11.1 GENERAL DESCRIPTION OF TEST PROCEDURES For WLAN SAR testing, WLAN engineering testing software installed on the EUT can provide continuous transmitting RF signal. This RF

More information

SAR Test Report. Report Number: M Evaluation of the SAR of IPhone 6 series when fitted with the Cellsafe Radi

SAR Test Report. Report Number: M Evaluation of the SAR of IPhone 6 series when fitted with the Cellsafe Radi Page 1 of 74 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: melb@emctech.com.au SAR Test Report Report

More information

SAR Test Report. Report Number: M Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Brainwave Smart Chip

SAR Test Report. Report Number: M Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Brainwave Smart Chip Page 1 of 88 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: melb@emctech.com.au SAR Test Report Report

More information

TEST REPORT. In the configuration tested, the EUT complied with the standards specified above. Remarks:

TEST REPORT. In the configuration tested, the EUT complied with the standards specified above. Remarks: Page : 1 of 38 TEST REPORT Equipment Under Test : CB54G2 Model No. : MS-6835 FCC ID : I4L-MS6835 Applicant : MICRO-STAR INT L CO., LTD. Address of Applicant : 3F-5 No. 30, Tai-Yuan St, Zhu-Bei City, Hsinchu

More information

Report Number: M140907_R1 (Replacing M140907) Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Cellsafe Smart Chip

Report Number: M140907_R1 (Replacing M140907) Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Cellsafe Smart Chip Page 1 of 88 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: sales@emctech.com.au SAR Test Report Report

More information

SAR Compliance Test Report

SAR Compliance Test Report SAR Compliance Test Report Test report no.: Date of report: 2009-10-22 Template version: 12.0 Number of pages: 25 Testing laboratory: TCC Nokia Salo Laboratory P.O.Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: C-Track NX55 To: EN 300 440-1 V1.6.1 (2010-08) in accordance with EN 300 440-2 V1.4.1 (2010-08) Test Report Serial No.: RFI-RPT-RP84347JD02A This Test Report Is Issued

More information

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B

More information

No. I18Z60328-SEM01 Page 43 of Simultaneous TX SAR Considerations Introduction Transmit Antenna Separation Distances

No. I18Z60328-SEM01 Page 43 of Simultaneous TX SAR Considerations Introduction Transmit Antenna Separation Distances Page 43 of 208 12 Simultaneous TX SAR Considerations 12.1 Introduction The following procedures adopted from FCC SAR Considerations for Cell Phones with Multiple Transmitters are applicable to handsets

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: Maestro Wireless Solutions Limited, Maestro 100evo To: EN 301 489-1 V1.8.1 referencing EN 301 489-7 V1.3.1 Test Report Serial No: RFI-EMC-RP78797JD02A This test report

More information

SAR TEST REPORT KIDS GPS WATCH. wonlex GW400S. Front of face: W/kg. Wrist: W/kg

SAR TEST REPORT KIDS GPS WATCH. wonlex GW400S. Front of face: W/kg. Wrist: W/kg S T S SAR TEST REPORT Report No: STS1801246H01 Issued for Shenzhen Wonlex Technology Co., Ltd. 7-8 Floor, BLK B, GangHuaXing Fifth Industrial Park, No.118 YongFu Rd, QiaoTou Area, BaoAn District, Shenzhen,

More information

Prepared for APPLE INC.. Prepared by

Prepared for APPLE INC.. Prepared by FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE STD 1528:2003 SAR SUPPLEMETAL EVALUATION REPORT For iphone / RoW SKU MODEL: A13877 IC: 579C-E2430A REPORT NUMBER: 11U13896-5ARoW ISSUE DATE: OCT. 01, 2011 Prepared

More information

SAR Test Report. Report Number: M080928

SAR Test Report. Report Number: M080928 Page 1 of 52 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: melb@emctech.com.au SAR Test Report Report

More information

SAR EVALUATION REPORT. FCC 47 CFR IEEE Std For GSM/WCDMA Phone + Bluetooth & WLAN 2.4GHz b/g/n

