MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

Similar documents
Manholes Table of Contents

DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION MANHOLES

Pipe Product Catalog Table of Contents

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

PART MATERIALS. Section Fencing Materials. Description

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

Standard Specifications

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

Anti-Trust Statement

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

SECTION 39 - MANHOLES TABLE OF CONTENTS

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

APPENDIX FENCE GENERAL NOTES

Midwest Roadside Safety Facility

SECTION SAND CUSHION TERRAZZO FLOORING

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846

SECTION MANHOLES

CONCRETE MANHOLES.

A. Extent of structural precast concrete work is shown on drawings and in schedules.

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION METAL FABRICATIONS

This specification describes the minimum requirements for piping systems for the following service:

Plastibeton Trench System. Installation Packet

Plastibeton Trench System. Installation Packet

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

GENERAL ISOMETRIC LAYOUT

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

Customer Requirements Commercial Secondary Service

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

GENERAL ELEVATION SECTION A-A

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

1.1 RELATED DOCUMENTS

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

SUBSTATION SECURITY WALL INSTALLATION MANUAL

Digitally Signed 06/02/2015

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

This specification describes the minimum requirements for piping systems for the following service:

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

MULE-HIDE PRODUCTS CO., INC FASTENER GUIDELINES

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser

STANDARD BID ITEM NUMBERS

Installation Instructions

Current Standard Plates including Transmittal Letters are available on the web at:

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas

Hardened Structures Hardened Shelters, LLC. Explosion Resistant Pre-hung Sealed Blast Door

STEEL PIPE GUIDERAIL 01/01/

ALL SEASON PATIO COVER

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas

Thread protection accessories are installed at the MODIX production factory and delivered with couplers.

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Thru Wall Floor Seals For New Installation

EXTERIOR BUILDING, ROOFING, AND SITE IMPROVEMENTS

AUXILIARY FRAMING AND ACCESSORIES

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

STRUCTURAL ATTACHMENTS

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX

Concealed Thru-Roof Assemblies

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

TYPE 4-C TYPE 6 TYPE 7 TYPE 8

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER

STRUCTURES FOR SANITARY AND STORM SEWERS

SECTION G ESTIMATE OF QUANTITIES

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

General Information...SA1-SA4

Current Standard Plates including Transmittal Letters are available on the web at:

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

24" Dia. 36" Dia. WE BUILD CONFIDENCE

SECTION PRECAST CONCRETE STRUCTURES

Appendix C Construction Details

UNIVERSAL BASES. #60UB - Universal Mounting Base. Same as above for 1/2 inside threads.

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

Section 914. JOINT AND WATERPROOFING MATERIALS

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

PIP STF05121 Anchor Fabrication and Installation Into Concrete

Transcription:

MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements........................................... MH-1 Precast Tub-Type Manholes MH 310.1 Precast Tub-Type Manholes......................................... MH-3 Precast Manhole Neck Detail MH 318.1 Precast Manhole Neck Detail........................................ MH-5 4' x 6' x 7' Manhole Traffic Loading MH 320.1 4' x 6' x 7' Manhole Traffic Loading................................. MH-7 4' x 8' x 7' Manhole Traffic Loading MH 325.1 4' x 8' x 7' Manhole Traffic Loading................................ MH-11 6' x 8' x 7' Manhole Traffic Loading MH 330.1 6' x 8' x 7' Manhole Traffic Loading................................ MH-17 7' x 7' x 7' Manhole Traffic Loading MH 335.1 7' x 7' x 7' Manhole Traffic Loading................................ MH-21 6' x 10' x 7' Manhole Traffic Heavy Loading MH 340.1 6' x 10' x 7' Manhole Traffic Heavy Loading......................... MH-25 Manhole Neck Details 27" Opening MH 350.1 Manhole Neck Details 27" Opening................................ MH-29 Table of Contents SCE Public UGS MH MH-i

