INTERIOR FINISHES CHAPTER 8

Similar documents
SPECIAL CONSTRUCTION

CHAPTER 10 MEANS OF EGRESS. User Note: See Pref ace page iv ( mar ginal mark ings ) for Chap ter 10 reor ga ni za tion in for ma tion.

Jun ior Cer tifi cate Ex ami na tion, 2003 Ma te ri als Tech nol ogy (Wood) Mon day 16 June - Morning Sec tion A- Higher Level 40 marks

The Dramatic Publishing Company

SM 15K - Series 15kW DC POWER SUP PLIES

SM 15K - Series 15kW DC POWER SUP PLIES

SM 15K - Series 15kW DC POWER SUP PLIES

SM se ries watts DC POWER SUP PLIES

KDH-1B Weigh Module Installation Instructions

SM Series 3300 W DC POWER SUP PLIES

SAVING ENERGY THROUGH IMPROVING CONVECTION IN A MUFFLE FURNACE. Alina Adriana MINEA and Adrian DIMA

SX - se ries 75 SX 5

SM Series 3300 W DC POWER SUP PLIES

SM Series 3300 W DC POWER SUP PLIES

SM series watts DC POWER SUP PLIES

SX - se ries 150 SX 15-15

INFLUENCE OF RUNNING CONDITIONS ON RESONANT OSCILLATIONS IN FRESH-AIR VENTILATOR BLADES USED IN THERMAL POWER PLANTS

Exsultet [AT THE EASTER VIGIL]

En vi ron men tal Planning, Prevention And Di sas ter Re sponse In The Ara bian Gulf

SM Se ries 800 W DC POWER SUP PLY

SM Se ries 6000 W DC POWER SUP PLIES DELTA ELEKTRONIKA B.V. Mod els Volt age range Cur rent range. Three phase input

Filter-Based Synthetic Transmit and Receive Focusing

1073 & 1084 Channel Amplifier

Ra ti omet ric Lin ear Hall Ef fect Sen sor

En ter prise Re source Plan ning (ERP) Sys tem: An Ef fec tive Tool for Pro duc tion Man age ment

Guide line for thin layer hot mix as phalt wearing courses on residential streets

Capacitor, De-tuned Capacitor & Filter Bank Products. The ABB Solution to Harmonics

Trans par ency, Ac cess to In for ma tion, and Well-Be ing

Charles Hertan. Power Chess for Kids. Learn How to Think Ahead and Be come One of the Best Play ers in Your School

SAMPLE KYRIE. Dm (Em) Dm (Bm) (Bm) (G) (Em) (Bm) (D) Chri ste. ri e e. son. ri e e lé. Gm7 F (G) Gm7. (Bm) (Em7) (D) (Em7) (D) son. Chri ste.

Proportional Reasoning

African trade ministers to meet on WTO challenges

EXPERIMENTAL RESEARCH OF LIMITS FOR THERMAL MODULATION TRANSFER FUNCTION. Ljubiša D. TOMI] and Mom~ilo P. MILINOVI]

ASTER Imagery for British Columbia An Online Exploration Resource 1

Im por tant Note 1. Mains Sup ply (rack units) 4 DC Power Sup ply In di ca tors (rack units) Mod ule Mod ule 7

FT Frequency divider. Instruction Manual

Check mate for Chil dren

APC-30T. Omni-Purpose 30 Watt Wide Angle Horn Loudspeaker. General Description. Features. Specifications. Applications APC-30T

Telex. Op er at ing In struc tions ST300. Transmitter SR Channel Receiver SR-50. Single Channel Receiver

Picosecond Vi bra tional Spec tro scopy of Intermolecular Energy Transfer and Overtone Re lax ation in Liquid Bromoform

FT 9003 Frequency divider. Instruction Manual

All improvements of David(R)zehn!

