VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Similar documents
Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Better diagnosis and treatment all-in-one.

577 nm: The Preferred Wavelength

Headline. IOLMaster. Subline. The gold standard in biometry

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

KTP LASER. Photocoagulation System

MEL 80 Excimer Laser. When you want to see better performance

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

The Fastest Photocoagulator.

The pattern scanning multi-color photocoagulator that puts you in control

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

Instruments Commonly Used For Examination of the Eye

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Navigated Laser Therapy. A New Era in Retinal Disease Management

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

The First True Color Confocal Scanner

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

The First True Color Confocal Scanner on the Market

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

Impressive Wide Field Image Quality with Small Pupil Size

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

ATLAS Corneal Topography System

The First True-Color Wide-Field Confocal Scanner

Our vision is foresight

How do I acquire a high-quality scan on my CIRRUS HD-OCT? (Part 1 of 3 iris alignment)

Wide Angle Ophthalmoscope Instructions

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Lecture 2 Slit lamp Biomicroscope

Optical Coherence Tomography Retina Scan Duo

Introduction. Chapter Aim of the Thesis

introducing the M22 success made simple

Training Eye Instructions

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

CR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

OCULUS Keratograph 4. Topographer. We focus on progress

Light has some interesting properties, many of which are used in medicine:

Figure 1. Relative intensity of solar energy of different wavelength at the earth's surface.

SLIT LAMP BQ 900 Sophisticated microscopy

Litho DK30. Taking care of people, our masterpieces. State-of-the-art Desktop 30 W Holmium:YAG Laser. Surgery

VISIOMED Luminis A New Standard in Dermoscopy

Beautifully Crafted Slit Lamps

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

Xcel 255 & 455 Slit Lamps

PINXEL. Micro Needle Rf & Fractional Rf

K nk Valve 10 Year Limited Warranty

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

taccor Optional features Overview Turn-key GHz femtosecond laser

(a) Imaging Veins Superficial veins that are less than 3 mm deep can sometimes be seen as blue-green (often raised) areas of the skin.

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

SANO. Pinxel Introduction

Optical Coherence Tomography. RS-3000 Advance / Lite

BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS

Chapter 28: The FotoFacial RF Pro Galaxy TM

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Optical Coherence Tomography. RS-3000 Advance

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

Beautifully Crafted Slit Lamps

Optical Coherence Tomography. RS-3000 Advance / Lite

Keeler Direct Ophthalmoscopes

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

GE Healthcare. Essential for life. Senographe Essential Full-Field Digital Mammography system

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Kinder products for your most precious patients

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

NEWTOM GO 2D GREAT.VISION

MINISILK FT MINISILK FT MEDICINE AND AESTHETICS. DEKA Pulsed Light: Light, Compact, Extremely Versatile

Laser processing of materials. Laser safety

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

Leksell Neuro Generator

EYE ANATOMY. Multimedia Health Education. Disclaimer

Features. Applications. Optional Features

Sheep Eye Dissection

FOR PRECISE ASTIGMATISM CORRECTION.

Winter College on Optics: Trends in Laser Development and Multidisciplinary Applications to Science and Industry February 2013

Marine Invertebrate Zoology Microscope Introduction

How to Properly Select a Laser Power or Energy Sensor

ISO Ophthalmic optics and instruments Instruments to measure axial distances in the eye

MAKING SENSE OF SLIT LAMP SERVICING

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

CONTACT LENSES Discover a different world

CX-1 digital retinal camera mydriatic & non-mydriatic. Redefining true versatility.

Eyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

HEINE mini 3000 Pocket Diagnostic Instruments Now Available with LED Illumination

Optical Coherence Tomography. RS-3000 Advance / Lite

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging

Optical Coherence Tomography. RS-3000 Advance 2

Beautifully Crafted Slit Lamps.

Compact High Intensity Light Source

Transcription:

VISULAS Trion Treatment flexibility to the power of three Multicolor Photocoagulation Laser

Carl Zeiss: A pioneer in retinal therapy For many years, Carl Zeiss has fostered a culture of highest precision, quality and innovation in optical engineering, including in the field of retinal therapy and photocoagulation. Following the first photocoagulation procedure ever, performed on the roof of a German eye clinic using the sun s natural light, Carl Zeiss soon entered into a close relationship with the most brilliant clinicians of the time to develop the world s first commercial coagulator in 1956. VISULAS Trion Engaged with all of the senses 2

Performance Combining optimal power with safety and stability The VISULAS Trion is designed to provide eye doctors of various disciplines and backgrounds optimum flexibility for a broad spectrum of retinal therapies. A performance class of its own In terms of sheer laser power, the VISULAS Trion sets entirely new standards. Even when alternating between short laser shots and large beam diameters, its power reserves continue to allow for reliable treatment outcomes. In fact, its performance capabilities in the red and yellow wavelengths for example, to treat inhomogeneous media are truly spectacular. Stable and reproducible outcomes With its meticulous laser parameter stability, the VISULAS Trion is the system of choice for reliable and reproducible retinal therapy in clinics that handle large patient volumes. With the VISULAS Trion, you can virtually treat as many patients as you want, as long as you want without performance fluctuations.

