OCULUS Easygraph. Topographer. We focus on progress

Similar documents
OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

OCULUS Keratograph 4. Topographer. We focus on progress

OCULUS ImageCam 2. Slit lamp documentation. We focus on progress

OCULUS Keratograph 5M Topographer

OCULUS Keratograph 5M Topographer

OCULUS Pentacam AXL Always an Axial Length Ahead

OCULUS Binoptometer 4P

The New Corvis ST. Evaluation of corneal biomechanical response, tonometry and pachymetry. Biomechanical Response

OCULUS Twinfield 2. Perimeter. We focus on progress

OCULUS Easyfield. Perimeter. We focus on progress

ATLAS Corneal Topography System

(495) (495)

Refractive Power / Corneal Analyzer. OPD-Scan III

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

We focus on progress OCULUS CENTERFIELD 2

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS


KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

The War against Corneal Warpage

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Wave-Front Analyzer KR-1W

Aberrometry in Clinical Practice

ClearKone Restoring vision. Changing lives.

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Optical Coherence Tomography Retina Scan Duo

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.

Catalogue No. 109, valid as of May The Full HD Video Colposcope

Keratoconus contact lenses

Instruments Commonly Used For Examination of the Eye

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Headline. IOLMaster. Subline. The gold standard in biometry

REF KERATRON. The Standard in Corneal Topography

Dynamic Ophthalmic Software for today s market. Automated Grading System

Optometrist Private ophthalmologists

case report Scleral lens fit based on OCT data

family of lens designs fitting guide ICD is Exclusively Manufactured In

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

The Aberration Structure of the Keratoconic Eye

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Innovation and Quality Made in Germany

The TRIumph of Excellence

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Trouble Shooting Guide for Ortho-K lenses

Auto Ref / Keratometer ARK-560A / 530A / 510A

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

Principles and clinical applications of ray-tracing aberrometry (Part II)

CONSOLE ADVANCE The He art of Your FDR/ FCR System

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Auto Ref/Kerato/Tonometer TONOREF 2

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

CR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Fitting Manual Use with kerasofttraining.com

Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef

Advanced Fitting Guide

Cutting-edge image quality

Fitting Manual Use with

ERK-9000 Auto Ref/Kertometer

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia

you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

Chairside digital. Imaging Plate System

Keeler Direct Ophthalmoscopes

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Technicians & Nurses Program

Neurosurgery with ultrasonic technology by Söring: fine preparation and effective dissection

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Using Orthotool Software

Going beyond the surface of your retina

MEDICAL & LIFE SCIENCES

INTERFEROMETER VI-direct

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

Straightforward Vestibular testing

TRC-NW400 Non-Mydriatic Retinal Camera

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

Optical Biometer AL-Scan

SLIT LAMP BQ 900 Sophisticated microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

Wide Angle Ophthalmoscope Instructions

Optical Connection, Inc. and Ophthonix, Inc.

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l

Transcription:

OCULUS Easygraph Topographer We focus on progress

The Compact Corneal Topographer at a Glance Corneal topographer with built-in keratometer Comfortable, hygienic working distance reduces the influence of positioning tolerances Quick 3D alignment with auto-release to ensure highest accuracy and repeatability Sagittal (axial) and tangential (local) curvature [mm] and power [dpt] maps Refractive power map using Snell s law of refraction Elevation maps Zernike and Fourier analysis Cornea diameter (HWTW) Comparison display and big camera image Easy to mount on any conventional slit lamp Easy to use sophisticated user interface in Windows environment USB interface to PC/Laptop with network compatible software Overview and 3D Display The overview display shows different evaluations which together provide a quick overview of corneal topography. The coloured topography map describes the corneal curvature of the anterior surface. The measured local radii of curvature are displayed in colour. Abnormalities can be measured directly in the camera image. Important results such as central radii, corneal astigmatism, corneal diameter and eccentricity are displayed automatically. Compare Different Examinations Regular follow-up examinations are essential for ophthalmologists as well as contact lens fitters. The Easygraph has three different displays for comparing examinations over time, making it easier to detect corneal changes or abnormalities (e.g. keratoconus). In addition the displays show changes in corneal refractive power and allow documentation of refractive changes brought about by refractive surgery or from wearing Ortho-K lenses.

