1 Test Report issued under the responsibility of: SGS-CSTC TEST REORT COMMISSION REGULATION (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European arliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment Report Reference No.... : Tested by (name + signature)... : Hugh Cao Approved by (name + signature)... : Karen Xie GZES Date of issue... : Total number of pages... : Testing Laboratory... : SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab Guangzhou Address... : 198 Kezhu Road, Scientech ark, Guangzhou Economic & Technology Development District, Guangzhou, Guangdong, China Applicant s name... : Dongguan City Tianhua hotoelectric Technology Co., Ltd. Address... : 2 nd Road, Jinqianling Industrial Zone, Jitigang Village, Huangjiang Town, Dongguan, Guangdong, China Manufacturer s name... : Dongguan City Tianhua hotoelectric Technology Co., Ltd. Address... : 2 nd Road, Jinqianling Industrial Zone, Jitigang Village, Huangjiang Town, Dongguan, Guangdong, China Test specification: Standard... : COMMISSION REGULATION (EU) No 1194/2012 Test procedure... : Er IM test Report Stage... : stage 1 stage 2 stage 3 Non-standard test method..: None Test Report Form No.... : _C Test Report Form(s) Originator... : SGS-CSTC Master TRF... : SGS-CSTC Standards Technical Services Co., Ltd. (SGS-CSTC), Guangzhou,. R. China. All rights reserved. This publication may be produced in whole or in part for non-commercial purposes as long as SGS-CSTC is acknowledged as copyright owner and source of the material. SGS-CSTC takes no responsibility for and will not assume liability for damages resulting from the reader s interpretation of the reproduced material due to its placement and context

2 age 2 of 24 Report No.: GZES Test item description... : Trade Mark... : Factory... : Model/Type reference... : Ratings... : Standard... : LED Touch Lamp (LED module) Dongguan City Tianhua hotoelectric Technology Co., Ltd. 2 nd Road, Jinqianling Industrial Zone, Jitigang Village, Huangjiang Town, Dongguan, Guangdong, China EH1622 Incandescent light bulbs EN DC 12 V; 550 ma; 5 W LED; 330 lm; h; Class III CIE 84 L2(A)005 CIE S 010 Halogen incandescent light bulbs EN CIE 84 L2(A)005 CIE S 010 Compact fluorescent lamps with integrated control gear EN at present 34A/ 1701/CDV CIE 84 L2(A)005 EN High intensity discharge lamps EN CIE 84 L2(A)005 EN EN Light emitting diode lamps EN CIE 84 L2(A)005 EN Light emitting diode modules IEC at present 34A/ 1659/CDV CIE 15 CIE 63 IEC/TR CIE 15 CIE 63 IEC/TR CIE 15 CIE 13.3 CIE 63 IEC/TR EN at present 34A/ 1624/CD CIE 15 CIE 13.3 CIE 63 IEC/TR pren CIE 63 EN CIE 63 EN L2(A)005 pren lighting transformers (halogen and LED) IEC , at present 34C/1019/CDV Fluorescent lamp controlgear EN replacing EN High intensity discharge lamp controlgear IEC , at present 34C/1016/CDV

3 age 3 of 24 Report No.: GZES Summary of testing: The sample(s) tested complies with the requirements of COMMISSION REGULATION (EU) No 1194/2012. The sample(s) also tested complies with the requirements of stage 6 of COMMISSION REGULATION (EC) No 244/ (EC) No 859/2009 for non-directional lamp. These tests were conducted by test lab that fulfils the requirements of standard ISO/IEC When determining the test conclusion, the Measurement Uncertainty of test has been considered. LED driver YHGD (input 100 V V; 50 Hz / 60 Hz; output 550 ma; 12 V DC; ta 35 C; tc 60 C) used for all tests. The LED module was test independently to the luminaire, during all tests luminaire keeping the temperature of tc point of LED module between 75 ºC 80 ºC. Copy of marking plate Rating label: Free access websites:

4 age 4 of 24 Report No.: GZES ackaging:

5 age 5 of 24 Report No.: GZES Test item particulars... : Lamp cap... : Lamp type... : CFL / LED / Mains-voltage filament lamps / other filament lamps / High-intensity discharge lamps: / other lamps: Bulb type... : Non-directional Mass of the equipment... : Commission received from... Dongguan City Tianhua hotoelectric Technology Co., Ltd. Date... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : Date (s) of performance of tests... : to General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. This document is issued by the Company subject to its General Conditions of Service, available on request or accessible at and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. Throughout this report a comma (point) is used as the decimal separator. General product information: Non-directional LED modules incorporated in class III table luminaires.

6 age 6 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict ANNEX I roduct information requirements for special purpose products 1. If the chromaticity coordinates of a lamp always fall within the following range: x < 0,270 or x > 0,530 y < - 2,3172x 2 + 2,3653x 0,2199 or y > - 2,3172x 2 + 2,3653x 0,1595 x: y: The chromaticity coordinates shall be stated in the technical documentation file, which shall indicate that these coordinates make them a special purpose product. 2. For all special purpose products, the intended purpose shall be stated in all forms of product information, together with the warning that they are not intended for use in other applications. The technical documentation file shall list the technical parameters that make the product design specific for the stated intended purpose. If needed, the parameters shall be listed in such a way as to avoid disclosing commercially sensitive information linked to the manufacturer s intellectual property rights. If the product is placed on the market in a packaging containing to be visibly displayed to the end-user prior to purchase, the following information shall be clearly and prominently indicated on the packaging and in all other forms of product information: (a) the intended purpose; and (b) that it is not suitable for household room illumination. ANNEX III Ecodesign requirements 1 ENERGY EFFICIENCY REQUIREMENTS 1.1 Energy efficiency requirements for directional lamps Table 1 Lamps operating on external halogen lamp control gear Lamps operating on external LED lamp control gear Fluorescent lamps of 16 mm diameter (T5 lamps) and 4- pin single capped fluorescent lamps operating on external fluorescent lamp control gear Other lamps operating on external fluorescent lamp control gear Lamps operating on external high-intensity discharge lamp control gear

