DURING the past 15 years the use of digitized

Similar documents
SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Introduction. MIA1 5/14/03 4:37 PM Page 1

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

SYLLABUS. 1. Identification of Subject:

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Digital Image Processing

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

Explain what is meant by a photon and state one of its main properties [2]

Digital Imaging CT & MR

Medical Images Analysis and Processing

Biomedical Imaging Informatics

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

JEFFERSON COLLEGE COURSE SYLLABUS BET220 DIAGNOSTIC IMAGING. 3 Credit Hours. Prepared by: Scott Sebaugh Date: 2/20/2012

CHAPTER 8 GENERIC PERFORMANCE MEASURES

10/26/2015. Study Harder

DICOM Conformance. DICOM Detailed Specification for Diagnostic Labs and Radiology Center Connectivity

Do you have any other questions? Please call us at (Toll Free) or , or

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

Photomultiplier Tube

10/15/2012 SECTION III - CHAPTER 6 DIGITAL FLUOROSCOPY RADT 3463 COMPUTERIZED IMAGING

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Introduction. Stefano Ferrari. Università degli Studi di Milano Methods for Image Processing. academic year

10/3/2012. Study Harder

COMPUTED TOMOGRAPHY 1

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?

Introduction, Review of Signals & Systems, Image Quality Metrics

Digital Images & Image Quality

Medical Imaging and its Associated Analysis

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September ISSN

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

PD233: Design of Biomedical Devices and Systems

Digital Image Processing and Machine Vision Fundamentals

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

CR Basics and FAQ. Overview. Historical Perspective

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

X-RAYS - NO UNAUTHORISED ENTRY

Digitization and fundamental techniques

Introduction, Review of Signals & Systems, Image Quality Metrics

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Multi-Access Biplane Lab

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Digital Image Management: the Basics

Computerized transverse axial scanning (tomography): Part I. Description of system

Investigation of Multiple Head Registration / Center of Rotation for SPECT Gamma Cameras

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Initial Certification

Chin J Radiol 2004; 29:

Chapter 3 Medical Image Processing

Acquisition, Processing and Display

Reconstruction Filtering in Industrial gamma-ray CT Application

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

Digital Image Fundamentals

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Outline ASRT Changes Impact on current curriculum Potential new courses WECM Changes Last update Resources and needs

Introduction to image processing

A Fast Monolithic System for Proton Imaging. Fritz DeJongh ProtonVDA Inc October 2017

Computed Tomography. The Fundamentals of... THE FUNDAMENTALS OF... Jason H. Launders, MSc. Current Technology

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Features and Weaknesses of Phantoms for CR/DR System Testing

UNIT 2 Medical Technology: Imaging Unit Overview I. Introduction

Medical Device Manufacturing: Designing for X-ray Inspection. Gil Zweig, President Glenbrook Technologies.

Digital Industrial Radiography

... In vivo imaging in Nuclear Medicine. 1957: Anger camera (X;Y) X Y

Biomedical Imaging and Image Analysis

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology

BASICS OF FLUOROSCOPY

Hardware for High Energy Applications 30 October 2009

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

CHAPTER 10. DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) 10.1 Introduction

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Attikon, Rimini 1, , Athens, Greece , Athens, Greece , Athens, Greece

An Activity in Computed Tomography

An Improved Phantom for Quality Control of Laser Scanner Digitizers in Picture Archival and Communications Systems

Seminar 8. Radiology S8 1

2. Sources of medical images and their general characteristics

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Digital Radiography. Selected Topics

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Setting up digital imaging department!

