MODEL 3810/2 Line Impedance Stabilization Network

Similar documents
Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Model 3106 Double-Ridged Waveguide Horn

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Model 3116 Double-Ridged Waveguide Horn

Model 3110B Biconical Antenna

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

Model 3148 & Log-Periodic Dipole Array Antenna

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

200Amp AC Clamp Meter + NCV Model MA250

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

BROADBAND LINEAR AMPLIFIER Model P150

V1.3. TBLC08 50mH AC-LISN TBLC08

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

SAS-562B Active Loop Antenna Operation Manual

Instruction Manual Model Upconverter

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

SAS-563B Active Loop Antenna Operation Manual

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Operator s Manual. PP016 Passive Probe

Instruction Manual Model Upconverter

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

50 μh Line Impedance Stabilisation Network (AC LISN)

CBA 400M MHZ to 400 MHZ

TA MHz oscilloscope probe TA MHz oscilloscope probe

ELECTROSURGICAL UNIT ANALYZER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

PHV RO High Voltage Passive Probe. Instruction Manual

PKT 512A-RO High Impedance Passive Cable Divider

Instruction Manual Model M Switch, DPDT, Manual Select

VT1586A Rack Mount Terminal Panel Installation and User s Manual

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

TETRIS User's Guide. High Impedance Active Probe DO177-1

Bulk Current Injection Probe Test Procedure

Current Probe Fixture Instruction Manual

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

Broadband Step-Up Transformer. User Manual

Advanced Test Equipment Rentals ATEC (2832)

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Advanced Test Equipment Rentals ATEC (2832)

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

INSTRUCTION MANUAL LKG

Broadband Current Probe Series Operation Manual

Model CC4041. CC Series Amplifier. Installation and Use Manual

Autoranging Multimeter Extech EX503

BROADBAND'LINEAR'AMPLIFIER WITH'A±B'INPUTS'AND'DC5OFFSET Model&A400X

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

User Guide. Digital AC/DC Clamp Meter Model 38394

AC/DC Current Oscilloscope Probe Model SL261

Model 1791 VHF Radio User's Manual

User s Guide. Digital AC/DC Clamp Meter Model 38394

HTA125A/250A. Power Amplifiers. Installation & Use Manual

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

TDS-535 Tuned Dipole Set Operation Manual

Model 935A Current Source Operation Manual

Model 4007DDS. 7 MHz Sweep Function Generator

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

INSTRUCTION MANUAL. March 11, 2003, Revision 3

MICRO SERIES MONITORS

Broadband Current Probe Series Operation Manual

Operator s Manual. PP022 Passive Probe

TK 100 Probe Calibrator. Instruction Manual

400Amp True RMS AC Clamp Meter + NCV

Electrical Multimeter

USER'S MANUAL DMR-6700

Operator s Manual. PP017 and PP018 Passive Probes

TIA-952 Optical/Electrical Converter. Operating Instructions

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Classic Series Public Address Amplifiers C10 & C20 Models

SSR VL-12P-xC-NCS

DUAL%CHANNEL%LINEAR%AMPLIFIER %WITH%PHASE%INVERTER Model&A400DI

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AMP-13 OPERATOR S MANUAL

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Radio Remote Controls Manual K Series

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Instruction Manual CT-6 High Frequency AC Current Probe

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model CC4052. CC Series Amplifier. Installation and Use Manual

SAS-543 Biconical Antenna Operation Manual

Model 3142B BiConiLog Antenna

Model 7000 Low Noise Differential Preamplifier

EC Declaration of Conformity

Transcription:

EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047 Tel 512.835.4684 800.253.3761 Fax 512.835.4729 EUROPE Einsteinstrasse 35, D-82152 Planegg, Germany Tel 49 89 856 20 71 Fax 49 89 859 77 85

