Alternated duty cycle control method for half-bridge DC-DC converter

Similar documents
A New Soft Switching PWM DC-DC Converter with Auxiliary Circuit and Centre-Tapped Transformer Rectifier

NEW microprocessor technologies demand lower and lower

IN THE high power isolated dc/dc applications, full bridge

BIDIRECTIONAL CURRENT-FED FLYBACK-PUSH-PULL DC-DC CONVERTER

Cost effective resonant DC-DC converter for hi-power and wide load range operation.

A Novel Bridgeless Single-Stage Half-Bridge AC/DC Converter

MODERN switching power converters require many features

Novel Soft-Switching DC DC Converter with Full ZVS-Range and Reduced Filter Requirement Part I: Regulated-Output Applications

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India.

Simulation and Analysis of Zero Voltage Switching PWM Full Bridge Converter

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter

FOR THE DESIGN of high input voltage isolated dc dc

INSULATED gate bipolar transistors (IGBT s) are widely

Design and analysis of ZVZCS converter with active clamping

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

Simplified loss analysis and comparison of full-bridge, full-range-zvs DC-DC converters

Design Consideration for High Power Zero Voltage Zero Current Switching Full Bridge Converter with Transformer Isolation and Current Doubler Rectifier

IN A CONTINUING effort to decrease power consumption

Investigation of DC-DC Converter Topologies for Future Microprocessor

A High Efficient DC-DC Converter with Soft Switching for Stress Reduction

Self-oscillating Auxiliary Medium Open Loop Power Supply Deploying Boost EIE Converter

PARALLELING of converter power stages is a wellknown

Maximum Power Extraction from A Small Wind Turbine Using 4-phase Interleaved Boost Converter

Simulation Comparison of Resonant Reset Forward Converter with Auxiliary Winding Reset Forward Converter

Exclusive Technology Feature. Simple Control Method Tames Flux Saturation In High-Frequency Transformer-Link Full-Bridge DC-DC Converters

CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER

Analysis, design and implementation of an improved two-switch zero-current zero-voltage pulse-width modulation forward converter

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

IN recent years, the development of high power isolated bidirectional

TELECOMMUNICATION dc dc brick converters with

One-Cycle Control of Interleaved Buck Converter with Improved Step- Down Conversion Ratio

DC-DC Resonant converters with APWM control

Comparison and Simulation of Full Bridge and LCL-T Buck DC-DC Converter Systems

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

A Color LED Driver Implemented by the Active Clamp Forward Converter

A New Active Soft Switching Technique for Pulse Width Modulated Full Bridge DC-DC Converters

Comparative Analysis of Power Factor Correction Techniques for AC/DC Converter at Various Loads

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

A New ZVS Bidirectional DC-DC Converter With Phase-Shift Plus PWM Control Scheme

TYPICALLY, a two-stage microinverter includes (a) the

High Step-Up DC-DC Converter for Distributed Generation System

Soft Switched Resonant Converters with Unsymmetrical Control

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

THE flyback converter represents a widespread topology,

A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter Qin, Zian; Pang, Ying; Wang, Huai; Blaabjerg, Frede

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

Analysis and Design Considerations of a Load and Line Independent Zero Voltage Switching Full Bridge DC/DC Converter Topology

An Application of Soft Switching for Efficiency Improvement in ZVT-PWM Converters

Narasimharaju. Balaraju *1, B.Venkateswarlu *2

BIDIRECTIONAL dc dc converters are widely used in

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

GENERALLY, a single-inductor, single-switch boost

Proceedings of the 7th WSEAS International Conference on CIRCUITS, SYSTEMS, ELECTRONICS, CONTROL and SIGNAL PROCESSING (CSECS'08)

THE TWO TRANSFORMER active reset circuits presented

Modular Multilevel Dc/Dc Converters with Phase-Shift Control Scheme for High-Voltage Dc-Based Systems

DC-DC Transformer Multiphase Converter with Transformer Coupling for Two-Stage Architecture

RECENTLY, newly emerging power-electronics applications

JABER A. ABU QAHOUQ Tel: (407) (H) (407) (W)

