Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Similar documents
SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Mineral-insulated resistance thermometers to EN

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance Thermometers Model Series TR7X0, Sheathed Design

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

FC-33, DC SELECTABLE SIGNAL CONDITIONER

2002-ALM USER MANUAL

Screw-in resistance thermometers with plug connector

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

STANDARD RTD's INDEX

ED701 General Industry Pressure Transmitter

CONTA-ELECTRONICS. Converter Units

Welding Cables Rubber Insulated

Model TL Linearized Platinum Resistance Thermometer Temperature Transmitter Instruction Manual

Troubleshooting RTDs and Thermocouples

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

OPTITEMP TT 20 Technical Datasheet

Burns Engineering Presents - FAQ s that we ll answer today. Acronyms and Terminology. Acronyms and Terminology. Q & A on Temperature Topics

Materials (other materials see WIKA diaphragm seal program) Model S-10

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

SHIMADEN DIGITAL INDICATORS

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

S T T U S I N S T R U M E N T S

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Additel 875 Series Dry Well Calibrators

TxBlock-USB Transmitter

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Dissolved Oxygen Transmitter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

MODEL: M2DYS SEN TRONIC AG

MODEL: R30US4. Remote I/O R30 Series

Resistance thermometer Model TR31, miniature design

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

Electronic Thermostat TE-1 Version according to EN

Technical Information itemp TMT180

OMEGA. EWSE Series. Rugged, Weatherproof Temperature Sensors and Transmitters. 1.0 Description. 2.0 Receiving and Unpacking

High-precision process calibrator Model CED7000

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

SHIMADEN DIGITAL INDICATORS

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

1000TR. Instructions

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

ThermoPLUS Smart Temperature Transmitter

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

F4-08RTD 8-Channel RTD Input

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Isolators A3/1.

MODEL: W2TS. Mini-MW Series

Sample Specification Electrical Heat Tracing Cables Metric Units

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

P5201 Universal Programmable Transmitters with Galvanic Isolation

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

protim-r Module

SOLAR-360 : 360 Inclinometer, RS232 or RS485 Output

Analogue Temperature Transmitter

Ouput Loop Powered Products Section C

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

Miniature Temptran RTD Transmitters

SRS SEALED ROTARY SENSORS

Assembly. Front view. Parametrization interface. Power Bus

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Additel 875 Series Dry Well Calibrators

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

CR0603/CR0805/CR Chip Resistors

SLC 500 RTD/Resistance Input Modules

Resistance thermometers for process technology

Local control stations for Zone 1 and Zone 21. Features. Description

RTD TH17 and TH18. Technical Information. Sanitary RTD temperature assembly with connection head

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

The Rosemount 848T Wireless Temperature Transmitter

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Temperature and Humidity Probes. Code Max Temp ( C) Resistance 25 C) Accuracy 0 to 70 C)

Fuzzy Temperature Controllers E5AF

Magnetostrictive Level Transmitter

Pressure transmitter for general industrial applications Model A-10

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

4-20mA, 0-10V and general process measuring bargraph displays

SITRANS T measuring instruments for temperature

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Humidity Sensor/Transmitter Assembly

GEXOL WORLD CLASS OIL & GAS CABLES

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Transcription:

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects to any standard Pt100 resistance sensor and converts the linearised temperature to a (4 to 20) ma signal. The transmitter is a two wire device, and is fully configurable by the user over a wide temperature range, with the aid of a simple push button. This design incorporates additional configuration menus, allowing the user to push button trim the transmitter output at both zero and span, ideal for trimming out sensor errors. The transmitters advanced circuitry guaranties high stability over the wide operating ambient temperature ranges experienced by head mounted devices. One of the transmitters features is the program LED, which provides visual indication of sensor fault when in normal operation and is also used to guide the operator through the simple menus during configuration. Ordering Information Type Allied code RS Order Number Pt100 70825787 363-0238 SPECIFICATION @ 20 C INPUT Sensor Type PT100 100 R @ 0 C 2 or 3 Wire Sensor Range (-200 to +850) C (18 to 390) Ω Sensor Connection Screw terminal Minimum span (see note 1) 25 C Linearisation BS EN 60751(IEC 751) standard / JISC1604 Accuracy (see note 2) ±0.1 C±0.05% of Reading Thermal Drift 0.0025 % / C Excitation current < 200 ua Lead Resistance effect 0.002 C/ Ω Maximum lead Resistance 20 Ω per leg Note 1 Any span may be selected, full accuracy is only guaranteed for spans greater than the minimum recommended span. Note 2 Basic measurement accuracy includes the effects of calibration, linearisation and repeatability