Organized Small-scale Self-help Housing

JCR-VIS Credit Rat ing Com pany Lim ited June, 2002

The Paschal Proclamation

General Council approves work programme on implementation problems of developing countries

MASS OF SAINT ISAAC JOGUES

Low Cost, Single-Supply Differential Amplifi er AD626

THAT Corporation APPLICATION NOTE 103

Ta ble of Con tents. Table of Contents

THERE ARE A lim ited num ber of bids

AC CES SORY DE CODER MX82E, MX82D, MX82V

JB1010 Ten-Channel Junction Box

Stitch ing Sto ries from Bihar to Beeston

Pu shing and bra king aid. Trans la ti on of the ori gi nal user's manual. movilino

Moore spells out priorities for Seattle Ministerial Conference

In te grated En do scope for Real-Time 3D Ul tra sound Im ag ing and Hyperthermia: Fea si bil ity Study

AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay

Padmount Style SF6 Insulated Switching Solutions

Les s on Objectives. Student Files Us ed. Student Files Crea ted

American Physical Society March Meeting 2016 Sing-along / Listen-along! Sheet music

Seattle preparations enter new phase. EC, US accept compromise on banana dispute. Inside. Jan u ary-february 1999 No. 37

Air craft Noise versus Re spect for Home and Pri vate Life. Chapter XVI Air craft Noise ver sus Re spect for Home and Pri vate Life.

Agriculture, services negotiations move on to next phase

Przesłuchania do chóru "Muzyka zespołu Queen symfonicznie" TENOR

New Zealand s Moore heads WTO

A Bit Serial Input, Constant-Current Latched LED Driver

SM se ries watts DC POWER SUP PLIES

The Easter Proclamation: the Exsultet

Man ual on col lec tive bar gain ing and dispute resolution in the Pub lic Ser vice

SI-3010LLSL. Linear. Regulators. 1.5 A, Ultra-Low-Dropout, 1~3.3 V Regulator

De voted to Prof. Pavel Povinec 65-th an ni ver sary

(12) Patent Application Publication (10) Pub. No.: US 2012/ A1

Sin gle-el e ment Fo cused Ul tra sound Trans ducer Method for Har monic Mo tion Im ag ing

Chinese Empire. Chinese Empire

WTO members urge open markets as preparations start for 3rd Ministerial

ES TI MA TION OF DOSES RE CEIVED BY OP ER A TORS IN THE 1958 RB RE AC TOR AC CI DENT US ING THE MCNP5 COM PUTER CODE SIMULATION

Living in Unauthorized Settlements. Hous ing Im prove ment and Social Participation in Bolivia

DE COM MIS SION ING OF NU CLEAR FA CIL I TIES AT THE NU CLEAR RE SEARCH IN STI TUTE REZ PLC

Promoting water-related innovation through networked acceleration

SERIAL # OWNERS MANUAL PARACHUTE LABORATORIES INC LEXINGTON AVE. SUITE 106 DELAND, FL. USA

(12) Patent Application Publication (10) Pub. No.: US 2016/ A1

Cases Deal ing with Communication. Cases with Strong Rep re sen ta tion of Topic. Alice s Expense Account. Chemplus Inc. (B) The Auto Fi nance Cen tre

Power Chess for Kids Volume 2

METASEMANTICS AND OBJECTIVITY

Cosmic Fruit Bowl. Comedy by Rosemary Frisino Toohey. The Dramatic Publishing Company

351 En gi neer ing Ter race, mail code Amsterdam Avenue New York, NY

CRITICAL REVIEW OF THERMOELECTRICS IN MODERN POWER GENERATION APPLICATIONS. Khalid M. SAQR and Mohd N. MUSA

MASS OF SAINT ISAAC JOGUES

Wis con sin MAPPING BUL LE TIN Vol. 28, num ber 1 Winter 2002

ORTEC R.F.C. GmbH PF 1103, D Landshut, Ger many Tel.: Fax:

4,695,748 Sep. 22, 1987

AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions

Nov. 18, S. P. Rockwell HARDNESS TESTING MACHINE 1, Filed Sept. 2 Sheets-Sheet II. lill, INVENTOR.