SAR EVALUATION REPORT. FCC 47 CFR IEEE Std For GSM/WCDMA Phone + Bluetooth & WLAN 2.4GHz b/g/n SAR EVALUATION REPORT FCC 47 CFR 2.1093 IEEE Std 128-2013 For GSM/WCDMA Phone + Bluetooth & WLAN 2.4GHz b/g/n FCC ID: A3LSMG31H Model Name: SM-G31H/DS and SM-G31H Report Number: 1K20806-S1 Issue Date:

More information

Portable Cellular Phone SAR Test Report

Portable Cellular Phone SAR Test Report MOTOROLA, INC. Portable Cellular Phone SAR Test Report Number: 24078-1 FCC ID: IHDP56LM1 Portable Cellular Phone SAR Test Report Tests Requested By: Motorola Mobility, Inc. 600 N. US Highway 45 Libertyville,

More information

SAR Compliance Test Report

SAR Compliance Test Report Nokia SAR Compliance Test Report Test report no.: Template version: 13.0 TCC Nokia Salo Laboratory P.O.Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180

More information

Report Number: M151240_R2 (Replacing M151240_R1) Evaluation of the SAR of Samsung Galaxy S6 when fitted with the Cellsafe Wide

Report Number: M151240_R2 (Replacing M151240_R1) Evaluation of the SAR of Samsung Galaxy S6 when fitted with the Cellsafe Wide Page 1 of 69 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: sales@emctech.com.au SAR Test Report Report

More information

SAR TEST REPORT. No. I16Z40969-SEM01. For

SAR TEST REPORT. No. I16Z40969-SEM01. For SAR TEST REPORT No. I16Z40969-SEM01 For TCL Communication Ltd. GSM/WCDMA/LTE mobile phone Model name: 4060O With Hardware Version: 02 Software Version: A3RUCR0 FCC ID: 2ACCJB039 Issued Date: 2016-6-3 Note:

More information

Test Report. Test Report Identifier: SC b. Tested Device: Bluetooth USB Dongle - m2m Blue According to the standards: IEEE

Test Report. Test Report Identifier: SC b. Tested Device: Bluetooth USB Dongle - m2m Blue According to the standards: IEEE Test Report Test Report Identifier: SC-0901-305-02b Tested Device: Bluetooth USB Dongle - According to the standards: IEEE1528-2003 Recommended Practice for Determining the Peak Spatial-Average SAR from

More information

SPORTON INTERNATIONAL (XI AN) INC.

SPORTON INTERNATIONAL (XI AN) INC. FCC SAR Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID : ZTE CORPORATION : / Multi-mode Digital Mobile Phone : ZTE : Z835, Z851 : SRQ-Z835 STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE

More information

SAR TEST REPORT. No. I18Z60067-SEM03. For. Vodafone. GSM UMTS LTE mobile phone. Model Name: VFD 720. With. Hardware Version: PIO 02

SAR TEST REPORT. No. I18Z60067-SEM03. For. Vodafone. GSM UMTS LTE mobile phone. Model Name: VFD 720. With. Hardware Version: PIO 02 SAR TEST REPORT No. I18Z60067-SEM03 For Vodafone GSM UMTS LTE mobile phone Model Name: VFD 720 With Hardware Version: PIO 02 Software Version: 3E22 FCC ID: 2ACCJH081 Issued Date: 2018-3-16 Note: The test

More information

SAR EVALUATION REPORT. Samsung Electronics, Co. Ltd. 07/28/14-08/08/14 129, Samsung-ro, Maetan dong, Test Site/Location: SM-N910G

SAR EVALUATION REPORT. Samsung Electronics, Co. Ltd. 07/28/14-08/08/14 129, Samsung-ro, Maetan dong, Test Site/Location: SM-N910G PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctestlab.com Applicant Name: Date of Testing: Samsung Electronics,

More information

RF EXPOSURE EVALUATION SPECIFIC ABSORPTION RATE SAR TEST REPORT

RF EXPOSURE EVALUATION SPECIFIC ABSORPTION RATE SAR TEST REPORT Test Report Serial No.: 013006QWL-T716-S24C Report Issue No.: S716C-030106-R0 Dates of Evaluation: February 02-03, 2006 Report Issue Date: March 01, 2006 Type of Evaluation: RF Exposure SAR FCC 47 CFR

