RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

Similar documents
RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc.

User`s Guide RIGOL. DG2000 Series Function/Arbitrary. Waveform Generator. Publication number DG March 2007

User s Guide RIGOL. DG2000 Series Function/Arbitrary Waveform Generator DG2041A/DG2021A. Publication number UGB Oct 2008

User s Guide RIGOL. DG1000 Series Function/Arbitrary. Waveform Generator. Publication number DG May 2007

User Guide RIGOL. DG3000 Series Function/Arbitrary. Waveform Generator. Publication number DG March 2007

User Guide RIGOL. DG3000 Series Function/Arbitrary Waveform Generator DG3121A/DG3101A/DG3061A. Publication number UGB May 2009

RIGOL. User s Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Dec RIGOL Technologies, Inc.

RIGOL. User s Guide. DG1022 Dual-Channel Arbitrary/Waveform Generator. Sept RIGOL Technologies, Inc.

2015 RIGOL TECHNOLOGIES, INC.

DS1000E, DS1000D Series Digital Oscilloscope

Quick Start RSDG2000X Function/Arbitrary Waveform Generator

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

SDG1000X Series Function/Arbitrary Waveform Generator. Quick Start QS0201X-E01A

User Manual SDG2000X Series Function/Arbitrary Waveform Generator UM0202X-C01A

DS1000B Series Digital Oscilloscope

RIGOL. Quick Guide. DG1000Z Series Function/Arbitrary Waveform Generator. May 2013 RIGOL Technologies, Inc.

RIGOL Service Guide. DS4000 Series Digital Oscilloscope. Mar RIGOL Technologies, Inc.

Model and

SDG6000X Series Pulse/Arbitrary Waveform Generator. Quick Start

AG Series Waveform Generator User Manual

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Single Channel. Arbitrary Waveform Generator. Quick Guide

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

User s Guide RIGOL. PA1000 Series Power Amplifier. Publication number: UGF Mar RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

RIGOL. User s Guide. DG4000 Series Function/Arbitrary Waveform Generator. Apr RIGOL Technologies, Inc.

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Rigol DG1022A Function / Arbitrary Waveform Generator

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

RIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.

Arbitrary Waveform Generator. User Manual

SSA3000X Series Spectrum Analyzer. Quick Guide

RIGOL. User s Guide. DSA1000A Series Spectrum Analyzer. July RIGOL Technologies, Inc.

RIGOL. User s Guide. DSA1000 Series Spectrum Analyzer. May RIGOL Technologies, Inc.

WaveStation Function/Arbitrary Waveform Generators

RIGOL. User s Guide. DSA1000A Series Spectrum Analyzer. Jul RIGOL Technologies, Inc.

Arbitrary/Function Waveform Generators 4075B Series

DG5000 series Waveform Generators

SFG-20X. 5 &10 MHz Arbitrary/ Function Waveform Generators. User Manual

RIGOL. Quick Guide. DS4000 Series Digital Oscilloscope. Sept RIGOL Technologies, Inc.

Arbitrary Function Generator

RIGOL. User s Guide. DSA1000 Series Spectrum Analyzer. Jan RIGOL Technologies, Inc.

User Manual. SDG5000 Series Function/Arbitrary Waveform Generator UM02050-E02A 2014 SIGLENT TECHNOLOGIES CO., LTD

WaveStation Function/Arbitrary Waveform Generators

Agilent 33250A 80 MHz Function / Arbitrary Waveform Generator. User s Guide

WaveStation Function/Arbitrary Waveform Generators

Function/Arbitrary Waveform Generator

Arbitrary Function Generator

INSTRUCTION MANUAL Arbitrary Function Generator FGX-2005 FGX-2112

Agilent 33220A. 20 MHz Waveform Generator. User's Guide. Agilent Technologies

User Manual. SDG800 Series Function/Arbitrary Waveform Generator UM02008-E02B 2014 SIGLENT TECHNOLOGIES CO., LTD

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

Specifications DG1022 & DG1022A

Data Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design

SDG6000X Series Pulse/Arbitrary Waveform Generator

DG5000 Series Specifications

RIGOL. User s Guide. DSA800 Options and Accessories. May RIGOL Technologies, Inc.