MH 300 Manholes Requirements Scope MH 300.1 Manholes Requirements 1.0 General 1.1 Manholes which have acceptable precast counterparts are shown on the working drawings (List of Materials) by item number and the types of manholes approved for each item number are listed below. Other manholes are listed by drawing number. Unless otherwise noted on the working drawings, any of the structures covered by a particular item number are acceptable. 1.2 All manhole installations to be watertight. Standard manhole cover/frame size is 30". Manhole cover to be cast-iron for traffic loading, and RPM for parkway loading. Manhole entry covers shall be bolted closed and any lift holes sealed. 2.0 Poured Manholes 2.1 Each manhole shall include accessories and facilities in conformance with the requirements set forth in the drawings, specifications, schedules, and tabulations referred to below: A. Concrete and reinforcement as shown on the drawing and in conformance with GI 020. B. Opening cover as shown on structure drawing or as modified on the working drawing (shown on the List of Materials). C. Conduit entrance.................................................. CD 130 D. Inserts.................................................. AC 720 and AC 722 E. Sump........................................................... AC 710 F. Ground wires..................................................... AC 700 G. Neck........... MH 350 (page MH 29) (See MH 318 (page MH 5) for precast concrete) H. Ladders (when required)............................................. AC 740 3.0 Precast Manholes 3.1 Each precast manhole shall be manufactured in conformance with the requirements as referred to below: A. Manholes shall be manufactured and installed to the requirements as set forth in GI 030. B. Each manhole shall include accessories and facilities as required in poured manholes. (Some small construction variations have been allowed the precast concrete manufacturers.) C. Manholes shall be placed on a 6-inch minimum thickness of mechanically compacted crushed aggregate base (3/4-inch maximum). D. All walls and ceilings to be painted white. Manholes Requirements SCE Public UGS MH 300 MH 1

E. Maximum placement depth is 4 foot, measured from grade to top outside surface of manhole and under conditions assumed in GI 030. Contact Division Underground Planning Supervisor if greater depth is required. Item No. Nominal Size Table MH 1: Manholes Field Construction Drawings Precast Concrete Manufacturers a/ Jensen Precast Utility Vault Co. M-1 4' x 6'-6" x 5'-6" K466-DM66-11 M-3 4' x 6'-6" x 7' K466-DM84-11 ED466-84MH M-2 4' x 6' x 7' MH 320 (page MH 7) M-4 4' x 8' x 7' MH 325 (page MH 11) M-5 4'-6" x 8'-6" x 7' K4686-DM84-11 ED4686-84MH M-6 6' x 8' x 7' MH 330 (page MH 17) K68-DM84-11 ED68-84MH M-7 6' x 10' x 7' K610-DM84-11P ED610-84MH M-8 6' x 10' x 7' (T) MH 340 (page MH 25) K610-DM84-11T ED610-84MH-Traffic M-9 7' x 7' x 7' MH 335 (page MH 21) Special Order M-10 b/ 5' x 10'-6" x 7' K5106-FM84-11 ED5106-84MH M-11 b/ 6' x 12' x 7' K612-FM84-11 ED612-84MH a/ Standard style enclosures are listed. For intercept part numbers add "-INT" to the end of the standard part number. b/ Tub Style For reference only Table MH 2: Manhole Material Codes Nominal Size Material Code 4' x 6'-6" x 5'-6" Pending 4' x 6'-6" x 7' Pending 5' x 10'-6" x 7' Pending 6' x 12' x 7' Pending MH 300 UGS MH 2 Manholes Requirements SCE Public

MH 310 Precast Tub-Type Manholes Scope MH 310.1 Precast Tub-Type Manholes Figure MH 1: Precast Tub-Type Manholes Width Length Height 5' 10'-6" 7' 6' 12' 7' 36" Manhole Clear Opening Joint Sealer See GI 030 Conduit Terminators per CD 142 (Typical All Manufacturers) Sump 1.0 Excavation Size: Consult manufacturer s installation guides for exact excavation dimensions for each structure size. 2.0 UGS Reference: GI 030 General Specification for Precast Structures GI 035 Allowable Tolerances for Installed Precast Structures CD 142 Conduit Entrance MH 318 (page MH 5) Precast Manhole Neck Detail AC 711 Sump Drain and Detail AC 740 Ladders Precast Tub-Type Manholes SCE Public UGS MH 310 MH 3

Notes: 1. Conduit terminators to be generally located as shown on CD 142. Standard conduit entrance shall be a flatwall design. Slight variations by manufacturers may be allowable with Company approval. 2. Tub-type structures shall be furnished with 1/2" threaded bronze grounding inserts, as shown on VA 411. 3. Inside walls and ceiling to be painted white MH 310 UGS MH 4 Precast Tub-Type Manholes SCE Public

