250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Similar documents
Two-Wire Programmable Transmitter for:

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Miniature Temptran RTD Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

ISOLATED 4-20 ma TRANSMITTERS

TT230 Series Thin Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

Isolated Transmitters: 600T Series

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT TEL: FAX:

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SMART TEMPERATURE TRANSMITTERS. smar

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Temperature transmitter itemp PCP DIN rail TMT 121

DRG-SC Series Signal Conditioners

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TIY Programmable, Isolated Thermocouple Transmitter combines

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AI-1500 Smart, Two-Wire Temperature Transmitter with HART Communications

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

itemp PA TMT184 Technical information

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

User's Manual: Series 250T Model 250T Frequency Input Two-Wire Transmitters

STT 3000 Smart Temperature Transmitter

Miniature Low-Cost Temperature Transmitters MTX

itemp HART DIN rail TMT112

Universal Intelligent 2-wire DIN Rail Transmitters

DIN Thermocouple Conditioner MODEL 5M14(V)

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

0 2 1 â Ó. itemp HART TMT182. Technical Information

The Rosemount 848T Wireless Temperature Transmitter

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

Instruction Manual. X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7: X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7: 24 VDC, 160 ma Max. (If special or required)

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 580 Digital Process Indicators Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Temperature Measurement Transmitters for mounting in sensor head

ORDERING INFORMATION T79D

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

FC Series Signal Conditioners

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

HART Compatible Intelligent 2-wire In-head Transmitters

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Temperature Measurement Transmitters for mounting in sensor head

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

HART field temperature transmitter Models TIF50, TIF52, TIF62

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature head transmitter itemp TC TMT 188

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire In-head Transmitters

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

General Specifications

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

7SD/7SH/7SM Temperature Controllers

Transmitters/Signal Conditioners

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Universal Intelligent 2-wire DIN Rail Transmitters

Rosemount 333 HART Tri-Loop

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

Temperature Transmitters - DIN Rail Mounted

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

MODEL SC170 TWO-WIRE SMART SIGNAL CONDITIONER INSTALLATION AND OPERATION MANUAL

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

P5201 Universal Programmable Transmitters with Galvanic Isolation

2002 IS Catalog. Page

Temperature Measurement

Nuclear Qualified Weed Instrument Model N7030 RTD and N7040 Thermocouple Analog Temperature Transmitter

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Temperature Transmitters - Head Mounted

Temperature Measurement

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Ouput Loop Powered Products Section C

TRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

R88000 T (including ATEX)

MODEL: W2TS. Mini-MW Series

high accuracy tester-calibrator PJ 6301

2002-ALM USER MANUAL

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

DP2000 ORDERING GUIDE To Order MODEL NO.

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Isolated 4 to 20 ma Transmitters For Demanding Applications Thermocouples, RTD (Pt100) or Ohms, Millivolts, Milliamps, Volts

Temperature transmitter itemp RTD DIN rail TMT 127

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Transcription:

Series Isolated Transmitters 250T Loop-Powered (2-wire) Transmitter PLC / DCS 250T S Sense Resistor P L IN Input Isolation OUT 4-20mA RLOAD 24V DC 350T DC-Powered (3-wire) Transmitter PLC / DCS 350T PWR P P L IN Input Isolation OUT V/mA RLOAD 24V DC Thermocouple Input These models convert sensor inputs to proportional process current or voltage output signals. Models 250T: Loop-powered transmitter series 350T: DC-powered transmitter series 450T: AC-powered transmitter series Input Ranges Thermocouple types J, K, T, R, S, E, B Linearized thermocouple (custom ranges) Output Ranges DC current: 4 to 20mA DC voltage: 0 to 5V or 0 to 10V Power Requirements 250T: 12 to 50V DC @ 20mA (loop-powered) 350T: DC voltage source (see table below) Output range Power 4 to 20mA 10 to 36V DC @ 30mA 0 to 5V 10 to 36V DC @ 9mA 0 to 10V 12.5 to 36V DC @ 9mA 450T: 115V or 230V AC, ±10%, 50 to 60Hz Output range Power 4 to 20mA 115V AC @ 0.050A 4 to 20mA 230V AC @ 0.025A 0 to 5V, 0 to 10V 115V AC @ 0.020A 0 to 5V, 0 to 10V 230V AC @ 0.010A 450T AC-Powered (4-wire) Transmitter IN L 450T 3-Way Isolation Special Features Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. Field-selectable input types reduce stocking requirements. Thermocouple reference junction compensation reduces drift and corrects nonlinearity. TC linearizer (5-slope) improves accuracy. TC break detection indicates open circuit failures with selectable up/downscale operation. RFI and EMI resistance minimize the effects of environmental noise. 75% span adjustment enables precise application calibration. S OUT L1 PWR W G 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops. 250T models: Input isolated from output/power. 350T models: Input isolated from output and power. Output and power share a common. 450T models: 3-way isolation. Input, output, and power circuits are isolated from each other. Sense Resistor V/mA PLC / DCS RLOAD Performance Ambient Temperature Range Operating: -13 to 185 F (-25 to 85 C). Storage: -40 to 185 F (-40 to 85 C). Accuracy ±0.1% of calibrated span or ±0.01mV, whichever is greater. Includes repeatability, hysteresis, terminal point linearity, and adjustment resolution. Ambient Temperature Effect Less than ±0.01% of output span per F (±0.018% per C). ±0.025% of output span per F (±0.045% per C) for narrow span units. (Specification includes the combined effects of zero and span over temperature). Noise Resistance RFI: Less than ±0.5%,of output span effect. EMI: Less than ±0.25% of output span effect. Noise Rejection Common Mode: 130dB at 60Hz, 100 ohm unbalance. Normal Mode: 30dB at 60Hz, 100 ohm source. Response Time Output reaches 98% of output span in 300mS. Bandwidth -3dB at 3 Hz, typical. Output Compliance 250T: RLOAD (max.) = (VSUPPLY - 12V) / 20mA. 350T: RLOAD (max.) = (VSUPPLY - 2.5V) / 20mA. 450T: RLOAD = 600 ohms. Linearization (-xlxx) Option 5-segment TC linearizer provides minimum 10 to 1 improvement ±0.1% in the linearity curve. 124

