Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Similar documents
Mechatronic pressure measurement. Applications. Special features. Description

Resistance thermometer Model TR30, compact design

High-quality pressure transmitter For general industrial applications Model S-10

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Pressure transmitter For general industrial applications Model A-10

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Indicator for panel mounting Model

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Field indicator for current loops with HART communication Models DIH50, DIH52

Float switch For industrial applications, plastic version Model RLS-2000

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Resistance thermometer Model TR30, compact design

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Resistance thermometer Model TR31, miniature design

Pressure transmitter For sanitary applications Model SA-11

Air flow meter For ventilation and air-conditioning Model A2G-25

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Flush pressure transmitter For viscous and solids-containing media Model S-11

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

OEM pressure transmitter For mobile working machines Model MH-3

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Pressure transmitter For general industrial applications Model A-10

Electronic temperature switch with display Model TSD-30

Field indicator for current loops with HART communication Models DIH50, DIH52

Digital indicator for panel mounting With multi-function input Model DI25

Pressure transmitter for general industrial applications Model A-10

High-quality pressure transmitter For general industrial applications Model S-20

In-line resistance thermometer Model TR25

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter for general industrial applications Model A-10

Submersible pressure sensor For superior applications Model LF-1

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Resistance Thermometers Model Series TR7X0, Sheathed Design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

ED701 General Industry Pressure Transmitter

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

OEM radar transmitter, for aggressive media level measurement

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

OPTIFLUX 5000 Technical Datasheet

In-Line Resistance Thermometers Model TR25

OPTIFLUX 5000 Technical Datasheet

Coriolis Massflowmeter

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

SALES SERVICE +358 (0)

Hand-held temperature calibrator Model CEP3000

HART field temperature transmitter Models TIF50, TIF52, TIF62

KFS. Flap-type flow meter. Design and range of application

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Coriolis Massflowmeter

Ultrasonic level measuring device, non-contact

Design and applications

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Positioner with HART Communication Type 3780

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Standard Bourdon tube pressure gauges EN 837-1

TMU. Coriolis Mass Flow Meter. for liquids and gas

KINAX SR 719 Programmable Transmitter for Position Feedback

Primary-standard resistance thermometry bridge Model CTR9000

Digital inductive conductivity transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

High-precision process calibrator Model CED7000

OPTIFLUX 1000 Technical Datasheet

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

Pressure transmitter AKS 32 and AKS 33

2/2 way Proportional Valve (motordriven)

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Rudder or propeller angular position transmitter KINAX WT720

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Operating Manual. Differential Pressure Transmitter DPS 100

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Transcription:

Mechatronic pressure measurement Absolute pressure gauge with output signal For the process industry Models APGT43.100 and APGT43.160, NS 100 and 160 k Applications for further approvals see page 4 WIKA data sheet PV 15.02 Acquisition and display of process values Output signals 4... 20 ma, 0... 20 ma, 0... 10 V for the transmission of process values to the control room Pressure measurement independent of fluctuations in the atmospheric pressure Monitoring of vacuum pumps and packing machines Measurement of condensation pressures and determination of vapour pressure in liquids Special features No configuration necessary due to plug-and-play Scale ranges from 0 25 mbar absolute pressure Easy-to-read analogue display with nominal sizes 100 and 160 High overload safety, long service life due to metallic media chamber sealing Media chamber protected against unauthorised access Absolute pressure gauge model APGT43.100 Description The model APGT43 intelligauge (US patent no. 8,030,990) can be used wherever pressure measurement has to be independent of fluctuations in the atmospheric pressure. The instrument serves for the on-site display with a simultaneous signal transmission to a central control or remote centre. Through the combination of a high-quality mechanical measuring system and precise electronic signal processing, the process pressure can be read securely, even if the voltage supply is lost. The intelligauge model APGT43.1x0 fulfils all safety-related requirements of the relevant standards and regulations for the on-site display of the working pressure of pressure vessels. An additional measuring point for mechanical pressure display can thus be saved. The model APGT43 is based upon a model 532.54 high-quality, stainless steel pressure gauge with a nominal size of 100 or 160. The pressure measuring instrument is manufactured in accordance with DIN 16002. The robust diaphragm measuring system produces a pointer rotation proportional to the pressure. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal proportional to the pressure, e.g. 4... 20 ma, is produced. The electronic WIKA sensor, integrated into the high-quality absolute pressure gauge, combines the advantages of electrical signal transmission with the advantages of a local mechanical display. The measuring span (electrical output signal) is adjusted automatically along with the mechanical display, i.e. the scale over the full display range corresponds to 4... 20 ma. The electrical zero point can also be set manually. WIKA data sheet PV 15.02 08/2017 Page 1 of 5

