MCR-304. Installation Instructions. Wireless Interface for Hard-Wire Control Panels 1. INTRODUCTION 2. SPECIFICATIONS. 1.

Similar documents
FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

INSTALLATION INSTRUCTIONS

RFTX-1 Installation Manual

INSTALLATION INSTRUCTIONS

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

User Manual. ProRF Encoder Transmitter & Receiver

INSTALLATION AND SETUP GUIDE

User s Guide FM Transmitter

Transmitter. User Manual. Firmware version 1.0 and greater

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

T-L 810-T TRANSMITTER GUIDE

STI REPEATER HOW THE PRODUCT WORKS BEFORE YOU START. Installation and Operation Manual. Model: STI-34109

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

User Manual Digital Wireless Rain Gauge

WS-9006U Wireless Temperature Station

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

PTT- Z or PTT-U PUSH-TO-TALK Specification

IRRIGATION 810-T TRANSMITTER GUIDE

Pocket Weatheradio with Tone and Vibrating Alert

Keychain Radio Remote Control System

HORNET Remote Control Systems

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

ACT-IR220Li/220LN IrDA Serial Port Adapter

STI REPEATER. BEFORE YOU START Refer to this drawing to become familiar with all the parts. Installation and Operation Manual.

Uplink 5500EZ. Installation and User Guide. S e pte m be r 1 2,

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

AM/FM Stereo Headset Radio

AIS 300 Installation Instructions

NEO CAR AUDIO. Neo AUXiN AUX INPUT INTERFACE. Instruction Manual

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

How to install your ecobee Switch+

SSR VL-12P-xC-NCS

User s Guide Instructions for Installation and Operation

ACT-IR220L/LE IrDA Serial Port Adapter

SSR-150xxx-40VL-12P-xC-xxxCS

Technical Support, End User License & Warranty Information

MPRF01 Wireless 5uA Inductive Proximity Sensor RF System

IRRIGATION 810-3R RECEIVER GUIDE

WIRELESS BLUETOOTH AUDIO TO ANY CAR RADIO MAKE THE CONNECTION

Wireless Expansion Module V1.0 Reference & Installation Manual

Remote Control Outlets Operating Instructions

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Using the USB Output Port to Charge a Device

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

C-Bus 8 Channel Low Voltage Relay

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

Radio Controlled timekeeping. Receives 60KHz WWVB signal transmitted by NIST in Fort Collins, Colorado

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

CarConnect Bluetooth Interface General Motors Owner s Manual

IRRIGATION 810-R RECEIVER GUIDE

Radio Remote Controls Manual K Series

Ambient Weather F007PF 8-Channel Wireless Water Thermometer User Manual

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

COMMERCIAL TRANSMITTER INSTRUCTIONS

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

IS76 Beacon with Ferrite Antenna Installation Manual

f i r e - p a r t s. c o m

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

900MHz Digital Hybrid Wireless Outdoor Speakers

TARGETuner Antenna Management System for Screwdriver Antennas

Owner s. Manual. Expand Your Factory Radio. Honda/Acura. Media GateWay PXAMG. HD Radio Operation. isimple Connect

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

Ambient Weather F007TH Wireless Thermo-Hygrometer User Manual

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

TR1000 IRRIGATION MANUAL

Comfort 10S Wall Hardwire Installation and Operations Manual

OWNER S MANUAL DANGER

Owner s Manual MRX-10 Advanced Network System Controller

Table of Contents. Mounting Diagram.. Wiring Information.. Setting the STR 1000 as a Repeater or a Transmitter. STR 1000 Frequently Asked Questions..

Radio Remote Controls Manual K Series

Owner s Manual. MRX-2 Network Base Station

Ambient Weather F007TP 8-Channel Wireless Probe Thermometer User Manual

Ambient Weather WS-40 Wireless Indoor / Outdoor Thermometer

MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller

User s Guide Instructions for Installation and Operation

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

LEDs: green = on amber = off blue = pairing red = replace battery. Press the power button to turn on / off.

Thermometer model 02059

User s Guide ASSISTIVE LISTENING SYSTEMS

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

IS76 Beacon with Ferrite Antenna Installation Manual

Quik Bridge Loop Receiver Installation Instructions

Super Switch Indoor Wireless Remote Control Wall Outlets

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

14 CHANNEL FAMILY RADIO SYSTEM MODEL # FR142

X80 Activator. User's Manual. Version 1.1.