7 age 7 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict Compact fluorescent lamps with colour rendering index 90 Lamps with anti-glare shield Table 2 The maximum EEI of directional lamps (See Annex 1) Stage 3 For mains-voltage filament lamps shall apply only if no later than 30 September 2015, evidence is produced by the Commission through a detailed market assessment and communicated to the Consultation Forum that there are mainsvoltage lamps on the market that are: compliant with the maximum EEI requirement in stage 3; affordable in terms of not entailing excessive costs for the majority of end-users; broadly equivalent in terms of consumerrelevant functionality parameters to mainsvoltage filament lamps available on the date of entry into force of this Regulation, including in terms of luminous fluxes spanning the full range of reference luminous fluxes listed in Table 6; Compatible with equipment designed for installation between the mains and filament lamps available on the date of entry into force of this Regulation according to state-of-the-art requirements for compatibility. 1.2 Energy efficiency requirements for lamp control gear Stage 2 Stage 2 Stage 2 Stage 3 Stage 3 Stage 3 The no-load power of a lamp control gear intended for use between the mains and the switch for turning the lamp load on/off shall not exceed 1,0 W..: For lamp control gear with output power () over 250 W, the no-load power limits shall be multiplied by /250 W : The efficiency of a halogen lamp control gear shall be at least 0,91 at 100 % load : The no-load power of a lamp control gear intended for use between the mains and the switch for turning the lamp load on/off shall not exceed 0,50 W...: For lamp control gear with output power () over 250 W, the no-load power limits shall be multiplied by /250 W : The standby power of a lamp control gear shall not exceed 0,50 W.: Limit: Limit: 2 FUNCTIONALITY REQUIREMENTS 2.1 Functionality requirements for directional lamps other than LED lamps Table 3 Functionality requirements for directional compact (see Annex 2) fluorescent lamps If the lamp cap is a standardised type also used with filament lamps, then as from stage 2, the lamp shall comply with state-of-the-art requirements for compatibility with equipment designed for installation between the mains and filament lamps.

8 age 8 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict Table 4 Functionality requirements for other directional lamps (excluding LED lamps, compact fluorescent lamps and high-intensity discharge lamps) (see Annex 3) 2.2 Functionality requirements for non-directional and directional LED lamps Table Stage 2 Functionality requirements for non-directional and (see Annex 4) directional LED lamps If the lamp cap is a standardised type also used with filament lamps, then as from stage 2 the lamp shall comply with state-of-the-art requirements for compatibility with equipment designed for installation between the mains and filament lamps. Functionality requirement for equipment designed for installation between the mains and the lamps Equipment designed for installation between the mains and the lamps shall comply with state-ofthe-art requirements for compatibility with lamps whose energy efficiency index is at most: 0,24 for non-directional lamps (assuming that Ф use = total rated luminous flux), 0,40 for directional lamps. A dimming control device is switched on at its lowest control setting for which the operated lamps consume power, the operated lamps shall emit at least 1 % of their luminous flux at full load.. : A luminaire is placed on the market and intended to be marketed to the end-users, and lamps that the end- user can replace are included with the luminaire, these lamps shall be of one of the two highest energy classes, according to Commission Delegated Regulation (EU) No 874/2012, with which the luminaire is labelled to be compatible. 3 RODUCT INFORMATION REQUIREMENTS 3.1 roduct information requirements for directional lamps Stage 1 The following information shall be provided as from stage 1, except where otherwise stipulated. These information requirements do not apply to: filament lamps not fulfilling the efficacy requirements of Stage 2, LED modules when marketed as part of a luminaire from which they are not intended to be removed by the end-user. In all forms of product information, the term energy-saving lamp or any similar product related promotional statement about lamp efficacy may be used only if the energy efficiency index of the lamp (calculated in accordance with the method set out in point 1.1 of this Annex) is 0,40 or below Information to be displayed on the lamp itself

9 age 9 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict Lamps other than high-intensity discharge lamps, the value and unit ( lm, K and ) of the nominal useful luminous flux, of the colour temperature and of the nominal beam angle shall be displayed in a legible font on the surface of the lamp. Information to be visibly displayed to end-users, prior to their purchase, on the packaging and on free access websites The information in paragraphs (a) to (o) below shall be displayed on free access websites and in any other form the manufacturer deems appropriate. If the product is placed on the market in a packaging containing information to be visibly displayed to the end- users, prior to their purchase, the information shall also be clearly and prominently indicated on the packaging. The information does not need to use the exact wording on the list below. It may be displayed in the form of graphs, drawings or symbols rather than text. (a) Nominal useful luminous flux displayed in a font at least twice as large as any display of the nominal lamp power; (b) Nominal life time of the lamp in hours (not longer than the rated life time); (c) Colour temperature, as a value in Kelvins and also expressed graphically or in words; (d) Number of switching cycles before premature failure; (e) Warm-up time up to 60 % of the full light output (may be indicated as instant full light if less than 1 second); (f) A warning if the lamp cannot be dimmed or can be dimmed only on specific dimmers; in the latter case a list of compatible dimmers shall be also provided on the manufacturer's website; (g) If designed for optimum use in non-standard conditions (such as ambient temperature Ta 25 C or specific thermal management is necessary), information on those conditions; (h) Lamp dimensions in millimetres (length and largest diameter); (i) Nominal beam angle in degrees; (j) If the lamp s beam angle is 90and its useful luminous flux as defined in point 1.1 of this Annex is to be measured in a 120cone, a warning that the lamp is not suitable for accent lighting; (k) If the lamp cap is a standardised type also used with filament lamps, but the lamp s dimensions are different from the dimensions of the filament lamp(s) that the lamp is meant to replace, a drawing comparing the lamp s dimensions to the dimensions of the filament lamp(s) it replaces;

