INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

Similar documents
Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

International distributors

Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

Substation Preventive Maintenance

MD-5060 DIGITAL MEGOHMMETER

Insulation Testers and Earth Ground Testers

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

METREL Measuring and Regulation Equipment

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Motor Winding Ohmmeter RMO50M

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

MIT415 Insulation tester

Digital insulation tester

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Protection components

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

MIT400 CAT IV Industrial Insulation Testers

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

Testboy TV 416/432(A) CEE adapter*

ELECTRICAL TESTING AND SAFETY

M.8. Portable power analyzers and accessories CONTENTS. Page. Introduction 3 AR.5 AR5L. Power analyzers 4. Applications 4 Harmonics.

GAMMA 12 DIGITAL MULTIMETER

DM-45 Digital Multimeter

MIT400 CAT IV Industrial Insulation Testers

MI-10kV. Technical specifications Operating instructions. Supplier:

Automatic capacitor banks with detuned filters

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

1650 Series Multifunction Installation Testers

Eurotest 61557, Instaltest 61557

MIT400/2 CAT IV Insulation testers

Fluke and

SUBJECT TO CHANGE WITHOUT NOTICE

Automatic capacitor banks with detuned filters

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

RMO-A series Micro Ohmmeters

GSC57 Rel of 257/10/05

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

GROUND TESTERS For all of your Ground Testing needs...

Instruction Manual for Digital Grounding Resistance Meter

The NEW itig II Winding and Motor Analyzer A revolution in automated, safe, and comprehensive high and low voltage tests all in a lightweight

SECTION PAGE. SENSORLINK EQUIPMENT Ampstik Ampstik Plus Ohmstik & Qualstik Plus Radio Ampstik Troubleman s Kit & Voltstik Amcorder & Varcorder

Family 400 meters Rel /04/2007

PROFiTEST C Test Instrument per DIN VDE /11.10

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

TORKEL 900-series Battery Load Unit

Measurement and control. Digital instruments and measuring transducers

ANNEXURE 1 LIST OF EQUIPMENTS LOT 1

TORKEL 900-series Battery Load Unit

PROFiTEST C Test Instrument per DIN VDE /8.14

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

BM25 Automated 5-kV Insulation Tester

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

The first installation safety tester with automated testing based on patent pending AUTO SEQUENCE.

GAMMA 10 DIGITAL MULTIMETER

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Technical features table for miniature circuit-breakers SH 200 Series

MIT400 CAT IV Industrial Insulation Testers

79/26 Series III Multimeter

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Technical Data Sheet. Zeta 20

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

VI 3 - i TABLE OF CONTENTS

MIT400 CAT IV Industrial Insulation Testers

UTILITY & SUBSTATION TESTING

ISOMETER IRDH575. Approvals

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Licensed Electricians Practical Assessment (LEP)

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

MIT510/2, MIT520/2 and MIT1020/2

Protection relays and transformers

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

This portable DC ground fault locator provides a quick and cost-effective solution for ground fault locating in DC distribution systems.

DC Resistance Meters 2840 Series

OM 16. Onsite micro-ohmmeter up to 10 A

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Indeks: WMXXCMM60 Advanced Industrial Multimeter

GAMMA 20 DIGITAL MULTIMETER

Winding Ohmmeter & Tap Changer Test Set RMO10TW

Operating instructions Electronic level sensor LK / / 2008

Winding Ohmmeter RMO-TW

MIT480/2 Insulation testers

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

Method for Static and Dynamic Resistance Measurements of HV Circuit Breaker

Licensed Electricians Practical Assessment (LEP)

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Analog Digital Multimeter with Insulation Resistance Measurement

Smart Power Relay E I...

MIT400/2 CAT IV Insulation testers

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

27/04/2015

Transcription:

Micro-ohmmeter MH-10 Page 3 MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Earth resistance meter TL-5 Page 5 Indirect earth contact simulator MPC (5, 20, 50 A) Page 6 Trip time tester CR (50, 100, 250 A) Page 7 Dielectric strength tester OT-60 Page 8 Introduction INDEX In order to enter a company in the HVMCR, technical measures must be available which subsequently shall be used during maintenance for these installations. Below is a list of the minimum necessary technical requirements: Three-phase system analyzer-recorder with printer or internal memory. (Our AR.5L) Insulation measurer (Mega-ohmmeter) up to 5 kv Kelvin bridge (Micro-ohmmeter) Step and contact voltage measuring equipment Indirect earth contact simulator. (Earth resistance checker and ground resistivity checker) Portable dielectric rigidity checker for the insulating oil Direct and indirect relay checker case Ammeter clamp 5 kv A generating set Field thermometer with a measurement range of -10 C / +250 C detecting insulating pole Earth and short circuit equipment Pair of gloves and bench suitable for HV. Vacuum cleaner for cleaning stations Below is a list of equipment supplied by CIRCUTOR for transformation centre maintenance. P6-2

