ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

Similar documents
ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

Electrosurgery. maxium INGENUITY IS ALWAYS QUITE SIMPLE

EXCELL NHP/T. A new step AheAd to the future ELECTROSURGICAL UNITS FOR MONOPOLAR AND BIPOLAR USE ISO ALSA IT ISO

OPERATING MANUAL ELECTROSURGICAL UNIT

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

HF- GENERATORS.

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

surtron.com SURTRON ELECTROSURGICAL units

OPERATING MANUAL ELECTROSURGICAL UNIT

ERBE. ERBOTOM ICC 80 / 50 Instruction manual 08.00

Electrosurgery Units (ESU s) and their variants

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

ERBE ERBOTOM ICC 300. Instruction manual 08.00

ELEKTROTOM 505. Service Manual (E)

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Neurosurgery with ultrasonic technology by Söring: fine preparation and effective dissection

Andy Falconer. Principles of surgical diathermy

USER S GUIDE. User s Guide Bovie IDS-400

Meg1 (with Ligasmart)

What tests should be done?

ELECTROSURGICAL GENERATOR USER S GUIDE

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

QA-ES III Electrosurgical Analyzer

Application Notes. Electrosurgical Analyzer Primer

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

QA-ES III Electrosurgical Analyzer

Leksell Neuro Generator

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

Optimized for perfection.

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

User s Guide Aaron 940

perioperativecpd.com The basics of diathermy

OPERATING MANUAL ELECTROSURGICAL UNIT

TL3000 Ceiling Mount as the Quickest Way to Take High-Precision X-Rays

Our combined competences in medical endoscopy systems provide global solutions. From

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

INSTRUCTIONS ESG-400

Content. User Instruction - Pointoselect digital. Intended use...3 Safe usage of the device...3 Description...4

Crossfire Footswitch. User Guide

MICRO-TECH Disposable biopsy forceps.

ELEKTROTOM 610. Service Manual. Valid from version 1132

DSL# EC 2009 Ethicon Endo-Surgery. All rights reserved PRODUCT CATALOG

ERCP Papillotomes, balloons, guide wires and baskets.

Moving Test - MT3000

Equine Laparoscopy Set by Mariën

DECLARATION OF CONFORMITY

GYN / US. VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room

User s Guide Aaron 950

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

QUICK SETUP GUIDE SECULIFE ESPRO

Radio Frequency Electrosurgical System Specialist

Operator s Manual E L E C T R O S U R G I C A L U N I T

Miscellaneous Accessories and technical equipment.

RF leakage current in electrosurgical units: Influence of the layout in taking measurements

BM VET 80, 120, 140, 180 W

User Manual CTP4/8/16

Fault location on power cables. Fault location on power cables

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

T CaRe ENERGY MADE TO MEASURE

innovative surgery sonoca-300 Ultrasonic dissector with integrated aspiration and irrigation pump

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Process: DC TIG (GTAW) AC TIG (GTAW) Input Power: 230V, 1-Phase Amperage Range: A Rated Output at40 C (104 F): Maintenance and Repair

METRATESTER 5+ Tester for DIN VDE /6.15

NOVASTICK A competitive proposal for most market requires. Applications

Wide range in small dimensions

The TIG AC/DC specialists

maxium electrosurgery unit with maxium Beamer

Diamond-Gerjy Proktoskop

DERM 941 DERM 942 High-Frequency Desiccators

ARCMASTER. 401MST Multi-Process Inverter Power Source Part No. W

Low / Medium Power Electrosurgery Review 2002

DRAFT. Crossfire 2 REF

Development of the Miniaturised Endoscope Holder LER (Light. Endoscope Robot) for Laparoscopic Surgery

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

TruHeat HF Series Unrivaled performance for superior induction processes.