Voltage Fed DC-DC Converters with Voltage Doubler

Chapter 6 ACTIVE CLAMP ZVS FLYBACK CONVERTER WITH OUTPUT VOLTAGE DOULER

THE converter usually employed for single-phase power

새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터

Improvements of LLC Resonant Converter

A SINGLE STAGE DC-DC CONVERTER FEASIBLE TO BATTERY CHARGING FROM PV PANELS WITH HIGH VOLTAGE STEP UP CAPABILITY

Zero voltage switching active clamp buck-boost stage Cuk converter

NOWADAYS, several techniques for high-frequency dc dc

A Series-Resonant Half-Bridge Inverter for Induction-Iron Appliances

SIMULATION STUDIES OF HALF-BRIDGE ISOLATED DC/DC BOOST CONVERTER

Presentation Content Review of Active Clamp and Reset Technique in Single-Ended Forward Converters Design Material/Tools Design procedure and concern

THE vehicle industries are nowadays working to reduce

A New Three-Phase Interleaved Isolated Boost Converter With Solar Cell Application. K. Srinadh

Analysis and Design of Soft Switched DC-DC Converters for Battery Charging Application

ENTIRE LOAD EFFICIENCY AND DYNAMIC PERFORMANCE IMPROVEMENTS FOR DC-DC CONVERTERS

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

Step-Up Switching-Mode Converter With High Voltage Gain Using a Switched-Capacitor Circuit

Novel Zero-Current-Switching (ZCS) PWM Switch Cell Minimizing Additional Conduction Loss

Simulation of a novel ZVT technique based boost PFC converter with EMI filter

Comparison Between two Single-Switch Isolated Flyback and Forward High-Quality Rectifiers for Low Power Applications

A Lossless Clamp Circuit for Tapped-Inductor Buck Converters*

DC-DC Converter with Coupled-Inductors Current-doubler

AN IMPROVED ZERO-VOLTAGE-TRANSITION INTERLEAVED BOOST CONVERTER WITH HIGH POWER FACTOR

DC-to-DC Converter for Low Voltage Solar Applications

A THREE-PHASE HIGH POWER FACTOR TWO-SWITCH BUCK- TYPE CONVERTER

IN APPLICATIONS where nonisolation, step-down conversion

Three-phase soft-switching inverter with coupled inductors, experimental results

SIMULATION OF SOFT SWITCHING BASED RESONANT DC-DC CONVERTER

A New Interleaved Three-Phase Single-Stage PFC AC-DC Converter with Flying Capacitor

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

Conventional Single-Switch Forward Converter Design

A New Soft Recovery PWM Quasi-Resonant Converter With a Folding Snubber Network

A Novel Concept in Integrating PFC and DC/DC Converters *

Non-isolated DC-DC Converter with Soft-Switching Technique for Non-linear System K.Balakrishnanet al.,

466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY A Single-Switch Flyback-Current-Fed DC DC Converter

ACEEE Int. J. on Control System and Instrumentation, Vol. 02, No. 02, June 2011

THE classical solution of ac dc rectification using a fullwave

A Bidirectional Series-Resonant Converter For Energy Storage System in DC Microgrids

Integrated Circuit Approach For Soft Switching In Boundary-Mode Buck Converter

A Novel Soft Switching Lcl-T Buck Dc Dc Converter System

A New 3-phase Buck-Boost Unity Power Factor Rectifier with Two Independently Controlled DC Outputs

Transcription:

HAIT Journal of Science and Engineering B, Volume 2, Issues 5-6, pp. 581-593 Copyright C 2005 Holon Academic Institute of Technology CHAPTER 3. CONTROL IN POWER ELEC- TRONIC CIRCUITS Alternated duty cycle control method for half-bridge DC-DC converter Jaber A. Abu-Qahouq 1,2,HongMao 3, and Issa Batarseh 1, 1 Department of Electrical and Computer Engineering, University of Central Florida, Orlando, FL 32816, USA 2 Intel Corporation, Hillsboro, OR 97124, USA 3 Division of Emerson Network Power, Astec Power Advanced Technology, Andover, MA 01810, USA Corresponding author: batarseh@mail.ucf.edu Received 1 July 2005, accepted 24 August 2005 Abstract A control method, namely, Alternated Duty Cycle (ADC) control, is presented in this paper. This method can achieve soft-switching for at least one switch of the two half-bridge switches. When soft-switching can be achieved only for one switch, ADC control alternates the softswitching realization between the two switches so that each switch will be soft-switched during half of the time and hard-switched during the other half, keeping equal power losses distribution between the switches for better thermal management. Moreover, any asymmetry in the duty cycle will not cause asymmetric components stresses or transformer DC bias when ADC control is used. Theoretical analysis and implementation are presented along with experimental results. 1 Introduction Half-bridge topology [1-3] can be a good candidate for high power density DC-DC conversion, especially in those applications that use Point-Of-Load 581

