AGH Journal of Mining and Geoengineering Vol. 36 No ) and the area of the shaft (A b

Similar documents
Integrity testing of a very large number of piles

EXPERIENCES OF HIGH STRAIN DYNAMICS PILE TESTING (HSDPT) IN ACCORDANCE WITH EC7 IN SWEDEN

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

Module 5 : Design of Deep Foundations. Lecture 20 : Introduction [ Section 20.1 : Introduction ]

transmit foundation loads

Manual. Pile Design [NEN method]

Experimental Study on Pile Groups Settlement and Efficiency in Cohesionless Soil

A well planned and executed geotechnical ground investigation allows e management of engineering, health and safety and nancial issues.

Construction of Drilled Displacement and Auger Cast In Place Piles

Bearing capacity testing of pre-cast driven-in piles

Numerical Analysis of Piled Raft Foundation using Fem with Interaction Effects

Double rotary drilling

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

European Technical Assessment ETA 15/0029 of 12/06/2017

VIBRATIONAL TESTING OF A FULL-SCALE PILE GROUP IN SOFT CLAY

Piles Capacity Reference Manual

Module 6 : Design of Retaining Structures. Lecture 30 : Dewatering [ Section 30.1 : Introduction ]

Mounting of poles and foundations Rette produkt Til rette opgave

STABILITY. SECURITY. INTEGRITY.

Piled raft foundation for the W-TOWER Tel Aviv

Settlement Analysis of Piled Raft System in Soft Stratified Soils

ANALYSIS OF PILE-RAFT FOUNDATIONS NON- RESTED AND DIRECTLY RESTED ON SOIL

SKIN FRICTION OF PILES COATED WITH BITUMINOUS COATS Makarand G. Khare 1 and Shailesh R. Gandhi 2

Sixth Cycle Celebration of His Majesty the King of Thailand and 40 th Anniversary of the Asian Institute of Technology

DEEP FOUNDATION TYPES DESIGN AND CONSTRUCTION ISSUES

METHODOLOGY TO DEMONSTRATE PILE CAPACITY IN RELAXING GROUND

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

BENEFITS HAND-OPERATED BAILER BORING EQUIPMENT P SA Hand operated bailer boring set

SImulation of MONopile installation - JIP SIMON

With time, the evolution of anchors have led to different designs More than one anchor type may be suitable for a particular purpose Thus there are

NALYSIS OF STABILIZING SLOPES USING VERTICAL PILES

Comparison of the Behavior for Free Standing Pile Group and Piles of Piled Raft

System FS Duo Mounting Instruction. 1 General 2. 2 Pile driving 3. 3 Mounting the individual assembly groups 4. 4 Torque specifications 7

Module 9 Lecture 35 to 40 DRILLED-SHAFT AND CAISSON FOUNDATIONS

Advanced Ground Investigation Techniques to Help Limit Risk or Examine Failure. Advanced Subsurface Investigations

Limit Equilibrium including Shear Capacity for Launched Soil Nails. Matthew Birchmier, P.E.

GPR SURVEY METHOD. Ground probing radar

Correction for CPT f s errors due to variation in sleeve diameter

Numerical simulation of screw piles under axial loads in a cohesive soil

System FS Uno Mounting Instruction. 1 General 2. 2 Pile driving 3. 3 Mounting the individual assembly groups 4. 4 Torque specifications 6

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016

DEEP FOUNDATIONS PILES

Some Innovations for Offshore and Harbor Berths Construction

Performance of Piled Raft Foundation on Sand Bed

Geopier Foundation Company, Inc.

Module 10 : Improvement of rock mass responses. Content

Helical Pier Frequently Asked Questions

Soils for civil engineering purposes

Digital Data. Its use in geotechnical design & execution. Remedy Geotechnics Ltd. Dr Derek Egan Director.

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification

GEM-P Progress Report Mechanics (July 2006)

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

This document is a preview generated by EVS

4) Drive Mechanisms. Techno_Isel H830 Catalog

Advancement simulation of parallel tunnels and their interchange with two other subway lines using a new FEM approach, a case study

GSI System Designer s Guide

DETECTION LIMITS OF INTEGRITY TESTING. A.J.G. Schellingerhout and T.K. Muller IFCO BV Limaweg CB Waddinxveen The Netherlands.