10 age 10 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict (l) An indication that the lamp is of a type listed in the first column of Table 6 may be displayed only if the luminous flux of the lamp in a 90 cone (Ф90) is not lower than the reference luminous flux indicated in Table 6 for the smallest wattage among the lamps of the type concerned. (m) An equivalence claim involving the power of a replaced lamp type may be displayed only if the lamp type is listed in Table 6 and if the luminous flux of the lamp in a 90 cone (Ф90) is not lower than the corresponding reference luminous flux in Table 6. If the lamp contains mercury: (n) Lamp mercury content as X,X mg; (o) Indication of which website to consult in case of accidental lamp breakage to find instructions on how to clean up the lamp debris. Information to be made publicly available on free-access websites and in any other form the manufacturer deems appropriate As a minimum, the following information shall be expressed at least as values. (a) The information specified in point 3.1.2; (b) Rated power (0,1 W precision); (c) Rated useful luminous flux; (d) Rated lamp life time; (e) Lamp power factor; (f) Lumen maintenance factor at the end of the nominal life (except for filament lamps); (g) Starting time (as X,X seconds); (h) Colour rendering; (i) Colour consistency (only for LEDs); (j) Rated peak intensity in candela (cd); (k) Rated beam angle; (l) If intended for use in outdoor or industrial applications, an indication to this effect; (m) Spectral power distribution in the range nm; If the lamp contains mercury: (n) Instructions on how to clean up the lamp debris in case of accidental lamp breakage; (o) Recommendations on how to dispose of the lamp at the end of its life for recycling in line with Directive 2012/19/EU of the European arliament and of the Council ( 1 ). Additional product information requirements for LED lamps replacing fluorescent lamps without integrated ballast

11 age 11 of 24 Report No.: GZES Clause Requirement + Test Result - Remark Verdict Stage Stage 2 Manufacturers of LED lamps replacing fluorescent lamps without integrated ballast shall publish a warning on publicly available free-access websites and in any other form they deem appropriate that the overall energy efficiency and light distribution of any installation that uses such lamps are determined by the design of the installation. Claims that an LED lamp replaces a fluorescent lamp without integrated ballast of a particular wattage may be made only if: The luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube, and The luminous flux of the LED lamp is not lower than the luminous flux of the fluorescent lamp of the claimed wattage. The luminous flux of the fluorescent lamp shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent lamp in Commission Regulation (EC) No 245/2009, and The wattage of the LED lamp is not higher than the wattage of the fluorescent lamp it is claimed to replace. The technical documentation file shall provide the data to support such claims. roduct information requirements for equipment other than luminaires, designed for installation between the mains and the lamps If the equipment provides no compatibility with any of the energy-saving lamps according to part 2.3 of this Annex, a warning that the equipment is not compatible with energy-saving lamps shall be published on publicly available free-access websites and in other forms the manufacturer deems appropriate. 3.4 roduct information requirements for lamp control gears Stage 2 the following information shall be published on publicly available free access websites and in other forms the manufacturer deems appropriate: Indication that the product is intended to be used as a lamp control gear, If applicable, the information that the product may be operated in no-load mode.

12 ANNEX 1 age 12 of 24 Report No.: GZES Table 2: The maximum EEI of directional lamps TABLE 1 CORRECTION FACTORS cor = rated 1,06 cor = rated 1,10 cor = rated 0,80 cor = rated 0,85 cor = Sample Фuse (lm): rated (W): Energy efficiency index (EEI) Test voltage (V): Average Ф use (lm): Average rated (W): cor (W): Average EEI: Energy efficiency class ref (W): Ф use < 1300 lm: Ф use 1300 lm: ref = 0,07341Ф use

13 ANNEX 1 age 13 of 24 Report No.: GZES Table 2: The maximum EEI of directional lamps TABLE 2 Maximum energy efficiency index (EEI) Lamp type Mainsvoltage filament lamps: Other filament lamps: Highintensity discharge lamps: Other lamps: Application stage Limit for Stage 1 If Ф use > 450 lm: 1,75 Ф use = lm Limit for Stage 2 Limit for Stage 3 Calculated EEI Verdict 1,75 0,95 If Ф use 450 lm: 1,20; If Ф use > 450 lm: 0,95 0,95 0,95 Ф use = lm 0,50 0,50 0,36 0,50 0,50 0,20

14 ANNEX 2 age 14 of 24 Report No.: GZES Table 3: Functionality requirements for directional compact fluorescent lamps Type reference: Functionality parameter Limit for Stage 1 except where indicated otherwise Limit for Stage 3 Lamp survival factor at 6000 h From 1 March 2014: 0,50 0,70 Lumen maintenance At h: 80 % At h: 83 % At h: 70 % Number of switching cycles half the lamp lifetime expressed in hours: if lamp starting time > 0,3 s lamp lifetime expressed in hours: if lamp starting time > 0,3 s Starting time (s) < 2,0 < 1,5; if < 10 W < 1,0; if 10 W Lamp warm-up time to 60 % Ф (s) < 40 < 100 for lamps containing mercury in amalgam form < 40 < 100 for lamps containing mercury in amalgam form remature failure rate 5,0 % at 500 h 5,0 % at 1000 h Lamp power factor (F) 0,50 if < 25 W 0,90 if 25 W 0,55 if < 25 W 0,90 if 25 W Colour rendering (Ra) if the lamp is intended for outdoor or industrial applications according to point 3.1.3(l) of this Annex if the lamp is intended for outdoor or industrial applications according to point 3.1.3(l) of this Annex Average results Verdict

15 ANNEX 2 age 15 of 24 Report No.: GZES Table 3: Functionality requirements for directional compact fluorescent lamps Tests results for 20 samples: Sample Number of switching cycles before failure Starting time (s) Lamp warm-up time to 60% Ф (s) Colour rendering (Ra)