Wis con sin MAPPING BUL LE TIN Vol. 29, num ber 1 Winter 2003

EN VI RON MEN TAL DEG RA DA TION OF CAR BON NANOTUBE-MOD I FIED COM POS ITE LAM I NATES: A STUDY OF ELECTRICAL RESISTIVITY

COURSE DESCRIPTIONS Accounting (ACCT) Agricultural Economics (AGEC) Anthropology (ANTH) Biology (BIOL)

ABSTRACTS. 1. Quantatative Ultrasound 1

PARALLEL SIMPLEX FOR LARGE PURE NETWORK PROBLEMS: COMPUTATIONAL TESTING AND SOURCES OF SPEEDUP. Richard S. Barr 1 Betty L.

Crawling Waves from Radiation Force Excitation

Transcription:

CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Pro vi sions of this chap ter shall gov ern the use of materials used as interior finishes, trim and decorative materi - als. 801.1.1 In te rior fin ishes. These pro vi sions shall limit the al low able flame spread and smoke de vel op ment based on lo ca tion and oc cu pancy clas si fi ca tion. Exceptions: 1. Ma te rials hav ing a thick ness less than 0.036 inch (0.9 mm) ap plied di rectly to the sur face of walls or ceilings. 2. Ex posed por tions of struc tural mem bers com ply - ing with the re quire ments for build ings of Type IV con struc tion in Sec tion 602.4 shall not be sub ject to in te rior fin ish re quire ments. [F] 801.1.2 Dec o ra tive ma te ri als and trim. Decorative materials and trim shall be restricted by combustibility and flame re sis tance in ac cor dance with Sec tion 805. 801.1.3 Ap pli ca bil ity. For build ings in flood haz ard ar eas as es tab lished in Sec tion 1612.3, in te rior fin ishes, trim and dec o ra tive ma te ri als be low the de sign flood el e va tion shall be flood-damage-resistant materials. 801.2 Ap pli ca tion. Combustible materials shall be permitted to be used as fin ish for walls, ceil ings, floors and other in te rior sur faces of build ings. 801.2.1 Win dows. Show win dows in the first story of build - ings shall be per mit ted to be of wood or of un pro tected metal fram ing. 801.2.2 Foam plas tics. Foam plas tics shall not be used as in te rior fin ish or trim ex cept as pro vided in Sec tion 2603.8 or 2604. SECTION 802 DEFINITIONS 802.1 Gen eral. The fol low ing words and terms shall, for the pur poses of this chap ter and as used else where in this code, have the mean ings shown herein. EX PANDED VI NYL WALL COVERING. Wall cov er ing con sist ing of a wo ven tex tile back ing, an ex panded vi nyl base coat layer and a nonexpanded vi nyl skin coat. The ex panded base coat layer is a ho mo ge neous vi nyl layer that con tains a blow ing agent. Dur ing pro cess ing, the blow ing agent de com - poses, caus ing this layer to ex pand by form ing closed cells. The to tal thick ness of the wall cov er ing is ap prox i mately 0.055 inch to 0.070 inch (1.4 mm to 1.78 mm). FLAME RE SIS TANCE. That prop erty of ma te ri als or com - bi na tions of com po nent ma te ri als that re stricts the spread of flame in ac cor dance with NFPA 701. FLAME SPREAD. The prop a ga tion of flame over a sur face. FLAME SPREAD IN DEX. The nu mer i cal value as signed to a ma te rial tested in ac cor dance with ASTM E 84. IN TE RIOR FIN ISH. Interior finish includes interior wall and ceil ing fin ish and in te rior floor fin ish. IN TE RIOR FLOOR FIN ISH. The ex posed floor sur faces of build ings in clud ing cov er ings ap plied over a fin ished floor or stair, including risers. IN TE RIOR WALL AND CEIL ING FIN ISH. The ex posed in te rior sur faces of build ings in clud ing, but not lim ited to: fixed or mov able walls and par ti tions; col umns; ceil ings; and interior wainscotting, pan el ing or other fin ish ap plied struc tur - ally or for dec o ra tion, acous ti cal cor rec tion, sur face in su la tion, struc tural fire re sis tance or sim i lar pur poses, but not in clud ing trim. SMOKE-DEVELOPED INDEX. The nu mer i cal value as - signed to a ma te rial tested in ac cor dance with ASTM E 84. TRIM. Pic ture molds, chair rails, base boards, hand rails, door and window frames and similar decorative or protective materi als used in fixed ap pli ca tions. SECTION 803 WALL AND CEILING FINISHES 803.1 Gen eral. In te rior wall and ceil ing fin ishes shall be clas - si fied in ac cor dance with ASTM E 84. Such in te rior fin ish ma - te ri als shall be grouped in the fol low ing classes in ac cor dance with their flame spread and smoke-de vel oped in dexes. Class A: Flame spread 0-25; smoke-de vel oped 0-450. Class B: Flame spread 26-75; smoke-de vel oped 0-450. Class C: Flame spread 76-200; smoke-de vel oped 0-450. Exception: Ma te rials, other than tex tiles, tested in ac cor - dance with Sec tion 803.2. 803.2. In te rior wall or ceil ing fin ishes other than tex tiles. In te rior wall or ceil ing fin ishes, other than tex tiles, shall be per - mit ted to be tested in ac cor dance with NFPA 286. Fin ishes tested in ac cor dance with NFPA 286 shall com ply with Sec tion 803.2.1. 803.2.1 Ac ceptance criteria. Dur ing the 40 kw ex po sure, the in te rior fin ish shall com ply with Item 1. Dur ing the 160 kw ex po sure, the in te rior fin ish shall com ply with Item 2. Dur ing the en tire test, the in te rior fin ish shall com ply with Item 3. 1. Dur ing the 40kW ex po sure, flames shall not spread to the ceil ing. 2. Dur ing the 160 kw ex po sure, the in te rior fin ish shall com ply with the fol low ing: BUILDING CODE OF NEW YORK STATE 151