MH 318 Precast Manhole Neck Detail Scope MH 318.1 Precast Manhole Neck Detail Figure MH 2: Precast Manhole Neck Detail See Note 6 Cover and Frame per FC 621 Dry pack grout under frame and cover after ring is set to grade Adjustable Anchors (Four required) 30" Clear Opening 36" 12" Joint Sealant Notes: 1. See AC 740 for ladder installation (when required). 2. Various size grade rings available (3", 6", 12", etc.). See MH 318 (page MH 6). 3. Reinforcement designed for H-20 bridge loading. 4. Standard manhole cover/frame size is 30" 5. RPM cover is to be used if in nonvehicular traffic conditions. 6. Bonding adhesive per GI 030, Paragraph E. Roof Line Grade Ring See Note 2 Table MH 3: Replacement 30" Diameter Manhole Neck and Cover, Cast Iron Traffic Manufacturer Part Number Material Code Jensen Precast K36-MN14-11T Pending Utility Vault A-1106 frame and cover Pending Precast Manhole Neck Detail SCE Public UGS MH 318 MH 5

Item Number Extension Height a/ Jensen Precast (formerly Brooks Products) Table MH 4: Manhole Grade Rings Manufacturers Numbers Jensen Precast a/ Utility Vault Co. Material Code MX-1 3 inch MN36-R3 ED-3603-GR Pending MX-2 6 inch MN36-R6 ED-3606-GR Pending MX-3 12 inch MN36-R12 ED-3612-GR Pending MH 318 UGS MH 6 Precast Manhole Neck Detail SCE Public

MH 320 4' x 6' x 7' Manhole Traffic Loading Scope MH 320.1 4' x 6' x 7' Manhole Traffic Loading Figure MH 3: 4' x 6' x 7' Manhole Traffic Loading Cover N1 T5 T1 A T5 B B T4 T6 T1 T6 Section A-A MH 350 (page MH-29) Neck Detail 4 Spaces O.C. 16" 6'-0" 7'- Roof Plan 2" T4 T6 2 Spaces O.C. 12" T2 A 5 Spaces O.C. 4'-0" 5'- T2 Table MH 5: Reinforcing Schedule 4' x 6' x 7' Manhole Traffic Loading Cover Mark Quantity Length Long Leg Size Wt. Lbs. T1 16 4'-10" 29" V. #5 81 T2 24 3'- 23" H. #5 92 10 4'-0" Straight #5 42 T4 6 3'- 29" V. #5 21 T5 8 4'-5" 29" V. #5 37 T6 4 6'-0" Straight #5 25 N1 1 110" Welded Wire Fabric 2" x 2" 12 Ga. Min. 3 T6 T1 T5 Section B-B Notes: 1. Refer to MH 300 (page MH 1) for reference drawings giving installation details, schedules, and general requirements for manhole structures and accessories. See working drawings for additional details of neck, conduit bank, etc. Excavation Concrete Total Rebar 14.2 Cu. Yds. 7.06 Cu. Yds. 781 Lbs. FOR REFERENCE ONLY T6 T2 4' x 6' x 7' Manhole Traffic Loading SCE Public UGS MH 320 MH 7

Figure MH 4: 4' x 6' x 7' Manhole Traffic Loading Wall 6" 4 Spaces 1 O.C. 6" C Section C-C 7'- 6'-0" 8 Spaces O.C. Side Wall Notes: 1. All side steel clear from outside surface. Table MH 6: Reinforcing Schedule 4' x 6' x 7' Manhole Traffic Loading Wall 12" 7' 0" 8' 10" 10" Mark Quantity Length Long Leg Size Wt. Lbs. 30 7'-0" Straight #3 79 10 6'-0" Straight #3 23 10 4'-0" Straight #3 15 20 2'-10" 17" H. #3 22 C D Section D-D 5'- 4'-0" 5 Spaces O.C. End Wall Vent When Req'd. FOR REFERENCE ONLY D MH 320 UGS MH 8 4' x 6' x 7' Manhole Traffic Loading SCE Public

