CERTIFICATE OF COMPLIANCE

Similar documents
Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Intrinsic Safety Control Drawing

CERTIFICATE OF COMPLIANCE

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

JM Enclosure Dimensions (in mm)

IP26 Series Current to Pneumatic Converter

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

Product manual wire programmable RTD transmitter

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Loop Powered Indicator

EN Series Installation Manual

Power supply. Calibration. Surface finishing. Seal. Process connection

Fieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

COMMUNICATION NETWORKS

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

Certificate of Compliance

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

User s Manual YOKOGAWA. Model PH202G (S) ph Transmitter. IM 12B6C3-E-E 12th Edition

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

Product Manual wire HART transmitter

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

LIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

PROline promag 53 Division 1

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

Product Manual wire HART transmitter

Certificate of Compliance

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

Certificate of Conformity

YVP110 Advanced Valve Positioner

INSTRUCTION & SAFETY MANUAL

ControlNet Ex Tap Terminator Installation Instructions

PROFIBUS PA / FOUNDATION Fieldbus Transmitter. No. 6350V103-UK From ser. no

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Industrial Pressure Transducers

megablock series passive hubs for fieldbus networks

DPharp Fieldbus Communication Type (EJX A, EJA E)

Model DY Vortex Flowmeter Model DYA Vortex Flow Converter Fieldbus Communication Type

A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters

ORIGINAL SIZE SYSTEM CONTROL DWG. FILE. ROSEMOUNT 2410 OrCADl. o o

INTRINSICALLY SAFE DUPLEXER

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

General Specifications

Certificate of Conformity

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

DPharp Fieldbus Communication Type (EJX A, EJA E)

LIQ_MAN_ABR_5081T-HT/Rev. L January 2015

Universal Intelligent 2-wire DIN Rail Transmitters

Safety Instructions Micropilot NMR81, NMR84

DPharp Differential Pressure and Pressure Transmitters

Head mounted Temperature Transmitter TF02/TF02-Ex

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

YTA610 and YTA710 Temperature Transmitter (Hardware)

FLEX Ex Power Supplies

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Level Lance Model 5100

ATEX Installation Drawings and Instructions

Product manual 5350 PROFIBUS PA / FOUNDATION Fieldbus transmitter

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

Instruction Manual LIQ_MAN_5081A-FF/rev.M January A. FouNdAtIoN Fieldbus two-wire Chlorine, dissolved oxygen, and ozone transmitter

FLEX Ex Thermocouple/RTD Input Module

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

1-830 SERIES DISPLACEMENT TRANSMITTER

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

YTA Series Temperature Transmitters (Hardware) [Style: S3]

General Specifications

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

10 Mb/s Single Twisted Pair Ethernet Powering in an Intrinsically Safe System Steffen Graber Pepperl+Fuchs

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Title: INTRINSIC SAFETY MADE EASY

Universal Intelligent 2-wire In-head Transmitters

Fisher 646 Electro Pneumatic Transducer

IECEx Certificate of Conformity Annexe

Certificate of Compliance

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Transcription:

FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: SITRANS TH400 7NG-21*-*NN** Transmitter NI / I / 2 / ABCD / T* Ta = * A5E01002219A NIFW; FNICO; Type 2 *See table. Nonincendive Field Wiring Parameters VMax = 2 V, Ci = 2.0 nf, Li = 1 µh. T1..T4: Ta +85 C T5: Ta +70 C T: Ta +0 C Special Condition for Use: 1. The TH400 7NG-21*-*NN** Transmitter shall be installed in compliance with the enclosure, mounting, and spacing, and segregation requirement of the ultimate application. SITRANS TH400 7NG-21*-*AN** Transmitter. IS / I / 1 / ABCD / T*_4 Ta = * A5E01002219A Entity, Fisco; Type 2 I / O / AEx ia / IIC / T*_4 Ta = * A5E01002219A Entity, Fisco; Type 2 NI / I / 2 / ABCD / T*_4 Ta = * A5E01002219A NIFW; FNICO; Type 2 *See table. Special Condition for Use: 1. The TH400 7NG-21*-*AN** Transmitter shall be installed in compliance with the enclosure, mounting, and spacing, and segregation requirement of the ultimate application. FM Approvals HLC /07 027985 Page 1 of

