The Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010

Similar documents
APPENDIX V PRODUCT SHEETS

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

CP /240-MC4 User Manual

SOLON Corporation Potential Induced Degradation

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

How to Evaluate PV Project Energy Yield

Understanding Potential Induced Degradation for LG NeON Model

Quality criteria and certificates

SOLARLOK PV BAR Junction Box

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

The Standard for over 40 Years

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

Upsolar Smart Modules

Photovoltaic Glass Technologies

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

OEM pressure transmitter For mobile working machines Model MH-3

ELECTRICAL AND THERMAL MODELING OF JUNCTION BOXES

Optimized for perfection.

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

Building a Solar PV Roadmap The National Academies July 29, Ken Zweibel GW Solar Institute The George Washington University

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

Voltage Sag Immunity Compliance Certificate PULS QS10.241, QS A1, QS C1

Accelerating Growth and Cost Reduction in the PV Industry

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

SILICon IrrADIAnCe SenSor

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China

Advances in Silicon Technology Enables Replacement of Quartz-Based Oscillators

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

2520 Pulsed Laser Diode Test System

Evaluation of high power laser diodes for space applications: effects of the gaseous environment

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources

SolarWorld Africa (Pty) Ltd Davis & Shirtliff Kenya

Commercial Aviation Interconnects. & Value-Added Services CAB-6.18

Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

RFID Antenna Family. RFID antennas for fixed readers. Comprehensive RFID antenna portfolio for diverse application needs

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

APS M1P Single-phase Micro-inverter Installation and User Manual

THE DESERT KNOWLEDGE AUSTRALIA SOLAR CENTRE: HIGH VOLTAGE EFFECTS ON INVERTER PERFORMANCE.

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR

Customized Sensors. OEM Custom-designed Sensors...from the leader in the measurement of mechanical parameters

Performance Loss of PV systems. Giorgio Belluardo

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Proprietary Calibration Certificate

RFID Antenna Family. RFID antennas for fixed readers. Comprehensive RFID antenna portfolio for diverse application needs

Application Note: String sizing Conext CL Series

Real-time non-contact wet or dry thickness measurement of pressure sensitive, water based, hot melt, laminating and other adhesives

Potential Induced Degradation (PID) Study of. Fresh and Accelerated Stress Tested Photovoltaic Modules. Sandhya Goranti

Tested and ready to use Quality from a single-source

PID: an invisible danger for solar systems and how to prevent it

Company Introduction

1) Solar simulator with I-V measurement setup and software

ID SERIES OUTDOOR INDUSTRIAL DIPOLE ANTENNA

DC PV Arc fault detection Unit

Laboratory 2: PV Module Current-Voltage Measurements

Measurement of the thickness of thin foils and testing of the heat sealing of food and medicinal packaging

HARTING Coaxial and Metric Connectors

Sabritec Qualification Test Report Summary

Test Report. File No.: SHV01032/18-02 Test Report No.:

Oriel Sol3A Class AAA Solar Simulators

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

RD1000 Ground Probing Radar

1. Executive Summary. 2. Introduction. Selection of a DC Solar PV Arc Fault Detector

Sunny Smile with Hyundai

Turning the wheels of your success

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Wire management is key to productivity in wafer production

Hermetic Packaging Solutions using Borosilicate Glass Thin Films. Lithoglas Hermetic Packaging Solutions using Borosilicate Glass Thin Films

INDUSTREX (installed and tested prior to shipping) Windows 7 Ultimate 64 bit Filter

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

Pag 1 of 15. Eurotest Laboratori S.r.l. Via Marconi, Brugine (PD) Italy

Crystallize Your Visions in the Photovoltaic and Semiconductor World CCIC. Competence Center for Industrial Crystal Growing Systems

TRENDS IN MAGNET WIRE TERMINATION White Paper

SOLARONIX. Solixon A-1525-V

INTREPID Model 336 Digital Microwave Link

Flash Stamp Machine T1511M User Manual

Performance of SolarPod TM Crown Dr. Mouli Vaidyanathan, PhD PE, Eagan Minnesota 55123

Standby Power. Primer

Wisconsin Place Residential Chevy Chase, MD

MC2301. Features and Benefits. Promotional Highlights TUBE POWER AMPLIFIER MCINTOSH LABORATORY INC., 2 CHAMBERS STREET, BINGHAMTON, NEW YORK 13903

paint for coil coating

Military & Defense Interconnects. & Value-Added Services MDEFB-6.18

Understanding Infrared Camera Thermal Image Quality

FT702LT HEAVY DUTY WIND SPEED AND WIND DIRECTION IN ONE TOUGH PACKAGE FT702LT. series

TECHNICAL PRODUCT DATASHEET

Gap Analysis towards A Design Qualification Standard Development for Grid-Connected. Photovoltaic Inverters

