Precision Thermistor Sensors

Similar documents
STANDARD RTD's INDEX

Configure-to-Order probes

Mineral-insulated resistance thermometers to EN

Ultra Precise Immersion RTD Sensors

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

4.00 ULTRASONIC ANALYZER

Screw-in resistance thermometers with plug connector

Digital conductivity transmitter

Valve Island with Electronic I/O

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

Non-Submersible Industrial Pressure Transducer

Fiber Optic Cables Plastic Fiber Optic Cables Glass Fiber Optic Cables

ADVANCED GROUP. Pee-Series Series 12 KVDC. Introduction. Introduction

Solid State Pressure Sensors D8M

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Rod probe With coaxial tube reference probe

mass flowmeter for compressed air

Release A Member of the

Resistance thermometers for process technology

Additel 875 Series Dry Well Calibrators

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

ORDER CODES 1-2(A) 1-3 R5T185L Single Platinum RTD Elements 1-2 Available Sheath Diameters 316SS 1-4 Length CODE TEMPERATURE

9.1 Plastic Fiber Optic Cables. 9.2 Glass Fiber Optic Cables. Volume 8 Sensing Solutions CA E August

MODEL S15 Incremental Optical Rotary Encoder

Thermocouples. Table of Contents. Industrial (A-2) Smart Model 1100 (A-26) Smart with Leads Model 1200 (A-27) Wire (A-32)...

JCN cables. The. splice is an

ph or ORP Transmitter

The transducer component converts the measured signal and displays the actual value.

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection

Pre-Calibrated Models

L = 30 mm L = 150 mm T 90

Load Cell Accessories and Services

Screw-in resistance thermometers with terminal head Form B

SRS SEALED ROTARY SENSORS

Sitron Capacitive Level Sensors

MIST SANITARY SERIES TM

Conductivity Analyzer

XPC10 High temperature miniature pressure sensor

HOBO FlexSmart Logger-New! Onset s new HOBO FlexSmart Logger

LBB Series Ultra-Precision Gage Heads

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Magnetic-Inductive flow Meter fmi

TECHNICAL DATA ELECTRO CHEMISTRY DIFFERENTIAL PH AND ORP. phd sc Digital Diferrential PH and ORP Sensors

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

AtlasScientific ALL WEATHER TEMPERATURE TURE SENSOR ENV-TMP. Biology Technology. Typical Applications:

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

Magnum TM Cartridge Heaters

Pacific Antenna RF Probe assembly

Micro-Change. Cordset Family

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

ENVIRONMENTAL. Operating Temperature: -40ºC to +130ºC. Wire Size. Code Accepted Max Wire Gauge Insulation AWG Solid or Stranded

9.2. Fiber Optic Cables.

Commercial Micro-D Subminiature I/O Products

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

B Operating Instructions V1.00/EN/

Resistance thermometer Model TR31, miniature design

Thin Film Deposition

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

AD5X. Low Cost HF Antennas & Accessories. Phil Salas - AD5X Phil Salas AD5X. Richardson, Texas

Torque Sensor Accessories and Services

Thin Film Deposition

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Model 25B-F/S/L Solid Shaft Low Line Incremental Optical Rotary Encoder

SureGrip TM. XWWarning

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

PH METER OPERATION MANUAL. Model : PH-208

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Ultrasonic level transmitter, non-contact

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Heat-Shrinkable Tubing

DIGITAL OXYGEN METER. Model : DO-5510

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

TEMPERATURE PROBE. Temperature probe. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Application: NiCr-Ni (Type K)

Airflow: up to 28 CFM, 3000 Pa Air Pressure

1) What meter do I need in this application?

