Sample image ECG versions Model Order no. Output current 1) Output power CCD175-25FX-20/220-240/LI 10132980 100... 750 ma 2... 25 W 1) Adjustable by means of zitares360 software or resistor. Performance characteristics LI dimmable 1 channel ECG for constant current operation of LED modules SELV output voltage 60 VDC for simplified luminaire construction Highest possible flexibility thanks to adjustable output current in a wide range via Ωset or software zitares360 Very high energy efficiency of up to 87 % at maximum output load Lowest ripple of output current in high- and lowfrequency ranges for flicker- and glimmer-free light Flicker-free and noise-free dimming in the range 1... 100 % luminous flux (amplitude dimming) Push-Dim function for LI version: dimming and switching via push-button, with memory function Suitable for direct current operation and application in combination with central battery installations DC detection: via software zitares360 adjustable light level for DC operation ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload Certified as thermally protected ECG Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference Nominal service lifetime with a failure rate 10 %: 50,000 h at t c = t c,max Applications Office Industrial Shop Markings 110 Ω 1/7 1/8
General technical data Mains voltage supply Rated voltage range 220... 240 V Max. admissible voltage range (continuous) 198... 264 V Rated frequency 0 / 50... 60 Hz Suitable for fi xtures with protection class I, acc. to IEC 60598 3) Battery operation Voltage range for continuous operation 198... 278 VDC Lowest limiting value for temporary operation 176 VDC / 0.5 h Mains overvoltage Overvoltage protection 350 VAC / 2 h Automatic switch-off of the LEDs at appr. 290 VAC Emergency output factor (EOF I ) 2) 0,01... 1 Protection against voltage peaks Voltage peaks L - N 1 kv Voltage peaks L/N -PE 2 kv Starting time Time to 100% luminous fl ux < 0.5 s Total harmonic distortion (THD) At 100% load to ECG-output < 10 % Output data Tolerance of output current +/- 5 % Ripple of output current high frequency: +/- 10 % low frequency: +/- 1 % Max. wire length to LED module 2 m Galvanic separation to mains input yes, test voltage 3.75 kv U-OUT acc. to EN 61347-1 60 V Protection functions output side Overload operation yes, ECG switch-off; Restart after mains interruption Underload / Short-circuit operation yes, ECG switch-off; Restart after mains interruption Open-circuit operation yes, ECG switch-off; Restart after mains interruption Dimming operation and interface Overvoltage protection of interface 264 VAC Galvanic separation to output side yes, test voltage 3.75 kv Stand-by power losses 0.3 W Dimming range for luminous fl ux 1... 100 % Dimming technology Amplitude Number of ECG for Push-Dim control 25 Ωset interface Overvoltage protection of interface 60 VDC Connection terminals Type 90 - terminal with release hole 1) Wire cross section 0.5 mm² - 1.5 mm² Wire stripping length 8 mm - 9 mm Thermal protected device Max. surface temperature acc. to EN 61347-1/C5e + 110 C Degree of protection Degree of protection of ECG housing IP 20 1) Terminals and ECG construction are designed for an automatic wiring with robots 2) EOF I adjustable via zitares360 software 3) The protective earth connection is mandatory for safety and functionality of the system 2/8 01/2018 Errors reserved. 2/6
Temperatures (operation) Model Ambient (t a ) Case (t c ) CCD175-25FX... 25 C... +50 C max. + 75 C Lifetime Lifetime Operation at t c = t c,max 50,000 h; failure rate 10 % Operation at t c = t c,max - 10 K 100,000 h; failure rate 10 % Circuit breaker / Inrush current Model CCD175-25FX... typ. I peak /Δt 36A/ 102 μs Number of ECG at one singlepole circuit breaker (CB) CB-Type 10 A 16 A 20 A 25 A B 23 37 46 58 C 38 62 77 97 Typical current - time profile when switching on I[A] Ipeak - Data for U supply = 230 VAC, mains impedance = 1 Ω - In case of multi-polar CB the maximum number is reduced by 20 % - The max. number may differ depending on CB manufacturer. Please consider the specifications of the manufacturer. - Basically, CB with C-characteristics are recommended to be used in lighting groups. ½ x Ipeak t t 3/7 3/8
Operating data Model Input current 1) Input power 1) W Power factor 1) ECG Output current efficiency 1) (default) CCD175-25FX-20/... 0,14 29 0,98 87 100 750 (100) 17 55 2 25 1) All specifications with 230 VAC nominal operation and 100 % load 2) The output voltage range depends on the adjusted output current The max. value is limited to 55 VDC resp. to 25 W (max. power) divided to the current Output voltage / channel 2) A % ma V W Total output power Operating window 60 50 25 W 40 Output voltage [V] 30 20 10 0 0 100 200 300 400 500 600 700 800 900 Efficiency and power factor Output current [ma] Efficiency vs. output load Power factor vs. output load 100 1 0,95 Efficiency [%] 90 80 Power facor 0,9 0,85 0,8 0,75 70 750 ma 500 ma 200 ma 60 20 40 60 80 100 Total load at ECG output [%] 0,7 750 ma 0,65 500 ma 200 ma 0,6 20 40 60 80 100 Total load at ECG output [%] 4/8 01/2018 Errors reserved. 4/6