Barrier Linear Trapezoid Suitable for Suitable for Type: Barrier Barrier FISCO Systems FISCO Systems T1..T4: Ta +85 C Ta +75 C Ta +85 C Ta +85 C T5: Ta +70 C Ta +5 C Ta +0 C Ta +0 C T: Ta +0 C Ta +45 C Ta +45 C Ta +45 C VMax or Ui 0 V 0 V 17,5 V 15 V IMax or Ii 120 ma 00 ma 250 ma 900 ma Pi 0,84 W 1, W 2,0 W 5.2 W Ci 2,0 nf 2,0 nf 2,0 nf 2,0 nf Li 1 µh 1 µh 1 µh 1 µh Equipment Ratings: The TH400 7NG-21*-*NN** is suitable for Class I, Division 2, Groups A, B, C, and D hazardous (classified) locations. The TH400 7NG-21*-*AN** is Intrinsically safe for Class I, Division 1, Groups A, B, C, and D, intrinsically safe for Class I, Zone 0, Group IIC, intrinsically safe for Class I, Zone 1, Group IIC, and suitable for Class I, Division 2, Groups A, B, C, and D hazardous (classified) locations. FM Approved for: Siemens AG Karlsruhe, Germany FM Approvals HLC /07 027985 Page 2 of

This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class 00 1998 Class 10 2010 Class 1004 Class 810 1989 Including Supplement #1 1995 ANSI/ISA 0079-0 2009 ANSI/ISA 0079-1009 Original Project ID: 027985 Approval Granted: January 29, 2007 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date 04205 March 2, 2011 FM Approvals LLC Patrick Byrne Technical Team Manager April 5, 2011 Date FM Approvals HLC /07 027985 Page of

FM-CSA Installation Drawing. Model SITRANS TH 400 7NG21*-0AN00 Hazardous (Classified) Location Unclassified Location Class I,Division1, Groups, A,B,C,D OR Class I, Zone 0, IIC Associated Apparatus Barrier or FISCO Supply wit entity Parameters: Approved Termination Terminal, 4, 5, Vt or Uo : 5,71 V It or Io : 8,4 ma Pt or Po : 12 mw Ca or Co : 40 uf La or Lo : 200 mh 4 5 4 5 4 5 U < 250V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable This device must not be connected to any associated apparatus which uses or generates more than 250 VRMS Barrier type: Terminal 1,2 Class I, Zone 0, Ex ia IIC, Entity / FISCO IS, Class I, Division 1, Group A, B, C, D Entity / FISCO Linear barrier Trapezoid barrier Suitable for FISCO systems Suitable for FISCO systems T1..T4: Ta +85 C Ta +75 C Ta +85 C Ta +85 C T5: Ta +70 C Ta +5 C Ta +0 C Ta +0 C T: Ta +0 C Ta +45 C Ta +45 C Ta +45 C Vmax or Ui 0 V 0 V 17.5 V 15 V Imax or Ii 120 ma 00 ma 250 ma 900 ma Pi 0.84 W 1. W 2.0 W 5.2W Ci 2.0 nf 2.0 nf 2.0 nf 2.0 nf Li 1 μh 1 μh 1 μh 1 μh See Installation notes. SIEMENS AG A5E01002219A REV. 000-11-15 1/