Just the right color for every case Depending on the diagnosis, the VISULAS Trion allows you to conveniently select between green, yellow and red wavelengths for the most efficient treatment. In terms of penetration depth, optical density and absorption behavior of the light passing through the ocular media, the VISULAS Trion has the capability to always offer the smoothest treatment alternative. Green the gold standard in retinal photocoagulation Green laser light is primarily absorbed by the retinal pigment melanin, and is therefore well suited for a variety of treatment applications in the retinal pigment epithelium (RPE) region. This primarily applies to pan-retinal photocoagulation (PRP) therapy. Yellow minimally invasive vessel sealing Yellow laser light possesses the highest absorption level for retinal hemoglobin when compared to green and red wavelengths. With its characteristic penetration depth, it offers an efficient and smooth alternative to sealing retinal vessels. It also more effectively penetrates inhomogeneous media such as moderate cataracts. Red deep penetration for choroidal lesions Red laser light is not absorbed well by hemoglobin. It therefore easily penetrates moderate vitreous hemorrhages. Its penetration depth is ideal for selectively treating choroidal vessels, without coagulation of retinal vessels. 4

Carl Zeiss Meditec continues to uphold a long-standing tradition of technological excellence and clinical competence in retinal diagnostics and therapy. This level of dedication has now culminated in the development of the VISULAS Trion, a powerful and compact multicolor solid-state laser designed for smooth retinal applications. Highly precise laser guidance and treatment accuracy. Highly flexible and reliable in daily clinical practice. Highly convenient and intuitive operation. In short: the VISULAS Trion, an exceptional retinal therapy system. Fully engage the retinal pathologies of your patients. Our endless commitment to technological excellence, in-depth understanding of clinical requirements and awareness of our customers needs are the driving forces behind all of our ideas. Performance programmable settings with optimal power and stability Precision highly accurate positioning through extremely sensitive control Productivity flexible utilization for efficient clinical workflows Patient Care individual and gentle treatment for every patient 5

Precision Focused on the essentials With its patented electronic micromanipulator, the VISULAS Trion allows for fast, safe and highly accurate beam guidance. Slightly turned, for example, and the treatment position is set. Various system parameters can be adjusted at the push of a button. The beam is always centered in the illumination field, providing you with a comprehensive view of the treatment region. Navigation at your fingertips A color touch driven control panel allows for convenient and intuitive operation of the VISULAS Trion. With its PowerPress TM button, key laser parameters are quickly and precisely adjusted. Selecting a new wavelength and power parameters for the next patient is practically right at your fingertips. Safe laser positioning Thanks to its patented electronic micromanipulator the VISULAS Trion permits highly accurate guidance of the beam and slit lamp illumination simultaneously. The target beam position is always centered in the treatment beam field. However, it can still be variably controlled in the slit lamp illumination field. The micromanipulator is located directly on the slit lamp joystick, enabling fast, controlled and precise beam guidance for efficient and pinpoint treatment applications. 6

A precise view of everything Equipped with the ACCENTO eyepiece*, the VISULAS Trion lets you continuously monitor treatment critical parameters such as laser power and shot count, while never losing sight of the targeted morphology. Hands-free power adjustments The addition of the ACCENTO footswitch* enables you to make convenient power adjustments without disturbing your view of the retina. After diagnosing the target region, the system intuitively assists you with changing power parameters as needed. ACCENTO eyepiece allows you to keep a sharp eye on the target region and current power setting. 260 mw Conveniently making power adjustments with the ACCENTO footswitch* * Option Green: effectively coagulates photoreceptor and RPE Yellow: carefully coagulates closer to the macula Red: precisely coagulates outer retina through hemorrhages 84 7

