Rosemount 848T Eight Input Temperature Transmitter with FOUNDATION Fieldbus

Similar documents
Rosemount 148 Temperature Transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

The Rosemount 848T Wireless Temperature Transmitter

Rosemount 248 Temperature Transmitter

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Rosemount 248 Temperature Transmitter

Rosemount 644 Temperature Transmitter

Alphaline Temperature Transmitters

Rosemount 644 Temperature Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 248 Wireless Temperature Transmitter

Rosemount 333 HART Tri-Loop

Rosemount 248 Temperature Transmitter and Monitoring Assembly

Rosemount 248 Wireless Temperature Transmitter

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Rosemount 5400 Series Radar Level Transmitter

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount 648 Wireless Temperature Transmitter

Head mounted Temperature Transmitter TF02/TF02-Ex

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Rosemount 702 Discrete Input Transmitter

Rosemount 644 Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter

ATT2100/2200 SMART TEMPERATURE TRANSMITTER. Application Areas: ATT 2200 ATT2100

Two-Wire Programmable Transmitter for:

Temperature transmitter itemp PCP DIN rail TMT 121

SMART TEMPERATURE TRANSMITTERS. smar

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Rosemount 648 Wireless Temperature Transmitter

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - Head Mounted

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Fisher 4200 Series Electronic Position Transmitters

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

Temperature Input Module for Zone 1 Series 9482/32

itemp HART DIN rail TMT112

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Model 264IB. ABB 2600T Series Engineered solutions for all applications

0 2 1 â Ó. itemp HART TMT182. Technical Information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

ThermoPLUS Smart Temperature Transmitter

SITRANS T measuring instruments for temperature

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Temperature transmitter with local display RIT 261

General Specifications

IP26 Series Current to Pneumatic Converter

Rosemount 248 Wireless Temperature Transmitter

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Rosemount 3101, 3102, and 3105

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

STT 3000 Smart Temperature Transmitter

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Process Protection Acoustic sensors for pump monitoring

Rosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Fisher 646 Electro-Pneumatic Transducers

General Specifications

0 2 1 â Ó. itemp HART TMT182. Technical Information

General Specifications

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Temperature head transmitter itemp TC TMT 188

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

OPTITEMP TT 20 Technical Datasheet

Universal Intelligent 2-wire DIN Rail Transmitters

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

itemp PA TMT184 Technical information

Fisher 646 Electro Pneumatic Transducer

HART field temperature transmitter Models TIF50, TIF52, TIF62

Isolators A3/1. Vibration Transducer Supply Unit Series

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Universal Intelligent 2-wire In-head Transmitters

Mass and Volume Flow Transmitter

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Rosemount 5408 and 5408:SIS Level Transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

0013-0100-697, Rev F Provides significant installation and operation savings for temperature monitoring applications ccepts eight independently configurable RTD, thermocouple, ohm, and millivolt inputs Mounts anywhere field hardened, intrinsically safe, and low power Provides diagnostic and calculation capabilities Interface the Rosemount T to existing systems using the Rosemount 320 Fieldbus Interface Module Rosemount T Rosemount T Eight Input Temperature Transmitter with FOUNDTION Fieldbus Contents The First Choice in Temperature Monitoring..................................... page 2 Specifications............................................................ page 3 Product Certifications...................................................... page Dimensional Drawings..................................................... page 11 Ordering Information...................................................... page 1 www.rosemount.com

Rosemount T Product Data Sheet 0013-0100-697, Rev F The First Choice in Temperature Monitoring The Rosemount T Eight Input Temperature Transmitter will simplify and reduce the cost of a plant s process control architecture. Traditional temperature monitoring methods (wire direct, low cost single input transmitters, and multiplexers) will be eliminated with the introduction of this intrinsically safe, eight input transmitter that mounts beside the process. The use of FOUNDTION fieldbus enables this quantum leap in temperature monitoring. Combined with the Rosemount 320 Fieldbus Interface Module, Rosemount T measurements can be interfaced to existing systems. LOWEST COST SOLUTION The Rosemount T offers the lowest cost solution for temperature monitoring measurements. (e.g. distillation columns, tanks, reactors, boilers, etc.). This transmitter can reduce installed costs by as much as 70% per point when compared to traditional sensor wire direct applications. REDUCES I.S. BRRIER COSTS For intrinsically safe installations, only one barrier is needed to safely power several Rosemount T transmitters. s a result, one barrier can support at least 2 temperature measurement points resulting in significant savings. The new FISCO (Fieldbus Intrinsically Safe Concept) certification on the Rosemount T allows even more measurements per I.S. segment. EIGHT INDEPENDENT SENSOR INPUTS The Rosemount T accepts eight independently configurable sensor inputs (2- and 3-wire RTDs, thermocouples, mv, and ohm). MOUNTS VIRTULLY NYWHERE The Rosemount T s ambient temperature limits, RFI immunity compliance, intrinsic safety approvals, and ability to mount in industrial environments provides optimum mounting flexibility. DIGNOSTICS ND MI FUNCTION BLOCKS FOUNDTION fieldbus offers inherent diagnostics that provide continuous measurement status (good, bad, or uncertain) as well as sensor failure indication. lso, the Rosemount T offers the Multiple nalog Input (MI) function block. The MI block allows all eight sensor inputs to be communicated with one function block, resulting in greater network efficiency. CONVERTS NLOG TO FIELDBUS The Rosemount T can accept 20 m inputs and output the value onto FOUNDTION fieldbus. The optional analog connector allows quick connection of the Field Communicator for local configuration. The Rosemount T Transmitters power PlantWeb providing multi-input devices with calculating capability using Input Selector function blocks Rosemount Temperature Solutions Rosemount 6 Temperature Transmitter Head mount styles available with HRT or FOUNDTION fieldbus protocol. Rail mount style available for HRT protocol. Rosemount T Eight Input Temperature Transmitter Eight input transmitter available with FOUNDTION fieldbus protocol. Rosemount 320 Fieldbus Interface Module Provides an interface between FOUNDTION fieldbus instruments and systems without fieldbus capability using standard interface protocols. Rosemount 2 Temperature Transmitter Head mount (DIN B) and Rail mount style with HRT protocol and complete temperature assembly. Rosemount 31P Temperature Transmitter Two-compartment housing, dual sensor design available with HRT or Foundation fieldbus protocol. Rosemount 1 Temperature Transmitter Head mount style (DIN B) PC-configurable transmitter. Rosemount sensors, thermowells, and extensions Rosemount has a broad offering of RTD and thermocouples that are designed to meet plant requirements. 2

