Combination of Input/Output Control using Matrix Converter for Islanded Operation for AC generator

Similar documents
High Efficiency Power Conversion Using a Matrix Converter

Verification of Effectiveness of a Matrix Converter with Boost-up AC Chopper by Using an IPM Motor

Experimental Verification of High Frequency Link DC-AC Converter using Pulse Density Modulation at Secondary Matrix Converter.

Highly-Reliable Fly-back-based PV Micro-inverter Applying Power Decoupling Capability without Additional Components

Multi-Modular Isolated Three-Phase AC-DC Converter for Rapid Charging with Autonomous Distributed Control

RECENTLY, the harmonics current in a power grid can

Improvement of Light Load Efficiency for Buck- Boost DC-DC converter with ZVS using Switched Auxiliary Inductors

An Experimental Verification and Analysis of a Single-phase to Three-phase Matrix Converter using PDM Control Method for High-frequency Applications

Output Voltage Correction of an Induction Motor Drive Using a Disturbance Observer with Speed Sensor-less Vector Control Method

Novel Control Strategy for Single-Phase to Three-Phase Power Converter Using an Active Buffer

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Direct Grid Connection of Permanent Magnet Synchronus Motor Using Auxiliary Inverter and Matrix Converter with Transition Control

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

A Series-LC-Filtered Active Damper for AC Power Electronics Based Power Systems

Motor Performance Investigation of an Indirect Matrix Converter with a Reactor Free Boost Converter

Indirect Current Control of LCL Based Shunt Active Power Filter

Hybrid Commutation Method with Current Direction Estimation for Three-phase-to-single-phase Matrix Converter

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Current THD Reduction for High-Power-Density LCL-Filter-Based. Grid-Tied Inverter Operated in Discontinuous Current Mode

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Harmonic Stability in Renewable Energy Systems: An Overview

A Novel Engine Generator System with Active Filter and UPS Functions

A New Single-Phase PFC Rectifier (TOKUSADA Rectifier ) with Wide Output Voltage Control Range and High Efficiency

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

RECENTLY, energy sources such as wind power systems,

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Power Factor Improvement with Single Phase Diode Rectifier in Interior Permanent Magnet Motor

A Current-Source Active Power Filter with a New DC Filter Structure

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

THE output voltage of a power converter requires high accuracy

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

Lecture 19 - Single-phase square-wave inverter

ACTIVE POWER ELECTRONIC TRANSFORMER A STANDARD BUILDING BLOCK FOR SMART GRID

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Pulse Density Modulation Control using Space Vector Modulation for a Single-phase to Three-phase Indirect Matrix Converter

CHAPTER 1 INTRODUCTION

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Design and Simulation of Passive Filter

Active Rectifier in Microgrid

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

HARMONIC contamination, due to the increment of nonlinear

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Development of Inductive Power Transfer System for Excavator under Large Load Fluctuation

Performance Analysis of The Simple Low Cost Buck-Boost Ac-Ac Converter

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

THE converter usually employed for single-phase power

DC/DC Boost Converter Functionality in a Three-phase Indirect Matrix Converter

Recent Approaches to Develop High Frequency Power Converters

Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

High Efficiency Isolated DC/DC Converter using Series Voltage Compensation. Abstract. 1. Introduction. 2. Proposed Converter

Single switch three-phase ac to dc converter with reduced voltage stress and current total harmonic distortion

CHAPTER 3 MODIFIED SINE PWM VSI FED INDUCTION MOTOR DRIVE

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

Compensation for Neutral Point Potential in Three-Level Inverter by using Motor Currents

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

International Journal of Advance Research in Engineering, Science & Technology

Reduction in Radiation Noise Level for Inductive Power Transfer System with Spread Spectrum

Power Quality enhancement of a distribution line with DSTATCOM

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website:

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Hathiram Guguloth, Santosh A

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Eyenubo, O. J. & Otuagoma, S. O.