TriggerLinc. INSTEON Wireless Door Window Sensor (Open/Close) Model : 2421

Gypsy Statement of Limited Warranty. Part 1 General Terms

Preliminary Data Sheet!

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Transcription:

Wireless Interface for Hard-Wire Control Panels Installation Instructions 1. INTRODUCTION 1.1 Purpose and Use The is a single output wireless PowerCode / CodeSecure receiver designed to add fully supervised wireless capabilities to hard-wired control panels, as demonstrated in Figure 1. The can be connected to various control panels for remote control purposes and can use up to 10 Powercode / CodeSecure wireless devices for remote control. The will recognize only those devices with IDs that have been taught into its non-volatile memory. Other devices will be ignored. Detailed teaching/learning procedures are provided in Paragraphs 3.4 and 3.5. The provides trouble, low battery and tamper outputs which are common to all 10 wireless devices. 1.2 Control Output The features a single FORM-1C relay output that reacts to control signals received from up to 10 wireless detectors or hand-held transmitters. The relay can be programmed to operate in the Pulse or Toggle modes (see Para. 4.4 for full details). Replacing the battery in the transmitter that sent the low-battery message and transmitting once again resets the output. Trouble: This output is activated if a supervised transmitter fails to send its attendance message within a 4-8 hours time frame. 1.4 Construction Details For construction details, refer to Figure 2. WIRELESS POWERCODE OR CODE-SECURE TRANSMITTERS AND DETECTORS (UP TO 10 UNITS) RECEIVER PUT TROUBLE LOW BATTERY TAMPER + - Figure 1. Typical Application of the HARD-WIRED 24 HR TROUBLE ZONE 24 HR BATERY SUPERVISION ZONE 24 HR TAMPER ZONE S 1.3 Status Outputs In addition to the single relay output, the provides 3 opencollector status outputs that function as follows: Tamper: This output is activated once a TAMPER state is detected in a transmitter or in the receiver itself. Low Battery: This output is activated whenever a low battery message is received from one of the detectors/transmitters. Figure 2. with Cover Removed 1.5 Receiver Operating Modes Two operating modes are available: OPERATE - normal position (receiver stands by for signals) LEARN - enrollment of transmitter IDs in the memory. 1.6 LED Functions during Operation SINAL indicator (red - visible through a hole in the cover): This LED illuminates when the output relay is energized and continues to light for as long as the relay remains energized. The LED extinguishes when the relay drops out. Note: The red LED has a different function during the learning session (see Paragraphs 3.4 and 3.5). Memory Location indicator (yellow - visible only when the cover is removed): This LED is extinguished in normal operation, but has a special function during the learning session. 2. SPECIFICATIONS RF SECTION Front-End Module: Super-regenerative UHF receiver. Operating Frequency: Per local requirements in country of use. DATA PROCESSIN SECTION ID codes: Over 16,000,000 possible 24-bit combinations. Total Message Length: 36 bits (66 bits for code secure devices) ID Learning Capacity: Up to 10 different ID codes ELECTRICAL DATA Relay Outputs: Form 1C (N.C. and N.O.) Relay Contact Ratings: 1A resistive, 30 VDC or AC. Status Outputs: 3, up to 100 ma each, open-collector type Relay Output Modes: Pulsed (3 s) or toggle, jumper selected. Tamper Switch Ratings: 0.1 A / 30 VDC. Input Voltage Range: 10.5-16 VDC () or 24 VAC/DC (U) Current Drain (@ ): 7 ma (standby), 32 ma (relay energized). Compliance with Standards: FCC Part 15, CE (ETS 300220, ETS 300683). PHYSICAL Operating Temperatures: 0 C to 49 C (32 F to 120 F). Dimensions (H x W x D): 110 x 63 x 25 mm (4-5/16 x 2-1/2 x 1"). Weight: 76 g (2.7 oz). DE3174 1