0013-0100-697, Rev F Rosemount T Specifications FUNCTIONL Inputs Eight independently configurable channels including combinations of 2- and 3-wire RTDs, thermocouples, mv, and Ω inputs. -20 m inputs using optional connector(s). ll sensor terminals are rated to 2. VDC. Outputs Manchester-encoded digital signal that conforms to IEC 115-2 and IS 50.02. Status If self-diagnostics detect a sensor burnout or a transmitter failure, the status of the measurement will be updated accordingly. mbient Temperature Limits 0 to 15 F ( 0 to 5 C) Isolation Input/output isolation is tested to 500 VC rms (707 VDC). Input/input isolation between each sensor input connector is tested to 500 VC rms (707 VDC). Input/input isolation between sensors on the same input connector is 3 VC at 50 60 Hz, 1.5 VDC. Power Supply Powered over FOUNDTION fieldbus with standard fieldbus power supplies. The transmitter operates between 9.0 and 32.0 V dc, 22 m maximum. (Transmitter power terminals are rated to 2. V dc.) Transient Protection The transient protector (option code T1) helps to prevent damage to the transmitter from transients induced on the loop wiring by lightening, welding, heavy electrical equipment, or switch gears. This option is installed at the factory for the Rosemount T and is not intended for field installation. SME B 16.5 (NSI)/IEEE C62.1-1991 (IEEE 57), Location Categories 2, B3. 6 kv / 3 k peak (1.2 x 50 µs Wave x 20 µs Combination Wave) 6 kv / 0.5 k peak (100 khz Ring Wave) kv peak EFT (5 x 50 ns Electrical Fast Transient) Update Time pproximately 1.5 seconds to read all eight inputs. Humidity Limits 0 100% non-condensing relative humidity Turn-on Time Performance within specifications is achieved in less than 50 seconds after power is applied to the transmitter. Backup Link ctive Scheduler (LS) The transmitter is classified as a device link master, which means it can function as a Link ctive Scheduler (LS) if the current link master device fails or is removed from the segment. The host or other configuration tool is used to download the schedule for the application to the link master device. In the absence of a primary link master, the transmitter will claim the LS and provide permanent control for the H1 segment. FOUNDTION Fieldbus Parameters Schedule Entries 25 Links 30 Virtual Communications Relationships (VCR) 20 PHYSICL Mounting The Rosemount T can be mounted directly onto a DIN rail or it can be ordered with an optional junction box. When using the optional junction box, the transmitter can be mounted onto a panel or to a 2-in. pipe stand (with option code B6). Entries for Optional Junction Box No entry Used for custom fittings Cable Gland 9 x M20 nickel-plated brass glands for 7.5 11.9 mm unarmored cable Conduit 5 plugged 0.6-in. diameter holes suitable for installing 1 /2-in. NPT fittings. Materials of Construction for Optional Junction Box Junction Box Type Paint luminum Epoxy Resin Plastic N Stainless Steel N Weight ssembly Weight oz lb kg Rosemount T only 9.60 0.60 0.27 luminum (1) 7.2.9 2.22 Plastic (1) 5.1 3.6 1.65 Stainless Steel (1) 77.0.1 2.1 (1) dd 35.2 oz (2.2 lb, 0.99 kg) for nickel-plated brass glands Environmental Ratings NEM X, CS Enclosure Type X, and IP66 with optional junction box. larms The I and ISEL function blocks allow the user to configure the alarms to HI-HI, HI, LO, or LO-LO with a variety of priority levels and hysteresis settings. 3