NM Module Section 2 6 th Edition Christian, Ch. 3

International Journal of Computer Engineering and Applications, TYPES OF NOISE IN DIGITAL IMAGE PROCESSING

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

SmartRAD. Advanced Digital Radiography System

X-Ray-Based Medical Imaging and Resolution

Multimodal Co-registration Using the Quantum GX, G8 PET/CT and IVIS Spectrum Imaging Systems

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

Measurement of table feed speed in modern CT

CT Basics: Equipment and Instrumentation Module 2

Overview of Safety Code 35

Transcription:

DIGITAL IMAGING BASICS Properties of Digital Images in Radiology DURING the past 15 years the use of digitized images in radiology has proliferated. It is reasonable to expect that within a few years virtually all radiologic images will be available in digital form and further, that this will be the predominant mode of image presentation within radiology. Historically, nuclear medical images were the first to be regularly digitized because they have relatively low resolution and contrast compared to other medical images.' The computer hardware available 15 years ago was so limited in both speed and capacity that only these low-information-content images could be efficiently handled in the digital regime. X-ray computed tomography (CT) of the early 1970s,2 a modality that is intrinsically digital in the sense that the output is a computed image, was the first modality to require a computer for image production and it naturally followed that the digital images produced would be displayed electronically. This modality has set the stage for the digital imaging revolution that is taking place today. For the first time, radiologists were exposed to the advantages of postacquisition image manipulation and began to accept the usefulness of such capability. Since the introduction of CT, there have been several developments in digital imaging including computer-dependent modalities such as magnetic resonance imaging (MRI)3.4 and the application of digital image acquisition and display methods to intrinsically analog modalities such as planar radiography and fluoroscopy" (called digital radiography or DR and sometimes digital fluoroscopy or DF) and real-time ultrasound (US).7,8 Further, the availability of digital images in the various modalities has led to the development of computationally-derived images which represent physiological quantities.t'" From the Department ofradiology. Massachusetts General Hospital. Boston. Address reprint requests to John A. Correia, PhD. Department of Radiology, Massachusetts General Hospital. 32 Fruit St. Boston MA 02114. 1988 by WB. Saunders Company. 0897-1889/88/0101-0006$03.00/0 John A. Correia and Nathaniel M. Alpert The major advantages of digital imaging over conventional film-based imaging are higher efficiency detection systems may be used thus limiting patient radiation dose, the possibility for post-acquisition-processing data exists, electronic displays, which have a high degree of flexibility, can be used, and digital images may be archived and retrieved efficiently from digital data bases. Because of the present and future impact of digital imaging, it is essential that the radiologist become familiar with digital image production, storage, and manipulation to most effectively practice his/her profession. It is the purpose of this article to address one aspect of this body of knowledge, namely the basic properties of digital images. The following sections include discussions of a number of these properties including digital image production, size, contrast, and storage. PROPERTIES OF A DIGITAL IMAGE A digital image can be thought of as a collection of digital storage elements such that there is a one-to-one correspondence between a location in the image field and a unit of digital storage. For example, the field encompassed by a plane film may be divided into discrete elements and the average value of x-ray absorption in each element assigned a unique digital location, or the value at a reconstructed CT image element may be assigned a similar unique location. In the case of a projection image such as a plane film, the element is called a pixel (a contraction of picture element) and in the case of a cross-sectional,volumetric modality such as CT it is called a voxel (volume element). It is convenient to think of such a digital image as a matrix having an x- and y-coordinate which uniquely specify the location of a given element (Fig 1). The number that specifices this location is called a "digital address" within a computer memory or mass storage device. The actual information within a computer memory or storage medium need not be organized in exactly this way. Typically, the digital image can be thought of as an N by M matrix 18 Journal of Digital Imaging, Vall. No 1 (November), 1988: pp 18-23