More information

Function Entrust TEST REPORT

Function Entrust TEST REPORT Function Entrust TEST REPORT of Anti-radiation Cellphone Cover & Skin T r a d e Name: PMA Brand Name.: PMA prepared for Anhui PMA Investment Co.,Ltd PMA Mansion, NO.16 building, International E-commerce

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBL SERVICES LTD Partial Test of: BTM4 To: FCC Part 5.247: 08 Subpart C, RSS- Issue 7 June 07 & RSS-Gen Issue 2 June 07 Test Report Serial No: RFI/RPT/RP78JD03 This Test Report Is Issued Under

More information

Sporton International (Shenzhen) Inc.

Sporton International (Shenzhen) Inc. FCC SAR Test Report APPLICANT EQUIPMENT BRAND NAME : Planet Avvio LLC : Mobile phone : Avvio MODEL NAME : 362 FCC ID : 2ALTA362X STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C95.1-1992 IEEE 1528-2013

More information

TEST REPORT. No. I17D00062-SAR01. For. Client: MobiWire SAS. Production: 3G Feature Phone. Model Name: MobiWire Sakari FCC ID: QPN-SAKARI

TEST REPORT. No. I17D00062-SAR01. For. Client: MobiWire SAS. Production: 3G Feature Phone. Model Name: MobiWire Sakari FCC ID: QPN-SAKARI TEST REPORT No. I17D00062-SAR01 For Client: MobiWire SAS Production: 3G Feature Phone Model Name: MobiWire Sakari FCC ID: QPN-SAKARI Hardware Version: V01 Software Version: Vodafone_Sakari_SKU3_L_V03_170509_MP

More information

SAR EVALUATION REPORT. FCC 47 CFR IEEE Std For Tablet Device. FCC ID: BCGA1701 Model Name: A1701

SAR EVALUATION REPORT. FCC 47 CFR IEEE Std For Tablet Device. FCC ID: BCGA1701 Model Name: A1701 SAR EVALUATION REPORT FCC 47 CFR 2.1093 IEEE Std 1528-2013 For Tablet Device FCC ID: BCGA1701 l Name: A1701 Report Number: 16U23817-S1V2 Issue Date: 3/6/2017 Prepared for APPLE, INC. 1 INFINITE LOOP, MS

More information

FCC OET BULLETIN 65 SUPPLEMENT C IEEE STD 1528:2003 RSS-102 Issue 4, March 2010 RSS-102 Supplementary Procedures (SPR)-001, January 1, 2011

FCC OET BULLETIN 65 SUPPLEMENT C IEEE STD 1528:2003 RSS-102 Issue 4, March 2010 RSS-102 Supplementary Procedures (SPR)-001, January 1, 2011 FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE STD 1528:2003 RSS-102 Issue 4, March 2010 RSS-102 Supplementary Procedures (SPR)-001, January 1, 2011 SAR EVALUATION REPORT For 802.11g WIRELESS LAN + BLUETOOTH

More information

SAR TEST REPORT. Test Report No.: S-A. Platform Platform type. model

SAR TEST REPORT. Test Report No.: S-A. Platform Platform type. model Page : 1 of 44 Revised date : December 15, 2016 (-r01) TEST REPORT Test Report No.: 11359370S-A Applicant : Canon Inc. Type of Equipment : Wireless Module Model No. : ES200 (*. It was installed into ES200's

More information

DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2

DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2 TESTING CERT # 2518.05 DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2 Motorola Solutions Inc. EME Test Laboratory Motorola Solutions Malaysia Sdn Bhd (Innoplex) Plot 2A, Medan Bayan Lepas, Mukim

More information

FCC SAR EVALUATION REPORT

FCC SAR EVALUATION REPORT Page 1 of 106 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 Product Name: Medical Guardian FRG01000 Trademark:

More information

SAR TEST REPORT. No. I17Z60078-SEM03. TCL Communication Ltd. LTE / UMTS / GSM mobile phone. Model Name: VFD 610. With. Hardware Version:PIO

SAR TEST REPORT. No. I17Z60078-SEM03. TCL Communication Ltd. LTE / UMTS / GSM mobile phone. Model Name: VFD 610. With. Hardware Version:PIO SAR TEST REPORT No. I17Z60078-SEM03 For TCL Communication Ltd. LTE / UMTS / GSM mobile phone Model Name: VFD 610 With Hardware Version:PIO Software Version: v6kc5 FCC ID: 2ACCJH071 Issued Date:2017-4-12

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBL SERVICES LTD Partial Test of: Motorola Point to Point Fixed Wireless Solutions PTP58 5.8 GHz band Wireless Ethernet Bridge To: FCC Part 5.47: 8 Subpart C, RSS- Issue 7 June 7 & RSS-Gen Issue

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBL SERVICES LTD Partial Test of: 5 To: FCC Part 5.247: 2008 Subpart C Test Report Serial No: RFI/RPT/RP79JD03 This Test Report Is Issued Under The uthority Of Brian Watson, Operations Director:

More information

DIRECTORY SZ S02 1. TESTING LABORATORY... 4

DIRECTORY SZ S02 1. TESTING LABORATORY... 4 DIRECTORY 1. TESTING LABORATORY... 4 1.1. Identification of the Responsible Testing Location... 4 1.2. Accreditation Certificate... 4 1.3. List of Test Equipments... 4 2. TECHNICAL INFORMATION... 5 2.1.

More information

RF Exposure evaluation

RF Exposure evaluation Shenzhen Global Test Service Co.,Ltd. 1F, Building No. 13A, Zhonghaixin Science and Technology City, No.12,6 Road, Ganli Industrial Park, Buji Street, Longgang District, Shenzhen, Guangdong RF Exposure

More information

1F, Building A3, No. 39 Chuangye Rd., Xi'an Hi-tech Zone, Shanxi Province, P. R. China

1F, Building A3, No. 39 Chuangye Rd., Xi'an Hi-tech Zone, Shanxi Province, P. R. China FCC SAR Test Report APPLICANT : Lenovo Mobile Communication Technology Ltd. EQUIPMENT BRAND NAME MODEL NAME FCC ID : Lenovo Mobile Phone : Lenovo : Lenovo K10a40 : YCNK10A40 STANDARD : FCC 47 CFR Part

More information

Accredited testing laboratory

Accredited testing laboratory Huawei Base, Bantian, Longgang District, Shenzhen, P.R.China Phone: +86-755-28785278 SAR-Laboratory Fax: +86-755-36834474. Accredited testing laboratory CNAS Registration number: L0310 Report On SAR Test

More information

TEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017

TEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017 Test Report No. : UL-RPT-RP11327903JD02A V3.0 Manufacturer : Kontakt Micro-Location Sp. z o.o. Model No. : Kontakt Smart Beacon 2 FCC ID : 2ADAO-SB2-V250 Technology : Bluetooth Low Energy Test Standard(s)

More information

Appendix for the Report Dosimetric Assessment of the Portable Device Selex Elsag S.p.A. PUMA T3 plus (FCC ID: X5Y )

Appendix for the Report Dosimetric Assessment of the Portable Device Selex Elsag S.p.A. PUMA T3 plus (FCC ID: X5Y ) The Testcenter facility Dosimetric Test Lab within IMST GmbH is accredited by the German National Deutsche Akkreditierungsstelle GmbH (DAkkS) for testing according to the scope as listed in the accreditation

More information

SPORTON INTERNATIONAL (KUNSHAN) INC.