Rosemount T Product Data Sheet 0013-0100-697, Rev F FUNCTION BLOCKS nalog Input (I) Processes the measurement and makes it available on the fieldbus segment. llows filtering, alarming, and engineering unit changes. Input Selector (ISEL) Used to select between inputs and generate an output using specific selection strategies such as minimum, maximum, midpoint, or average temperature. Since the temperature value always contains the measurement status, this block allows the selection to be restricted to the first good measurement. Multiple nalog Input Block (MI) The MI block allows the eight I blocks to be multiplexed together so they serve as one function block on the H1 segment, resulting in greater network efficiency. Susceptibility ESD Radiated Burst Surge Conducted Magnetic kv contact discharge kv air discharge 0 1000 MHz at 10 V/m M 1 kv 1 kv line to-ground 150 khz to 0 MHz at 3V 50 Hz at 30 /m PERFORMNCE The transmitter maintains a specification conformance of at least ±3. Stability ±0.1% of reading or 0.1 C (0.1 F), whichever is greater, for 2 years for RTDs. ±0.1% of reading or 0.1 C (0.1 F), whichever is greater, for 1 year for thermocouples. Self Calibration The transmitter s analog-to-digital circuitry automatically self-calibrates for each temperature update by comparing the dynamic measurement to extremely stable and accurate internal reference elements. Vibration Effect Transmitters are tested to the following vibration conditions with no effect on performance: Frequency cceleration 10-60 Hz 0.21 mm peak displacement 60-2000 Hz 3 g CE Electromagnetic Compatibility Compliance Testing Meets the criteria under IEC 61326 mendment 1, 2000: Emissions 30 230 MHz, 30 db (uv/m) at 10 m 230 1000 MHz, 37 db (uv/m) at 10 m

0013-0100-697, Rev F Rosemount T CCURCY TBLE 1. Input Options/ccuracy Input Ranges ccuracy Over Range(s) Sensor Option Sensor Reference C F C F 2- and 3-Wire RTDs Pt 100 ( = 0.0035) IEC 751; = 0.0035, 1995 200 to 50 32 to 1562 ± 0.30 ± 0.5 Pt 100 ( = 0.003916) JIS 160, 191 200 to 65 32 to 1193 ± 0.30 ± 0.5 Pt 200 IEC 751; = 0.0035, 1995 200 to 50 32 to 1562 ± 0.5 ± 0.9 Pt 500 IEC 751; = 0.0035, 1995 200 to 50 32 to 1562 ± 0.3 ± 0.6 Pt 1000 IEC 751; = 0.0035, 1995 200 to 300 32 to 572 ± 0.0 ± 0.72 Ni 120 Edison Curve No. 7 70 to 300 9 to 572 ± 0.30 ± 0.5 Cu 10 Edison Copper Winding No. 15 50 to 250 5 to 2 ± 3.20 ± 5.76 Cu 100 (a=2) GOST 6651-9 -15 to 200-365 to 392 ± 0. ±0.6 Cu 50 (a=2) GOST 6651-9 -15 to 200-365 to 392 ± 0.96 ±1.73 Cu 100 (a=26) GOST 6651-9 -50 to 200-122 to 392 ± 0. ±0.6 Cu 50 (a=26) GOST 6651-9 -50 to 200-122 to 392 ± 0.96 ±1.73 Thermocouples Cold Junction dds + 0.5 C to Listed ccuracy NIST Type B (ccuracy varies NIST Monograph 175 100 to 300 212 to 572 ± 6.00 ± 10.0 according to input range) 301 to 120 573 to 330 ± 1.5 ± 2.7 NIST Type E NIST Monograph 175 50 to 1000 5 to 132 ± 0.0 ± 0.72 NIST Type J NIST Monograph 175 10 to 760 292 to 100 ± 0.70 ± 1.26 NIST Type K NIST Monograph 175 10 to 1372 292 to 2502 ± 1.00 ± 1.0 NIST Type N NIST Monograph 175 200 to 1300 32 to 2372 ± 1.00 ± 1.0 NIST Type R NIST Monograph 175 0 to 176 32 to 321 ± 1.50 ± 2.70 NIST Type S NIST Monograph 175 0 to 176 32 to 321 ± 1.0 ± 2.52 NIST Type T NIST Monograph 175 200 to 00 32 to 752 ± 0.70 ± 1.26 DIN L DIN 3710 200 to 900 32 to 1652 ± 0.70 ± 1.26 DIN U DIN 3710 200 to 600 32 to 1112 ± 0.70 ± 1.26 w5re26 STME 9-96 0 to 2000 32 to 3632 ± 1.60 ± 2. GOST Type L GOST R.55-2001 -200 to 00-392 to 172 ± 0.71 ±1.2 Millivolt Input (1) Not approved for use with CS Option Code I6 10 to 100 mv ± 0.05 mv 2- and 3-Wire Ohm Input 0 to 2000 ohms ± 0.90 ohm Multipoint Sensors (2) (1) 20 m inputs are scaled to 20 100 mv. (2) Multipoint (up to points) thermocouples and RTDs are available for purchase with the Rosemount T. Input ranges and accuracy for these sensors will ccuracy Notes Differential capability exists between any two sensor types: For all differential configurations, the input range is X to +Y where X = Sensor 1 minimum - Sensor 2 max. Y = Sensor 1 maximum - Sensor 2 min. ccuracy for differential configurations: If sensor types are similar (for example, both RTDs or both thermocouples), the accuracy = 1.5 times worst case accuracy of either sensor type. If sensor types are dissimilar (for example, one RTD and one thermocouple), the accuracy = Sensor 1 ccuracy + Sensor 2 ccuracy. 5

