HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Similar documents
P.O. BOX 1521 POLSON, MT SSR V-12C

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

SSR VL-12P-xC-NCS

SSR-150xxx-40VL-12P-xC-xxxCS

Preliminary Data Sheet!

Signal Isolation Module. Instruction Manual SIM

PCO-7114 Laser Diode Driver Module Operation Manual

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Precision Frequency To Voltage Converter Card

MaxLite LED Self-Driven LiteBars

Gypsy Statement of Limited Warranty. Part 1 General Terms

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

380 SERIES REPAIR PARTS INDEX. NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

TRANSDUCER IN-LINE AMPLIFIER

TRANSDUCER IN-LINE AMPLIFIER

automatic embosser & die cutter USER MANUAL

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Master Reference Unit

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

Glass Electrode Meter

Model 935A Current Source Operation Manual

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Pen Multimeter. Model

80i-600A AC Current Probe

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

CDT. Service and Installation Manual. Manual Revision Oct 2014

CRD 410 MANUAL FITTING INSERTER

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Multiplier and Divider Card

MODEL 3810/2 Line Impedance Stabilization Network

200Amp AC Clamp Meter + NCV Model MA250

Warranty Terms & Conditions

K-FACTOR SCALER B & B

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

Questions? Call Toll-Free

PA Watt Compact Two Zone Amplifier to Drive up to 60 Paging Speakers. 60 Watt / 2 Zone Power Amplifier. Features. Applications.

ARBE-III Instruction Manual

Programmable K-Factor Scaler B and Programming Software Kit B

Instruction Sheet SNE SERIES. Cable Chase

PARTS CATALOG FRONT WHEEL DRIVE FOR JOHN DEERE 6100 & WHEEL SPRAYERS

User s Guide Instructions for Installation and Operation

420 SERIES. TWO Stage Vertical and

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

110A SERIES REGENERATIVE TURBINE PUMPS REPAIR PARTS INDEX

Shiba Drive USER MANUAL

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

742A Series Resistance Standards

RIOT DISTORTION USER GUIDE

E3X-DRT21/SRT21/CIF11

WireMaster Coax BNC PN: Rev C 2/13

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Low Voltage Brushed Motor System

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

INSTRUCTION MANUAL FOR CELL SIMULATOR MODEL 2410

SNAP-FAN INSTALLATION

User Guide. Digital AC/DC Clamp Meter Model 38394

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

SX204. Headphone Amplifier. Symetrix. Owner s Manual

Pen Multimeter. Model

Amplified High Speed Photodetectors

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

User s Guide. Digital AC/DC Clamp Meter Model 38394

Pre-Filter. Brushless/ Sparkless Blower. HEPA Filter. Fluorescent Light

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

Tilting & Swiveling Flat Panel Wall Mount Installation Guide Model: AXS2040

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

Installation Instructions

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

BC145 SIGNAL ISOLATOR BOARD

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

INSTRUCTION MANUAL. C1701 Relay Kit. December Copyright 2007 Campbell Scientific (Canada)Corp.

Radio Remote(s) (Installation Manual)

Instruction Sheet D-CPU. Secure CPU Holder

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Inline Antenna Signal Amplifier

Digital Lighting Systems, Inc.

Grid Radar Installation Manual

7I25 H-BRIDGE MANUAL

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

Two Element Phased Vertical Array System

Broadband Step-Up Transformer. User Manual

Table of Contents. Safety Notices

Instruction Manual Inductive Gauging Sensor

Series 3000 Model R-107A

Interface Box. Instructions H EN

AMP-13 OPERATOR S MANUAL

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Transcription:

HELLRORING TEHNOLOGIES, IN. P.O. OX 1521 POLSON, MT 59860 406 883-3801 HTTP://WWW.HELLRORING.OM SLES12@HELLRORING.OM SSR-15240-60V-xx The SSR-15240-60V-xx are designed for positive D load switching (solid state relay) applications for voltages up to 60 Vdc (Power sources up to 36Vdc) and a control voltage input of (xx) volts at approximately 10 m. -12 model uses 12V control voltage and a -24 model uses 24 Volts at the control voltage. This unit does utilize opto-isolation. Many applications will benefit by the reliable, high current, dc switching capability. The SSR-15240-60V-xx unit can switch either the high side or low side and can be configured for back to back mosfet output at half the current rating and 4 times the on resistance. Should you have a specific application or question not covered here, feel free to send an e-mail technical support request. Include as much detail as practical regarding your application. Send to: sales12@hellroaring.com. Depending on your power source capability and wire size utilized, appropriate circuit protection should be installed. The following table includes recommendations for wire protection values. In all cases, we recommend using circuit protection no greater than 150 amps. Wire Size WG ircuit protection 4 150 6 100 8 60 10 40 12 25 The circuit protection listed is for continuous current. Industrial Switching pplications: Wire per one of the Load Switching pplications diagram illustrated below. Diode suppression for inductive loads is recommended for most applications. For the H-bridge configuration using 4 units, additional diode suppression may not be necessary but is recommended anyway. For installation, follow these steps: 1) For highly inductive loads, Verify the load has diode suppression installed as illustrated. 2) onnect the power source Positive (+) to terminal and. 3) onnect the load (+) to terminal. The other side of the load should be connected to the power source common. The unit is now ready for switching. pply control voltage (12 Vdc for the -12 model and 24 Vdc for the -24 model (requires 20 m) to the control signal input as desired and within the limits specified. Do not disconnect the load while the SSR is switched ON. Note on Diode Suppression The Hellroaring SSR-15240-60V-xx series have built-in suppression for slight inductive loads with dissipation up to 1 Joule. For higher inductive energy, you will need to use external means to protect the SSR. Typically, a TVS diode across the SSR and a Free Wheeling diode or a bi-directional TVS across the load are recommended for best protection. Hellroaring Technologies, inc. http://www.hellroaring.com P.O. ox 1521, Polson, Montana 59860