OCULUS Easygraph So Small and Yet a Topographer Small, but Efficient As a Big One Wanting to work with a video keratometer in spite of limited space? Then the OCULUS Easygraph is what you re looking for. Equipped with proven measurement and device technology for contact lens fitting as well as precise and reliable diagnostics, the Easygraph has all it takes to be a real topographer, and one worthy of its big brother, the OCULUS Keratograph. All Important Parameters at a Glance Easy to Adapt The Easygraph can be easily attached to any conventional slit lamp with minimum additional space requirements and positioned for quick, automatic measurements without touching the eye. The OCULUS Easygraph in life size

Small but Perfect Optional Software Extensions at a Glance Contact Lens Fitting Applications: Immediate suggestion of the best contact lens fitting Huge pre-programmed and expandable contact lens database Real fluorescein image simulation Reduced chair time Refractive comparison module for Ortho-K lenses Details: The contact lens fitting module suggests the best fitting contact lens. Different contact lenses types and geometries can be compared using fluorescein image simulation. Moreover the refractive comparison module helps in selecting Ortho-K lensesas well as objectively monitoring corneal refractive power changes. OxiMap Visualising Oxygen Transmissibility for Professional Patient Consultation. The cornea needs oxygen, and a good oxygen supply is therefore fundamental for the comfort of contact lens wearers. New materials used for soft contact lenses offer excellent oxygen transmissibility. This can be demonstrated using the new OCULUS OxiMap display. You can easily show these colour maps to your patients in order to better explain them your contact lens recommendations. OxiMap shows the oxygen transmissibility of contact lenses on a colour scale to depict the current international recommendations for daily, extended and continuous wear. > Oxygen transmissibility of -3.00 D and -10.00 D contact lenses of identical type

Keratoconus Screening Eight different indices are calculated based on an analysis of the anterior corneal surface. Keratoconus suspects as well as advanced keratoconus stages are detected and classified. Side-by-side presentation of different examinations facilitates follow-up. Zernike Analysis Zernike Analysis provides a means of describing irregularities of the cornea precisely. An elevated aberration coefficient indicates a decline in retinal image quality. Zernike Analysis makes it possible to determine the exact position of the keratoconus apex. OCULUS Floating License Key Activate Functions Exactly as you Need Them The Floating License Key activates optional functions in the device software. You only require one Floating License Key which centrally manages all licenses in a local network. You can decide which additional functions are to be allocated to each device. Efficiency Through Networking The OCULUS patient data management enables you to merge all OCULUS devices in a local network. It allows you to network with external data management systems (EMR) to optimises your workflows. Devices with or without DICOM interface can be connected. Subtasks can be easily delegated and datasets can be centrally managed. Consultation Examination room Examination room Server (with/without DICOM) Patient check-in

Technical Data Oculus Easygraph Accuracy ± 0.2 D Reproducibility ± 0.2 D Number of rings 22 Working distance 1.6 (40 mm) Number of measurement points 22,000 Dimensions: H x D x W 8.4 x 4.1 x 4.6 (214 x 103 x 116 mm) Weight (measuring unit) 1lb 6 oz (630 g) Power supply unit Input: 100-240 V Output: 5 V / 1 A Minimum PC requirements Compatibility Processor: Intel Core i3 or better, 4 GB main memory, Hard disk: 500 GB and up, graphic card: Intel HD Graphics 2000 or better, Recommended screen resolution: 1920 x 1080 (full-hd) Operating system: Windows XP or above 64 bit Windows compatible in accordance with Medical Device Directive 93/42/EEC Ø 119 mm [4.69 inches] 101.9 mm [4.01 inches] 215.5 mm [8.48 inches] WWW.OCULUS.DE Oculus is certified by TÜV according to DIN EN ISO 13485/DIN EN ISO 9001 37 mm [1.46 inches] 36 mm [1.42 inches] 92 mm [3.63 inches] > Slit lamp adapter included as standard accessory OCULUS Optikgeräte GmbH Postfach 35549 Wetzlar GERMANY Tel. +49-641-2005-0 Fax +49-641-2005-295 Email: export@oculus.de www.oculus.de OCULUS USA, sales@oculususa.com OCULUS Asia, info@oculus.hk OCULUS Czechia, oculus@oculus.cz OCULUS Iberia, info@oculus.es OCULUS Poland, biuro@oculus.pl Specifications and design are subject to change without notice and may vary depending on region. 04/0113/EN/Fr P/70620/EN