Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Similar documents
Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Power Rail

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Connection. Composition

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Connection. Thermocouple. Output (4 ma ma) Power supply Power Rail. Composition

Assembly. Front view. HiC2441. SL2 1b. Termination Board

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Inductive sensor slot-type SI2-K08-AP7

Assembly. Front view. Parametrization interface. Power Bus

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Binary Output Series 9175

Technical Data. General specifications. Rated operating distance s n 3 mm

... for hydraulic and general applications in hazardous areas

Digital I/O Coupler (4-wire) Series 9413/21

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

Isolators A3/1. Vibration Transducer Supply Unit Series

Operating Instructions

Temperature Transmitter itemp RTD DIN rail TMT 127

Isolating Repeater Input Series 9163

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Technical Information Barrier RB223

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Level Limit Switch nivotester FTL 370, FTL 372

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Positioner with HART Communication Type 3780

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

SINEAX B 811 Power Pack with additional Functions

Operating Instructions

Level Limit Switch nivotester FTL 325 P

SBEx-2S BINARY SEPARATOR

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators A3/1.

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Binary Output without Power Supply Series 9176

KFS. Flap-type flow meter. Design and range of application

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

Remote Switching Unit nivotester FTL 320

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

2002 IS Catalog. Page

Datasheet ACT20M Signal Isolation and Conversion NEW

RMA42. Technical Information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

SALES SERVICE +358 (0)

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Level Measurement silometer FMX 570

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Electrical Alarm Contacts

K AS-Interface. K Test input

Digital Input Output Module for Zone 2 Series 9470/33

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Rail mounted Temperature Transmitter TH102/TH102-Ex

Digital Input Output Module for Zone 1 Series 9470/32

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Electrical Alarm Contacts

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Temperature transmitter itemp PCP DIN rail TMT 121

Type Nominal voltage (V) Code HSV V

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Analog Universal Module HART for Zone 2 Series 9468/33

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Isolators A3/1.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

Technical Information Nivector FTC968, FTC968Z

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

PRetrans Table of contents

Design and applications

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Single-Channel Safety Barriers Series 9001

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Remote I/O. 74 Remote I/O. Remote I/O System

Digital Input Output Module for Zone 2 Series 9470/33

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Transcription:

solated switch amplifier Output: relay Connection Control circuit EEx ia C 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short-circuit LK and interruption LB) with LED indicator (red flashing), switching output and signal on Power Rail 50 % less wiring 2:1 2 relay outputs, 1 NO contact per channel, grouped into single-pole pairs EMC acc. to NAMUR NE 21 2-channel Function The transformer isolated barrier transfers digital signals from the hazardous area. The inputs are designed for the connection of NAMUR sensors (alternating polarity) per EN 60947-5-6 or a mechanical contact. The input, output and power supply are galvanically isolated from each other. The relay output and the power supply are galvanically isolated from each other per EC 61140 with a rated insulation voltage of 50 V eff. Application nput nput EEx ia C yellow LB SC nput - + - + A A S2 S6 Composition B R 2 R 1 R 1 R 2 B A 2+ 2+ B A 2+ B red S5 S1 7 8 9 Output Output 2:1 Mode Switch S2 in position Resistor for LB and SC: R 1 = 400 Ω R 2 kω R 2 = 10 kω Switch S2 in position + - + - 14+ 15- Power Power LB-collective supply rail error message 1 Safe area Hazardous area Min/Max manometer, valve positioners, magnetic immersion probes with 2 switch points. Two signals can be monitored through one dual lead in the 2:1 mode of operation (AC), reducing wiring by 50 %. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 1