Measuring and Controlling Unit Multronic OC

Fluke 712B and 714B Temperature Calibrators

NEUROLOGIC RESEARCH CORPORATION

RF Microwave Standard Assemblies

Resistance Thermometers Model Series TR7X0, Sheathed Design

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Thru Wall Floor Seals For New Installation

AMPLIMITE Cable Connectors and Shielding Hardware Kits

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

SECTION AUTOMATED STORMWATER SAMPLING SYSTEM

Miniature resistance thermometer Model TR33, thread-mounted

LGH High Voltage Connectors

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

User s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

ULTRASONIC FLOW METER FT101

Lengths [7] Ø.50 [13] [7] [13]

General Information...SA1-SA4

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Transcription:

Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings U Available with a Resistance of 2252 Ω at 25 C (Thermistor Curve #44004) U 3 m (10 ) PVC Insulated Cable and Phone Plug Connector Standard U Max Temperature 25.4 (1) ON-401-PP Resistance Interchangeability Temperature Cable Cable Model No. @ 25 C @ 0 to 70 C Rating Length Termination ON-401-PP 2252 Ω ±0.1 C 3 m (10') Phone plug Notes: For additional cable length, add required length (in inches) to end of the model number for an additional cost per foot. Ordering Example: ON-401-PP, vinyl coated thermistor sensor, 2252 Ω resistance at 25 C, ±0.1 C interchangeability from 0 to 70 C (32 to 158 F), supplied with 3 m (10') of PVC insulated and jacketed cable with a phone plug connector standard. 3.6 (0.1406) Dia. 7.9 (0.3125) max ON-401-PP-V 6.4 ( 1 4 ) max Resistance Interchangeability Temperature Cable Cable Model No. @ 25 C @ 0 to 70 C Rating Length Termination ON-401-PP-V 2252 Ω ±0.1 C 3 m (10') Phone plug Notes: For additional cable length, add required length (in inches) to end of the model number for an additional cost per foot. Ordering Example: ON-401-PP-V, soft flexible vinyl tipped thermistor sensor, 2252 Ω resistance at 25 C, ±0.1 C interchangeability from 0 to 70 C (32 to 158 F), supplied with 3 m (10') of PVC insulated and jacketed cable with a phone plug connector standard. ON-402-PP 2.4 ( 3 32 ) dia. 6.4 ( 1 4 ) dia. 3.2 ( 1 8 ) dia. Resistance Interchangeability Temperature Cable Cable Model No. @ 25 C @ 0 to 70 C Rating Length Termination ON-402-PP 2252 Ω ±0.1 C 3 m (10') Phone plug Ordering Example: ON-402-PP, vinyl tipped thermistor sensor, 2252 Ω resistance at 25 C, ±0.1 C interchangeability from 0 to 70 C (32 to 158 F), supplied with 3 m (10') of PVC insulated and jacketed cable with a phone plug connector standard. D-23

Tubular Thermistor Sensors For Immersion Temperature Measurements 32 (1 1 4) 27 (1 1 8) 114 (4 1 2) 6.3 ( 1 4) diameter 3.2 ( 1 8) diameter ON-403-PP ON-403-PP U 300 Series Stainless Steel Probe for Rugged-Duty Liquid Immersion Use U Probe is Immersible to End of Transition U Provided with 3 m (10') of PVC Cable and Phone Plug Connector Resistance Interchangeability Cable Model Number @ 25 C @ 0 to 70 C Termination ON-403-PP 2252 Ω @ 25 C ±0.1 C Phone plug Notes: For additional cable length, add required length (in inches) to end of the model number for an additional cost. Ordering Examples: ON-403-PP, tubular stainless steel immersion thermistor sensor, 2252 Ω at 25 C, interchangeability is ±0.1 C, 3 m (10') of PVC insulated and jacketed cable and phone plug connector. ON-403-PP-240, tubular stainless steel immersion thermistor sensor, 2252 Ω at 25 C, interchangeability is ±0.1 C, 6 m (20') of PVC insulated and jacketed cable with phone plug. Model Number HH42 SSLK-14-18 with RS232 communications 1 4" tube OD, 1 8 NPT, 316 SS compression fitting D-19

Tubular Glass Thermistor Sensors For Immersion Temperature Measurements Stainlesssteeltransition fitting. 127 (5) 4.8 ( 3 16 ) diameter ON-404-PP ON-404-PP U Chemically Inert for Liquid Immersion Use U Can Be Used for Thermal Titration Studies and Measurement of Freezing Points U 127 mm (5") L Pyrex Probe and 3 m (10') of PVC Cable Insulated and Jacketed Cable with Phone Plug Connector Standard Resistance Interchangeability Cable Model No. @ 25 C @ 0 to 70 C Termination ON-404-PP 2252 Ω ±0.1 C Phone plug Model No. HH42 with RS232 communications Ordering Example: ON-404-PP, tubular glass immersion thermistor sensor, 2252 Ω at 25 C, interchangeability of ±0.1 C, 3 m (10 ) of PVC insulated and jacketed cable and phone plug connector. D-25