Rosemount T Product Data Sheet 0013-0100-697, Rev F MBIENT TEMPERTURE EFFECT Transmitters may be installed in locations where the ambient temperature is between 0 and 5 C ( 0 and 15 F). TBLE 2. mbient Temperature Effects NIST Type ccuracy per 1.0 C (1. F) Change in mbient Temperature (1) C Temperature Range ( C) RTD Pt 100 (α = 0.0035) 0.003 C (0.005 F) N Pt 100 (α = 0.003916) 0.003 C (0.005 F) N Pt 500, Pt 1000, Ni 120 0.003 C (0.005 F) N Pt 200 0.00 C (0.0072 F) N Cu 10 0.03 C (0.05 F) N Cu 100 (a=2) 0.002 C (0.0036 F) N Cu 50 (a=2) 0.00 C (.0072 F) N Cu 100 (a=26) 0.002 C (0.0036 F) N Cu 50 (a=26) 0.00 C (.0072 F) N Thermocouple (R = the value of the reading) Type B 0.01 C 0.032 C - (0.0025% of (R - 300)) 0.05 C - (0.011% of (R - 100)) N R 1000 300 R < 1000 100 R < 300 Type E 0.005 C + (0.0003% of R) ll Type J, DIN Type L 0.005 C + (0.00029% of R) 0.005 C + (0.0025% of R ) Type K 0.0061 C + (0.0005% of R) 0.0061 C + (0.0025% of R ) R 0 R < 0 R 0 R < 0 Type N 0.006 C + (0.00036% of R) ll Type R, Type S 0.016 C 0.023 C - (0.0036% of R) Type T, DIN Type U 0.006 C 0.006 C - (0.003% of R ) GOST Type L 0.007 > 0 C 0.007 ± 0.003% < 0 C R 200 R < 200 R 0 R < 0 Millivolt 0.0005 mv N 2- and 3-wire Ohm 0.00 ohms N (1) Change in ambient is in reference to the calibration temperature of the transmitter (20 C (6 F) typical from the factory). mbient Temperature Notes Examples: When using a Pt 100 (a = 0.0035) sensor input and the transmitter is at 0 C ambient temperature, temperature effects would be: 0.003 C x (0-20) = 0.06 C. Worst case error would be: Sensor ccuracy + Temperature Effects = 0.30 C + 0.06 = 0.36 C. Total Probable Error = nalog to Fieldbus Performance 20 m inputs are scaled to 20 100 mv. ccuracy (1) :0.0625% of span Temperature Effect: [0.002% of reading + 0.000625% of span] per 1.0 C change in mbient Temperature. (1) To obtain accuracy, the mv input must be calibrated while 0.30 2 + 0.06 2 = 0.31 C 6

0013-0100-697, Rev F Rosemount T 7

Rosemount T Product Data Sheet 0013-0100-697, Rev F Product Certifications HZRDOUS LOCTIONS CERTIFICTION North merican Certificates Factory Mutual (FM) Certifications I5 Intrinsically Safety Intrinsically Safe for use in Class I, Division 1, Groups, B,C, D; when installed per Rosemount drawing 00-02. Temperature Code: T amb = 0 to 60 C IE FISCO (Fieldbus Intrinsically Safe Concept) Intrinsic Safety Intrinsically safe for use in Class I, Division 1, Groups, B,C, D; when installed in accordance with Rosemount Drawing 00-02. Temperature Code: T amb = 0 to 60 C Non-incendive for use in Class I, Division 2, Groups, B, C, D (suitable for use with non-incendive field wiring); when installed in accordance with Rosemount Drawing 00-02. Temperature Code: Ta (T amb = 0 to 5 C) T5 (T amb = 0 to 70 C) TBLE 3. Entity Parameters Power/Bus Sensor U i = 17.5 V U o = 12.02 V I i = 30 m I o = 13.5 m P i = 5.32 W P o = 0.0W C i = 2.1 nf C a = 1.36 µf L i = 0 L a = 160 mh N5 Non-incendive for use in Class I, Division 2, Groups, B, C, D (suitable for use with non-incendive field wiring) when installed in accordance with Rosemount Drawing 00-02. Temperature Code: Ta (T amb = 0 to 5 C) T5 (T amb = 0 to 70 C) Indoor Hazardous (Classified) Locations TBLE. FM pproved Entity Parameters (1) Power/Bus Sensor U i = 30 V U o = 12.02 V I i = 300 m I o = 13.6 m P i = 1.3 W P o = 0.0 W C i = 2.1 nf C a = 1.36 µf L i = 0 L a = 160 mh (1) Intrinsically safe and non-incendive parameters Canadian Standards ssociation (CS) Certifications E6 (1) Explosion-Proof For use in Class I, Division 1, 2, Groups B, C, D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups E and F. Dust-Ignition Proof For use in Class II, Division 1, Groups E, F, and G; Suitable for Class I, Division 2, Groups, B, C, and D, when installed per Rosemount drawing 00-101, CS Enclosure Type X (T amb = -50 to 5 C); Conduit seal not required. I6 Intrinsic Safety For use in Class I, Division 1, Groups, B, C, D; when installed per Rosemount drawing 00-03. Temperature Code: T3C (T amb = 50 to 60 C) Suitable for Class I, Division 2, Groups, B, C, D. Rated 2. VDC max. IF TBLE 5. CS pproved Entity Parameters Power/Bus Sensor U i = 30 V U o = 12.02 V I i = 300 m I o = 11. m C i = 2.1 nf C a = 1.36 µf L i = 0 L a = 225 mh FISCO (Fieldbus Intrinsically Safe Concept) Intrinsic Safety For use in Class I, Division 1, Groups, B, C, D; when installed per Rosemount drawing 00-03. Temperature Code: T3C (T amb = 50 to 60 C) Suitable for Class I, Division 2, Groups, B, C, D. Rated 2. VDC max. TBLE 6. CS pproved Entity Parameters Power/Bus Sensor U i = 17.5 V U o = 12.02 V I i = 30 m I o = 11. m C i = 2.1 nf C a = 1.36 µf L i = 0 L a = 225 mh N6 Class I, Division 2 Suitable for use in Class I, Division 2, Groups, B, C, D; when installed per Rosemount drawing 00-03. Temperature Code: T3C (T amb = 50 to 60 C) Must be installed in a suitable enclosure as determined acceptable by the local inspection authority. (1) Consult factory for the latest approval information.

