Compact Reverse Transmitters with DFB or CWDM Lasers

Similar documents
Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

CXE880 FIBRE OPTIC NODE

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

Compact Node Optoelectronics

CXE880 FIBRE OPTIC NODE

CXE880 FIBRE OPTIC NODE

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Cisco Prisma II 1.2 GHz High Density Long Reach Multiwave Transmitter

TELESTE AC NODE SPECIFIC MODULES

OPTICAL NODE TRUNK & DISTRIBUTION

CXE880 FIBRE OPTIC NODE

Compact Nodes and 90071

GainStar 1 GHz Node with 42/54 MHz Split

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

GainMaker High Output Node 5-40/ MHz

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES

GainMaker High Output 4-Port Node

ODN4P. Optical Distribution Node, Four Ports. About the Product

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split

AC500 AMPLIFIER PLATFORM

GainMaker Optoelectronic Node 1 GHz with 40/52 MHz Split and RF Redundancy

Cisco Prisma Optical Passive Components

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

Cisco 1218 MHz GainMaker High-Gain Balanced Triple System Amplifier

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

Cisco 1218 MHz GainMaker High Gain Dual (HGD) System Amplifier

Opti Max Optical Node Series

MODEL BTN GHz OPTICAL NODE STARLINE SERIES

Prisma II Multi-Wavelength High Density Transmitter

CWDM Coaxial DFB-LD Module for CATV Return-path

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

ACE8 1.2 GHZ INTELLIGENT OPTICAL NODE

Cisco 1.2GHz GainMaker Line Extender (GMLE)

product overview optical nodes

End of Life. Headend Optics Platform (HLP) SPL7210S/A. HL2 Series SUPRALink High Density DWDM Transmitter FEATURES PRODUCT OVERVIEW. arris.

Prisma II 1 GHz SuperQAM Transmitter

1550nm external modulated optical transmitter operating manual

1935 F/R/W Coaxial DFB Laser Diode

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

1955 F/R/W Coaxial DFB Laser Diode

Prisma II 1 GHz SuperQAM Full Spectrum Transmitter

AC800 FIBRE OPTIC NODE

Prisma II 1310 nm High Density Transmitter and Host Module

AC8800 INTELLIGENT FIBRE OPTIC PLATFORM

Model 1955F/R/W Coaxial DFB Laser Diode

AC8000 FIBRE OPTIC PLATFORM

Prisma II Optical Receivers

TELESTE AC AMPLIFIER MODULES

End of Life. Optical Node Series (HL2) HLN3142C. HL2 Series PWRBlazer II Optical Nodes FEATURES PRODUCT OVERVIEW. arris.com

Prisma II 1310 nm High Density Transmitter and Host Module

SCTE. San Diego Chapter March 19, 2014

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

1933 F/R/W Coaxial DFB Laser Diode

2016 Spring Technical Forum Proceedings

Model 6940 Collector/Terminator Three Port Unbalanced Optoelectronic Node 870 MHz with 65/86 MHz Split

Headend Optics Platform (CH3000)

Model 6940 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

Prisma II 1 GHz 1550 nm Transmitters

DVO902 E/S CATV FIBRE TRANSMITTER

70/140 MHz IF Fiber Optic Link

CWDM Cisco CWDM wavelengths (nm)

Digital Return System

ULTRA BROADBAND RF over FIBER Transceiver OZ1606 Series Premium Grade 6 GHz

Description. Applications CATV Return-path Analog transmission. DFB-1xxx-C5-2-A-xx-x-x-xx REV 014 APPLIED OPTOELECTRONICS, INC.