Precision Thermistor Sensor For Air Temperature Measurements 3 m (10') L vinyl insulated, shielded, vinyl jacketed cable included. ON 405 and 406 supplied with 300 mm (12") of cable and phone plug. 32 (1 1 4) 300 Series Stainless Steel Housing 32 (1 1 4) Plastic Housing for High Humidity Applications 13 ( 1 2) 16 ( 5 8) 13 ( 1 2) 13 ( 1 2) 16 ( 5 8) 13 ( 1 2) D ON-905-44004 shown smaller than actual size. ON-906-44004 shown smaller than actual size. ON-905 and ON-906 Series U Ideal for Measuring Air Temperatures in Laboratories and Laminar Flow Systems U Metal or Plastic Cage Provides Protection for Thermistor Sensor While Leaving it Open to the Air Flow U Available in 5 Resistance Curves U Thermistors are Epoxy Coated and Extend Into the Airflow U Maximum Temperature Model Resistance Interchangeability Maximum Cable Cable Number @ 25 C @ 0 to 70 C Temperature Length Termination ON-405-PP 2252 Ω ±0.1 C 3 m (10') Phone plug ON-406-PP 2252 Ω ±0.1 C 3 m (10') Phone plug ON-905-44004 2252 Ω ±0.2 C 300 mm (12") Stripped ON-905-44005 3000 Ω ±0.2 C 300 mm (12") Stripped ON-905-44007 5000 Ω ±0.2 C 300 mm (12") Stripped ON-905-44006 10000 Ω ±0.2 C 300 mm (12") Stripped ON-905-44008 30000Ω ±0.2 C 300 mm (12") Stripped ON-906-44004 2252 Ω ±0.2 C 300 mm (12") Stripped ON-906-44005 3000 Ω ±0.2 C 300 mm (12") Stripped ON-906-44007 5000 Ω ±0.2 C 300 mm (12") Stripped ON-906-44006 10000 Ω ±0.2 C 300 mm (12") Stripped ON-906-44008 30000 Ω ±0.2 C 300 mm (12") Stripped Notes: For additional cable length, add required length (in inches) to end of the model number for an additional cost. For a phone plug, add -PP to the model number for an additional cost. For tighter interchangeability, substitute the thermistor part number from the table below for an additional cost to the sensor price. Ordering Examples: ON-905-44004-36-PP, air temperature sensor with a steel cage and a resistance of 2252 Ω at 25 C, interchangeability of ±0.2 C, 36 of cable and a phone plug connector. ON-905-44034-36-PP, air temperature thermistor sensor with steel cage and a resistance of 5000 Ω at 25 C, interchangeability of ±0.1 C, 36" of cable and a phone plug connector. Optional Thermistors Resistance Maximum Storage and Working Model @ 25 C Working Interchangeability Temp for Best Number (Ω) Temperature @ 0 to 70 C Stability 44033 2252 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44030 3000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44034 5000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44031 10,000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44032 30,000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) D-26

Banjo Style Thermistor Sensor ON-408-PP shown actual size. 92.7 (3 5 8 ) 10.3 ( 13 32 ) dia. x 2 ( 5 64 ) thick 32 (1 1 2 ) 17 gage extension. Strain relief spring. Shown actual size. ON-408-PP U 300 Series Stainless Steel, Hermitically Sealed Unit U Extremely Sensitive Sensor with Thin Cross- Section Tip Combined and Ultra Small Diameter Extension Sheath U Measures Water Baths, and Air and Surface Temperatures U 3 m (10') PVC Insulated and Jacketed Cable with Phone Plug Connector Standard Resistance Interchangeability Maximum Cable Cable Model No. @ 25 C @ 0 to 70 C Temperature Length Termination ON-408-PP 2252 Ω ±0.1 C 3 m (10') Phone plug Model No. 865F Thermistor meter; in 0.1 F resolution mode, -70.0 to 40.1 F, -40.0 to 199.9 F DP25-TH-A Thermistor input meter/controller with analog output Ordering Example: ON-408-PP, banjo style thermistor sensor, 2252 Ω at 25 C, interchangeability of ±0. 1 C, 3 m (10') of cable with a phone plug connector. D-37