Power supply features Rechargeable sealed battery Built in charger Supplied from mains Protected by fuse Measurement features Resistance measurement ranges Resolution Test voltage Basic accuracy Display 12 V - 7 A h Yes Yes Schurter, SPT 5x20 (Time-lag) 5 A / 250 V a.c. High cut off capacity 0-2 000 µω 10 A 0-20 mω 10 A 0-200 mω 1 A 0-2 000 mω 100 ma 0-20 Ω 10 ma 0-200 Ω 1 ma 1 µω for 10 A Up to 10 V d.c. for 1 A to open circuit ± 0,2 % of the measured value ± 2 digits Alpha-numeric 4 ½ digits The digital MH-10 micro-ohmmeter is portable equipment controlled by microprocessor for highly accurate measurements of very low resistance circuit breaker contacts, keys, conductor bars transformer coils and motors, welded points, etc., with test currents from 1 ma to 10 A. The MH-10 micro-ohmmeter operates according to the terminal method (Kelvin bridge). In this way resistance from the injection cables themselves is avoided. The test current is selected by the operator and the read out is obtained by comparing it with highly stable internal master currents. The results are shown on an easy to read alpha-numeric screen. Communications Series data output RS-232 to 4.800 bps Dimensions 378 x 308 x 175 mm Weight 8,8 kg (including accessories) Protection index IP 54 with closed cover Environmental conditions Operating temperature - 5 ºC / + 50 ºC Storage temperature - 25 ºC / + 65 ºC Humidity Maximum operating altitude Standards Micro-ohmmeter MH-10 Type MH-10 Code P60711 95 % HRA (without condensation) 3 000 m above sea level IEC 61010-1/990, IEC 61010-1/992 amendment 2 IEC 61326-1 IEC 1000-4-2 Accessories included Combined test points (current and power) Carrying bag Supply cable RS-232 Cable P6-3

Mega-ohmmeter MI / MD System kv Type Code Analogue 5 MI-5500e P60511 Digital 5 MD-5060e P60521 Analogue 10 MI-10 kve P60512 MD and MI portable mega-ohmmeters have been specially designed to measure insulation resistances up to TΩ, using test currents selected by the user. Its highly reliable technology allows accurate measurements to be taken and easily read for low and medium voltage electrical system insulation, transformers, motors, cables, domestic equipment and installations, distribution systems, etc. They include a rechargeable internal battery and may be supplied from the electrical system. It is ideal for use in fi eld work: being protected against severe handling conditions which inevitably includes frequent knocks, very high and low temperatures, strong vibrations during transport on bad roads, prolonged exposure to direct solar radiation, etc. System kv Type Code Analogue 15 MI-15 kve P60513 Analogue 20 MI-20 kve P60514 MD-5060e (*) MI-5500e MI-10 kve MI-15 kve MI-20 kve Technology Electronic Analogue Power supply features Rechargeable battery 12 V - 2,3 A h 12 V - 7 A h Battery charger 18 V - 1,2 A 220-240 V a.c. Short circuit current 1,5 ma (± 0,5 ma) 1 ma 500 µa Measurement features Scope 5 000 000 MΩ / 5 kv 10 000 000 MΩ 2 000 000 MΩ 3 000 000 MΩ 4 000 000 MΩ Test voltage 0,5-1 - 1,5-2 - 2,5-3 - 3,5-4 - 4,5-5 kv 0,5-1 - 2,5-5 kv 1-2 - 5-10 kv 1-5 -10-15 kv 5-10 - 15-20 kv Scale change Automatic Manual Basic accuracy 5 % of the reading ± 3 digits Class 1 Class 2 (± 2 % of the deflection at the end of the scale) Indicator LCD + analogue bars Analogue Recording memory Yes No Communications Series data output RS-232 to 4.800 bps Not available Printer Optional (PR-01) Not available Environmental conditions Operating temperature - 5 ºC / + 50 ºC - 5 ºC / + 50 ºC Storage temperature - 25 ºC / + 65 ºC Humidity 95 % (without condensation) Maximum operating altitude 3 000 m above sea level Dimensions 274 x 250 x 124 mm 378 x 308 x 175 mm Weight 3 kg 4,1 kg 9,5 kg 9,7 kg 9,8 kg Protection index IP 54 (With cover closed) Standards IEC 61010-1/1990, IEC 61010 1/1992 appendix 2, IEC 61326-1, IEC 61000-4-3, IEC 61000-4-2 (*) Includes advanced features such as: automatic calculation of polarization and dielectric absorption index, fixed time step / non step tests and built in digital chronometer P6-4