5'- F B5 AC 710 Sump Detail E Figure MH 5: 4' x 6' x 7' Manhole Traffic Loading Floor 4 Spaces @ O.C. 6'-0" 7'- E B4 Floor Plan Section F-F B4 B4 B4 Notes: 1. All floor and roof steel 2" minimum clear from outside surfaces. All side steel minimum clear from outside surfaces. Table MH 7: Reinforcing Schedule 4' x 6' x 7' Manhole Traffic Loading Floor Mark Quantity Length Long Leg Size Wt. Lbs. 28 4'- 29" H. #5 126 30 3'- 23" H. #5 115 11 4'-0" Straight #5 46 B4 8 6'-0" Straight #5 50 B5 4 1'-9" Straight #5 7 2 Spaces @ O.C. 10" F 2" B4 B4 Section E-E FOR REFERENCE ONLY 4' x 6' x 7' Manhole Traffic Loading SCE Public UGS MH 320 MH 9

MH 325 4' x 8' x 7' Manhole Traffic Loading Scope MH 325.1 4' x 8' x 7' Manhole Traffic Loading Figure MH 6: 4' x 8' x 7' Manhole Traffic Loading Roof See MH 350 (page MH 29) N1 T1 T6 T4 2" T6 T2 12" T2 T1 T2 T6 T5 T6 T2 Section A-A Clear Section B-B T1 A B 9'- 8'-0" 5 Spaces O.C. 2 T6 T4 T6 3 Spaces O.C. A 5 Spaces O.C. Notes: 1. Refer to MH 300 (page MH 1) for reference drawings giving installation details, schedules, and general requirements for manhole structures and accessories. See working drawings for additional details of neck, conduit banks, etc. 4'-0" 5'- Excavation Concrete Total Rebar 18.11 Cu. Yds. 8.4 Cu. Yds. 975 Lbs. T5 T1 B T6 T4 T6 T2 Roof Plan Table MH 8: Reinforcing Schedule 4' x 8' x 7' Manhole Traffic Loading Roof Mark Quantity Length Long Leg Size Wt. Lbs. T1 20 4'-10" 29" V. #5 101 T2 28 3'- 23" H. #5 110 4' x 8' x 7' Manhole Traffic Loading SCE Public UGS MH 325 MH 11

Table MH 8: Reinforcing Schedule 4' x 8' x 7' Manhole Traffic Loading Roof (Continued) Mark Quantity Length Long Leg Size Wt. Lbs. 12 4'-0" Straight #5 51 T4 8 3'- 29" V. #5 28 T5 8 5'-3" 3 H. #5 45 T6 4 8'-0" Straight #5 34 N1 1 110" Welded Wire Fabric 2" x 2" 12 Ga. Min. 3 MH 325 UGS MH 12 4' x 8' x 7' Manhole Traffic Loading SCE Public

Figure MH 7: 4' x 8' x 7' Manhole Traffic Loading Wall Typ. Section C-C Section D-D 9'- 8'-0" 11 Spaces O.C. 5'- 4'-0" 5 Spaces O.C. 12" C 6" C D Vent When Req'd. D 4 Spaces 1 O.C. 9' 0" 6" 12" Side Wall End Wall 4' x 8' x 7' Manhole Traffic Loading SCE Public UGS MH 325 MH 13

S Table MH 9: Reinforcing Schedule 4' x 8' x 7' Manhole Traffic Loading Wall Mark Quantity Length Long Leg Size Wt. Lbs. 36 7'-0" Straight #3 95 10 8'-0" Straight #3 31 10 4'-0" Straight #3 15 20 2'-10" 17" H. #3 22 Notes: 1. All side steel clear from outside surface. MH 325 UGS MH 14 4' x 8' x 7' Manhole Traffic Loading SCE Public

Figure MH 8: 4' x 8' x 7' Manhole Traffic Loading Floor 9'- 8'-0" B4 B4 CL. Section E-E 5' 4' 0" 2" CL. B4 B4 2" CL. Section F-F 5 Spaces O.C. F E E B4 5 Spaces O.C. F B4 Floor Plan 4' x 8' x 7' Manhole Traffic Loading SCE Public UGS MH 325 MH 15

All floor and roof steel 2" min. clear from outside surfaces. All side steel min. clear from outside surfaces. Table MH 10: Reinforcing Schedule 4' x 8' x 7' Manhole Traffic Loading Floor Mark Quantity Length Long Leg Size Wt. Lbs. 36 4'- 29" H. #5 176 36 3'- 23" H. #5 138 14 4'-0" Straight #5 59 B4 8 8'-0" Straight #5 67 MH 325 UGS MH 16 4' x 8' x 7' Manhole Traffic Loading SCE Public