Supply Connection Power Rail or terminals 14+, 15- Rated voltage 20... 30 V DC Ripple 10 % Rated current 45... 70 ma Power loss approx. 1.26 W nput Connection terminals 1-, 2+, 3- Rated values acc. to EN 60947-5-6 (NAMUR), see system description for electrical data Open-circuit voltage/short-circuit current approx. 8 V DC / approx. 8 ma Switching point/switching hysteresis 1.2... 2.1 ma / approx. 0.2 ma Pulse/Pause ratio 20 ms / 20 ms Lead monitoring breakage 0.15 ma Output Connection output : terminals 7, 8 ; output : terminals 8, 9 Collective error message Power Rail Output and signal / ; relay Contact loading 253 V AC / 2 A / cos φ > 0.7; 40 V DC / 2 A resistive load; Energized/de-energized delay Mechanical life Transfer characteristics Switching frequency Electrical isolation nput/output approx. 20 ms / approx. 20 ms 5 x 10 6 switching cycles 10 Hz (non-ac operation) 3 Hz (AC operation) safe electrical isolation acc. to EN 50020, voltage peak value 375 V nput/power supply safe electrical isolation acc. to EN 50020, voltage peak value 375 V Output/power supply basic insulation acc. to DN EN 50178, rated insulation voltage 50 V eff AC Directive conformity Electromagnetic compatibility Directive 89/336/EC EN 61326 Conformity nsulation coordination EN 50178 Electrical isolation EN 50178 Electromagnetic compatibility NE 21 Protection degree EC 60529 nput EN 60947-5-6 Ambient conditions Ambient -20... 60 C (253... 333 K) Mechanical specifications Protection degree P20 Mass approx. 150 g Dimensions 20 x 119 x 115 mm (0.8 x 4.6 x 4.5 in) Data for application in conjunction with hazardous areas EC-Type Examination Certificate ZELM 99 ATEX 0009 Group, category, type of protection (1)G [EEx ia] C Voltage U o 10 V Current o 14 ma Power P o 35 mw (linear characteristic) Supply Safety maximum voltage U m 40 V DC Type of protection [EEx ia] Explosion group C capacitance 3 µf inductance 180 mh Electrical isolation nput/output safe electrical isolation acc. to EN 50020, voltage peak value 375 V Directive conformity Directive 94/9 EC EN 50014, EN 50020 General information Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity and instructions have to be observed. For information see www.pepperl-fuchs.com. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 2

Notes Accessories Power feed modules KFD2-EB2... The power feed module is used to supply the devices with 24 V DC via the Power Rail. The fuse-protected power feed module can supply up to one hundred individual devices depending on the power consumption of the devices. A galvanically isolated mechanical contact uses the Power Rail to transmit collective error messages. Power Rail UPR-03 The Power Rail UPR-03 is a complete unit consisting of the electrical inset and an aluminium profile rail 35 mm x 15 mm. To make electrical contact, the devices are simply engaged. The Power Rail must not be fed via the device terminals of the individual devices! s (field installation) F-KD-Ex2 () and F-KDR-Ex2 ( and resistor) The transformer isolated barrier transfers binary signals from the hazardous area by means of the patented new 2:1-transfer method. This method allows to transfer two independent binary signals by means of a single pair of conductors. The prerequisite for the use of the 2:1-transfer method is that sensors with reverse polarity protected are used. Pepperl+Fuchs offers suitable sensors for alternating polarity (see table). When using sensors without integrated reverse polarity protection, external s F-KD-Ex2 have to be fitted.n case of F-KDR-Ex2, a resistor combination has been fitted in addition for cable error detection of mechanical switches. Comments: When installing a serial, it has to be assured that the current in reverse direction is below a value of 0.15 ma in order to enable the lead monitoring. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 3

Functions of the switch Lead breakage and short circuit monitoring nput 10 kω 1 kω with lead breakage and short circuit monitoring without lead breakage and short circuit monitoring AC function nput - + - + 1 3 - + - + 1 3 AC function (2:1 transfer technique) 1-2+ 1-2+ none AC function 2+ 3-2+ 3- Mode of operation nput 1 signal S3: channel V S4: channel S5: channel S6: channel 0 signal energised de-energised 0 signal energised S3: channel V S4: channel S5: channel S6: channel 1 signal de-energised Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 4

