Kinro Metal, Vinyl, Flush Mount and Recessed Fin Windows OEM INSTALLATION MANUAL

Similar documents
Kinro Metal, Vinyl, Flush mounted and Recessed Fin Windows (HUD) OEM INSTALLATION MANUAL

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Lend-A-Hand OEM INSTALLATION MANUAL

RV Entry Door OEM INSTALLATION MANUAL

Ramp Door OEM INSTALL MANUAL

Installation Recommendations for Finless Frame Doors

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Tools required by installer: Materials required by installer:

Vinyl Windows Manufactured by VPI Quality Windows

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

All Window Installation Instruction

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

Sun Windows General Information New Construction Hinged Door Installation Instructions

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

TARGA 7100 SINGLE HUNG INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

HR175 Sash Replacement Kit Installation Instructions

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

Flashing Materials. Rough Opening Preparation

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Installation of Fiberglass Windows

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

TARGA 7200 HORIZONTAL ROLLER INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Solidstep GEN 2 OEM INSTALL MANUAL. Rev: Page 1

SolidStep 3.0 OEM INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS.

SENTINEL SERIES 110 SINGLE HUNG WINDOWS

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

Integrity Polygon and Round Top Installation and Finishing Instructions

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

Curtain Wall Installation Guide

RV ENTRY DOOR REMOVAL AND SHIPPING BLOCK INSTALLATION AND ALIGNMENT

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Installation Guide. for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

Vinyl Windows and Doors Manufactured by Pella Corporation

TARGA 7300 CASEMENT INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

Sash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Eagle clad double-hung window installation instructions

window installation Guide wood FRaMinG New Construction

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

How To Install Windows: Nail-Fin Application

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

Installation Instructions

INSTALLATION INSTRUCTIONS for Custom and Premium Pocket Windows (JII022) IMPORTANT INFORMATION AND GLOSSARY SAFETY AND HANDLING

Sliding Glass Door Assembly and Installation Guide

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

Installation Instructions for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Victory Step OEM INSTALLATION MANUAL

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

United States 32" Features and Benefits of WEATHERMATE Sill Pan

STACKING MULTI-SLIDE DOOR SYSTEM

RECREATIONAL VEHICLE DOOR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Picture Window Rough Opening Installation with Sheathing Intact with Brickmould Tools: (Not supplied by manufacturer) Fig. 0-1

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.

Heavy Wall Applied Stop Tube Frame and Door Installation

Vinyl Windows and Doors

Installation Guide for Architectural Wood Hinged Windows

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS.

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

Before installation, check your local and state requirements for this type of install.

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

Contemporary 3 Panel Classic 5 Panel French Panel

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Installation Instructions

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

8/7/ HP SWING DOOR INSTALLATION INSTRUCTIONS

Casement/ Casement Picture Pocket Installation (Interior) Tools: (Not Provided by Manufacturer) Fig Supplies: (Not Provided by Manufacturer)

GENERAL INSTALLATION GUIDELINES

Transcription:

Kinro Metal, Vinyl, Flush Mount and Recessed Fin Windows OEM INSTALLATION MANUAL

TABLE OF CONTENTS Introduction 2 Safety Requirements 2 Fasteners 3 Preparation 3 Rough Opening Preparation 3 Resources Required 3 Tools Required 3 Window Installation 4 Post Installation 7 Replacing Existing Windows 7 Additional Information Sources 7 Introduction These installation instructions are recommendations only. Local building codes may impose additional requirements, and those codes may supersede these instructions. Additional resources include: AAMA 2400 - Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure. FMA/AAMA 100 - Standard Practice for the Installation of windows with Flanges or Mounting Fins in Wood Frame Construction. (Windows specifically designed for installations subject to extreme wind/water climate exposure. Lippert Components makes no warranty, expressed or implied, with respect to these or any other third party instructions. Lippert shall not be liable for any damage or liability that may arise in connection with any product installation not performed by Lippert. Safety Requirements The "WARNING" symbol above is a sign that an installation procedure has a safety risk involved and may cause death or serious injury if not performed safely and within the parameters set forth in this manual. Always wear eye protection when performing this installation procedure. Other safety equipment to consider would be hearing protection, gloves, and possibly a full face shield, depending on the nature of the installation procedure. Moving parts can pinch, crush or cut. Keep clear and use caution. Rev: 07.10.18 Page 2 CCD-0001571

