Signal Beacon - LED Series 6162

Similar documents
Motor Protection Circuit Breaker Series 8146/5-V27

Actuators Series 8602/3

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

J: Emergency lighting (optional) L: pole type X: ceiling type

Sicherheit, auf die Sie sich verlassen können

Fieldbus Isolating Repeater Series 9185/11

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Digital I/O Coupler (4-wire) Series 9413/21

Isolators A3/1.

Two-channel safety barriers Series 9002

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Binary Output without Power Supply Series 9176

Two-channel safety barriers Series 9002

Digital Input Output Module for Zone 1 Series 9470/32

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

Binary Output Series 9175

Isolators A3/1.

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Single-Channel Safety Barriers Series 9001

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

Rudder or propeller angular position transmitter KINAX WT720

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Modular Beacon Series M

Digital Input Output Module for Zone 2 Series 9470/33

Local control stations for Zone 1 and Zone 21. Features. Description

Multiturn absolute encoder

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators A3/1. Vibration Transducer Supply Unit Series

Digital Input Output Module for Zone 2 Series 9470/33

Loud electronic horn High life duration up to 5,000 hrs TECHNICAL SPECIFICATIONS: PC, PC/ABS-Blend, grey Fixing:

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

Control Unit Series 8208

INSTRUCTION MANUAL (ATEX / IECEx)

BExCS / BExDCS110-05

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Sicherheit, auf die Sie sich verlassen können

Isolating Repeater Input Series 9163

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office:

Technical Data. General specifications. Rated operating distance s n 3 mm

For use in Flammable Gas and Dust Atmospheres

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

OPTIWAVE 1010 Technical Datasheet

Oil & Gas / Heavy Industry Type 2REX-A-NA-SSI

Mechatronic pressure measurement. Applications. Special features. Description

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Radar Scanner CRAT20-11/11 - normal beam angle - long range

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Alphino 5W2 Weather Proof Beacon Strobe Light

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Alphino 3W2 Weather Proof Beacon Strobe Light

Alphino 2W2 Weather Proof Beacon Strobe Light

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

iant101 Zone 1 Omni Directional Antenna

Ultrasonic level measuring device, non-contact

FOCAL ADVANTAGES DESCRIPTION CHARACTERISTICS

Ex-control switch Typ 294 without and Typ 295 with measuring instrument

BExBG05 Xenon Beacon The flameproof BExBG05 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications.

KINAX WT 717 Programmable Transmitter for Angular Position

Load cell. Special features. Data sheet

Remote I/O. 74 Remote I/O. Remote I/O System

Field indicator for current loops with HART communication Models DIH50, DIH52

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome

Material High-quality aluminium alloy High-quality aluminium alloy

Absolute Rotary Encoder EXAG Explosion Proof. Device Net

DATASHEET F090 - GENERAL PURPOSE INDICATOR

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Flow Measurement SITRANS F M

LED LL DP CD WW CS CF AC CG. Wall Washer CB LC FO EL

Product range Cable Glands

HEAVY DUTY 800 SERIES ENCODER MODELS 841, 850, 855, 861, 862, 865

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Description of equipment

Standard Halogen Light

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Absolute Rotary Encoder EXAG Explosion Proof. Canopen

In-line resistance thermometer Model TR25

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

370 SERIES SIGNAL TOWERS 370 SERIES Ø70

Field indicator for current loops with HART communication Models DIH50, DIH52

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

J; ('& ): J; )'& ): J; +'& ): J; +(+ ): J;,)& ): 9WXb[ i[j J;9JKI <_n_d] <P%' '& <_n_d] IP 7ii[cXbo 7Z`kijc[dj 9WbYkbWj_ed \ehckbwi

SYSTEMS AND PARTS EARTHING CONTROL: S604 & S804. Background. Product. Functioning SYSTEMS AND PARTS - EARTHING CONTROL