Isolated Transmitters Ordering Information Select one option from each column. Example: 450T-TC3-Y-1-DIN-NCR-C To order factory calibration, append -C to end of model number. Base Input Mounting Approval 250T -TC1 -RL00* -DIN -N4 -NCR -TC3* -SL00* -ST -N12 -OL1 -JL00* -EL00* -SM -XP -DT1 -KL00* -BL00* -EP1 -TL00* -IS1 Base Input Output Mounting Approval 350T -TC1 -RL00* -Y -DIN -NCR -TC3* -SL00* -V0 -JL00* -EL00* -V5 -KL00* -BL00* -TL00* Note: All 250Ts have 4 to 20mA output and are loop-powered. Note: All 350Ts accept 10 to 36V DC power supply. Base Input Output Power Mounting Approval 450T -TC1 -RL00* -Y -1 -DIN -NCR -TC3* -SL00* -V0-2 -JL00* -EL00* -V5 -KL00* -BL00* -TL00* Power Options (450T only) -1: 115V AC power -2: 230V AC power Mounting Options Mountings -DIN: DIN rail G or T mount -ST: SNAPTRACK mount [250T only] -SM: Surface-mount [250T only] External housings -N4: NEMA 4, water-tight [250T only], holds two -N12: NEMA 12, oil-tight [250T only], holds two -XP: Explosion-proof NEMA 4 [250T only], holds one Approval Options -NCR: No certification/approval required. -OL1 : CSA approval, Ordinary Locations [250T only]. -DT1 : CSA approval, Div. 2 hazardous locations: Class I; Div. 2; Groups A, B, C, D [250T only]. -EP1 : CSA approval, Explosion-proof for hazardous locations: Class I; Groups B, C, D Class II; Groups E, F, G. NOTE: Only available with explosion-proof housing (-XP) [250T only]. -IS1 : CSA approval, Intrinsically Safe for hazardous locations: Class I; Groups A, B, C, D. [250T only]. Input Options Nonlinearized Input Options (output linear to millivolts) -TC1: Thermocouple; Field-selectable for J,K,T,R,S,E,B Type J: Span: 100 to 760 C (180 to 1368 F) Zero: -100 to 450 C (-148 to 842 F) Type K: Span: 100 to 1200 C (180 to 2160 F) Zero: -100 to 600 C (-148 to 1112 F) Type T: Span: 150 to 400 C (270 to 720 F) Zero: -150 to 300 C (-238 to 572 F) Type E: Span: 100 to 700 C (180 to 1260 F) Zero: -100 to 350 C (-148 to 662 F) Type R: Span: 550 to 1750 C (990 to 3150 F) Zero: 0 to 1200 C (32 to 2192 F) Type S: Span: 550 to 1750 C (990 to 3150 F) Zero: 0 to 1200 C (32 to 2192 F) Type B: Span: 1000 to 1820 C (1800 to 3276 F) Zero: 0 to 1000 C (32 to 2192 F) -TC3*: Narrow span TC, Field selectable J,K,T,R,S,E,B; (spans from 3 to 5mV );. Linearized Input Options (output linear to temperature for spans over 5mV consult factory for spans under 5mV) -JL00*: Linearized TC for Type J -KL00*: Linearized TC for Type K -TL00*: Linearized TC for Type T -RL00*: Linearized TC for Type R -SL00*: Linearized TC for Type S -EL00*: Linearized TC for Type E -BL00*: Linearized TC for Type B Input Impedance Without TC Break Detection: 1.0M ohm at 10mV span, typical; input current, ±10nA, typical. With TC Break Detection: 400K ohm at 10mV span; input current, ±25nA, typical (±30nA, max.). Output Options (350T, 450T only) -Y: 4 to 20mA DC. -V0: 0 to 10V DC into 10K ohms or greater -V5: 0 to 5V DC into 5K ohms or greater Ordering Notes * Unit requires factory calibration. Append -C to end of model number. Units are shipped separately from any optional enclosures (i.e. units are not installed in any external housing). Units shipped installed in external enclosure. Accessories Power supplies See Power Supplies on page 183. DIN RAIL 3.0 DIN RAIL 16.7 DIN rail strip, Type T, 3 inches (75mm) or 16.7 inches (425mm) 20RM-16-DIN 19" rack-mount kit with DIN rail. Holds sixteen 250T/350Ts or ten 450T transmitters. 350T-N4-WM NEMA 4 water-tight enclosure, wall-mount. Holds two 350Ts or one 450T transmitter. 350T-N12-WM NEMA 12 oil-tight enclosure, wall-mount. Holds two 350Ts or one 450T transmitter. 125

Series Transmitters: 250T, 350T Isolators: 270i, 340i, Limit Alarms: 260A Power Supplies: 25PS, 35PS-2U Surface Mount: 250T-SM, 260A-SM, 270i-SM, 25PS-SM Snaptrack Mount: 250T-ST, 260A-ST, 270i-ST, 25PS-ST 138

Signal Conditioners Explosion-Proof and Industrial Housing 250T-XP, 260A-IH/IHW, 270i-XP 250T Transmitter shown installed in enclosure with cover removed. 250T Transmitter shown removed from enclosure. NEMA-4 and NEMA-12 Enclosures 250T-N4 / N12, 25PS-N4 / N12 260A-N4 / N12, 270i-N4 / N12 139

Series Transmitters: 450T Isolators: 330i, 430i, Limit Alarms: 361A, 461A Power Supplies: 35PS-8U NEMA-4 and NEMA-12 Enclosures 350T-N4-WM 350T-N12-WM 140

Signal Conditioners 20RM-16-DIN Rack Mount Kit AC Sensor 5020-350 141