0013-0100-697, Rev F Rosemount T European Certifications CENELEC Certifications I1 Intrinsic Safety Certification Number: Baseefa02TEX0010X TEX Marking II 1 G EEx ia IIC T (T amb = 50 to 60 C) 110 TBLE 7. CENELEC pproved Entity Parameters Power/Bus Sensor U i = 30 V U o = 12.5 V I i = 300 m I o = 66 m P i = 1.3 W P o = 0 mw C i = 0 C i = 0 L i = 0 L i = 0 Special Conditions for Safe Use (x): This apparatus must be installed in an enclosure which affords it a degree of protection of at least IP20. Non-metallic enclosures must have a surface resistance of less than 1G ohm, light alloy or zirconium enclosures must be protected from impact and friction when installed. The apparatus will not meet the 500V rms isolation test required by Clause 6..12 on EN50 020:199 when the optional transient protection (FISCO) board is fitted and this must be taken into account when installing the apparatus. I FISCO (Fieldbus Intrinsically Safe Concept) Intrinsic Safety Certification Number: Baseefa02TEX0010X TEX Marking II 1 G EEx ia IIC T (T amb = 50 to 60 C) 110 TBLE. CENELEC pproved Entity Parameters Power/Bus Sensor U i = 17.5 V U o = 12.5 V I i = 30 m I o = 66 m P i = 5.32 W P o = 0 mw C i = 0 C i = 0 L i = 0 L i = 0 Special Conditions for Safe Use (x): This apparatus must be installed in an enclosure which affords it a degree of protection of at least IP20. Non-metallic enclosures must have a surface resistance of less than 1G ohm, light alloy or zirconium enclosures must be protected from impact and friction when installed. The apparatus will not meet the 500V rms isolation test required by Clause 6..12 on EN50 020:199 when the optional transient protection (FISCO) board is fitted and this must be taken into account when installing the apparatus. N1 CENELEC Type n Certification Number: BS01TEX3199X TEX Marking II 3 G EEx nl IIC T5 (T amb = 0 to 65 C) TBLE 9. Entity Parameters Power/Bus Sensor U i = 2. V U o = 5 V C i = 0 I o = 2.5 m L i = 0 C o = 1000 µf L o = 1000 mh Special Conditions for Safe Use (x): 1. Provisions shall be made, external to the apparatus, to prevent the rated voltage (2. V dc) being exceeded by transient disturbances of more than 0%. 2. The ambient temperature range of use shall be the most restrictive of the apparatus, cable gland, or blanking plug. NC CENELEC Type n Component Certification Number: BS01TEX319U TEX Marking II 3 G EEx nl IIC T (T amb = 50 to 5 C) EEx nl IIC T5 (T amb = 50 to 70 C) Special Conditions for Safe Use (x): 1. The component must be housed in a suitably certified enclosure. 2. Provision shall be made, external to the component, to prevent the rated voltage (2.V d.c.) being exceeded by transient disturbances of more than 0%. ND CENELEC Dust Ignition Proof Certification Number: BS01TEX1315X TEX Marking II 1 D T90C (T amb = 0 to 65 C) IP66 Special Conditions for Safe Use (x): 1. The user must ensure that the maximum rated voltage and current (2.2 volts, 22 m, DC) are not exceeded. ll connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN50020. 2. Component approved EEx e cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. ny unused cable entry holes must be filled with component approved EEx e blanking plugs.. The ambient temperature range of use shall be the most restrictive of the apparatus, cable gland, or blanking plug. NE BSEEF/CENELEC TEX TYPE 'n' PPROVL Certification Number: BS01TEX3199X TEX Marking II 3 G EEx n nl IIC T5 (T amb = -0 to 65 C) NOTE: NE is valid with S001 Input Type ONLY. TBLE 10. Baseefa pproved Entity Parameters Power/Bus Sensor U i = 2. V U o = 5 V dc C i = 0 I o = 2.5 m L i = 0 C o = 1000 µf L o = 1000 mh Special Conditions of Safe Use (x): 1. Provisions shall be made, external to the apparatus, to prevent the rated voltage (2.2V dc) being exceeded by transient disturbances of more than 0%. 2. The ambient temperature range of use shall be the most restrictive of the apparatus, cable gland or blanking plug. 9