16 age 16 of 24 Report No.: GZES ANNEX 3 Table 4: Functionality requirements for other directional lamps (excluding LED lamps, compact fluorescent lamps and high-intensity discharge lamps) Type reference: Functionality parameter Rated lamp lifetime at 50 % lamp survival Lumen maintenance Number of switching cycles Starting time (s) Lamp warmup time to 60 % Ф (s) remature failure rate Lamp power factor (F) 1000 h Limit for Stage 1 and h in stage 2000 h for extra low voltage lamps not complying with the stage 3 filament lamp efficiency requirement in point 1.1 of this Annex 80 % at 75 % of rated average lifetime four times the rated lamp life expressed in hours: < 0,2 1,0 5,0 % at 100 h ower 25 W: 0,9 ower 25 W: 0,5 Limit for Stage h 4000 h for extra low voltage lamps 85 % at 75 % of rated average lifetime four times the rated lamp life expressed in hours: < 0,2 1,0 5,0 % at 200 h ower 25 W: 0,9 ower 25 W: 0,5 Average results Verdict

17 age 17 of 24 Report No.: GZES ANNEX 3 Table 4: Functionality requirements for other directional lamps (excluding LED lamps, compact fluorescent lamps and high-intensity discharge lamps) Tests results for 20 samples: Sample Number of switching cycles Starting time (s) Lamp warm-up time to 60% Ф (s)

18 ANNEX 4 age 18 of 24 Report No.: GZES Table 5: Functionality requirements for non-directional and directional LED lamps Type reference: Functionalit y parameter Limit for Stage 1 except where indicated otherwise Lamp survival factor at 6000 h From 1 March 2014: 0,90 Lumen Maintenance at 6000 h From 1 March 2014: 0,80 Number of switching cycles if rated lamp life h otherwise half the rated lamp life expressed in hours: Starting time (s) EH1622 Lamp warmup time to 95 % Ф (s) < 0,5 < 2 rematur e failure rate 5,0 % at 1000 h Colour rendering (Ra) if the lamp is intended for outdoor or industrial applications in accordance with point 3.1.3(l) of this Annex Colour consistency Variation of chromaticity coordinates within a sixstep MacAdam ellipse or less Lamp power factor (F) 2 W: no requir ement 2 W < 5 W: F > 0,4 5 W < 25 W: F > 0,5 > 25 W: F > 0,9 Average results 1 0,83 > ,47 0, ,3 2,6 Verdict

19 ANNEX 4 age 19 of 24 Report No.: GZES Table 5: Functionality requirements for non-directional and directional LED lamps Tests results for 20 samples: Lumen Sample Maintenance at 6000 h (%) Number of switching cycles before failure Starting time (s) Lamp warm-up time to 95%Ф (s) Colour rendering (Ra) 1 84,0 > ,471 0,5 81,3 2 80,9 > ,445 0,5 82,1 3 86,4 > ,459 0,5 81,6 4 87,2 > ,458 0,5 82,3 5 85,0 > ,489 0,5 81,6 6 83,7 > ,476 0,5 81,7 7 81,7 > ,448 0,5 81,4 8 84,2 > ,454 0,5 81,4 9 86,1 > ,467 0,5 81, ,9 > ,478 0,5 81, ,9 > ,453 0,5 82, ,0 > ,475 0,5 82, ,2 > ,467 0,5 82, ,6 > ,481 0,5 81, ,4 > ,424 0,5 81, ,2 > ,436 0,5 81, ,9 > ,445 0,5 81, ,8 > ,464 0,5 81, ,1 > ,452 0,5 82, ,1 > ,471 0,5 81,3

20 ANNEX 5 Additional requirement of 244/2009/EU age 20 of 24 Report No.: GZES ANNEX II Ecodesign requirements for non-directional household lamps: 1 LAM EFFICACY REQUIREMENTS Table 1 Maximum rated power (max) for a given rated luminous flux (Ф) (W) Clear lamps Stages 1 to 5: 0,8 * (0,88 Ф+0,049Ф) Stage 6: 0,6 * (0,88 Ф+0,049Ф) Average Luminous flux (lm) Calculated max (W) Average wattage (W) Non-clear lamps Stages 1 to 5: 0,24 Ф+0,0103Ф Stages 6: 0,24 Ф+0,0103Ф Average Luminous flux (lm) 365,07 Calculated max (W) 8,35 Average wattage (W) 7,26 Table 2 Maximum rated power (max) for a given rated luminous flux (Ф) (W) Clear lamps 60 lm Ф 950 lm in Stage 1: max = 1,1 * (0,88 Ф+0,049Ф) Clear lamps 60 lm Ф 725 lm in Stage 2: max = 1,1 * (0,88 Ф+0,049Ф) Clear lamps 60 lm Ф 450 lm in Stage 3: max = 1,1 * (0,88 Ф+0,049Ф) Clear lamps with G9 or R7s cap in Stage 6: max = 0,8 * (0,88 Ф+0,049Ф) Average Luminous flux (lm) Calculated max (W) Average wattage (W) Table 3 Correction factors filament lamp requiring external power supply: max/1,06 discharge lamp with cap GX53: max/0,75 non-clear lamp with colour rendering index 90 and 0,5 * (0,88 Ф+0,049Ф): max/0,85 discharge lamp with colour rendering index 90 and Tc K: max/0,76 non-clear lamp with second envelope and 0,5 * (0,88 Ф+0,049Ф): max/0,95 LED lamp requiring external power supply: max/1,1 Average Luminous flux (lm) 365,07 Calculated max (W) 7,59 Average wattage (W) 7,26 3 RODUCT INFORMATION REQUIREMENTS ON LAMS 3.1 For non-directional household lamps, the following information shall be provided as from Stage 2, except where otherwise stipulated Information to be visibly displayed prior to purchase to end-users on the packaging and on free access websites

