Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

Similar documents
Voltage Sag and Mitigation Using Algorithm for Dynamic Voltage Restorer by PQR Transformation Theory

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Review Power Quality Issues

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Power Quality Improvement using Hysteresis Voltage Control of DVR

Power Quality enhancement of a distribution line with DSTATCOM

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Simulation and Implementation of DVR for Voltage Sag Compensation

ISSN Vol.07,Issue.21, December-2015, Pages:

Design Requirements for a Dynamic Series Compensator for Voltage Sags Mitigation in Low Voltage Distribution System

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Ghazanfar Shahgholian *, Reza Askari. Electrical Engineering Department, Najafabad Branch, Islamic Azad University, Isfahan, Iran

Compensation of Different Types of Voltage Sags in Low Voltage Distribution System Using Dynamic Voltage Restorer

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Protection from Voltage Sags and Swells by Using FACTS Controller

IMPROVEMENT OF VOLTAGE SAG MITIGATION USING DYNAMIC VOLTAGE RESTORER (DVR)

Volume I Issue VI 2012 September-2012 ISSN

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

World Journal of Engineering Research and Technology WJERT

II. RESEARCH METHODOLOGY

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

Study & Comparison of Various Topologies of Dynamic Voltage Restorer & Its type: a Review

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

ISSN Vol.03,Issue.11, December-2015, Pages:

Power Quality Improvement in Distribution System Using D-STATCOM

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Power Quality and the Need for Compensation

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Mitigation of voltage sags/swells unbalanced in low voltage distribution systems

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Auxiliary DC Voltage

A Power Control Scheme for UPQC for Power Quality Improvement

A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage Restorer with Sag & Swell Limiting Function

VOLTAGE SAG COMPENSATION USING UNIFIED POWER FLOWER CONTROLLER IN MV POWER SYSTEM USING FUZZY CONTROLLER

A REVIEW PAPER ON REGULATION TECHNIQUE FOR VOLTAGE SAG AND SWELL USING DVR

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

A Voltage Controlled Dstatcom for Power Quality Improvement

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

A Review on Improvement of Power Quality using D-STATCOM

p. 1 p. 6 p. 22 p. 46 p. 58

Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI)Controller for Mitigation of Voltage Sag

Modelling of Dynamic Voltage Restorer for Mitigation of Voltage Sag and Swell Using Phase Locked Loop

Power Control Scheme of D-Statcom

Improvement in Power Quality of Distribution System Using STATCOM

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

VOLTAGE SAG MITIGATION USING A NEW DIRECT CONTROL IN D-STATCOM FOR DISTRIBUTION SYSTEMS

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

A Five Level DSTATCOM for Compensation of Reactive Power and Harmonics

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

OVERVIEW OF DVR FOR POWER QUALITY IMPROVEMENT

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Performance of DVR & Distribution STATCOM in Power Systems

International Journal of Scientific & Engineering Research, Volume 6, Issue 8, August ISSN

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

SIMULATION OF D-STATCOM IN POWER SYSTEM

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

QUESTION BANK PART - A

Performance of DVR under various Fault conditions in Electrical Distribution System

Compensation of Unbalanced Sags/Swells by Single Phase Dynamic Voltage Restorer

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

DYNAMIC VOLTAGE RESTORER FOR VOLTAGE SAG MITIGATION IN OIL & GAS INDUSTRY

MITIGATION OF VOLTAGE SAG IN A DFIG BASED WIND TURBINE USING DVR

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

PQ Monitoring Standards

SUPERCONDUCTING MAGNETIC ENERGY

Modeling and Simulation of STATCOM

Voltage Correction Methods in Distribution System Using DVR

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

Investigation of Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

Transcription:

Faculty of Electrical Engineering Universiti Teknologi Malaysia OL. 8, NO., 006, 3 37 ELEKTRIKA oltage Sag and Mitigation Using Dynamic oltage Restorer (DR) System Shairul Wizmar Wahab and Alias Mohd Yusof * Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia. * Corresponding author: aliasm@fke.utm.my (Alias Mohd Yusof), Tel: 607-553540, Fax: 607-55667. Abstract: This paper highlights voltage sag as one of a power quality issue and Dynamic oltage Restorer (DR) is using for mitigation of voltage sag. oltage sag is short reduction voltage from nominal voltage, occurs in a short time which can cause damage and loss of production especially in industrial sector. oltage sag always related with short circuit events and starting motor which draw very high lagging current. Since voltage sag is creating worse effects, the researchers almost keen to find the solutions for this problem. Nowadays, a lot of devices have been developed to mitigate voltage sag such as Dynamic oltage Restorer (DR), Distribution Static Compensator (D-Statcom) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DR system which will be simulated by using PSCAD software in order to mitigate voltage sag. Mathematics model for calculation of voltage sag and voltage injection by DR System also described. Keywords: Dynamic voltage restorer, PSCAD software, oltage sag. 1. INTRODUCTION In many recent years, power quality disturbances become most issue which makes many researchers interested to find the best solutions to solve it. There are various types of power quality which are transients, short duration voltage variation, long duration voltage variation, voltage imbalance, waveform distortion and voltage flicker. Under short duration voltage variation, there re voltage sag, voltage swell and interruption. Based on records by Tenaga Nasional Berhad (TNB), 80% of power quality complaints in Malaysia were traced to be related to voltage sag [1]. Due to the increasing of new technology, a lot of devices had been created and developed for mitigation of voltage sag. This paper concerns two objectives of this project which are study on voltage sag phenomenon in power system and mitigation this phenomenon by using Dynamic oltage Restorer (DR) system. A scope of project is DR system will be simulate by using power system software, PSCAD/EMTDC 4. In order to carry out these objectives successfully, voltage sag characteristics and DR system will be discussing theoretically in details. Simulations are divided to three parts which are performance of DR system, the effects of voltage sag caused by fault in power system connected with DR system, and finally increasing performance of DR system.. OLTAGE SAG oltage sag is widely recognized as one of the most important power quality disturbances [1]. oltage sag (Figure 1) is a short reduction in rms voltage from nominal voltage, happened in a short duration, about 10ms to seconds. The IEC 61000-4-30 defines the voltage sag (dip) as a temporary reduction of the voltage at a point of the electrical system below a threshold []. According to IEEE Standard 1159-1995, defines voltage sags as an rms variation with a magnitude between 10% and 90% of nominal voltage and duration between 0.5cycles and one minute[5]. Figure 1. oltage sag waveform oltage sag is happened at the adjacent feeder with unhealthy feeder (Figure ). This unhealthy feeder always caused by two factors which are short circuits due to faults in power system networks and starting motor which draw very high lagging current. Both of these factors are the main factor creating voltage sag as power quality problem in power system. oltage sags are the most common power disturbance which certainly gives affecting especially in industrial and large commercial customers such as the damage of the sensitivity equipments and loss of daily productions and finances. An example of the sensitivity equipments are programmable logic controller (PLC), adjustable speed drive (ASD) and chiller control. There are many ways in order to mitigate voltage sag problem. One of them is minimizing short circuits caused by utility directly which can be done such as with avoid feeder or cable overloading by correct configuration 3

SHAIRUL WIZMAR WAHAB, ALIAS MOHD YUSOF / ELEKTRIKA, 8(), 006, 3 37 planning. Another alternative is using the flexible ac technology (FACTS) devices which have been used widely in power system nowadays because of the reliability to maintain power quality condition includes for voltage sag mitigation.. There are many devices have been created with purpose to enhance power quality such as Dynamic oltage Restorer (DR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). All of these devices are also known as custom power devices. Figure 3. DR Structure Figure. oltage sag phenomenon 3. DR SYSTEM Dynamic voltage restorer (DR) is a series compensator which is able to protect a sensitive load from the distortion in the supply side during fault or overloaded in power system. The basic principle of a series compensator is simple, by inserting a voltage of required magnitude and frequency, the series compensator can restore the load side voltage to the desired amplitude and waveform even when the source voltage is unbalanced or distorted [3].This DR device employs gate turn off thyristor (GTO) solid state power electronic switches in a pulse width modulated (PWM) inverter structure. The DR can generate or absorb independently controllable real and reactive power at the load side. The DR also is made of a solid state dc to ac switching power converter that injects a set of three phase ac output voltages in series and synchronism with the distribution feeder voltages [3]. The amplitude and phase angle of the injected voltages are variable thereby allowing control of the real and reactive power exchange between the DR and the distribution system [3]. The dc input terminal of a DR is connected to an energy source or an energy storage device of appropriate capacity. The reactive power exchange between the DR and the distribution system is internally generated by the DR without ac passive reactive components. The real power exchanged at the DR output ac terminals is provided by the DR input dc terminal by an external energy source or energy storage system. DR structure comprises rectifier, inverter, filter and coupling transformer (Figure 3). Besides, pulse width modulated (PWM) technique is using to control variable voltage. Filter is using for elimination harmonic generated from high switching frequency in PWM technique. In power system network, DR system is connected in series with the distribution feeder that supplies a sensitive load (Figure 4). Figure 4. DR system in power system 4. THE PRINCIPLE OPERATION OF DR SYSTEM In normal situation without short circuit in power system, a capacitor between rectifier and inverter (Figure 3) will be charging. When voltage sag happened, this capacitor will discharge to maintain load voltage supply. Nominal voltage will be compared with voltage sag in order to get a difference voltage that will be injected by DR system to maintain load voltage supply. PWM technique is using to control this variable voltage. In order to maintain load voltage supply, reactive power must be injected by DR system. Practically, the capability of injection voltage by DR system is 50% of nominal voltage. It is sufficient for mitigation voltage sag because from statistic shown that many voltage sag cases in power system involving less than 0.5 p.u. voltage drop. 5. MATHEMATICS MODEL FOR OLTAGE SAG CALCULATION Considered Figure 5, in a normal condition (no fault), current through load A and load B is equal (balance load).when there s fault on feeder 1, a high current (short circuit current) will flow to feeder 1. So, based on Kirchhoff s Law, currents flow to feeder will be reduced. Consequently, voltage will also drop in feeder.this voltage drop will be defined as voltage sags. Assume Load A = Z LOAD_A Load B = Z LOAD_BB Feeder 1 Reactance = x 1 Feeder Reactance = x Current from supply source = I Current in feeder 1 = I 1 Current in feeder = I 33