High-Reliability and Environment Qualified Components

About Us. 65 Years in Business. Products in Service Worldwide. Fully Integrated Company. Design / R&D / Manufacturing / Testing / Support

APS M1P Single-phase Micro-inverter Installation and User Manual

Slim compact safety relay

Reference: Photovoltaic Systems, p

Transcription:

May 2010

The Nanosolar Utility Panel 1 Designed for Utility-Scale Performance The Nanosolar Utility Panel is specifically designed for utility-scale systems. Engineered to reduce totalsystem cost, the product is electrically and mechanically optimized for utility-scale solar power systems: Electrically capable of supporting more than 6 Amps (A) of current, the Nanosolar Utility Panel is one of the industry s highest-current thin-film panels. It is also the industry s first photovoltaic panel certified by TÜV for a system voltage of 1,500V. High current and system voltage enable longer panel arrays, resulting in a host of cost savings during installation. Mechanically, the dual-tempered glass/glass package used for the Nanosolar Utility Panel is stronger than conventional thin-film-on-glass panels, delivering almost twice the mounting span, and requiring less mounting hardware. The Nanosolar Utility Panel meets and exceeds all tests required by applicable IEC and UL standards, including separate certification of the Nanosolar Edge Connector. State-of-the-art robotic automation is used to assemble the Nanosolar Utility Panel in a factory near Berlin, Germany, delivering the highest degree of quality. 2 Product Features and Benefits Based on an industry proven glass/glass laminate package engineered for more than 25 years of reliability, the panel s unique features and benefits include the following: High-Power Panel for Faster Deployment At power ratings ranging from 160W to 220W, the Nanosolar Utility Panel has up to three times more power per panel than conventional thin-film panels. More power per panel simplifies industrial-scale deployment. Tests have shown a significant reduction in installation labor time relative to conventional thin panels (see Reduced BoS Cost: Mounting and Cabling Labor, page 4). Rugged, Hermetically Sealed Package for Maximum Reliability A rugged glass/glass package with encapsulation based on a hermetic edge seal is used to ensure maximum durability and to eliminate moisture ingress. Nanosolar encapsulant technology is engineered to exceed the sealing performance of conventional thinpanel products, providing an additional safety buffer for 25 year reliability. Mechanically Strong Package for Wide-Span Mounting Conventional thin-film-on-glass panel manufacturers deposit the solar-cell stack of thin films directly onto a glass pane, which also offers protection from the outside environment. Nanosolar produces individual foil cells, sorts them into electrically matched circuits, and assembles these circuits into a panel. By utilizing sorted-cell assembly, Nanosolar gains a panel assembly yield advantage and broad flexibility in terms of panel size, form factor and package style. The Nanosolar Utility Panel uses tempered glass on both the front and back of its glass/glass package. Note that the use of two tempered glass panes is not possible for producers of thin-film-on-glass panels, because high-temperature cell production process steps lead to de-tempering. The Nanosolar Utility Panel - May 2010 2

The use of dually tempered glass panes with foil cells in between creates a package of significant mechanical strength. Tempered glass has a strength of 120MPa, three times stronger than regular glass. The resulting system benefit is that it enables wide-span mounting, which reduces the cost of mounting materials and labor. High-Current, High-System-Voltage Design for Utility-Scale Panel Arrays With capacity to generate currents of 6-7 Amps, the Nanosolar Utility Panel is one of the highest-current thin-film panels in the industry, and the first photovoltaic panel certified by TÜV for a system voltage of 1500V. Once a string of panels reaches the system voltage, a DC cable home run is required to carry the power to an inverter. If the panel s current is low, as is the case with many thin-film-on-glass products, the system voltage is reached with fewer panels, requiring more DC cabling home runs for the same amount of installed power. The electrical characteristics of a panel combined with its physical length determine the panel string length, the maximum length per row of panels that can be wired in series before a home run is required. Panel string length = System voltage Open-circuit voltage* x Panel length** *Open-circuit voltage at low temperature. **Panel length in mounting orientation. The Nanosolar Utility Panel supports a panel string length of 64m, several times longer than leading thinfilm panels currently in use for large-scale ground installations. In utility-scale systems, where distances are vast, a longer panel string substantially reduces cabling requirements. (see Reduced BoS Cost: Cabling Length and Labor for further detail) Nanosolar Edge Connector for Fast, Minimal-Resistive-Loss Interconnection Nanosolar has developed a new form of cabling connection for the Nanosolar Utility Panel. A component separately tested and certified by TÜV according to the applicable connector standards, the Nanosolar Edge Connector is designed to reduce cabling labor, save material cost, and minimize resistive losses for utility-scale system deployments. Figure 1: The Nanosolar Utility Panel mounted in landscape mode. There are two Nanosolar edge connectors per panel. A short cable connects each panel from left to right. The Nanosolar Edge Connector is designed to enable high system voltage and to simplify electrical connection. Field tests performed by an independent third party have shown a reduction in labor time for panel interconnection relative to conventional thin film panels. The Nanosolar Utility Panel - May 2010 3