Model SITRANS TH 400 7NG21*-0AN00 Hazardous (Classified) Location Unclassified Location Class I,Division2, Groups, A,B,C,D OR Class I, Zone 1, IIC Approved Termination Terminal, 4, 5, Vt or Uo : 5,71 V It or Io : 8,4 ma Pt or Po : 12 mw Ca or Co : 40 uf La or Lo : 200 mh 4 5 4 5 4 5 Associated Apparatus Barrier entity Parameters: U < 250V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable or FISCO Supply This device must not be connected to any associated apparatus which uses or generates more than 250 VRMS Barrier type: Entity Parameters Terminal 1, 2 Class I, Zone 1, Ex ib IIC Entity / FISCO Rectangular barrier FISCO Segment coupler T1..T4: Ta +85 C Ta +85 C T5: Ta +75 C Ta +75 C T: Ta +0 C Ta +0 C Vmax / Ui 0 V 17.5 V Imax or Ii 250 ma any Pi 5.2 W any Ci 2.0 nf 2.0 nf Li 1 μh 1 μh Nonincendive Field Wiring parameters Terminal 1, 2 NI, Class I, Division 2, Group A, B, C, D NIFW/ FNICO T1..T4: Ta +85 C Ta +85 C T5: Ta +75 C Ta +75 C T: Ta +0 C Ta +0 C Vmax / Ui 0 V 17.5 V Pi 5.2 W any Ci 2.0 nf 2.0 nf Li 1 μh 1 μh For a current-controlled circuit the parameter Imax is not required and need not be aligned with the parameter Isc or It of the barrier or associated nonincendive field wiring apparatus. See Installation notes. SIEMENS AG A5E01002219A REV. 000-11-15 2/

Model SITRANS TH 400 7NG21*-0NN00 Hazardous (Classified) Location Unclassified Location Class I,Division2, Groups, A,B,C,D OR Class I, Zone 2, IIC 2V Class 2 Power Supply Approved Termination 4 5 This device must not be connected to any associated apparatus which uses or generates more than 250 VRMS Terminal, 4, 5, Vt or Uo : 5.71 V It or Io : 8.4 ma Pt or Po : 12 mw Ca or Co : 40 μf La or Lo : 200 mh Terminal 1.2 Ci: 2.0 nf Li: 1 μh T1..T4 T5 T -40 C Ta +85 C -40 C Ta +75 C -40 C Ta +0 C See installation notes: SIEMENS AG A5E01002219A REV. 000-11-15 /

Installation notes: FM / CSA: For installation in the US the equipment shall be installed according to the National Electrical Code (ANSI-NFPA 70). For installation in Canada the transmitter shall be installed in a suitable enclosure to meet installation codes stipulated in the Canadian Electrical Code (CEC). The entity concept: Equipment that is FM / CSA-approved for intrinsic safety may be connected to barriers based on the ENTITY CONCEPT. This concept permits interconnection of approved transmitters, meters and other devices in combinations which have not been specifically examined by FM / CSA, provided that the agency's criteria are met. The combination is intrinsically safe, if the entity concept is acceptable to the authority having jurisdiction over the installation. The entity concept criteria are as follows: The intrinsically safe devices, other than barriers, must not be a source of power. The maximum voltage Ui (V MAX ) and current Ii (I MAX ), and maximum power Pi (Pmax), which the device can receive and remain intrinsically safe, must be equal to or greater than the voltage (Uo or V OC or V t ) and current (Io or I SC or I t ) and the power Po which can be delivered by the barrier. The sum of the maximum unprotected capacitance (C i ) for each intrinsically device and the interconnecting wiring must be less than the capacitance (C a ) which can be safely connected to the barrier. The sum of the maximum unprotected inductance (L i ) for each intrinsically device and the interconnecting wiring must be less than the inductance (L a ) which can be safely connected to the barrier. The entity parameters Uo,V OC or V t and Io,I SC or I t, and C a and L a for barriers are provided by the barrier manufacturer. FISCO/FNICO rules: The FISCO Concept allows the interconnection of intrinsically safe apparatus to associated apparatus not specifically examined in such combination. The criterion for such interconnection is that the voltage (Vmax), the current (Imax) and the power (Pi) which intrinsically safe apparatus can receive and remain intrinsically safe, considering faults, must be equal or greater than the voltage (Uo, Voc, Vt), the current (Io, Isc, It,) and the power (Po) which can be provided by the associated apparatus (supply unit). In addition, the maximum unprotected residual capacitance (Ci) and inductance (Li) of each apparatus (other than the terminators) connected to the Fieldbus must be less than or equal to: FISCO: 5 nf and 10 μh. FNICO: 5 nf and 20 μh The Nonincendive Field Wiring concept allows the interconnection of FM-approved nonincendive devices with FNICO parameters not specifically examined in combination as a system when: Uo or Voc or Vt <= Vmax, Po <= Pi SIEMENS AG A5E01002219A REV. 000-11-15 4/