(POL) DC-DC converters for present and future generation of ICs (Integrated Circuits). This is because of several reasons including structure simplicity, lower number of switches, lower isolation transformer primary side turns since half of the input voltage is applied to the transformer windings, and possibility to achieve soft-switching with the appropriate control [1-3]. There are two main conventional control schemes used in the half-bridge topology. One is the conventional symmetric PWM control and the other is the asymmetric (complementary) control [1,2] where two driving signals are complementarily generated. The switching frequency continues to increase mainly to reduce the size and cost of passive components and to improve the dynamic performance [3-4]. Hence, soft-switching techniques become more desirable in order to reduce the increased switching losses and switches body diodes reverse recovery losses at increased switching frequencies [1-3,5,6]. When the conventional symmetric control is used for a half-bridge, its two switches operate at hard-switching, while when the asymmetric (complimentary) control is used, the two half-bridge switches operate at softswitching, but unfortunately, causing asymmetric stresses on the converter components which is not desirable especially for wide input voltage range, say 35V 75V or 300V 400V [1-3]. Moreover, the DC gain is not linear which degrades the converter performance. In this paper, a control method, namely, Alternated Duty Cycle (ADC) control, is presented. This method can achieve soft-switching for at least one switch of the two half-bridge switches. When soft-switching is only achieved for one switch, ADC control alternates the soft-switching realization between the two switches so that each switch will be soft-switched during half of the time and hard-switched during the other half, keeping equal power losses distribution between the switches. Moreover, any asymmetry in the duty cycle will not cause asymmetric components stresses when ADC control is used. The next section briefly presents the Alternated Duty Cycle (ADC) control and its principle of operation followed by a theoretical analysis and comparison in Section 3. Section 4 discusses the experimental work. The conclusion is given in Section 5. 2 Alternated duty cycle control and principle of operation This section briefly discusses what it meant by the Alternated Duty Cycle (ADC) control before going into the details and ADC configurations descrip- 582

Figure 1: Half-bridge topology with current doubler secondary side. tion when applied to half-bridge converter, such as the one shown in Fig. 1 along with its modulation scheme and modes of operation. 2.1 Basic concept of the alternated duty cycle control scheme Let us assume two arbitrary waveforms, C a and C b, generated from the PWM controller for the half-bridge as shown in Fig. 2, where T s is the switching cycle period, D is the switching duty cycle or ratio, and m is a real number (can be floating number). When m =1, C a and C b become the control signals of asymmetric control, and when m =(1 D)/D, C a and C b become the control signals of symmetric control. C 1 and C 2 in Fig. 2 are the ADC control waveforms to drive S 1 and S 2, respectively, where C a and C b ON times are alternated between the two switches so that S 1 will be turned ON by C a in the first cycle and by C b in the following cycle and vise versa for S 2, resulting in C 1 and C 2. When C a and C b are the asymmetric control signals (at m =1),the resulting ADC control signals C 1 and C 2 will result in symmetric voltages across the half-bridge capacitors C S1 and C S2 even though the duty cycle is asymmetric since the average duty cycles of C 1 and C 2 are symmetric. This will result in a converter that works but, unfortunately, lacks the ability to be regulated for the output voltage at different input and output conditions. The reason for this phenomenon is that in order to have the regulation ability in the half-bridge converter, switching dead time period is required as in the symmetric control or asymmetry is required as in asymmetric control, which 583

