Engineering and Technical Teaching Equipment Motor-Generator Group AEL-EGMG24 Electrical Machines EMT7C EMT6B INTRODUCTION Synchronous machines can use permanent magnets to provide the magnetic field and since no power is used in providing the field this means that the machines are simpler and more efficient. However, the drawback is that there is no simple way to control such machines. Permanent magnet synchronous generators (PMSGs) are typically used in gensets and applications such as wind turbines. ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) 1 Certificates ISO 14001 and ECO- Management and Audit Scheme (environmental management) Certificate and Worlddidac Member
GENERAL DESCRIPTION The AEL-EGMG24 Motor-Generator Group has been designed by Edibon in order to study the behavior of permanent magnet alternator with main motor control. Thanks to this trainer, the student will be able to train the permanent magnet synchronous generator, wire the generator-motor group, analyze the power factor, observe the relationship between speed and voltage, study the behavior without load and check the drop voltage when the user connects resistive, inductive and capacitive loads. The AEL-EGMG24 includes the following modules: N-ALI02. Main Power Supply. N-VVCA/M. AC Motor Speed Controller (intermediate option). EMT7C. Asynchronous Three-Phase Motor of Squirrel Cage (8 poles). EMT6B. Permanent Magnets Synchronous Three-Phase Generator (24VAC). N-TRA30. Three-Phase Isolating Transformer 24VAC/380VAC. N-REFT300. 300 Ohms Three-Phase Fixed Resistor Module. (2 units) N-INDT. Three-Phase Variable Inductive Load with commutator. N-CONT. Three-Phase Variable Capacitor Load with commutator. N-EAL. Network Analyzer Unit. Optional learning software: In addition, Edibon provides optional software (AEL-EGMG24/ICAI) to reinforce knowledge about this field. This software is formed by: ECM-SOF. EDIBON Classroom Manager (Instructor Software). ESL-SOF. EDIBON Student Labsoft (Student Software). The application AEL-EGMG24 can be mounted on rack (option A) or on rail (option B): Option A: This application needs the following racks. N-RACK-M (2 units). Optionally the AEL-WBR. Electrical Workbench (Rack) can be supplied to place the rack/s. Option B: This application can be mounted on rail. Optionally the AEL-WBC. Electrical Workbench (Rail) can be supplied to mount the modules. 2
Specifications The trainer includes the following modules: N-ALI02. Domestic Main Power Supply Supply voltage (Single-Phase): 230 VAC, PH+N+G. ON-OFF removable key. Output Voltage Connections: Two Single-Phase: 230 VAC. N-ALI02 Single-Phase supply hose connecting plug. Differential magnetothermal, 2 poles, 25A, 30mA AC 6KA. N-VVCA/M. AC Motors Speed Controller (intermediate option) Supply voltage: 230 VAC. Nominal power: 0,4 kw. PWM output voltage connections: Three-Phases: 230 VAC. N-VVCA/M 10K, potentiometer for the induction motor control speed. Setting and visualization display of the machine parameters. EMT7c. Asynchronous three-phase motor of squirrel cage (8 poles) Nominal Power: 550 W. Nominal Voltage: 3x230 / 400 VAC. Frequency: 50/60 Hz. Number of poles: 8. EMT7C RPM: 750 r.p.m Nominal Current: 3,6 / 2 A. EMT6b. Permanent magnets synchronous three-phase generator (24 Vac) Three-Phase synchronous generator with permanent magnets. Nominal Power: 0.6 kva. Synchronous speed: 850 r.p.m. Number of poles: 8. EMT6B N-TRA30. 1 KVA Three-Phase Isolating Transformer 24VAC/400VAC Nominal Power: 1kVA. Input Voltage: Three-Phase 24 VAC. Output Voltage: Three-Phase 400 VAC. N-TRA30 3
Specifications N-REFT300. 300 Ohms Three-Phase Fixed Resistor Module (2 units) Nominal voltage: 400 VAC. Resistor value: 3x300 Ohms. Nominal power: 3x200 W. Manual commutator to switch on/off the resistors. N-REFT300 Fuses: 3x5 A. Terminals: Three input terminals (3PH). Three output terminals (3PH). Ground terminal. N-INDT. Three-phase Commutable Inductive Load Nominal voltage: 400 VAC. Inductance value: 1,4H. Nominal current: 1,6 A. Manual commutator to switch on/off the inductances. N-INDT Fuses: 3x2 A. Terminals: Four inputs terminals (3PH+N). Four outputs terminals (3PH+N). Ground terminal. N-CONT. Three- phase Commutable Capacitive Load Capacitor value: 3x7 uf. Nominal Voltage: 400 VAC. Manual commutator to switch on/off the capacitors. Fuses: 3x4 A. N-CONT Terminals: Four inputs terminals (3PH+N). Four outputs terminals (3PH+N). Ground terminal. 4
Specifications N-EAL. Network Analyzer Unit ON-OFF switch. Supply voltage: 230 VAC. Input terminals: Input connection with the measurement point. Output terminals: Output connection with the measurement point. N-EAL Digital outputs: Three digital outputs are used for pulses or alarms, or for combining both. Fuses: 3x10 A. Network Analyzer Display. It shows: Active, reactive and apparent power. Active, reactive and apparent energies. Lines and phase currents. Line and phase voltages. Frequencies. Power Factor. All necessary cables to realize the practical exercises are included. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. 5
Exercises and Practical Possibilities 1.- Wiring of the motor-generator group. 2.- Commissioning of the Frequency Controller. 3.- Adjusting the necessary values in the frequency controller. 4.- Adjusting the rotation direction. 5.- Adjusting the start function. 6.- Frequency/speed control of permanent magnet synchronous generator. 7.- Study of voltage control generation. 8.- Study of electrical generator with no load. 9.- Study of drop voltage with resistive load. 10.- Study of drop voltage with inductive load. 11.- Study of drop voltage with capacitive load. 12.- Study of power factor. 13.- Study of electrical generator with different power factors. 14.- Study of the voltage versus speed of the permanent magnet synchronous generator. REQUIRED SERVICES - Electrical supply: single phase, 220 V./50 Hz. or 110 V./60 Hz. DIMENSIONS AND WEIGHTS AEL-EGMG24: -Dimensions: 1380 x 840 x 2010 mm. approx. (54.33 x 33.07 x 79.13 inches approx.) -Weight: 80 Kg. approx. (176 pounds approx.) 6
Optional AEL-EGMG24/ICAI. Interactive Computer Aided Instruction Software System: With no physical connection between unit and computer (PC), this complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL- SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. Instructor Software -ECM-SOF. EDIBON Classroom Manager (Instructor Software). ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. ECM-SOF. EDIBON Classroom Manager (Instructor Software) Application Main Screen Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. ECAL. EDIBON Calculations Program Package - Formula Editor Screen ETTE. EDIBON Training Test & Exam Program Package - Main Screen with Numeric Result Question ERS. EDIBON Results & Statistics Program Package - Student Scores Histogram 7
Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Optional Student Software -ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. ESL-SOF. EDIBON Student LabSoft (Student Software) Application Main Screen Test self-correction. Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. For more information see ICAI catalogue. Click on the following link: /en/files/expansion/icai/catalog EPE. EDIBON Practical Exercise Program Package Main Screen ECAL. EDIBON Calculations Program Package Main Screen ERS. EDIBON Results & Statistics Program Package - Question Explanation * Specifications subject to change without previous notice, due to the convenience of improvement of the product. REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). ESPAÑA - SPAIN. Tel: 34-91-6199363 Fax: 34-91-6198647 E-mail: edibon@edibon.com Web: Edition: Date: April/2017 8