2.1. Flame shall not spread to the outer ex trem ity of the sam ple on any wall or ceil ing. 2.2. Flashover, as de fined in NFPA 286, shall not occur. 3. The to tal smoke re leased through out the NFPA 286 test shall not ex ceed 1,000 m 2. 803.3 Sta bil ity. In te rior fin ish ma te ri als reg u lated by this chap - ter shall be ap plied or oth er wise fas tened in such a man ner that such ma te ri als will not readily be come de tached where sub - jected to room tem per a tures of 200 F (93 C) for not less than 30 min utes. 803.4 Ap pli ca tion. Where these ma te ri als are ap plied on walls, ceil ings or struc tural el e ments re quired to have a fire-re - sis tance rat ing or to be of noncombustible con struc tion, they shall com ply with the pro vi sions of this sec tion. 803.4.1 Di rect at tach ment and furred con struc tion. Where walls and ceil ings are re quired by any pro vi sion in this code to be of fire-re sis tance-rated or noncombustible construction, the interior finish material shall be applied di - rectly against such con struc tion or to fur ring strips not ex - ceed ing 1.75 inches (44 mm) ap plied di rectly against such sur faces. The in ter ven ing spaces be tween such fur ring strips shall be filled with in or ganic or Class A ma te rial or shall be fireblocked at a max i mum of 8 feet (2438 mm) in any di rec tion in ac cor dance with Sec tion 717. 803.4.2 Set-out con struc tion. Where walls and ceil ings are re quired to be of fire-re sis tance-rated or noncombustible con struc tion and walls are set out or ceil ings are dropped dis tances greater than spec i fied in Sec tion 803.4.1, Class A fin ish ma te ri als shall be used ex cept where in te rior fin ish ma te ri als are pro tected on both sides by an au to matic sprin - kler sys tem or at tached to noncombustible back ing or fur - ring strips in stalled as spec i fied in Sec tion 803.4.1. The hang ers and as sem bly mem bers of such dropped ceil ings that are be low the main ceil ing line shall be of noncombustible ma te ri als, ex cept that in Type III and V con struc tion, fire-re tar dant-treated wood shall be per mit - ted. The con struc tion of each set-out wall shall be of fire-re - sis tance-rated con struc tion as re quired else where in this code. 803.4.3 Heavy tim ber con struc tion. Wall and ceil ing fin - ishes of all classes as per mit ted in this chap ter that are in - stalled di rectly against the wood deck ing or plank ing of Type IV con struc tion or to wood fur ring strips ap plied di - rectly to the wood deck ing or plank ing shall be fireblocked as spec i fied in Sec tion 803.4.1. 803.4.4 Ma te rials. An in te rior wall or ceil ing fin ish that is not more than 0.25 inch (6.4 mm) thick shall be ap plied di - rectly against a noncombustible back ing. Exceptions: 1. Class A materials. 2. Ma te rials where the qual i fy ing tests were made with the ma te rial sus pended or furred out from the noncombustible back ing. 803.5 In te rior fin ish re quire ments based on group. In te rior wall and ceil ing fin ish shall have a flame spread in dex not greater than that spec i fied in Ta ble 803.5 for the group and lo - cation designated. Interior wall and ceiling finish materials, other than tex tiles, tested in ac cor dance with NFPA 286 and meet ing the ac cep tance cri te ria of Sec tion 803.2.1, shall be per - mit ted to be used where a Class A clas si fi ca tion in ac cor dance with ASTM E 84 is re quired. 803.6 Textiles. Where used as in te rior wall or ceil ing fin ish ma te ri als, tex tiles, in clud ing ma te ri als hav ing wo ven or nonwoven, napped, tufted, looped or sim i lar sur face, shall com ply with the re quire ments of this sec tion. 803.6.1 Tex tile wall cov er ings. Tex tile wall cov er ings shall have a Class A flame spread in dex in ac cor dance with ASTM E 84 and be pro tected by au to matic sprin klers in - stalled in ac cor dance with Sec tion 903.3.1.1 or 903.3.1.2 or the cov er ing shall meet the cri te ria of Sec tion 803.6.1.1 or 803.6.1.2 when tested in the man ner in tended for use in ac - cordance with NFPA 265 us ing the prod uct mount ing sys - tem, in clud ing ad he sive. 803.6.1.1 Method A test pro to col. Dur ing the Method A pro to col, flame shall not spread to the ceil ing dur ing the 40 kw ex po sure. Dur ing the 150 kw ex po sure, the tex tile wall cov er ing shall com ply with all of the fol low - ing: 1. Flame shall not spread to the outer ex trem ity of the sam ple on the 8-foot by 12-foot (203 mm by 305 mm) wall. 2. The spec i men shall not burn to the outer ex trem ity of the 2-foot-wide (610 mm) sam ples mounted in the cor ner of the room. 3. Burning drop lets deemed ca pa ble of ig nit ing tex - tile wall cov er ings or that burn for 30 sec onds or more shall not form. 4. Flashover, as de fined in NFPA 265, shall not oc cur. 5. The max i mum net in stan ta neous peak heat re lease rate, de ter mined by sub tract ing the burner out put from the max i mum heat re lease rate, does not ex - ceed 300 kw. 803.6.1.2 Method B test pro to col. Dur ing the Method B pro to col, flames shall not spread to the ceil ing at any time dur ing the 40 kw ex po sure. Dur ing the 150 kw ex po - sure, the tex tile wall cov er ing shall com ply with the fol - lowing: 1. Flame shall not spread to the outer ex trem i ties of the sam ples on the 8-foot by 12-foot (203 mm by 305 mm) walls. 2. Flashover, as de scribed in NFPA 265, shall not oc - cur. 803.6.2 Tex tile ceil ing fin ish. Where used as a ceil ing fin - ish, car pet and sim i lar tex tile ma te ri als shall have a Class A flame spread in dex in ac cor dance with ASTM E 84 and be pro tected by au to matic sprin klers. 152 BUILDING CODE OF NEW YORK STATE