SPORTON INTERNATIONAL (KUNSHAN) INC. FCC SAR Test Report APPLICANT EQUIPMENT BRAND NAME : Doro AB : GSM/WCDMA/LTE Mobile Telephone : doro MODEL NAME : DSB-0010 FCC ID : WS5DSB0010 STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C95.1-1992

More information

DIRECTORY DIRECTORY Introduction SAR Definition System Setup Validation Results...15

DIRECTORY DIRECTORY Introduction SAR Definition System Setup Validation Results...15 DIRECTORY DIRECTORY... 2 1. TESTING LABORATORY... 4 1.1. Identification of the Responsible Testing Laboratory... 4 1.2. Identification of the Responsible Testing Location...4 1.3. Accreditation Certificate...4

More information

Report No:139135R-HPUSP10V01. FCC Test Report

Report No:139135R-HPUSP10V01. FCC Test Report Report No:139135R-HPUSP10V01 FCC Test Report Product Name Model No. : Wireless Microphone System : WMICG4-HU Applicant Address : Coban Technologies, Inc : 11375 W. Sam Houston Parkway S. # 800 Houston,

More information

FCC SAR EVALUATION REPORT

FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 FCC SAR EVALUATION REPORT Product Name: HEXA Pride 8 Trademark: HEXA Model Name: Pride 8 Serial

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test Report Serial No: RFI/RPTE2/RP48909JD015A Supersedes Test Report Serial No: RFI/RPTE1/RP48909JD015A This Test Report Is Issued Under The Authority Of Michael Derby, Radio

More information

Report No:082186R-HPUSP09V01. SAR Test Report. : Eee PC

Report No:082186R-HPUSP09V01. SAR Test Report. : Eee PC SAR Test Report Product Name : Eee PC Model No. : Eee PC 900 Applicant : ASUSTeK COMPUTER INC. Address : 4FL., No. 150, Li-Te Rd., Peitou, Taipei, Taiwan, R.O.C. Date of Receipt : 2008/02/18 Issued Date

More information

FCC Part 22H & 24E Measurement and Test Report

FCC Part 22H & 24E Measurement and Test Report FCC Part 22H & 24E Measurement and Test Report For Shenzhen Concox Information Technology Co., Ltd Floor 4th, Building B, Gaoxinqi Industrial Park, Liuxian 1st Road, District 67, Bao an, Shenzhen, China

More information

For Sky. Phone LLC. FCC Part 22H. FCC Rules: 3G Smart Phone. Report No.: By: Tested By: Manager. Prepared. Shenzhen SEM.

For Sky. Phone LLC. FCC Part 22H. FCC Rules: 3G Smart Phone. Report No.: By: Tested By: Manager. Prepared. Shenzhen SEM. FCC Part 22H & 24E Measurement and Test Report For Sky Phone LLC 1348 Washington Av. Suite 350, Miamii Beach, Florida, F United States FCCC ID: 2ABOSSKYPLATA55 FCC Rules: Product Description: Tested Model:

More information

Intel SAR Test Report

Intel SAR Test Report Intel SAR Test Report Product Name : Notebook Model No. : MS-1491, MS-1492, MS-1493, MS-1494, MS-1495, MS-1496, MS-1497, MS-1498, MS-1499, MS-149A, MS-149B, MS-149C, MS-149D, MS-149E, MS-149F, MS-149G,

More information

UMTS-FDD Band Ⅱ (Part 24E)

UMTS-FDD Band Ⅱ (Part 24E) Page 46 of 89 UMTS-FDD Band Ⅱ (Part 24E) Fundamental Band II - Low Channel-1 Band II - Low Channel-2 Fundamental Band II - Middle Channel-1 Band II - Middle Channel-2 Fundamental Band II - High Channel-1

More information

Test Report FCC ID. sample has been SPORTON INTERNATIONAL FCC ID : YHLBLUSTSELFIE. Page 1 of 45

Test Report FCC ID. sample has been SPORTON INTERNATIONAL FCC ID : YHLBLUSTSELFIE. Page 1 of 45 FCC SAR Test Report Report No. : FA5723033 FCCC SAR Test Report t APPLICANT : CT Asia (HK) Ltd. EQUIPMENT : Smart phone BRAND NAME : BLU MODEL NAME : STUDIO SELFIE FCC ID : YHLBLUSTSELFIE STANDARD : FCC