Table of Contents. 1.General Safety Requirement Safety Terms and Symbols General Inspection Quick Start...

2016 SIGLENT TECHNOLOGIES CO., LTD

Service Manual. SDG5000 Series Function/Arbitrary Waveform Generator 2017 SIGLENT TECHNOLOGIES CO., LTD

HP 33120A Function Generator / Arbitrary Waveform Generator

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

Agilent 33210A 10 MHz Function / Arbitrary Waveform Generator. User s Guide

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

RIGOL. User s Guide. DM3068 Digital Multimeter. Feb RIGOL Technologies, Inc.

User Manual. TDS 420A, TDS 430A, TDS 460A & TDS 510A Digitizing Oscilloscopes

AWG-4105/AWG-4110/AWG-4150

Chapter 13 Specifications

User Manual. TDS 420A, TDS 430A, TDS 460A & TDS 510A Digitizing Oscilloscopes

RIGOL. User s Guide. DSA800 Options and Accessories. Dec RIGOL TECHNOLOGIES, INC.

Agilent Pulse Function Arbitrary Noise Generator

Dual-Channel Arbitrary Waveform Generator. User Manual

RIGOL Data Sheet. DG1022 Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

SIGLENT User Manual. SDG1000 Series Function/Arbitrary Waveform Generator SDG1005/SDG1010/SDG1020/SDG1025/SDG SIGLENT Technologies Co.

Arbitrary/Function Generator AFG1000 Series Datasheet

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR

8120 FUNCTION GENERATOR Operation Manual

Model MHz Arbitrary Waveform Generator Specifications

Function/Arbitrary Waveform Generator

RIGOL 快速指南 MSO4000/DS4000 系列数字示波器 2014 年 2 月. RIGOL Technologies, Inc.

Function/Arbitrary Waveform Generator

Function Generator Guide Tektronix AFG3102

RIGOL. Quick Guide. DS4000 Series Digital Oscilloscope. Aug RIGOL Technologies, Inc.

Maximum output frequency:160 MHz, 100 MHz, 60 MHz 500MSa/s sample rate, 14 bits vertical resolution Dual Channel Outputs With Identical Performance

RIGOL User s Guide. MSO7000/DS7000 Series Digital Oscilloscope. Apr RIGOL TECHNOLOGIES, INC.

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Model 4007DDS. 7 MHz Sweep Function Generator

RIGOL. User s Guide. DS4000 Series Digital Oscilloscope. Feb RIGOL Technologies, Inc.

DG4000 Series Waveform Generators

Economical Type 1 channel. Arbitrary Waveform Generator. User Manual GV 20

DG900. Series. Function/Arbitrary Waveform Generator RIGOL 1

Function/Arbitrary Waveform Generator

G5100A: 50 MHz Arbitrary Function Generator

AFG2021 Arbitrary Function Generator Specifications and Performance Verification Technical Reference

Table of Contents. 1. General Safety Requirements Safety Terms and Symbols Quick Start... 4

SPM-50 RF Spectrum Power Meter PC Software User Manual

DG800. Series. Function/Arbitrary Waveform Generator RIGOL 1

Transcription:

Quick Guide DG2000 Series Function/Arbitrary Waveform Generator Sept. 2010 RIGOL Technologies, Inc.

Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL Technologies, Inc. Notices RIGOL products are protected by patent law in and outside of P.R.C. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision. Information in this publication replaces all previously corresponding material. RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing, use or performance of this manual as well as any information contained. Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of RIGOL. Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China. International standard conformance certification is in progress, e.g. ISO. Contact Us If you have any problem or requirement when using our products, please contact RIGOL Technologies, Inc. or your local distributors, or visit: www.rigol.com I

Safety Notice Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injuries or damages to the instrument and any product connected to it. To prevent potential hazards, please use the instrument only specified by this manual. Use Proper Power Cord. Only the power cord designed for the instrument and authorized by local country could be used. Ground The Instrument. The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric shock, it is essential to connect the earth terminal of power cord to the Protective Earth terminal before any inputs or outputs. Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting. Do Not Operate Without Covers. Do not operate the instrument with covers or panels removed. Avoid Circuit or Wire Exposure. Do not touch exposed junctions and components when the unit is powered. II