Earth resistance meter TL-5 The TL-5 earth resistance meter is a digital equipment controlled by a microprocessor and designed to measure earth resistances and resistivity (using the Wenner method). It can also detect parasite voltages in the ground. It is therefore ideal equipment for measurements in electrical substations, industrial settings, distribution systems, etc., under the IEC 61557-5 Standard. The TL-5 is totally automatic and very easy to use. Before starting to measure, the equipment checks if the installation is within the appropriate limits and will notify the user if there is any anomaly (interference voltages too high, very low test current, etc). It also has a memory capable of storing up to 4 000 recordings. Type TL-5 earth resistamce meter Printer (PR-01) Code P60621 P69911 Power supply features Communications Rechargeable battery 12V - 2,3 A h Series output RS-232 Battery charger 95-240 V a.c. 50...60 Hz Printer Optional Short circuit current < 3,5 ma Environmental conditions Measurement circuit Operating temperature -10 ο C / +50 ο C Resistance 0-20 kω Storage temperature -25 ο C / +65 ο C Resistivity 0-50 kω Humidity 95 % (without condensation) 0-60 V a.c. Maximum operating altitude 3 000 m Accuracy Resolution and Resistivity Reading resolution Resistance ±2 % of the measured value ±2 digits ±3 % of the measured value ±2 digits 0,01 Ω Dimensions Weight Protection index Standards 274 x 250 x 124 mm 3 kg IP 54 (with cover closed) IEC 61010-1/1990, IEC 61010, 1/1992 appendix 2, IEC 61326-1, IEC 1000-4-2, IEC 61000-4-3 Resistivity 0,01 Ωm 0,1 V Accessories Included 5 A Printer (Optional) P69911 4 Probes 1 40 cm red cable 2 20m green and blue cables 1 5 m black cable 1 Cable 5 m cable to connect to earth measurement system Probe case Battery charger with 95-240 V a.c. power supply source. P6-5

Indirect earth contact simulator MPC Fig.2 Fig.1 Fig.3 A Type Code Figure 5 MPC-5 P60111 Fig.1 20 MPC-20 P60112 Fig.2 50 MPC-50 P60113 Fig.2 MPC-5, MPC-20 and MPC-50 simulators allow voltages appearing between points in the ground to be measured (step voltages) or can measure voltages between earth and conducting parts (contact voltage) when there are leakages through the earth. Simulators have an alternating current source which is injected between two points on an earth to simulate a leakage current. They also have an electronic voltmeter which measures the voltage drops caused by this current. The MPC-5 may inject up to 5 A, the MPC-20 up to 20 A and the MPC-50 up to 50 A. In order to carry out the test, the current source is connected between distant points on an earth line and the voltage between two weights one meter apart is measured by a voltmeter (step voltage) or the voltage between two weight one meter apart (step voltage) or between earth and accessible conducting parts is measured. The current source may be set at the required level. The measurer, controlled by a microprocessor, carries out the measurement using a standard current and can calculate the step and contact voltage for any other preset current. Earth resistance between two points may also be measured. The results are memorized and shown on an LCD display. ACCESSORIES FOR CR-250 Trolley for P69901 CR-250 / MPC-5 Fig.3 MPC-5 + test weights + measurement cables + auxiliary earth rods MPC-20 + test weights + measurement cables + auxiliary earth rods + trolley MPC-50 + test weights + measurement cables + auxiliary earth rods + trolley Electrical features Power supply voltage 230 V a.c. 230 / 400 V a.c. tolerance +10 % / -15 % Consumption current 15 A 60 A 97 A / 57 A Frequency 50...60 Hz Measurement Maximum injected voltage 500 V 600 V 400 V Digital voltmeter scales 500 V and 10 V Input impedance 300 kω / 1 kω Digital ammeter scale 99,9 A Analogue ammeter --- 20 A 50 A Maximum earth resistance (including auxiliary earth socket) 100 Ω 8 Ω 8 Ω Accuracy 1 % of the reading / ± 2 digits Current 1 % of the reading / ± 2 digits Resistance 3 % of the reading / ± 2 digits (0...25 Ω) (current supply cables not included) Mechanical features Equipment size 280 x 470 x 500 mm 450 x 870 x 600 mm (with trolley) Equipment weight 42 kg 120 kg 120 kg Accessories weight 12 kg Test weight dimensions 170 x 300 mm Test weight 2 x 25,5 kg Standards (MIE-RAT-13), IEC 348, IEC 664, UNE 20 553, VDE 0110 P6-6