Multilevel Inverter Based Statcom For Power System Load Balancing System

University of Kurdistan. Adaptive virtual impedance scheme for selective compensation of voltage unbalance and harmonics in microgrids

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

A Review on Improvement of Power Quality using D-STATCOM

Two-step commutation for Isolated DC-AC Converter with Matrix Converter

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

DESIGN OF A WIND POWER GENERATION SYSTEM USING A PERMANENT MAGNET SYNCHRONOUS MACHINE, A BOOST REGULATOR AND A TRANSFORMER-LESS STEP DOWN CIRCUIT

Analysis of Utility Interactive Photovoltaic Generation System using a Single Power Static Inverter

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Improved direct torque control of induction motor with dither injection

IMPROVED TRANSFORMERLESS INVERTER WITH COMMON-MODE LEAKAGE CURRENT ELIMINATION FOR A PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEM

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

Electrical Motor Power Measurement & Analysis

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

NEW ACTIVE POWER FILTER WITH SIMPLE LOW COST STRUCTURE WITHOUT TLJNED FILTERS

ISSN Vol.03,Issue.07, August-2015, Pages:

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Multilevel Inverter Based on Resonant Switched Capacitor Converter

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

Speed Control of Induction Motor using Multilevel Inverter

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Compensation for Multilevel Voltage Waveform Generated by Dual Inverter System

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

The Feedback PI controller for Buck-Boost converter combining KY and Buck converter

Hybrid Matrix Converter Based on Instantaneous Reactive Power Theory

Transcription:

Combination of Input/Output Control using Matrix Converter for Islanded Operation for AC generator Jun-ichi Itoh Dept. of Electrical Engineering Nagaoka University of Technology Nagaoka, Niigata, Japan itoh@vos.nagaokaut.ac.jp Takuya Kataoka, Hiroki Takahashi Dept. of Electrical Engineering Nagaoka University of Technology Nagaoka, Niigata, Japan takuya_kataoka@stn.nagaokaut.ac.jp Abstract This paper proposes a control method of a matrix converter in a micro grid system to obtain stable islanded operation. The islanded operation using a matrix converter needs a voltage feedback control to assume the matrix converter as a constant voltage power supply for the load. On the other hand, the islanded operation also requires a generator current control with a feedback to determine provided power. However, when the matrix converter is applied two feedback controls on the generator side and the load side, the interference between both controls occurs and the matrix converter becomes unstable. This instability occurs due to difference of instantaneous active powers between the generator side and the load side; therefore, the active power is determined by the voltage source converter only. The active current which is needed to control the filter capacitor voltage should be converted to the generator current command as an active power command. Thereby, the proposed control method avoids the interference, and achieves a stable islanded operation. In addition, the proposed control also offers a constant three-phase voltage to the load even if the load power is light because of a compensation of a reactive current into the filter capacitor. As a result, the proposed control method achieves stable islanded operation and unity displacement power factor of the load side. The load current THD (Total harmonic distortion) is 1.4%, and the filter capacitor voltage THD is 1.5%. In the experiment, the load voltage is a sinusoidal waveform of 2 V. In addition, the load voltage THD is 4.56%. Therefore, it is confirmed that the proposed control method achieves stable operation without the interference. This paper confirms validity of the proposed control in the islanded operation by simulation and fundamental experiment. Keywords islanded operation; matrix converter; micro grid I. INTRODUCTION Recently, a matrix converter, which directly converts AC power supply voltage into AC voltage of variable amplitude and frequency without large energy storage such as electrolytic capacitor, has been actively studied [1-3]. A matrix converter has advantages over a conventional BTB (back to back) system which is composed of a PWM rectifier and a PWM inverter on the following aspects; size reduction, light-weight, long-life and high efficiency power supplies. These indexes are very important for renewable energy systems Matrix converters can be applied in generation systems, such as a wind turbine generators, micro-hydro power plant, bio-diesel engine generator, and so on [4]. Lately, it also has been considered to apply a matrix converter to a micro grid system and distributed generation system. In these applications, the generator is commonly connected as an input voltage source of matrix converters [5-6]. In addition, micro gird systems consist of distributed generators and loads in small area such as a remote island which cannot interconnect commercial grid. Thereby, matrix converters in the micro grid need a capability of an islanded operation to continue delivering power from the generator to the load [7]. However, a matrix converter in an islanded operation has a problem. In this application, matrix converters need a voltage feedback control to guarantee reliability as a constant voltage power supply for the load. On the other hand, the matrix converter also requires a generator current control with a feedback to determine provided power. Due to these two feedback controls, the interference between both controls occurs and leads to instability of the matrix converter [8]. The instability is triggered because instantaneous active powers of the input and output sides are determined by both controls independently. However, a matrix converter does not have energy storages; therefore, a matrix converter becomes unstable because of the difference between both instantaneous active powers. However, solutions for this issue have been reported rarely. Previous studies regarding the island operation using a matrix converter have been discussed in [6] and [8]. In past work, a matrix converter is connected to a generator and a motor [8]. This work achieves controls of a generator current and an output voltage in the islanded operation. However, the generator should be used in high speed region only because the high voltage side of a matrix converter is connected to the generator. In addition, the terminal voltage of the generator and the input current are unstable due to a filter resonance between the synchronous reactance of the generator and the input capacitor. Thereby, the control is more complex due to suppressing control for the filter resonance. On the other hand, a matrix converter for a distributed generation achieves islanded operation [6]. This work achieves the islanded operation at rated power. However, this work does not confirm the operation in area of light load. In this paper, in order to solve problem about the instability, a control method for the islanded operation in a matrix