Pepperl+Fuchs sensors for alternating polarity FJ 6-110-F yes -25 C... 100 C NCB2-12GM35-NO 5M no -25 C... 70 C FJ 7-N yes -25 C... 100 C NCB2-12GM35-NO-V1 no -25 C... 70 C NCB1,5-6,5M25-NO no -25 C... 70 C NCB5-18GM4O-NO no -25 C... 70 C NCB1,5-6,5M25-NO-V1 no -25 C... 70 C NCB5-18GM4O-NO 1OM no -25 C... 70 C NCB1,5-8GM25-NO no -25 C... 70 C NCB5-18GM4O-NO 5M no -25 C... 70 C NCB1,5-8GM25-NO 1OM no -25 C... 70 C NCB5-18GM4O-NO-V1 no -25 C... 70 C NCB1,5-8GM25-NO 5M no -25 C... 70 C NCB10-30GM40-N0 no -25 C... 70 C NCB1,5-8GM25-NO-V1 no -25 C... 70 C NCB10-30GM40-N0-V1 no -25 C... 70 C NCB2-12GM35-NO no -25 C... 70 C NCB15+U1+N0 no -25 C... 70 C NCB2-12GM35-NO 1OM no -25 C... 70 C NCN15-30GM40-N0 no -25 C... 70 C NCN15-30GM40-N0-V1 no -25 C... 70 C NJ 2-N-H42 yes -25 C... 100 C NCN15-M1K-N0 no -25 C... 70 C NJ 2-V3-N yes -25 C... 100 C NCN20+U1+N0 no -25 C... 70 C NJ 2-V3-N-V5 yes -25 C... 100 C NCN30+U1+N0 no -25 C... 70 C NJ 3-18GK-S1N no -25 C... 100 C NCN3-F24L-N4 no -25 C... 70 C NJ 4-12GK-N no -25 C... 100 C NCN3-F24R-N4 no -25 C... 70 C NJ 4-12GK-N 10M no -25 C... 100 C NCN3-F25F-N4-V1 no -25 C... 70 C NJ 4-12GK-N 5M no -25 C... 100 C NCN3-F25-N4-014 no -25 C... 70 C NJ 4-12GM-N no -25 C... 100 C NCN3-F25-N4-075 no -25 C... 70 C NJ 4-12GM-N 10M KA no -25 C... 100 C NCN3-F25-N4-V1 no -25 C... 70 C NJ 4-12GM-N 15M no -25 C... 100 C NCN3-F31-N4-K no -25 C... 70 C NJ 4-12GM-N 20M no -25 C... 100 C NCN3-F31-N4-K-K no -25 C... 70 C NJ 4-12GM-N 5M no -25 C... 100 C NCN3-F31-N4-V16-V16 no -25 C... 70 C NJ 4-12GM-N-V1 no -25 C... 100 C NCN3-F31-N4-V18 no -25 C... 70 C NJ 4-F-N yes -25 C... 100 C NCN40+U1+N0 no -25 C... 70 C NJ 4-N-H31 yes -25 C... 100 C NCN4-12GM35-NO no -25 C... 70 C NJ 5-11-N no -25 C... 100 C NCN4-12GM35-NO 1OM no -25 C... 70 C NJ 5-11-N 15M KA. no -25 C... 100 C NCN4-12GM35-NO 5M no -25 C... 70 C NJ 5-11-N 5M KA. no -25 C... 100 C NCN4-12GM35-NO-V1 no -25 C... 70 C NJ 5-11-N-G no -25 C... 100 C NCN4-M3K-N4 no -25 C... 70 C NJ 5-11-N-G 10M KA. no -25 C... 100 C NCN8-18GM4O-NO no -25 C... 70 C NJ 5-11-N-G 5M KA. no -25 C... 100 C NCN8-18GM4O-NO 5M no -25 C... 70 C NJ 5-11-N-G 6M no -25 C... 100 C NCN8-18GM4O-NO-V1 no -25 C... 70 C NJ 5-18GK-N no -25 C... 100 C NJ 0,8-4,5-N no -25 C... 100 C NJ 5-18GK-N 10M KA no -25 C... 100 C NJ 0,8-5GM-N no -25 C... 100 C NJ 5-18GK-N 5M KA. no -25 C... 100 C NJ 0,8-5GM-N 5M no -25 C... 100 C NJ 5-18GK-SN yes -25 C... 100 C NJ 0,8-5GM-N 10M no -25 C... 100 C NJ 5-18GK-SN 5M KA. yes -25 C... 100 C NJ 0,8-F-N yes -25 C... 100 C NJ 5-18GK-SN 10M yes -25 C... 100 C NJ 1,5-6,5-N no -25 C... 100 C NJ 5-18GM-N no -25 C... 100 C NJ 1,5-6,5-N 15M no -25 C... 100 C NJ 5-18GM-N 10M KA no -25 C... 100 C NJ 1,5-6,5-N 5M no -25 C... 100 C NJ 5-18GM-N 5M KA. no -25 C... 100 C NJ 1,5-8GM-N no -25 C... 100 C NJ 5-18GM-N-V1 no -25 C... 100 C NJ 1,5-8GM-N 10M no -25 C... 100 C NJ 5-30GK-S1N yes -25 C... 100 C NJ 1,5-8GM-N 5M no -25 C... 100 C NJ 5-30GK-S1N 10M yes -25 C... 100 C NJ 1,5-8GM-N-V1 no -25 C... 100 C NJ 5-30GK-S1N 5M yes -25 C... 100 C NJ 1,5-F-N yes -25 C... 100 C NJ 6-22-SN yes -25 C... 100 C NJ 1-N2-G 82 yes -25 C... 100 C NJ 6-22-SN 10M yes -25 C... 100 C NJ 1-N-728 no -25 C... 70 C NJ 6-22-SN-G yes -25 C... 100 C NJ 2,5-F-N yes -25 C... 100 C NJ 6-22-SN-G 10M yes -25 C... 100 C NJ 2-11-N no -25 C... 100 C NJ 6-22-SN-G 3M yes -25 C... 100 C NJ 2-11-N 5M no -25 C... 100 C NJ 6-F-N yes -25 C... 100 C NJ 2-11-N-G no -25 C... 100 C NJ 6S1+U1+N1 yes -25 C... 100 C NJ 2-11-N-G 15M no -25 C... 100 C NJ 8-18GK-N no -25 C... 100 C NJ 2-11-N-G 5M no -25 C... 100 C NJ 8-18GK-N 10M KA. no -25 C... 100 C Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 5

