INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

Similar documents
Mid-Power Expansion Unit (MxU) Quick Installation Sheet

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

This FAQ covers Single Direction use of current loop with transmitting devices.

This FAQ covers the common questions from technicians installing these converters.

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

SLC 500 RTD/Resistance Input Module

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

Universal RS232/CMOS to RS422/RS485 Converter

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

Interface converter G kbit/sec

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ControlNet Modular Repeater Medium Distance Fiber Module

Miniature Synchronous Multipoint Modems

FOM-4SF Sync/Async Single Fiber Modem

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

FOM-5A, 6A Asynchronous Fiber Optic Modems

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

Twelve Port Multi-Band Antenna

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

M9606. FSK Modem. 5C Communications Inc.

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Wireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case.

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

M-Bus Master MultiPort 250L Installation and User Guide

Ten Port Multi-Band Antenna

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

HexPort Multi-Band Antenna

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

HexPort Multi-Band Antenna

TriBand Antenna HPA65R-KE4A DATA SHEET

Concept of Serial Communication

Fanuc Serial (RS232) Communications Information

TriBand Twelve-Port Antenna

Twelve Port Multi-Band Antenna

Multi-Band Twelve-Port Antenna

OctoPort Multi-Band Antenna

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Ten Port Multi-Band Antenna

Cable and Port Specifications

Integrity Instruments

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Twelve Port Multi-Band Antenna

ZCS485 User s Manual. Version ZYPEX, Inc.

Ultra-wideband Bi-SectorTM Array

Multi-band Bi-Sector TM Array

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

MDW-45 Converter RS RS-422/485

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Hybrid Bi-SectorTM Array

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

SEL-3031 Quick-Start Guide

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

MDS SD4 Software-Controlled Digital Communications Firmware Release 1.x.x

Sasquatch User s Manual

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

There are many important factors when trying to achieve good, reliable communications between 2 devices.

Hybrid Bi-SectorTM Array

Thermocouple/mV Isolated Input Module

Atrie WireSpan 600/610 MODEM User's Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

RS-422/RS-485 Line Tester Model 485T

Accutech BR20. DIN rail mounted base radio

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

ATSBT-BOTTOM-FM-4G. Electrical Specifications. Product Classification. General Specifications. Mechanical Specifications. Bottom Smart Bias Tee

Ocean Controls KT-5221 Modbus IO Module

Hybrid Bi-SectorTM Array

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

Modem E1. Modem-converter E1-L. Features. Contents

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

ITL Basics of Encoding and Wiring

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

PACSystems* RX3i and Series 90-30

Chapter 12: Digital Modulation and Modems

1.0 Introduction. Related Products and Documentation

2- and 4-port Transceivers Piercing, N-type, and BNC

Contents. Warranty and Disclaimer 2

R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

3-FIBMB2 Fiber Optic Interface Module Installation Sheet

DS1000E, DS1000D Series Digital Oscilloscope

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

Specifications / Installation

XTL-FA-01 Edge Filter for Xenus: User Guide

Stat-4 Stat-8 Stat-24

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Contents. Warranty and Disclaimer 2 Introduction 3

OV-1000TSC OV-1000TLC/ Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter. User s Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

Transcription:

QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM

STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485 Repeater This Quick Start Guide USER-SUPPLIED COMPONENTS 10 to 48 VDC power supply; this repeater draws a maximum of 2.3 Watts. RS-232 cable; the converter is a DCE device. RS-422/485 cables. Recommended characteristics: 24 AWG twisted pair with a shunt capacitance of 16 pf per foot and 100 Ohm characteristic impedance. STEP 2 - Certifications & UL C1/D2 FCC Class A CE IEC 61850-3 IEEE 1613 UL CLASS 1 / DIVISION 2 WARNING INFORMATION SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY. CONVENANT À L EMPLOI DANS LES SITES DANGEREUX DE CLASSE I, DIVISION 2, GROUPES A, B, C ET D, OU DANS LES SITES NON HASARDEUX SEULEMENT. Field wiring connections must be made using 105 C minimum copper supply wires. Les connexions de câblage sur site doivent être réalisées en utilisant des câbles d alimentation en cuivre de 105 C minimum. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. ATTENTION - DANGER D EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA CLASSE I, DIVISION 2. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS. ATTENTION - DANGER D EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA CLASSE I, DIVISION 2.

STEP 3 - Front and Back Panels, DB9 Pin-out A B E D C Figure 1. Front Panel G F Figure 2. Back Panel TABLE 1. FRONT AND BACK PANELS A DB9 Female DCE port - see Section 4. B DB9 Male DTE port - see Section 4. C D Pin 3 LED Pin 7 LED Pin 2 LED Pin 8 LED Green, ON, when a TD input (Pin 3) is raised on the DCE port. Green, ON, when an RTS input (Pin 7) is raised on the DCE port. Green, ON, when an RD input (Pin 3) is raised on the DTE port. Green, ON, when a CTS input (Pin 8) is raised on the DTE port. E Power LED Red, ON when power is applied. Power Terminal F Block 2-position, removable (10 48 VDC), see Section 6. G Grounding Lug Chassis ground to earth ground, see Section 5.

STEP 4 - RS-232 Connections TD (Input) TD (Output) SG RD (Output) RD (Input) SG CTS (Output) RTS (Input) RTS (Output) CTS (Input) Figure 3. RS-232 Connectors Connect your RS-232 devices. A DTE device is Data Terminal Equipment ; this includes computers, PLCs, and most devices that are not used to extend communications. Think computer for DTE. A DCE device is Data Communications Equipment ; this includes devices intended to plug directly into a DTE port including modems and devices that extend communications like a modem, such as RS-422, RS-485, or fiber optic converters or radio modems. Think modem for DCE.

STEP 5 - Ground Connection Figure 4. Ground Connection Black Box recommends that you ground the chassis as shown in Figure 4: Connect a grounding wire from the ground lug to a good grounding source. STEP 6 - Power Connection Figure 6. Power Connections Connect the power. Power requirements: 10 to 48 VDC. This repeater draws a maximum of 1.5 Watts. The terminal block will accept 28 to 12 AWG wire.

STEP 7 - Loopback Test / Troubleshooting Figure 6. Connections for Loopback Testing. Black Box recommends: 1. Configure the converter for RS-485 4-wire. 2. Jumper terminals A to C and B to D. 3. Connect a PC to the RS-232 port (see Section 3). Use a DB9 female to DB9 male cable to connect a PC to the DCE port. 4. On the DTE port jumper Pin 2 to 3 and Pin 7 to 8 on the female end of the cable. This loops TD to RD and CTS to RTS. 5. Using hyperterminal or a similar program, connect to the appropriate COM port. Turn off hyperterminal local echo. 6. Transmit the data. The same data that was transmitted should be returned, and the LED indicators should light per the table should light per Table 1 in Section 3.