INSTRUCTION MANUAL DIGITAL MULTIMETER

Similar documents
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Digital Multimeter with Backlight

AMM-1022 Digital Multimeter USER`S MANUAL

OPERATOR S INSTRUCTION MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Model DIGITAL MULTIMETER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DMM8900 SERIES USERS MANUAL

M-1000D DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DIGIT & POINTER MULTIMETER

User Manual Digital Multimeter

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model : OPERATING MANUAL Table of Contents (1)

DVM1190 DIGITAL MULTIMETER

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

AUTO RANGING DIGITAL MULTIMETER

3B SCIENTIFIC PHYSICS

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

VC835 DIGTAL MULTIMETER Operation Manual

ProfiScale MULTI Multimeter

Pocket Size Digital Multimeter Models: and

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

AC/DC CLAMP METER USER S MANUAL

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

MS2030 CAT III 600 V A V AUTO RS232

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Digital Clamp Meter Model: &

DIGITAL MULTIMETER OPERATOR S MANUAL

MS8223A. CAT.IIi 600 V

Table of Contents Title Page

Sales: Technical: Fax:

Digital Clamp Meter. User Manual

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

KMD-S04 Multímetro de bolsillo

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Digital Multimeter AX-572. Instruction manual

Analog Technologies VC99. Multimeter FEATURES

ET-3888 True RMS Clamp Meter. User Manual

USER'S MANUAL DMR-6700

DIGITAL MULTIMETER AUTORANGING

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Model UT39A/B/C: OPERATING MANUAL

CONTENTS MS2033A. 1.Introduction Safety Information...01

User Manual Digital Multimeter. model no.: MSR-U1000

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

770E DIGITAL MULTIMETER OPERATOR S MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

Multifunction Digital

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Handheld Digital Multimeter PRO-50A

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

OPERATOR S INSTRUCTION MANUAL

Digital Multimeter, Pen Type

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL MULTIMETER AX-588B

Pen-type DIGITAL MULTITESTER

USER'S MANUAL DMR-4300

1.General instructions Specifications Description...7

Model UT20B: OPERATING MANUAL Table of Contents (1)

Table of Contents GDM-356. Page

Model UT10A: OPERATING MANUAL Table of Contents (1)

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Digital Clamp Meter (TRMS) Model : 2727

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

User Manual. All rights reserved. Specifications are subject to change without notice.

312, 316, 318. Clamp Meter. Users Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

The Meter Structure The Figure 2-1 shows the Meter structure.

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

OPERATING INSTRUCTION

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Transcription:

INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V

Thanks for buying our products, please go through the instruction manual before starting to use the meter, and carefully follow these safety rules. GENERAL This series are a series of compact pocket-sized 3 1 / 2 digit multimeter for measuring DC and AC voltage, DC and AC current, resistance, temperature, transistor measurement, diode and audible continuity test function. Full range overload protection and low battery voltage indication are provided. They are ideal instruments for use in fields, such as laboratory, workshop, hobby and home applications. DCV ACV DCA Ω h FE Temp SAFETY WARNINGS This instrument has been designed, manufactured and tested according to the following standards. EN 61010-1 : 1 over voltage CAT Ⅱ 600V EN 61010-2-031 : 1995 EN 61000-4-2 (3) : 1 (2) - 1 -

Safety symbols: exists high voltage GND dual insulation must refer to manual low battery This instruction manual contains warnings and safety rules which must be observed by the user to ensure safe operation of the instrument and retain it in safe condition. Therefore, read through these operating instructions before using the instrument. DANGER is reserved for the conditions and actions that are likely to cause serious or fatal injury. WARNING is reserved for the conditions and actions that can cause serious or fatal injury. CAUTION is reserved for the conditions and actions that can cause injury or instrument damage. DANGER Never make measurement on the circuit in which electrical potential to ground over 500V AC/DC exists. Do not attempt to make measurement in the presence of flammable gasses. Otherwise, the use of the instrument may cause sparking, which can lead to an explosion. Be sure to keep your fingers behind the finger barrier part of test lead. Never attempt to use the instrument if its surface or your hand is wet. Do not open the instrument case when making measurement. - 2 -

WARNING Never attempt to make any measurement if any abnormal conditions are noted, such as broken case, cracked test leads and exposed metal parts. Do not turn the function selector switch with test leads connected to the instrument. Do not install substitute parts or make any modification to the instrument. Do not try to replace the batteries if the surface of the instrument is wet. Make sure to disconnect test leads from the device under test when opening the case for battery replacement. CAUTION Always make sure to check function switch is setting to the appropriate range before starting measurement. Do not expose the instrument to the direct sun, high temperature and humidity or dewfall. When the instrument will note be in use for a long period, place it in storage after removing the batteries. Use a cloth dipped in water or neutral detergent for cleaning the instrument. Do not use abrasives or solvents. - 3 -

FRONT PANEL DESCRIPTION 1 600 OFF 600 2 20 2m 2 20m m m 6 2M k 20k 2k O C 10A NPN PNP hfe E B C E 3 5 4 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V 1. DISPLAY 3 1 / 2 digit, 7 segment, 12.5mm high LCD. 2. FUNCTION AND RANGE SWITCH This switch is used to select the function and desired range as well as to turn on the instrument. To extend the life of battery, the switch should be in the OFF position when the instrument is not in use. 3. Transistor measurement socket - 4 -