1752A 1550 nm DOCSIS 3.1 DWDM DFB Laser Module

AC3000 INTELLIGENT BROADBAND AMPLIFIER

7820R Optical Receiver MHz RFoG Return Path

HDO905 CATV FIBRE TRANSMITTER

Mounting Instruction. Compact Mini EGC Amplifier and Application

Optical Transmitter RF-T860/24. Installation & Operation Manual. Caution

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

HDO772 C-BAND DWDM FIBRE TRANSMITTER

1622A/B CWDM DFB Laser Module

REV DESCRIPTION DATE APPROVED 1 Preliminary 06/04/2018 GJP/RAS 2 Add Low-Noise Configuration to the description 07/30/2018 RAS/GC

ModBox - Spectral Broadening Unit

CXE180 UNIVERSAL AMPLIFIER

HDO907 CATV FIBRE TRANSMITTER

Optical Delay Line Application Note

Digital Return System

7820C CATV Optical Receiver 200 MHz HFC Return Path

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

RF Solutions SW 15th Street Deerfield Beach, FL

Downstream signal path (values with diplex filters)

Cisco GainMaker High Output High Gain Balanced Triple 1 GHz System Amplifier 5-85/ MHz

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

CXE180 UNIVERSAL AMPLIFIER

WaveSmart Wave Division Multiplexing (WDM)

Miniature, Ruggedized, 20 GHz RF over Fiber Transmitter

1751A 1550 nm DWDM DFB Laser Module

ACE3 INTELLIGENT BROADBAND AMPLIFIER

Antenna Fiber Boxes. BROADY SOLUTIONS - Tel : +33 (0)

Transcription:

Data Sheet Compact Reverse Transmitters with DFB or CWDM Lasers Cisco Compact Nodes can be configured with a variety of optical reverse transmitters to provide flexibility for use in multiple applications. These reverse transmitters are plug-in modules that deliver a cost-effective, user-friendly solution for upstream transmission. The Compact Reverse Transmitters (Figure 1) are available with distributed feedback (DFB) or Coarse Wavelength Division Multiplexing (CWDM) lasers. All transmitters feature a built-in microprocessor and pilot tone for easy set-up of the reverse path. The pilot tone does not take up any reverse bandwidth as it is placed at 5 MHz. Moreover, placing the pilot tone at 5 MHz also makes the reverse transmitter interoperable with virtually all reverse receivers in the marketplace. If there is no modulation, the pilot tone serves as a quieting tone, which reduces spurious noise and improves overall noise performance with up to 15 db. All reverse transmitters have increased gain, which allows low reverse input levels at the node. The reverse transmitter can also run in burst mode which makes it possible to deploy Cisco Compact Nodes in a radio frequency over glass (RFOG) network. Reverse Transmitters and CWDM The reverse transmitters (Figure 2) are an integral part of the CWDM transport system making it possible for each fiber in a hybrid fiber-coaxial (HFC) network to support a sixteen-fold increase in the number of wavelengths available. The CWDM lasers offer two output powers, 3 dbm and 6 dbm. Figure 1. Reverse Transmitter 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 8

General Features Designed to operate within the Cisco Compact Nodes (A90100/A90300, A90200, A90201) Variable modulation depth (RF drive level) promotes superior link optimization RF input test point 5-MHz pilot tone for easy setup Multiple setup and control options Local control with front panel or Cisco Handheld Programmer Terminal Model 91200 Advanced element management (status monitoring and control) interface Nonvolatile storage of preset operating parameters Remote optical modulation index (OMI) setting, when supported by node Burst mode for interoperability in RFoG 0 dbm DFB 3 dbm and 6 dbm, DFB available in 16 CWDM wavelengths Uncooled DFB lasers with Isolator for exceptional performance and low power consumption Figure 2. Reverse Transmitter Block Diagram Noise Power Ratio (NPR) Performance Figures 3 through 5 show the NPR performance of the Compact Reverse Transmitter. Test condition: Prisma II Reverse Optical Receiver (part number: P2-RRX-STD), 10 db optic link (20 km glass, plus passive loss), Cisco Compact EGC Fiber Deep Node A90100 in default setting, with reverse transmitter attenuator at 10dB and room temperature. 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 2 of 8

Figure 3. NPR Performance for 5 to 65 MHz in Normal Mode Figure 4. NPR Performance for 5 to 204 MHz in Normal Mode Figure 5. NPR Performance for 5 to 65 MHz in Burst Mode 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 3 of 8