converter is proposed. The proposed method has two feedback controls for the filter capacitor voltage and the generator current. However, the instability is avoided because the proposed method combines these feedback controls and only the generator current control determines the active power of the converter. As a result, the interference is not triggered and a stable islanded operation obtained. In addition, the proposed control compensates an effect of a reactive current into the filter capacitor and offers a constant three-phase voltage to the load even when the load power is light. In this paper, the stability of islanded operation is evaluated in simulation and fundamental experiment. II. CIRCUIT CONFIGURATION AND CONTROL TRATEGY A. Circuit configuration Fig.1 shows a circuit diagram of an interface converter between a generator and a load using a matrix converter. In this system, a low voltage side of the matrix converter is connected to the generator, and high voltage side is connected to the load. By this connection, the generator is utilized in wide speed region though the opposite connection restricts the generator operation in high speed region only. A matrix converter requires LC filter in the load side to eliminate harmonic current due to switching operation. B. Virtual AC-DC-AC conveter control method In order to simplify the control techniques, a virtual AC- DC-AC conversion technique which has been discussed in [9] is referred. Fig.2 shows an equivalent circuit of the matrix converter in Fig.1 using an AC-DC-AC converter, which is based on the virtual AC-DC-AC conversion technique. In Fig.1 and Fig.2, the input voltage is represented as t [v r,v s,v t] and the output voltage is represented as t [v u,v v,v w]. xy represents the switching function of the switches, when xy is turned on, xy =1 and when xy is turned off, xy =. According to the virtual AC-DC- AC conversion theory, the PWM pattern for the matrix converter can be converted by the following equation. ru rv rw su sv sw tu tv tw up vp wp un vn wn As a result, control performance of the matrix converter is exactly same as the AC-DC-AC converter because the relationship between input voltage and the output voltage is the same. It should be noted that the relationship between input current and output current is also the same. Thus, the switching pulses of the matrix converter are generated easily because the proposed control method can considered with a voltage source converter and a current source inverter. C. Control strategy of islanded operaiton Fig.3 shows a PWM pulse generator based on the virtual AC-DC-AC conversion technique. This diagram combines switching pulses generated by a virtual converter and a virtual inverter controls and synthesizes switching pulses of the matrix rp rn sp sn tp tn (1) v gen G Generator i gen R T ru rv rw su sv sw tu tv tw Matrix converter i laod converter according to (1). The voltage source converter control is fed input voltage command v r, v s, v t from the generator current control. imilarly, the current source inverter control is fed output current command i u, i v, i w from the filter capacitor voltage control on the load side. Then, the virtual converter is applied discontinuous PWM method for improvement of a voltage transfer ratio. In contrast, the virtual inverter uses single leg modulation [9]. Fig.4 shows the proposed control block diagram for the islanded operation. The proposed control method is based on d- q frame because the d-q frame defines the d-axis as a reactive component and the q-axis as an active component although the generator frequency is different from the grid frequency. Thereby, the active power is simply controlled on the d-q frame. Fig.4(a) shows a control block diagram of the generator current control. This control is for determining the instantaneous active power from the generator and this control uses a feedback controller as well as a voltage source converter due to applying the virtual AC-DC-AC conversion technique. Then, gen is a rotor angle of the generator, i r, i s, i t are detected value of three phase generator current, v r, v s, v t are input voltage command for the voltage source converter, and P load is active power command from the filter capacitor voltage control on the load side. fe is back-emf constant of generator. gen is determined by integrating the generator rotation speed gen. An ACR (Auto current regulator) block has a PI regulator in order to control the generator current i dgen, i qgen. In the case, the d-axis generator current command i dgen is always fixed to p.u. for U V W v c LC filter Load Fig. 1. Interface converter between a generator and a load using matrix converter v gen G i gen Generator R T rp sp tp wp vp up U V W i laod rn sn tn wn vn un LC filter Voltage orce Converter Current orce Inverter v c Load Fig. 2. Equivalent circuit using AC-DC-AC converter. This circuit is used based on the virtual AC-DC-AC conversion technique in order to simplify the control techniques.

