TUE ~CCT Controllable~ Specification Product ame Model o. VT0750XXA (750mm) TUE (Apprx.14W/meter at maximum output) VT0380XXA (380mm) VT1120XXA (1120mm) Builttoorder Input Voltage Power Consumption 10.6W (Apprx.14W/meter) 24.0Vdc (TDK lambda recomended) 5.3W (Apprx 14W/meter) 15.9W (Apprx 14W/meter) Dimension (mm) 750*19*14(H) 380*19*14(H) 1120*19*14(H) Casing Body Aluminum extrusion heatsink with semifrost polycarbonate cover Weight 130 grams 68 grams 200 grams ED Beam Angle Operating Temperature Max.length of series connection Option parts 120 10 ~45 6 meter Mounting clip bracket 0deg(flat) type, Malefemale/Plugin connector os of EDs 24 12 36 Power Supply Unit Dimming Control umens in CCT3000K 24.0Vdc ConstantVoltage Switching Power supply ( TDK ambda brand recommended) 〇 With recommended 010V/DMX compatible dimming driver unit ( For detail, see page 33) 480 (approx640m/meter) 240 (apprx640m/meter) 720 (apprx640m/meter) Available ED Colour Daylight 6500K ot Applicable ot Applicable ot Applicable Cool white 4000K ot Applicable ot Applicable ot Applicable 3500K ot Applicable ot Applicable ot Applicable ight Warm 3000K ot Applicable ot Applicable ot Applicable Standard Warm 2700K ot Applicable ot Applicable ot Applicable Dark Warm 2400K ot Applicable ot Applicable ot Applicable RGB Full Colour ot Available
Option Accessories Mounting Clip Bracket 0deg Flat Type for TUE / or ECOBAR Model: MC0DEGEB W22mm (max.point) Fixture profile can be fit within the dimensions H18mm (max.point) 10mm Clip (plugin) Connector Presoldering to fixture can be done on "Builttoorder" basis. 5.5mm (at max.point) 25.8mm Photometrics IES OT AVAIABE YET COMIG SOO V TUE (750mm) Model: VT0750XXA When set at CCT 3000K For IES data, please contact our sales staff or distributor
TUE ~CCT COTROABE~ Application Guide シチュエーションに応じた光色制御 10m 3800K~4500K (Daylight / Cool White) 3500K~3000K ( 温白色 ) ight Warm white 2800K~2400K ( 電球色 ) Warm white 勉強 読書に適した明かり Studying Reading 3800K~4500K の白い光は脳を覚醒させ活動 作業の空間に適しています Application Example だんらん TV 鑑賞 ダイニング TV watching Dining Family time 少し温かみのある光色で落ち着いた雰囲気に リラックス時 就寝前 Relaxing Befofre sleeping 温かみのある光色で一日の疲れを癒しくつろぎの空間を演出します Master iving Room Private Residence
TUE ~with CCT Control System~ 1Channel Case (input) (output) 110V Electronic Potentiometer with switch control "OSRAM's MCU" / or 110V DIMMIG SYSTEM F ACDC Switching PSU G "DC I" (GD) GD 1) OnOff switching by pushing this 2) Rotating the tab clockwise Tuning to cooler colour 3) Rotating the tab anticlockwise Tuning to warmer colour 010 VRDIMMER (max. 6A) 110V signal() Red wire coming from fixture is Plus () ED Fixture, 24Vdc spec W (Minus Wire forwarm White) Max oad 6A = ot more than 9meter OTE: Max nos of fixture in one series connection shall ot exceed 4meter Make sure polarity (plus & minus) of all DC/ED wires are correct before switching on. Take note that RED colour wire of TUE is positive () as common wire, and black colour wire is negative() for both Daylight and Warm white respectively. Reverse connection may damage ED circuit. CAUTIO 1 () D() W() Red wire = Plus (), Common wire Centre Black wire = Minus () for Daylight Black colour wire at the extreme edge = Minus() for Warm CAUTIO 2 For extension wire from switching power supply unit to ED, use AWG16(1.309mm2) or thicker wire, provided distance between power supply unit and 1st ED is within 6meter. Should distance between power supply unit and 1st ED exceeds 6meter, please consult us individually on casebycase basis, so that we will propose suitable wire gauge as well as wiring layout. CAUTIO 3 Depending on various type of nominal wattage for 24Vdc switching power supply unit, load ratio of ED must be properly calculated. Ideally ED load ratio should be controlled below 85% against nominal wattage of power supply unit based on indoor application where ambient temperature is set below 25deg. For example, if 150W 24Vdc power supply unit is used, maximum load shall be approx.127w (150W x 85%).
