DAI. Connecting Analog and Frequency Fuel Level Sensors

Similar documents
User s manual. Signaling. Connection of emergency button

Installation and connection of Galileosky v4.0 tracking devices

Remote Sensor Manual. User Guide. Revision A.0

Technical description of the fuel tank sensor "Escort TD-500"

CONTACTLESS READER OPERATION MANUAL. Ver. 1.1

Galileosky GLONASS/GPS Satellite v4.0 (0229) User s manual. Galileosky terminals GLONASS/GPS Satellite v4.0 User s manual.

ULM-0.8/2.5 Ultrasonic Fuel Level Meter

ENAiKOON inmarsat-600

Omnicomm Terminals Profi 2.0 Profi 2.0 WiFi Optim 2.0 Light 2.0

Terminals Galileo GLONASS v4.x User s manual

Underwater GPS User Manual

Advanced Soldier Monitoring and Tracking System Using GPS and GSM Introduction

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

(51) Int Cl.: G09B 29/00 ( ) G01C 21/00 ( ) G06T 1/00 ( ) G08G 1/005 ( ) G09B 29/10 ( ) H04Q 7/34 (2006.

Castle Creations, INC.

TRBOnet Mobile. User Guide. for ios. Version 1.8. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

The Role and Design of Communications for Automated Driving

Industrial Systems Design & Implementation

ZONESCAN net Version 1.4.0

TECHNICAL DATASHEET #TDAX021901

Specifications for: OSOP Sixaola4-V4

BSc (Hons) Computer Science with Network Security, BEng (Hons) Electronic Engineering. Cohorts: BCNS/17A/FT & BEE/16B/FT

TRBOnet Enterprise. Quick Reference Guide. Version 5.2. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

Chapter 3 Data and Signals

Experiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor)

ACCIDENT DETECTION AND MESSAGING SYSTEM USING GPS AND GSM TECHNIQUES

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

Version 9.1 SmartPTT Monitoring

Data Concept Analog and Digital Signal Periodic and Non-Periodic Signal Sine Wave Wave length Time and Frequency Domain Composite Signal Bandwidth

EVO4 Data Logger USER GUIDE

Accident prevention and detection using internet of Things (IOT)

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

A Master Inventor at work

MICROWAVE MOISTURE SENSOR WITH WIRELESS DATA TRANSMISSION FL-WAPP

Ohm s Law. Equipment. Setup

Increasing Broadcast Reliability for Vehicular Ad Hoc Networks. Nathan Balon and Jinhua Guo University of Michigan - Dearborn

GMI 10. quick start manual

Aztec Micro-grid Power System

Momo Software Context Aware User Interface Application USER MANUAL. Burak Kerim AKKUŞ Ender BULUT Hüseyin Can DOĞAN

Monitoring Temperature using LM35 and Arduino UNO

TRBOnet Guard Tour Configuration and Operation Guide

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Ahmad Faraz Hussain 1, Polash Kumar Das *1, Prabhat Ranjan 1 1 School of Electronic and information, South China University of Technology Guangzhou,

TRBOnet Enterprise/PLUS

A novel, broadcasting-based algorithm for vehicle speed estimation in Intelligent Transportation Systems using ad-hoc networks

LRC Circuit PHYS 296 Your name Lab section

Product Information Using the SENT Communications Output Protocol with A1341 and A1343 Devices

DUAL 4-20 MA NETWORK BRIDGE. Voltage. Regulator. Neuron CPU. Ohm Sense Resistor. Model 1400A Block

ME scope Application Note 01 The FFT, Leakage, and Windowing

Crawler Tractors PR 714 PR 764. Product information. Grade control systems

Bloodhound RMS Product Overview

DESCRIPTION DIMENSIONS HOW TO ORDER

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

Chapter 4. Communication System Design and Parameters

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

ZONESCAN net Version 1.4.1

Smart eye using Ultrasonic sensor in Electrical vehicles for Differently Able.

JSC Progress MRI. ACTIVITY AREAS, EXPERIENCE and SUGGESTIONS

CONTENTS INTRODUCTION ACTIVATING VCA LICENSE CONFIGURATION...