Hellroaring SSR-15240-60V-xx Instructions D Load Switching Hellroaring SSR-15240-60V-24 simplified schematic ontrol Input (+) ontrol signal input 24 Vdc D source, < 36Vdc (+) (-) D Load dditional TVS or Diode suppression for inductive loads TVS-36V-5K Transient Suppressor Minimum Recommended ontrol Input (-) Figure 1 Some Possible pplications include: D Heater current pulsing. Vehicle D power buss cutoff control. One polarity D motor on/off control. asic D load Switching applications. Rev. Page 2

Hellroaring SSR-15240-60V-xx Instructions ircuit reaker H ridge onfiguration (+) (-) 1 2 D source M 4 3 Relays 1 and 3 ON for motor direction normal. Relays 2 and 4 ON for motor in opposite direction. Never turn ON Relays 1 and 4 or 2 and 3 at the same time. Figure 2 H-ridge Motor ontrol. Some Possible pplications include: High current motor forward and reverse control. Rev. Page 3

Hellroaring SSR-15240-60V-xx Instructions attery ircuit reaker 12V harging with 24 V output 1 4 12 V Loads Main 12V attery attery 3 2 SSR s 1 and 2 ON for 24 volt output. SSR s 3 and 4 ON for 12 V charging of both batteries. Never turn ON Relays 1 and 3 or 1 and 4, or 2 and 4 at the same time. ontrol signal input from main 12 Vdc battery. See recommended control input diagram. 24 V Loads Figure 3 Vehicle 12V system with 24 V accessories. ontrol Input (+) (from Main 12V system) 1 amp fuse 12 to 24 V switching control input 4 each Hellroaring SSR-85250-55V-12 units 1 2 3 4 Use a three position switch. enter = all SSR s off and batteries are isolated. 24V position provides 24 V output. 12V position provides parallel for 12 volt charging. 24 V 12 V Micro Switch ontrol Input (-) Figure 4 ontrol Input diagram for 12V-24V system of fig 3. Rev. Page 4

Hellroaring SSR-15240-60V-xx Instructions Reference figure 3 & 4 on the previous page. This configuration can be used where 24 volt accessories are needed with 12 V vehicles. The 4 SSR s switch a second battery between series (for 24 volt outputs) and parallel (for second battery charging.) SSR, for 24V I function lternator 24V Fuse or circuit breaker 8 or 10 WG wire 8 or 10 WG (5mm) wire 5-7 Meters attery Main SSR-15240-60V-24 TVS TVS ontrol + - ontrol attery uxiliary Use 24V-IM for Sensing and ontrol Figure 5 For other applications or possible setups, check our web site http://hellroaring.com for additional suggested configurations or other tips. If you have other questions you can send e-mail to sales12@hellroaring.com. Please include your serial number. Rev. Page 5

Hellroaring SSR-15240-60V-xx Instructions Definitions: ontrol Input: These terminals, when connected to a voltage of 18 to 30 volts (24V nominal) will cause the terminals,, and to electrically ombine (switch ON). These terminals, when open circuited, will cause the terminals,, and to switch OFF. Input resistance is about 2k ohms resulting in only 0.01 amps with a 24 Vdc input. The input voltage (input current) has a direct effect on the turn on time. This is about 5 to 8 ms with a 24 Vdc input. Terminals,, & : Terminals and are typically jumpered together to obtain the maximum current capability. When Jumpered, terminals and must be more positive than terminal and are normally connected to the power source positive for high side switching (or the load negative for low side switching). Terminal would normally be connected to the load for high side switching (or to the power source negative for low side switching). Terminals and are the cathode end of a diode and terminal is the node. Dimensions: Weight: 4.8 long, by 3.0 wide, by 2.0 to the top of the terminal studs. 12 Oz., typical with 4 WG jumper. Rev. Page 6