Rosemount T Product Data Sheet 0013-0100-697, Rev F NF COMPONENT pproval Certification Number: BS01TEX319U TEX Marking II 3 G EEx n nl IIC T (T amb = -50 to 5 C) EEx n nl IIC T5 (T amb = -50 to 70 C) NOTE: NF is valid with S001 Input Type ONLY.. TBLE 11. Baseefa pproved Entity Parameters Power/Bus Sensor U i = 2. V U o = 5 V dc C i = 0 I o = 2.5 m L i = 0 C o = 1000 µf L o = 1000 mh Brazilian Certifications Centro de Pesquisas de Energia Eletrica (CEPEL) pproval NOTE Consult factory for CEPEL availability. Special Conditions of Safe Use (x): 1. The component must be housed in a suitable certified enclosure. 2. Same as condition 1 for Cert: BS01TEX319U ustralian Certifications Standard ustralia Quality ssurance Service (S) NOTE Consult factory for S availability. I7 Intrinsic Safety Ex ia IIC T (T amb = 0 to 60 C) IG IECEx FISCO Ex ia IIC T (T amb = 0 to 60 C) N7 Type n Ex n IIC T (T amb = 50 to 5 C) Ex n IIC T5 (T amb = 50 to 70 C) Conditions of Safe Use (x): 1. The T shall be used according to its input and output parameters. 2. For Ex ia applications, the equipment is to be DIN-rail mounted in an IP20 area, mounted in a Rosemount Junction Box Option Code JPx, Jx, or JSx, or mounted in any suitable enclosure rated to a minimum of IP20. 3. For Ex n applications, the equipment is to be mounted in a Rosemount Junction Box Option Code JPx, Jx, or JSx, or mounted in any suitable enclosure rated to a minimum of IP5.. When installed in an enclosure, cable glands are to selected and used to ensure a minimum rating of IP20 for Ex ia equipment or a minimum rating of IP5 for Ex n equipment. Unused cable glands or conduit entries are to be closed to ensure the required IP rating is maintained. 5. When the equipment is to be installed and used in accordance with the FISCO concept, the transient protection option is to be fitted. 6. The sensor terminals are for use with passive temperature sensors only (resistance or thermocouple) that are classed as simple devices. 10

0013-0100-697, Rev F Rosemount T Dimensional Drawings Junction Boxes with no entries (option codes JP1, J1, and JS1) external dimensions are the same as those outlined for the other junction box materials in this section. Rosemount T Security Switch Top View 3-D View Side View 6.7 (170) Simulation Switch 3.7 (93) Removable Wiring Connection 1.7 (3) S P. E 2 _ 1 0-0 0, 1 _ 0 1 0-0 0, 6 6 _ Dimensions are in inches (millimeters) luminum/plastic Junction Box Cable Gland (option codes J2 and JP2) Top View 10.2 (260) 3-D View Ground Screw Front View Side View 1.57 (0) 2. (62) 1.73 () 7. (199.2) 6.30 (160).1 (112) _ 2.2 (5) 1.10 (2) 3.7 (96) Dimensions are in inches (millimeters) 11

Rosemount T Product Data Sheet 0013-0100-697, Rev F Stainless Steel Junction Box Cable Gland (option code JS2) Top View 9.91 (231) 3-D View 7.7 (196) Ground Screw Front View 1. (6) 1.1 (2) 1.73 () Side View 9.1 (232.2) 7.72 (196) 6.61 (16) 9 _.0 (102) 2. (62) 1.2 (30) 1. (7) Dimensions are in inches (millimeters) luminum/plastic Junction Box Conduit Entry (option codes J3 and JP3) Top View 10.2 (260) 3-D View Front View 157 (0) 2. (62) Side View 10.2 (260) 3.5 (9) 1.7 (2) Five Plugged 0.6-in. diameter holes suitable for installing 1 /2-in. NPT fittings Dimensions are in inches (millimeters) 0 5 _ 12

