VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

Similar documents
Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual. Agilent Technologies June 2012

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

RF Characterization Report

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

Power Supply Rejection Ratio Measurement

Circuit Characterization with the Agilent 8714 VNA

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

Keysight Technologies Amplifier and CW Swept Intermodulation - Distortion Measurements using the PNA Microwave Network Analyzers.

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Limitations And Accuracies Of Time And Frequency Domain Analysis Of Physical Layer Devices

Frequency and Time Domain Representation of Sinusoidal Signals

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

External Source Control

Antenna Measurement using Vector Network Analyzer. Jong-hwan Keum Agilent Technologies

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Configuration of PNA-X, NVNA and X parameters

Impedance 50 (75 connectors via adapters)

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

PXIe Contents CALIBRATION PROCEDURE

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

EXTEND YOUR REACH. Copper Mountain Technologies USB VNAs. S-parameter measurement solutions from 9 khz to 110 GHz Measured parameters from S 11

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Pulsed S-Parameter Measurements using the ZVA network Analyzer

Keysight Technologies PNA-X Series Microwave Network Analyzers

Advanced Test Equipment Rentals ATEC (2832)

QuickSyn Frequency Synthesizers

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

LA Techniques Ltd

Keysight MOI for USB Type-C Connectors & Cable Assemblies Compliance Tests (Type-C to Legacy Cable Assemblies)

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

NI PXIe-5630 Specifications

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

ME1000 RF Circuit Design. Lab 1. Calibration with Spectrum Analyzer

DC/DC Converter Stability Measurement

Equivalent Circuit Determination of Quartz Crystals

Keysight MOI for USB Type-C Connectors & Cable Assemblies Compliance Tests (Type-C to Legacy Cable Assemblies)

Introduction. Part 1. Introduction...2

DC/DC Converter Stability Measurement

Network Analysis Basics

Pulsed Measurement Capability of Copper Mountain Technologies VNAs

Measurement of the equivalent circuit of quartz crystals

Overcoming Mixer Measurement Challenges

Keysight Technologies UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Keysight FieldFox Handheld Analyzers

Analysis of RF transceivers used in automotive

PLANAR S5048 and TR5048

Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.

Vector Network Analyzers T - Series

S3602A/B Vector Network Analyzer Datasheet

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Novel Method for Vector Mixer Characterization and Mixer Test System Vector Error Correction. White Paper

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent ESA-L Series Spectrum Analyzers

Low Value Impedance Measurement using the Voltage / Current Method

Battery Impedance Measurement

Keysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode. Application Note

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

S3602C Vector Network Analyzer Datasheet

Pulsed VNA Measurements:

DC/DC Converter Stability Measurement

Agilent N9320B RF Spectrum Analyzer

Features and Technical Specifications

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

Measuring Power Line Impedance

Fast and Accurate Simultaneous Characterization of Signal Generator Source Match and Absolute Power Using X-Parameters.

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Experiment 03 - Automated Scalar Reectometry Using BenchVue

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method For Coaxial Cable Impedance

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Keysight Technologies Basics of RF Ampliier Measurements with the E5072A ENA Series Network Analyzer

Gain Lab. Image interference during downconversion. Images in Downconversion. Course ECE 684: Microwave Metrology. Lecture Gain and TRL labs

SRT optical links prototypes characterization

Introduction. Part 1. Introduction...2

THE SPECTRUM ANALYZER AND SPECTRAL CONTENT

Vector Network Analyzer TW4600

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Introducing ENA Series E5061B-1x5/2x5/1x7/2x7 RF NA Options 100 khz to 1.5 / 3 GHz

Signal Analysis Measurement Guide

Agilent AN Applying Error Correction to Network Analyzer Measurements

PLANAR 814/1. Vector Network Analyzer

Keysight Technologies In-Fixture Measurements Using Vector Network Analyzers. Application Note

Agilent PNA Microwave Network Analyzers

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

Attenuators, Couplers and Filters

TETRA Tx Test Solution

A True Differential Millimeter Wave System with Port Power Control. Presented by: Suren Singh

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!

Transcription:

VVM measurement with E5061B for replacing 8508A vector voltmeter May 2013 Agilent Technologies

Overview of VVM measurement with E5061B Application discussed here Measuring the phase difference (& magnitude ratio) of external CW signals with 50 Ω inputs in the freq range around 100 to 200 MHz. Measurement method with E5061B Turn the source output OFF (RF OUT OFF). Set the center to exactly the same as DUT s CW, and the span to zero. If possible, lock the reference between the E5061B and DUT. Attach 15 or 20 db attenuator pads to Port-1 & 2. Measure the ratio Port-2/Port-1=S21/S11 using the equation editor. S21/S11 = (T2/R1)/(T1/R1) = T2/T1 ref. lock 15 or 20 db pads DUT E5061B with 50 Ω T/R or S-parameter test ports RF OUT OFF R1 T1 Port-1 T2 Port-2 2

Measurement example Ratio measurement of external 200 MHz CW signals E5061B setting: Center=200 MHz, span=0, NOP=2, IFBW=1 khz, RF OUT: OFF Trigger: Internal continuous Trace-1: LogMag Trace-2: Phase Equation: Ratio=S21/S11 Marker for reading measured result 3