Transcription:

www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure with glass dome > Integrated Ex e connection chamber > Glass dome available in: signal yellow, red, amber and blue respc. clear > Available with 20 W / 35 W halogen bulb or as LED-continuous beacon / LED-rotating beacon 0614E00 The R. STAHL Signal Beacon is approved for use in Ex Zones 1, 2, 21 and 22. All models feature an integrated "increased safety" wiring space. The rotating mirror beacons and the rotating beacons have an integrated wear resistant friction gear which creates 180 light signals per minute. The wear-free LED beacons ensure an extremely high service life of up to 50,000 hours due to the innovative LED technology. In addition to the LED-continuous beacon, a LED-rotating beacon is also available. This LED-rotating beacon is maintenance-free thanks to the absence of any moving components. The robust, seawater resistant aluminium enclosure ensures IP66 protection for all models. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x WebCode 6162A Signalling Devices /1

Selection Table Version Rated operational voltage Lamp wattage Rotating mirror beacon Colour of glass Order number Art. no. Weight kg 24 V AC / DC, 35 W signal yellow 6162/1-62-111 219928 5.300 clear 6162/1-62-211 219930 5.300 red 6162/1-62-311 219934 5.300 blue 6162/1-62-411 219936 5.300 amber 6162/1-62-611 219938 5.300 green 6162/1-62-11 241480 5.300 115 V AC, 35 W signal yellow 6162/1-32-111 21989 5.300 clear 6162/1-32-211 219904 5.300 red 6162/1-32-311 219909 5.300 blue 6162/1-32-411 219910 5.300 amber 6162/1-32-611 219911 5.300 green 6162/1-32-11 24148 5.300 230 V AC, 35 W signal yellow 6162/1-12-111 219894 5.300 clear 6162/1-12-211 219896 5.300 red 6162/1-12-311 21989 5.300 blue 6162/1-12-411 21983 5.300 amber 6162/1-12-611 21984 5.300 green 6162/1-12-11 2414 5.300 Rotating beacon 24 V AC / DC, 35 W signal yellow 6162/18-62-111 219962 5.300 clear 6162/18-62-211 219963 5.300 red 6162/18-62-311 219964 5.300 blue 6162/18-62-411 219965 5.300 amber 6162/18-62-611 219966 5.300 green 6162/18-62-11 241535 5.300 115 V AC, 35 W signal yellow 6162/18-32-111 241523 5.300 clear 6162/18-32-211 241524 5.300 red 6162/18-32-311 241525 5.300 blue 6162/18-32-411 241526 5.300 amber 6162/18-32-611 24152 5.300 green 6162/18-32-11 241528 5.300 230 V AC, 35 W signal yellow 6162/18-12-111 219952 5.300 clear 6162/18-12-211 219953 5.300 red 6162/18-12-311 219954 5.300 blue 6162/18-12-411 219955 5.300 amber 6162/18-12-611 219956 5.300 green 6162/18-12-11 241522 5.300 /2 Signalling Devices

Selection Table Version Rated operational voltage Lamp Colour of glass Order number Art. no. Weight wattage kg Xenon Flashing 24 V AC / DC (± 15 %), 15 J signal yellow 6162/15-64-111 21998 5.300 beacon clear 6162/15-64-211 21999 5.300 red 6162/15-64-311 219800 5.300 blue 6162/15-64-411 219861 5.300 amber 6162/15-64-611 219862 5.300 110... 12 V AC, 230... 240 V AC, green 6162/15-64-11 21993 5.300 15 J signal yellow 6162/15-44-111 219851 5.300 clear 6162/15-44-211 21994 5.300 red 6162/15-44-311 21995 5.300 blue 6162/15-44-411 21996 5.300 amber 6162/15-44-611 2199 5.300 green 6162/15-44-11 21995 5.300 15 J signal yellow 6162/15-4-111 219863 5.300 clear 6162/15-4-211 219864 5.300 red 6162/15-4-311 219865 5.300 blue 6162/15-4-411 219866 5.300 amber 6162/15-4-611 21986 5.300 LED continuous beacon green 6162/15-4-11 21994 5.300 24 V DC 5 W signal yellow 6162/19-55-111 20189 5.300 red 6162/19-55-311 201880 5.300 115... 230 V AC, amber 6162/19-55-611 203036 5.300 5 W signal yellow 6162/19-95-111 201901 5.300 red 6162/19-95-311 219980 5.300 amber 6162/19-95-611 20303 5.300 LED rotating beacon 24 V DC 3.6 W signal yellow 6162/18-55-111 21992 5.300 red 6162/18-55-311 219959 5.300 amber 6162/18-55-611 219961 5.300 115... 230 V AC, 3.6 W signal yellow 6162/18-95-111 201903 5.300 red 6162/18-95-311 21995 5.300 amber 6162/18-95-611 21996 5.300 Note The optical beacons are supplied without mounting accessories and wire guard. These must be ordered separately! Signalling Devices /3