More information

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015 RADIO TEST REPORT For MODEL NO. 1703 FCC ID: C3K1703 IC ID: 3048A-1703 Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015 FCC CFR47 Part 15 Subpart E Industry Canada RSS-247 Issue 1 Prepared

More information

DECLARATION OF COMPLIANCE SAR RF EXPOSURE EVALUATION FCC & IC

DECLARATION OF COMPLIANCE SAR RF EXPOSURE EVALUATION FCC & IC DECLARATION OF COMPLIANCE SAR RF EXPOSURE EVALUATION FCC & IC Test Lab Information Name CELLTECH LABS INC. Address 21-364 Lougheed Road, Kelowna, B.C. V1X 7R8 Canada Test Lab Accreditation(s) ISO 17025

More information

FCC SAR TEST REPORT. Report No: STS H01. Issued for MOVILES INTELIGENTES S.A. Blvd Vista Hermosa zona 15, VH 1. feature mobile phone

FCC SAR TEST REPORT. Report No: STS H01. Issued for MOVILES INTELIGENTES S.A. Blvd Vista Hermosa zona 15, VH 1. feature mobile phone S T S FCC SAR TEST REPORT Report No: STS1607203H01 Issued for MOVILES INTELIGENTES S.A. Blvd Vista Hermosa 18-19 zona 15, VH 1 Guatemala, C.A Product Name: feature mobile phone L A Brand Name: Model Name:

More information

DIRECTORY 1. TESTING LABORATORY TECHNICAL INFORMATION SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP...

DIRECTORY 1. TESTING LABORATORY TECHNICAL INFORMATION SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP... DIRECTORY 1. TESTING LABORATORY...4 1.1 IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION...4 1.2 ACCREDITATION CERTIFICATE...4 1.3 LIST OF TEST EQUIPMENTS...4 2. TECHNICAL INFORMATION...5 2.1 IDENTIFICATION

More information

ANNEX TO RESOLUTION No. 533, OF SEPTEMBER 10 th 2009.

ANNEX TO RESOLUTION No. 533, OF SEPTEMBER 10 th 2009. ANNEX TO RESOLUTION No. 533, OF SEPTEMBER 10 th 2009. REGULATION FOR CERTIFICATION AND HOMOLOGATION OF TELECOMMUNICATION EQUIPMENTS REGARDING THE EVALUATION OF SPECIFIC ABSORPTION RATE (SAR) 1. Objective

More information

SAR EVALUATION REPORT. Grandstream Networks, Inc.

SAR EVALUATION REPORT. Grandstream Networks, Inc. SAR EVALUATION REPORT For Grandstream Networks, Inc. 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA FCC ID: YZZWP820 Report Type: Original Report Product Type: Enterprise Portable Wi-Fi Phone Report

More information

STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE

STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE FCC SAR Test Report Report No. : FA560515 FCC SAR Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID : FUJITSU LIMITED : Mobile Phone : FUJITSU : F-01H : VQK-F01H STANDARD : FCC 47 CFR Part 2

More information

TRANSMITTER MODEL: KAS-2030M

TRANSMITTER MODEL: KAS-2030M Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved

More information

Model: M /800 MHz Mobile Radio

Model: M /800 MHz Mobile Radio Engineering and Testing for EMC and Safety Compliance Accredited Under NVLAP Lab Code 200061-0 RF Maximum Permissible Exposure (MPE) Report for Controlled and Uncontrolled Environments M/A-COM, Inc. 221

More information

FCC SAR Test Report (Class II Permissive Change)

FCC SAR Test Report (Class II Permissive Change) FCC SAR Test Report (Class II Permissive Change) Product Name : Wireless Motherboard Model No. : TA80TA1 Applicant Address : ELITEGROUP COMPUTER SYSTEMS CO., LTD. : No.239, Sec. 2, Ti Ding Blvd., Taipei,

More information

SAR TEST REPORT. Report No.: Product: Trade Name: Brand Name: \ Model No.: FCC ID: Applicant:

SAR TEST REPORT. Report No.: Product: Trade Name: Brand Name: \ Model No.: FCC ID: Applicant: SAR TEST REPORT Report No.: Product: Trade Name: SET2018-13537 FLX Display Module ROYOLE Brand Name: \ Model No.: FCC ID: IC: Applicant: RY0603 2AGVM-RY0603 20966-RY0603 Royole Corporation Address: 48025

More information

Test. Report. : connectblue. Manufacturer. Model No. FCC ID 4.10, This. 3. This. as UL. Date of Issue: 22 May

Test. Report. : connectblue. Manufacturer. Model No. FCC ID 4.10, This. 3. This. as UL. Date of Issue: 22 May Test Report TESTT REPORT No. : UL-RPT-RP86357JD01A V2.0 Manufacturer Model No. FCC ID IC Certification No. Test Standard(s) : connectblue : OWS451 : PVH0941 : 5325A-0941 : FCC Parts 15. 107, 15.109, 15.207,

More information

TEST REPORT. Test Report No.: /09. Test Standard/s

TEST REPORT. Test Report No.: /09. Test Standard/s TEST REPORT Test Report No.: 1-1837-01-02/09 Testing Laboratory Applicant Inmarsat Global Ltd 99 City Road London EC1Y 1AX/UNITED KINGDOM CETECOM ICT Services GmbH Untertürkheimer Straße 6 10 66117 Saarbrücken/Germany

More information

CERTIFICATE OF COMPLIANCE SAR EVALUATION

CERTIFICATE OF COMPLIANCE SAR EVALUATION 2867 Progress Place, Suite 4D Escondido, CA 92029 U.S.A. TEL (760) 737-3131 FAX (760) 737-9131 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Vulcan Portals Inc. Dates of Test: August

More information

CERTIFICATE OF COMPLIANCE SAR EVALUATION

CERTIFICATE OF COMPLIANCE SAR EVALUATION 2867 Progress Place, Suite 4D Escondido, CA 92029 U.S.A. TEL (760) 737-3131 FAX (760) 737-9131 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Xplore Technologies Dates of Test: July

More information

FCC CFR47 PART 22 SUBPART H FCC CFR47 PART 24 SUBPART E INDUSTRY CANADA RSS-132 ISSUE 2 INDUSTRY CANADA RSS-133 ISSUE 5 CLASS II PERMISSIVE CHANGE

FCC CFR47 PART 22 SUBPART H FCC CFR47 PART 24 SUBPART E INDUSTRY CANADA RSS-132 ISSUE 2 INDUSTRY CANADA RSS-133 ISSUE 5 CLASS II PERMISSIVE CHANGE FCC CFR47 PART 22 SUBPART H FCC CFR47 PART 24 SUBPART E INDUSTRY CANADA RSS-132 ISSUE 2 INDUSTRY CANADA RSS-133 ISSUE 5 CLASS II PERMISSIVE CHANGE CERTIFICATION TEST REPORT FOR EUT: PCI EXPRESS MINI CARD

More information

DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2

DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2 TESTING CERT # 2518.05 DECLARATION OF COMPLIANCE ASSESSMENT Part 1 of 2 Motorola Solutions Inc. EME Test Laboratory Motorola Solutions Malaysia Sdn Bhd (Innoplex) Plot 2A, Medan Bayan Lepas Mukim 12 SWD

More information

CE Radio Test Report

CE Radio Test Report CE Radio Test Report Report No. : ER172910A CE Radio Test Report APPLICANT : Quanta Computer Inc EQUIPMENT : Laptop Computer BRAND NAME : OLPC MODEL NAME : XO-1.75; XO-1.75HS STANDARD : ETSI EN 300 328

More information

Test Report FCC ID. sample has been SPORTON. 1F P. R. Chinaa INTERNATIONAL. Page 1 of 37

Test Report FCC ID. sample has been SPORTON. 1F P. R. Chinaa INTERNATIONAL. Page 1 of 37 FCC SAR Test Report Report No. : FA5109055 FCCC SAR Test Report t APPLICANT : CT Asia EQUIPMENT : Mobile phone BRAND NAME : BLU MODEL NAME : Dash 4.0 Ce FCC ID : YHLBLUDASH40CEE STANDARD : FCC 47 CFR Part