Instruction Manual. (English-English)

Multi-electrode Conductivity Analyzers

MIG - TIG - PLASMA - MMA

Instructions for use

SPECIFICATION NO Model Automatic GTAW Welding System

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Aquamantys 3 Pump Generator User Guide. Revision F

Surgitron Dual Frequency 4.0 MHz Radiowave Technology

Technical data ESA614 Electrical Safety Analyzer

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Processes MIG (GMAW) Flux-cored (FCAW) DC stick (SMAW) AC/DC TIG (GTAW) Pulsed TIG (GTAW-P)

MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System

IZT R3600. Product Brochure. Version 1.1

Green LED (right of 'D' type connector)

SERIES 200TIG/250TIG

Operating Manual D-ACTOR 100

Simplicity. Reliability. Performance. ProdigyPlus

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

Processes MIG (GMAW) Flux-cored (FCAW) AC/DC TIG (GTAW) Pulsed TIG (GTAW-P) DC stick (SMAW)

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

Robotic Surgical Advances for Prostatectomies

Primare A31.2 Amplifier User Guide

Transcription:

BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4 10 72810 Gomaringen I Germany Phone +49 (0)7072-6002-0 Fax +49 (0)7072-6002-33 info@bowa-medical.com I bowa-medical.com 10752 4 03/09 Printed in Germany Technische und konstruktive Änderungen vorbehalten / subject to technical and design modification Copyright by BOWA-electronic, Gomaringen, GERMANY ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

As well as 20 years of BOWA experience in the sector and the most up-to-date technology, the ARC 350 all-in-one unit also incorporates clever innovations. All settings for more than 20 standard operations are pre-programmed - and updates are continuously being added. Inside, extremely fast processors ensure that Fast: The ARC CONTROL regulator adjusts the power output to the necessary minimum for tissue variations and changes in cutting area or speed in every case. Safe: The EASY electrode application system monitors the neutral electrode connected to the patient and signals any change in resistance to the user. Clever: The continuous self-test program ISSys monitors all safety-related parameters several hundred times a second and signals any faults. the ARC CONTROL is optimally integrated at all times, while self-check programs continuously provide maximum safety. Four separate outputs can be individually configured with the utmost ease, and the settings visually checked by the operator at any time. Flexible: 2 monopolar and 2 bipolar outputs enable 4 different instruments to be configured independently. Convenient: More than 20 of the 100 locations for storing programs are already preprogrammed. They can be shown and hidden as well as named individually. Information can be displayed in different languages as required. 3 Field of application Bronchoscopy Cardiology ENT surgery Gastroenterology General surgery Gynaecology Laparoscopy Liver surgery Neuro surgery Paediatrics Plastic surgery Thorax surgery Urology Program Argon Flex DryCUT, Mamaria, SimCOAG, Thorax ENT Argon Flex, GastroCUT (Polypectomy, Papillotomy) Argon Ligation, Argon Open, Ligation, Standard Abdominal Ligation, EndoLAP, Hystero EndoLAP Bipolar CUT, EndoLAP II Ligation Argon Open, Argon Ligation Micro Neuro Micro Pediatric Micro Plastic, Macro Plastic, Local Anesthesia EndoLAP II Ligation, Thorax TUR-P, TUR-BT, TUR-VAP, Bipolar TUR Simply more to offer: ARC 350

Fast: ARC CONTROL Convenient: 100 programs Clever: Continuous self-test Clearly laid out: Settings at a glance Safe: Patient monitoring Innovative: High-tech inner workings Flexible: Outputs for 4 instruments ARC 350: REF 900-350 MADE IN GERMANY

GOOD DESIGN In the 350L version, ARC provides three optional Ligation programs and the associated special instruments for sealing vessels and tissue bundles in both open and laparoscopic surgery - TissueSeal and LIGATOR, which have received the red dot design award for their ergonomic and mechanical ingenuity. The LIGATION program enables even large veins, arteries and bunched tissue to be continuously sealed and provides the surgeon with different shaped instrument tips depending on the situation. The tissue sealing option can therefore be carried out without additional equipment, and an adapter enables third-party accessories to be used for this application. 5 Fields of application for TissueSeal (extract) Adhesiolysis Adrenalectomy Colon resection Cystectomy Gastrectomy General surgery Gynaecology Haemorrhoidectomy Hysterectomy Nephrectomy Pancreasectomy Prostatectomy Salpingoophorectomy Spleenectomy Urology Fields of application LIGATOR (extract) Adhesiolysis Adrenalectomy Appendectomy Cholecystectomy Fundoplicatio Gastrectomy Gynaecology Hysterectomy Nephrectomy Salpingoophorectomy Spleenectomy AWARD 2008 TissueSeal LIGATOR Gripping: LIGATION option with ARC 350L