NJ 2-11-SN yes -25 C... 100 C NJ 8-18GM-N no -25 C... 100 C NJ 2-11-SN yes -25 C... 100 C NJ 8-18GM-N 5M no -25 C... 100 C NJ 2-11-SN-G yes -25 C... 100 C NJ 8-18GM-N-V1 no -25 C... 100 C NJ 2-11-SN-G 10M yes -25 C... 100 C NJ 10-F-N yes -25 C... 100 C NJ 2-11-SN-G 5M yes -25 C... 100 C NJ 15+U1+N yes -25 C... 100 C NJ 2-12GK-N no -25 C... 100 C NJ 15-M1K-N yes -25 C... 100 C NJ 2-12GK-N 5M no -25 C... 100 C NJ 15-M1-N yes -25 C... 100 C NJ 2-12GM-N no -25 C... 100 C NJ 15-M1-N-V yes -25 C... 100 C NJ 2-12GM-N 10M no -25 C... 100 C NJ 15S+U1+N yes -25 C... 100 C NJ 2-12GM-N 21M no -25 C... 100 C NJ 20+U1+N yes -25 C... 100 C NJ 2-12GM-N 5M no -25 C... 100 C NJ 20S+U1+N yes -25 C... 100 C NJ 2-12GM-N-V1 no -25 C... 100 C NJ 30+U1+N yes -25 C... 100 C NJ 2-F1-N yes -25 C... 100 C NJ 30P+U1+1N yes -25 C... 100 C NJ 40+U1+N yes -25 C... 100 C SJ 2-SN XM KA yes -25 C... 100 C RJ 10-14-N yes -25 C... 100 C SJ 3,5-G-N no -25 C... 100 C RJ 10-N yes -25 C... 100 C SJ 3,5-N no -25 C... 100 C RJ 15-14-N yes -25 C... 100 C SJ 3,5-N BLAU no -25 C... 100 C RJ 15-N yes -25 C... 100 C SJ 3,5-N GELB no -25 C... 100 C RJ 21-N yes -25 C... 100 C SJ 3,5-N GRÜN no -25 C... 100 C RJ 43-N yes -25 C... 100 C SJ 3,5-N LED yes -25 C... 100 C SC2-N0 no -25 C... 100 C SJ 3,5-N WESS no -25 C... 100 C SC3,5-N0 no -25 C... 100 C SJ 3,5-S1N yes -25 C... 100 C SC3,5-N0 BLAU no -25 C... 100 C SJ 3,5-SN yes -25 C... 100 C SC3,5-N0 GELB no -25 C... 100 C SJ 5 MT LÖTSTFTEN yes -25 C... 100 C SC3,5-N0 GRÜN no -25 C... 100 C SJ 5-G-N yes -25 C... 100 C SC3,5-N0 WEß no -25 C... 100 C SJ 5-K-N yes -25 C... 100 C SJ 2-N no -25 C... 100 C SJ 5-N yes -25 C... 100 C SJ 2-N 5M KA no -25 C... 100 C SJ 10-N yes -25 C... 100 C SJ 2-SN yes -25 C... 100 C SJ 15-N yes -25 C... 100 C Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 nternet www.pepperl-fuchs.com 6