C series Product brief

Similar documents
Introduction DIN rail mounted electricity meters

MID energy meter B21 Single-phase energy meter, 65 A

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

DELTAplus. DIN Rail Mounted electricity meters. Technical Documentation

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110

Energy Management Energy Meter GM3D

08/07/2015

Electronic timer CT-SDD.22

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

High precision measurement system for current and voltage IHC-A/B-RM01/03

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDS.22

Type CP-S, CP-C & CP-A Switch mode

02/11/2015

05/09/2012

Electronic timer CT-TGD.22

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

08/07/2015

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Overcurrent Protection / 7SJ45

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

02/11/2015

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

02/11/2015

Three-phase monitoring relays

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

83 Series - Modular timers 16 A. Features

7E Series - Energy meter. Features PTB 1

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

02/11/2015

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RS Pro ENGLISH. Datasheet

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Protection components

Paperless Recorder PR20

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relay

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

PART NUMBERING SYSTEM

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Energy Management Energy Meter GM3T E GM3T-RS485 E

Analog signal converters CC-E I/I

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Multi-voltage Multi-function. Wiring diagram (without control signal)

02/11/2015

Energy Management Energy Analyzer Type EM210 MID

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Energy Meter Type EM340

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

CP-T range Product group picture

02/11/2015

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

02/11/2015

Transcription:

Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1 DIN (single phase) or 3 DIN (three phase) modules width Wide temperature range Easy configuration pprovals MID type approval annex B MID initial verification annex F IEC type approval /30 2CMC81003C0201 EQ meters

Description The EQ meters, C series are truly compact meters for single phase and three phase metering. The C series is mounted on a DIN rail and is suitable for installation in distribution boards and small consumer units. General features The C series is a very compact meter only one module wide for single phase and three modules for three phase applications. The meters have an LCD with large digits showing energy register and instrumentation values. The meters have a wide temperature range which makes it possible to install the meters in many locations. Navigating the meters are easily done via the push-button below the display. Instrumentation The C series meters support reading of instrument values. number of electrical properties can be read: Outputs The C series meters have an output that can be used as pulse output or alarm output. The alarm quantity and levels is easily configured on the meter with the push button. The output can be used for controlling external apparatus like a contactor or an alarm indicator (connected via an external relay). pprovals The C series meters are type approved according to IEC and MID. MID is the Measuring Instruments Directive 200/22/EC from the European Commission. The type approval is according to standards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy. MID versions have initial verification according to annex F of the Measuring Instruments Directive. Power factor ctive power Current Voltage EQ meters 2CMC81003C0201 /31

and Single and three phase meter 0 Description Direct connected electricity meter. IEC approval. Instrument values. larm function. Optional - Verified and approved according to MID, 1 DIN. 2CMC86001F0001 Ordering details Voltage V ccuracy Class I/O Type Order Code Pkg qty Weight 1 pc Steel ctive energy 1 x 230 V C Class B (Cl. 1) Pulse output - 110-100 *) 2CM10001R1000 1 0.07 Class 1 110-300 2CM170550R1000 1 0.07 * ) MID approval Description Direct connected electricity meter. IEC approval. 3 element metering. Instrument values. larm function. Optional - Verified and approved according to MID. 2CMC8600F0001 Ordering details Voltage V ccuracy Class I/O Type Order Code Pkg qty Weight 1 pc Steel ctive energy 3 x 230/00 Class B (Cl. 1) Pulse output - 110-100* ) 2CM100191R1000 1 0.17 V C Class 1-110 - 300 2CM100192R1000 1 0.17 * ) MID approval Dimensions 9 89 122 122 9 89 105 111 17,5 58 65 5 5 58 65 /32 2CMC81003C0201 EQ meters

Technical data Voltage/current inputs Nominal voltage 230 V C 3x230/00 Voltage range 230 V C (-20% - +15%) 3x220-20 V C (-20% - +15%) Power dissipation voltage circuits < 0.8 V (0.2 W) total 1.5 V (0.6 W) total Power dissipation current circuits 0.02 W at 230 V C and I b 0.0 V (0.0 W) per phase at 230 V C and I b Base current I b 5 Rated current I n - Reference current I ref 5 Transitional current I tr 0.5 Maximum current I max 0 Minimum current I min 0.25 Starting current I st < 20 m Terminal wire area 1-10 mm 2 0.5-10 mm 2 Recommended tightening torque 0,8 Nm General data Frequency 50 or 60 Hz ± 5% ccuracy Class B (Cl.1) ctive energy 1% Display of energy 6 digits LCD Terminal wire area - Recommended tightening torque - Pulse indicator (LED) Pulse frequency 1000 imp/kwh Pulse length 0 ms Environmental Operating temperature - 25 C - +70 C Storage temperature - 25 C - +85 C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960 C, cover 650 C (IEC 60695-2-1) Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529. Mechanical environment Class M2 in accordance with the Measuring Instrument Directive (MID). (200/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (200/22/EC). Outputs Current 2-100 m Voltage 5-0 V DC Pulse output frequency 100 (imp/kwh) Pulse length 200 ms Terminal wire area 0.5-6 mm 2 Recommended tightening torque 0.8 Nm EMC compatibility Impulse voltage test 6 kv 1.2/50 µs (IEC 60060-1) Surge voltage test kv 1.2/50 µs (IEC 61000--5) Fast transient burst test kv (IEC 61000--) Immunity to electromagneti HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000--3) Immunity to conducted disturbance 150 khz - 80 MHz, (IEC 61000--6) Immunity to disturbance with harmonics 2kHz - 150kHz Radio frequency emission EN 55022, class B (CISPR22) Electrostatic discharge 15 kv (IEC 61000--2) Standards IEC 62052-11, IEC 62053-21 class 1, GBT 17215.211-2006, GBT 17215.321-2008 class 1, GB 208-2008, EN 5070-1, EN 5070-3 category B Mechanical Material Glass reinforced polycarbonate Dimensions Width 17,5 mm 5 mm Height 111 mm 122 mm Depth 65 mm 65 mm DIN modules 1 3 EQ meters 2CMC81003C0201 /33

Wiring diagrams 1 3 6 1 3 Phase in Phase out Terminal blocks 1 3 6 6 Neutral L N 1 7 1 7 Phase in 1 3 6 7 9 10 12 3 6 9 10 12 Phase out Neutral L1 L2 L3 N 3 6 10 12 9 Output = Please see the pictures on the left 20 21 External power supply needed 5-0 VDC... /3 2CMC81003C0201 EQ meters