Balancing Bandwidth and Bytes: Managing storage and transmission across a datacast network

SURFACE LAYER PROPERTIES IN DRY TURNING OF C45 STEEL

ABSTRACT INTRODUCTION. Immediate Displacement of the Seabed During Subsea Rock Installation (SRI) 3

CONTROL OF THE PROCESS OF SCREWING IN THE INDUSTRIAL SCREWDRIVERS

The DFI Institute is organized to serve as a primary means through which members of the Institute may participate in improvement of the planning,

An acousto-electromagnetic sensor for locating land mines

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Extract 8.7 When dimensioning an acute angle the tangential lines shown in Figure 4 shall be used. (C) Figure 4 - Dimensioning of an acute angle

DETERMINATION OF JOINT DIAGRAMS FOR A FOUNDATION BOLTED JOINT WITH THE BOLT ANCHORED IN A POLYMER PLASTIC

Nomograms for calculating the safety factor of homogeneous earth dams in long-term stability

ArcelorMittal Sheet Piling. Rock Bolts Horizontal toe support for steel sheet piles on bedrock

3. Existing uncertainties

ScienceDirect. Stabilization of Clay with Waste Soda Lime Glass Powder

SEA SELF DRILLING, THREADED, HOLLOW BAR / GROUT-ABLE SOIL NAILS / ANCHORS

DENTAL IMPLANT NUMERICAL MODELING USING PILE MODLEING SCHEME IN CIVIL ENGINEERING FIELD

KINAX 2W2 Programmable Transmitter for Angular Position

Prediction of Compaction Parameters of Soils using Artificial Neural Network

GEOLOGICAL INVESTIGATIONS

& 1 2 ) CEMSTAND... 4 CFA-LC 4 CFA-PL (CFA 5 CFA-TC (CFA

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

HELICAL PIPE PILES FOR LOADS UP TO 500 TONS

1. Random nature as to polarity, in that the pulse is sometimes positive and sometimes negative with respect to ground.

queensgate a brand of Elektron Technology

INDEX PAGE RELEASE SECTION NUMBER DATE

Practices and Challenges. For Open Pit Geotechnical Characterization, Design and Execution

EFFECTS OF INTERPOLATION TYPE ON THE FEED-RATE CHARACTERISTIC OF MACHINING ON A REAL CNC MACHINE TOOL

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

A COMPARISON BETWEEN ASTM E588 AND SEP 1927 RELATING RESOLUTION LIMITS AT DETERMINATION OF THE PURITY GRADE

FB-PIER VALIDATION SET

Monopile as Part of Aeroelastic Wind Turbine Simulation Code

Reinforcement with Soil Nails

Information Systems and Artificial Intelligence Technology Applied in Pile Design

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

D I A M O N D P U L S E - T E C H

75) Inventor: Charles L. Truman, Hendersonville, N.C. 57 ABSTRACT

British Columbia Carpenter Apprenticeship Program

Instrumentation to Monitor Bridge Foundation on the Crosstown Project

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

Model Correlation of Dynamic Non-linear Bearing Behavior in a Generator

Optimum Geometry of Monopiles With Respect to the Geotechnical Design

Journal of American Science 2015;11(8) Soil Nailing For Radial Reinforcement of NATM Tunnels

DESIGN EQUATION FOR MULTIPLE- FASTENER WOOD CONNECTIONS

Transcription:

AGH Journal of Mining and Geoengineering Vol. 36 No. 2 2012 ukasz Orabczuk *, Irena Bagi ska * THE ANALYSIS OF ESTIMATION THE PILE BEARING CAPACITY ON THE CPTU 1. Introduction The development of new CPTU subsoil testing techniques has not only contributed to the precise recognition of geotechnical parameters, but also to the creation of methods for estimating piles bearing capacity. The characteristic values of soil resistance under an impacted cone (q c ) and soil friction resistance on the shaft of the probe s sleeve (f s ) are directly applied to calculation algorithms. Unit resistance to the base of the pile and the pile s shaft are successively determined. This approach helps accelerate the process of pile design and it allows for the omission of interpretation of the CPTU tests. Several methods for estimating compressive pile bearing capacity on the basis of static probe CPTU ndings are presented in this paper. These methods have been divided into four groups based on their usefulness in the design process for particular pile construction techniques. All of the calculations refer to the universal method of Eurocode 7. The methods that ful ll the estimation of characteristic pile bearing capacity on the basis of subsoil CPTU tests rely on the same assumption and use the same formula (1): n Rck= Rbk, + Rsk, = Ab$ qbk, + / As$ qskj,, (1) i = 1 The characteristic compressive resistance of the ground against a pile (1) is the sum of the characteristic values of the base resistance and of shaft resistance with respect to the base area under the pile (A b ) and the area of the shaft (A b ). Their values are established on the basis of the characteristic values of the base resistance pressure (q b,k ) in accordance with (2) and the characteristic values of shaft friction in the subsequent strata (q s,k,j ) in accordance with (3). * Wroc aw University of Technology, Faculty of Civil Engineering, Wroc aw 247

q q q bk, skj,, skj,, = } 1 $ qr q = r sci } 2 f = r si } 3 c (2) (3) Base and shaft resistance factors 1, 2, 3 are chosen according to the calculation method used for determining the pile bearing capacity. Their values depend on the technology of the pile manufacture, soil type and condition and also on the method of averaging the values q c, q, f. csi si The average unitary soil resistance under the probe s cone ) in the pile s base area (q c is determined in accordance with (4), however the average unitary soil resistance under the probe s cone ) is based on qc measurement from equation (5), and the average unitary (q csi soil resistance to the probe s shaft friction ) is based on fs measurement according to (6). (f si qr c = 1 l1 + l2 h - h+ l2 # l1 qc^hhdh (4) qr csi = fr si = 1 Dh 1 Dh hi-1 hi-1 hi # hi # qc^hhdh fs ^hhdh (5) (6) Notation of formula (4, 5, 6) are consistent with Figure 1. Analytical calculations were performed on the actual soil conditions on site at the planned foundation of a structure. Figure 2 shows the measurement of cone resistance (q c ), sleeve friction (f s ), penetration pore pressure (u 2 ) and the designated geological pro le according to standard PN-B-04 452 classi cation [3] which were recorded while testing with a static probe. Hard-plastic cohesive soil in the form of clays and silty clays occured to the depth of about 5 m. Loose condensed hydrated and highly condensed soil in the form of medium sand and gravely sand performered below. 2. Methods of estimation of pile bearing capacity A division of methods for an estimation of the pile capacity has been created by dividing piles into four main groups characterized by different manufacture technology, and 248

Fig. 1. The notation used for the calculation of the bearing capacity of a single pile is on the basis of the CPTU tests Fig. 2. Pro le of static CPTU probing with interpretation 249

consequently with their different ways of working in the soil. This division is essential in order to choose the appropriate calculation criteria imposed by speci c design methods (Table 1). This procedure allows one to choose the appropriate load factors 1, 2, 3 depending on the type of technology. TABLE 1 Division of piles according to manufacturing technology and methods of calculating pile bearing capacity Displacement piles Patial displacement piles Drilled piles Division of piles according to manufacturing technology Driven or vibrated piles: Prefabricated reinforced concrete plies, Steel piles Piles made in soil: Vibro-Fundex, Vibrex, Fundex Piles, Frank Piles Piles made without shield pipe: Omega I CG Omega Piles, SDP Bauer BG Piles, de Wall Piles, Tubex Piles CFA Piles: Starsol, PCS Lambda, Soilex Drilled large diameter piles: Piles drilled without shield pipe, Piles drilled in concrete suspension, Piles drilled in a shield pipe vibrated-in, Piles drilled in a shield pipe, Piles drilled with an injection under the base and on the shaft Pile bearing capacity calculation methods Eurokod 7 Method Philipponant, K os Method Wi un Method Gianeselle, Bustamante Method Energopol Method Eurokod 7 Method Philipponant, K os Method Wi un Method Gianeselle, Bustamante Method Energopol Method Eurokod 7 Method Philipponant, K os Method Wi un Method Gianeselle, Bustamante Method Energopol Method Eurokod 7 Method Adamczyk Method Energopol Method Gwizda a Method Philipponant, K os Method Wi un Method Gianeselle, Bustamante Method 2.1. Adamczyk Method [1, 6] The Adamczyk method is effective in designing large-diameter piles constructed mainly in non-cohesive soils. Since they are large-diameter piles constructed in a shield pipe with its subsequent extraction, or more seldom, without a shield pipe, looseness of the soil at the shaft surface results. As a result, the load transfer of this kind of pile by the shaft is not taken into account when determining the bearing capacity of the element and it is assumed that the load is carried entirely by the base of the foundation. This method is rarely selected due to its limited use, but it gives a relatively high value in terms of the load capacity of the foundation, in comparison to alternative methods. 250