21 ANNEX 5 Additional requirement of 244/2009/EU age 21 of 24 Report No.: GZES (a) When the nominal lamp power is displayed outside the energy label in accordance with Directive 98/11/EC, the nominal luminous flux of the lamp shall also be separately displayed in a font at least twice as large as the nominal lamp power display outside the label (b) Nominal life time of the lamp in hours (not higher than the rated life time) (c) Number of switching cycles before premature lamp failure (d) Colour temperature (also expressed as a value in Kelvins) (e) Warm-up time up to 60 % of the full light output (may be indicated as instant full light if less than 1 second) (f) A warning if the lamp cannot be dimmed or can be dimmed only on specific dimmers (g) If designed for optimal use in non-standard conditions (such as ambient temperature Ta 25 C), information on those conditions; (h) Lamp dimensions in millimeters (length and diameter) (i) If equivalence with an incandescent lamp is claimed on the packaging, the claimed equivalent incandescent lamp power (rounded to 1 W) shall be that corresponding in Table 6 to the luminous flux of the lamp contained in the packaging. (j) The term energy saving lamp or any similar product related promotional statement about lamp efficacy may only be used if the lamp complies with the efficacy requirements applicable to non-clear lamps in Stage 1 according to Tables 1, 2 and 3. If the lamp contains mercury (k) Lamp mercury content as X,X mg (l) Indication which website to consult in case of accidental lamp breakage to find instructions on how to clean up the lamp debris 3.2 Information to be made publicly available on free-access websites (a) The information specified in point 3.1 (b) Rated wattage (0,1 W precision) (c) Rated luminous flux (d) Rated lamp life time (e) Lamp power factor (f) Lumen maintenance factor at the end of the nominal life (g) Starting time (as X,X seconds) (h) Colour rendering If the lamp contains mercury

22 ANNEX 5 Additional requirement of 244/2009/EU age 22 of 24 Report No.: GZES (i) Instructions on how to clean up the lamp debris in case of accidental lamp breakage (j) Recommendations on how to dispose of the lamp at its end of life ANNEX VI Energy efficiency classes The energy efficiency class of a lamp shall be determined as follows: Lamps operating on external halogen lamp control gear cor = rated 1,06 Lamps operating on external LED lamp control gear cor = rated 1,10 = 7,26 x 1,10 = 7,99 Fluorescent lamps of 16 mm diameter (T5 lamps) and 4-pin single capped fluorescent lamps cor = rated 1,10 operating on external fluorescent lamp control gear cor = Other lamps operating on external fluorescent lamp control gear Lamps operating on external high-intensity discharge lamp control gear cor = rated 1,10 Lamps operating on external low pressure sodium lamp control gear cor = rated 1,15 For models with Φ use < lumen: 365,07 lm ref = 0,88 Φ use + 0,049 use: 34,70 W For models with Φ use lumen: ref = 0,07341Φ use : EEI = cor / ref : 7,99 W / 34,70 W = 0,23 Energy efficiency class EEI for nondirectional lamps EEI for directional lamps A++ EEI 0,11 EEI 0,13 A+ 0,11 < EEI 0,17 0,13 < EEI 0,18 A 0,17 < EEI 0,24 0,18 < EEI 0,40 0,23 B 0,24 < EEI 0,60 0,40 < EEI 0,95 C 0,60 < EEI 0,80 0,95 < EEI 1,20 D 0,80 < EEI 0,95 1,20 < EEI 1,75 E EEI > 0,95 EEI > 1,75

23 ANNEX 6 hoto documentation age 23 of 24 Report No.: GZES Type of equipment, model: EH1622 Details of: General view View: [ ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom Details of: LED lamp View: [ ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom

24 ANNEX 6 hoto documentation age 24 of 24 Report No.: GZES Details of: LED modules View: [ ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom End of Report - - -

Dongguan Bai lida Optoelectronics Technology Co. Ltd. TEST REPORT

Dongguan Bai lida Optoelectronics Technology Co. Ltd. TEST REPORT Dongguan Bai lida Optoelectronics Technology Co. Ltd. TEST REORT repared For: Dongguan Bai lida Optoelectronics Technology Co. Ltd. No.10 Huan Cun Bei Road,Baihao precinct,houjie Town,Dongguan,Guangdong,523957,China.

More information

Reference No.: WTF13F R1N Page 2 of 13

Reference No.: WTF13F R1N Page 2 of 13 Reference No.: WTF13F0604805R1N age 2 of 13 Test model. : HV4202-4(180.003408) Type of test objects. : LED endant Lamp Trademark:.... : --- Subcontract / test (clause)...: Address....: Order description...:

More information

APPLICATION FOR TEST REPORT. On Behalf of JIANGMEN BAOTIAN LIGHTING CO., LTD. CEILING LAMP. Model: MX

APPLICATION FOR TEST REPORT. On Behalf of JIANGMEN BAOTIAN LIGHTING CO., LTD. CEILING LAMP. Model: MX SHEZHE LCS COMLIACE TESTIG LABORATORY LTD. REORT O.: LCS1406050089S ALICATIO FOR TEST REORT On Behalf of JIAGME BAOTIA LIGHTIG CO., LTD. CEILIG LAM Model: MX900109-3 repared For : JIAGME BAOTIA LIGHTIG

More information

Reference No.: WTF15F N Page 2 of 20

Reference No.: WTF15F N Page 2 of 20 Reference No.: WTF15F0933084N age 2 of 20 Test sample. : LED floor lamp Type of test objects : F49951SS(37660009/01) Trademark:. : --- Subcontract / test (clause) :. Address...: Order description...: Evaluation

More information

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems Test Report issued under the responsibility of: TEST REORT and/or EN 62471 hotobiological safety of lamps and lamp systems Report Reference No.... : GZES150400337431 Tested by (name + signature)... : Change

More information

TEST REPORT EN 62233: 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

TEST REPORT EN 62233: 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure TEST REORT Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure Report Reference No....: GZES110400210331 Tested by (name + signature)...:

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REPORT IEC 60825-1 Safety of laser products - Part 1: Equipment classification and requirements Report Number.... : GZES160801248631 Date of issue...