SP310001/02: Wireless Power Controller for Fast Charging Transmitter

Activity Electrical Circuits Simulation

I.G.C.S.E. Ratio & Proportion. You can access the solutions from the end of each question

How to do Geo-fencing with the FM200

Brushless Servo Motor Drives xdrive Series

Function Generator MODEL FG-500 Instruction Manual ELENCO

>>> RALLY SAFETY SYSTEM

Reactance and Impedance

More Fun with A/D Converters

GENERAL OPERATING INFORMATION

SSI Technologies - Application Note AT-AN1 Acu-Trac Ultrasonic Fluid Level Sensors Product Overview

Technical Bulletin April Opticom GPS System Verifying GPS coverage in a Fire Station

DESCRIPTION MODEL 1450 NOTE

FlatPack Ultrasonic Sensors

Applying Multisensor Information Fusion Technology to Develop an UAV Aircraft with Collision Avoidance Model

Influence of Vibration of Tail Platform of Hydropower Station on Transformer Performance

Above All. The most sophisticated unit for tracking containers in real time for security and management.

B.E SEMESTER: 4 INFORMATION TECHNOLOGY

WPE 48N USER MANUAL Version1.1

Uni-Mux XQL Multi-Channel Data Acquisition Module

Application Information

Area Traffic Control System (ATCS)

ANEMOMETER VECTOR A100L2 & VECTOR A100LK & VECTOR A100LM

Part I: Introduction to Wireless Sensor Networks. Alessio Di

Programming PIC Microchips

IEFIS GPS manual Applicable to iefis G3 including Lite versions Firmware or later

VBRC 5. Radio Communicator. Installer Manual

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

Nebraska 4-H Robotics and GPS/GIS and SPIRIT Robotics Projects

era, eric, era-lora, eric-lora & eric-sigfox Evaluation Board with GNSS

Your Network. Optimized.

Power Supply Rejection Ratio Measurement

Voltage Current and Resistance II

CS307 Data Communication

Simple Electrical Circuits

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

MODERN DIAGNOSTIC EQUIPMENTS IN ENERGETIC MEASUREMENT

SLX-1 Multi-Application GNSS Receiver

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Glossary of terms. Short explanation

The GPS Classroom. Jared Covili

Transcription:

DAI. Connecting Analog and Frequency Fuel Level Sensors User Manual www.galileosky.com

Contents Necessary Tools, Devices, Materials... 3 General Information... 4 Fuel Level Sensor Connection... 5 Connection and Setting of Analog Fuel Level Sensor... 6 Connection and Setting of Frequency Fuel Level Sensors... 7 Setting the Tracking Device for operation with Monitoring Software... 9 Setting the Monitoring Software for Cooperation with FLS... 10 2

Necessary Tools, Devices, Materials To connect Galileosky tracking device (hereinafter tracking device, device) you should have: 1. Electrical tools. 2. Set of connecting wires with fuses. 3. Windows-based computer with the installed program of configuration of Galileosky tracking devices "Configurator". It is recommended to install the latest version of the program from the site https://galileosky.com/podderzhka/programmyi.html 3

General Information Galileosky devices can read in frequency signal and process it in accordance with customized algorithm. As signal sources analog and frequency fuel level sensors (hereinafter frequency FLS) of different manufacturers can be used (Pic. 1) Pic. 1 Fuel level sensors Principle of work of an analog FLS is based on converting measured electric capacity into voltage, depending on the fuel level in the tank. Voltage value on the sensor output depends on the FLS model and, as a rule, the range is from 0 to 20 V, but not higher than connection voltage of the sensor. Principle of work of a frequency FLS is based on converting measured electric capacity into frequency signal in proportion to fuel level in a tank. Signal frequency depends on the FLS model and is usually from 100 to 4000 Hz; signal amplitude also depends on the FLS model, but is not higher than connection voltage of the sensor (Pic. 2). Pic. 2 Frequency signal 4

Fuel Level Sensor Connection Install a fuel level sensor into a tank of a vehicle according to manufacturing factory recommendations (Pic. 3). Pic. 3 Installation of a FLS into a tank 5