2.2. Gwizda a Method [1] This method, like the previous one, is recommended for use with large diameter elements. A numerical analysis of the bearing capacity can only be carried out when the pile is based on low-density soil like sand or gravel. In contrast to the Adamczyk method, it is recommended that not only the bearing capacity carried by the base of the foundation be considered, but also the bearing capacity of the pile shaft. 2.3. Energopol Method [1, 6] This method assumes the presence of two characteristic groups of piles, for which numerical analysis is carried out using different selected safety factors 1 and 2. The rst group comprises of piles with a diameter or diagonal cross-section of up to 0,60 m. The second group includes large diameter piles with diameters in the range 0,60 1,20 m. This method does not specify the piles manufacture technology and allows for carrying out calculations on soils such as sand and clay. However, there are no contraindications to using this method with gravel and gravel sand, and in the case of mixed soil the values of both factors can be interpolated. 2.4. Gianeselle, Bustamante Method [1, 6] This method has a wide range of possibilities. The factors are chosen individually depending on the soil and pile manufacturing technology. The average resistance of the cone static probe is determined in three stages. 1) The preliminary correction of q c obtained from CPTU tests, which means that the curve q c (z) (where z is the depth of the measurement), should be close to the minimum values of q c. 2) The determination of the average value of q c on the basis of the adjusted values of q c in the segment (z 1,5 D; z + 1,5 D) (where D is the pile diameter). 3) The determination of the average cone resistance under the CPTU probe in the area of the pile s base. It is one of the safest methods of design, because it is characterized by suitably large parameters of 1 and 2, and imposes the maximum values allowable for unitary shaft resistance, in the calculation. Higher values are rejected. 2.5. Wi un Method [6] The Wi un method for estimating single pile bearing capacity on the basis of an in-situ probe CPT can be used for all types of piles and soil. In this case, great precision is given to determining the factors of capacity, which makes it very time consuming. To determine the factors, a number of computational models and charts are used. 251

2.6. Philipponant, K os Method [2] This method requires that before calculating the bearing capacity, preliminary calculation must be performed according to particular formulas. Firstly, all the values that are signi cantly higher than from the average course of the graph q c must be eliminated from the graph q c, and the quali cation of these jumps depends exclusively on the engineer s interpretation. It is very possible that this procedure aims to eliminate the local inclusion of insigni- cant in uences on the pile s bearing capacity. This amendment eliminates local jumps of the q c plot and causes the estimated value of the bearing capacity have a higher safety stock. 1 and 2 factors are selected from the relevant tables depending on soil type and the pile manufacture technology. 2.7. Eurokod 7 Method [4] This is a method described in detail according to the new European standards, (Eurocode 7). These standards currently also apply in Poland and we are obliged to follow them. Certainly we can say that this method is the most detailed; it requires thorough analysis of resistance charts q c and f s and their partial transformations. All the other design methods mentioned above are based on an algorithm presented in Eurocode 7, however, they are its simpli cation and approximation. They don t investigate as thoroughly into the analysis of the strength of the pile foundation and they do not perform as many transformations and calculations. The biggest advantage of this method is that we work according to reliable standard recommendations. 3. The results of the estimation of the pressed pile bearing capacity Calculations were carried out in two different ways for all groups of piles with different manufacture technologies for the actual geotechnical conditions (Fig. 2). In the rst method, different diameters and lengths for the pile were assumed and a single pile bearing capacity was determined. The diameter was increased adapting to changing technology. In the second method, a certain capacity for the pile was assumed, and the length of the pile with which it was achieved was determined. 3.1. Driven or vibrated-in piles Five methods were used for estimating the bearing capacity of a pile with a diameter of 02 m and 0.4 m. Four of them were adapted to the manufacture technology of driven and vibrated-in piles, and one universal. The capacities were de ned with the assumption of three de ned pile foundation depths: 7.00 m, 11.00 m and 14.00 m (Fig. 3). For the depth of 7 m very similar results were obtained regardless of the design method. The deeper the depth of the foundation was assumed to be, the greater the dispersion of capacity values obtained. 252