Resources Required Tools Required Level Tape Measure Caulking Gun Hammer Screw Gun Gunnable Sealant Putty Tape Fasteners Fasteners should be selected to ensure compliance with applicable building codes. Consideration should be given to wind loads, temperature variations, and other site conditions. Screws, nails or staples may be used as fasteners for your installation into wood framing. Only screws should be used for window installation into metal home framing. The fastener must penetrate the framing at least one (1") inch, allowing for exterior sheathing. Fasteners for use in wood framing include: 6D smooth shank nails (1 1 2" min.) 6D ring shank nails 16 Gauge adhesive coated staples, 7/16" crown #8 pan head screw NOTE: Any fastener, either screw, nail, or staple that is left exposed to the weather should be plated or otherwise coated to prevent corrosion. It is suggested that one fastener be placed in or near every prepunched mounting hole for maximum fastening strength. Fasteners should be spaced a maximum of 4" from mounting flange corners and a maximum of 4 1/2" on center between fasteners around the perimeter of the mounting flange. The fastener location from the mounting flange edge should be no less than 9 64" for all products. NOTE: Actual fastening methods and materials may be dictated by the project plans or applicable local codes. Methods may also be as directed by an Architect or Professional Engineer. Site specific requirements may be enforced by the Florida Building Code or Texas Department of Insurance. Consult the FBC and/or TDI website for anchorage specifics when applicable. Preparation Rough Opening Preparation 1. Opening for windows should be framed in accordance with the standards for size of window used in order not to apply any loading to the window which may hamper its operation. The prepared rough opening should allow a minimum 1/8" clearance on each side, the head and the sill, including the thickness of pre-finished paneling, shims, liners, etc. where used. 2. Window rough opening should be level, plumb and square: check width, height, and diagonal measurements to assure the opening is level, plumb and square. It is recommended that the sill of the rough opening be straight and level. Bowed or warped sill framing members can result in a crowned sill of the window. 3. Make certain all window mounting surfaces are securely fastened and flat around the perimeter of the rough opening. Check the opening for correct size per step 1 above. 4. Weather Resistance: Prepare the rough opening in accordance with prevailing codes. A number of solutions exist that are appropriate for site location and it is not the intent of Lippert to advocate only one. Flashing guidelines for openings can be found in the current version of AAMA 2400 and FMA/ AAMA 100, if the flashing system is used. Rev: 07.10.18 Page 3 CCD-0001571

If the exposed surfaces of the rough inside opening are to be trimmed out with pre-finished paneling, it must be done in such a manner so as not to distort or twist the window frame members and make the operating sash tight or inoperable. If interior trim is installed prior to window installation make sure that enough room is left to allow the window to fully seat against the exterior wall surface. Do not obstruct tilting sash operation or locking mechanisms with inside trim, wood molding, etc. For vinyl windows leave an appropriate gap between the edge of the siding material and the window frame to allow for siding expansion and contraction. For vinyl horizontal sliding & fixed windows 72" in width and greater, Lippert recommends a 1" min. sill support or angle bracket support, dependent on exterior home finish, to be installed underneath the projected frame sill on the outside. The use of any appurtenance system not approved for the Egress window or any alterations of an approved appurtenance system voids the windows certification. The operating instructions and certification label are a permanent part of the Egress unit and must not be removed. Window Installation To avoid damage to the seal between the glass and the window glazing member, power drivers should be adjusted so as not to cause excessive dimpling of the window flanges. Careless mounting procedures could negate window certification and Lippert warranty. NOTE: Installing vinyl windows with vinyl nailing fins on top of vertical or horizontal metal siding will void all warranties. Vinyl nailing fins will be damaged and leaks may occur. Aluminum mounting flanges are available specifically for this condition. 1. Apply a quality, non-hardening, water resistant sealant to the back of the window mounting flanges in order to provide a water tight seal with the homes weather-proof envelope. Suitable types include 1/8" thick putty or butyl tape or a 1/4" bead of gunnable sealant. The tape or caulk bead should be applied centered over the mounting holes on the back of the window mounting flange. For vinyl windows, do not use a sealant that contains solvents which may chemically attack vinyl. The use of foam tapes is not recommended for vinyl window installation. 2. Do not remove any shipping clips if provided on the window series being installed. Always keep operating sash closed and locked during installation. 3. Always handle windows with care. Always pick them up by both side jambs using both hands. Never pick up and handle windows by the header only, sill only or by one side jamb only. This can damage the window and possibly rupture the glazing seal and/or joint caulking, resulting in a possible leak. NOTE: Double hung windows require extra care during installation. Double hung windows do not have fixed glass, which offers additional frame stability. 4. Carefully insert the window into the opening. Center the window in the rough opening with the sill of the window resting on the sill of the rough opening. Press the mounting flange against the mounting surface. NOTE: All fasteners should be driven straight into the mounting flange. See Fasteners section for fastener information. Pattern of Figure 1 applies to both single pane and double hung windows. 5. The following sequence of fastener installation is suggested. Refer to Figures 1-3 for a visual guide to fastener placement of assorted window types. A. Drive the first fastener at approximately the center of either the left or right vertical frame jamb mounting flange (Fig. 1A). B. Moving across, drive the second fastener on the opposite vertical mounting flange at the approximate center (Fig. 1B). Rev: 07.10.18 Page 4 CCD-0001571