Node Correction Factor A Cisco A90100 Node is used in the NPR tests in figures 3 through 5. For the nodes listed in Table 1, the X-axis in the three figures, which indicates input power per hertz, must move to the left by the correction factor also listed in Table 1. The node is set to its default configuration and tested with a reverse jumper in the diplexer slot. Table 1. Node Correction Factor Cisco Node A90201 Correction Factor (db) 1 (gain) A90100/A90300 0 A90200 2.2 (loss) Example: Node type A90200 has a correction factor of 2.2 db. From the NPR-curve (Figure 3), a 0 dbm DFB laser (part number: CMPT-RTX-0-13) will have the best NPR performance (47.5dB) at an input of 53 dbmv/hz. For Node type A90200 the required input power at the port will need to increase to 50.8 dbmv/hz (= -53 ( 2.2)) to achieve the best NPR performance. NPR Performance Descriptions The NPR performance plots contained in this document depict the NPR performance on a reference 10 db fiber optic link. With other link losses, the following items vary from that shown on the reference 10 db link plots. NPR dynamic range for a given minimum NPR performance (Carrier to Noise ratio) NPR value for a given transmitter RF input level To determine an NPR dynamic range for a different link loss: Add (or subtract) the correction factor from Table 2. Associated with the desired link loss to (or from) the dynamic range shown on the reference 10 db link NPR plots. Note that the associated increase (or decrease) in dynamic range affects only the left side of the NPR curve (minimum RF input side), since that is the portion of the curve affected by changes to the traditional noise sources associated with optical link. To determine an NPR value for a different link loss: Add (or subtract) the correction factor from Table 2 associated with the desired link loss to (or from) the NPR value shown on the 10 db link NPR plot for a given RF input level. Again, only the NPR values on the left side of the NPR curve (prepeak values) are to be adjusted. The NPR values and slope associated with the right side of the NPR curve (post peak values) are primarily due to laser clipping at high RF input levels. Therefore, they do not vary appreciably with link loss, but only with the channel load. Table 2 lists link loss correction factors. Table 2. Link Loss Correction Factors for 5 to 65 MHz Loss Correction Factor (db) Optical Link loss (db) Fiber Length (km) 0dBm DFB 3dBm DFB/CWDM 6dBm CWDM 2 0 6 3.25 N/A 6 12.5 1 1 1 8 12.5 0.5 0.5 0.9 9 20 0 0 0 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 8

Loss Correction Factor (db) Optical Link loss (db) Fiber Length (km) 0dBm DFB 3dBm DFB/CWDM 6dBm CWDM 10 20 0 0 0 12 20 1 1 1 15 20 3.5 3 1.6 18 20 8 7 4.5 20 20 N/A 10 6.5 Table 3. Link Loss Correction Factors for 5 to 204 MHz Optical Link loss (db) Fiber Length (km) Loss Correction Factor (db) 0dBm DFB 3dBm DFB/CWDM 6dBm CWDM 2 0 5 2,4 NA 6 12.5 3 1 1, 5 8 12.5 2, 5 0, 5 1 9 20 0 0 0 10 20 0 0 0 12 20-1 -1, 5-0, 5 15 20-3 -3, 5-2 18 20-6 -6-3, 5 20 20-8, 5-8 -5, 5 Example: Figure 6 shows how dynamic range (for NPR of 30 db) of a 0 dbm DFB-laser will be influenced for 6 db link loss and 15 db link loss for 5 to 65 MHz. Figure 6. Example of NPR Performance 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 8