Explosion Protection Global (IECEx) Gas and dust IECEx PTB 06.008 Ex d e llc T3... T6 Gb* Ex tb lllc T80 C... T160 C Db* Europe (ATEX) Gas and dust PTB 06 ATEX 103 E ll 2 G Ex d e llc T3... T6 Gb* E ll 2 D Ex tb lllc T80 C... T160 C Db* * Temperature classes are dependent on lamp wattage (see product variant table) Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) Product variant table Version Power or Voltage Temperature class Max surface temperature Ambient temperature range Rotating mirror beacon 35 W T3 160 C -20... +50 C 20 W T4 115 C -20... +50 C Rotating beacon 35 W T4 115 C -20... +50 C 20 W T6 80 C -20... +40 C 20 W T5 90 C -20... +50 C Xenon beacon 24 V AC / DC, T5 95 C -20... +50 C with double flash 115 V AC, T5 90 C -20... +40 C 115 V AC, T4 100 C -20... +50 C 230 V AC, T5 95 C -20... +50 C Xenon flashing beacon 24 V AC / DC, T6 5 C -20... +50 C 110 12 V AC, T5 95 C -20... +40 C 110 12 V AC, T4 105 C -20... +50 C 230 240 V AC, T6 80 C -20... +50 C LED continuous beacon 24 V AC / DC, T6 80 C -20... +50 C / LED rotation beacon 24 V AC / DC, T5 90 C -20... +60 C 115 230 V AC, T6 80 C -20... +50 C 115 230 V AC, T5 90 C -20... +60 C Technical Data Electrical data Rated operational voltage Luminous characteristics Lamp wattage Rotation speed see selection table see selection table rotating mirror beacon: rotating beacon: 180 rpm 60 rpm Duty cycle 100% Service life rotating mirror beacon rotating beacon beacon with double flash flashing beacon LED-rotating beacon LED-continuous beacon 5000 h (drive) 5000 h (drive) 4x10 6 flashes 4x10 6 flashes max. 50 000 h max. 50 000 h Ambient conditions Ambient temperature see selection table /4 Signalling Devices

Technical Data Mechanical data Degree of protection IP66 Protection class I(acc. to IEC/EN 60598) Material Enclosure aluminium powder coated, seawater resistant Light dome glass, resistant to thermal shocks Wire guard stainless steel Seal NBR O-ring Mounting / Installation Cable entries 1 x M20 x 1.5 (d 4... 13 mm) 1 x M20 x 1.5 stopping plug metal cable gland on request Connection cross-section L1, N, PE 2.5 mm 2 finely-stranded 4 mm 2 solid Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Halogen lamp G6.35 20 W / 12 V 2 pc 120933 0.001 05003E00 20 W / 24 V 2 pc 35 W / 12 V 2 pc 120934 0.001 120935 0.001 35 W / 24 V 2 pc 120936 0.001 Mounting plate material: stainless steel, includes mounting screws, for wall or floor mounting 120821 0.158 0429E00 Pipe clamp R 2 120921 0.600 R 1 1 / 2 R 1 1 / 4 120920 0.560 120919 0.520 04223E00 Mounting bracket material: stainless steel, includes mounting screws 120930 0.450 04281E00 Wire guard material: stainless steel, includes mounting screws 12091 0.540 10289E00 Cable gland 8161/-M20-1304 50 pieces 4... 13 mm 2 (delivery lot *) ) 251549 Stopping plug 02055E00 04840E00 8290/3-M20 1 piece 143522 0.005 8290/3-M20 100 pieces 143543 0.500 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. Signalling Devices /5

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 336 X 32 316 32 12 95 32 15,50 6,50 Ø 210 M6 Ø 210 32 X 04282E00 Signal beacon Mounting accessories Y 1¼" (Ø 42) 1½" (Ø 48) 2" (Ø 60) 40 139 Y 106,25 1¼" - 184 1½" - 191 2" - 203 106,25 58 50 25 25 25 50 130 130 04333E00 04335E00 04595E00 Mounting bracket Pipe clamp Mounting plate We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Signalling Devices