3. PRORAMMIN 3.1 Helpful Hints A learning session is required to let the learn the ID codes of individual wireless transmitters, which will all affect its single relay output. The quickest way to conduct a learning session is on the work bench, with every transmitter you need within reach, and where you may observe the receiver s indicator LEDs. 3.2 Initial Steps A. Remove the screw that secures the cover to the base and remove the cover as shown in Figure 3. B. Round up all transmitters to be used in the system and mark each one according to Figure 3. Cover Removal the desired deployment plan. It is advisable to use the transmitter deployment table at the end of this document. C. Temporarily power up the by connecting a 12 V battery or a power supply across its 12 V input terminals (24 Volts AC or DC in case of U). Observe polarity! 3.3 Selecting Memory Locations The transmitter ID memory is divided into 10 locations, one per each transmitter ID. Memory locations may be selected in ascending order from 1 to 10, by clicking the tamper switch. The yellow LED indicates which memory location is selected. The information is conveyed by flashing sequences as demonstrated in the following chart: No. of Clicks Mem. Loc. Flashing Sequence of the Yellow LED One 1 st... Two 2 nd... Three 3 rd... Four 4 th... Five 5 th... and so on, until the tenth click = Flash; = Pause 3.4 Learning Transmitter IDs A single transmission (control signal, Tamper or Restore) is required to enroll a transmitter s ID in the memory. A specific transmitter s ID may be enrolled in as many locations as desired. Note: In case of PIR detectors, in which batteries are already installed, cover the detector s lens to prevent accidental transmission during the learning session. For teaching transmitter IDs, proceed as follows: A. Remove the cover. B. Set the OPERATE / LEARN jumper to LEARN as shown at the right. The yellow LED will start flashing at a constant rate. C. Click the tamper switch the correct number of times to select the desired memory location (see Para. 3.3.). Each click advances to the next memory location. The red LED will show the status of the selected location as follows: Status Location is free LED Flashes Location already contains an ID LED Lights steadily To clear a busy location, refer to Para. 3.5. D. If the memory location is free, initiate a transmission from the transmitter you wish to enroll in the selected location. Two kinds of response may be expected: Lights steadily Continues to flash Significance Transmitter ID enrolled Transmitter ID not enrolled Note: You can not enroll a transmitter in a busy location. E. Repeat Steps B through D for all of the remaining transmitters.. When done, quit the LEARN mode by setting the OPERATE / LEARN jumper back to OPERATE, as shown at the right. CAUTION! While handling the jumper, take care not to touch the delete button located close to the jumper. Notes: (1) If the transmitter used is a wireless detector, remove its battery to prevent accidental transmissions at a later stage of the learning session. (2) If you leave the jumper in the LEARN position and no further learning activity takes place for 5 minutes, the LEARN mode will be automatically abandoned. 3.5 Clearing Transmitter IDs A. Set the OPERATE/LEARN jumper to LEARN. The yellow LED will start flashing at a constant rate. B. Click the tamper switch the correct number of times (up to 10) to select the desired memory location (see Para. 3.3). The red LED will show the status of the selected location as follows: Status Memory location is free LED Flashes Memory location already contains an ID LED lights steadily C. Click the DELETE pushbutton on the circuit board once. The red LED will respond as follows: Flashes at a constant rate Continues to light steadily Significance Success (ID deleted) Failure D. When done, quit the LEARN mode by setting the OPERATE/ LEARN jumper back to OPERATE. 3.6 What if the ID is Not Enrolled? If the transmitted ID has not been accepted although the memory location is free (the red LED continues to flash), try transmitting again. If the second attempt is unsuccessful, the transmitter in question may be faulty. Try enrolling another transmitter. 4. INSTALLATION 4.1 Selecting the Mounting Location A. The location selected for the must constitute a compromise between maximum reception ability and minimum distance from the control panel. B. Maintain the antenna vertical - tape it to the wall if required. C. Avoid installing the on or near large metallic objects such as closets, circuit breaker cabinets, air conditioner ducts and fine-mesh window screens. D. Do not locate the unit near dense electrical wiring. 2 DE3174