MH 330 6' x 8' x 7' Manhole Traffic Loading Scope MH 330.1 6' x 8' x 7' Manhole Traffic Loading Figure MH 9: 6' x 8' x 7' Manhole Traffic Loading Roof T1 T4 N1 T2 T6 T2 T1 A T5 T1 Notes: 1. Refer to MH 300 (page MH 1) for reference drawings giving installation details, schedules, and general requirements for manhole structures and accessories. See working drawings for additional details of neck, conduit bank, etc. Excavation Concrete Total Rebar B B T6 T6 T6 25.3 Cu. Yds. 11.3 Cu. Yds. 1,857 Lbs. Section A-A MH 350 (page MH-29) 12" 4 Spaces O.C. 8'-0" 9'- Roof Plan T4 T6 T6 12" 12" T2 A T2 T2 8 Spaces O.C. 6'-0" 7'- Section B-B FOR REFERENCE ONLY T1 T5 T6 6' x 8' x 7' Manhole Traffic Loading SCE Public UGS MH 330 MH 17

2. Table MH 11: Reinforcing Schedule 6' x 8' x 7' Manhole Traffic Loading Roof Mark Quantity Length Long Leg Size Wt. Lbs. 3. 4. T1 20 5'-6" 33" V. #6 166 T2 38 4'- 27" H. #6 247 12 6'-0" Straight #6 109 T4 8 4'- 33" V. #6 57 T5 14 5'-9" 33" H. #6 121 T6 8 8'-0" Straight #6 97 N1 1 12" x 110" Welded Wire Fabric 2" x 2" 12 Ga. Min. 3 FOR REFERENCE ONLY MH 330 UGS MH 18 6' x 8' x 7' Manhole Traffic Loading SCE Public

Figure MH 10: 6' x 8' x 7' Manhole Traffic Loading Wall Section C-C Section D-D C 9'- 8'-0" 11 Spaces O.C. Side Wall Notes: 1. All side steel clear from outside surface. 6" 4 Spaces 1 O.C. 7'-0" 9'-0" 6" 12" 12" Table MH 12: Reinforcing Schedule 6' x 8' x 7' Manhole Traffic Loading Wall Mark Quantity Length Long Leg Size Wt. Lbs. 42 7'-0" Straight #3 111 10 8'-0" Straight #3 31 10 6'-0" Straight #3 23 20 2'-10" 17" #3 22 C D 7'- 6'-0" 8 Spaces O.C. Vent When Req'd. End Wall FOR REFERENCE ONLY D 6' x 8' x 7' Manhole Traffic Loading SCE Public UGS MH 330 MH 19

Figure MH 11: 6' x 8' x 7' Manhole Traffic Loading Floor B4 E 7'- 6'-0" 8 Spaces O.C. Section E-E F B4 AC 710 B4 5 Spaces O.C. 8'-0" 9'- F Floor Plan Notes: 1. All floor and roof steel 2" minimum clear from outside surfaces. All side steel minimum clear from outside surfaces. Table MH 13: Reinforcing Schedule 6' x 8' x 7' Manhole Traffic Loading Floor Mark Quantity Length Long Leg Size Wt. Lbs. 42 5'- 29" H. #6 337 42 4'- 23" H. #6 273 14 6'-0" Straight #6 127 B4 11 8'-0" Straight #6 133 B4 E Section F-F FOR REFERENCE ONLY B4 12" MH 330 UGS MH 20 6' x 8' x 7' Manhole Traffic Loading SCE Public

MH 335 7' x 7' x 7' Manhole Traffic Loading Scope MH 335.1 7' x 7' x 7' Manhole Traffic Loading Figure MH 12: 7' x 7' x 7' Manhole Traffic Loading Roof 8'- 7'-0" 12" A T4 T1 T1 T4 3" T1 T4 T2 Roof Plan Notes: 1. Refer to MH 300 (page MH-1) for reference drawings giving installation details, schedules, and general requirements for manhole structures and accessories. See working drawings for additional details of neck, conduit bank, etc. Section A-A T2 T1 T4 T2 T2 MH 350 (page MH-29) FOR REFERENCE ONLY N1 A 3" 13 Spaces 6" O.C. Excavation Concrete Total Rebar 25.7 Cu. Yds. 10.5 Cu. Yds. 2,468 Lbs. 7' x 7' x 7' Manhole Traffic Loading SCE Public UGS MH 335 MH 21