Specifications Mechanical data Mechanical version Safety pressure gauge S3 with solid baffle wall and blow-out back per DIN 16002 Nominal size in mm 100, 160 Accuracy (mechanical display) 2.5 % of measuring span (class 2.5 per DIN 16002) The measurement accuracy is ensured for ambient pressure fluctuations between 955 and 1,065 mbar (min. and max. of atmospheric pressure). Scale ranges 0... 25 mbar to 0... 25 bar absolute pressure Process connection Stainless steel 316L, G ½ B (male) (others as options) Operating limits Overload resistance per EN 837-3 Pressure limitation Steady Full scale value Fluctuating 0.9 x full scale value Observe the recommendations for the use of mechanical pressure measuring systems in accordance with EN 837-2 Overload safety Minimum 1 bar absolute pressure (atmospheric pressure), in addition 10 x full scale value, max. 25 bar absolute pressure Pressure element 0.25 bar: Stainless steel 316Ti (1.4571) > 0.25 bar: NiCr-alloy (Inconel) Movement Brass Dial Aluminium, white, black lettering Pointer Adjustable pointer, aluminium, black Standard pointer, aluminium, black (for models with liquid filling) Case Stainless steel, safety version with solid baffle wall (Solidfront) and blow-out back, scale ranges 0... 16 bar with compensating valve to vent case Window Laminated safety glass Ring Bayonet ring, stainless steel Damping options For dynam. pressure load Restrictor in the pressure port For vibration Liquid filling of the case Permissible temperature range Medium -20... +100 C Ambient -20... +60 C (with window from polycarbonate max. 80 C) Temperature effect max. ±0.8 %/10 K of full scale value (when the temperature deviates from 20 C reference temperature) Case ingress protection IP54 per IEC/EN 60529 (with liquid filling IP65) Options Other process connection Sealings (model 910.17, see data sheet AC 09.08) Max. medium temperature +200 C Higher indication accuracy Output signal 0... 20 ma, 0... 10 V Wetted parts from Monel Open connecting flange DN 15/50 PN 16/40 (wetted) Small flange for vacuum applications DN 10/32 DIN 28403 (wetted) Panel or surface mounting flange (consider measuring cell) Instrument mounting bracket for wall or pipe mounting (see data sheet AC 09.07) Filling liquid silicone M50 Window from polycarbonate (max. ambient temperature 80 C) Overload safety: > 10 x full scale value ATEX variant: Additionally suitable for mounting to zone 0 (also in conjunction with inductive contact model 831) Absolute pressure gauge with switch contacts, see data sheet PV 25.02 Page 2 of 5 WIKA data sheet PV 15.02 08/2017

Electrical data Power supply U B DC 12 V < U B 30 V (variant 1 + 3) DC 14 V < U B 30 V (variant 2) DC 15 V < U B 30 V (variant 4) Influence of power supply 0.1 % of full scale/10 V Permissible residual ripple of U B 10 % ss Output signal Variant 1: 4 20 ma, 2-wire, passive, per NAMUR NE 43 Variant 2: 4... 20 ma, per ATEX Variant 3: 0... 20 ma, 3-wire Variant 4: 0... 10 V, 3-wire Permissible max. load R A Variant 1, 2, 3: R A (U B - 12 V)/0.02 A with R A in Ohm und U B in Volt, however max. 600 Ω Variant 4: R A = 100 kω Effect of load (variant 1-3) 0.1 % of full scale Impedance at voltage output 0.5 Ω Electrical zero point Through a jumper across terminals 5 and 6 (see operating instructions) Long-term stability of electronics < 0.3 % of full scale per year Electr. output signal 1 % of measuring span Linear error 1 % of measuring span (terminal method) Resolution 0.13 % of full scale (10 bit resolution at 360 ) Refresh rate (measuring rate) 600 ms Maximum values for the power supply circuit (only for Ex version) Power supply U i DC 30 V Short-circuit current I i 100 ma Power P i 1 W Internal capacitance C i 12 nf Internal inductance L i Negligible Electrical connection Via angular connector, 180 rotatable, wire protection, cable gland M20 x 1.5, incl. strain relief, connection cable: Outer diameter 7... 13 mm, conductor cross-section 0.14... 1.5 mm 2, temperature resistance up to 60 C Designation of connection terminals, 2-wire (variant 1 and 2) Do not use this terminal U B +/I+ Terminals 3 and 4: For internal use only Terminals 5 and 6: Reset zero point Designation of connection terminals for 3-wire (variant 3 and 4), see operating instructions +0 V/GND Cable connection Angular connector from PA6, black, IP65, max. 1.5 mm 2 Cable gland M20 x 1.5 WIKA data sheet PV 15.02 08/2017 Page 3 of 5

Design and operating principle The diaphragm (1) separates the media chamber (3) and the reference pressure chamber (2) with absolute pressure zero Pressure differential between media chamber (3) and reference pressure chamber (2) will deflect the diaphragm (1) Illustration of the principle 289752.01 In case of an overpressure overload the pressure element will be protected by a contoured metal bolster The deflection is transferred from the pressure chambers through bellows or corrugated tubes (4), transmitted to the movement via the link (5) and indicated (evacuated) Approvals Logo Description Country EU declaration of conformity EMC directive ATEX directive (option) European Union EAC (option) EMC directive Pressure equipment directive Low voltage directive Hazardous areas GOST (option) KazInMetr (option) - MTSCHS (option) Permission for commissioning UkrSEPRO (option) DNOP (MakNII) (option) Hazardous areas Uzstandard (option) - CRN Safety (e.g. electr. safety, overpressure,...) Eurasian Economic Community Russia Kazakhstan Kazakhstan Ukraine Ukraine Uzbekistan Canada Certificates (option) 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) 3.1 inspection certificate per EN 10204 (e.g. indication accuracy) Approvals and certificates, see website Page 4 of 5 WIKA data sheet PV 15.02 08/2017

Dimensions in mm Standard version 11339927.01 NS Scale range Dimensions in mm Weight in kg in bar a b c d 1 d 2 D 1 D 2 e f G h ±1 SW 100 0.25 25 59.5 94 133 26 101 99 17 58 G ½ B 185 22 1.8 100 > 0.25 25 59.5 94 76 26 101 99 17 66 G ½ B 177 22 1.2 160 0.25 25 65 124 133 26 161 159 17 58 G ½ B 215 22 2.3 160 > 0.25 25 65 124 76 26 161 159 17 66 G ½ B 207 22 1.6 Process connection per EN 837-3/7.3 Ordering information Model / Scale range / Process connection / Connection location / Options 08/2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 08/2017 EN WIKA data sheet PV 15.02 08/2017 Page 5 of 5 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de