More information

SAR Test Report. : Panasales Clearance centre Pty. Ltd. TA Cellsafe Pty Ltd. : Cellsafe UNIVERAL RADI-CHIP TEST DATES : 2017/5/10 ~ 2017/5/26

SAR Test Report. : Panasales Clearance centre Pty. Ltd. TA Cellsafe Pty Ltd. : Cellsafe UNIVERAL RADI-CHIP TEST DATES : 2017/5/10 ~ 2017/5/26 SAR Test Report Report No. : FA753113 SAR Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Panasales Clearance centre Pty. Ltd. TA Cellsafe Pty Ltd. : Cellsafe UNIVERAL RADI-CHIP : CELLSAFE : UNIVERSAL

More information

DIRECTORY 1. TESTING LABORATORY SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP TISSUE SIMULATING LIQUIDS...

DIRECTORY 1. TESTING LABORATORY SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP TISSUE SIMULATING LIQUIDS... DIRECTORY Report No.: SZ14050068S01 1. TESTING LABORATORY... 4 1.1 IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION... 4 1.2 ACCREDITATION CERTIFICATE... 4 1.3 LIST OF TEST EQUIPMENTS... 4 2. TECHNICAL

More information

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm) Page 41 of 103 9.6. Test Result The test was performed with 802.11b Channel Frequency (MHz) power ANT 1(dBm) power ANT 2 (dbm) power ANT 1(mW) power ANT 2 (mw) Limits dbm / W Low 2412 7.20 7.37 5.248 5.458

More information

FCC 47 CFR Part2(2.1093) ANSI/IEEE C IEEE & Published RF Exposure KDB Procedures. David Huang Checked By

FCC 47 CFR Part2(2.1093) ANSI/IEEE C IEEE & Published RF Exposure KDB Procedures. David Huang Checked By SAR TEST REPORT Report No.: Supersede Report No.:N/A Applicant Product Name PCD, LLC 3G Feature phone Model No. Standards PH201Q Test Date Jun 8 to Jun 9, 2017 Issue Date July 14, 2017 FCC 47 CFR Part2(2.1093)

More information

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L FCC Test Report FCC ID Equipment Model No. Brand Name Applicant Address Standard : N7NHL7688 : Wireless Module : HL7688 : AirPrime : Sierra Wireless Inc. Received Date : Jul. 12, 2016 : 13811 Wireless

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 2.4GHz LE MODULE MODEL NUMBER: RN4020 REPORT NUMBER: 14U17191-1 ISSUE DATE: MARCH 21, 2014

More information

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54 TEST CERTIFICATION FOR: FCC Certification NAME OF THE EQUIPMENT UNDER TEST: Serial number: Wireless conference access point Type: CONFIDEA WCAP G3 1440077150000C1 Reference / model (P/N): 71.98.0033 V

More information

TEST SUMMARY Seite 2 von 31. Prüfbericht - Nr.: Test Report No ANTENNA REQUIREMENT RESULT: Pass

TEST SUMMARY Seite 2 von 31. Prüfbericht - Nr.: Test Report No ANTENNA REQUIREMENT RESULT: Pass Prüfbericht - Nr.: Test Report No. Seite 2 von 31 Page 2 of 31 TEST SUMMARY 5.1.1 ANTENNA REQUIREMENT RESULT: Pass 5.1.2 PEAK OUTPUT POWER RESULT: Pass 5.1.3 26DB BANDWIDTH RESULT: Pass 5.1.4 FREQUENCY

More information

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 XBee Series 2 OEM RF Module Model No.: XBEE2 Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 In Accordance With Federal Communications Commission (FCC) Part 15, Subpart C, Section

More information

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated Page 1 of 17 FCC 15.209 & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report for A Acer Incorporated 8F., No.88, Sec. 1, Xintai 5th Rd., Xizhi, New Taipei City 22181, Taiwan (R.O.C) Product

More information

FCC SAR EVALUATION REPORT

FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 FCC SAR EVALUATION REPORT Product Name: Android Smart POS Trademark: Anlinx Model Name: PT7003

More information