BOWA also provides practical thinking in the areas of gastroenterology, cardiology and urology. Sophisticated programs save the operator the trouble of manually pre-setting the equipment. This saves time, avoids incorrect settings and thus enables the operating team to concentrate fully on the operation. Gastroenterology programs ARC 350 has three programs for gastroenterological operations: polypectomy, papillotomy and argon plasma coagulation. The combination of cutting and coagulation current gives optimum results when using polypectomy loops or papillotomes. TUR for urology Three special programs are available for urologists for underwater cutting: TUR-P for prostate resection, TUR-VAP for vaporising prostate tissue, and TUR-BT for treating vesical tumours. All three special programs may be operated in the Bipolar TUR mode. Cardiology ARC 350 already has four programs with special cutting current for cardiology (DryCUT, SimCOAG, Thorax, Mamaria). Two handles can be activated simultaneously with SimCOAG. 7 Gastroenterology programs Urology programs Cardiology programs GastroCUT (polypectomy) TUR-P (prostate resection) DryCUT GastroCUT (papillotomy) TUR-BT (vesical tumours) SimCOAG Argon Flex TUR-VAP (vaporisation) Thorax Bipolar TUR Mamaria Special programs for gastroenterologists, cardiologists and urologists

ARC PLUS ideally complements the ARC range of HF generators with its argon gas technology. Argon-assisted HF spray coagulation can even work reliably with arcs in the extremely low power range of less than 10 watts. As a result of their low coagulation depth, they only cause minimal necrosis of the tissue, which favours their use in areas at risk of perforation. The non-contact method of working also prevents electrodes sticking. Two ranges are available for the use of different argon accessories. In a high-performance combination with the ARC PLUS, the ARC 350 provides even more: namely two further individually configurable outputs. The possible applications of ARC are considerably enhanced by the argon-assisted non-contact HF spray coagulation options. Fields of application (extract) Argon Open, Argon Ligation Abdominal plastic surgery ENT General surgery Liver surgery Transplantation surgery Argon Flex Bronchoscopy Gastroenterology Rectoscopy 9 Igniting PLUS with argon assistance

Safety: Continuous self-test Operation: Simple and safe Ignition: Reliable at less than 10 watts Endurance: Bottle and spare bottle ARC PLUS: REF 900-000 ARC 350: REF 900-350 MADE IN GERMANY

BOWA knows what surgeons need inside out. This knowledge is invaluable when it comes to developing accessories for monopolar and bipolar laparoscopic HF surgery. This is how the ErgoLAP accessory range with its futureorientated functionality, design and ergonomics came into being. The surgeon uses the accessories without tiring and always has a tactile feel for the action of the instrument tip, which is equipped with the appropriate jaws for each required operation. The easily dismantled accessories can be autoclaved and can be used several hundred times. 11 Programs EndoLAP, Bipolar CUT EndoLAP II Ligation Gynaecology Abdominal Fields of application (extract) Adhesiolysis Adrenalectomy Appendectomy Cholecystectomy Gastrectomy Gynaecology Hysterectomy Nephrectomy Fundoplicatio Salpingoophorectomy Spleenectomy ErgoLAP BIPOLAR Hand tools for minimally invasive artists

