Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Similar documents
Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Resistance thermometer Model TR31, miniature design

Field indicator for current loops with HART communication Models DIH50, DIH52

HART field temperature transmitter Models TIF50, TIF52, TIF62

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Field indicator for current loops with HART communication Models DIH50, DIH52

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Analogue Temperature Transmitter

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Indicator for panel mounting Model

Digital indicator for panel mounting With multi-function input Model DI25

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

OEM pressure transmitter For mobile working machines Model MH-3

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Flush pressure transmitter For viscous and solids-containing media Model S-11

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Submersible pressure sensor For oils and fuels Model LF-1

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Submersible pressure sensor For water and wastewater Model LW-1

Temperature transmitter itemp PCP DIN rail TMT 121

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Temperature Input Module for Zone 1 Series 9482/32

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Temperature Transmitter itemp RTD DIN rail TMT 127

High-precision process calibrator Model CED7000

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Level Measurement. Applications. Special features. Description

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Pressure transmitter for general industrial applications Model A-10

Electronic temperature switch with display Model TSD-30

Hand-held temperature calibrator Model CEP3000

OPTITEMP TT 10 C/R Technical Datasheet

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Pressure transmitter for general industrial applications Model A-10

High-quality pressure transmitter For general industrial applications Model S-10

Pressure transmitter For general industrial applications Model A-10

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

High-quality pressure transmitter For general industrial applications Model S-20

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Submersible pressure sensor For superior applications Model LF-1

Temperature transmitter itemp RTD DIN rail TMT 127

Certificate of Compliance

0 2 1 â Ó. itemp HART TMT182. Technical Information

Isolators A3/1.

Pressure transmitter For general industrial applications Model A-10

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Resistance Thermometers Model Series TR7X0, Sheathed Design

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Temperature head transmitter itemp TC TMT 188

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

OPTITEMP TT 20 Technical Datasheet

Digital Input Output Module for Zone 2 Series 9470/33

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

RMA42. Technical Information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Mechatronic pressure measurement. Applications. Special features. Description

Inductive sensor slot-type SI2-K08-AP7

In-Line Resistance Thermometers Model TR25

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolating Repeater Input Series 9163

02/11/2015

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Electrical Temperature Measurement

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

02/11/2015

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

MINI MCR-SL-UI-I-LP-NC

Isolators A3/1. Vibration Transducer Supply Unit Series

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Digital Input Output Module for Zone 2 Series 9470/33

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

SALES SERVICE +358 (0)

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Transcription:

Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building and plant construction Special features For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection For the connection of reed chains in a potentiometer circuit Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magwik Connection terminals also accessible from the outside Accuracy < 0.2 K / 0.1 % Fig. left: head mounting version, model T15.H Fig. right: rail mounting version, model T15.R Description These temperature transmitters are designed for universal use in plant and machine building, and also in the process industry. They offer high accuracy and excellent protection against electromagnetic influences (EMI). Via the WIKAsoft-TT configuration software and the model PU-448 programming unit, the model T15 temperature transmitters can be parameterised very easily, quickly and with a clear overview. The model T15 transmitter also has diverse supervisory functionality, such as the monitoring of the sensor wire resistance and sensor-break detection in accordance with NAMUR NE89 as well as monitoring of the measuring range. Moreover, these transmitters have comprehensive cyclic self-monitoring functionality. Besides the selection of the sensor type and the measuring range, the software enables the error signaling operation, damping and several measuring point descriptions to be stored. Furthermore, the WIKAsoft-TT software offers a line recording functionality where the temperature profile for the sensor connected to the T15 can be displayed. WIKA data sheet TE 15.01 10/2015 Page 1 of 10

Specifications Power supply Power supply U B Load R A Ex-relevant connection values DC 8 35 V R A (U B - 8 V) / 0.0215 A with R A in Ω and U B in V see Safety-relevant characteristics (explosion-protected version) Load diagram The permissible load depends on the loop supply voltage. Load RA in Ω 14141236.01 Min. voltage Operating voltage Ex instruments Non-Ex instruments Power supply U B in V Designation of connection terminals Input Resistance thermometer/ resistance sensor in 4-wire 3-wire 2-wire Potentiometer Output 4... 20 ma loop Connection programming unit PU-448 T15.H T15.R Page 2 of 10 WIKA data sheet TE 15.01 10/2015