achieving unity input displacement power factor. Furthermore, the q-axis current i qgen is calculated by the active power and detected q-axis induced voltage of the generator. Fig.4(b) shows control block diagram of the filter capacitor voltage control on the load side. This control is for the islanded operation which assumes the matrix converter as a constant voltage power supply to the load. This control employs a feedback controller as well as a current source inverter due to applying the virtual AC-DC-AC conversion technique. Then, v u, v v, v w are detected filter capacitor voltage, i u, i v, i w are output current command for the current source inverter, and load is phase angle of the load current. In order to supply the generator power to the load as well as a grid, load is determined by integrating the grid frequency. An AVR (Auto voltage regulator) block has a PI regulator in order to control the load voltage. In the case, the d-axis load voltage command v dload is always fixed to p.u. for achieving unity output displacement power factor. On the other hand, output of the q- axis AVR is not used in the current source inverter and the q- axis current command i qload is set to 1. This is to avoid the interference of the active power between the generator current control and the filter capacitor control and the principle is as following. The active current command i qload is needed to control the q-axis voltage of the filter capacitor v qload. However, if the current source inverter is fed the active current command i qload from the feedback controller, the feedback controls of the generator side and the load side determine each required active power independently. This is because the generator current control decides the input voltage command with referring the generator current and the filter capacitor voltage control decides the output current command with referring the filter capacitor voltage, which is equivalent to determine the instantaneous power. Thus, because of the difference between both required instantaneous active powers, the matrix converter becomes unstable. In order to avoid the interference, the active current command of the current source inverter should be fed with an open loop as shown in Fig.4(b), which does not contribute to the active power. As a result, the active power is determined by the voltage source converter only and a stable islanded operation is achieved. In contrast, a reactive power does not exist in DC link. Thereby, the power transmitted between the generator and the load through the matrix converter is only active component, as shown in Fig.2. Hence, the active current which is needed to control the filter capacitor voltage should be converted to the generator current command as an active power command. Therefore, Fig. 4 uses the active power command P load. Moreover, the output of the d-axis AVR adjusts the output power factor of the matrix converter because the d-axis current command of the current source inverter affects the reactive current. Thus using the output of the d-axis AVR is equivalent to compensation of the reactive current caused by the filter capacitor and this compensation contributes to supplying a constant voltage to the connected load at the light load area in the islanded operation. v r,v s,v t i u,i v,i w Voltage source converter control Current source inverter control PWM Composition Eq.(1) Fig. 3. witching pulse generator K g =1/v gen_rated i dgen = v dgen K g P load i qgen v qgen v qload load v dload v qload i dgen i qgen ACR ACR 3 K g (a) Generator current control AVR AVR 3 III. IMULATION REULT The simulation parameters are as follows, the generator induced voltage is 1V (line to line), the frequency of a generator is 5Hz, the switching frequency is 1 khz, and the cut-off frequency of LC filter is 1 khz. Note that the simulation is running in a RL load condition. Fig.5 shows the generator side and the load side waveform in steady state with the interference between the generator current and the filter capacitor voltage controls. In this simulation, the generator current control and the filter capacitor voltage control work independently. The load resister is 26.6 and the load inductor is 2.55 mh (3%). This simulation confirms unstable islanded operation without the proposed control method. In this simulation, the active powers of the generator side and load side are independently determined by both controls As a result, the load current and the filter capacitor voltage is not sinusoidal waveform and these waveforms have distortion. Thereby, the operation of the matrix converter is instability. 6 6 gen K L =1/(-i load_rated ) K i dload L i qload =1 3 v qgen 3 9 witching pulse v r,v s,v t 1 s fe (b) Filter capacitor voltage control on the load side i r,i s,i t gen i u,i v,i w P load v u,v v,v w Fig. 4. Control block diagram for islanded operation. This diagram is separated into the generator current control and the filter capacitor voltage control on the load side. This control obtains stability for islanded operation without interference between the feedback controls on the generator and the load sides.