Table MH 14: Reinforcing Schedule 7' x 7' x 7' Manhole Traffic Loading Roof Mark Quantity Length Long Leg Size Wt. Lbs. T1 40 5'-3" 33" V. #6 316 T2 56 4'- 27" H. #6 364 28 7'-0" Straight #6 295 T4 16 4'-5" 33" V. #6 107 N1 1 110" Welded Wire Fabric 2" x 2" 12 Ga. Min. 3 FOR REFERENCE ONLY MH 335 UGS MH 22 7' x 7' x 7' Manhole Traffic Loading SCE Public

Figure MH 13: 7' x 7' x 7' Manhole Traffic Loading Wall Notes: 1. All side steel clear from outside surface. B 3" Section B-B 8'- 7'-0" 13 Spaces 6" O.C. Vent When Required Wall Table MH 15: Reinforcing Schedule 7' x 7' x 7' Manhole Traffic Loading Wall Mark Quantity Length Long Leg Size Wt. Lbs. 56 7'-0" Straight #3 148 20 7'-0" Straight #3 53 20 2'-10" 17" H. #3 22 6" 4 Spaces 1 O.C. 7'-0" 8'-10" FOR REFERENCE ONLY 3" 12" 6" B 7' x 7' x 7' Manhole Traffic Loading SCE Public UGS MH 335 MH 23

Figure MH 14: 7' x 7' x 7' Manhole Traffic Loading Floor 10" C 3" 6 Spaces 6" O.C. Section C-C 8'- 7'-0" 3" Floor Plan Table MH 16: Reinforcing Schedule 7' x 7' x 7' Manhole Traffic Loading Floor Mark Quantity Length Long Leg Size Wt. Lbs. 56 5'- 33" H. #6 449 56 4'- 27" H. #6 364 32 7'-0" Straight #6 337 Notes: 1. All floor and roof steel 2" minimum clear from outside surfaces. All side steel minimum clear from outside surfaces. AC 710 FOR REFERENCE ONLY C 13 Spaces 6" O.C. 3" 3" MH 335 UGS MH 24 7' x 7' x 7' Manhole Traffic Loading SCE Public

MH 340 6' x 10' x 7' Manhole Traffic Heavy Loading Scope MH 340.1 6' x 10' x 7' Manhole Traffic Heavy Loading Figure MH 15: 6' x 10' x 7' Manhole Traffic Heavy Loading A 15" 15" 2" 15" 15" 2" T14 C T4 T5 T2 T6 T1 B T9 T8 2'-7" 2'-0" 6" 6" 2'0" T12 6'-3" 5'- 11 Spaces 6" T10 T11 2" 4 Spaces 10" 15" 10 Spaces 6" Bottom Steel Top Steel 11'- 10'-0" Plan B See MH 350 (page MH-29) Section A-A Figure MH 15.1 Plan and Section A-A 6" 12" 6" 2'-0" 2'-11" Neck Welded Wire Fabric - N1 2 30" Min. T14 3 Spaces 15" 7'-0" T13 T14 A T13 8'-10" Excavation 9'-10" Minimum FOR REFERENCE ONLY 9" 9" Sump 45 12" 2 Spaces 12" 6" 10" 1 Min. C 6' x 10' x 7' Manhole Traffic Heavy Loading SCE Public UGS MH 340 MH 25

9" 9" N1 1" CL T10, 11, 12, 13, and 14 3-1/2" CL Slope Floor to Sump Sump 45 Section B-B Figure MH 15.2 Section B-B and Section C-C Notes: 1. Refer to MH 300 (page MH-1) for reference drawing giving installation details, schedules, and general requirements for structures and accessories. 2. For total quantities of steel, castings, and related foundry items, see Summary Sheet for each set of working drawings. 3. See working drawings for additional neck, conduit bank, etc. Table MH 17: List of Materials 6' x 10' x 7' Manhole Traffic Heavy Loading Quantity T13, 14 3 Spaces 15" 25 Spaces 12" 6" Sump Reinforcing Symm. Abt. 11'- Description 1 Only 26 Manhole Casting 9.8 Cu. Yds. Concrete As Detailed Pull Eyes B9 3 0 2'-0" Section C-C B6 B4 B5 B7 2 B8 8 Spaces 7" 7' 2 Spaces 1 FOR REFERENCE ONLY 1 9" 9" MH 340 UGS MH 26 6' x 10' x 7' Manhole Traffic Heavy Loading SCE Public