Hellroaring SSR-15240-60V-xx Instructions Specifications: SSR-15240-60V-24: Unless specified otherwise ambient temp=25; max current from terminals to parallel &. Max voltage 60 volts continuous 36 Vdc Recommended Max power source with 36V TVS. bsolute Max ON urrent 150 mps 100% duty cycle 65 ambient to 60 Vdc and 24 V control input. 240 mps 5% duty cycle, to 55 ambient, 24 Vdc 24 V control input. Max pulse width 10 seconds. Max On Resistance (@ 10 amps) 0.001 Ohms terminal to parallel & ontrol Input urrent 0.01 mps (with 24 Vdc input) typical Switch on transient time Tr 5-8 ms typical, with 24 Vdc ontrol input Switch off transient time Tf < 0.3 ms typical SSR-15240-60V-12: Same specs except the ontrol input voltage is a nominal 12 Vdc. (9-16 Vdc) Note: Specifications are subject to change without notice. Rev. Page 7

Hellroaring SSR-15240-60V-xx Instructions Standard Terms and onditions of Sale The sale of Hellroaring Technologies, inc. products shall be governed by the laws of the state of Montana. ll sales shall transfer title within the state of Montana via common carrier. Hellroaring Technologies, inc. will not collect sales taxes for any other state. Should the unlikely event, a cause of action arises, buyer agrees that such action shall be held and governed in the state of Montana. The buyer recognizes that there exists inherent risks associated with batteries and installation & operation of battery devices. It is understood that any technical information published by Hellroaring Technologies, inc. including any installation instructions is of a general nature only and it is the user's responsibility to determine the proper application, installation, and operation of products. The buyer assumes all risk and agrees to indemnify Hellroaring Technologies, inc. against any and all causes for injury or damage to third parties that arises from use of such product. Return Policy Should any single unit product sold by Hellroaring Technologies, inc. not meet or exceed your expectations, you may, within 30 days of our shipment to you, return such product for a full refund (credit on credit card orders) less a 15% restock charge, provided that: a) You obtain an RM number and provide your shipping address by calling customer service at 406 883-3801 or send an RM request via e- mail (include the model #, serial number, and your phone number), and b) The product, including all accessories, is returned in original and re-saleable condition, and c) Units are Shipped (prepaid and insured for damage in transit) in the original or equivalent packaging, and d) (optional) You include a simple note as to the reason for dissatisfaction. (This can help us improve our products) For quantity orders, sales are final and our standard limited warranty applies. Limited Warranty This Limited Warranty is extended to the original purchaser. Hellroaring Technologies, inc. warrants that our SSR products will be free from defects in materials and workmanship upon delivery. ll claims for defects must be made within 30 days of delivery. The sole and exclusive remedy for failure of the product shall be for us, at our option, to repair or replace the product, to whatever extent we deem necessary to restore the product to proper operating condition. We may make replacements with new or functionally equivalent products of equal value. Should Hellroaring Technologies, inc. be unable to repair or replace the product within a reasonable time, we reserve the right, at our option, to issue a refund or credit of the purchase price in lieu of repair or replacement. We reserve the right to assess a $15 fee for units returned and proven not to be defective. To obtain warranty service you must: 1) all ustomer Service at 406-883-3801 for a Return Material uthorization (RM) number and shipping address. Or send an RM request via e-mail (include the model #, serial number, and your phone number and your return shipping address) 2) Return the product in the original or equivalent packaging (Shipping prepaid and insured for damage in transit), together with the RM number ND a description of the problem. Include your return shipping address and your phone number. Do not attempt to disassemble, or otherwise tamper with any of the 4 nuts on the bottom of each unit. Doing so will void this limited warranty. For quantity orders, extended warranty for switching applications may be available on an application specific basis at slight extra cost. Exclusions This Limited Warranty is made expressly in lieu of and to the exclusion of any and all warranties, express or implied, oral or written, including, without limitation, any and all implied warranties of merchantability or fitness for a particular purpose, and all such other warranties are expressly disclaimed. This Limited Warranty shall not be applicable to failures of the product that result from accident, abuse, misapplication or alteration, improper installation or maintenance, unauthorized repair attempts, operation or attempts to operate it beyond its mechanical, chemical, thermal, or electrical capacity intentionally or otherwise, and we assume no liability as a consequence of such events under the terms of this warranty. Hellroaring Technologies, inc. shall not be liable for any special, indirect, incidental, consequential, exemplary, or punitive damages for claims in any claim, action, suit or proceeding arising out of the purchase, use or performance of the product, and whether or not it has been advised of the possibility of such damages. The foregoing allocation of risk is reflected in the price of the product. Nor shall there be any liability thereunder for claims of labor, loss, profit, goodwill, repairs or other expenses incidental to the repair or replacement of such product. Hellroaring Technologies, inc. Rev. Page 8