Wiring diagrams ECG input A Connection of ECG input side for LI control B Connection of ECG input side for control via push-button L N PE LI L N PE further ECG further ECG C Connection of BAG360-Interface for programming L N PE Software zitares360 USB BAG360 Interface Wiring diagram ECG output 1 Connection ECG output side LED + LED - Ωset Ωset R 5/7 5/8
Push-button operation / supplementary functions Push-button operation In addition to control via LI control signals, the LI interface can also be used for switching and dimming via a push-button. Button press Status: LEDs switched off, ECG in standby mode Status: LEDs switched on Short button press Long button press Switching on of LEDs to the last dimming level (memory function) Switching on of LEDs to the last dimming level and then dimming up or dimming down Switching off of LEDs and saving of current dimming level; ECG in standby mode Dimming up or dimming down of LEDs; each release and repressing of the button reverses the dimming direction Recovery function - behaviour after mains voltage interruption The behaviour of the ECG after mains voltage interruption can be specifi ed via the recovery function. Recovery function activated: After return of mains voltage the ECG returns to the operating mode before power interruption If the lighting system is switched on, the last set dimming level is called up. Recovery function deactivated: After return of mains voltage the ECG switches the lighting to 100 % luminous fl ux. (Factory setting) Activation or deactivation of the recovery function can also be implemented via the programming software zitares360. Synchronisation of the ECG If synchronising the ECG is needed in an application, this can be implemented via a push-button connected to the LI interface. When the lighting system is switched on the push-button must be pressed and held for approximately 10 s until the complete system is increased to 100 % luminous fl ux. All ECGs are then synchronised after releasing the push-button. 6/8 01/2018 Errors reserved.
Ωset interface The Ωset interface enables the connection of ohmic resistors for output current setting. The resistor value is evaluated by the ECG. According to a standardized formula the output current is set on a certain level depending on the resistance. Remarks: The Ωset interface is not galvanically isolated against mains voltage. The connected resistor has to be protected against short-circuit to earth. Therefore the use of resistors with basic insulation is mandatory. For the selection of the resistor type the specifi cation of the ECG terminals has to be additionally considered. Model Min. Rset Max. Rset Output current w/o Rset kω kω ma CCD175-25FX... 6,6 50 100 Calculation of the resistance value for the output current setting: I out [A] = 5 V Rset [Ω] 1000 Rset resistance [E24 / E48] Ω Output current A 49,900 0.100 33,200 0.151 24,900 0.201 20,000 0.250 16,500 0.303 14,300 0.350 12,400 0.403 11,000 0.455 10,000 0.500 9,090 0.550 8,250 0.606 7,680 0.651 7,150 0.699 6,650 0.752 7/7 7/8
Programming and software settings Programming of ECG is done via the LI interface by using the BAG360-Interface (Order no. 10133000) and the software zitares360 as of version 1.7. The connection of the ECG to the interface is shown in figure C in section Wiring diagams ECG input. The software and programming documentation contains further information. This is can be requested or is available via our website. Parameter Factory setting Comments DC detection deactivated 100 % luminous fl ux during DC operation Recovery function deactivated 100 % luminous fl ux after mains voltage interuption Output current minimum output current if no resistor is connected to the Ωset interface ECG dimensions Model X X M Y Z Z M mm mm mm mm mm CCD175-25FX... 280 270 30 21 9 Z M Y Z X M X Logistic data Model Order no. EAN Weight ECG ECG PU 1) Dimensions PU Weight PU kg pcs. mm kg CCD175-25FX-20/220-240/LI 10132980 404689034791 0,21 86 345 x 285 x 182 14 1) Packaging unit Conformance with regulations EN 61347-1 General and safety requirements EN 61347-2-13 Particular requirements for d.c. or a.c. supplied electronic control gear for LED modules IEC 61347-2-13/J Particular additional safety requirements for a.c., a.c./d.c. or d.c. supplied electronic control gear for emergency lighting EN 62384 D.C. or A.C. supplied electronic control gear for LED modules - Performance requirements EN 61547 Equipment for general lighting purposes - EMC immunity requirements EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 62386-101 Digital addressable lighting interface - General requirements - System EN 62386-102 Digital addressable lighting interface - General requirements for control gear EN 62386-207 Digital addressable lighting interface - Particular requirements for control gear - LED modules (device type 6) IEC 60068-2-6 Environmental testing: Tests Test Fc: Vibration (sinusoidal) IEC 60068-2-27 Environmental testing: Tests Test Ea and guidance: Shock BAG electronics GmbH Kleinbahnstrasse 27 59759 Arnsberg/Germany info@oem-systems.com Phone +49 2932 9000-9800 Fax +49 2932 9000-9796 07/2018 180731 8/8