Product Specifications This section lists product specifications for. Table 4. Specifications Optical Performance Unit DFB laser CWDM laser 3 dbm CWDM laser 6 dbm Note Wavelength nm 1310 ±30 1270, 1290, 1310, 1330, 1350, 1370, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 Connector options See Ordering Information Output power dbm/db 0 ±0.5 or 3 ±0.5 Electrical Performance Frequency range MHz 5 to 300 Tolerance: ±3 (CWDM) 3 ±0.5 6 ±0.5 1270, 1290, 1310, 1330, 1350, 1370, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 Tolerance: ±3 (CWDM) At 25 C ambient temperature Input level (normal mode) dbµv 60 to 70 At module input @ 10% OMI Test point db -10 Input Return Loss 5 300 MHz db 20 At 40 MHz decreasing with 1.5 db/octave and module on Spurious Noise Level Carrier on/pilot on dbc 50 55 60 Carrier off/pilot on dbc 50 55 55 Carrier off/pilot off dbc 33 33 33 Flatness for 5 204 MHz db ±0.5 ±0.7 for 5 to 300 MHz Power consumption W 2.25 2.25 2.50 Measured in node Burst Mode Standard ANSI/SCTE 174 Transmitter input level (burst mode) Laser rise time Laser fall time Pilot tone Frequency MHz 5 dbµv 82 For 10% OMI with 10 db internal attenuation; recommended symbol rate = 5.12 MS/s µs µs < 1.3 < 1.6 Level dbµv 35 to 45 Environmental Node operating Temperature range Mechanical C 15 to +55 Dimensions (H x W x D) mm 22 x 69 x 77 Weight g 105 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 8

Optical Performance Unit DFB laser CWDM laser 3 dbm CWDM laser 6 dbm Note Element Management Parameters - Alarms Alarms from reverse transmitter Module OK Laser aging Laser failure Element Management Parameters Status information (depending on node) Factory data Wavelength Output power Frequency range Laser bias current Element Management Parameters - Settings OMI setting (internal attenuator 0 10dB) Pilot tone level Transmitter on/off Pilot tone on/off Ordering Information Table 5 lists ordering information for reverse transmitters. Table 6 provides ordering information for required accessories, which must be ordered separately. To place an order, visit the Cisco Ordering Home Page. Table 5. Ordering Information Reverse DFB Transmitters Part Number 0 dbm, 1310 nm, DFB laser, pigtail with SA/APC connector CMPT-RTX-0-13 3 dbm, 1310 nm, DFB laser, pigtail SA/APC connector CMPT-RTX-3-13 Reverse CWDM Transmitters Part Number 3 dbm, 1270 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1270 3 dbm, 1290 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1290 3 dbm, 1310 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1310 3 dbm, 1330 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1330 3 dbm, 1350 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1350 3 dbm, 1370 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1370 3 dbm, 1430 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1430 3 dbm, 1450 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1450 3 dbm, 1470 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1470 3 dbm, 1490 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1490 3 dbm, 1510 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1510 3 dbm, 1530 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1530 3 dbm, 1550 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1550 3 dbm, 1570 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1570 3 dbm, 1590 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1590 3 dbm, 1610 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-3-1610 6 dbm, 1270 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1270 6 dbm, 1290 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1290 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 8

6 dbm, 1310 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1310 6 dbm, 1330 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1330 6 dbm, 1350 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1350 6 dbm, 1370 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1370 6 dbm, 1430 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1430 6 dbm, 1450 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1450 6 dbm, 1470 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1470 6 dbm, 1490 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1490 6 dbm, 1510 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1510 6 dbm, 1530 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1530 6 dbm, 1550 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1550 6 dbm, 1570 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1570 6 dbm, 1590 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1590 6 dbm, 1610 nm, CWDM laser, pigtail SA/APC connector CMPT-RTX-6-1610 Table 6. Required Accessories Accessories Part Number One adapter is required for each optical connection. Optical connector on the reverse transmitter module is SC/APC. Adapter SC/APC to SC/APC A90540.1088 Cisco Capital Financing to Help You Achieve Your Objectives Cisco Capital can help you acquire the technology you need to achieve your objectives and stay competitive. We can help you reduce CapEx. Accelerate your growth. Optimize your investment dollars and ROI. Cisco Capital financing gives you flexibility in acquiring hardware, software, services, and complementary third-party equipment. And there s just one predictable payment. Cisco Capital is available in more than 100 countries. Learn more. For More Information To learn more about Cisco Compact Reverse Transmitters, visit: http://www.cisco.com/c/en/us/products/video/compact-nodes/index.html Printed in USA C78-736197-01 09/16 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 8