0013-0100-697, Rev F Rosemount T Stainless Steel Junction Box Conduit Entry (option code JS3) Top View 9.1 (231) 7.7 (196) 3-D View Ground Screw Front View 1. (35) 1.1 (27) 2. (70) Side View 1.2 (30) 2. (62) 1.6 (2) 0.06 (1.5).0 (102) 1. (.7) Five Plugged 0.6-in. diameter holes suitable for installing 1 /2-in. NPT fittings Dimensions are in inches (millimeters) 1 5 _ MOUNTING OPTIONS luminum/plastic Junction Box (styles J and JP) Stainless Steel Junction Box (style JS) Front View Side View Front View Side View 5.1 (130) 10.2 (260) 6.6 (167) fully assembled.5 (11) 7.5 (190) fully assembled B, 3 5, B, 2 5 _ Dimensions are in inches (millimeters) luminum/plastic Junction Box Mounted on a Vertical Pipe Stainless Steel Junction Box Mounted on a Vertical Pipe 5 5, 5 _ 13

Rosemount T Product Data Sheet 0013-0100-697, Rev F Ordering Information Model T Code F Product Description Multisensor Transmitter Temperature Inputs Communications Protocol FOUNDTION fieldbus digital signal (includes I, MI, and ISEL function blocks, and Backup Link ctive Scheduler) Code Product Certifications (1) Box required? Rosemount Junction I5 FM Intrinsic Safety No IE FM FISCO (Fieldbus Intrinsically Safe Concept) No N5 FM Class I, Division 2, and Dust Ignition Proof Yes E6 CS Explosion-Proof pproval Yes (2) I6 CS Intrinsic Safety No IF CS FISCO (Fieldbus Intrinsically Safe Concept) No N6 CS Class I, Division 2, & Dust Ignition Proof No (3) I1 TEX Intrinsic Safety No I TEX FISCO (Fieldbus Intrinsically Safe Concept) No N1 TEX Type n (EEx nl) Yes NC TEX Type n Component (EEx nl) No () ND TEX Dust Ignition Proof Yes NE (5) TEX Type n (EEx n nl) No (6) NF (5) TEX Type n Component (EEx n nl) No () I7 IECEx Intrinsic Safety No IG IECEx FISCO (Fieldbus Intrinsically Safe Concept) No () N7 IECEx Type n pproval (Ex nc) No () N No pproval No Code Input Types S001 Resistance Temperature Detectors and Thermocouples S002 (7) RTDs, Thermocouples, and 20 m Code Options Transient Protection T1 Transient Protection Mounting Kit Options B6 Mounting Bracket for 2-in. pipe mounting and for panel mounting SST bracket and bolts Non Explosion-Proof Junction Box Plastic Junction Box JP1 No Entries JP2 Cable Glands (9 x M20 nickel-plated brass glands for 7.5 11.9 mm unarmored cable) JP3 Conduit Entries (5 plugged holes, suitable for installing 1 /2-in. NPT fittings) luminum Junction Box J1 No Entries J2 Cable Glands (9 x M20 nickel-plated brass glands for 7.5 11.9 mm unarmored cable) J3 Conduit Entries (5 plugged holes, suitable for installing 1 /2-in. NPT fittings) Stainless Steel Junction Box JS1 No Entries JS2 Cable Glands (9 x M20 nickel-plated brass glands for 7.5 11.9 mm unarmored cable) JS3 Conduit Entries (5 plugged holes, suitable for installing 1 /2-in. NPT fittings) Explosion-Proof Junction Box JX3 Conduit Entries ( plugged holes, suitable for installing 1 /2-in. NPT fittings) Options continued on next page 1

0013-0100-697, Rev F Rosemount T Model Product Description Custom Software Configuration Request C1 Factory configuration of date, descriptor, and message fields (CDS required) Configuration Options () F5 50 Hz Line Voltage Filter Calibration Certification Q 3 Point Calibration Certificate Provided Conduit Electrical Connector GE (9) M12, -pin, Male Connector (eurofast ) GM (9) size Mini, -pin, Male Connector (minifast ) Typical Model Number: T F I5 S001 T1 B6 J2 (1) Consult factory for availability. (2) Enclosure Option JX3 must be ordered with Product Certification Code E6. (3) Must be installed in a suitable enclosure as determined by the local inspection authority. () The Rosemount T ordered with option code NC is not approved as a stand-alone unit. dditional system certification is required. (5) vailable only with S001 option (6) The Rosemount T must be installed so it is protected to at least the requirements of IP5; ll listed Junction Boxes fulfill this requirement. (7) S002 is only available with Product Certification N5, N6, N1, NC. () Configuration is the same for all eight inputs. (9) vailable with Intrinsically Safe approvals only. For FM Intrinsically Safe (option code I5), install in accordance with Rosemount drawing 00-02. Transmitter Tag Hardware tagged in accordance with customer requirements permanently attached to the transmitter Software the transmitter can store up to 30 characters if no characters are specified, the first 30 characters of the hardware tag will be used Sensor Tag Hardware a provided plastic tag to record identification of eight sensors this information can be printed at the factory upon request in the field, the tag can be removed, printed onto, and reattached to the transmitter Software if sensor tagging is requested, the Sensor Transducer Block sensor_sn parameters will be set at the factory the sensor_sn parameters can be updated in the field Wiring 1 2 3 2-wire RTD and Ohms Rosemount T Sensor Wiring Diagram + - 1 2 3 1 2 3 1 2 3 3-wire RTD Thermocouples 2-Wire RTD with and Ohms* and Millivolts Compensation Loop** * Rosemount provides -wire sensors for all single-element RTDs. Use these RTDs in 3-wire configurations by clipping the fourth lead or leaving it disconnected and insulated with electrical tape. ** The transmitter must be configured for a 3-wire RTD in order to recognize an RTD with a compensation loop. Rosemount T nalog Input Wiring Diagram 20 m Transmitter * Optional nalog Connector required. Transmitter Configuration The transmitter is available with the standard configuration setting. The configuration settings and block configuration may be changed in the field with the Fisher-Rosemount Systems DeltaV, with MSinside, or other FOUNDTION fieldbus host or configuration tool. Standard Configuration Unless otherwise specified, the transmitter will be shipped as follows for all eight sensors: Standard Configuration Settings Sensor Type (1) Thermocouple Type J Damping (1) 5 seconds Measurement Units (1) C Output (1) Linear with Temperature Line Voltage Filter (1) 60 Hz Temperature Specific Measurement Transducer Block (1) Blocks Sensor Transducer Block () Differential Transducer Block () FOUNDTION fieldbus Function Blocks (1) For all eight sensors VDC + + 1 2 20 m to 20 100 mv * nalog Input () Multiple nalog Input (1) Input Selector () 15