Productivity Portable. Flexible. Powerful. In a word: efficient. In many eyecare facilities, lasers are frequently used by a large number of different specialists: for example, in the OR, to treat hospitalized patients or for outpatient retinal consultations. Thanks to its intelligent design, the VISULAS Trion is ideally suited for all of these applications, and for multi-user facilities in general. Quickly switching treatments With its dual illuminated fiber ports, the VISULAS Trion lets you quickly and easily switch from one connected treatment system to another: for example, from a ZEISS slit lamp to an indirect ophthalmoscope, or from an OR endoprobe to an indirect ophthalmoscope with a few simple clicks on the touch screen. Fully integrated into the slit lamp In mobile physician safety filter mode, the ZEISS slit lamp and illuminated beam path brilliantly displays the retina true to color in its natural surroundings. When permanently integrated into the beam path, the physician safety filter can further streamline the treatment procedure. Space-saving design Office space is tight. As the smallest laser of its kind, the VISULAS Trion is a real space saver. Moreover, the system can be combined with the VISULAS YAG III laser as a single slit lamp laser solution to further optimize office space utilization. Performance to go The VISULAS Trion is also the lightest laser of its kind. As a portable system, it is easily moved from one location to another in virtually no time. 8

Patient Care Individual and controlled photocoagulation Optimizing treatment outcomes while also improving the patient experience are core values of the technology developed by Carl Zeiss Meditec. The VISULAS Trion makes no exception, which combines a variety of technological advancements aimed at increasing treatment safety and the quality of patient care. Optimized treatment selectivity Through the combination of its multiwavelength capabilities and its highly accurate beam path, the VISULAS Trion allows you to conduct highly precise and selective laser applications. Tissue layers near the targeted pathology can thus be coagulated with pinpoint precision. Reliable protection of anterior ocular media Thanks to its patented ParFocus TM zoom, the VISULAS Trion trains a homogeneous, sharply defined and reproducible laser spot on the retina, without the risk of heat-related side effects on the patient s cornea. Individual treatment strategies Whether to target localized pathologies with short laser shots, to homogeneously distribute the laser energy over a large area, for controlled applications in single shot mode, or for quick and efficient applications repetition mode, the VISULAS Trion allows you to develop individual and variable treatment strategies. Always placing the patient at the center of your focus. 9

VISULAS Trion laser system Technical data Laser type Wavelength Frequency doubled solid-state laser 532 nm, 561 nm, 659 nm Max. power at cornea Aiming beam Electrical connection Pulse duration Cooling system Laser console dimensions Weight Accessories Laser Slit Lamp LSL Trion 1.5 W (GREEN, 532 nm) 0.8 W (YELLOW, 561 nm) 1.0 W (RED, 659 nm) Diode, 630 670 nm, max. 1 mw at the cornea 100 V 240 V AC, 50/60 Hz Continuously adjustable, 0.01 s 3 s Thermo-electric, air cooled H 785 x W 330 x D 670 mm (H 30.9 x W 13.0 x D 26.4 inches) 48 kg (105.6 lbs.) Endoprobes, LIO Trion laser indirect ophthalmoscope, instrument table, laser safety eye glasses, contact lenses, ACCENTO footswitch Laser beam delivery Interlaced with slit illumination system Laser spot size Illumination Slit adjustment Physician safety filter Micromanipulator Weight Accessories Continuously adjustable, 50 1000 μm (without contact lens), parfocal, larger spot sizes depending on contact lens utilized 12 V, 30 W, brightness continuously adjustable Slit length in variable steps of 1/3/5/9/14 mm Slit width continuously adjustable: 0 14 mm Slit image rotation: 0, ±45, 90 True-to-color, automatically swings into position during treatment pulses or permanently remains in the treatment beam path Servo-electric 11 kg (24.2 Ibs.) Tonometer, assistant s scope, video documentation equipment etc. from the range of accessories for the SL 120 and SL 130 slit lamps, ACCENTO eyepiece Publication No: 000000-1504-915 The contents of the brochure may differ from the current status of approval of the product in your country. Please contact our regional representative for more information. Subject to change in design and scope of delivery and as a result of ongoing technical development. Printed on elemental chlorine-free bleached paper. P UBLICIS IV/08. 2008 by Carl Zeiss Meditec AG. All copyrights reserved. Carl Zeiss Meditec AG Goeschwitzer Str. 51 52 07745 Jena GERMANY Phone: +49 36 41 22 03 33 Fax: +49 36 41 22 02 82 info@meditec.zeiss.com www.meditec.zeiss.com Carl Zeiss Meditec Inc. 5160 Hacienda Drive Dublin, CA 94568 USA Phone: +1 925 557 41 00 Fax: +1 925 557 41 01 info@meditec.zeiss.com www.meditec.zeiss.com