Do Not Operate With Suspected Failures. If you suspect damage occurs to the instrument, have it inspected by qualified service personnel of RIGOL before further operations. Keep Well Ventilation. Inadequate ventilation may cause increasing of temperature or damages to the device. So please keep well ventilated and inspect the intake and fan regularly. Do Not Operate in Wet Conditions. In order to avoid short circuiting to the interior of the device or electric shock, please do not operate in a humid environment. Do Not Operate in an Explosive Atmosphere. In order to avoid damages to the device or personal injuries, it is important to operate the device away from an explosive atmosphere. Keep Product Surfaces Clean and Dry. To avoid the influence of dust and/or moisture in air, please keep the surface of device clean and dry. III

Safety Terms and Symbols Terms in this Manual. These terms may appear in this manual: WARNING Warning statements indicate the conditions or practices that could result in injury or loss of life. CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury or hazard may immediately happen. WARNING indicates an injury or hazard may be accessible potentially. CAUTION indicates a potential damage to the instrument or other property might occur. Symbols on the Product. These symbols may appear on the product: Hazardous Voltage Refer to Instructions Protective Earth Terminal Chassis Ground Test Ground IV

Content Guaranty and Declaration... I Safety Notice... II Safety Terms and Symbols... IV Quick Start... 1 General Inspection... 1 Handle Adjustment... 2 The Front/Rear Panel... 3 Device Connection... 5 Power Connection... 5 USB Connection... 5 BNC Connection... 5 User Interface... 6 To Set a Waveform... 7 To Use the Mod/ Sweep/Burst Function... 11 To Trigger/Output... 13 To Use the Digital Input... 14 To Use the Store/Utility/Help Function... 15 Troubleshooting... 16 V

Quick Start General Inspection 1. Inspect the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the unit. 2. Inspect the instrument In case of any damage, or defect, or failure, notify your RIGOL sales representative. 3. Check the accessories Please check the accessories according to the packing lists. If the accessories are incomplete or damaged, please contact your RIGOL sales representative. 1

Handle Adjustment To adjust the handle position of DG2000 Function/ Arbitrary Waveform Generator, please grip the handle by the sides and pull it outward. Then, make the handle rotate to the desired position. The operating methods are shown below. Adjusting the Handle Viewing Positions Carrying Position 2

The Front/Rear Panel This section will make a brief introduction and description for the operation and functions of the Front/ Rear Panel of DG2000 Series Function/ Arbitrary Waveform Generator. Front Panel at a Glance DG2000 has clear and simple front panel. The Front Panel has a knob, functional keys and menu softkeys. The 6 grey keys below the screen are menu softkeys, with the help of which, you can choose different options on the current menu. The rests are the functional keys, with which you can enter different function menus or obtain specific functional applications directly. LCD Screen Mode/ Functions Direction Keys Knob USB Host Power Key Graph/ Text Mode Key Menu Operation Softkeys Waveform Selection Keys Number Keys Output Control Trigger Control Output Connector Sync Output! CAUTION: The [Output] and [Sync] connectors on the front panel can be only used for the signal output. If they are used for input, it may make the circuit burned and the instrument in trouble. 3

Rear Panel at a Glance 10MHz Reference Input 10MHz Reference Terminal Output Terminal 10/100 Ethernet GPIB ( IEEE 488 ) Power Socket Modulation Input Terminal Digital External Output Trig/FSK/Burst USB Device RS232 Main Power Switch Signs for the panel keys in this manual: The signs for the panel keys in this manual are the same as the panel keys. Please note that the signs for the functional keys on the operation panel are represented by squared words, such as Sine, which represents the transparent functional key with Sine on it on the front panel, while the menu softkeys are represented by shadow words such as Frequency, which means the Frequency option in the Sine menu. 4