Temperature transmitter input Sensor type Max. configurable measuring range (MR) Standard Minimum measuring span (MS) Resistance sensor Pt100 Pt1000-200... +850 C (-328... +1,562 F) -200... +850 C (-328... +1,562 F) IEC 60751:2008 IEC 60751:2008 10 K (50 F) or 3.8 Ω (greater value applies) Potentiometer 1) Reed chains 0... 100 % (= ^ min. 1... max. 50 kω) 10 % (= ^ min. 1 kω) Measuring current at the measurement Connection methods Max. lead resistance Max. 0.2 ma (Pt100/Pt1000) Max. 0.1 ma (Reed) 1 sensor in 2-, 3-, 4-wire connection (for further information, please refer to Designation of connection terminals ) 50 Ω each wire in 3- or 4-wire connection 1) R total: 10... 50 kω Basic configuration Sensor Pt100 Connection method 3-wire connection Measuring range 0... 150 C Error signalling Downscale Damping Off Analogue output, output limits, signalling Analogue output, configurable Linear to temperature per IEC 60751 Output limits per NAMUR NE43 Lower limit Upper limit 3.8 ma 20.5 ma Current value for signalling, configurable per NAMUR NE43 Downscale Upscale < 3.6 ma (3.5 ma) > 21.0 ma (21.5 ma) Time response Switch-on time (time to get the first measured value) Warm-up time Response time Damping Max. 3 s After max. 4 minutes the instrument will function to the specifications (accuracy) < 0.4 s Configurable between 1 s and 60 s Typical measuring rate Measured value update with 2- and 4-wire connection, approx. 20/s with 3-wire connection/potentiometer, approx. 5/s WIKA data sheet TE 15.01 10/2015 Page 3 of 10

Accuracy specifications 4... 20 ma Sensor Input (digital) CPU Output (analogue) Loop U i External sensor not included Accuracy input R digital I digital Accuracy output R sensor Overall instrument accuracy l loop The product-specific accuracy specifications refer to the overall instrument (Error overall = Error input + Error output ). To determine the overall error, all possible types of error must be considered. These are summarised in the following table. Special features Reference conditions Accuracy specifications Calibration temperature T ref = 23 C ±3 K Power supply U i_ref = 24 V Atmospheric pressure = 860... 1,060 hpa All accuracy specifications refer to the reference conditions. Measuring deviation per DIN EN 60770, NE145 2) Pt100, Pt1000 0.2 K or 0.1 % (greater value applies) MS < 200 K: 0.2 K MS > 200 K: 0.1 % of MS see chart Measuring deviation via span Potentiometer Relative accuracy: 0.2 % (R part /R overall in %) Absolute accuracy: 1 % (R part /R overall in Ω) Mean temperature coefficient (TC) every 1 K ambient temperature deviation from T ref ±0.01 % of the MS see chart Deviation of the current span via ambient temperature range Influence of power supply every 1 V voltage change from U i_ref Long-term drift in line with IEC 61298-2 per year ±0.005 % of the MS < 0.1 % of the MS ±0.01 % of the MS ±0.005 % of the MS < 0.1 % of the MS 2) In the event of interference caused by high-frequency electromagnetic fields in a frequency range from 200 to 400 MHz, an increased measuring deviation of up to 1.0 % is expected. Measuring deviation via span Deviation of the current span via ambient temperature range 1.2 0.12 Measuring deviation in K 1 0.8 0.6 0.4 0.2 Measuring deviation Deviation in ma 0.10 0.08 0.06 0.04 0.02 Deviation in ma 0 0 0 200 400 600 800 1000 1200-50 0 50 100 Span in K Ambient temperature (T ref = 23 C) Page 4 of 10 WIKA data sheet TE 15.01 10/2015

Monitoring Sensor break monitoring Sensor short-circuit Measuring range monitoring Drag pointer (internal temperature of the electronics) Configurable Standard: downscale Configurable Standard: downscale Monitoring of the set measuring range for upper/lower deviations configurable Standard: deactivated Comparative value in relation to the permissible ambient temperature Case T15.H head mounting version T15.R rail mounting version Material Plastic PBT, glass-fibre reinforced Plastic Weight 45 g 0.2 kg Ingress protection IP 00 Electronics completely potted Connection terminals, captive screws, wire cross-section Solid wire Wire with end splice Screwdriver 0.14... 2.5 mm² (AWG 24... 14) 0.14... 1.5 mm² (AWG 24... 16) Cross head (Pozidrive tip), size 2 (ISO 8764) Tightening torque 0.4 Nm 0.4 Nm IP 20 0.14... 2.5 mm² (AWG 24... 14) 0.14... 2.5 mm² (AWG 24... 14) Slotted, 3 x 0.5 mm (ISO 2380) Ambient conditions Permissible ambient temperature range {-50} -40... +85 {+105} C {-58} -40... +185 {+221} F Climate class per IEC 654-1:1993 Maximum permissible humidity Model T15.H per IEC 60068-2-38:2009 Model T15.R per IEC 60068-2-30:2005 Vibration resistance per IEC 60068-2-6:2008 Shock resistance per IEC 68-2-27:2009 Salt fog per IEC 68-2-52:1996, IEC 60068-2-52:1996 Condensation Free fall in line with IEC 60721-3-2:1997, DIN EN 60721-3-2:1998 Electromagnetic compatibility (EMC) per DIN EN 55011:2010, DIN EN 61326-2-3:2013, NAMUR NE21:2012, GL 2012 VI Part 7 Cx (-40... +85 C, 5... 95 % r. h.) Test max. temperature variation 65 C / -10 C, 93 % ±3 % r. h. Test max. temperature 55 C, 95 % r. h. Test Fc: 10... 2,000 Hz; 10 g, amplitude 0.75 mm Acceleration / shock width 30 g / 11 ms 100 g / 6 ms Severity level 1 Model T15.H: acceptable Model T15.R: acceptable in vertical mounting position Drop height 1.5 m Emission (group 1, class B) and interference immunity (industrial application) [HF field, HF cable, ESD, Burst, Surge] { } Items in curved brackets are options for an additional price, not for ATEX versions of the head mounting version and not for T15.R rail mounting version WIKA data sheet TE 15.01 10/2015 Page 5 of 10