GROUP Vertical exits and exit passageways a, b TABLE 803.5 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY k SPRINKLERED l Exit access corridors and other exitways Rooms and enclosed spaces c Vertical exits and exit passageways a, b NONSPRINKLERED Exit access corridors and other exitways Rooms and enclosed spaces c A-1 & A-2 B B C A A d B e A-3 f, A-4, A-5 B B C A A d C B, E, M, R-1, R-4 B C C A B C F C C C B C C H B B C g A A B I-1 B C C A B B I-2 B B B h, i A A B I-3 A A j C A A B I-4 B B B h, i A A B R-2 C C C B B C R-3 C C C C C C S C C C B B C U No restrictions No restrictions For SI: 1 inch = 25.4 mm, 1 square foot = 0.0929 m 2. a. Class C in te rior fin ish ma te ri als shall be per mit ted for wain scot ting or pan el ing of not more than 1,000 square feet of ap plied sur face area in the grade lobby where ap plied di rectly to a noncombustible base or over fur ring strips ap plied to a noncombustible base and fireblocked as re quired by Sec tion 803.4.1. b. In ver ti cal ex its of build ings less than three sto ries in height of other than Group I-3, Class B in te rior fin ish for nonsprinklered build ings and Class C in te rior fin ish for sprinklered build ings shall be per mit ted. c. Re quire ments for rooms and en closed spaces shall be based upon spaces en closed by par ti tions. Where a fire-re sis tance rat ing is re quired for struc tural el e ments, the en clos ing par ti tions shall ex tend from the floor to the ceil ing. Par ti tions that do not com ply with this shall be con sid ered en clos ing spaces and the rooms or spaces on both sides shall be con sid ered one. In de ter min ing the ap pli ca ble re quire ments for rooms and en closed spaces, the spe cific oc cu pancy thereof shall be the gov ern ing fac tor re gard less of the group clas si fi ca tion of the build ing or struc ture. d. Lobby ar eas in Group A-1, A-2 and A-3 oc cu pan cies shall not be less than Class B ma te ri als. e. Class C in te rior fin ish ma te ri als shall be per mit ted in places of as sem bly with an oc cu pant load of 300 per sons or less. f. For churches and places of wor ship, wood used for or na men tal pur poses, trusses, pan el ing or chan cel fur nish ing shall be per mit ted. g. Class B ma te rial is re quired where the build ing ex ceeds two sto ries. h. Class C in te rior fin ish ma te ri als shall be per mit ted in ad min is tra tive spaces. i. Class C in te rior fin ish ma te ri als shall be per mit ted in rooms with a ca pac ity of four per sons or less. j. Class B ma te ri als shall be per mit ted as wain scot ting ex tend ing not more than 48 inches above the fin ished floor in exit ac cess cor ri dors. k. Fin ish ma te ri als as pro vided for in other sec tions of this code. l. Ap plies when the ver ti cal ex its, exit pas sage ways, exit ac cess cor ri dors or exitways, or rooms and spaces are pro tected by a sprin kler sys tem in stalled in ac cor - dance with Sec tion 903.3.1.1 or 903.3.1.2. BUILDING CODE OF NEW YORK STATE 153