Trip time tester CR Fig.1 Fig.3 Fig.2 CR-50, CR-100 and CR-250 equipment is made up of current sources especially designed to check the current / time trip curve for automatic switches and indirect protection relays. They operate on the principle of injecting an adjustable alternating current into the circuit being tested via a cable loop in short circuit. Connecting an auxiliary contact to the switch being tested allows the trip time to be measured for each current selected. The test is very easily carried out using a stop-start command. An automatic measuring system carries out the measurements and shows them on the display. It is worth highlighting that the whole protection system may be checked, including the current transformer in the case of indirect relays, because the current may be injected on their primary side. After the test the digital display automatically shows the size of the injected current and the trip time. These are displayed until the RESET is pressed. A Type Code Figure 50 CR-50 P60211 Fig.1 100 CR-100 P60212 Fig.2 250 CR-250 P60213 Fig.3 CR-50 CR-100 CR-250 Electrical features Power supply voltage 230 V a.c. (+10 % / -15 %) Frequency 50...60 Hz Current supply Insulated, short circuitable, adjustable from front control Overload capacity 1,5 I n, 1 min (12 V max.) 2,5 I n, 10 s (6 V max.) / 1,5 I n, 1 min (12 V max.) Nominal power 300 V A 600 V A 2 500 V A Current 1,6 A max 6 A max 20 A max Current supply 0 to 6 V : I n = 50 A max 0 to 30 V : I n = 10 A max 0 to 6 V : I n = 100 A max 0 to 30 V : I n = 20 A max Measurement Current measurement Digital equipment Accuracy 1 % of the reading / ± 2 digits 0.5 % of the reading / ± 1 digit Time measurement Digital clock Measurement fi eld Up to 99 999.9 s Up to 9 999.99 s Test method start Automatic stop Manual stop With start button Aux. contact open or closed With stop button 10 to 50 V : I n = 50 A max 0 to 10 V : I n = 250 A max Mechanical features Weight 11 kg 22 kg 43 kg Dimensiions 320 x 200 215 mm 430 x 312 x265 mm 280 x 470 x 500 mm Standards IEC 348, IEC 664, UNE 20 553, VDE 0110 *see also regulations on determining test methods Accessories Trolley P69901 Cable 2 500 A P69902 Transformer 2 500 A P69903 P6-7

Electrical features Power supply voltage 230 V a.c. (+10 % / -15 %) Frequency 50...60 Hz Consumption 100 V A / 1200 V A point Equipment operating temperature 0 ºC / +50 ºC Test circuit Maximum voltage 60 kv a.c. Accuracy ± 2 % Frequency 50 Hz ± 2 % ramp (selectable) 5, 3, 2 or 0,5 kv / s Disconnection time on producing the arch < 20 ms Agitation time 60 s (preset) Standby time before test 60 s (preset) Equipment operating temperature + 15 ºC / +25 ºC measurement With digital voltmeter Dimensions 385 x 300 x 400 mm Weight 38 kg Test cell Methacrylate Useful capacity of cell 480 ml Electrodes Stainless steel Oil agitator TEFLON (P.T.F.E.), included Light Fluorescent lighting the test chamber Insulating oil 60 kv Standards *preset test standards in each piece of equipment UNE 21 309, IEC 156, DIN VDE 0370 (p5), UTE C-27221 On request, test electrodes for ASTM 877, ASTM 1816, etc. standards may be supplied Dielectric strength tester for insulating oil OT This equipment has been especially designed to determine the dielectric strength of any type of insulating oil used in transformers, industrial cables, automatic switches and new or old capacitors. Controlled by microprocessor, their memory includes parameters set by the different standards to carry out these tests. Simply by pressing the corresponding command for the selected Standard, the microprocessor sets the test in accordance with the conditions set by that Standard. Type OT-60 Code P60311 P6-8