Fig. 3. Estimation of driven and vibrated-in pile s bearing capacity Assuming a pile bearing capacity of 1000 kn, a pile length needed to provide this capacity was calculated (Fig. 4). For piles with a diameter of 0.2 m a large spread for the pile length was obtained. The solution for piles with a diameter of 0.4 m is much more stable. Fig. 4. Estimation of driven or vibrated-in pile length The analysis showed that the Energopol method gave the lowest estimation in both, determining the capacity and also determining the length of a pile at a constant capacity. The greatest bearing capacity, which is the shortest length of the pile to obtain a speci ed bearing capacity comes from the standard Eurocode 7 method. 3.2. Piles constructed in soil with the removal of a shield pip Five methods were used for estimating the bearing capacity of a pile with a diameter of 0,4 m, while for the pile with a diameter of 0,6 m six methods were used. Four were adapted to the manufacture technology of piles constructed in soil with the removal of a shield pipe. The capacities were de ned on the assumption of three de ned pile foundation depths: 7.00 m, 11.00 m and 14.00 m (Fig.5). For piles 7 m the greatest bearing capacity was 253

determined by the Wi un method, and the smallest by the Gianeselle, Bustamante method. For the remaining lengths, the highest values of capacity were obtained using the Eurocode 7 method, and the lowest with the general Energopol method, regardless of the pile diameter. Fig. 5. The estimation of bearing capacity of piles constructed in soil with the removal of a shield pipe For a pile diameter of 0.6 m and length of 11 m a pile bearing capacity was additionally estimated with the classical method of withdrawn standards PN-83/B02482. This value is comparable to that obtained with the Wi un method, and it constitutes only 55% of the capacity obtained using standardized Eurocode 7 method. Assuming a pile bearing capacity of 2000 kn the wide spread necessary to render a pile s length was obtained with a diameter of 0.4 m, while for piles with a diameter of 0.6 m similar lengths were obtained (Fig. 6). Fig. 6. The estimation of the length of piles constructed in soil with the removal of a shield pipe 3.3. Piles constructed in soil without a shield pipe Five methods were used for estimating the bearing capacity of piles with a diameter of 0.6 and 0.8 m. Four methods are adapted to the manufacture the technology of piles constructed in 254

soil without a shield pipe. The capacities were de ned on the assumption of three de ned pile foundation depths: 7.00 m, 11.00 m and 14.00 m (Fig.7). For piles of 7 m the largest bearing capacity was determined using the Wi un method, and the smallest with the Energopol method. For the remaining lengths and the diameter of 0.6 m, the highest values for bearing capacity were obtained by the Wi un method, and the lowest with the general Energopol method. Different solutions were observed for piles with a diameter of 0.8 m, where the highest results came with the Eurocode 7 method, and the lowest ones from the Gianeselle, Bustamante method. Fig. 7. The estimation of bearing capacity of piles constructed in soil without a shield pipe Assuming the pile bearing capacity of 3000 kn, the spread of 45% necessary to calculate a pile s length with a diameter of 0.8 m was obtained, while for piles with a diameter of 0.6 m, lengths differ by 26%, in regard to the shortest of the piles (Fig. 8). Fig. 8. The estimation of the length of piles constructed in soil without a shield pipe The analysis showed that once again the lowest estimation came from the general Energopol method in determining a pile s capacity and in determining the length of the pile at a constant capacity. 255