Safety-relevant characteristics (explosion-protected version) Models T15.x-AI, T15.x-AC Intrinsically safe connection values for the current loop (4... 20 ma) Protection level Ex ia IIC/IIB/IIA, Ex ia IIIC or Ex ic IIC/IIB/IIA Parameters Models T15.x-AI, T15.x-AC Model T15.x-AI Gas hazardous application Dust hazardous application Terminals + / - + / - Voltage U i DC 30 V DC 30 V Current l i 130 ma 130 ma Power P i 800 mw 750/650/550 mw Effective internal capacitance C i 18.4 nf 18.4 nf Effective internal inductance L i 3.91 µh 3.91 µh Sensor circuit Parameters Model T15.x-AI Model T15.x-AC Ex ia IIC/IIB//IIA Ex ic IIC/IIB//IIA Ex ia IIIC Terminals 1-4 1-4 Voltage U o DC 30 V DC 30 V Strength of current I o 6.1 ma 6.1 ma Power P o 46 mw 46 mw Characteristics Linear Due to distance requirements of the applied standards, the IS power and signal circuit and the IS sensor circuit shall be considered as being galvanically connected to each other. The intrinsically safe supply and signal circuit and the intrinsically safe sensor circuit must be considered as galvanically connected to each other (with regard to explosion protection). Ambient temperature range Application Ambient temperature range Temperature class Power P i Group II -40 C T a +85 C T4 800 mw -40 C T a +70 C T5 800 mw -40 C T a +55 C T6 800 mw Group IIIC -40 C T a +40 C N / A 750 mw -40 C T a +75 C N / A 650 mw -40 C T a +100 C N / A 550 mw N / A = not applicable Comments: U o : Maximum voltage of any conductor against the other three conductors I o : Maximum output current for the least favourable connection of the internal current limiting resistors P o : U o x I o divided by 4 (linear characteristic) Page 6 of 10 WIKA data sheet TE 15.01 10/2015

Model T15.x-AN Power and signal circuit (4... 20 ma loop) Protection level Ex na IIC/IIB/IIA Parameters Model T15.x-AN Gas hazardous application Terminals + / - Voltage U i DC 35 V Current I i 21.5 ma Sensor circuit Protection level Ex na IIC/IIB/IIA Parameters Model T15.x-AN Terminals 1-4 Power P o 3.3 V x 0.1 ma 0.33 mw DC 3.3 V (maximum voltage limited at V9) 0.1 ma (maximum current limited at D10) Ambient temperature range Application Ambient temperature range Temperature class Group II -40 C T a +85 C T4-40 C T a +70 C T5-40 C T a +55 C T6 N / A = not applicable WIKA data sheet TE 15.01 10/2015 Page 7 of 10

Dimensions in mm Head mounting version, model T15.H Rail mounting version, model T15.R 99 17.5 7 22.5 22.5 33 44 113.6 99 17.5 2:1 The dimensions of the head-mounted transmitter match the form B DIN connection heads with extended mounting space, e.g. WIKA model BSS. The transmitters in rail mounting cases are suitable for all standard rails in accordance with IEC 60715. 113.6 Connecting PU-448 programming unit Head mounting version, model T15.H 2:1 Rail mounting version, model T15.R Attention: For direct communication via the serial interface of a PC/notebook, a model PU-448 programming unit is needed (see Accessories ). Page 8 of 10 WIKA data sheet TE 15.01 10/2015

Configuration software WIKAsoft-TT Accessories WIKA configuration software: free download from www.wika.com Model Version Order number Programming unit Simple operation 11606304 Model PU-448 LED status/diagnostic displays Compact design No further voltage supply is needed for either the programming unit or for the transmitter Magnetic quick connector magwik Replacement for crocodile clips and HART terminals Fast, safe and tight electrical connection For all configuration and calibration processes 14026893 WIKA data sheet TE 15.01 10/2015 Page 9 of 10

Approvals (option) Logo Description Country EC declaration of conformity EMC directive 2004/108/EC EN 61326 emission (group 1, class B) and interference immunity (industrial application) ATEX directive 94/9/EC European Community IECEx Hazardous areas IECEx member states Certificates (option) 2.2 test report 3.1 inspection certificate Approvals and certificates, see website Ordering information Model / Explosion protection / Additional approvals / Permissible ambient temperature / Configuration / Certificates / Options 2015 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 10 of 10 WIKA data sheet TE 15.01 10/2015 10/2015 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de