Table MH 18: Reinforcing Schedule6' x 10' x 7' Manhole Traffic Heavy Loading Mark Quantity Type Size Total Length Wt. Lbs. Notes: 1. 23.12 Cu. Yds. Excavation 2. 820.9 Lbs. Reinforcing Steel T1 4 Straight 5/ Dia. 6'- 26.4 T2 2 Straight 5/ Dia. 5'-6" 11.5 2 Straight 5/ Dia. 4'-3" 3.7 T4 2 Straight 5/ Dia. 3'-10" 8.0 T5 2 Straight 5/ Dia. 3'-0" 6.3 T6 2 Straight 1/2" Dia. 10'- 14.3 T7 2 Straight 1/2" Dia. 8'- 11.1 T8 1 Straight 1/2" Dia. 5'-6" 3.7 T9 1 Straight 1/2" Dia. 3'-2" 2.1 T10 1 1/2" Dia. 3'-6" 2.4 T11 2 3/ Dia. 4'-2" 12.5 T12 2 1/2" Dia. 4'-0" 5.4 T13 18 3/ Dia. 5'-6" 148.8 T14 26 1/2" Dia. 5'-0" 85.6 N1 1 1'-0" 1'-2" 1'-6" Welded Wire Fabric 12 G.A. 2" x 2" Mesh (Min.) 1' x 13' Normal 12 1/2" Dia. 10'- 85.5 45 7 10'- 1/2" Dia. 15'- 71.5 29 Straight 1/2" Dia. 8'-1" 152.0 1 1/2" Dia. 4'- 2.9 2'- 4 1/2" Dia. 11'- 31.2 2 1/2" Dia. 11'-0" 14.7 B4 2 1/2" Dia. 10'-5" 13.2 B5 2 1/2" Dia. 9'-10" 13.1 B6 2 1/2" Dia. 9'-3" 12.4 B7 2 1/2" Dia. 8'- 11.6 B8 2 1/2" Dia. 8'-1" 10.7 1'-10" 3'-0" 3'-0" 2'-5" 6'-0" 6'- 6'-0" 5'-5" 4'-10" 4'-3" 3'- 3'-1" 45 2'- FOR REFERENCE ONLY B9 1 1/2" Dia. 8'-5" 5.6 0 1 1/2" Dia. 11'-5" 7.6 1 1 1/2" Dia. 14'-5" 9.6 2 1 1/2" Dia. 15'- 10.5 3 1 1/2" Dia. 6'-6" 4.6 3'-5" 6'-5" 9'-5" 10'- 4'-0" 4.7 6' x 10' x 7' Manhole Traffic Heavy Loading SCE Public UGS MH 340 MH 27

MH 350 Manhole Neck Details 27" Opening Scope MH 350.1 Manhole Neck Details 27" Opening Figure MH 16: Manhole Neck Details 27" Opening Color top surface to match surrounding pavement Drop thru clean out holes below each cover bolt 1" 2" FC 620 Manhole Cover In non-traffic installations neck may be bevelled to allow matching of existing pavement 12" min. below flow line of gutter 13-1/2" 10" 12" 2" Min. Varies 13-1/2" 15-1/2" See AC 740 for Ladder Installation Half Elevation Normal Neck (Height 2 or Less) Half Elevation Extended Neck (Height in Excess of 2) For cold joint use 2" x key and two coats of Sika Seal 6" Overlap of Reinforcing Cover Bolts (With Drop Thru Holes) 4 Required 43" Sq. 47" Sq. Anchor Bolts 4 Required Half Plan Normal Neck (Height 2 or Less) Half Plan Extended Neck (Height in Excess of 2) Notes: 1. Reinforcing: No. 3 rebar on 12" centers or 4 x 4-10/10 WWF minimum concrete coverage shall be 2". Manhole Neck Details 27" Opening SCE Public UGS MH 350 MH 29

2. Concrete: per GI 020. 3. variations may be allowed precasters to accommodate manufacturing processes. 4. Use 30" round opening if specified on substructure drawing MH 350 UGS MH 30 Manhole Neck Details 27" Opening SCE Public