OUTPUT Type Two wire Limits Accuracy Loop Effect Thermal Drift Max Load (4 to 20) ma sink Low 3.8 ma; high 21.5 ma ± (ma out / 2000) or ±5 ua which ever greater ± 0.2 au / V measured @ 50 Hz 1 V (peak to peak) ± 1 ua / C typical; ±1.5 ua Max [ (V supply 10)/20] KΩ GENERAL Update Time 0.5 Seconds Response Time 1 Second to reach 90% of final value Start-up time From power up typically 5 Seconds Filter Factor Adaptive Ambient Temperature (-40 to 85) C Connection Screw Terminal Approvals BS EN 61326; 1998 Electrical equipment for measurement and control ANNEX A; ANNEX F Factory Default (0 to 100) C upscale burnout (0.0 C user trim) Mechanical The RTD transmitter has been specifically designed to fit inside a DIN standard probe head enclosure which provides adequate protection from moisture, dust, corrosive atmosphere etc. All cable entries must be sealed using the correct size gland. Likewise, any probe assembly fitted must be sealed. Care must be taken when locating the transmitter to ensure the working ambient temperature range of (-40 to 85) C is not exceeded. The transmitter enclosure has a centre hole allowing the sensor wired to enter screw terminals from the transmitter centre, this is applicable when the sensor is mounted directly below the transmitter. Electrical Electrical connections to the transmitter are made to the screw terminal provided on the top face. The sensor wires must be equal length and type for the lead compensation to work correctly. The screw terminals allow for wires to enter either inner or outer direction. The transmitter is protected against reverse connection and over voltage. If no sensor (input) connection is made the transmitter will go into either up or down scale output current, depending on configuration. The wiring diagram below gives connection details; the output is shown connected to a 24 V supply. The load symbol represents any other device connected in the loop, such as Monitoring equipment, panel indicators and loop isolators. The load value can range from 0 ohms to the max loop load for given supply. The transmitter conforms with EC directive BS EN 61326: 1998 when correctly installed in a termination head providing at least IP20 protection and with sensor wires less than 3 metres. Screened or twisted pair wires are recommended for output wires. Always ensure the (4 to 20) ma loop is grounded at one point, this would normally be at the monitoring equipment or loop power supply. In normal operation the program LED acts as over-range LED. Wiring Diagram Dimensions

Need RTD Cable or Pt100/Pt1000 Detectors? RTD Extension Cable 4 core (10 or 25 metre reel) Platinum Resistance Thermometer Extension Cable Silicone Rubber Insulated Silicone rubber insulated cable for extending Platinum Resistance Thermometers Can be used to extend up to 4 wire RTD configurations Commonly used with Pt100Ω thermometers but suitable with other types Pt130/500/1000Ω etc. 4 core silicone rubber insulated 7/0.2mm tin plated copper conductors, twisted together with silicone rubber outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 Good electrical and mechanical properties, highly flexible, resistant to oils, acids and other adverse fluids Good heat resistance up to 200 C Insulation rating -40 C to 200 C Supplied in 10 or 25 metre reel lengths Type Conductors mm² Cores (4 core) Jacket Reel Length Allied RS order Code Code RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 10 metres 70657147 827-5823 RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 25 metres 70644361 455-4242 Overall sheath Dimension (approx.) 4.0mmØ

RTD Extension Cable 4 & 6 core PFA Platinum Resistance Thermometer Extension Cable, PFA insulated & screened 4 core (cores: 2 x red / 2 white) 6 core (cores: 4 x red / 2 x white) PFA insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, extruded PFA Teflon construction Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 & 6 core available to extend 2, 3 or 4 wire RTD configurations, the 6 core can be used to extend 2 x 3 wire duplex (dual element) configurations Construction PFA insulated 7/0.2mm tin plated copper conductors, twisted cores with nylon cord, tin plated copper braided screen with PFA insulated outer jacket Cores colour coded Red & White in accordance with IEC-751, black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids Insulation rating -75 C to 260 C See below for available reel lengths Type Conductors mm² Cores Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 x 4 Yes Black 10 metres 70646175 611-8078 RTD 7/0.2mm 0.219 x 4 Yes Black 25 metres 70646176 611-8090 RTD 7/0.2mm 0.219 x 4 Yes Black 50 metres 70657148 827-5827 RTD 7/0.2mm 0.219 x 4 Yes Black 100 metres 70657150 827-5836 RTD 7/0.2mm 0.219 x 6 Yes Black 25 metres 70646177 611-8107 RTD 7/0.2mm 0.219 x 6 Yes Black 50 metres 70657151 827-5839 Overall sheath Dimension (approx.) 4 core: 3.2mmØ 6 core: 3.8mmØ