Technical specification for the ARC 350 12 BOWA ARC 350 units can be used in all areas of HF surgery. They can be located both on ceiling supply units and also on a mobile ARC CART, without or in combination with an argon unit. The 2 monopolar and 2 bipolar outputs provided form a modular socket system. The unit complies with the currently required applicable standards and can be maintained by the hospital technician himself. Error memories can be read out without difficulty. The technician can update software simply by changing a board and subsequently calibrating the unit. Third-party accessories can be connected with the help of adapters. Maximum cutting power / short-term Number of types of cutting current Number of types of coagulation current ARC CONTROL via 32 bit microcontroller (RISC) Number of displays / indicators 7 Number of foot switches 2 Digital set-up Auto Start function for both bipolar outputs 300 / 420 watts 82 (of which 62 monopolar) 27 (of which 7 bipolar) ARC CONTROL for monopolar and bipolar cutting Neutral electrode monitoring (EASY) Impedance window for NE-monitoring EASY monitoring frequency Continuous system self-test (ISSys) Error memory Error documentation display Arc suppression for contact coagulation Continuous Cut Support (CCS) Continuous leakage current monitoring Defibrillator checked 0 200 ohms 44 khz Compendium: Technical specification HF electrosurgical generator ARC 350 Max. output power for monopolar Cut 300 watts Simply check: Facts & Figures

Technical specification for ARC PLUS Max. output power for monopolar Coag Max. output power for bipolar Cut Max. output power for bipolar Coag NE safety monitoring Rated frequency 120 watts 150 watts / Bipolar TUR 380 watts 120 watts / Ligation & Bipolar TUR 200 watts EASY 330 khz / 1MHz Mains connection/max. current consumption 90 V 110 V / 6,4 A 100 V 130 V / 6,4 A 198 V 260 V / 3,2 A Mains fuse 2 x 8 A / (90 V 110 V) 2 x 8 A / (100 V 130 V) 2 x 4 A / (198 V 260 V) Mains frequency 50 / 60 Hz Power consumption in standby mode 25 watts Max. power consumption at max HF power 500 watts Equipotential bonding connector Width x Height x Depth 430 x 180 x 400 mm Weight ca. 14 kg Storage and transport conditions Temperature Relative humidity Air pressure Operating conditions Temperature Relative humidity Air pressure Protection class to EN 60601-1 Type according to EN 60601-1 Operating mode Classification according to EC Directive 93/42/ EEC 20 C to +50 C 0 to 75 %, non condensing 500 to 1600 mbar 10 C to +40 C 30 to 85 %, non-condensing 700 to 1600 mbar I CF 10 sec / 30 sec Class IIb BOWA ARC PLUS can be used in all areas of HF surgery in combination with all ARC generators. It can be located both on ceiling supply units and also on a mobile ARC CART. The communications interface provided continuously monitors the interaction with the ARC generator. The unit complies with the currently required applicable standards and Gas supply Gas type Adjustment range Adjustment range Adjustment range Gas input pressure Max. gas output pressure - Two gas tank connections, automatic or manual changeover of gas tanks and optical level indicator - PURGE rinsing function with electrodedependent gas pressure control - Safety devices - Continuous flow monitoring, fault indication with display of error number, hose blockage detection, continuous self-test, warning tone, continuous pressure monitoring at distal end Mains connection Power consumption Mains frequency Equipotential bonding connector Voltage range Dimensions and weights External dimensions (W x H x D) Net weight Protection class to EN 60601-1 Type according to EN 60601-1 Classification according to EC Directive 93/42/EEC can be maintained by the hospital technician himself without special measuring equipment. Fault memories can be read out without difficulty. The technician can update software simply by changing a board and subsequently calibrating the unit. Argon Purity 4.8 or better, Class 2.1 A 0,1 to 1,0 l/min, Adjustment step 0,1 l/min 1,0 to 3,0 l/min, Adjustment step 0,2 l/min 3,0 to 9,5 l/min, Adjustment step 0,5 l/min between 2,5 and 4,5 bar 2 bar - Documentation - Recording of fault conditions and operator errors by storing within the unit Data recall facility - Connections, Communication - Optical interface for communication with ARC 350 40 VA 50 / 60 Hz 85 bis 264 V A.C. 430 x 94 x 400 mm ca. 7,3 kg I CF in conjunction with ARC 3x0 Class IIa

The ARC 350 and ARC PLUS are often combined to form an unbeatable all-in-one package, which can be conveniently located on the BOWA ARC CART or on ceiling supply units. 15 The ARC CART can be configured individually, e.g. shelves, drawer, basket, gas tank holder. The whole range of foot switches has ergonomically arranged pedals. For even greater potential