3.4. Drilled large diameter piles Seven methods were used for estimating the bearing capacity of piles with a diameter of 1.0 and 1.2 m. The capacities were de ned with the assumption of three de ned pile foundation depths: 7.00 m, 11.00 m and 14.00 m (Fig. 9). For piles of 7 m, the highest bearing capacity was determined with the Wilun, Philipponante and Klos methods, and the smallest with the Gwizda a method. For the remaining lengths, the highest values of capacity were obtained using the Eurocode 7 method, and the lowest with the Gwizda a method, regardless of the pile diameter. Fig. 9. The estimation of the bearing capacity of large diameter piles Assuming a pile bearing capacity of 4000 kn, a spread of 22% is necessary to calculate a pile s length with a diameter of 1.0 m and was obtained, while for the piles with a diameter of 1.2 m, lengths differ by 30%, in regard to the shortest of the piles (Fig. 10). Fig. 10. The estimation of the length of large-diameter piles 256

4. Summary The differences in the results of the methods presented are primarily a consequence of the diverse manner of including the values for qc and fs recorded during static probe tests in the calculations. The value of the capacity factors ( 1, 2, 3 ), which depend on the type and condition of the soil and the technology used for the pile manufacture are also highly in uential. These values are imposed by each method and a speci c value or range is indicated. This leaves the designer with the opportunity of clarifying their values by using graphs or speci c functions. The value of these factors determines the precision of the design method, depending on whether it includes, in detail, the type of soil and the diversity of pile manufacture technologies. This affects the safety of the element being designed. The most important factors contributing directly to the estimation of the value of a bearing capacity are: the type of soil and its condition; diameter, depression and technology of the pile manufacture. It is on this basis, depending on the design method factors, that 1, 2 and 3 are determined. An equally important factor is the determination of the averaging range for calculating the values of q c and f s, and the length l 1 and l 2, which are multiples of the pile diameter. Among all of the design methods used to determine the pile bearing capacity and of all the pile manufacture technologies used, the highest values of bearing capacity at the assumed length of a pile in loose soil was gained using the Eurocode 7 method. The remaining methods are based on the former. It is the most complicated and complex in terms of bearing capacity estimation methods. The remaining methods, by comparison, contain some simpli- cations which are designed to simplify and streamline the entire design process. However, such procedures also lead to a reduction in the accuracy of the results obtained, and consequently higher factors of capacity are applied. Therefore the standard method gives greater strength than the others in the majority of the instances included in this work. The Energopol method allows for an approximate estimation of bearing capacity but of all the methods mentioned in this article, gives the smallest values. This is mainly due to the lack of classi cation in this method and for any speci c manufacture technology, which also has an impact on increasing the factors for 1 and 2, which nally gives greater headroom for the estimated values. The best (and recommended by an amendment to the Eurocode 7) method of pile bearing capacity design is load tests, from which a computational model factor is determined. Before carrying out probationary load tests, a designer should always decide on the type of piles and the piling technology to be used. Piles are designed, constructed and nally subjected to probationary load tests. Many factors affect this decision, among others, geotechnical, economic and technological conditions as well as the technical capabilities of building companies. The extensive analysis presented can provide information with a wide range of bearing capacity estimates using various methods. Designers can obtain information in order that the analytical design of pile bearing capacity can be worked out on the basis of CPTU tests and is worth carrying out using a number methods. 257

REFERENCES [1] Gwizda a K.: Fundamenty palowe. Technologie i obliczenia. Wydawnictwo Naukowe PWN, Warszawa 2010. [2] K os J.: Obliczanie no no ci pojedynczego pala na podstawie wyników sondowa statycznych. In ynieria Morska i Geotechnika, nr 3, 1983, s. 303 306. [3] PN-B-04452:2002 Geotechnika. Badania polowe [4] PN-EN 1997-2:2009: Eurokod 7: Projektowanie geotechniczne Cz 2: Rozpoznanie i badanie pod o a gruntowego. [5] PN-83/B-02482: Fundamenty budowlane. No no pali i fundamentów palowych. [6] Sikora Z.: Sondowanie statyczne metody i zastosowanie w geoin ynierii, Wydawnictwo Naukowo Techniczne, Warszawa 2006. [7] Wi un Z.: Zarys geotechniki. WK, Warszawa 1987.