In each I.S. Fieldbus segment only one active source, normally the associated apparatus, is allowed to provide the necessary power for the Fieldbus system. The allowed voltage (Uo, Voc, Vt) of the associated apparatus used to supply the bus must be limited to the range of 14V d.c. to 24V d.c. All other equipment connected to the bus cable has to be passive, meaning that the apparatus is not allowed to provide energy to the system, except to a leakage current of 50 μa for each connected device. Separately powered equipment needs a galvanic isolation to insure that the intrinsically safe Fieldbus circuit remains passive. The cable used to interconnect the devices needs to comply with the following parameters: Loop resistance R': 15...150 Ω/Km Inductance per unit length L': 0.4 1mH/km Capacitance per unit length C': 80...200 nf/km C' = C' line/line + 0.5 C' line/screen, if both lines are floating or C'= C' line/line + C' line/screen, if the screen is connected to one line Length of spur Cable: max. 0 m Length of trunk cable: max. 1 Km Length of splice: max. 1 m Terminators At each end of the trunk cable an approved line terminator with the following parameters is suitable: R = 90...100 Ω C = 0...2.2 μf. System evaluation The number of passive devices like transmitters, actuators, connected to a single bus segment is not limited due to I.S. or N.I. reasons. Furthermore, if the above rules are respected, the inductance and capacitance of the cable need not to be considered and will not impair the intrinsic safety or non incendive safety of the installation as applicable. The sensor circuit is not infallibly galvanically isolated from the Fieldbus input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500 Vac during 1 minute. Nonincendive Field Wiring Concept: The Nonincendive Field Wiring concept allows for the interconnection of nonincendive field wiring apparatus using any of the wiring methods permitted for unclassified locations. Vmax >= Voc or Vt, Ca >= Ci +Ccable, La >= Li + Lcable" SIEMENS AG A5E01002219A REV. 000-11-15 5/

Installation Notes For FISCO and Entity Concepts: 1. The Intrinsic Safety Entity concept allows the interconnection of FM / CSA-approved intrinsically safe devices (Div. 1 or Zone 0 or Zone1), with entity parameters not specifically examined in combination as a system when: Uo or Voc or Vt Vmax, Io or Isc or It Imax, Po Pi. Ca or Co ΣCi + ΣCcable, La or Lo ΣLi + ΣLcable, Po Pi. 2. The Intrinsic Safety FISCO concept allows the interconnection of FM / CSA-approved intrinsically safe devices with FISCO parameters not specifically examined in combination as a system when: Uo or Voc or Vt Vmax, Io or Isc or It Imax, Po Pi.. Control equipment connected to the Associated Apparatus must not use or generate more than 250 Vrms or Vdc. 4. Intrinsically Safe Installation should be in accordance with ANSI/ISA RP12..01 (except chapter 5 for FISCO Installations) Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code (ANSI/NFPA 70) Sections 504 and 505. 5. The configuration of associated Apparatus must be FM Approvals or CSA Approved under the associated concept.. Associated Apparatus manufacturer s installation drawing must be followed when installing this equipment. 7. The equipment is approved for Class I, Zone 0, applications. If connecting AEx[ib] associated Apparatus or AEx ib I.S. Apparatus to the equipment the I.S. circuit is only suitable for Class I, Zone 1, or Class I, Zone 2, and is not suitable for Class I, Zone 0 or Class I, Division 1, Hazardous (Classified) Locations". 8. No revision to drawing without prior FM / CSA Approval. 9. Simple Apparatus is defined as a device that neither generates nor stores more than 1.5 V, 0.1 A or 25 mw. 10. The termination must be NRTL-approved, and the resistor must be infallible. 11. Warning: For applications in Div. 2 or Zone 2 (Classified Locations) Explosion hazard: Except for nonincendive field circuits, do not disconnect the apparatus unless the area is known to be non hazardous. 12. Warning: Substitution of Components May Impair Safety. SIEMENS AG A5E01002219A REV. 000-11-15 /