Device Connection Power Connection Connect the power socket and AC supply with power cord attached to the instrument. Turn on the power switch at the rear panel to power on the generator, then press the power key on the front panel to start the instrument immediately. If start abnormally, please check according to the following steps: 1. Check if the power cord is normally connected and the power switch on the rear panel has been turned on. 2. Check if the fuse is intact, or esle please replace it. 3. If the instrument still cannot be started, contact RIGOL for help. USB Connection USB Host: This port is used to transfer data when external USB device connects to the generator regarded as a Host device. For example, connect a USB flash device for data storage. USB Device: This port is used to transfer data when external USB device connects to the generator regarded as a Slave device. For example, connect with PC for remote control. BNC Connection Interfaces need to be connected by BNC Cable include: [Sync], [Output] on the front panel and [10MHz In], [10MHz Out], [Modulation In], [Ext Trig/FSK/Burst] on the rear panel. Insert BNC cable to the connector vertically, and rotate clockwise to lock it. 5

User Interface DG2000 Series Function/ Arbitrary Waveform Generator provide two display modes: Menu and Graph. These two display modes can be switched to each other by pressing the Menu Display Mode /A key. Under the Menu display mode, the display interface is divided into these parts: state, waveform icon, operation menu, and parameter display. See the figure below. State Waveform Icon Operation Menu Parameter Display Graph Display Mode Under the Graph display mode, you can check the current waveform parameters in the graphics. The display interface is also divided into these parts: state, parameter display, display menu softkey and waveform display. See the figure below. The operation menu will appear at the bottom of the screen when you press any menu softkey. Parameter Display State Parameters Display Menu button Waveform Display 6

To Set a Waveform At the left of the operation panel, there is a set of keys with waveform icon. The exercise below will help you familiarized with the waveform selection settings. The instructions of the waveform setting are all carried out in the Menu Display Mode. 1. Press Sine, the waveform icon turns into Sine with a Sine typeface in the state area. DG2000 Series Generator can generate Sine signal with frequency from 1μHz to 40MHz. By setting Frequency/Period, Amplitude/ High Level, Offset/ Low level, the Sine signal with different parameters can be generated. As shown in the figure above, the default signal parameters are: 1kHz Frequency, 5.0 Vpp Amplitude and 0Vdc Offset. 2. Press Square, the waveform icon turns into Square with a Square typeface in the state area. DG2000 Series Generator can generate Square signal with frequency from 1μHz to 40MHz and variable duty cycle. By setting Frequency/Period, Amplitude/ High Level, Offset/ Low level, and Duty Cycle, the Square signal with different parameters can be generated. 7

As shown in the figure above, the default signal parameters are: 1kHz Frequency, 5.0 Vpp Amplitude, 0 Vdc Offset and 50% Duty Cycle. 3. Press Ramp, the waveform icon turns into Ramp with a Ramp typeface in the state area. DG2000 Series Generator can generate Ramp signal with frequency from 1μHz to 400 khz and variable Symmetry. By setting Frequency/Period, Amplitude/ High Level, Offset/ Low level, and Symmetry, the Ramp signal with different parameters can be generated. As shown in the figure above, the default signal parameters are: 1kHz Frequency, 5.0 Vpp Amplitude, 0 Vdc Offset and 50% Symmetry. 4. Press Pulse, the waveform icon turns into Pulse with a Pulse typeface in the state area. DG2000 Series Generator can generate Pulse signal with frequency from 500μHz to 16MHz and variable Pulse Width and Edge Time. By setting Frequency/Period, Amplitude/ High Level, Offset/ Low level, Pulse Width and Edge Time, the Pulse signal with different parameters can be generated. 8

As shown in the figure above, the default signal parameters are: 1kHz Frequency, 5.0 Vpp Amplitude, 0 Vdc Offset, 20% Duty Cycle and 50ns Edge Time. 5. Press Noise, the waveform icon turns into Noise with a Noise typeface in the state area. DG2000 Series Generator can generate Noise signal with Band Width up to 20MHz. By setting Amplitude/ High Level, Offset/ Low level, the Noise signal with different parameters can be generated. As shown in the figure above, the default signal parameters are: 5.0 Vpp Amplitude and 0 Vdc Offset. 6. Press Arb, the waveform icon turns into Arb with an Arb typeface in the state area. DG2000 Series Generator can generate repeatable arbitrary waveform signals with at most 512K points and 12MHz frequency. By setting Frequency/Period, Amplitude/ High Level, Offset/ Low level, arbitrary waveform signals with different parameters can be generated. 9

