Power supply CP-D 12/2.1

Similar documents
Power supply CP-D 24/1.3

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/20.0

Power supply CP-E 24/2.5

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

CP-E range Benefits and advantages

Primary switch mode power supplies Product group picture

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

CP-T range Product group picture

CP-T range Benefits and advantages

Electronic timer CT-SDS.22

Electronic timer CT-TGD.22

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDD.22

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFS

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Liquid level monitoring relay CM-ENS.2x

Three-phase monitoring relay CM-PVE

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PBE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relay

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-MFS.21

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Control module CP-A CM

QUINT-PS-24DC/24DC/10

MINI-PS AC/24DC/1.3

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Three-phase monitoring relay

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

MINI-PS AC/2X15DC/1

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

QUINT-PS AC/24DC/40

Analog signal converters CC-E I/I

QUINT-PS/ 3AC/24DC/10

Control module CP-A CM

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Pluggable interface relays CR-U Universal relays

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Analog signal converters CC range

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

QUINT-PS/ 3AC/24DC/40

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS/ 1AC/24DC/20

Thermistor motor protection relays

Transcription:

2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power 30 W Wide range input 100 240 V AC (90 264 V AC, 120 375 V DC) Efficiency of typ. 80 % Low power dissipation and low heating Free convection cooling (no forced cooling with ventilators) Ambient temperature range during operation 40...+70 C Open circuit, overload and short circuit stable Integrated input fuse U/I characteristic (fold forward behaviour at overload no switch off) LEDs for status indication Structural form ideal for installation in distribution panels Light grey enclosure in RAL 7035 b INPUT L, N: terminals input c DC ON: green LED output voltage applied d DC LOW: red LED output voltage too low e OUTPUT Adjust: potentiometer adjustment of output voltage f Circuit diagram Approvals A UL 508, CAN/CSA C22.2 No.14 *) H UL 1310, CAN/CSA C22.2 No.223 *) (Class 2 Power Supply) H UL 60950, CAN/CSA C22.2 No.60950 *) D GOST E CCC *) ~ *) Approval refers to rated input voltage U in Marks a CE b C Tick pending Order data Type Input voltage range Rated output voltage / current Order code CP-D 12/2.1 90 264 V AC / 120-375 V DC 12 V DC / 2.1 A Application The primary switch mode power supply has two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped with two generous capacitors, which ensure mains buffering of at least 30 ms. That is why the device can be used worldwide also in high fluctuating networks and battery powered plants. Operating mode Adjustable output voltage This device features an continuously adjustable output voltage from 12 14 V DC. Thus they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. 1

Installation Mounting The switch mode power supply can be snapped on a DIN rail according to IEC/EN 60715 as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC 272 040 F0b07 Demounting Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Alternatively you can press the unlock button to release the device. Then in both cases the device can be unhinged from the mounting rail edge and removed. Mounting position The devices have to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to other modules should not be less than 25 mm in vertical direction and horizontal direction. 2CDC 272 043 F0b07 2CDC 272 041 F0b07 Electrical connection Connect the input terminals L and N. The installation must be executed acc. to EN 60950, provide a suitable disconnecting device (e. g. line protection switch) in the supply line. The input side is protected by an internal input fuse. Rate the lines for the maximum output current or provide a separate fuse protection. We recommend to choose the cable section as large as possible in order to minimize voltage drops. Observe the polarity. Actuate plug connector only when power is off. The device is overload, short circuit and open circuit proof. The secondary side of the power supply is electrically isolated from the input and internally not earthed (SELV) and can therefore be earthed by the user according to the needs with + or (PELV). 2

Connection diagram(s) + + - - L PWM N L N + - 2CDC 272 039 F0b07 + +, Output voltage L, N Input voltage Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national regulations (e. g. VDE, etc.). CP D power supplies are chassis mounted units. They are maintenance free and do not contain any integral setting elements and should therefore not be opend. Before any installation, maintenance or modification work: Disconnect the system from the supply network and protect against switching on! Before start of operation the following must be ensured: Connect to main according to the specific national regulations. Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the end product to disengage unit and supply cables from supply mains if required. Rate the output lines for the output current of the power supply and connect them with the correct polarity. In order to ensure sufficient air cooling the distance to the other devices has to be considered. Attention! Improper installation/operation may impair safety and cause operational difficulties or destruction of the unit. In operation pay attention to: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)! Risk of burns: Depending on the operation conditions the enclosure can become very hot. If the internal fuse blows, most probably the device is defect. In this case, an examination of the switch mode power supply by the manufacturer is necessary. Attention! Danger to life! Disconnect the system from the supply network before executing any works at the device and protect against switching on! The power supply contains components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. 3