3 Reducing Balance-of-System Cost Compared to conventional thin-film panels, these Nanosolar Utility Panel features and benefits have the following cost advantages: Nanosolar Conventional Thin Film Nanosolar Advantage Power (W) 160-220 70-80 3x More Power per Layup Step Current (A) 6 1 Longer Panel String System Voltage (V) 1500 1000 Longer Panel String Panel Size (m 2 ) 2.0 0.72 Less Mounting Time Panel String Length (m) 64 12 Fewer Inverter Home Runs Mounting Span (m) 1 0.6 Less Mounting Material Connectors Edge Standard Significant Savings in Cabling Material Table 1: The Nanosolar Utility Panel stretches performance characteristics along several key dimensions relative to conventional thin panels. These technology attributes drive BoS and deployment cost efficiency in several key ways. The design of the Nanosolar Utility Panel enables BoS cost savings on mounting labor, cabling labor, mounting materials, and cabling materials, as further described below. Reduced BoS Cost: Mounting and Cabling Labor Solar panel installations require two types of cabling: Series interconnection of panel strings DC cable home runs to the inverter The high current, high system voltage design of the Nanosolar Utility Panel simplifies both types of cabling. Simplified cable harnesses can be utilized which reduce the number of series interconnections. In addition, fewer DC cable home runs are required, resulting in a significant savings in labor time. DC cables are typically placed in trenches, which must be dug and covered. In addition, each cable requires connections to both the panel string and the inverter. A third party performed time-clocked tests in a field in Germany, where trained teams of installers mounted 18 square meters (1800W) each of conventional thin film panels and Nanosolar panels. The Nanosolar Utility Panel required 30% less mounting time and 85% less cabling time. The Nanosolar Utility Panel - May 2010 4

Nanosolar panels Conventional thin-film panels Figure 3: Panel size drives balance-of-system cost savings on mounting labor and panel-to-panel cabling. Balance of System Cost: DC Cabling Nanosolar First Conventional Solar Thin Film 138*96 = 13,248 panels 230*160 = 36,800 panels = 4*12 panels = 10*10 panels 8*12 = 96 panels 16*10 = 160 panels 23*4 = 138 rows 23*10 = 230 rows Figure 4: Two example 2.66MW systems, one designed with the Nanosolar Utility Panel, and one employing a conventional thin film panel. Field dimensions are 300m x 230m. DC Cabling is represented by orange lines. Panel string length is 64m for Nanosolar and 12m for conventional thin film. The system designed with conventional thin film panels requires 17 home runs while the Nanosolar Utility Panel system design requires only 4 home runs. The Nanosolar Utility Panel installation utilizes 73% less DC cabling than the conventional thin film installation. The Nanosolar Utility Panel - May 2010 5

Reduced BoS Cost: Mounting and Cabling Materials The wide-span mounting capability of the Nanosolar Utility Panel reduces BoS cost on mounting materials as illustrated in the following figure. By virtue of having a larger spanning distance than conventional thin film panels, 40% fewer Aluminum or steel rails are needed for mounting, reducing a substantial fraction of materials cost. Figure 2: Wide-span mounting drives BoS cost savings on mounting materials. The arrow above indicates the freespan distance that a panel must sustain mechanically (with snow loads up to 5400Pa) when installed in a typical railmount configuration. The larger the mounting span, the fewer rails are necessary. The Nanosolar Utility Panel supports a higher current (6A) and a higher system voltage (1500V) than industry-leading thin film panels, enabling a longer panel string length and reducing the cost of cabling materials. Fewer cable harnesses, string combiner boxes, and fuses are needed; in addition to the total length of cabling required for the installation. The length of DC cabling, in particular, is significantly reduced as fewer home runs are required to the inverter. 4 Performance A solar panel s nominal power rating is measured under laboratory conditions, normally Standard Test Condition (STC) with an artificial light source referred to as a flasher. Actual operating conditions differ from STC. Consequently, this laboratory-based approach requires a host of correction calculations to be applied on the raw measurement data, adjusting for spectral effects, temperature differences, temporal length of the flashed light pulse, and other factors. Nanosolar collaborates with leading third parties to continuously verify its flasher setup, calibration and methodology. The Fraunhofer Institut für Solare Energiesysteme successfully validated Nanosolar s factory flasher ratings through a series of flash tests on the Nanosolar Utility Panel at Fraunhofer s Freiburg-based facility; the separate flash measurements were within a ±1.5% deviation of Nanosolar s flash results. While flasher ratings depict the capacity of a panel to produce electricity, most meaningful panel performance data is collected through outdoor measurements of actual pre-inverter (DC) and postinverter (AC) electricity generated by installations of panels. The Nanosolar Utility Panel - May 2010 6