803.7 Ex panded vi nyl wall cov er ings. Ex panded vi nyl wall cov er ings shall com ply with the re quire ments for tex tile wall and ceil ing ma te ri als and their use shall com ply with Sec tion 803.6. Exception: Ex panded vi nyl wall or ceil ing cov er ings com - ply ing with Sec tion 803.2 shall not be re quired to com ply with Sec tion 803.1 or 803.6. 803.8 In su la tion. Ther mal and acous ti cal in su la tion shall com ply with Sec tion 719. 803.9 Acous ti cal ceil ing sys tems. The qual ity, de sign, fab ri ca - tion and erec tion of metal sus pen sion sys tems for acous ti cal tile and lay-in panel ceil ings in build ings or struc tures shall conform with generally accepted engineering practice, the provi sions of this chap ter and other ap pli ca ble re quire ments of this code. 803.9.1 Ma te rials and in stal la tion. Acoustical materials com ply ing with the in te rior fin ish re quire ments of Sec tion 803 shall be in stalled in ac cor dance with the man u fac turer s rec om men da tions and ap pli ca ble pro vi sions for ap ply ing interior finish. 803.9.1.1 Sus pended acous ti cal ceil ings. Sus pended acous ti cal ceil ing sys tems shall be in stalled in ac cor - dance with the pro vi sions of ASTM C 635 and ASTM C 636. 803.9.1.2 Fire-re sis tance-rated con struc tion. Acous ti - cal ceil ing sys tems that are part of fire-re sis tance-rated con struc tion shall be in stalled in the same man ner used in the as sem bly tested and shall com ply with the pro vi - sions of Chap ter 7. SECTION 804 INTERIOR FLOOR FINISH 804.1 Gen eral. In te rior floor fin ish and floor cov er ing ma te ri - als shall com ply with this sec tion. Exception: Floors and floor cov er ings of a tra di tional type, such as wood, vi nyl, li no leum or terrazzo, and re sil ient floor cov er ing ma te ri als which are not com prised of fi bers. 804.2 Clas si fi ca tion. In te rior floor fin ish and floor cov er ing ma te ri als re quired by Sec tion 804.5.1 to be of Class I or II ma - terials shall be classified in accordance with NFPA 253. The classification referred to herein corresponds to the classifications de ter mined by NFPA 253 as fol lows: Class I, 0.45 watts/cm 2 or greater; Class II, 0.22 watts/cm 2 or greater. 804.3 Test ing and iden ti fi ca tion. Floor covering materials shall be tested by an ap proved agency in ac cor dance with NFPA 253 and iden ti fied by a hang tag or other suit able method so as to iden tify the man u fac turer or sup plier and style, and shall in di cate the in te rior floor fin ish or floor cov er ing clas si fi - ca tion ac cord ing to Sec tion 804.2. Car pet-type floor cov er ings shall be tested as pro posed for use, in clud ing underlayment. Test re ports con firm ing the in for ma tion pro vided in the man u - fac turer s prod uct iden ti fi ca tion shall be fur nished to the Code Enforcement Of fi cial upon re quest. 