1 1-1 3-1 2-3 3-2 2-3 1-2 1-1 1 [ms/div] Fig.5. imulation results of the islanded operation without proposed control. This waveform is unstable due to the interference. -1 1 [ms/div] Fig.6. imulation results of the islanded operation with proposed control in steady state at rated power. 1 1-1 25 2-1 2-2 -25 25 2-2 25 2-2 -25 1-2 -25 1-1 Load power fluctuation (.1 p.u. to 1p.u.) 2 [ms/div] -1 Load power fluctuation (1 p.u. to.1 p.u.) 2 [ms/div] Fig.7. imulation results of a load fluctuation under the islanded operation. The load power is changed from.1 p.u. to 1 p.u. Fig.6 shows the generator side and the load side waveform in a steady state with the proposed control method. The load resister is 26.6 and the load inductor is 2.55 mh (3%). In addition the matrix converter outputs 1.5kW (1p.u.). As a result, the film capacitor phase voltage is sinusoidal wave and this RM voltage value is 115 V (line to line voltage is 2 V.). The generator current THD (Total Harmonics Distortion) is.8%, the load current THD is 1.4%, and the film capacitor voltage THD is 1.5%. The proposed control method achieves unity displacement power factor of the generator side and the load side. These results lead to a conclusion that the proposed control obtains the stable islanded operation. Fig.7 and Fig.8 show the generator side and the load side waveform in a load fluctuation by changing a load resister. In Fig.7, the load resister value is changed to 266 from 26.6. The output power of the matrix converter changes to.15 kw (.1p.u.) from 1.5kW (1p.u.). In Fig.8, the load resister value is changed to 26.6 from 266. The output power of the matrix converter changes to 1.5 kw (1p.u.) from.15kw (.1p.u.). As results, although the output power is Fig.8. imulation results of a load fluctuation under the islanded operation. The load power is changed from 1 p.u. to.1 p.u. varied, the output voltage is maintained to a constant voltage of 115 V except a transient state regardless the load power. This is because of the compensation of the reactive current caused by the filter capacitor. Thereby, the validity of the proposed control method is confirmed. IV. EXPERIMENTAL REULT Table 1 shows experimental parameters. The proposed method is based on a virtual AC-DC-AC conversion technique. Therefore, the parameters of ACR and AVR are designed as well as conventional design methods in a voltage source inverter and a current source converter. Fig.9 shows a circuit diagram of the matrix converter in an experiment. In Fig.9, a magnetic contactor is added to separate the grid connected operation and the islanded operation. The generator is replaced with a three-phase voltage source of 1 V and input inductors in order to simplify the experiment.

A. Grid connected operation In the grid connection operation, an open loop control is applied to the grid side of the matrix converter. The q-axis input current command i qgen is fed by an open-loop control instead of P load and the d-axis output current command i dload is set to zero. Additionally, in order to connect the grid, the magnetic contactor is closed. Fig.1. shows the input and the output waveform in the grid connected test. The generator current and the grid current are sinusoidal waveform with the THD of 4.88% and 8.65%, respectively. In addition, the matrix converter operates in the unity displacement power factor on the generator and the grid sides because i dgen and i dload are zero. As a result, it is confirmed that the matrix converter achieved stable operation in grid connected operation. B. Islanded operation In the islanded operation, the proposed control method is applied to the matrix converter in order to obtain a stable operation without the interference. By opening the magnetic contactor, the matrix converter is separated from the grid. Fig.11 shows the input and the output waveform in the islanded operation when a load resister R load is 32.5 (1.22 p.u.). In this case, the matrix converter outputs approximately 1-kW power (.66p.u.). The load voltage is sinusoidal waveform of 2 V owing to the filter capacitor voltage control. In Fig. 11, the generator current THD is 4.94%, the load voltage THD is 4.56%. In addition, the displacement power factors on the generator side and the grid side are unity. As a result, it is confirmed that the proposed control method achieves a stable operation and a load voltage control without the interference. Fig.12 shows the input and output waveform in the islanded operation when a load resister R load is 75 (2.81 p.u.), which is lower power than Fig. 11. The matrix converter outputs approximately.5-kw power (.33p.u.). By the proposed method, the load voltage becomes a sinusoidal waveform of 2 V in the same manner as Fig. 12. However, the generator current and the load voltage distortion contain more because the filter capacitor is small and the bandwidth of the filter capacitor voltage control is limited. This will be improved in the future by establishing a design method of the PI controller and the LC filter. Therefore, the proposed method achieves a stable operation without depending on a load power. V. CONCLUION This paper discusses a control method for the islanded operation using a matrix converter. In order to guarantee reliability as a constant voltage power supply for the load, the load voltage control is applied. In addition, the generator current to determining control to determine provided power is also introduced. However, these two feedback controls may cause unstable operation because of the interference between both controls in terms of the active power. In order to solve this problem, this paper proposes a control which combines the generator current control and the load voltage control, and the generator current only decides the active power due to avoid K p (ACR) TABLE I. Gnerator voltage Generator frequency v gen Input L T i (ACR) K p (AVR) T i (AVR) G i gen Generator R T 1 V rms 5 Hz 3. mh (3.5%) 1.38 p.u. 21.1 ms.5 p.u. 4.67ms EXPERIMENTAL PARAMETER ru rv rw su sv sw tu tv tw Grid voltage Grid frequency Filter L (%Z) Filter C (%Y) Dampng resister (Damping Factor) Output power Carrier frequency i load U Magnetic Contactor 2 V rms 5 Hz 2.2 mh (2.6%) 4.5mF (3.8%) 47 (.24) 1.5 kw 1 kw interference of difference of instantaneous active powers between the generator side and the load side. As a result, the proposed control method avoids the interference, and achieves the stable operation of the islanded operation. In simulation result, proposed control method achieves stable islanded operation. The load current THD is 1.4%, and the film capacitor voltage THD is 1.5% at rated load. In addition, in order to compensate a reactive current into the filter capacitor, the proposed method offers a constant three-phase voltage to the load even when the load power is light. In the experiment, it is confirmed that the proposed control method achieves the stable operation and the load voltage control without the interference. Then, the generator current THD is 4.94%, the V W v c Load Resister grid Fig. 9. Experimental circuit diagram. The operation mode is switched by the magnetic contactor. Grid voltage(line to line) 25V/div Generator voltage(line to line) 25V/div Grid current 5A/div 1ms/div Generator current 1A/div Fig. 1. Experimental results of the grid connected test in steady state. The generator supplies power to the grid through the matrix converter.

