SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

Similar documents
SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Adjustable Countertop Installation

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION PRE-MANUFACTURED CABINETS

WIRE SHELVING. Joiner Plate -6667, 6687, Item Description " Shelf & Rod " Shelf & Rod

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

Thanks for shopping with Improvements! Deluxe 10 Closet Organizer (12 deep) Item #461609

1.1 RELATED DOCUMENTS

Design and Construction Standards SECTION ATHLETIC LOCKERS

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

PRODUCT INFORMATION Penco Wide-Span Shelving

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

Product Guide Specification

SECTION HOLLOW METAL DOORS AND FRAMES

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

SECTION CARPENTRY

MONKEY BARS OVERHEAD RACK INSTALLATION

Assembly and Installation Guide

Walk-in Configurations

AUXILIARY FRAMING AND ACCESSORIES

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

MANUFACTURING INC. Specifications

Installation Instructions

SECTION ARCHITECTURAL WOODWORK

SECTION BULLET- RESISTANT DOORS

SECTION 19: Endwood Fusion Welded Gate Installation Guide

TIP FOR GETTING STARTED

Mounting Brackets for 8450 Drawer Slides KV Front Bracket 20 $1.30 KV P Rear Bracket 20 $5.20

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

SECTION MANUFACTURED CASEWORK

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

Installation Instructions

St. Monica Food Pantry

4. Metal roof jacks at penetrations and attachments

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

ULT R A S PACE SAV E R SQ UA R E D

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

Tufftec Lockers Specifications & Drawings SPECIFICATIONS & DRAWINGS

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

CSI Section DMI Light Gage Structural Steel Framing Systems. Blocking Fire Rated Pre-cut (Proprietary) Furring Wall Preservative Treated

LPR System Installation instructions

1. Layout. Step 1. Step 2. Step 3. Fig. 1

SLATTEX (Textured Slatwall) INSTALLATION GUIDE

Project: # Solano Community College District

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

B. Related Sections include the following: 1. Division 16 Sections for basic electrical and telecom design requirements

ULT R A SPAC E SAV E R

SECTION METAL FABRICATIONS

FLUOROPOLYMER COATED DUCT FOR CAUSTIC ENVIRONMENTS

INSTALLATION INSTRUCTIONS

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

INSTALLATION INSTRUCTIONS

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

SECTION FOLDING GLASS PANEL PARTITIONS

ENDUREED VIVA SERIES Specifications

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

Leveling System Solutions

Coordinate installation of rough carpentry members specified in other sections.

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM CASEWORK

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Parveneer Positive Pressure Fire Rated Frames Double rabbet with T stop for 20 minutes

AIA Specification. Section Slate Shingles PART 1 GENERAL

Training Manual. SCHULTE freedomrail Training Manual Page 1

INSTALLATION INSTRUCTIONS

Installation Instructions for. Handrail Component System

Product Guide Specification

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Extra Wide Designer Lockers Series Installation Instructions

K.D. LOCKER ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Box Edge Plus Steel Shelving Installation Instructions

Log Siding J Block. Outlet J Block 4 3/4 x 7. Fixture J Block 7 x 7

LA-1010 User s Manual 3 in 1 Stud/Metal/AC Voltage Finder With Laser Line Level.

SECTION THERAPEUTIC POOL ACCESSORIES

Worktop INDEX eight Capacity Unpacking

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

JURALCO ALUSTORE MODULAR STORAGE SYSTEM. Modular Storage System. Issue 1/16 ISSUE 1/16. ph (09)

Tuxedo Console Table INSTALLATION INSTRUCTIONS P73037, P73038, P _2_B Page 1 of 5

9 X 12 FIXED TYPE ALUMINUM WINDOW BARS INSTALLATION INSTRUCTIONS Import Note : 9 X 12 Spacing Fixed Type Installation is covered in this Instruction.

PLM CABINET AND MTL LIGHT INSTRUCTIONS

BUILDING PLANS. BUILDING DEPARTMENT

SECTION COUNTERTOPS ecox PART 1 GENERAL

LOCKER SPECIFIERS GUIDE. The standard of excellence for business, industry and institutions. Lockers Cabinets Shelving

Alexandra Secondary College Refurbishment Project No: 1507 SECTION MANUFACTURED CASEWORK - SHOP BUILT 12300/1

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Transcription:

SECTION 10 57 23.13 (10670) - WIRE CLOSET AND UTILITY SHELVING PART 1 GENERAL 1.01 SUMMARY 1. Wire Closet Shelves B. Related Sections: 1.02 SUBMITTALS 1. Section 06 10 00 (06100) - Rough Carpentry A. Submit "Letter of Conformance" in accordance with Section 01 33 00 (01330) with the following supporting data: 1. Mark each copy to identify applicable products, characteristics, models, options and other supplemental data to clearly communicate information specific to this Project. 2. Color Chart: Each product specified. 1.03 QUALITY ASSURANCE A. Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation of units required for this Project. B. Source Limitations: Obtain metal storage shelving through one source from a single manufacturer. 1.04 DELIVERY, STORAGE, AND HANDLING A. Deliver storage shelving palleted, wrapped, or crated to provide protection during transit and Project-site storage. 1.05 PROJECT CONDITIONS A. Environmental Limitations: Do not deliver or install metal storage shelving until spaces are enclosed and weatherproof, wet work in spaces is completed and dry, and ambient temperature is being maintained at the levels indicated for Project when occupied for its intended use. PART 2 PRODUCTS 2.01 WIRE CLOSET SHELVES A. Avendra, LLC Preferred Manufacturers: 1. None B. Approved Manufacturers: 1. Lifetime Ventilated Series Shelf with Hanging Rod ; Organized Living (888-674-5484) C. Components: 1. Structural Performance: a. Structural Performance: Back clips spaced 11 inches with support braces at 3 feet 6 inches. b. Static Load: 75 lb/ft of shelf minimum. c. For heavy duty applications in pantry and garage applications space support brace on 2 feet. PAGE 1

d. Back Clips and Down Back Clips shall be Tri-Loc II Patented hollow wall anchoring system. 2. Material: Minimum requirements. a. Steel Rod: Grade C 1008 cold drawn steel rod. Tensile strength of 100 ksi. b. Front Rods and Studs: 0.306 inch diameter. c. Back Rods: 0.243 inch diameter. d. Cross Wire Spacing: 1 inch spacing. 0.120 inch diameter for one inch spaced standard 20 inches shelf. 0.105 inch diameter for one inch spaced standard mesh shelf. e. Cross Wire Spacing: 1/2 inch spacing. 0.0915 inch diameter for one-half inch spaced tight mesh shelf. 3. Shelving: a. Hanging Shelf with Open Slide: 12 inches deep by length as shown on Drawings. b. Storage Shelf: 12 inches deep by length as shown on Drawings. 4. Mounting Hardware: Manufacturer's standard components including anchor clips, end brackets, angled support braces and end caps, including the following: D. Finish: a. Side Wall Bracket: As required. Shelf side wall interface. b. Support Brace: Maximum 42 inches and every open end Anchor Back Clips. c. Fasteners, clips, caps and touch-up all as required. d. Down Back Clips. 1. Electrostatic applied oven cured epoxy at all surfaces to 3 to 5 mil thickness. a. Color: Pure White E. Configurations: Note: Descriptions below are based on the Closet configurations shown on the Drawings. Verify configurations and parts list below with actual Project room sizes and configurations. Contact the Organized Living company for any modifications required. 1. Standard King Guestroom Wire Shelves: (Drawing 420) PAGE 2 REVISED: 06/08/15 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2015, Marriott International, Inc.

2. Accessible King Guestroom Wire Shelves: (Drawing 421) above finished floor. Hanging rod to be located under open section of Closet 1 (Up to 30 Wide) 3. Extended King Guestroom Wire Shelves: (Drawing 422) 4. King Suite A Guestroom Wire Shelves: (Drawing 426) PAGE 3

5. King Suite B Guestroom Wire Shelves: (Drawing 427) 6. Accessible King Suite B Guestroom Wire Shelves: (Drawing 428) above finished floor. Hanging rod to be located under open section of PAGE 4 REVISED: 06/08/15 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2015, Marriott International, Inc.

7. King Inline Suite Guestroom Wire Shelves: (Drawing 429) 8. Accessible King Inline Suite Guestroom Wire Shelves: (Drawing 430) above finished floor. Hanging rod to be located under open section of PAGE 5

Closet 1 (Up to 30 Wide) 9. Standard Queen/Queen Guestroom Wire Shelves: (Drawing 431) 4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 10. Accessible Queen/Queen Guestroom Wire Shelves: (Drawing 432) above finished floor. Hanging rod to be located under open section of Closet 1 (Up to 30 Wide) PAGE 6 REVISED: 06/08/15 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2015, Marriott International, Inc.

11. Extended Queen/Queen Guestroom Wire Shelves: (Drawing 433) 4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 12. Queen/Queen Suite B Guestroom Wire Shelves: (Drawing 434) 4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 13. Accessible Queen/Queen Suite B Guestroom Wire Shelves: (Drawing 435) above finished floor. Hanging rod to be located under open section of PAGE 7

14. Queen/Queen Inline Suite Guestroom Wire Shelves: (Drawing 436) 15. Accessible Queen/Queen Inline Suite Guestroom Wire Shelves: (Drawing 437) above finished floor. Hanging rod to be located under open section of PAGE 8 REVISED: 06/08/15 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2015, Marriott International, Inc.

PART 3 EXECUTION 3.01 INSTALLATION Closet 1 (Up to 30 Wide) A. Install in accordance with manufacturer's published instructions, square and plumb, secured rigidly in position. 1. Layout scheduled components prior to installation to verify wall to wall and floor to ceiling heights, widths, plumb and flatness of surfaces. 2. Prepare anchor locations and select anchor types using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. END OF SECTION PAGE 9