804.4 Ap pli ca tion. Combustible materials installed in or on floors of build ings of Type I or II con struc tion shall con form with the re quire ments of this sec tion. Exception: Stages and plat forms con structed in ac cor dance with Sec tions 410.3 and 410.4, re spec tively. 804.4.1 Subfloor construction. Floor sleep ers, bucks and nail ing blocks shall not be con structed of com bus ti ble ma te - ri als, un less the space be tween the fire-re sis tance-rated floor con struc tion and the floor ing is ei ther sol idly filled with ap proved noncombustible ma te ri als or fireblocked in ac cor dance with Sec tion 717, and pro vided that such open spaces shall not ex tend un der or through per ma nent par ti - tions or walls. 804.4.2 Wood fin ish floor ing. Wood fin ish floor ing is per - mit ted to be at tached di rectly to the em bed ded or fireblocked wood sleep ers and shall be per mit ted where ce - mented di rectly to the top sur face of ap proved fire-re sis - tance-rated con struc tion or di rectly to a wood subfloor at tached to sleep ers as pro vided for in Sec tion 804.4.1. 804.4.3 In su lating boards. Com bus ti ble in su lat ing boards not more than 0.5-inch (12.7 mm) thick and cov ered with ap proved fin ished floor ing are per mit ted, where at tached di - rectly to a noncombustible floor as sem bly or to wood subflooring at tached to sleep ers as pro vided for in Sec tion 804.4.1. 804.5 Interior floor finish requirements. In all oc cu pan cies, in te rior floor fin ish in ver ti cal ex its, exit pas sage ways, exit ac - cess cor ri dors and rooms or spaces not sep a rated from exit ac - cess cor ri dors by full-height par ti tions ex tend ing from the floor to the un der side of the ceil ing shall with stand a min i mum crit i - cal ra di ant flux as spec i fied in Sec tion 804.5.1. 804.5.1 Min i mum crit i cal ra di ant flux. In te rior floor fin - ish in ver ti cal ex its, exit pas sage ways and exit ac cess cor ri - dors shall not be less than Class I in Groups I-2 and I-3 and not less than Class II in Groups A, B, E, H, I- 4, M, R-1, R-2 and S. In all other ar eas, the in te rior floor fin ish shall com ply with the DOC FF-1 pill test (CPSC 16 CFR, Part 1630). Exception: Where a build ing is equipped through out with an au to matic sprin kler sys tem in ac cor dance with Sec tion 903.3.1.1, Class II ma te ri als are per mit ted in any area where Class I ma te ri als are re quired and ma te ri als com ply ing with DOC FF-1 pill test (CPSC 16 CFR, Part 1630) are per mit ted in any area where Class II ma te - ri als are re quired. [F] SECTION 805 DECORATIONS AND TRIM 805.1 Gen eral. In oc cu pan cies of Groups A, E, I, R-1 and dor - mi to ries in Group R-2, cur tains, drap er ies, hang ings and other decorative materials suspended from walls or ceilings shall be flame re sis tant in ac cor dance with Sec tion 805.2 and NFPA 701 or noncombustible. In Groups I-1 and I-2, com bus ti ble dec o ra tions shall be flame re tar dant un less the dec o ra tions, such as pho to graphs and paint ings, are of such lim ited quan ti ties that a haz ard of fire 154 BUILDING CODE OF NEW YORK STATE