More information

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft. COMMISSION REGULATION (EC) No /

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft. COMMISSION REGULATION (EC) No / EN EN EN COMMISSION OF THE EUROPEAN COMMUNITIES Brussels, xxx C(2008) YYY final Draft COMMISSION REGULATION (EC) No / of implementing Directive 2005/32/EC of the European Parliament and of the Council

More information

Candle 6,000 hours. Compact Fluorescent Lamps Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Candle 6,000 hours. Compact Fluorescent Lamps Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features. GE Lighting Candle 6,000 hours DATA SHEET Compact Fluorescent Lamps Integrated 5W, 7W, 9W and 11W Product information The 6,000 hours CFL candle lamps offer traditional incandescent shape, long life and

More information

Spherical T2 8,000 hours

Spherical T2 8,000 hours GE Lighting Spherical T2 8,000 hours DATA SHEET Compact Fluorescent Lamps Integrated 5W and 7W information The T2 8,000 hours spherical lamps offer traditional incandescent shape and sizes, long life and

More information

Candle 8,000 hours. Compact Fluorescent Lamps Integrated. 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Application areas.

Candle 8,000 hours. Compact Fluorescent Lamps Integrated. 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Application areas. GE Lighting Candle 8, hours DATA SHEET Compact Fluorescent Lamps Integrated 7W, 9W and 11W information The 8, hours CFL candle lamps offer traditional incandescent shape, long life and elegant light. Suitable

More information

TEST REPORT IEC Photobiological safety of lamps and lamp systems

TEST REPORT IEC Photobiological safety of lamps and lamp systems TEST REORT hotobiological safety of lamps and lamp systems Report Reference No.... : SHES170800821171 Date of issue... : 2017-09-04 Total number of pages... : 15 Testing Laboratory... : Address... : Applicant

More information

REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND RELATED EQUIPMENT ACCORDING TO THE EC REGULATION 1194/2012

REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND RELATED EQUIPMENT ACCORDING TO THE EC REGULATION 1194/2012 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND

More information

Ecodesign requirements for fluorescent and high intensity discharge lighting products

Ecodesign requirements for fluorescent and high intensity discharge lighting products Federation of National Manufacturers Associations for Luminaires and Electrotechnical Components for Luminaires in the European Union Guide of the European Lighting Industry (CELMA & ELC) for the application

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 26.9.2012 Official Journal of the European Union L 258/1 II (Non-legislative acts) REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the

More information

Technology: Lighting Units

Technology: Lighting Units Triple E Register Eligibility Criteria Category: Lighting Technology: Lighting Units Lighting units are products that are specifically designed to provide high efficiency interior or exterior illumination.

More information

This is to attest that

This is to attest that This is to attest that BELL-SOUTHCN TESTING LABORATORY (SHENZHEN) JUNXIANG DA BUILDING, NUMBER 9 OF ZHONGSHAN PARK ROAD NANSHAN DISTRICT, SHENZHEN, GUANGDONG, 518052 PEOPLE'S REPUBLIC OF CHINA Testing

More information

COMPARATIVE STUDY OF LIGHT SOURCES FOR HOUSEHOLD

COMPARATIVE STUDY OF LIGHT SOURCES FOR HOUSEHOLD Management Systems in Production Engineering 2017, No 1 (25), pp 35-41 Date of submission of the article to the Editor: 06/2016 Date of acceptance of the article by the Editor: 10/2016 DOI 10.1515/mspe-2017-0005

More information

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents 2009R0245 EN 13.04.2010 001.001 1 This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents B COMMISSION REGULATION (EC) No 245/2009 of 18

More information

(Text with EEA relevance) (OJ L 258, , p. 1)

(Text with EEA relevance) (OJ L 258, , p. 1) 02012R0874 EN 07.03.2017 002.001 1 This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING) LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): C10-D54W-XXE

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING) LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): CE6-40W-XXE

More information

ON A POSSIBLE COMMISSION REGULATION IMPLEMENTING DIRECTIVE 2005/32/EC WITH REGARD TO TERTIARY SECTOR LIGHTING PRODUCTS

ON A POSSIBLE COMMISSION REGULATION IMPLEMENTING DIRECTIVE 2005/32/EC WITH REGARD TO TERTIARY SECTOR LIGHTING PRODUCTS WORKING DOCUMENT ON A POSSIBLE COMMISSION REGULATION IMPLEMENTING DIRECTIVE 2005/32/EC WITH REGARD TO TERTIARY SECTOR LIGHTING PRODUCTS Chapter 1 Subject matter and scope This Regulation establishes ecodesign

More information

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The

More information

INTRODUCING: SAMSUNG ELECTRONICS. LED Lamps Technical data sheet B2C Essential Range

INTRODUCING: SAMSUNG ELECTRONICS. LED Lamps Technical data sheet B2C Essential Range INTRODUCING: SAMSUNG ELECTRONICS LED Lamps Technical data sheet B2C Lighting Marketing Group [EU_Q1 2013] Ver.1.3 20 Feb 2013 Light up your Imagination with new LED lighting! A new light with a bright

More information

PARATHOM PAR ADV 4.8 W/840 GU10

PARATHOM PAR ADV 4.8 W/840 GU10 PARATHOM PAR16 35 36 ADV 4.8 W/840 GU10 PARATHOM PAR16 advanced Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows

More information

BASIC T5 Short Emergency Lighting

BASIC T5 Short Emergency Lighting osram.com BASIC T5 Short Emergency Lighting Versatile solutions for emergency lighting applications Basic T5 EL Basic T5 EL QT-ECO TECHNICAL INFORMATION 01 Benefits Suitable for emergency power operation

More information

PARATHOM PAR ADV 5.3 W/827 GU10

PARATHOM PAR ADV 5.3 W/827 GU10 PARATHOM PAR16 50 36 ADV 5.3 W/827 GU10 PARATHOM PAR16 advanced Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows

More information

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description. GE Lighting Biax T/E Triple Biax Compact Fluorescent Lamps Non-Integrated W, W, W, 32W and 42W Product description Ultra compact energy saving CFL lamps with triple-tube design give an ideal light source

More information

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft. COMMISSION REGULATION (EC) No /

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft. COMMISSION REGULATION (EC) No / EN EN EN COMMISSION OF THE EUROPEAN COMMUNITIES Draft Brussels, xxx C(2008) YYY final COMMISSION REGULATION (EC) No / Of implementing Directive 2005/32/EC of the European Parliament and of the Council