TUE ~with CCT Control System / DMX system~ 2Channel DMX Controller (512) DMX F ACDC Switching PSU (GD) DMX Data G "DC I" GD VRDIMMER (max. 6A) R B R Red wire coming from fixture is Plus () = Common wire ED Fixture, 24Vdc spec W (Minus Wire forwarm White) Max oad 6A = ot more than 9meter OTE: Max nos of fixture in one series connection shall ot exceed 4meter Make sure polarity (plus & minus) of all DC/ED wires are correct before switching on. Take note that RED colour wire of TUE is positive () as common wire, and black colour wire is negative() for both Daylight and Warm white respectively. Reverse connection may damage ED circuit. CAUTIO 1 () D() W() Red wire = Plus (), Common wire Centre Black wire = Minus () for Daylight Black colour wire at the extreme edge = Minus() for Warm CAUTIO 2 For extension wire from switching power supply unit to ED, use AWG16(1.309mm2) or thicker wire, provided distance between power supply unit and 1st ED is within 6meter. Should distance between power supply unit and 1st ED exceeds 6meter, please consult us individually on casebycase basis, so that we will propose suitable wire gauge as well as wiring layout. CAUTIO 3 Depending on various type of nominal wattage for 24Vdc switching power supply unit, load ratio of ED must be properly calculated. Ideally ED load ratio should be controlled below 85% against nominal wattage of power supply unit based on indoor application where ambient temperature is set below 25deg. For example, if 150W 24Vdc power supply unit is used, maximum load shall be approx.127w (150W x 85%).
TUE~with CCT Control System / DAI system~ 2Channel ACDC Switching PSU Data signal (DA) Data signal (DA) DAI System DAI System DA DA VDC VDC IEAR Drive 220D (max. 6A) Group 1 Grouip 2 ED Supply "DC I" Cable with Black Colour plugin Connector coming from ED Fixture is Plus () = Common wire ED Fixture, 24Vdc spec W (Minus Wire forwarm White) Max oad 6A = ot more than 9meter OTE: Max nos of fixture in one series connection shall ot exceed 4meter Make sure polarity (plus & minus) of all DC/ED wires are correct before switching on. Take note that RED colour wire of TUE is positive () as common wire, and black colour wire is negative() for both Daylight and Warm white respectively. Reverse connection may damage ED circuit. CAUTIO 1 () D() W() Red wire / or Cable with Black connector = Plus (), Common wire Centre Black wire = Minus () for Daylight Black colour wire at the extreme edge = Minus() for Warm white CAUTIO 2 For extension wire from switching power supply unit to ED, use AWG16(1.309mm2) or thicker wire, provided distance between power supply unit and 1st ED is within 6meter. Should distance between power supply unit and 1st ED exceeds 6meter, please consult us individually on casebycase basis, so that we will propose suitable wire gauge as well as wiring layout. CAUTIO 3 Depending on various type of nominal wattage for 24Vdc switching power supply unit, load ratio of ED must be properly calculated. Ideally ED load ratio should be controlled below 85% against nominal wattage of power supply unit based on indoor application where ambient temperature is set below 25deg. For example, if 150W 24Vdc power supply unit is used, maximum load shall be approx.127w (150W x 85%).
TUE ~with CCT Control System~ 2Channel Case / under 1(0)10V system ACDC Switching PSU 1(0)10V signal from 1(0)10system () = GD () GD 010 "DC I" VRDIMMER GD (max. 6A) ED Fixture, 24Vdc spec Max oad 6A = ot more than 9meter OTE: Max nos of fixture in one series connection shall ot exceed 4meter Red wire coming from fixture is Plus () 1(0)10V signal from 1(0)10 System D (Daylight ) () = GD () GD 010 VRDIMMER GD (max. 6A) "DC I" W (Warm White ) Make sure polarity (plus & minus) of all DC/ED wires are correct before switching on. Take note that RED colour wire of TUE is positive () as common wire, and black colour wire is negative() for both Daylight and Warm white respectively. Reverse connection may damage ED circuit. CAUTIO 1 () D() W() Red wire = Plus (), Common wire Centre wire = Minus () for Daylight Black/white colour wire at the extreme edge = Minus() for Warm CAUTIO 2 For extension wire from switching power supply unit to ED, use AWG16(1.309mm2) or thicker wire, provided distance between power supply unit and 1st ED is within 6meter. Should distance between power supply unit and 1st ED exceeds 6meter, please consult us individually on casebycase basis, so that we will propose suitable wire gauge as well as wiring layout. CAUTIO 3 Depending on various type of nominal wattage for 24Vdc switching power supply unit, load ratio of ED must be properly calculated. Ideally ED load ratio should be controlled below 85% against nominal wattage of power supply unit based on indoor application where ambient temperature is set below 25deg. For example, if 150W 24Vdc power supply unit is used, maximum load shall be approx.127w (150W x 85%).