PROPERTIES OF DIGITAL IMAGES IN RADIOLOGY 19 1-------- N elements --M Original Dynamic Range -800 700 J Single Eleme-nt 3 Bil Digitization 2 J == 8 Levels Digitized Image Image Clement 500 400 J N x M Discrete Elements Original Image Resolution = R -0 Fig 1. Digital image matrix format showing x- and y-coordinates and one-to-one correspondence between image field location and digital image element. having N x M discrete elements. For computational convenience, N = M = i where 1is in the range of five to 11. This gives rise to matrices having from 1024 (32 x 32) to 4,194,304 (2048 x 2048) elements. The digital image size is related to the spatial resolution represented in a given image. Each element in a digital image is typically a byte (8 bits), a word (16 bits), or a long word (32 bits) representing, in integer format, the value of the image parameter associated with that image. In general an n bit integer can represent a range of numbers from 0 to 2" - 1. Thus a byte can represent a range from 0 to 255 while a word can represent a range from 0 to 65,536 as illustrated in Fig 2. This parameter is often called the "image depth" and is related to the fineness of the contrast differences that can be represented. CHOICE OF DIGITAL IMAGE SIZE The minimum number of elements needed to represent a digital image from a given modality depends on the intrinsic spatial resolution of that modality. This relationship arises from the need to have sufficient elements to represent the image without degradating its intrinsic resolu- Fig 2. Digital Image Digitization of contrast in each image element. tion and is dictated by a fundamental result of signal processing theory called the sampling theorern.!' The sampling theorem requires that for a given spatial resolution, R, defined by the physical limitations of the modality, it is necessary to have at least two image elements per resolution length to preserve the information in a digitized image. In practice, more than this number of elements is needed. For example, if a given image has a characteristic dimension I and a resolution R then a matrix with a dimension of at least 2ljR is required. In the case of a nuclear medicine device with resolution of 8 mm imaging a 300 mm object, one would require a matrix with at least 94 elements on a side, leading to a probable choice of a 128 2 matrix. Characteristic digital matrix sizes for other modalities for a 300 mm object are shown in Table 1. If a digital image does not meet the minimum spatial sampling requirement imposed by the sampling theorem, then information is lost in the digitization process. This may result in a phenomenon called aliasing in which artifacts or distortions are introduced into the image. An example of this in every day life is the appear- Table 1. Typical Digital Image Matrix Sizes for 300 mm Diameter Object in Various Imaging Modalities Modality Spatial Resolution (mm) Number of Samples (20/rl Minimum Matrix Commonly Used Matrix Nuclear medicine X-rayeT MRI DR Ultrasound 8.0 2.0 2.0 0.4 3.0 75 300 300 1500 200 75 2 320 2 300 2 2048 2 200 2 128 2 512 2 256 2 512 2 256 2

20 CORREIA AND ALPERT Fig 3. Example of aliasing. Bar phantom acquired on a Gamma Camera using a 512' matrix (AI and a 128" matrix (B). The higher resolution representation of the bars on the lower left is accurate while the lower resolution image shows an artifact consisting of thicker bars. ance in a television image of a superimposed pattern when an object containing parallel lines with spacing finer than the television's discrete vertical sampling of 525 lines is viewed. In medicine, these artifacts may manifest themselves as unwanted or distorted structures in the image as illustrated in Fig 3. In practice, it is sensible to choose a matrix size that is sufficient to represent the given image and not a larger one. The larger a matrix, the more mass storage it requires and the longer it takes to store, recover, transmit, and manipulate it. One of the factors that has limited, and perhaps still limits the digitization of some images, particularly very high resolution images such as planar radiographs, is that the storage required to digitize such images at full resolution is very large. For example, to preserve all the resolution in a chest film having 0.2 mm intrinsic resolution requires a matrix image size of 4096. 2 Until recently, the cost of storage and low transfer speed of matrices of this size within the computer and storage media have prohibited their use. However, a matrix size large enough to maintain the full resolution is not always necessary since the information content of the measured data rather than the resolution may be the limiting factor. Factors such as image contrast and structure size may contribute to defining information content. CHOICE OF IMAGE DEPTH The contrast resolution of an image is qualitatively defined as the fineness with which differences in the imaged parameter can be detected for a given image at a given resolution. An image may be described by the number of elements and the number of bits of contrast needed, for example 512 x 512 x 12 bits deep (also 512 2 by 12 bits). For images of parameters measured directly from ionizing radiation, the contrast resolution is limited by the number of photons detected. Since the detected photons follow Poisson statistics, contrast resolution is a percentage of the dynamic range of the values measured (0 to N) given by.jnin, where n is the average number of events recorded in a given image element. For CT images, there is some amplification of the basic Poisson noise due to the reconstruction process, but the relative behavior of the signal to noise ratio is similar to that for directly acquired images. In modalities such as MRI and US, the signal to noise ratio of the image elements depends on the amount of fluctuation in the measured signals and can be improved by the process of signal averaging in which the signal is measured multiple times and averaged. Typical contrast resolutions for the radiologic imaging modalities are given in Table 2. As is the case with spatial sampling, the undersarnpling of the contrast range of an image can cause artifacts. The most typical artifact is the appearance of false edges or contours in the image. These can be confused with true edges and structures resulting in errors in clinical findings. An example of such false contours is shown in Fig 4. Nuclear medical images, for example, have an intrinsic contrast of about 5% or a signal to noise ratio of 20 due to the limited number of photons