Precision Thermistor Sensor For Surface Temperature Measurements ON-909 Series 13 ( 1 2) Min 0.44" Dia. ON-909-44004 Sensor Diameter (See Table Below) D ON-409-PP supplied with 3 m (10') of cable and phone plug. Dimensions: mm (inch) U Epoxy Encapsulated Thermistor Contained in Stamped, 300 Series SS Housing U Construction Provides Maximum Surface Contact U 26 AWG Stranded PFA Insulated and Jacketed Cable (See Table for Length) Model Resistance Interchangeability Max Tip Diameter Cable Cable Number @ 25 C @ 0 to 70 C Temp (inch) Length Termination ON-409-PP 2252 Ω ±0.1 C 0.44" 3 m (10') Phone plug ON-909-44004 2252 Ω ±0.2 C 0.38" 300 mm (12") Stripped ON-909-44005 3000 Ω ±0.2 C 0.38" 300 mm (12") Stripped ON-909-44007 5000 Ω ±0.2 C 0.38" 300 mm (12") Stripped ON-909-44006 10000 Ω ±0.2 C 0.38" 300 mm (12") Stripped ON-909-44008 30000 Ω ±0.2 C 0.38" 300 mm (12") Stripped ON-909-44004-40 2252 Ω ±0.2 C 0.38" 1 m (40") Stripped ON-909-44005-40 3000 Ω ±0.2 C 0.38" 1 m (40") Stripped ON-909-44007-40 5000 Ω ±0.2 C 0.38" 1 m (40") Stripped ON-909-44006-40 10000 Ω ±0.2 C 0.38" 1 m (40") Stripped ON-909-44008-40 30000 Ω ±0.2 C 0.38" 1 m (40") Stripped Notes: For additional cable length, add required length (in inches) to end of the model number for additional cost. For a phone plug, add -PP to the model number for additional cost. For tighter interchangeability, substitute the thermistor part number from the table below and add the price listed to the sensor price. Ordering Examples: ON-909-44004-40-PP, surface thermistor sensor with a resistance of 2252 Ω at 25 C and an interchangeability of ±0.2 C, 1 m (40") of cable and a phone plug connector. ON-909-44032-40-PP, surface thermistor sensor with a resistance of 30000 Ω at 25 C and an interchangeability of ±0.1 C, 1 m (40") of cable and a phone plug connector. Optional Thermistors Resistance Maximum Storage and Working Model @ 25 C Working Interchangeability Temp for Best Number (Ω) Temp @ 0 to 70 C Stability 44033 2252 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44030 3000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44034 5000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44031 10,000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) 44032 30,000 75 C (165 F) ±0.1 C -80 to 75 C (-110 to 165 F) D-20 U Ideally Suited for Applications Such as Determining Heat Loss, Compressor Efficiency and Measuring Manifold or Bearing Temperature U Max Temperature

Tubular Thermistor Sensors For Immersion Temperature Measurements 14.287 ( 9 16) 114 (4.50) D 1 8 NPT 3.2 ( 1 8) diameter ON-410-PP ON-410-PP U Threaded Fitting Provides 1 8 NPT Thread for Installation in Pipes or Closed Vessels U Can Be Used in Liquid Immersion and Pressurized Applications U Available in 5 Resistance Values To Fit Your Instrumentation Needs U Maximum Temperature U 3 m (10') PVC Insulated and Jacketed Cable with Phone Plug Standard Model Resistance Interchangeability Maximum Cable Cable Number @ 25 C @ 0 to 70 C Temperature Length Termination ON-410-PP 2252 Ω ±0.1 C 3 m (10') Phone plug Notes: For additional cable length, add required length (in inches) to end of the model number for an additional cost. Ordering Example: ON-410-PP, tubular immersion sensor, 2252 Ω resistance at 25 C, ±0.10 C interchangeability from 0 to 70 C (32 to 158 F), supplied with 3 m (10') of PVC insulated and jacketed cable with a phone plug connector standard. Model Number CN1501-TH-1 Controller with 240 Vac power DP25-TH Precision panel meter/controller HH42 with RS232 communications HH83 Thermometer/data logger 5831 Benchtop thermometer OM-SQ2010 Data logger D-34