More information

PARATHOM PAR W/830 GU10

PARATHOM PAR W/830 GU10 PARATHOM PAR16 35 36 3.1 W/830 GU10 PARATHOM advanced PAR16 Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows

More information

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

PRODUCT DATASHEET P CLAS B 40 FR 5.7 W/2700K E14

PRODUCT DATASHEET P CLAS B 40 FR 5.7 W/2700K E14 P CLAS B 40 FR 5.7 W/2700K E14 PARATHOM CLASSIC B LED lamps, classic mini-candle shape AREAS OF APPLICATION Domestic applications General illumination Chandeliers Outdoor applications only in suitable

More information

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:

More information

FLYYO Series. LGM C T5 CLEAR GLASS LED MODULE Rev1.1 Specification (0)

FLYYO Series. LGM C T5 CLEAR GLASS LED MODULE Rev1.1 Specification (0) FLYYO Series LGM-1200-4000-C T5 CLEAR GLASS LED MODULE Rev1.1 Specification www.gryyn.eu info@gryyn.eu +49 (0)40 589 744-0 CONTENT 1. APPLICATION............................ Page 2. FUNDAMENTAL SPECIFICATIONS...........

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)

More information

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257

More information

simply providing that illuminance is not enough to ensure good quality lighting (SLL 2012)

simply providing that illuminance is not enough to ensure good quality lighting (SLL 2012) simply providing that illuminance is not enough to ensure good quality lighting (SLL 2012) Light is the visible part of the electromagnetic spectrum The main source of our natural light is the sun, which

More information

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED Lighting) Rm 1902, Easey Comm Bldg 253-261 Hennessy Rd Wanchai, HONG KONG LED Tube Light Model name(s): HC-T8-8FT-36W-ID(Clear) Representative

More information

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model: LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD Energy Star Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name:OKT Lighting) NO.2076 Jincheng Rd, Shajing Town, Bao an District,Shenzhen, China SSL downlight retrofits Model name(s):c10-d40w-30e

More information

Product family datasheet PARATHOM LED PIN G4 12 V

Product family datasheet PARATHOM LED PIN G4 12 V PARATHOM LED PIN G4 12 V Low-voltage 12 V LED lamps with retrofit pin base G4 Areas of application _ Atmospheric accent lighting throughout the home _ Shops, hotels and restaurants _ Foyers, offices _

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:

More information

PRODUCT FAMILY DATASHEET PARATHOM Retrofit CLASSIC A

PRODUCT FAMILY DATASHEET PARATHOM Retrofit CLASSIC A PARATHOM Retrofit CLASSIC A LED lamps, classic bulb shape AREAS OF APPLICATION Perfect for decorative installations Domestic applications General illumination Outdoor applications only in suitable luminaires

More information

PARATHOM advanced CLASSIC A

PARATHOM advanced CLASSIC A PARATHOM advanced CLASSIC A Dimmable LED lamps, classic bulb shape Areas of application _ Domestic applications _ General illumination _ Outdoor applications only in suitable luminaires Product benefits

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson

More information

PARATHOM PAR ADV 4.8 W/840 GU10

PARATHOM PAR ADV 4.8 W/840 GU10 PARATHOM PAR16 35 36 ADV 4.8 W/840 GU10 PARATHOM PAR16 advanced Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application Spotlighting for accents Display cabinets and shop windows

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light

More information

IESNA standards on LED and SSL: LM-79, LM-80, and future standards

IESNA standards on LED and SSL: LM-79, LM-80, and future standards CORM 2009 Conference, Gaithersburg, MD, May 6-8, 2009 IESNA standards on LED and SSL: LM-79, LM-80, and future standards Yoshi Ohno Director of CIE Division 2 Member of ANSI C78-09, IESNA TPC National

More information

Negative ion Lamp GTFL-13 by GreenTubes

Negative ion Lamp GTFL-13 by GreenTubes Negative ion Lamp GTFL-13 by GreenTubes Page 1 of 22 Summary measurement data parameter meas. result remark Color 2783 K warm white temperature Luminous 55.3 Cd Measured straight underneath the lamp. intensity

More information

LED LIGHTING GUIDE. We will help you find the right light bulb!

LED LIGHTING GUIDE. We will help you find the right light bulb! LED LIGHTING GUIDE We will help you find the right light bulb! THE RIGHT LIGHT SOURCE FOR YOUR NEEDS Decorative lighting With this light bulb the most important thing is what it looks like not how it illuminates

More information

Cat# LED Wall-PACK

Cat# LED Wall-PACK Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle

More information

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)

More information

PARATHOM Retrofit CLASSIC A DIM

PARATHOM Retrofit CLASSIC A DIM PARATHOM Retrofit CLASSIC A DIM Dimmable LED lamps, classic bulb shape Areas of application _ Perfect for decorative installations _ Domestic applications _ General illumination _ Outdoor applications

More information

Eternal Shine Technology Co.,Ltd. EST

Eternal Shine Technology Co.,Ltd. EST Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine

More information

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE) LM-79-08 Test Report For Torshare Ltd. (Brand Name: TORSHARE) 5th Minying Road No.3 Industrial Area Shuitian Shiyan Town Bao'an District,Shenzhen Guangdong 518108 China Direct Linear Ambient Luminaires

More information

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG 57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard

More information

LED STAR PAR16. Product family datasheet. LED reflector lamps PAR16 with retrofit pin base

LED STAR PAR16. Product family datasheet. LED reflector lamps PAR16 with retrofit pin base LED STAR PAR1 LED reflector lamps PAR1 with retrofit pin base Areas of application _ Spotlighting for accents _ Domestic applications _ Spotlighting heat-sensitive objects such as food, plants, etc. _

More information

PARATHOM PAR ADV 5.3 W/840 GU10

PARATHOM PAR ADV 5.3 W/840 GU10 PARATHOM PAR16 50 36 ADV 5.3 W/840 GU10 PARATHOM PAR16 advanced Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows

More information

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014 IESNA LM-79: 2008 Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE Dec 08, 2014 Product Name: LED Model No: 82031 Test Engineer: David Zhang Report No.: BTR66.181.14.0039.06