Rosemount T Product Data Sheet 0013-0100-697, Rev F Rosemount T Configuration Data Sheet Customer Information Customer P.O. Number Model No. Line Item Physical Device Tag Function Block Type (select one only) Damping Enable Write Protect One Multiple nalog Input Block (alarms not supported) Separate nalog Input Blocks ll eight sensors to be configured the same as Sensor 1 (fill out Sensor 1 only). Otherwise, fill out each sensor individually. Sensor 1 Sensor 2 Sensor 3 Sensor Tag Tag Tag Tag Type Type Type Type mv mv mv mv Ohms Ohms Ohms Ohms Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) None None None None Number of Leads Number of Leads Number of Leads Number of Leads 2-wire 3-wire 2-wire 3-wire 2-wire 3-wire 2-wire 3-wire Measurement Point Measurement Point Measurement Point Measurement Point LO LO LO LO HI HI HI HI Units Units Units Units mv C mv C mv C mv C Ohms F Ohms F Ohms F Ohms F K R K R K R K R larms (1) larms (1) larms (1) larms (1) HI HI larm HI HI larm HI HI larm HI HI larm HI larm HI larm HI larm HI larm LO larm LO larm LO larm LO larm LO LO larm LO LO larm LO LO larm LO LO larm 16

0013-0100-697, Rev F Rosemount T Sensor 5 Sensor 6 Sensor 7 Sensor Tag Tag Tag Tag Type Type Type Type mv mv mv mv Ohms Ohms Ohms Ohms Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 35 (IEC 751) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 100, α = 392 (IEC 160) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 200, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Pt 500, α = 35 (IEC 751) Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 10, Edison No. 7 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Cu 100, α = 2 Cu 50, α = 2 Cu 100, α = 26 Cu 50, α = 26 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Ni 120, Edison No. 15 Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) Type B Thermocouple Type C Thermocouple (NIST 175) Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type N Thermocouple Type S Thermocouple Type T Thermocouple Pt 1000, α = 35 (IEC 751) Type L Thermocouple (GOST R.55-2001) None None None None Number of Leads Number of Leads Number of Leads Number of Leads 2-wire 3-wire 2-wire 3-wire 2-wire 3-wire 2-wire 3-wire Measurement Point Measurement Point Measurement Point Measurement Point LO LO LO LO HI HI HI HI Units Units Units Units mv C mv C mv C mv C Ohms F Ohms F Ohms F Ohms F K R K R K R K R larms (1) larms (1) larms (1) larms (1) HI HI larm HI HI larm HI HI larm HI HI larm HI larm HI larm HI larm HI larm LO larm LO larm LO larm LO larm LO LO larm LO LO larm LO LO larm LO LO larm (1) Not applicable for MI blocks 17

Rosemount T Product Data Sheet 0013-0100-697, Rev F NOTES 1

0013-0100-697, Rev F Rosemount T 19

0013-0100-697, Rev F Rosemount T Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HRT is a registered trademark of the HRT Communication Foundation. FOUNDTION is a trademark of the Fieldbus Foundation. DeltaV is a mark of one of the Emerson Process Management companies. ll other marks are the property of their respective owners. Emerson Process Management Rosemount Inc. Emerson Process Management Emerson Process Management sia 200 Market Boulevard Heath Place Pacific Private Limited Chanhassen, MN 55317 US Bognor Regis 1 Pandan Crescent T (U.S.) 1-00-999-9307 West Sussex PO22 9SH Singapore 1261 T (International) (952) 906- England T (65) 6777 211 F (952) 99-7001 Tel (123) 63 121 F (65) 6777 097 Fax (123) 67 55 Enquiries@P.EmersonProcess.com www.rosemount.com 0013-0100-697, 2006 Rosemount, Inc.