Connection and Setting of Analog Fuel Level Sensor Connecting of an analog fuel level sensor to a Galileosky device should be done in accordance with the scheme, presented in Picture 4 of this manual. Analog output of a FLS is to be connected to one of the discrete analog inputs (hereinafter - DAI) of the device. Negative input of the FLS should be connected to the negative side of power supply of a Galileosky tracking device. Pic. 4 Analog FLS connecting scheme To set Galileosky tracking device for operating with analog FLS it is necessary to perform the following: - Connect to the device via Configurator service program, go to tab Settings -> Ins/Outs. For the input that is engaged with the FLS set the filter type Mean value and filter length 5, then click Apply button (Pic. 5) Pic. 5 Input setting - Start the car, go to tab Device of the Configurator and make sure the signal from FLS is transmitted to Galileosky device. (Pic. 6) After it, you need to perform calibration of FLS in accordance with the manufacturer s recommendations. Pic. 6 Checking the analog signal from FLS 6

Connection and Setting of Frequency Fuel Level Sensors Connecting of a frequency fuel level sensor to a Galileosky device should be done in accordance with the scheme, presented in Picture 7 of this manual. Frequency output of a FLS is to be connected to one of the discrete analog inputs (hereinafter - DAI) of the device. Negative input of the FLS should be connected to the negative side of power supply of a Galileosky tracking device. In case if a manufacturer of FLS has not provided shifting of a frequency signal to + power, 10kOhm resistor R1 must be connected additionally. Pic. 7 Frequency FLS connecting scheme To set Galileosky tracking device for working with frequency FLS it is necessary to connect the device to Configurator service program and go to tab Settings -> Ins/Outs. Setting the discrete analog inputs is carried out in two stages: 1. Stage 1. To measure the average amplitude of a frequency signal: Select the filter type middle value ; Set the filter length as 50 ; Run the engine; Go to the Device tab and slightly increasing the engine speed for 1 minute detect the mean value of the signal amplitude, that comes to the custom input (Pic. 8). Pic. 8 Measurement of mean amplitude of frequency signal 7

If the manufacturer has indicated frequency signal amplitude in the documentation the target value is equal to half of that amplitude. 2. Stage 2. Filter settings to operate with frequency FLS: Go to tab Ins/Outs tab and set filter type frequency counting ; Set the filter length as 1 ; Set discrete signal limit to the average amplitude value measured at the first stage (Pic. 9); Go to the Settings tab > Protocol and in the main packet settings tick the DAI fields to which frequency fuel level sensors are connected (Pic. 7); Click Apply button; Run the engine and perform calibration of FLS in accordance with manufacturing factory recommendations. Pic. 9 Setting DAI on frequency count 8

Setting the Tracking Device for operation with Monitoring Software Go to tab Settings -> Protocol and for the Main packet tick those discrete analog inputs, where analog or frequency FLS is connected (Pic. 10). Pic. 10 Main packet setting 9

Setting the Monitoring Software for Cooperation with FLS After analog input of Galileosky tracking device has been configured monitoring software should be configured (hereinafter Monitoring software). It should be done in accordance with software manufacturer recommendations. As a rule, it is necessary to create a sensor in the monitoring software and fill in the calibration table for its values: Measured FLS values are transmitted by Galileosky tracking device to the server as absolute values which the tracking device has registered; On monitoring server mathematical computation of fuel level in accordance with calibration table values and calculation formula is performed; Graphical user table reports on fuel level and fuel consumption are based on the calculated values (Pic. 11, 12). Pic. 12 Example of table report on the fuel level Pic. 11 Example of graphical report on the fuel level The connection of analog and frequency fuel level sensor to Galileosky tracking device is completed. The tracking device is ready to operate. RSA Galileosky, LLC produces satellite monitoring equipment for GPS and GLONASS real time vehicles monitoring. The tracking devices determine the mobile object location recording the time and route as points with geographical coordinates and send the data to the server to be further processed and sent to the traffic controller panel. 10

In addition, a number of other vehicle parameters are recorded: the state of analog and discrete inputs of the tracking device and the state of digital interfaces. The tracking devices can be used in any vehicle. 11