RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Similar documents
RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RENF22R2MMW Zelio Timer Relay - Modular

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Characteristics 5 TeSys k contactors and reversing contactors

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

08/07/2015

02/11/2015

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

02/11/2015

22/10/2012

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Electronic timer CT-MFS.21

08/07/2015

Zelio Control Measurement Relays

Protection components

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Electronic timer CT-SDD.22

05/09/2012

PART NUMBERING SYSTEM

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electronic timer CT-SDS.22

Protection components

24/07/2012

02/11/2015

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type CP-S, CP-C & CP-A Switch mode

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Multi-voltage Multi-function. Wiring diagram (without control signal)

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

27/04/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

11/03/2013

02/11/2015

Type Nominal voltage (V) Code HSV V

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-TGD.22

02/11/2015

Electronic timers CT-S range Selection and ordering details

References 1 for asynchronous motors 1

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Solid-state Timer H3DS

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts


Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

PART NUMBERING SYSTEM

Three-phase monitoring relays

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Transcription:

Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Complementary Discrete output type Contacts material Width pitch dimension [Us] rated supply voltage Voltage range Connections - terminals Tightening torque Setting accuracy of time delay Nov 4, 2018 Zelio Time Industrial timing relay 2 C/O RE7 A C D Di H Qg Qt W 0.05 s...300 h Relay 90/10 silver nickel contacts 22.5 mm 24...240 V AC/DC at 50/60 Hz 0.85...1.1 Us Screw terminals, clamping capacity: 2 x 1.5 mm² flexible with cable end Screw terminals, clamping capacity: 2 x 2.5 mm² flexible without cable end 0.6...1.1 N.m Repeat accuracy +/- 0.2 % Temperature drift Voltage drift Minimum pulse duration Reset time Maximum switching voltage Mechanical durability [Ith] conventional free air thermal current +/- 10 % of full scale < 0.07 %/ C < 0.2 %/V 20 ms 50 ms 250 V AC/DC 20000000 cycles 8 A [Ie] rated operational current <= 2 A DC-13 24 V at 70 C conforming to IEC 60947-5-1/1991/VDE 0660 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Minimum switching capacity Input voltage Maximum switching current Input compatibility Potentiometer characteristic Marking <= 3 A AC-15 at 70 C conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.1 A DC-13 250 V at 70 C conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.2 A DC-13 115 V at 70 C conforming to IEC 60947-5-1/1991/VDE 0660 12 V / 10 ma < 60 V X1Z2 terminal(s) < 60 V Y1Z2 terminal(s) 1 ma X1Z2 terminal(s) 1 ma Y1Z2 terminal(s) Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage Supply disconnection value Operating position 3/4 wires sensors PNP/NPN without internal load 50 m X1Z2 terminal(s) 3/4 wires sensors PNP/NPN without internal load 50 m Y1Z2 terminal(s) Linear 47 kohm (+/- 20 %), 0.2 W, cable length: 25 m Z1Z2terminal(s) CE 250 V between contact circuit and control inputs IEC certified 250 V between contact circuit and power supply IEC certified 300 V between contact circuit and control inputs CSA certified 300 V between contact circuit and power supply CSA certified > 0.1 Uc Any position without derating Surge withstand 2 kv conforming to IEC 61000-4-5 level 3 Power consumption in VA Power consumption in W Peak current Terminal description Height Width Depth Product weight 2 VA 24 V 6 VA 240 V 2.5 VA 48 V 3.2 VA 110 V 1 W 48 V 2 W 24 V 2 W 240 V 3.2 W 110 V 0.001 ka for 30 s on energisation (15-16-18)OC_OFF (25-26-28)OC_OFF (A1-A2)CO (X1)UNUSED (Y1)UNUSED (Z1)UNUSED (Z2)UNUSED 78 mm 22.5 mm 80 mm 0.15 kg Environment Immunity to microbreaks 3 ms Standards EN/IEC 61812-1 Product certifications CSA GL UL Ambient air temperature for storage -40...85 C Ambient air temperature for operation -20...60 C Relative humidity 15...85 % (3K3) conforming to IEC 60721-3-3 Vibration resistance 0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) IP50 (housing) Pollution degree 3 conforming to IEC 60664-1 Dielectric strength Non-dissipating shock wave 2.5 kv 4.8 kv Resistance to electrostatic discharge 6 kv (in contact) conforming to IEC 61000-4-2 level 3 8 kv (in air) conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 2

Resistance to fast transients 2 kv conforming to IEC 61000-4-4 level 3 Disturbance radiated/conducted CISPR 11 group 1 - class A CISPR 22 - class A Contractual warranty Warranty period 18 months 3

Dimensions Drawings Width 22.5 mm Rail Mounting Screw Fixing 4

Connections and Schema Internal Wiring Diagram 5

Connections and Schema Recommended Application Wiring Diagram Start on Energisation 1 Supply 2 12 48 V 3 24 V 6

Connections and Schema Recommended Application Wiring Diagram Start by External Control 1 Supply 2 12 48 V 3 24 V 7

Connections and Schema Recommended Application Wiring Diagram External Control of Partial Stop 1 Supply 2 12 48 V 3 24 V 8

Connections and Schema Control of Several Relays Control of several relays with a single external control contact 9

Connections and Schema Connection of Potentiometer 10

Connections and Schema Connection Precautions WARNING UNEXPECTED EQUIPMENT OPERATION No galvanic isolation between supply terminals and control inputs. Failure to follow these instructions can result in death, serious injury, or equipment damage. 11

Performance Curves Performance Curves A.C. Load Curve 1 Electrical durability of contacts on resistive loading millions of operating cycles X Y Current broken in A Millions of operating cycles A.C. Load Curve 2 Reduction factor k for inductive loads (applies to values taken from durability curve 1). X Power factor on breaking (cos ϕ) Y Reduction factor k Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore becomes:1.5 10 6 operating cycles x 0.6 = 900 000 operating cycles. 12

D. C. Load Limit Curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 13

Technical Description Function A : Power on Delay Relay Description The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 14

Technical Description Function C : Off-Delay Relay with Control Signal Description After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 15

Technical Description Function D : Symmetrical Flasher Relay (Starting Pulse Off) Description Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 16

Technical Description Function Di : Symmetrical Flasher Relay (Starting Pulse On) Description Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 17

Technical Description Function H : Interval Relay Description On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/ their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 18

Technical Description Function Qg: Star-Delta Timing Description Timing for star-delta starter with contact for switching to star connection. Function: 1 Output 19

Technical Description Function Qt: Star-Delta Timing Description Timing for star-delta starter with double On-delay period. Function: 1 Output 20

Technical Description Function W : Interval Relay with Control Signal Off Description After power-up and opening of the control contact, the output(s) close(s) for a timing period T. At the end of this timing period the output(s) revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). 21

Technical Description Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/R2 2 timed outputs R2 inst.the second output is instantaneous if the right position is selected T Timing period Ta - Adjustable On-delay Tr - Adjustable Off-delay U Supply is replaced by: Relay Output RE22R2MYMR Multi-function Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Qty 1 Reason for Substitution: End of life Substitution date: 18 August 2016 22