PROPERTIES OF DIGITAL IMAGES IN RADIOLOGY 21 Modality Table 2. Nuclear medicine/pet X-ray CT MRI DR Ultrasound Typical Contrast Resolution and Digital Image Depth for Medical Imaging Modalities Intrinsic Contrast (%) Minimum No. of Bits % Grey Levels Usual No. of Grey Levels 3.0 ~ 10 5 (6) 32 64 0.5 ~ 1.0 8 (16) 256 4096 1.0 ~ 3.0 8 (16) 256 4096 0.2 10 (8) 1024 256-1024 1.0 ~ 5.0 8 (4) 256 256 detected (typically about 500,000 events per image). This means that differences in contrast or radioactive density of 5% are detectable in adjacent image elements and smaller differences are not statistically significant. Since the same sampling theorem considerations apply to contrast, at least 40 discrete numbers are required to represent the information in an image element. In practice, a byte representing a range of 0 to 255 may be used if the data are normalized to that range. A CT image, on the other hand has a contrast resolution of 0.2% requiring at least Fig 4. PET brain image displayed with 64 (A). 16 (B) and 8 (C) grey levels. Artificial contours may be seen in the images with coarser grey scales. 1,000 discrete numbers. A word representing a range of 0 to 65,536 (actually ±32,678), the next convenient power of two, is used. A digital radiography image has similar contrast resolution. DIGITIZATION AND TEMPORAL RESOLUTION The process by which digital images are produced usually involves the conversion of an analog electrical signal such as a voltage, a current, or a television signal to digital spatial and contrast information. This transformation is achieved by an electronic device called an analog to digital converter (ADC). In devices such as scintillation cameras which have low event detection rates and x-ray CT scanners where a large number of individual detectors are served by multiple ADCs which digitize detector current, limitations on the digital conversion process are minor and digitized matrix sizes and depths appropriate to the information in the original data can be achieved in most instances. MRI also falls into this category since at anyone time, data associated with only one line making up the image are being digitized. In modalities such as digital fluoroscopy, where a television signal representing a whole image field is to be converted to a digital image, the properties of the resulting digital image are limited by the digitization rate of the ADC. The intrinsic television frame rate is 30 frames per second, the contrast of the fluoroscopic image would support a contrast range requiring up to 12 bits; the spatial resolution of the fluoroscopic image would support digital matrix sizes of up to 2,048 2 ; and the fastest ADCs commonly available today can digitize at a rate of about 10 million events per second. The combination of potentially large matrices, image depths, and potentially high frame rates requires that some tradeoff be made in digitizing these images. If an ADC which digitizes at a maximum rate of 10 Mbytesjsec is used, the required digitization rate to collect 30 frames per second of matrix size 512 2 and depth 12 bits would be approximately