More information

RF Exposure Evaluation Report

RF Exposure Evaluation Report 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Report No.: SHEM151100411103 Page: 1 of 8 1 Cover Page RF Exposure Evaluation

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Product Overview. Key Features. (ship.unit) 5,9 W 2700 K 350 GU mm 50. mm 60 g

Product Overview. Key Features. (ship.unit) 5,9 W 2700 K 350 GU mm 50. mm 60 g Product Overview Product Wattage CCT lm Base LED SUPERSTAR MR16 35 36 827 LED SUPERSTAR MR16 35 36 840 5,9 2700 350 GU5.3 5,9 4000 350 GU5.3 Benefits For all household luminaires Low energy consumption

More information

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &

More information

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Accent Lighting Directional lighting to emphasize a particular object or draw attention to a display

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative

More information

1200 x 300 mm led panel by ElektoLED

1200 x 300 mm led panel by ElektoLED 1200 x 300 mm led panel by ElektoLED Page 1 of 23 Summary measurement data parameter meas. result remark Color 5039 K neutral white temperature Luminous 761.3 Cd Measured straight underneath the lamp.

More information

PARATHOM PAR W/827

PARATHOM PAR W/827 PARATHOM PAR16 PARATHOM PAR16 LED reflector lamps PAR16 with retrofit pin base Areas of application Spotlighting for accents Display cabinets and shop windows Retail outlets and exhibition rooms Spotlighting

More information

CLARA ED FELICIA ED 4W

CLARA ED FELICIA ED 4W CLARA ED FELICIA ED 4W Page 2 of 24 This LED module is designed for external driver and is therefore very easy to mount and connect in applications normally made for Halogen with external wall outlet transformer.

More information

Fluorescent lamp Spectralux Plus NL-T8 58W/840/G13

Fluorescent lamp Spectralux Plus NL-T8 58W/840/G13 Product Datasheet Date: 23/12/2016 Fluorescent lamp Spectralux Plus NL-T8 58W/840/G13 Logistic Data Article No. 31109322 Code NL-T8 58W/840/G13 Product EAN 4008597093227 Customs tariff no. 85393110 Box

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:

More information

LED: Light Emitting Diodes FACTS GUIDE

LED: Light Emitting Diodes FACTS GUIDE LED: Light Emitting Diodes FACTS GUIDE A.D.COLA LIGHTING 86 Worcester St. Natick MA 800-698-LITE www.adcola.com 2 Photo Courtesy of Feiss Lighting your home efficiently is continually becoming more popular.

More information

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures.

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures. LINGO n. pl. ling goh. (Informal) The specialized vocabulary of a particular field or discipline. The language and speech, esp. the jargon, slang, or argot, of a particular field, group, or individual:

More information

71332 LED Dusk To Dawn (Area Light)

71332 LED Dusk To Dawn (Area Light) 71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted

More information

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498

More information

LM Test. for LED. Cabinet

LM Test. for LED. Cabinet LM-79-08 Test Report for ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China 5190855 LED Cabinet Light Model: 535021## #(##=11-30)

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

More information

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary Test Summary Model MT8N28 Luminous Efficacy (Lumens /Watt) 101.5 Total Luminous Flux (Lumens) 1860.0 Power (Watts)/2 18.32 Power Factor 0.9972 CCT (K) 3948 CRI 82.9 Stabilization Time (Light & Power) 60

More information

SubstiTUBE Basic. Product family datasheet. Tubular LED lamps

SubstiTUBE Basic. Product family datasheet. Tubular LED lamps SubstiTUBE Basic Tubular LED lamps Areas of application _ Cooling and storage rooms _ Corridors, stairways, parking garages _ Ideal for simple lighting tasks Product benefits _ Quick, simple and safe replacement

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received

More information

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: ee.guangzhou@sgs.com Page:

More information

Product Overview. Key Features. 3,7 W 4000 K 220 GU mmm 50 mm 35 g

Product Overview. Key Features. 3,7 W 4000 K 220 GU mmm 50 mm 35 g 24 /36 advanced Product Overview Product Wattage CCT lm Base 24 827 3,7 2700 210 GU5.3 36 827 3,7 2700 210 GU5.3 36 830 3,7 3000 210 GU5.3 36 840 3,7 4000 220 GU5.3 Benefits For all household luminaires

More information

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K)

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K) LED BUYER S GUIDE Save energy, time and money with the right LED purchase LED technology has rapidly evolved in the past seven years and is now quickly gaining popularity in the household, representing

More information

Light calculation example

Light calculation example Lighting Basics Light calculation example Lumen Candela Lux Luminous flux (Lumen-1m) is the entire light output emitted by one lamp regardless of the direction. Luminous intensity (Candela-cd) is the part

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Fuel Pump Canopy Luminaires Model name(s): TLCLB80XYYZZ

More information

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

FCC MPE REPORT. Equipment Under Test (EUT): NOTE: The following sample(s) submitted was/were identified on behalf of the client as

FCC MPE REPORT. Equipment Under Test (EUT): NOTE: The following sample(s) submitted was/were identified on behalf of the client as 588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 8 1 Cover Page FCC MPE REPORT Application No.: Applicant:

More information

7 YEAR VALTAVALO G4 LED TUBES. valtavalo WARRANTY ADDITIONAL TECHNICAL DATA SHEET FOR G4 LED TUBES

7 YEAR VALTAVALO G4 LED TUBES. valtavalo WARRANTY ADDITIONAL TECHNICAL DATA SHEET FOR G4 LED TUBES VALTAVALO G4 LED TUBES ADDITIONAL TECHNICAL DATA SHEET FOR G4 LED TUBES 7 YEAR WARRANTY Quick, simple and safe replacement of T8 fluorescent tubes 125,000 hrs lifetime A 7-year warranty Manufactured in

More information

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting by Prof Wilhelm Leuschner and Lynette van der Westhuizen Energy efficiency and saving electrical energy

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate

More information