is lost in this case. Under this condition, when m =1, this topology is suitable for applications where intermediate DC transformer is required, and regulation is not required. Therefore, m will be larger than one resulting in losing the soft-switching operation for one switch. However, it is interesting to note that the softswitching will be alternated between the two half-bridge switches, i.e., S 1 willbesoft-switchedinthefirstcycleandhardswitchedinthefollowing cycle and so on, and vise versa for S 2. When m =(1 D)/D, symmetric (equal) duty cycles are achieved for C a and C b and hence for C 1 and C 2. However, in the ADC control, equal duty cycle is not required since it will not affect the symmetry of the converter. Figure 2: Generalized alternated duty cycle control waveforms. 2.2 ADC PWM modulation Different modulation schemes can be adapted to generate the ADC control signals. ADC modulation can be digital modulation or analog modulation. In digital modulation case, it is generally simple to generate any, even complicated, control signals such as those required for ADC control. For the 584

case of analog modulation for ADC control, Fig. 3 shows a possible modulation approach for the realization of ADC PWM control. V sawtooth is the modulation carrier waveform, and V c is the main control voltage derived from the voltage or current controller/compensator, from which the other control voltage V p mv c is generated, where V p is the peak voltage of the Figure 3: A PWM modulation scheme for Alternated Duty Cycle control: (a) modulation circuit, and (b) modulation waveforms. 585

carrier V sawtooth. By modulating V c and V p mv c, the signals C a and C b can be generated, from which the final half-bridge switches control signals, C 1 and C 2, are then generated using a logic stage that consists of D-flip-flops, AND, and OR logic gates, as shown in Fig. 3. 2.3 Modes of operation Figure 4 shows the theoretical main switching waveforms of the ADC controlled half-bridge of Fig. 1. The main modes of operation can be summarized as follows: Mode 1 (t 0 <t<t 1 ): S 1 is ON and S 2 is OFF during this mode starting t = t 0, and the input power is being delivered to the output through L 1 and SR 2 which is also ON during this mode (SR 1 is OFF). During this mode, L 1 is charged and L 2 freewheels (discharges) through SR 2.Thismodelast for a duration of (1 md)t s,where1 <m<1/d. Figure 4: ADC controlled half-bridge main switching waveforms. 586

Mode 2 (t 1 < t < t 2 ): S 1 is turned OFF at t = t 1 and SR 1 and SR 2 are turned ON, causing the primary current I P to charge S 1 junction capacitance C j1 and discharge C j2. When the secondary side switches SR 1 and SR 2 start to freewheel, the isolation transformer leakage inductance L K and the primary side switches junction capacitances, C j1 and C j2, oscillate on the primary side. Mode 3 (t 2 <t<t 3 ):Att = t 2, S 1 is turned ON again. This mode is similar to Mode 1 except that it lasts for duration of DT s. Mode 4 (t 3 <t<t 4 ): S 1 is turned OFF at t = t 3, causing the primary current I P to charge C j1 and discharge C j2. During this Mode, the reflected secondary inductor current dominates the primary current I P. Therefore, the voltage across C j2 may be discharged to zero, which provides wide Zero- Voltage-Switching (ZVS) condition for S 2. Mode 5 (t 4 <t<t 5 ): At t = t 4, S 2 is turned ON with ZVS. SR 1 is ON and SR 2 is OFF. During this mode and the input power is being delivered to the output through L 2 and SR 1. L 2 is charged and L 1 freewheels (discharges) through SR 1. This mode last for duration of (1 md)t s. Figure 5: Voltage gain versus duty cycle for different values of m. 587

Mode 6 (t 5 <t<t 6 ): S 2 is turned OFF at t = t 5 and SR 1 and SR 2 are turned ON, causing the primary current I P to charge C j2 and discharge C j1. When the secondary side switches SR 1 and SR 2 start to freewheel, the isolation transformer leakage inductance L K and the primary side switches junction capacitances, C j1 and C j2, oscillate on the primary side. Mode 7 (t 6 <t<t 7 ):Att = t 6, S 2 is turned ON again. This mode is similar to Mode 5 except that it lasts for duration of DT s. Mode 8 (t 7 <t<t 8 ): S 2 is turned OFF at t = t 7, causing the primary current I P to charge C j1 and discharge C j2. During this Mode, the reflected secondary inductor current dominates the primary current I P. Therefore, the voltage across C j1 may be discharged to zero, which provides wide ZVS condition for S 1. After this, Mode 1 starts again by turning ON S 1 with ZVS. From Fig. 4 and the modes of operation analysis, it can be noticed that when the falling edge of one switch gate signal is close to the rising edge of the rising edge of the other switch, ZVS is achieved for the other switch by utilizing the leakage inductor stored energy. ZVS is achieved alternatively for the two half-bridge switches. 3 Theoretical analysis and comparison It can be shown by simply applying the volt-second-balance across the output inductors that the voltage gain equation for the ADC controlled halfbridge is given by: V o 1 D(m 1) = V g 2 which means that: or V o V in = 1 4n [1 D(m 1)], 1 <m< 1 D (1) D = V g 2V o V g (m 1). (2) Fig. 5 shows the voltage gain versus duty cycle for different values of m. The output current ripple equation is given by: I o = 2 V o L f s D(m 1) = 2V o V g V g 2V o L f s, (3) V g = V in for ADC controlled half-bridge. 2n Fig. 6 shows the output current ripple versus duty cycle from Eq. (3) for V o =3.3V, L =2µH, and f s = 400kHz at different m values. It can 588