22 CORREIA AND ALPERT 12 Mbytes per second, beyond the capacity of the ADC. The options available to overcome this problem are: (1) to give up spatial resolution by decreasing matrix size; (2) to give up contrast resolution by reducing depth; or (3) to give up temporal resolution by decreasing the number of frames per second collected. If high resolution television technology having 1,024 or 2,048 lines per screen is used, the problem becomes even more acute. The size of the field can be reduced by "coning down" the x-ray beam to preserve spatial resolution over a smaller field of interest at high frame rates. Another limitation of the digital image collection rate is the time required to transfer images internally in the computer, ie, the transfer of images along the computer communications bus and write times to mass storage disks. This problem can be moderated by designing special image acquisition memories that hold a large number of images coupled with special circuits which store data from the ADCs directly into the memory. Computer memory is relatively inexpensive today and storage systems containing 100 Mbytes are commonly available. Such a memory would hold ten of the digital fluoroscopy images described above. Having two independent memories and appropriate computer hardware would allow the uninterrupted collection of images at high rates by transferring data from one memory to mass storage while data is being acquired into the other. This technique is called double buffering, or when extended to multiple memories, multi-buffering. STORAGE OF DIGITAL IMAGES The overall storage required for a digital image of various modalities varies considerably as illustrated in Fig 5. The two parameters defining the digital image size, the spatial extent and the contrast depth, may be chosen to maximize storage capability. For example, dynamically acquired nuclear medical images, in which the intrinsic contrast resolution is poor due to statistical limitations, may be stored as 64 2 images having a bit depth of only 8 bits. While digital fluoroscopy images, which are typically limited by the speed of the ADCs which digitize television signals, are typically 512 2 as limited by the vertical resolution of the television camera and have signal to noise ratios which may require up to 12 bits of contrast resolution. Newer televi- Fig 5. Schematic representation of relative storage requirements for digital images of different sizes. sion technologies and direct digital detection systems will require image matrix sizes of 1,024 2 or even 2,048 2 to take full advantage of available resolution. Other modalities fall in between these extremes (Fig 5). CONCLUSION The use of digital images in radiology has become widespread and will likely become universal within radiology departments in the near future. Therefore, radiologists must be conversant with properties of digital images including spatial and contrast resolution and their implications in terms of their requirements in viewing and interpreting such images. -l 16

PROPERTIES OF DIGITAL IMAGES IN RADIOLOGY 23 1. Metz CE, Pizer SM, Brownell GL, (eds): Information Processing in Scintigraphy. United States Energy Research and Development Agency, Conference 730687,1973 2. Hounsfield GN: Computerized transverse axial scanning: Description of the system. Br J Radiol 46:1016-1022, 1973 3. Lauterbur PC: Image formation by induced local interactions: Examples employing nuclear magnetic resonance. Nature, 242:190-191,1973 4. Hinshaw WS, Andrew ER, Bottomley PA, et al: Display of cross-sectional anatomy by nuclera magnetic resonance imaging. Br J Radiol 51:273-280, 1978 5. Drew PG: The coming revolution in digital radiography. Diagn Imaging, 3:10-11, 1982 REFERENCES 6. Sackett JF, Crummy AB, Strother CM, et al: The computerized flouroscopy: Digital subtraction for IV angiography and arteriography. AJR 135:1131-1140, 1980 7. Wells PN: Biomedical Ultrasonics, San Diego, Academic, 1977 8. Wells PN: Real time scanning systems. Clin Diagn Ultrasound, 5:69-73, 1980 9. Phelps ME, Mazziotta JM, Huang SC: Study of cerebral function with positron computed tomography. J Cereb Blood Flow Metab, 2:113-162, 1982 10. Cahn J and Lassen NA (eds): New brain imaging techniques in cerebrovascular disease. Libbey Eurotext, 1985 11. Barrett HA and Swindell W: Radiologic Imaging, Volume I. San Diego, Academic, 1981