4.2 Mounting the Base in Place To install the cabinet, proceed as follows: A. Hold the base against the mounting surface and mark the points for drilling (see mounting holes in Figure 2). B. Drill the mounting holes and insert wall anchors if necessary. Enter the wires into the base through the wiring knockouts. Attach the base to the mounting surface with two long screws. C. Complete the wiring as described in Para. 4.3. 4.3 Wiring (Figures 4 through 7) A. Connect the relay N.C. (or N.O.) and C terminals of the MCR- 304 to the selected zone input of the control panel in use. Note: If the control panel remote control zone input is defined as E.O.L., use appropriate E.O.L. resistors (see Figure 4). TROUBLE Z2 E.O.L. Figure 6. Wiring All 3 Status Outputs to a Single E.O.L. Zone TROUBLE Z2 N.C. C Figure 4. Using E.O.L. Resistors in the Relay Output Circuit B. If you wish to separate between status alerts, connect each status outputs of the (TAMP, LBT and TRB) to a separate zone input of the control panel, as shown in Figure 5. NOTE: THESE CONNECTIONS ARE CORRECT IF S ARE DEFINED AS NORMALLY OPEN NOTE: ALL THREE STATUS PUTS ARE NORMALLY OPEN. THEY PULL TO ROUND UPON OCCURRENCE OF LOW BATTERY, TAMPER AND TROUBLE EVENTS, RESPECTIVELY. +Vcc +Vcc +Vcc Figure 5. eneral Wiring Diagram C. If you prefer to use only one zone input for status alerts, connect all 3 status outputs of the to a single zone input of the control panel, as shown in Figures 6 (E.O.L. option) and 7 (relay option). COIL Figure 7. Wiring All 3 Status Outputs to a Single N.C. Zone 4.4 Customizing Your Receiver After wiring, you must set the relay output operating mode in accordance with the requirements of your specific application. Note: The relay output of the may be used for remote control tasks such as opening / closing a garage door. The PULSE / TOLE jumper determines the operating mode of the output relay (Pulse or Toggle): PULSE MODE Upon reception of a valid transmission, the output relay pulls in for as long as the transmission is received, plus 3 seconds. The relay will drop out when the pulse timer completes its countdown. Note: If another valid transmission is received during countdown, the pulse timer will be automatically reset and a new countdown will begin. TOLE MODE The output relay changes state each time it receives a valid transmission. Upon entering a new state, the toggle circuit is inhibited for 3 seconds, to impose a 3-second interval between states. Note: If another valid transmission is received during the 3- second inhibit period, the inhibit timer will be automatically reset and a new 3-second period will begin. 5. MISCELLANEOUS COMMENTS Supervised transmitters transmit an attendance message at 5.1 The Effect of Transmitter Type on regular intervals. If such a transmitter fails to send this message Output Relay Function in the PULSE on time, the will activate its TRB (trouble) output. Mode On the other hand, failure to receive an attendance message from a transmitter identified as a non-supervised device will be Upon receiving a signal from one or several restoral- reporting ignored by the. transmitters, the will energize its output relay and will keep it this way until all transmitters signals restore. 5.3 Product Limitations Visonic Ltd. wireless systems are very reliable and are tested to Note: If the system includes restoral reporting transmitters, it is high standards. However, due to their low transmitting power and not recommended to set the to the toggle mode. limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: 5.2 The Effect of Transmitter Type on A. Receivers may be blocked by radio signals occurring on or the TRB (Trouble) Output near their operating frequencies. The makes a distinction between supervised and nonsupervised transmitters. C. Wireless equipment should be tested regularly to determine B. A receiver can only receive one transmitted signal at a time. whether there are sources of interference and to protect against faults. DE3174 3

The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user's FCC authority to operate the equipment. This device complies with the European Council Directive EMC 89/336/EEC & 92/31/EEC and bears the CE mark and certification. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: Re-orient or re-locate the receiving antenna. Increase the distance between the device and the receiver. Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. Consult the dealer or an experienced radio/tv technician. Transmitter Deployment Table Memory Location Type of Transmitting Device Location / Task / Name of Holder 1 2 3 4 5 6 7 8 9 10 WARRANTY Visonic Limited (the Manufacturer") warrants this product only (the "Product") to the original purchaser only (the Purchaser ) against defective workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer. This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other reason, according to the Manufacturers discretion, such as improper installation, failure to follow recommended installation and operational instructions, neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not covered by this Warranty. The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the Product will prevent any death and/or personal injury and/or damage to property resulting from fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product, properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur. THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIATIONS OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDIN ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID. THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAES OR FOR LOSS, DAMAE, OR EXPENSE, INCLUDIN LOSS OF USE, PROFITS, REVENUE, OR OODWILL, DIRECTLY OR INDIRECTLY ARISIN FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAE. THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY INJURY AND/OR DAMAE TO PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION. However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply under certain circumstances. The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any telecommunication or electronic equipment or any programs. The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the Manufacturer s discretion any Product or part thereof that may prove defective. Any repair and/or replacement shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products. This Warranty is exclusive to the original Purchaser and is not assignable. This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply. Warning: The user must follow the Manufacturer s installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his/her safety and the protection of his/her property. 1/08 W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment. VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 VISONIC LTD. (UK): 7 COPPERHOUSE COURT, CALDECOTTE, MILTON KEYNES. MK7 8NL. PHONE: (0870) 7300800 FAX: (0870) 7300801 PRODUCT SUPPORT ( 0870) 7300830 INTERNET: www.visonic.com VISONIC LTD 2009 DE3174- (Rev. 3. 1/09) 4 DE3174