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, unless otherwise indicated Input circuits - Supply circuits Rated input voltage U in L, N 100 240 V AC Typical input current / power consumption 110 V AC 230 V AC 100 240 V AC 502 ma / 31.14 W 277 ma / 31.2 W Input voltage range AC 90 264 V AC DC 120 375 V DC Frequency range AC 47 63 Hz Inrush current limiting 50 A max. 3 ms Power failure buffering time min. 30 ms Internal input fuse (apparatus protection, not accessible) 2 A slow acting / 250 V AC Power factor correction (PFC) no Indication of operational states Output voltage DC ON: green LED V: output voltage applied DC LOW: red LED V: output voltage too low Operating controls Potentiometer OUTPUT Adjust: Potentiometer OUTPUT Adjust Output adjustment Output circuits Rated output voltage ++, 12 V DC Tolerance of the output voltage ± 1 % Adjustment range of the output voltage Rated output power 12 14 V DC Rated output current I r T a 60 C 2.1 A Derating of the output current 60 C < T a 70 C 2.5 %/ C Deviation load change statical max. 1 % Control time change of output voltage within the input voltage range 30 W max. 1 % < 1 ms Starting time after applying supply voltage at I r 1000 ms Rise time at rated load typ. 1 ms Residual ripple and switching peaks BW = 20 MHz 50 mv Parallel connection Series connection Resistance to reverse feed Characteristic curve of output Short circuit protection Short circuit behaviour Current limiting at short circuit Overload protection Overvoltage protection No load protection Starting of capacitive loads yes, use of CP-D RU required yes, to increase voltage 18 V / 1 s U/I characteristic curve continuous short circuit stability continuation with output power limiting typ. 5.9 A output power limiting 15-16.5 V DC continuous no load stability unlimited 4

General data Duty time 100 % Dimensions (W x H x D) 53 x 91 x 57.5 mm (2.09 x 3.58 x 2.26 inches) Material of housing housing Plastic Efficiency typ. 82 % Weight Mounting position Minimum distance to other units 0.196 kg (0.42 lb) horizontal normal operation mode horizontal 25 mm (0.98 inch) vertical 25 mm (0.98 inch) Mounting DIN rail (IEC/EN 60715), snap on mounting without any tool Degree of protection housing / terminals IP20 / IP20 Class of protection II Electrical connection Input circuit / Output circuit Wire size Stripping length Tightening torque fine strand with wire end ferrule Screw connection 0.2 2.5 mm 2 (24 14 AWG) rigid 0.2 2.5 mm 2 (24 12 AWG) 7 mm (0.28 in) 0.7 Nm (6 lb.in) Environmental data Ambient temperature range operation 40...+70 C full load 40...+60 C storage 40...+85 C Damp heat, cyclic (IEC/EN 60068 2 30) Vibration, half sine (IEC/EN 60068 2 6) Shock, half sine (IEC/EN 60068 2 27) 4 x 24 h cycles, 40 C, 95 % RH 50 m/s 2, 10 Hz 2 khz 40 m/s 2, 22 ms Isolation data Rated isolation voltage U i input circuit / output circuit 3 kv AC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) II Standards / Directives Product standard EN 61204 EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC Electrical safety UL 508, UL 60950 1, EN 60950 1 Protective low voltage SELV (EN 60950 1) 5

Electromagnetic compatibility Interference immunity to IEC/EN 61000 6 2 electrostatic discharge IEC/EN 61000 4 2 Level 4 (4 kv / 15 kv) radiated, radio-frequency, electromagnetic field IEC/EN 61000 4 3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000 4 4 Level 4 (4 kv) surge IEC/EN 61000 4 5 Level 3 (2 kv L L) conducted disturbances, induced by radiofrequency fields IEC/EN 61000 4 6 Level 3 (10 V) Interference emission IEC/EN 61000 6 3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B 6

Technical diagrams 12 11 10 9 8 7 6 5 4 3 2 1 0 0 Output behaviour Uout [V] 0.5 1 1.5 2 2.5 3 3.5 4 Iout [A] Characteristic curve of output at T a = 25 C 2CDC 272 020 F0207 The switch mode power supply CP D 12/2.1 is able to supply at 12 V DC output voltage and at an ambient temperature of: 60 C a continuous output current of approx. 2.1 A at ambient temperatures of: 60 C < T a 70 C the output power has to be reduced by 2,5 % per C temperature increase. If the switch mode power supply is loaded with an output current > 2.1 A, the operating point is passing through the U/I characteristic curve shown. Temperature behaviour Pout [%] 100 90 80 70 60 50 40 30 20 10-10 0 10 20 30 40 50 60 70 Ta [ C] 2CDC 272 018 F0207 Characteristic curve of temperature at U out Dimensions in mm 53,0 [2.09 ] 67,0 [2.64 ] 44,5 [1.75 ] 91,0 [3.58 ] 32,1 [1.26 ] 49,0 [1.93 ] 57,5 [2.26 ] 2CDC 272 012 F0b07 CP-D 12/2.1 7

Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C02xx Power Supply Units Application manual 2CDC 114 048 M020x You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Power Supplies. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Power Supplies -> CP-D - Power Supplies. 8

Contact us STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 053 D0201 (08/12) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright 2012 All rights reserved