SHAIRUL WIZMAR WAHAB, ALIAS MOHD YUSOF / ELEKTRIKA, 8(), 006, 3 37 Thus I = I 1 + I In normal condition (without fault in system) I = x + Z LOAD _ B + x + Z 1 LOAD _ A When a fault happened (see Figure 5) in feeder 1, because of short circuit, a high current will flow through feeder 1 as well as source current I. During this time, voltage in feeder decreased due to increasing of voltage drop across source reactance x s, this makes sag happened. I = x + Z LOAD _ B + x 1 (1) (when fault happened) () When L is considered as a reference, therefore; ( β θ ) δ α = 0 + Z I (8) DR L Here α, β and δ are the angle of DR, Z th and th, respectively and θ is the load power factor angle with 1 QL θ = tan. PL The power injection of the DR can be written as S DR = th L DR I L (9) th Hence = s Ix s (3) and decreased from nominal value ( become as voltage sag) Figure 6. Calculation for DR voltage injection 7. RESULTS AND DISCUSSION With using PSCAD software, simulations are divided into five parts in order to study the characteristics and the performance of DR system to mitigate voltage sag. Figure 5. Calculation for voltage sag 6. MATHEMATICS MODEL FOR OLTAGE INJECTION BY DR SYSTEM Consider the schematic diagram shown in Figure 6. Z th = R th + jx th (4) DR + th = L + Z th I L (5) When dropped voltage happened at L, DR will inject a series voltage DR through the injection transformer so that the desired load voltage magnitude L can be maintained. Hence DR = L + Z th I L th (6) 7.1 Performance of DR System-ariable oltage of Supply This part of simulation was done in order to study the performance of DR system in boosting the drop voltage caused by sag voltage. Refer to IEC standard, the voltage range is +5% to -10%. Practically, DR has a limitation in boosting the drop voltage. Modeling for simulation in this part can be seeing in Figure 7. Figure 8 shows DR structure and Figure 9 shows firing pulses for controlling DR system. The voltage is varied from 5k to nominal voltage, 11k. From Table 1, we can see DR can provide sufficient voltage (within the power quality requirement) for the drop voltage as low as 0.6p.u. While for the drop voltage below 0.6p.u, DR system still can boost the voltage drop but not enough to achieve to 0.9p.u of nominal voltage as the minimum power quality requirement. It means for a high severity of dropped voltage, DR still can boost that dropped voltage but insufficient to achieve the desired output voltage. PL + jq I L = L L (7) 34