NOTICE: This product and related documentation must be reviewed for familiarization with safety markings and instructions before operation. SAFETY SYMBOL DEFINITIONS OR REFER TO MANUAL When product is marked with this symbol refer to instruction manual for additional information. OR HIGH VOLTAGE Indicates presence of hazardous voltage. Unsafe practice could result in severe personal injury or death. PROTECTIVE EARTH GROUND (SAFETY GROUND) Indicates protective earth terminal. You should provide an uninterruptible safety earth ground from the main power source to the product input wiring terminals, power cord, or supplied power cord set. CAUTION CAUTION Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. EQUIPOTENTIALITY Identifies the terminals, when connected together, to bring various parts of a system to the same potential, not necessarily being the earth (ground) potential, e.g. for local bonding. GENERAL SAFETY CONSIDERATIONS BEFORE POWER IS APPLIED TO THIS INSTRUMENT, GROUND IT PROPERLY through the protective conductor of the AC power cable to a power source provided with protective earth contact. Any interruption of the protective (grounding) conductor, inside or outside the instrument, or disconnection of the protective earth terminal could result in personal injury. WARRANTY BEFORE SERVICING: CONTACT EMCO - servicing (or modifying) the unit by yourself may void your warranty. If you attempt to service the unit by yourself, disconnect all electrical power before starting.there are voltages at many points in the instrument which could, if contacted, cause personal injury. Only trained service personnel should perform adjustments and/or service procedures upon this instrument. Capacitors inside this instrument may still be CHARGED even when instrument is disconnected from its power source. ONLY QUALIFIED PERSONNEL should operate (or service) this equipment. 1 0

Table of Contents GENERAL DESCRIPTION... 1 INSTALLATION AND APPLICATION... 2-3 SERVICE AND CLEANING... 4 SPECIFICATIONS... 5-6 ELECTRICAL... 5 MECHANICAL... 6 ENVIRONMENTAL... 6 SCHEMATIC... 7 DATA... 8 DECLARATION OF CONFORMITY... 9 1 1

GENERAL DESCRIPTION General Description The Model 3810/2 Line Impedance Stabilization Network is a twochannel low pass filter network designed to isolate the equipment under test from an external power source while steering any radio frequency signals from the power line to a 50 ohm port. The conducted emissions measurements may be made in accordance with regulatory compliance standards. A schematic of the Model 3810/2 is provided with the manual. The product has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. The instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition. 1

INSTALLATION AND APPLICATION Installation and Application The Line Impedance Stabilization Network (LISN) is nominally designed for a 10 ampere current capacity. Maximum line-to-line voltage must not exceed the voltage rating of the power outlet provided on the front panel of the LISN. Refer to the product specification sheet in this manual for the applicable maximum value. WARNING Overcurrent protection is not provided in the LISN. The LISN must be connected to a power mains which has the properly rated mains protection installed. The input power connection is made through an IEC-320 type power inlet. This three-wire input power connector is rated at 10 amperes maximum. In case of emergency, power can be removed from the LISN by removing the power connection at the LISN input. Alternately, a properly rated circuit breaker or switch which removes mains power from the unit can be installed in proximity to the LISN. WARNING This device is provided with a protective earthing ground integral to the power cord. The mains plug shall only be inserted in an outlet which incorporates a protective earth contact. Due to the high leakage current to ground inherent to this type of equipment, it is necessary to install a supplemental protective earthing wire from the protective earth terminal on the rear panel of the LISN to an appropriate earthing point of the power mains. This earthing point should be determined by an electrician authorized to do such work by appropriate code or law. Any interruption of the protective conductor inside or outside of the product is likely to make the product dangerous. Intentional interruption is prohibited. The supplemental ground wire is supplied with the LISN. 2

INSTALLATION AND APPLICATION The LISN is provided with an RF bonding stud on both the front and rear panels. The unit should be bonded to a ground plane in normal operation. The Equipment Under Test (EUT) is connected to the LISN through the panel mounted AC receptacle. The style of receptacle provided on the LISN is determined by the model specified. Standard output receptacle types are NEMA (type 5-15R), Schuko (type CEE 7/ 7) and British Standard (BS1363). This product is designed for use in Installation Category II and Pollution Degree II per IEC-1010 and IEC-664. When installing the LISN in a cabinet, the convection into and out of the product must not be restricted. The ambient temperature (outside the cabinet) must be less than the maximum operating temperature of the LISN by 4 o C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be used. Connection to the spectrum analyzer or EMI receiver is made using the type bnc connector on the front panel. The line to be monitored is selected using the two position selector switch located above the output AC receptacle. The line not selected is internally terminated into 50 ohms. Switching the monitor select switch between the two lines will not generate transients. When power is to be disconnected, remove the bnc connection to the measurement instrument first. CAUTION Although the LISN is provided with resistors to help bleed off high voltage transients, it is advisable to connect the input and output connectors to their proper power lines and loads before connecting the monitor port to the measurement instrument; otherwise, it is possible to damage the mixers or attenuators of the test instrument due to power surges or transients. A safety ground isolation choke selector switch, located on the front panel, switches the 1.6 mhy earth line choke IN and OUT of the safety ground circuit. The ground choke is designed and manufactured with sufficient capacity to conduct the maximum current rating of the LISN and at no time is the safety ground of the unit compromised. The earth line choke avoids a double rf ground connection (safety ground and measurement ground) in the conducted emissions test set-up. An artificial hand connection is provided on the front panel of the LISN. In conformance to EN55014 and BS800, the artificial hand is used to test those hand-held equipments which are provided without the earth connections. 3