RTD Extension Cable 4 core PTFE (10 & 25 reel lengths) Platinum Resistance Thermometer Extension Cable, PTFE insulated & screened PTFE insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, wrapped PTFE tape construction Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PTFE insulated 7/0.2mm silver plated copper conductors, twisted cores, Mylar tape, silver plated copper braided screen with PTFE insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 + black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids, steam, gasses etc. Insulation rating -75 C to 260 C Supplied in 10, & 25 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644773 492-9775 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642885 290-4976 Overall sheath Dimension (approx.) 3.5mmØ

RTD Extension Cable 4 core PVC (10, 25 & 50 reel lengths) Platinum Resistance Thermometer Extension Cable, PVC insulated & screened PVC insulated cable for extending Platinum Resistance Thermometers Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers but also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PVC insulated 7/0.2mm tin plated copper conductors, twisted cores, polyester tape & nylon cord, tin plated copper braided screen with PVC insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 with black outer jacket Heat resistant PVC to 105 C Good for general purpose cable, highly flexible & waterproof Insulation rating -10 C to 105 C Supplied in 10, 25 & 50 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644772 492-9753 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642884 290-4954 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 50 metres 70646179 611-8129 Overall sheath Dimension (approx.) 4.4mmØ

Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A, B and 1/3DIN For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: <0.5 C/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 2 x 5.0mm Class A 70646146 611-7788 Pt100 2 x 5.0mm Class B 70646148 611-7801 Pt100 2 x 5.0mm Class B 70642888 290-5070 (Packet of 5) Pt100 2 x 10mm Class A 70643577 362-9799 Pt100 2 x 10mm Class B 70641762 237-1607 Pt100 2.0 x 10mm 1/3DIN 70643578 362-9812 Pt100 2.0 x 2.3mm Class A 70643579 362-9834 Pt100 2.0 x 2.3mm Class B 70643580 362-9840 Pt100 2.0 x 2.3mm 1/3DIN 70643581 362-9856 Pt100 Elements (continued) Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 1.2 x 1.6mm Class A 70646834 666-7362 Pt100 1.2 x 1.6mm Class B 70646831 666-7353

Pt100 1.0 x 3.0mm Class A 70646833 666-7359 Pt100 1.0 x 3.0mm Class B 70646832 666-7356 Pt100 2.0 x 5.0mm 1/3 Din 70656467 814-0162 Pt100 1.2 x 4.0mm Class B 70656468 814-0165 Pt100 1.2 x 4.0mm Class A 70656469 814-0169 Pt1000 Elements, Thin Film (1000 Ohm) Pt1000 elements to IEC 751 Class A and B For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt1000 (1000 Ohms @0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 1000Ω Fundamental interval (0 C to 100 C): 385Ω (nominal) Self-heating: <0.5oC/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt1000 2.0 x 10.0mm Class A 70643582 362-9907 Pt1000 2.0 x 10.0mm Class B 70643583 362-9913 Pt1000 2.0 x 10.0mm 1/3 Din 70656472 814-0178 Pt1000 1.0 x 3.0mm Class B 70656470 814-0171 Pt1000 1.25 x 1.7mm Class B 70656471 814-0175

Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or B 100Ω Ohms @ 0 C Single or dual element Platinum coil wire-wound construction sealed inside a high purity alumina ceramic body Optimum performance & stability Temperature range 200 C to +650 C Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Wire-Wound, 10mm tails Temperature range: -200 C to +650 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: 0.02 to 0.3 C/mW Thermal response: <0.4s (secs. to 63% of final value in water @ 1m/s) Measuring current: 1mA Tolerance Class: In accordance with IEC 60751 W0.15 (Class A) -100 C to +450 C W0.3 (Class B) -196 C to +660 C Continued:

Single element: Resistance Tolerance Class Diameter ( D ) Length ( L ) Allied code RS order code Pt100 Class B 1.5mm 8mm 70646153 611-7851 Pt100 Class A 1.5mm 8mm 70646155 611-7873 Pt100 Class B 1.5mm 15mm 70646154 611-7867 Pt100 Class A 1.5mm 15mm 70646151 611-7839 Pt100 Class B 2.8mm 15mm 70646150 611-7823 Pt100 Class A 2.8mm 15mm 70646152 611-7845 Pt100 Class B 2.8mm 25mm 70646147 611-7794 Pt100 Class A 2.8mm 25mm 70646149 611-7817 Dual element: Pt100 (x2) Class A 1.5mm 15mm 70643873 397-1595 D L 10mm