SHAIRUL WIZMAR WAHAB, ALIAS MOHD YUSOF / ELEKTRIKA, 8(), 006, 3 37 Table 1: Data for variable voltage of supply oltage (k) E a (p.u) E b (p.u) 11 0.98747 0.990688 10 0.89951 0.994037 9 0.81003 0.97653 8 0.71931 0.95403 7 0.68609 0.905341 6 0.538808 0.866 5 0.449598 0.810467 Figure 7. Modelling for variable voltage of supply 7. Applying oltage Sags in Power System with DR Three phase fault is created on the network system (Figure 10). Time duration for fault is (0.3-0.5)s and breaker will isolate the unhealthy feeder at 0.5s. The length between the feeders will determine the severity of dropped voltage. For short distance between these feeders, if fault occurred at one feeder, the other feeder will face high severity for dropped voltage. For long distance between these feeders, the severity for dropped voltage is not too high. So, a variable length is set in this simulation to show the severity of dropped voltage during voltage sag phenomenon. Table shows the data taken from the simulation. From previous section that has been discussed (ariable oltage of Supply), DR can only provide sufficient voltage for the 48% severity from nominal voltage. As the conclusion for this simulation, the lengths between these feeders determine the severity of drop voltage and DR will mitigate voltage sag phenomenon. Mitigation voltage sag for this simulation can be observed in Figure 11 and Figure 1. Figure 8. DR structure Figure 10. ariable length for voltage sag Figure 9. Firing pulses for PWM technique 35

SHAIRUL WIZMAR WAHAB, ALIAS MOHD YUSOF / ELEKTRIKA, 8(), 006, 3 37 Figure 11. Waveform of mitigation voltage sag (p.u.) In this simulation, the DC voltage is increased with setting the transformer 1.5MA and secondary voltage is 3k. In doing so, changing the filter to 100uF will produce a better filtration (doubled the value before this) (Refer Figure 8). The result from Table 3 shows that DR can compensate drop voltage as low as 4% of nominal voltage. Compared to the previous DR system (K DC voltage), it enable compensate drop voltage to as low as 6% of nominal voltage only. As the conclusion, with increasing DC voltage, DR performance for compensating the dropped voltage can be increased. Figure 1. Waveform of mitigation voltage sag Table. ariable length for voltage sag Length (km) Ea (p.u) Eb (p.u) 10 0.9581 0.99848 3 0.89686 0.9937 1 0.763966 0.966975 0.75 0.7179 0.95369 0.5 0.65187 0.90331 0.1 0.547569 0.870387 7.3 Increasing Performance of DR System There are two main factors relating to the capability and performance of DR working against voltage sags in a certain power system: the sag severity level and the Total Harmonic Distortion (THD). Both of these in turn are mainly decided by the DC source [4]. Based on previous discussion (ariable oltage of Supply), the DC voltage is coming from the transformer that the setting parameter is 1MA and secondary voltage is k.besides that, the secondary filter at coupling transformer is 50uF. The result shows DR only can compensate voltage for severity 48% from nominal value. It means DR can inject sufficient voltage when the drop voltage is at least 0.6 p.u. There are two ways for increasing DC voltage in DR system. One of them is increasing secondary voltage value and another one is increasing rating MA transformer. Increasing rating MA transformer will draw small dropped voltage from primary to secondary voltage. For better and higher DC result for this simulation, both of this parameter is increased. Figure 13. Increasing performance of DR system Table 3: Data for increasing performance of DR oltage(k) Ea(p.u) Eb(p.u) 11 0.97835 0.993059 5 0.445864 0.936014 4.8 0.48068 0.91069 4.7 0.419155 0.896031 4 0.35688 0.788454 8. CONCLUSION In this paper, a complete simulated DR system has been developed by using the PSCAD software. Its characteristic and performance when applied to a simulated power system has been studied. It is shown that the simulated DR developed, works successfully without lacks in its performance when applied to a simulated power system network. By introducing DR in the power network, it can help to improve power quality. It is important to have a good delivery power quality in electrical power systems especially to the critical areas, such as in the industrial sectors, in order to ensure the smoothness of the daily operations. Hopefully this paper could be a beneficial reference to others who are keen on voltage sag study. 36

SHAIRUL WIZMAR WAHAB, ALIAS MOHD YUSOF / ELEKTRIKA, 8(), 006, 3 37 REFERENCES [1] M. F. Faisal, Power quality management program: TNB s Experience, Distribution Engineering Department, TNB, 005. [] A. Felce, G. Matas, Y. D. Silva, oltage sag analysis and solution for an industrial plant with embedded induction motors, Inelectra S.A.C.A. Caracas, enezuela, 004. [3] A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices, Kluwer Academic Publishers, 00. [4] P. T. Nguyen and T. K. Saha (004), DR against balanced and unbalanced voltage sags: Modeling and simulation, IEEE-School of Information Technology and Electrical Engineering, University of Queesland, Australia, 004. [5] Pirjo Heine, Matti Lehtonen, oltage sag distributions caused by power system faults, IEEE Transactions on Power Systems, ol. 18, No. 4, November 003. 37