SERVICE AND CLEANING Service And Cleaning The LISN has no user serviceable parts inside. To prevent electrical shock do not remove covers. Refer all servicing to qualified personnel. The unit is to be serviced at the factory. The factory address can be found on the serial number label on the product. To return the product for recalibration or service, use the original packaging or comparable materials. To clean the exterior of the cabinet, wipe with a damp cloth only. Do not clean the interior of the LISN. WARRANTY WARNING BEFORE SERVICING: CONTACT EMCO - Servicing (or modifying) the unit by yourself may void your warranty. If you attempt to service the unit by yourself, disconnect all electrical power before starting.there are voltages at many points in the instrument which could, if contacted, cause personal injury. Only trained service personnel should perform adjustments and/or service procedures upon this instrument. Capacitors inside this instrument may still be CHARGED even when instrument is disconnected from its power source. 4

SPECIFICATIONS Specifications ELECTRICAL Frequency range 9 khz - 30 MHz (VDE 0876 specified curve +/-20%) Network inductance 50 µh / 250 µh Network impedance 50 ohm Current rating 10 amps Maximum AC voltage 3810/2NM 125 VAC 60 Hz 3810/2SH 250 VAC 50 Hz 3810/2BS 250 VAC 50 Hz Outlet receptacle 3810/2NM NEMA 5-15R 3810/2SH Schuko CEE 7/7 3810/2BS British BS1363 Input connector IEC-320 type 3-wire inlet. 5

SPECIFICATIONS MECHANICAL Dimensions: Height Width Depth 4.9 in (124 mm) 8.6 in (218 mm) 15.0 in (381 mm) Weight 12.0 lb (5.4 kg) ENVIRONMENTAL Installation Indoor use only Altitude 15,000 ft (4,572 m) max Temperature 0 o C to 40 o C Relative Humidity 80% up to 31 o C decreasing linearly to 50% at 40 o C 6

SCHEMATIC NOTES 1. Resistance values shown in ohms 2. Ground choke select switch (S1) shown in IN position 3. Line monitor select switch (S2) shown in L2 (NTL) position 4. NEMA type output connector shown MODEL 3810/2 SCHEMATIC DIAGRAM LINE IMPEDANCE STABILIZATION NETWORK 7

DATA Data Graphs of the calibration data for each measurement port of the LISN are included in this manual. The graphs provide individual characterizations of both impedance and insertion loss data. Impedance is plotted in a semi-log graph where frequency is displayed on the horizontal from 9 khz to 30 MHz. The vertical of the graph has a range of 0 to 100 ohms and represents the measured impedance of the unit. The insertion loss is also plotted with frequency of the horizontal from 9 khz to 30 MHz. The vertical of the graph has a range of -9 db to 1 db and represents the measured insertion loss of the LISN. A Certificate of Calibration Conformance is provided with each Line Impedance Stabilization Network. 8

Warranty The Electro-Mechanics Company (EMCO) warrants that our products are free from defects in materials and workmanship for a period of two years from the date of shipment. If you notify us of a defect within the warranty period, we will at our option, either repair or replace those products which prove to be defective. If applicable, we will also recalibrate the product. There also will be no charge for warranty services performed at the location we designate. You must however, prepay inbound shipping costs and any duties or taxes. We will pay outbound shipping costs from a carrier of our choice, exclusive of any duties or taxes. You may request warranty services to be performed at your location, but it is our option to do so. If we determine that warranty services can only be performed at your location, you will not be charged for our travel related costs. This Warranty does not apply to: Normal wear of materials. Consumable items such as batteries, fuses, etc. Products which have been improperly installed, maintained, or used. Products which have been operated outside of specifications. Products which have been modified without authorization. Calibration of products, unless necessitated by defects. This warranty is exclusive. No other warranty, written or oral, is expressed or implied, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The remedies provided by this warranty are your sole and exclusive remedies. In no event are we liable for any damages whatsoever, including but not limited to, direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. NOTE Please contact our sales department for a Return Material Authorization Number before shipping equipment to us. 9