4. VΩmA Input terminal Plug in connector for red (positive) test lead for all voltage and resistance and current (except 10A) measurements. 5. 10A Input Terminal Plug in connector for red (positive) test lead for 10A measurements. 6. Common Input terminal Plug in connector for black (negative) lead. GENERAL CHARACTERISTICS Display 3 1 / 2 digit LCD with Max. display 1999. Polarity Auto polarization Measurement speed: Updates 2~3 times /second. Battery 9V, NEDA 1604 or 6F22 or 006P Storage -15 ~ 50 Size 128(D) 70(W) 34(H)mm. Weight 137g Low volt left side of LCD will show symbol Working temperature : 0 ~ 40, relative humidity : < 75% Over range maximum display "1" or "-1" TECHNICAL SPECIFICATIONS Accuracies are guaranteed for 1 year, 23 ± 5, less than 75% RH. DC VOLTAGE Range Resolution Accuracy mv 100µV ±(0.5% rdg + 2 dgt) 2V 1mV ±(0.8% rdg + 3 dgt) 20V 10mV ±(0.8% rdg + 3 dgt) V 100mV ±(0.8% rdg + 3 dgt) 600V 1V ±(0.8% rdg + 5 dgt) Overload protection : 220V rms AC for mv range and 600V DC or 600V rms AC for other ranges. - 5 -

DC CURRENT Range Resolution Accuracy µa 0.1µA ±(1% rdg + 2 dgt) 2mA 1µA ±(1% rdg + 2 dgt) 20mA 10µA ±(1% rdg + 2 dgt) ma 100µA ±(1.2% rdg + 2 dgt) 10A 10mA ±(2% rdg + 2 dgt) Overload protection : ma / 250V fuse Measuring voltage drop : mv AC VOLTAGE Range Resolution Accuracy V 100mV ±(2% rdg + 2 dgt) 600V 1V ±(2% rdg + 2 dgt) Overload protection : 600V DC or 600V rms AC Response : Average responding, calibrated in rms of a sine wave. Frequency range : 40 ~ 400Hz RESISTANCE Range Resolution Accuracy Ω 0.1Ω ±(0.8% rdg + 5 dgt) 2kΩ 1Ω ±(0.8% rdg + 2 dgt) 20kΩ 10Ω ±(0.8% rdg + 2 dgt) kω 100Ω ±(0.8% rdg + 2 dgt) 2MΩ 1kΩ ±(1.2% rdg + 3 dgt) Maximum open circuit voltage : 2.8V Overload protection : 10 seconds max. 220V rms TEMPERATURE (K TYPE) Range Resolution Accuracy -40 ~ 1000 1 ±(1% rdg +3 dgt)(up to 400 ) ±(2% rdg +3 dgt)(over 400 ) - 6 -

Overload Protection : 220V rms AC Diode Test RANGE DESCRIPTION Display voltage drop approximation CONTINUITY RANGE DESCRIPTION Built-in buzzer sounds if resistance is less than 70Ω Overload protection : 10 seconds max. 220V rms Transistor h FE measurement Range Displaying range h FE (NPN or PNP) 0~1000 Test condition Basic current is approx. 10µA,Vce is approx. 3V OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT 1. Connect red test lead to VΩmA, black test lead to COM jack. 2. Set the rotary switch to DC V position. If the voltage to be measured is not known beforehand, set switch to the highest range and reduce it until satisfactory reading is obtained. 3. Connect test leads to device or circuit being measured. 4. Turn on power of the device or circuit being measured, voltage value will appear on digital display along with the voltage polarity. AC VOLTAGE MEASUREMENT 1. Red test lead to VΩmA, black lead to COM. 2. Set the range switch to AC V position. - 7 -

3. Connect test leads to device or circuit. 4. Read voltage value on digital display. DC CURRENT MEASUREMENT 1. Red test lead to VΩmA, black lead to COM (For measurements between ma and 10A connect red lead to 10A jack with fully depressed) 2. Set the range switch to DC A position. 3. Open the circuit to be measured and connect test leads INSERIES with the load in which current is to be measured. 4. Read current value on digital display. RESISTANCE MEASUREMENT 1. Red test lead to VΩmA, Black lead to COM. 2. Set the range switch to Ω position. 3. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before measurement. 4. Connect test leads to circuit being measured. 5. Read resistance value on digital display. TEMPERATURE MEASUREMENT 1. Set the range switch to position. 2. Insert the black plug of thermocouple into COM terminals and the red plug to VΩmA terminals, put working end into measurement place. 3. The display will read the temperature value. TEST SIGNAL USE 1. Set the range switch to position. 2. Test signal (50Hz) appears between VΩmA and COM jacks. The output voltage is approx 5V p-p with 50k ohm impedance. - 8 -

DIODE MEASUREMENT 1. Red test lead to VΩmA, black lead to COM. 2. Set the range switch to position. 3. Connect the red test lead to the anode of the diode to be measured and black test lead to cathode. 4. The forward voltage drop in mv will be displayed. If the diode is reversed, figure 1 will be shown. AUDIBLE CONTINUITY TEST 1. Red test lead to VΩmA, black lead to COM. 2. Set the range switch to position. 3. Connect test leads to two points of circuit to be tested, if the resistance is lower than 70Ω, buzzer will sound. TRANSISTOR h FE MEASUREMENT 1. Set the rotary switch to NPN or PNP range; 2. NPN or PNP type transistor will be inserted into the E, B, C socket. 3. Read resistance value on digital display. BATTERY AND FUSE REPLACEMENT Fuse rarely need replacement and blow almost always as a result of operator error. If appears on display, it indicates that the battery should be replaced. To replace battery & Fuse (ma / 250V) remove the 2 screws in the bottom of the case. Simply remove the old and replace with a new one. Be careful to observe polarity. CAUTION Before attempting to open the case of the instrument, be sure to disconnect test leads from any energized circuits to avoid shock hazard. - 9 -