Outdoor test installations with the Nanosolar Utility Panel have been maintained since 2009 in a variety of geographic and climatic locations, including Nanosolar-operated and customer-operated installations in France, Germany, California, and Arizona. Figure 5: Nanosolar maintains a series of outdoor test installations in a geographically diverse range of locations and climates, including France, Germany, California, and Arizona. kwh energy delivery performance and normalized kwh/wp energy harvests have been tracked on an ongoing basis under identical conditions for crystalline silicon panels, conventional thin film panels, and Nanosolar Utility Panels. The gathered data shows that the performance of the Nanosolar Utility Panel is competitive with both. Based on flash test results and outdoor field performance measurements, Nanosolar Technical Notes on Performance Estimating are available to Nanosolar customers and summarize necessary input parameters for solar energy simulation programs such as PVSYST and PV*SOL. 5 Reliability The Nanosolar Utility Panel architecture safeguards the embedded solar cells from environmental impact. Extensive internal and third-party reliability testing has shown the Nanosolar Utility Panel to be highly reliable and extremely robust. The Nanosolar Utility Panel received successful certification upon its first submission to TÜV. Nanosolar Utility Panel Meets All Requirements According to IEC The Nanosolar Utility Panel is certified by TÜV Rheinland PTL, LLC Photovoltaic Testing Services according to IEC 61646 Thin-film terrestrial photovoltaic (PV) module design qualification and type approval; IEC 61730 Photovoltaic (PV) module safety qualification; and UL 1703 Electrical Safety and Class A Fire Resistance. The Nanosolar Edge Connector also received a separate TÜV certification. Nanosolar Utility Panel Engineered to Meet Testing In Excess of IEC As of the spring of 2010, the Nanosolar Utility Panel safely exceeds the IEC time and cycle testing limits. Extending the scope and intensity of gold plate TÜV reliability testing to gain even more confidence in >25-year panel durability, Nanosolar continuously performs internal panel and component stress tests in excess of the IEC 61646 standard. Internal reliability testing emphasizes test-to-fail methodology, as this provides a quantitative characterization of the panel s safety margins under extreme conditions. The Nanosolar Utility Panel - May 2010 7

Rigorous Internal Testing Nanosolar continually performs a series of reliability tests, with a focus on component and material endurance, including: Temperature cycle testing Edge-box safety testing: damp heat, humidity freeze, and temperature cycling. Exposure of the Nanosolar Utility Panel to intense amounts of salt fog; Accelerated exposure of the panel edge seal, encapsulant, edge box and ribbon connectors to UV light (UV-A and UV-B) in an amount equivalent to 25 years; Accelerated testing of edge seal performance equivalent to 25 years of moisture and thermal cycling; Vibrational fatigue, bullet and sheer-force tests; Thermal freeze stress test. 6 Quality The Nanosolar quality system controls the entire production process from supplied raw materials to customer service and support. The manufacturing of the Nanosolar Utility Panel is based on fullyautomated assembly in a robotic factory with state-of-the-art in-line quality measurement controls. Incoming materials are qualified through extensive testing for performance and reliability before being released into production. All critical component and material attributes are clearly defined and regularly tested by Nanosolar suppliers. The results are confirmed in Nanosolar labs or independent labs. Process parameters on Nanosolar manufacturing equipment are the result of numerous tests, and are controlled with hundreds of sensors and lines of data, with the most critical aspects under statistical process control. Regular sampling and lab testing ensure that processes remain in tight control, and form the basis for continual improvements. Final flash testing of Nanosolar cells and panels confirm that the panels meet performance specifications, and also feeds data back to the processes where it is analyzed for potential process improvements. First In, First Out (FIFO) is built into the production system. Nanosolar data systems can track a panel and its components all the way back to a cell s raw materials and processing parameters. Tied together with regularly scheduled reliability testing, this enables Nanosolar to identify potential product issues well before a customer experiences them in a field installation. Cross functional teams solve manufacturing and quality issues using Toyota s 6 step problem solving methodology, entering them into a quality management system that provides a library of solutions and countermeasures for quick problem resolution. The Nanosolar quality system helps manage daily development and production, and also builds a vast library of data, tools and best practices for continuous improvements in the future. The Nanosolar Utility Panel - May 2010 8

Figure 11: The assembly of the Nanosolar Utility Panel is completely automated in order to meet the highest quality standards. 7 Summary The Nanosolar Utility Panel is designed and developed specifically for utility-scale performance. By introducing a series of improvements to an industry-proven package with established reliability performance, the panel allows system integrators to significantly reduce BoS cost, and to achieve a gridparity levelized cost of energy in many utility-scale applications. The Nanosolar Utility Panel - May 2010 9