NOTE: When installing windows, check the window sill for straightness. If the window sill is crowned, apply light pressure at the center of window sill until it is level. While holding the sill level, drive the third fastener into the center of the sill flange. C. Drive the third fastener at the center of the sill flange (Fig. 1C). D. Drive the fourth fastener at the center of the head flange (Fig. 1D). E. Beginning with one of the above already installed fasteners, install remaining fasteners to the end of each frame member. Repeat this step until all the fasteners have been inserted from the center of the vertical frame jamb outward to both ends of each member. F. Finish installing the fasteners from the center of the frame head and sill outward to the ends of each member (Fig. 2). This sequence of fastener installation applies to both vertical (Fig. 1) and horizontal (Fig. 2 and 3) sliding windows, flush mount and recessed fin mount, for both metal and vinyl windows. Fig. 1 D A B C VERTICAL SECTION LAP FIN WITH VINYL SIDING HORIZONTAL SECTION LAP FIN WITH VINYL SIDING HORIZONTAL SECTION FLUSH FIN Rev: 07.10.18 Page 5 CCD-0001571

Fig. 2 D After initial fasteners are placed, run all other fasteners from one fastener to the end of the nailing fin or mounting flange. A B C After initial fasteners are placed, run all other fasteners from one fastener to the end of the nailing fin or mounting flange. D Fig. 3 D A B C C Rev: 07.10.18 Page 6 CCD-0001571

Post Installation Windows should be checked after installation to make sure that all moving panels, mechanisms, latches, and other hardware function properly. All shipping clips must be removed prior to operation of the window. All windows should be checked for out-of-square bowing of frame members. If any of the above problems are present, window should be removed and re-installed properly. NOTE: The window's exterior mounting flanges should be checked after the installation to assure an all-weather seal. It is recommended to seal the outside top of window (full width) with a good quality sealant for additional insurance and/or flash after installation in accordance with AAMA 2400 or FMA/AAMA 100 or instructions published by the manufacturer of the flashing system in use. Replacing Existing Windows 1. Homes built prior to 1978 may contain lead based paints. Consult www.epa.gov/lead for guidelines on removal of old products and management of lead paint. 2. Guidelines for disposal and/or recycling of old products can be found at www.epa.gov/recycle. Additional Information Sources Additional information about this product can be obtained from www.lci1.com/support or by downloading the free mylci app. The app is available on itunes for iphone and ipad and also on Google Play for Android users. itunes, iphone, and ipad are registered trademarks of Apple Inc. Google Play and Android are trademarks of Google Inc. Google Inc. Rev: 07.10.18 Page 7 CCD-0001571

The contents of this manual are proprietary and copyright protected by Lippert Components, Inc. ( LCI ). LCI prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized LCI representative has been provided. Any unauthorized use shall void any applicable warranty. The information contained in this manual is subject to change without notice and at the sole discretion of LCI. Revised editions are available for free download from lci1.com. Please recycle all obsolete materials. For all concerns or questions, please contact Lippert Components, Inc. Ph: (574) 537-8900 Web: lci1.com Email: customerservice@lci1.com