Tips for VVM measurement with E5061B Adding attenuator pads Impedance mismatches between the DUT and the analyzer s test ports are the most significant error sources, especially in case the isolation between the DUT s output ports is not high. To reduce these mismatch errors, it is necessary to improve the raw port matches by adding 15 or 20 db attenuator pads. This is true even for the 8508A. To make a good measurement correlation between the E5061B and 8508A, the attenuator pads should be connected to both analyzers. Port extension Setting a positive or negative port extension to the Port-2 compensates the difference of electrical lengths between two signal paths. Measurement frequency The E5061B s center frequency must be set to exactly the same as the DUT s frequency. If possible, lock the reference between the DUT and the E5061B. If the locking is not possible and the DUT s frequency might be slightly differ from the E5061B s frequency, use a wider IFBW (e.g. 10 khz) to capture the DUT s signal. 4

Effect of attenuator pads and port extension Experimental measurement (1) Measured almost equally divided CW signals (100 MHz to 500 MHz, step). Swept the frequency of the DUT s CW signals, and measured its ratio by synchronizing the E5061B s measurement point by point. Trigger in E5061B Start=100 MHz, Stop=500 MHz, NOP=41, IFBW=1 khz, RF OUT OFF Equation: S21/S11 Trigger : External, on-point Sweep initialized before starting MXG s sweep (by pressing Restart key ). ref. in Port-1 Port-2 Trigger out MXG Freq sweep: 100 M to 500 MHz, 41 points Output level =0 dbm, Point delay 100 ms Sweep started by pressing Single sweep key. ref. out With or without 15 db pads 11636B power divider (3-resistor type, 6 db isolation between output ports) 60 cm SMA cables 5

Phase difference (deg) Effect of attenuator pads and port extension Experimental measurement (1), results The ripples caused by impedance mismatches are reduced by adding 15 db pads to the Port-1 & 2. Setting +7 ps port extension to the Port-2 (applied to the S21 measurement) compensates the difference of electrical lengths between two cables, and the measured phase gets closer to 0 degree up to high frequencies. Ch1: Without pads (1 deg/div) Ch2: With 15 db pads (0.5 deg/div) Ch3: With 15 db pads, 7 ps extension (0.5 deg/div) 5.0 4.0 3.0 2.0 1.0 0.0-1.0-2.0-3.0-4.0-5.0 1.E+08 3.E+08 5.E+08 DUT's output freq (Hz) Without pads With 15 db pads With 15 db pads & 7 ps port extention 100 MHz 500 MHz 6

Measurement accuracy Experimental measurement (2) Measured unequally divided CW signals by adding a 10 cm cable only to the Port-2 path. +7 ps port extension applied to the Port-2. Compared with the S31/S21 measurement using the full 3-port calibrated E5071C. Trigger in E5061B Start=100 MHz, Stop=500 MHz, NOP=41, IFBW=1 khz, RF OUT OFF Equation: S21/S11 Trigger : External, on-point Sweep initialized before starting MXG s sweep (by pressing Restart key ). ref. in Port-1 Port-2 Trigger out MXG Freq sweep: 100 M to 500 MHz, 41 points Output level =0 dbm, Point delay 100 ms Sweep started by pressing Single sweep key. ref. out With E5071C, measured only this part as a 3-port DUT. 11636B power divider 15 cm SMA cable 15 db pads 60 cm SMA cables (Difference of electrical lengths are compensated by setting the port extension to Port-2.) 7

Delta from normalized line(deg) Measured phase (deg) Measurement accuracy Experimental measurement (2), results The E5061B s VVM measurement exhibits ripples of 1 or 2 db even using the 15 db pads, due to significant mismatches and the divider s low isolation (=6 db) between its output ports. But overall the E5061B s measurement has a good correlation with the E5071C s S31/S21 measurement. 0-20 -40-60 -80-100 VVM measurement with E5061B S31/S21 measurement with E5071C -120 1.E+08 2.E+08 3.E+08 4.E+08 5.E+08 Frequency (Hz) Normalized to flat line 5.0 4.0 3.0 2.0 1.0 0.0-1.0-2.0-3.0-4.0-5.0 1.E+08 2.E+08 3.E+08 4.E+08 5.E+08 Frequency (Hz) VVM measurement with E5061B S31/S21 measurement with E5071C 8

Measurement accuracy Experimental measurement (3) Measured 180-degree shifted CW signals with a 180-degree power divider (30 db isolation between output ports). +7 ps port extension applied to the Port-2. Compared with the S31/S21 measurement using the full 3-port calibrated E5071C. Trigger in E5061B Start=100 MHz, Stop=500 MHz, NOP=41, IFBW=1 khz, RF OUT OFF Equation: S21/S11 Trigger : External, on-point Sweep initialized before starting MXG s sweep (by pressing Restart key ). ref. in Port-1 Port-2 Trigger out MXG Freq sweep: 100 M to 500 MHz, 41 points Output level =0 dbm, Point delay 100 ms Sweep started by pressing Single sweep key. ref. out With E5071C, measured only this part as a 3-port DUT. Minicircuits ZFSCJ-2-1 180-degree power divider 15 db pads 60 cm SMA cables (Difference of electrical lengths compensated by setting the port extension to Port-2.) 9

Measured phase (deg) Measurement accuracy Experimental measurement (3), results The E5061B s VVM measurement has a very good agreement with the E5071C s S31/S21 measurement. The ripples are small thanks to the divider s high isolation (=30 db) between its output ports. 185 184 183 182 181 180 179 178 177 176 175 1.E+08 2.E+08 3.E+08 4.E+08 5.E+08 Frequency (Hz) VVM measurement with E5061B S31/S21 measurement with E5071C 10