589

Figure 6: Output current ripple versus duty cycle at different m values for V o =3.3V, L =2µH, and f s = 400kHz. Figure 7: Photo of the half-bridge DC-DC converter prototype. 590

Figure 8: Experimental waveforms: (a) S 1 and S 2 driving signals, (b) isolation transformer primary side voltage V AB and S 2 driving signals, (c) isolation transformer primary side voltage V AB and S R1 and S R2 drain-to-source voltages. 591

be noticed that as m gets smaller and approaches one, the output current ripple gets smaller and reduced. Table 1 shows some of the characteristics/stresses of the ADC controlled half-bridge compared to other half-bridge control schemes. 4 Experimental work A 100W half-bridge prototype of the type of in Fig. 1 and having nominal input voltage V in =48V and output voltage V o =3.3V, was built in the laboratory for verification and evaluation and shown in the photo of Fig. 7. The switching frequency is 400kHz and with output inductors of L 1 = L 2 = 500nH. The primary side switches S 1 and S 2 are Si7456DP each. At the secondary side, synchronous rectifiers (SRs) are used, two Si7892DP paralleled in each of the two current doubler channels. The prototype is ADC controlled with equal duty cycles (m =(1 D)/D). Fig. 8 shows some experimental waveforms. Fig. 8a shows the two half-bridge switches ADC gate driving while Fig. 8b shows the isolation transformer primary side voltage with one of the switches driving signal were ZVS is achieved alternatively between the half-bridge two switches. Fig. 8c shows the isolation transformer primary side voltage along with the waveforms of the SRs drain-to-source voltages. The experimental waveforms agree with the theoretical ones. Fig. 9 shows the prototype measured efficiency curve. Figure 9: Experimental efficiency curve. 592

5 Conclusion The Alternated Duty Cycle (ADC) control is presented in this paper. This method can achieve soft-switching for at least one switch of the two halfbridge switches. When soft-switching is achieved only for one switch, ADC control alternates the soft-switching realization between the two switches so that each switch will be soft-switched during half of the time and hardswitched during the other half, keeping equal power losses distribution between the switches and resulting in good thermal management. Moreover, the any asymmetry in the duty cycle will not cause asymmetric components stresses, DC transformer bias, or nonlinear DC gain when ADC control is used. Description and theoretical analysis and implementation were presented along with experimental results. This work is supported by ASTEC Power. References [1] J. Sebastian, J.A. Cobos, O. Garcia, and J. Uceda, IEEE Power Electronics Specialists Conference, PESC 95, p.1229 (1995). [2] P. Imbertson and N. Mohan, IEEE Transaction on Power Electronics 29, 121 (1993). [3] Y. Panov and M. Jovanovic, IEEE Fourteenth Annual Applied Power Electronics Conference and Exposition, APEC 99, vol. 1, p.545 (1999). [4] J.A. Abu-Qahouq, Hong Mao, and I. Batarseh, IEEE 33-rd Annual Power Electronics Specialists Conference, PESC 02, vol. 4, p.1576 (2002). [5] R. Redl, N.O. Sokal, and L. Balogh, IEEE Power Electronics Specialists Conference PESC 95, p.162 (1990). [6] G.A. Karvelis, M.D. Manolarou, P. Malatestas, and S.N. Manias, IEE Proc. Electric Power Applications 148, 419 (2001). 593