load voltage THD is 4.56%, and the load current THD is 4.94%. From these results, the validity of the proposed control method for the islanded operation is demonstrated. In the future, usefulness of the proposed method will be confirmed in the islanded operation when a nonlinear load such as a diode rectifier is connected. Load voltage(line to line) 25V/div Load current 5A/div REFERENCE [1] J.Rodriguez,M.Rivera,J.W.Kolar A Review of Control and Modulation Methods for Matrix Converter,IEEE Trans.Ind.Electoron,, vol. 59 No.1, pp. 58-7(211) [2] T.Friedli, J.W.Kolar Milestone in Matrix Converter Research, IEEJ Jornal I.A.,vol1.,No.1, pp2-14(212) [3] P.W.Wheeler, J.Rodriguez, J.C.Clare, L.Empringham: Matrix Converters: A thecnology review, IEEE Trans.Ind.Electron., vol.49,no.2,pp.274-288(22) [4] R. Cardenas,R. Peña, P. Wheeler, J. Clare, Control of the Reactive Power upplied by a WEC Based on an Induction Generator Fed by a Matrix Converter,IEEE Trans. Ind. Elec. Vol.56, No.2, pp.429-438 (28) [5] more authorsh.hojabri, H.Mokhtari, L.Chang, Reactive Power Control of Permanent-Magnet ynchronous Wind Generator With Matrix Converter, IEEE Trans. P.D.,vol.28,No.2,pp.575-584(213) [6] Xiong Liu, Poh Chiang Loh, Peng Wang, F.Blaabjerg, Distributed Generation Using Indirect Matrix Converter in Reverse Power Mode, IEEE Trans. Power Electoron., vol.28, No.3, pp.172-182.(211) [7] Jinwei He, Yun Wei Li, F.Blaabjerg, An Enhanced Islanding Microgrid Reactive Power, Imbalance Power, and Harmonic Power haring cheme,ieee Trans. Power Electron.,vol.3,No.6,pp3389-341(215) [8] J. Haruna and J. Itoh: "Control trategy for a Matrix Converter with a Generator and a Motor," The Applied Power Electronics Conference and Exposition (APEC 211) [9] J. Itoh, I. ato, H. Ohguchi, K. ato, A. Odaka and N. Eguchi: A Control Method for the Matrix Converter Based on Virtual AC/DC/AC Conversion Using Carrier Comparison Method, Trans. IEEJ, Vol.124- D, No.5, p457 (24) Generator voltage(line to line) 25V/div 1ms/div Generator current 1A/div Fig. 11. Experimental results of the islanded operation in steady state with R Load=37.5. The load voltage is sinusoidal waveform of 2 V. Load voltage(line to line) 25V/div Generator voltage(line to line) 25V/div Load current 2A/div 1ms/div Generator current 5A/div Fig. 12. Experimental results of the islanded operation in steady state with R Load=75. The proposed method achieves stable operation without depending on the load power