de vel op ment or spread is not pres ent. In Group I-3, com bus ti - ble dec o ra tions are pro hib ited. 805.1.1 Noncombustible ma te ri als. The per mis si ble amount of noncombustible dec o ra tive ma te rial shall not be limited. 805.1.2 Flame-re sis tant ma te ri als. The per mis si ble amount of flame-resistant decorative materials shall not ex - ceed 10 per cent of the ag gre gate area of walls and ceil ings. Exception: In au di to ri ums of Group A, the per mis si ble amount of flame-resistant decorative material shall not ex ceed 50 per cent of the ag gre gate area of walls and ceil - ings where the build ing is equipped through out with an automatic sprinkler system in accordance with Section 903.3.1.1 and the ma te rial is in stalled in ac cor dance with Sec tion 803.4. 805.2 Acceptance criteria and reports. Where re quired to be flame re sis tant, dec o ra tive ma te ri als shall be tested by an ap - proved agency and pass Test 1 or 2, as ap pro pri ate, de scribed in NFPA 701 or such ma te ri als shall be noncombustible. Re ports of test re sults shall be pre pared in ac cor dance with NFPA 701 and fur nished to the code en force ment of fi cial upon re quest. 805.3 Foam plas tic. Foam plas tic used as trim in any oc cu - pancy shall com ply with Sec tion 2604.2. 805.4 Pyroxylin plas tic. Im i ta tion leather or other ma te rial con sist ing of or coated with a pyroxylin or sim i larly haz ard ous base shall not be used in Group A oc cu pan cies. 805.5 Trim. Ma te rial used as in te rior trim shall have min i mum Class C flame spread and smoke-de vel oped in dexes. Com bus - ti ble trim, ex clud ing hand rails and guard rails, shall not ex ceed 10 per cent of the ag gre gate wall or ceil ing area in which it is located. BUILDING CODE OF NEW YORK STATE 155

156 BUILDING CODE OF NEW YORK STATE