As shown in the figure above, the default Exponential Rise Signal parameters are: 1kHz Frequency, 5.0 Vpp Amplitude and 0 Vdc Offset. 7. Digital is a reserved function key for the Logic Signal Output Module. Note: Description of the parameter range based on the DG2041A model in this section. 10

To Use the Mod/ Sweep/Burst Function As shown in the figure below, there are three keys on the front panel, which are used for Mod, Sweep and Burst settings. The instructions below will help you familiarize with the setting of these functions. 1. Press Mod, a modulated waveforms will be generated. DG2000 Series can generate AM, FM, PM, PWM and FSK modulate waveforms. Parameters are set by using the menu softkeys. The modulated waveform can be changed by changing the parameters such as Type, Internal/External Modulation, Depth, Frequency, Waveform, etc. 2. Press Sweep, Sine, Square, Ramp or Arbitrary waveform can be swept (Pulse, Noise and DC cannot be swept). In the Sweep Mode, DG2000 Series generate signal with variable frequencies. 11

3. Press Burst, Burst for Sine, Square, Ramp, Pulse or Arbitrary waveform can be generated (Noise can only be used in the gated Burst). Term Explanation Burst: Output Waveforms with set cycle times Burst can last for certain times of waveform cycle (N-Cycle Burst) or be controlled by external gated signals (Gated Burst). Burst applies to all kinds of waveforms, but noise can only be used in gated burst. Generally it is called BURST function within every Signal Generator. 12

To Trigger/Output As shown in the figure below, there are two keys on the right side of the operation panel, which are used to set Trigger and Output Control. The instruction below will help you familiarize with these functions. 1. Press Trigger, choose internal/external or manual Trigger (Manual Trigger can only be used in Sweep and N-Cycle Burst) The default setting for Trigger is Internal. In this mode, when the Sweep or Burst Mode is also selected, the Generator will continuously generate sweep or burst waveform. At this time, press Trigger, the instrument will shift from the Automatic Trigger mode into Manual Trigger mode. When the generator uses the External Trigger Mode, if the Sweep or the Burst Mode is selected, the signal will be continuously generated. At this time, press Trigger, the instrument state will not change, and it will show the information The instrument has already been triggered. Every time you press the Trigger, Manual Trigger will start a sweep or generate a burst. Press the key again, and the generator will be triggered again. 2. Press Output, activate or deactivate the output signal. If an overload message is shown, disconnect the external equipment from the [Output] terminal and press Output, reactivate the output terminal. 13

To Use the Digital Input As shown in the figure below, there are two groups of keys on the operation panel, which are the direction keys, the knob and the keyboard. The instruction below will help you familiarize with the Digital Input Function. Direction Keys and the Knob Keyboard 1. Use the Direction keys to move the cursor left or right. Rotate the knob to change a digit (clockwise to increase 1), and the range of digit is 0~9. 2. Use the Keypad to set the parameters values of the waveforms, which can change its value directly. 14

To Use the Store/Utility/Help Function As shown in the figure below, there are three keys on the operation panel, which are used to call the store/recall, utility and help function. The instruction below will help you familiarize with these Functions. 1. The Store/Recall key is used to store waveform data and configure information. 2. The Utility key is used to set the auxiliary system function, change the output configure parameters, interface setting, system setting information or perform the instrument self-test and read the calibration information, etc. 3. The Help key is used to see the help information. Get help on any key: To get help on any key of the front panel, press the key and last for about 1 second, then the help message will appear. 15

Troubleshooting 1. If the screen does not turn on even if the generator is on, please follow the steps below: (1) Check if the power is correctly connected. (2) Check if the power switch is really on. (3) Restart the instrument after taking the above steps. (4) If it does not work correctly, contact RIGOL for our service. 2. If the settings are correct but no waveform is generated, please follow the steps below: (1) Check if the Signal Line is correctly connected to the [Output] terminal. (2) Check the BNC if it works correctly. (3) Check the Output key, if it is turned on. (4) Press Utility System Setting PowOn Latest when all the above steps have been finished. Restart the computer. 3. The U-disk cannot be recognized: (1) Check if the U-disk can work normally. (2) Make sure the U-disk is USB flash disk. The generator doesn t support hard drive-based U-disk. (3) Restart the instrument, reinsert the USB device and check it. (4) If the U-disk still does not work normally, please contact RIGOL. 16